Data sheet 6GK5204-2BB10-2AA3

SCALANCE X204-2, managed IE switch, 4x 10/100 Mbit/s RJ45


ports, 2x 100 Mbit/s Multimode BFOC, LED diagnostics, error
signaling contact with set button, redundant power supply,
PROFINET IO device, network management; Redundancy Manager
integrated, incl. electron. manual on CD-ROM, C-plug optional

Product type designation SCALANCE X204-2

Transmission rate
Transfer rate 10 Mbit/s, 100 Mbit/s

Interfaces / for communication / integrated


Number of electrical connections
● for network components or terminal equipment 4
Number of 10/100 Mbit/s RJ45 ports / Integrated
● with securing collar 4
Number of 100 Mbit/s ST(BFOC) ports
● for multimode 2

Interfaces / others
Number of electrical connections
● for signaling contact 1
● for power supply 1
● for redundant voltage supply 1
Type of electrical connection
● for signaling contact 2-pole terminal block
● for power supply 4-pole terminal block

6GK5204-2BB10-2AA3 Subject to change without notice


Page 1/6 07/24/2018 © Copyright Siemens
design of the removable storage
● C-PLUG Yes

Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● at DC / Rated value 24 V
Operating current / of the signaling contacts
● at DC / maximum 0.1 A

Supply voltage, current consumption, power loss


Type of voltage / of the supply voltage DC
Supply voltage
● external 24 V
● external / minimum 18 V
● external / maximum 32 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage 0.6 A / 60 V
Consumed current / maximum 0.265 A
Power loss [W]
● at DC / at 24 V 6.36 W

Permitted ambient conditions


Ambient temperature
● during operation -40 ... +60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
Relative humidity
● at 25 °C / without condensation / during 95 %
operation / maximum
Protection class IP IP30

Design, dimensions and weight


Design compact
Width 60 mm
Height 125 mm
Depth 124 mm
Net weight 0.78 kg
Mounting type
● 35 mm DIN rail mounting Yes
● wall mounting Yes
● S7-300 rail mounting Yes
● S7-1500 rail mounting No

Product properties, functions, components / general


Cascading in the case of a redundant ring / at 100
reconfiguration time of <\~0.3\~s

6GK5204-2BB10-2AA3 Subject to change without notice


Page 2/6 07/24/2018 © Copyright Siemens
Cascading in cases of star topology any (depending only on signal propagation time)

Product functions / management, configuration


Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● Port mirroring Yes
● multiport mirroring No
● with IRT / PROFINET IO switch No
● PROFINET IO diagnosis Yes
● switch-managed Yes
Protocol / is supported
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● FTP Yes
● BOOTP No
● DCP Yes
● LLDP Yes
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location Yes
designation

Product functions / Diagnosis


Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes

Product functions / DHCP


Product function
● DHCP client Yes

Product functions / Redundancy


Product function

6GK5204-2BB10-2AA3 Subject to change without notice


Page 3/6 07/24/2018 © Copyright Siemens
● Ring redundancy Yes
● High Speed Redundancy Protocol (HRP) Yes
● high speed redundancy protocol (HRP) with Yes
redundancy manager
● high speed redundancy protocol (HRP) with No
standby redundancy
Protocol / is supported / Media Redundancy Protocol Yes
(MRP)
Product function
● media redundancy protocol (MRP) with Yes
redundancy manager
● Parallel Redundancy Protocol (PRP)/operation Yes
in the PRP-network
● Parallel Redundancy Protocol No
(PRP)/Redundant Network Access (RNA)
● Passive listening Yes

Product functions / Security


Protocol / is supported
● SSH Yes

Product functions / Time


Product function
● SICLOCK support Yes
Protocol / is supported
● NTP No
● SNTP Yes

Standards, specifications, approvals


Standard
● for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2,
GP. IIC, T4
● for hazardous zone EN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC
T4, KEMA 07 ATEX 0145 X
● for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 /
GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4
● for emitted interference EN 61000-6-4:2001 (Class A)
● for interference immunity EN 61000-6-4:2001

Standards, specifications, approvals / CE


Certificate of suitability / CE marking Yes

Standards, specifications, approvals / miscellaneous


Certificate of suitability EN 61000-6-4:2001
● C-Tick Yes

6GK5204-2BB10-2AA3 Subject to change without notice


Page 4/6 07/24/2018 © Copyright Siemens
● Railway application in accordance with EN No
50155
● Railway application in accordance with EN No
50124-1
● KC approval Yes

Standards, specifications, approvals / ship classification


Marine classification association
● American Bureau of Shipping Europe Ltd. Yes
(ABS)
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) Yes
● Germanische Lloyd (GL) Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (NK) Yes
● Polski Rejestr Statkow (PRS) Yes
● Royal Institution of Naval Architects (RINA) No

Standards, specifications, approvals / product conformity


MTBF 74.64 y

Accessories

Further Information / Internet Links


Internet-Link
● to website: Selector SIMATIC NET http://www.siemens.com/snst
SELECTION TOOL
● to website: Industrial communication http://www.siemens.com/simatic-net

● to website: Industry Mall https://mall.industry.siemens.com

● to website: Information and Download Center http://www.siemens.com/industry/infocenter

● to website: Image database http://automation.siemens.com/bilddb

● to website: CAx Download Manager http://www.siemens.com/cax

● to website: Industry Online Support https://support.industry.siemens.com

Security information

6GK5204-2BB10-2AA3 Subject to change without notice


Page 5/6 07/24/2018 © Copyright Siemens
Security information Siemens provides products and solutions with industrial security
functions that support the secure operation of plants, solutions,
machines, equipment and/or networks. They are important
components in a holistic industrial security concept. With this in
mind, Siemens’ products and solutions undergo continuous
development. Siemens recommends strongly that you regularly
check for product updates. For the secure operation of Siemens
products and solutions, it is necessary to take suitable preventive
action(e.g. cell protection concept) and integrate each component
into a holistic, state-of-the-art industrial security concept. Third-
party products that may be in use should also be considered. For
more information about industrial security, visit
http://www.siemens.com/industrialsecurity. To stay informed about
product updates as they occur, sign up for a product-specific
newsletter. For more information, visit
http://support.automation.siemens.com. (V3.4)

last modified: 07/24/2018

6GK5204-2BB10-2AA3 Subject to change without notice


Page 6/6 07/24/2018 © Copyright Siemens

You might also like