Product Information For LOGO System Manual en-US en-US
Product Information For LOGO System Manual en-US en-US
Secure decommissioning 3
Technical data 4
LOGO!
Product Information for LOGO! LOGO! power modules
5
order number
System Manual in 06/2023 edition
Product Information
05/2024
A5E53808149-AA
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens Aktiengesellschaft. The remaining trademarks in
this publication may be trademarks whose use by third parties for their own purposes could violate the rights of
the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
1 Introduction ........................................................................................................................................... 4
2 Certification and approvals ................................................................................................................... 5
3 Secure decommissioning....................................................................................................................... 9
3.1 Securely removing data........................................................................................................ 9
3.2 Recycling and disposal ....................................................................................................... 10
4 Technical data...................................................................................................................................... 11
4.1 General technical data ....................................................................................................... 11
4.2 Technical data: LOGO! 230................................................................................................. 14
4.3 Technical data: LOGO! DM8 230R and LOGO! DM16 230R .................................................. 16
4.4 Technical data: LOGO! 24................................................................................................... 18
4.5 Technical data: LOGO! DM8 24 and LOGO! DM16 24 .......................................................... 20
4.6 Technical data: LOGO! 24RC............................................................................................... 22
4.7 Technical data: LOGO! DM8 24R and LOGO! DM16 24R ...................................................... 24
4.8 Technical data: LOGO! 12/24... LOGO! DM8 12/24R ............................................................ 26
4.9 Technical data: LOGO! TDE (Text Display with Ethernet interfaces)...................................... 28
5 LOGO! power modules order number ................................................................................................. 30
Index .................................................................................................................................................... 31
WARNING
Substitution of components can impair the suitability for Class I, Division 2 and
Zone 2.
Repair of units must be done by an authorized Siemens Service Center.
Note
You will find current approvals on the rating plate of the relevant module.
ID for Australia
Our products carrying the label shown at the side are compliant with AS/NZS
61000.6.4, AS/NZS 61000.6.3 standard.
ID for Korea
Our products (except the LOGO! CSM modules) carrying the label shown at the
side are compliant with Korean standards.
Disposal instructions, observe the local regulations and below Recycling and
Disposal.
LOGO! modules are therefore suitable for use in industrial and residential areas. Use in Class I,
Division 2, Group A, B, C and D locations or in non-hazardous locations is supported.
CCCEx approval
The following approvals according to the following standards are valid for a device with the
"CCC" marking.
• Standards:
– GB/T 3836.1-2021 (Explosive atmospheres - Part 1: Equipment - General requirements)
– GB/T 3836.3-2021 (Explosive atmospheres - Part 3: Equipment protection by increased
safety "e")
– GB/T 3836.8-2021 (Explosive atmospheres - Part 8: Equipment protection by type of
protection "n")
• Approvals:
– Ex ec nC IIC T4 Gc (module with relay outputs)
– Ex ec IIC T4 Gc
– -20 °C to +55 °C
NOTICE
Data misuse resulting from non-secure deletion of data
Incomplete or non-secure deletion of data from data memories can result in data misuse by
third parties.
For this reason, ensure secure deletion of data from all storage media used before disposing
of the product.
To delete all data from the data memories of LOGO! device, reset the device to factory
setting. The function deletes all information that was saved internally on the module. You
can take the following three methods to reset your LOGO! device to factory setting.
Note
The _reset.bm file can only be used to reset factory setting for LOGO! BM 8.3 and later
versions.
LOGO! Pure
71.5 x 90 x 58 mm
Dimensions (WxHxD)
Weight
Approx. 200 g
• Modules with relay output
Approx. 160 g
• Modules with transistor output On a 35 mm profile rail four module
Installation widths or wall mounting
LOGO! expansion modules DM16...
Dimensions (WxHxD) 71.5 x 90 x 58 mm
Weight
• Modules with relay output Approx. 225 g
Approx. 165 g
• Modules with transistor output
On a 35 mm profile rail four module
Installation widths or wall mounting
LOGO! expansion modules
DM8...
Dimensions (WxHxD) 35.5 x 90 x 58 mm
Weight
• Modules with relay output Approx. 130 g
• Modules with transistor output Approx. 95 g
On a 35 mm profile rail two module
Installation widths or wall mounting
LOGO! expansion modules
AM...
Dimensions (WxHxD) 35.5 x 90 x 58 mm
Weight Approx. 95 g
Installation On a 35 mm profile rail two module
widths or wall mounting
LOGO! TDE (Text Display with
Ethernet interfaces)
Dimensions (WxHxD) 128.2 x 86 x 38.7 mm
Weight Approx. 220 g
Installation Bracket mounting
1) The updating rate of LCD can be reduced at operating temperature less than 0°C.
Note
The maximum length for directly connecting two LOGO! Base Modules through CAT5e
shielded network cable is 100 meters.
Delay time at 1 to 0:
• 120 VAC • Typ. 45 ms • Typ. 45 ms
• 240 VAC • Typ. 70 ms • Typ. 70 ms
• 120 VDC • Typ. 60 ms • Typ. 60 ms
• 240 VDC • Typ. 75 ms • Typ. 75 ms
Line length (unshielded) max. 100 m max. 100 m
Digital outputs
Number 4 4
Output type Relay outputs Relay outputs
Electrical isolation Yes Yes
In groups of 1 1
Control of a digital input Yes Yes
Continuous current Ith Recommended range of Recommended range of
application ≥ 100 mA at application ≥ 100 mA at
12 VAC/VDC 12 VAC/VDC
Max. 10 A per relay Max. 10 A per relay
Relay rated voltage 240 VAC/VDC 240 VAC/VDC
Surge current Max. 30 A Max. 30 A
Incandescent lamp load (25000
switching cycles) at
• 230/240 VAC • 1000 W • 1000 W
• 115/120 VAC • 500 W • 500 W
Fluorescent tubes with ballast 10 x 58 W (at 230/240 VAC) 10 x 58 W (at 230/240 VAC)
(25000 switching cycles)
Fluorescent tubes, conventionally 1 x 58 W (at 230/240 VAC) 1 x 58 W (at 230/240 VAC)
compensated (25000 switching
cycles)
Fluorescent tubes, uncompensated 10 x 58 W (at 230/240 VAC) 10 x 58 W (at 230/240 VAC)
(25000 switching cycles)
Short circuit-proof cos 1 Power protection B16, 600 A Power protection B16, 600 A
Short circuit-proof cos 0.5 to 0.7 Power protection B16, 900 A Power protection B16, 900 A
Derating None; across the entire None; across the entire
temperature range temperature range
Parallel output circuits for power Not permitted Not permitted
increase
Notice: For fluorescent lamps with capacitors, you must consider the technical data of
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current,
appropriate contactor relays must switch the fluorescent lamps.
Notice: Output: B300, R300; 8A, 24 VDC, G.P.; 10A, 240 VAC, G.P.; 3A, 120 VAC, Tungsten.
The data was determined with the following devices:
• Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 uncompensated.
• Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 parallel compensated with 7 μF.
• Siemens fluorescent tubes 58 W VVG 5LZ 501 1-1N with ballast.
4.3 Technical data: LOGO! DM8 230R and LOGO! DM16 230R
Delay time at 1 to 0:
• 120 VAC • Typ. 45 ms • Typ. 45 ms
• 240 VAC • Typ. 70 ms • Typ. 70 ms
• 120 VDC • Typ. 60 ms • Typ. 60 ms
• 240 VDC • Typ. 75 ms • Typ. 75 ms
Line length (unshielded) Max. 100 m Max. 100 m
Digital outputs
Number 4 8
Output type Relay outputs Relay outputs
Electrical isolation Yes Yes
In groups of 1 1
Control of a digital input Yes Yes
Continuous current Ith Recommended range of Recommended range of
application ≥ 100 mA at application ≥ 100 mA at
12 VAC/VDC 12 VAC/VDC
Max. 5 A per relay Max. 5 A per relay
Relay rated voltage 240 VAC/VDC 240 VAC/VDC
Notice: For fluorescent lamps with capacitors, you must consider the technical data of
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current,
appropriate contactor relays must switch the fluorescent lamps.
The data was determined with the following devices:
Notice: Output: B300, R300; 5A, 24VDC, G,P.; 5A, 240 VAC, G.P.; 3A, 120VAC, Tungsten.
• Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 uncompensated.
• Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 parallel compensated with 7 μF.
• Siemens fluorescent tubes 58 W VVG 5LZ 501 1-1N with ballast.
LOGO! 24CE
LOGO! 24CEo
Power supply
Input voltage 24 VDC
Permissible range 20.4 VDC to 28.8 VDC
Reverse polarity protection Yes
LOGO! 24CE
LOGO! 24CEo
Permissible mains frequency --
Power consumption from 24 VDC 25 mA to 50 mA (no load on digital output)
1.2 A (with max. load on digital output)
Voltage failure buffering --
Power loss at 24 VDC 0.6 W to 1.2 W
Backup of the real-time clock at 25 °C Typ. 20 days
Accuracy of the real-time clock Typ. ± 2 s/day
Digital inputs
Number 8
Electrical isolation No
Number of high speed inputs 4 (I3, I4, I5, I6)
Input frequency
• Normal input • Max. 4 Hz
• High speed input • Max. 5 kHz
Digital input 24 VDC
Max. continuous permissible voltage 28.8 VDC
Input voltage L+
Signal 0 < 5 VDC
Signal 1 > 12 VDC
Input current at
Signal 0 < 0.9 mA (I3 to I6)
< 0.07 mA (I1, I2, I7, I8)
Signal 1 > 2.1 mA (I3 to I6)
> 0.18 mA (I1, I2, I7, I8)
Delay time at
0 to 1 • Typ. 1.5 ms
<1.0 ms (I3 to I6)
1 to 0 • Typ. 1.5 ms
<1.0 ms (I3 to I6)
Line length (unshielded) Max. 100 m
Analog inputs
Number 4 (I1=AI3, I2=AI4, I7=AI1, I8=AI2)
Range 0 VDC to 10 VDC
Input impedance 80 kΩ
Cycle time for analog value generation 300 ms
Line length (shielded and twisted) Max. 10 m
Error limit ± 1.5% at FS
Digital outputs
Number 4
Output type Transistor,
current-sourcing 1)
Electrical isolation No
In groups of --
Control of a digital input Yes
Output voltage ≤ Supply voltage
LOGO! 24CE
LOGO! 24CEo
Output current Max. 0.3 A per channel
Short circuit-proof and overload-proof Yes
Short circuit current limitation Approx. 1 A per channel
Derating None; across the entire temperature range
Short circuit-proof cos 1 --
Short circuit-proof cos 0.5 to 0.7 --
Parallel output circuit for power increase Not permitted
Protection of output relay (if desired) --
Line length (unshielded) Max. 100 m
Switching rate 2)
Mechanical --
Electrical 10 Hz
Ohmic load/lamp load 10 Hz
Inductive load 0.5 Hz
1) When you switch on LOGO! 24CE/24CEo, LOGO! DM8 24 or LOGO! DM16 24, the CPU sends signal
1 to the digital outputs for about 50 μs. Take this into account, especially when using devices that
react to short pulses.
2) The maximum switching rate is only dependent on the switching program's cycle time.
Notice: Output: 24 VDC, 0.3 A, RES./P.D.
Notice:
• Output of LOGO! DM8 24: 24 VDC, 0.3 A, RES./P.D.
• Output of LOGO! DM16 24: 24 VDC, 0.3 A, RES./P.D.; 3W, 24 VDC, Tungsten.
LOGO! 24RCE
LOGO! 24RCEo
Power supply
Input voltage 24 VAC/VDC
Permissible range 20.4 VAC to 26.4 VAC
20.4 VDC to 28.8 VDC
Reverse polarity protection --
Input frequency 50/60 Hz
Permissible mains frequency 47 Hz to 63 Hz
Power consumption
• 24 VAC • 60 mA to 185 mA
• 24 VDC • 25 mA to 100 mA
Voltage failure buffering Typ. 5 ms
Power loss
• 24 VAC • 1.4 W to 4.4 W
• 24 VDC • 0.6 W to 2.4 W
Backup of the real-time clock at 25 °C Typ. 20 days
Accuracy of the real-time clock Typ. ± 2 s/day
Digital inputs
Number 8, optional positive voltage or negative voltage
Electrical isolation No
Number of high speed inputs 0
Input frequency
• Normal input • Max. 4 Hz
• High speed input • --
Digital input 24 VAC/DC, 50/60 Hz
Max. continuous permissible voltage 26.4 VAC
28.8 VDC
Input voltage L
• Signal 0 • < 5 VAC/VDC
• Signal 1 • > 12 VAC/VDC
Input current at
• Signal 0 • < 1.2 mA
• Signal 1 • > 2.6 mA
LOGO! 24RCE
LOGO! 24RCEo
Delay time at
• 0 to 1 • Typ. 1.5 ms
• 1 to 0 • Typ. 15 ms
Line length (unshielded) Max. 100 m
Analog inputs
Number --
Range --
max. Input voltage --
Digital outputs
Number 4
Output type Relay outputs
Electrical isolation Yes
In groups of 1
Control of a digital input Yes
Continuous current Ith Recommended range of application ≥ 100 mA at
12 VAC/VDC
Max. 10 A per relay
Relay rated voltage 240 VAC/VDC
Surge current Max. 30 A
Incandescent lamp load (25000 switching 1000 W
cycles) at
Fluorescent tubes with ballast (25000 10 x 58 W
switching cycles)
Fluorescent tubes, conventionally 1 x 58 W
compensated (25000 switching cycles)
Fluorescent tubes, uncompensated (25000 10 x 58 W
switching cycles)
Derating None; across the entire temperature range
Short circuit-proof cos 1 Power protection B16, 600 A
Short circuit-proof cos 0.5 to 0.7 Power protection B16, 900 A
Parallel output circuits for power increase Not permitted
Protection of output relay Max. 16 A,
(if desired) characteristic B16
Line length (unshielded) Max. 100 m
Switching rate
Mechanical 10 Hz
Ohmic load/lamp load 2 Hz
Inductive load 0.5 Hz
Notice: For fluorescent lamps with capacitors, you must consider the technical data of
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current,
appropriate contactor relays must switch the fluorescent lamps.
Notice: Output: B300, R300; 8A, 24 VDC, G.P.; 10A, 24 VAC, G,P.; 3A, 120 VAC, Tungsten.
4.7 Technical data: LOGO! DM8 24R and LOGO! DM16 24R
Notice: For fluorescent lamps with capacitors, you must consider the technical data of
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current,
appropriate contactor relays must switch the fluorescent lamps.
Notice: Output: B300, R300; 5A, 24 VDC, G.P.; 5A, 240 VAC, G.P.; 3A, 120 VAC, Tungsten.
Notice: For fluorescent lamps with capacitors, you must consider the technical data of
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current,
appropriate contactor relays must switch the fluorescent lamps.
Notice:
• Output of LOGO! 12/24RCE/RCEo: B300, R300; 8A, 24 VDC, G.P.; 10A, 240 VAC, G.P.; 3A,
120 VAC, Tungsten.
• Output of LOGO! DM8 12/24R: B300, R300; 5A, 24 VDC, G.P.; 5A, 240 VAC, G.P.; 3A, 120
VAC, Tungsten.
The data was determined with the following devices:
• Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 uncompensated.
• Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 parallel compensated with 7 μF.
• Siemens fluorescent tubes 58 W VVG 5LZ 501 1-1N with ballast.
LOGO! TDE
Mechanical data
Keyboard Membrane keypad with 10 keys
Display FSTN-Graphic Display with 160 x 96 (columns x rows), LED
backlight (white/amber/red)
Power supply
Input voltage 24 VAC/VDC
12 VDC
Permissible range 20.4 VAC to 26.4 VAC
10.2 VDC to 28.8 VDC
Input frequency 50/60 Hz
Permissible mains frequency 47Hz to 63 Hz
Power consumption (Ethernet and
white backlight active)
• 12 VDC • Typ. 150 mA
• 24 VDC • Typ. 75 mA
• 24 VAC • Typ. 145 mA
LOGO! TDE
Degree of protection
IP20 for LOGO! TDE excluding front panel
IP65 for LOGO! TDE front panel
Enclosure type Type 4X/12 for LOGO! TDE front panel
Communication port
Ethernet performance Two Ethernet interfaces with 10/100 M full/half duplex data
transmission rate
Connection distance Max. 30 m
LCD Display and Backlight
Backlight lifetime 1) 20,000 hours
Display lifetime 2) 50,000 hours
Mounting
Mounting hole dimensions (WxH) (119 + 0.5 mm) x (78.5 + 0.5 mm)
Mounting conditions Mount the LOGO! TDE vertically on a flat surface of an IP 65
or Type 4x/12 enclosure.
1) The backlight lifetime is when the final brightness is 50% of the original brightness.
2) The display lifetime is calculated under ordinary operating and storage conditions: room
temperature (20 ± 8 °C), normal humidity below 65% relative humidity, and not in exposure to
direct sunlight.
A
Approval
CCCEx, 8
FM, 8
C
CCCEx, 8
Certification and approvals
CE label, 6
cFMus, 5
C-tick label, 6
cULus, 5
KCC label, 6
E