ART

SuperMark 1.5T
ART + APEX Platform
MRI System Configuration

Shenzhen Anke High-tech Co., Ltd.


Ver: MRSM15-2108
Shenzhen Anke High-tech Co., Ltd.

SuperMark 1.5T standard configuration

1. Main components and accessories


No. Descriptions Quantity

1.1 Main imaging system 1 set

1.2 Magnet system 1 set

1.3 Standard cover 1 set

1.4 Gradient system 1 set

1.5 16ch digital spectrometer system 1 set

1.6 RF transmitting system 1 set

1.7 16ch-ART RF receiving system 1 set

1.8 Patient table and control system 1 set

1.9 Patient communication system 1 set

1.10 Patient supervision TV system (CCTV) 1 set

1.11 Physiological gating system 1 set

1.12 Console system 1 set

1.13 Console table and chair 1 set

1.14 Dedicated isolated regulation power supply 1 set

1.15 Electronic cabinet (With standard PDU inside) 1 set

1.16 1KVA UPS (For console system only) 1 set

1.17 Water cooling system 1 set

1.18 Standard RF shielding cage 1 set

1.19 Accessories 1 set

1.20 Standard software package 1 set

www.anke.com 1
Shenzhen Anke High-tech Co., Ltd.

 Neurology imaging suite


 Body imaging suite
 Orthopedics imaging suite
 Oncology imaging suite
 Angiography imaging suite
 Breast imaging suite
 Pediatric imaging suite
 APEX intelligent operation suite
 Soft-Sound silent scanning suite
*To obtain more accurate image information, optional coils, optional accessories and
advanced post-processing software are required.

2. Standard RF coils
No. Descriptions Quantity

2.1 Transmitting & Receiving integrated body coil 1 set

2.2 Head/Neck coil – 18 1 set

2.3 Spine coil – 18 1 set

2.4 Body coil – 6 1 set

2.5 Large flex coil – 8 1 set

2.6 Small flex coil – 4 1 set

2.7 Knee coil – 8 1 set

2.8 Coil accessories 1 set

2.9 Standard coil cabinet 1 set

3. Standard scanning sequence


No. Descriptions

3.1 SE (Spin Echo)

3.2 FSE (Fast Spin Echo) 2D/3D

www.anke.com 2
Shenzhen Anke High-tech Co., Ltd.

SSFSE (Single Shot Fast Spin Echo) 2D/3D

3.3 DIXON (Water and Fat Separation Technology)

3.4 IR (Inversion Recovery)


STIR (Short Time Inversion Recovery)
FLAIR (Fluid Attenuated Inversion Recovery)
DIR (Dual Inversion Recovery) FSE

3.5 GRE (Gradient Echo) 2D/3D


Spoiled GRE (Spoiled Gradient Echo) 2D/3D
GREDE (Gradient Echo with Dual Echo) 2D
GREME (Gradient Echo with Multi Echo) 2D
TFE (Turbo Field Echo) 2D/3D
IRGRE (Inversion Recovery Gradient Echo) 3D
WEGRE (Water Excitation Gradient Echo) 3D
SSFP (Balanced steady state with free precession) 2D/3D
SSFPMP (Balanced Steady State with Free Precession with Multi Phase) 2D

3.6 TOF (Time of Flight) 2D/3D


PCMRA (Phase Contrast MR Angiography)
CEMRA (Contrast Enhanced MR Angiography)

3.7 EPI (Echo Planar Imaging)


SEEPI (Spin Echo Planar Imaging)
GREEPI (Gradient Echo Planar Imaging)
DWEPI (Diffusion Weighted Echo Planar Imaging)
DWEPIMS (Diffusion Weighted Echo Planar Imaging with Multi Shot)

4. Standard acquisition & reconstruction technology

Advanced neurology imaging

4.1 Single shot echo planar diffusion weighted imaging


Multi shot echo planar diffusion weighted imaging
Real-time ADC-mapping & eADC mapping

www.anke.com 3
Shenzhen Anke High-tech Co., Ltd.

Diffusion imaging distortion correction technology


Anisotropic imaging
3D iso-matrix imaging
SWI (Susceptibility Weighted Imaging)
APTI (Amide Proton Transfer Imaging)

Advanced body imaging

4.2 Dynamic imaging technology


SPAIR (Spectral Adiabatic Inversion Recovery) fat saturation technology
MRCP (Magnetic Resonance Cholangiopancreatography)
MRU (Magnetic Resonance Urography)
MRM (Magnetic Resonance Myelography)

Advanced orthopedics imaging

4.3 Multi-echo T2-weighted imaging technology


Phase multiple oversampling technology
Water excitation imaging
Off-center positions imaging
Fast water-fat separation imaging

Standard fat and water imaging

4.4 Fast inversion recovery fat/water suppression technology


Fat and water dual-suppression technology
Frequency selective fat/water saturation technology
SPAIR (Spectral Adiabatic Inversion Recovery) technology
Fat/Water excitation technology
Water/Fat separation technology

Advanced angiography

4.5 TOF (Time of flight) MR angiography


Auto pre-saturation technology
MTC (Magnetization Transfer Contrast) technology
TONE (Tilted Optimized Non-saturation Excitation) technology

www.anke.com 4
Shenzhen Anke High-tech Co., Ltd.

Background suppression imaging technology


PCMRA (Phase contrast MR angiography)
CEMRA (Contrast-enhanced MR angiography)
CEMRA automatic detection technology
ASL-MRA (Arterial Spin Labeling MR angiography)

Fast imaging technology

4.6 Rectangular FOV acquisition technology


Half-Fourier acquisition technology
Partial-echo acquisition technology
Dual-engine parallel acquisition technology
Key-hole imaging technology
K-space data share technology

Artifact suppression technology

4.7 Pre-saturation technology


Image normalize correction technology
Flow compensation technology
Oversampling technology
PROP (Periodically Rotated Overlapping Parallel) data filling technology
Gating technology
Breath-hold scanning technology

Advanced 3D post-processing

4.8 MPR (Multi Planar Reformation)


MIP (Maximum Intensity Projection)
MinIP (Minimum Intensity Projection)
CPR (Curved Planar Reformation)

www.anke.com 5
Shenzhen Anke High-tech Co., Ltd.

SuperMark 1.5T optional configuration

5. Optional application packages


No. Descriptions Note

5.1 DTI (Diffusion Tensor Imaging) Optional


*To obtain more accurate image information, the Diffusion tensor imaging (DTI) analysis
software (optional) and other accessories are required.

5.2 PWI (Perfusion Weighted Imaging) Optional


*To obtain more accurate image information, the MRI perfusion analysis software (optional)
and other accessories are required.

6. Optional coils
No. Descriptions Note

6.1 Additional Body coil – 6 Optional

6.2 Head coil – 8 Optional

6.3 Hand/Wrist coil – 8 Optional

6.4 Foot/Ankle coil – 8 Optional

6.5 Shoulder coil – 4 Optional

6.6 Breast coil – 8 Optional

www.anke.com 6
Shenzhen Anke High-tech Co., Ltd.
Address: Block B, LingYa Industrial Zone, Tangtou No.1 Road, Bao'an Twitter: ANKE (@ankeint)
District, Shenzhen, 518108, P.R. China
Facebook: ANKE (@ankemri)
Tel: +86-755-21622518 26688889
Fax: +86-755-26695307 26685908 Instagram: ANKE (@ankemarcom)
Email: [email protected] Linkedin: Shenzhen Anke High-tech Co., Ltd.
Website: www.anke.com
Specifications and appearance of the equipment may change without prior notice. ANKE reserves the right of final interpretation.