0% found this document useful (0 votes)
3K views1 page

TROPONIN T Test Report Format Example Sample Template Drlogy Lab Report

Uploaded by

atrozy abd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views1 page

TROPONIN T Test Report Format Example Sample Template Drlogy Lab Report

Uploaded by

atrozy abd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DRLOGY PATHOLOGY LAB 0123456789 | 0912345678

Accurate | Caring | Instant [email protected]

105 -108, SMART VISION COMPLEX, HEALTHCARE ROAD, OPPOSITE HEALTHCARE COMPLEX. MUMBAI - 689578

www.drlogy.com

Yash M. Patel Sample Collected At:


Age : 21 Years 125, Shivam Bungalow, S G Road,
Registered on: 02:31 PM 02 Dec, 2X
Sex : Male Mumbai
Collected on: 03:11 PM 02 Dec, 2X
PID : 555 Ref. By: Dr. Hiren Shah Reported on: 04:35 PM 02 Dec, 2X

TROPONIN- T, HIGH SENSITIVE


Investigation Result Reference Value Unit

TROPONIN- T, HIGH SENSITIVE, SERUM 11.00 < 14.00 pg/mL


ECLIA

Interpretation :

INITIAL RESULT IN pg/mL Remark

< 14.00 The upper reference limit (99th percentile) for high sensitive Troponin T(hsTn)

> 14.00 - < 53.00 Repeat sampling after 3 hours. 50% change in initial value is diagnostic of Myocardial infarction (MI)

> 53.00 - 100.00 Repeat sampling after 3 hours. 20% change in initial value is diagnostic of Myocardial infarction (MI)

> 100.00 WHO cut-off value diagnostic for MI

Note :
False positive results can be seen in the presence of Rheumatoid factor and heterophile antibodies.

Smart Pathology Laboratory


Due to the release kinetics of cardiac troponin T, an initial test result < 99th percentile within the initial hours of onset of
symptoms does not rule out Myocardial Infarction with certainty. If MI is still suspected, repeat the test 3 hours after initial
assessment.

Drlogy.com
Comments :
Cardiac Troponin is a cardiospecific, highly sensitive marker of myocardial damage , but is also expressed by diseased skeletal
muscle. Troponin T levels rise in serum about 3-4 hours after appearance of cardiac symptoms and remain elevated upto 14
days. It is an independent prognostic marker which can predict near, mid and long term outcome in patients with Acute Coronary
Syndrome (ACS). It is also a useful tool in guiding anti-thrombotic therapy.
Increased Levels :
Cardiac causes: Congestive Heart Failure, Cardiomyopathy, Myocarditis, Heart contusion, Interventional therapy like cardiac
surgery and drug induced cardiotoxicity
Non cardiac causes: Renal Failure, Lung embolism, Non-cardiac surgery , Rhabdomyolysis, Polymyositis, Stroke & Left
Ventricular dysfunction in Septic shock
Uses :
Exclusion diagnosis of Acute Myocardial Infarction
Monitoring Acute Coronary syndromes and estimating prognosis
Monitoring patients with non-ischemic causes of cardiac injury

Thanks for Reference ****End of Report****

Medical Lab Technician Dr. Payal Shah Dr. Vimal Shah


(DMLT, BMLT) (MD, Pathologist) (MD, Pathologist)

Generated on : 02 Dec, 202X 05:00 PM Page 1 of 1

Sample Collection 0123456789

You might also like