Technical Bulletin 22_2010 MFD


THIS BULLETIN REPLACE SB17!

MNS30 release + problem with RIB6 Network stability.

Description.

Improved MFD software MNS30 is released April 2010. At the same time also new firmware for RIB is is
available. To guarantee full advantage of new improved version following actions must be performed.

• Ghost and upgrade to MNS30. (Use MNS29 upgrade guide)


• Upgrade firmware in RIB6 to release 33. (Use RIB6 FW upgrade guide, with new firmware )
• Change Ethernet adapter drive setting in all computers according to instructions below. This will
be default settings in future release of OS image files.
• Enable watchdog by solder R2 in RIB6 according to below instructions, if this not already done
(SB16)

All firmware and instructions can be downloaded from Jet any time.

Ethernet Adapters Driver Adjustments

Open Device Manager and for each Realtek RTL8168C(P)/8111C(P) PCI-E Gigabit Ethernet NIC adapter
perform the following settings:

1. Go to page Advanced of the Realtek RTL8168C(P)/8111C(P) PCI-E Gigabit Ethernet NIC


Properties window and disable Wake-On-Lan After Shutdown:

Transas Marine International


Transas Marine International
Datavagen 37
Phone: +46 31 769 56 80
Fax: +46 31 694184
e-mail: [email protected]
web: www.transas.com

2. Go to page Power Management and uncheck Allow the computer to turn off this device to
save power checkbox.

Press OK button.

Note: Make above mentioned settings for both Ethernet adapters.

Transas Marine International


Transas Marine International
Datavagen 37
Phone: +46 31 769 56 80
Fax: +46 31 694184
e-mail: [email protected]
web: www.transas.com

Enable watchdog functionality

R2 close to reset button must be shortened using soldering iron.