Decarbonisation of
buildings made easy
VRV 5
Heat Pumps
RXYA-A
1 FLEXIBLE
Heat pump technology designed to suit any commercial building
› Extensive piping lengths and heights to meet any VRV application
› Quiet operation via 5 low sound steps, bringing sound pressure
down to 41 dB(A)
› Wide operation range down to -20°C in heating
and up to +46°C in cooling
› Continuous heating during defrost makes VRV 5
an ideal monovalent heating solution
2 SUSTAINABLE
Significantly reduces the CO2 footprint of your building
5
› Reduced indirect impact thanks to high Seasonal efficiency Potential
• ηs,c up to 298,3%, measured with most popular units global warming
• Reduces running costs compared to traditional systems impact low sound
› Reduced direct impact thanks to lower GWP R-32 refrigerant steps
• Up to 71% Global Warming Potential reduction
22,4 kW ~ 56,0 kW 25,0 KW ~ 63,0 kW
compared to R-410A
• Single-component refrigerant, easy to recover and reuse
• Reduced leak check requirement in line with F-gas
(only 1 inspection/ year up to 74kg of total charge) Find out all the details about
the new VRV 5 Heat Pumps
in our webinar
3 UNIQUE SHÎRUDO TECHNOLOGY
THIRD
Provides peace of mind PARTY
› Suitable for any room size: Shîrudo Technology allows easy installation APPROVED
of R-32 VRV in any room
› Maximum installation flexibility, thanks to factory-provided refrigerant control
measures Find out more
› No need for complex studies or field supplied equipment
about refrigerant safety standards
› 3rd party certification according to the product standard IEC60335-2-40
and Shîrudo Technology
4 SUPPORT
Wide network of experts with specialised advice
› Maximise BREAAM / LEED score
• Extra credit thanks to lower GWP of R-32
• Our accredited professionals assist to optimize the design
Our online support software with visual floorplan interface makes
design easy and ensures compliance with product standards
5 WIDEST R-32 PORTFOLIO
Match any application
› Widest range of specifically designed indoor units and air curtains:
11 unit models in 96 variations
› Plug & play ventilation solutions from 150 up to 140.000 m³/h
› Extensive range of intuitive controllers:
• Individual or centralized CONTROLLERS
• On-premises or in the Cloud
INDOOR VENTILATION
Specifications Module Single Units Multi combinations (continuous heating)
RYMA5A RXYA8A RXYA10A RXYA12A RXYA14A RXYA16A RXYA18A RXYA20A RXYA10A RXYA13A RXYA16A RXYA18A RXYA20A
Outdoor unit 1 RYMA5A
RYMA5A RXYA8A RXYA8A RXYA8A
System
Outdoor unit 2 RYMA5A
RXYA8A RXYA8A RXYA10A RXYA12A
Capacity range 5 8 10 12 14 16 18 20 10 13 16 18 20
Cooling capacity Prated,c 14,0 22,4 28,0 33,5 40,0 45,0 50,4 56,0 2836,4 44,8 50,4 55,9
Prated, h 22,4 28,0 33,5 40,0 45,0 50,4 56,0 2836,4 44,8 50,4 55,9
Heating capacity
Max. 25,0 31,5 37,5 45,0 50,0 56,5 63,0 32 41 50 46,5 62,5
1xFXFA50A2VEB 4xFXFA63A2VEB 3xFXFA50A2VEB 3xFXFA50A2VEB 4xFXFA63A2VEB 4xFXFA50A2VEB
Recommended combination Only for 4xFXFA50A2VEB 4xFXFA63A2VEB 6xFXFA50A2VEB + 5xFXFA63A2VEB + 2xFXFA80A2VEB + 5xFXFA63A2VEB 8xFXFA63A2VEB 4xFXFA63A2VEB + 3xFXFA63A2VEB + 2xFXFA80A2VEB + 4xFXFA63A2VEB 10xFXFA50A2VEB
SEER use in multi 7,26 7,06 7,04 7,67 6,99 6,87 6,52 7,55 7,42 7,12 7,18 7,16
combinations
SCOP 4,11 4,33 4,49 4,28 4,26 4,39 4,14 4,09 4,11 4,35 4,34 4,38
ηs,c 287,3% 279,3% 278,7% 302,2% 276,6% 271,6% 257,6% 299,1% 293,8% 281,9% 284,1% 283,2%
ηs,h 161,5% 170,2% 176,4% 168,3% 167,5% 172,5% 162,7% 160,6% 161,5% 170,9% 170,5% 172,2%
Dimensions HxWxD 1.685x930x765 1.685x1.240x765
Weight 214 297 320
Cooling 78,3 78,3 78,8 82,5 79,5 83,7 83,4 87,9 81,3 81,3 81,3 81,6 83,9
Sound power level
Heating 79,4 79,4 80,7 83,3 82,9 86,3 85,1 89,6
Sound pressure level Cooling 56,3 56,3 58,0 60,8 59,0 61,6 63,0 67,0 59,3 59,3 59,3 60,2 62,1
Operation range Cooling/Heating Min/Max °C ‘-5 ~ 46/ ’-20 ~ 16
Type/GWP R-32 / 675,0
Refrigerant
Charge tCO2eq/ kg 6,08/9,0 7,16/10,6
Liquid OD 9,5 9,5 9,5 12,7 12,7 12,7 12,7 12,7 9,5 12,7 12,7 12,7 12,7
Gas OD 19,1 19,1 19,1 22,2 22,2 28,6 28,6 28,6 19,1 22,2 28,6 28,6 28,6
Piping connections
Equilizing pipe 19,1 19,1 19,1 19,1 19,1
Total piping length System actual 1.000 500
Power supply Phase/Frequency/ Voltage 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) 20 20 25 32 32 40 40 50 40 40 40 50 50
Access all technical details here
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH
Lemböckgasse 59/1/1, 1230 Vienna, Austria · Tel.: + 43 (0) 1 253 21 11 · e-mail:
[email protected] · www.daikin-ce.com
Daikin Europe N.V participates in the Eurovent Certified Performance programme
Daikin products are distributed by: for Fan Coil Units and Variable Refrigerant Flow systems. Daikin Applied Europe
S.P.A participates in the Eurovent Certified Performance programme for Liquid
Chilling Packages, Hydronic Heat Pumps and Air Handling Units.
Check ongoing validity of certificate: www.eurovent-certification.com
The present publication is drawn up by way of information only and does not constitute an offer binding
upon Daikin Europe N.V. / Daikin Central Europe HandelsGmbH. Daikin Europe N.V. / Daikin Central Europe
HandelsGmbH have compiled the content of this publication to the best of their knowledge. No express or
implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content
and the products and services presented therein. Specifications are subject to change without prior notice. Daikin
Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage,
in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is
copyrighted by Daikin Europe N.V.
DACE VRV 5 Heat Pumps flyer 2023-2024 | November 2023
We reserve the right for printing errors and model changes