Products Solutions Services
Differential pressure
Deltabar PMD55
Differential pressure transmitter with metal
sensor for measurement of pressure
differences
F L E X Benefícios:
• Easy menu-guided commissioning via local display, 4 to 20mA with
HART, PROFIBUS PA, FOUNDATION Fieldbus
• Easy process adaptation to impulse line high-pressure/low-pressure
change via electric switch on the main electronics
• Compact design and modular concept for easy replacement of display
or electronics
• Process pressure up to SIL2, certified to IEC 61508 and IEC 61511
• Global usage thanks to the widest range of approvals for industries and
applications
Especificações resumidas
• Accuracy 0,1% "PLATINUM" 0,075%
Mais informações e preço atual: • Max. measurement error 0,1% "PLATINUM" 0,075%
www.br.endress.com/PMD55 • Process temperature -40 °C...85 °C (-40 °F...185 °F)
• Medium temperature range Temperature gradient from pressure
piping
• Pressure measuring range 10mbar...40bar (0.15...580psi)
Campo de aplicação: The Deltabar PMD55 differential pressure
transmitter with piezoresistive sensor and welded metallic membrane is
typically used in process or environmental applications for continuous
measurement of pressure differences in liquids, vapors and gases. Quick
Setup with adjustable measuring range allows simple commissioning,
reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.
Características e especificações
Deltabar M PMD55
Steam Measuring principle
Differential pressure
Product headline
Digital transmitter with metallic measuring
diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error
0,1%
"PLATINUM" 0,075%
Max. process pressure
10mbar...40bar
(0.15...580psi)
Medium temperature range
Temperature gradient from pressure piping
Display/Operation
Option
Outputs
4...20mA HART
Digital communication
HART
Hazardous area approvals
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety
SIL
2 Endress+Hauser
Deltabar M PMD55
Steam Material certificates
NACE MR0103
NACE MR0175
EN10204-3.1
Pressure Measuring principle
Differential pressure
Characteristic
Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Supply voltage
4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy
Standard 0.1%
Platinum 0.075%
Long term stability
0.05% of URL/ year
0.13% of URL/ 5 years
0.23% of URL/ 10 years
Process temperature
-40°C...+85°C
(-40°F...+185°F)
3 Endress+Hauser
Deltabar M PMD55
Pressure Ambient temperature
-40°C...+85°C
(-40°F...+185°F)
Measuring cell
10 mbar...40 bar
(0.15...580 psi)
Smallest calibratable span
10 mbar (0.15 psi)
Max. Turn down
20:1
Max. overpressure limit
on one side:
160 bar
(2300 psi)
Process connection
1/4-18 NPT
Material process membrane
316L, AlloyC,
Material gasket
Viton, PTFE, EPDM, NBR
Fill fluid
Silicone oil
Inert oil
Material housing
Die-cast aluminum
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
4 Endress+Hauser
Deltabar M PMD55
Pressure Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK
Ex
Safety approvals
SIL
Design approvals
NACE MR0175
EN10204-3.1
Successor
PMD55B
Gas Measuring principle
Differential pressure
Product headline
Digital transmitter with metallic measuring
diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error
0,1%
"PLATINUM" 0,075%
Max. process pressure
10mbar...40bar
(0.15...580psi)
Medium temperature range
Temperature gradient from pressure piping
Display/Operation
Option
5 Endress+Hauser
Deltabar M PMD55
Gas Outputs
4...20mA HART
Digital communication
HART
Hazardous area approvals
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety
SIL
Material certificates
NACE MR0103
NACE MR0175
EN10204-3.1
Continuous / Liquids Measuring principle
Differential pressure
Characteristic / Application
Digital transmitter with metallic measuring
diaphragms
Compact size
Modular transmitter
Long-term stability
Supply / Communication
4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
Accuracy
0,1%
"PLATINUM" 0,075%
6 Endress+Hauser
Deltabar M PMD55
Continuous / Liquids Long term stability
0,05% of URL/year
0,125% of URL/5 years
Ambient temperature
-40°C...85°C
(-40°F...185°F)
Process temperature
-40 °C...85 °C
(-40 °F...185 °F)
Process pressure / max. overpressure limit
160 bar
Pressure measuring range
10mbar...40bar
(0.15...580psi)
Main wetted parts
316L
Process connection
1/4-18 NPT
Communication
4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals
SIL
7 Endress+Hauser
Deltabar M PMD55
Continuous / Liquids Design approvals
EN 10204-3.1
NACE MR0175, MR0103
AD2000
Options
4-line digital display
Aluminium housing
Successor
PMD55B
Application limits
Measuring cell:
Metal welded
Liquids Measuring principle
Differential pressure
Product headline
Digital transmitter with metallic measuring
diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error
0,1%
"PLATINUM" 0,075%
Max. process pressure
10 mbar...40 bar
(0.15...580 psi)
Medium temperature range
Temperature gradient from pressure piping
8 Endress+Hauser
Deltabar M PMD55
Liquids Display/Operation
Option
Outputs
4...20mA HART
Digital communication
HART
Hazardous area approvals
ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety
SIL
Material certificates
NACE MR0103
NACE MR0175
EN10204-3.1
Mais informações www.br.endress.com/PMD55
Endress+Hauser Controle e addresses.endress.com
Automação Ltda.
[email protected]Brasil