1 1478624-W2-A
Safety Information
WARNING ! This shower can deliver scalding temperatures. For
continued safe operation, follow all instructions, warnings and
cautions contained in this guide and on or inside the shower.
Periodic maintenance may be required to keep the product in
good working order.
The function of a thermostatic mixing valve is to deliver water
consistently at a safe temperature. In keeping with every other
mechanism, it cannot be considered as functionally infallible and
as such, cannot totally replace a supervisor’s vigilance where that
is necessary. Provided it is installed, commissioned, operated
and maintained within manufacturers recommendations, the
risk of failure, if not eliminated, is reduced to the minimum
achievable.
3 1478624-W2-A
Introduction
Thank you for choosing a Mira shower. To enjoy the full potential of your new shower, please
take time to read this guide thoroughly, and keep it handy for future reference. Products
manufactured by Kohler Mira Ltd are designed to be safe, provided that they are installed,
used and maintained in good working order, in accordance with our instructions and
recommendations.
Follow all warnings, cautions and instructions contained in this guide, and on, or inside
the shower. This guide is also available in digital format from our website or by contacting
customer services.
Type 2 Valves
This product has been certified as a Type 2 valve. It also complies with the Water Supply
(water fittings) regulations 1999. For further information on Type 2 Valves, refer to the TMV2
Requirements Manual (available to view or download on our website www.mirashowers.com).
The approved designation for this product is listed in the table below.
Guarantee
For domestic installations, Mira Showers guarantee the product against any defect in
materials or workmanship for a period of five years from the date of purchase (shower fittings
for one year).
For non-domestic installations, Mira Showers guarantee the product against any defect in
materials or workmanship for a period of one year from the date of purchase.
Failure to follow the instructions provided with the shower will invalidate the guarantee.
For Terms and Conditions refer to the 'Activating Your Free Guarantee and Customer
Service' pages.
Recommended Usage
Domestic Light Commercial
Heavy Commercial Healthcare
1478624-W2-A 4
Pack Contents
Important! Some parts may differ from the below depending on product purchased.
Mira PB
BI Evo
Installatio co
n and
User Gu
ide
al
o Du
Evoc
ple
o Tri For
Evoc ADVICE SPARES,
or REPA
please
These call us IRS
on 0800 free
instruct 001
ions mus (UK only)4040
Model t be left
Produ Name: with the
Date of ct Code:
Manufactur user
e: Affix Sticke
(Pleas r Here
e keep
produc these
t guaran details
tee. Your safe as
guaran you will
tee informa need them
tion is when
include registe
d in this ring your
guide.)
1478524-W
2-A
X1 q
X2 q
X1 q X1 q
X4 q X4 q X6 q
X1 q
X1 q
X2 q
X1 q
X1 q
X1 q
X1 q
X4 q X3 q
X1 q
X1 q X3 q X1 q
X3 q X1 q
X1 q
X1 q X2 q X1 q X1 q X1 q
5 1478624-W2-A
Important! Some parts may differ from the below depending on product purchased.
X1 q
X1 q
X1 q
X1 q
X1 q
X1 q
Silicone Sealant q
Additional Items Required (Not Supplied)
1478624-W2-A 6
Specifications
Pressures
Maximum Static Pressure 1000 kPa (10 bar)
Maximum Maintained Pressure 500 kPa (5 bar)
Minimum Maintained Pressure 100 kPa (1 bar)
(Gas Water Heater) (for optimum performance supplies should be
nominally equal)
Minimum Maintained Pressure 10 kPa (0.1 bar),
(Gravity System) (0.1 bar = 1 Metre head from cold tank base to shower
handset outlet)
Temperatures
Close temperature control 20°C - 50°C
Optimum Thermostatic Control 35°C to 45°C
Range (achieved with supplies of 15°C cold, 65°C hot and
nominally equal pressures)
Recommended Hot Supply 60°C to 65°C
Minimum Hot Water Supply Tem- 55°C (Note: The mixing valve can operate
perature at temperatures up to 85°C for short periods
without damage. However for safety reasons it
is recommended that the maximum hot water
temperature is limited to 65°C). Warm up feature
may not work if your hot inlet temp is below 55°C.
Minimum Recommended 12°C at desired flow rates
Differential between Hot Supply
and Outlet Temperature
Cold Water Range 1 - 25°C
Plumbing Connections
Hot: Left 15mm Push Fit
Cold: Right 15mm Push Fit
Outlet: Dual/Triple Outlet = RAC: 15mm Push Fit
Overhead and Bathfiller: 15mm Push Fit
• Important! This product uses 15mm Push fit connectors and is not suitable
for any other pipe sizes. We recommend the use of copper pipework.
• Warning! This product does not allow for reversed inlets and will deliver
dangerously unstable temperatures if fitted incorrectly.
Thermostatic Shut-down
• For safety and comfort the thermostat will shut off the mixing valve within
2 Seconds if either supply fails (achieved only if the blend temperature has
a minimum differential of 12°C from either supply temperature).
7 1478624-W2-A
Suitable Plumbing Installations
The Thermostatic Mixer can be installed with all systems with balanced pressures.
Mixed gravity and mains supplies are not recommended.
Installation
Warning! This product does not allow for reversed inlets and will deliver
unstable temperatures if fitted incorrectly.
General
1. Installation of the shower must be carried out in accordance with these
instructions by qualified, competent personnel.
2. The plumbing installation must comply with all national or local water regulations
and all relevant building regulations, or any particular regulation or practice
specified by the local water supply company.
3. Make sure all pressures and temperatures comply with the requirements of the
shower. See ‘Specifications’. For Type 2 Valves, refer to supply conditions
given in the TMV2 Requirements Manual (this is available to view or
download from our website www.mirashowers.com).
4. Full bore/non restrictive servicing valves must be fitted in a readily accessible
position adjacent to the shower to facilitate maintenance of the shower.
DO NOT use a valve with a loose washer plate (jumper) as this can lead to a
build up of static pressure.
5. The product contains built in check valves. DO NOT install inlet check valves
as this can lead to a build up of static pressure and potential product damage
and leaking.
6. DO NOT apply excessive force to plumbing connections; always provide
mechanical support when making plumbing connections. Any soldered joints
should be made before connecting the shower.
7. Pipework dead-legs should be kept to a minimum.
8. DO NOT install the shower unit in a position where access for maintenance is
restricted.
9. The shower must be fitted to a waterproof, flat and even wall surface.
Decorative and mosaic tiles are not recommended in the area where the shower
is to be installed, as they may cause problems with sealing around the valve
and also effect product operation.
10. The wall cavity must provide sufficient support for the shower unit. The 4 cavity
fixing screws (No. 10 x 2”) and wall plugs supplied are suitable for most solid
wall and stud partition installations. Use all 4 fixing points to secure the shower
unit, be sure to use fixings appropriate for the chosen wall structure. The front
concealing plate must be fitted to a waterproof, flat and even wall surface.
1478624-W2-A 8
11. Position the shower unit where the controls are at a convenient height for the
user. Position the showerhead so that the water sprays in line with the bath or
across the opening of a shower cubicle. The installation must not cause the
shower hose to be kinked during normal use.
12. A suitable waterproof shower tanking adhesive is required for the fabric wall
seal supplied. We recommend a liquid based plumbing type to be applied with
a paint brush, available from tile / builder merchants. A sufficient amount is
required for coating the fabric seal twice during the installation.
13. The water supplies to this product should be isolated if the product is not to be
used for a long period of time. If the product or pipework is at risk of freezing
during this period they should also be drained of water.
14. The position of the shower and shower fittings must provide a minimum air
gap of 25 mm between the showerhead and the spill over level of any bath,
shower tray or basin. There must be a minimum distance of 30 mm between
the showerhead and the spill over lever of any toilet, bidet or other appliance
with a Fluid Category 5 backflow risk.
Shower
Unit
Zone of
Backflow
Risk
25 mm
Minimum
30 mm
Minimum
25 mm Minimum
Note : There will be occasions when the hose retaining ring will not provide
a suitable solution for Fluid Category 3 installations. In these instances an
outlet double checkvalve must be fitted, this will increase the required
supply pressure typically by 10 kPa (0.1 bar). Double checkvalves fitted in
the inlet supply to the appliance cause a pressure build up, which affects
the maximum static inlet pressure for the appliance and must not be fitted.
For Fluid Category 5, double checkvalves are not suitable.
9 1478624-W2-A
Installation
Warning! Isolate the water supplies before installing the shower.
Overhead
Overhead Outlet
Outlet Pipe
Pipe
Bath Bath
Filler Filler
OR
Shower
Shower Fittings
Fittings Building In Building In
Box
Box
HOT COLD
HOT COLD
Water Inlets
Water Inlets
Determine the pipework route. All pipework to the product must be clipped and
supported to prevent movement and pipe noise due to any pulse pressures.
Position the outlet so that the shower hose will not obstruct the control handle and
the fixing screws will avoid the outlet pipe.
Warning! This product does not allow for reversed inlets and will deliver
dangerously unstable temperatures if fitted incorrectly.
1478624-W2-A 10
Copper
pipes into
push fit
connectors
Noggin
Mount
Noggin
OR
(x4)
Copper Clamp
pipes into
push fit
(x2)
Clamp connectors
Noggin
Rear Fixing Mounting Method Mount
OR
Clearance
Noggin
for outlet Noggin
Copper Mount
plug or third
pipes into
outlet
push fit
connectors
195-200mm
Copper
pipes into
push fit
connectors
36mm
Noggin Copper pipes
(x4) Mount into push fit
Clamp connectors
Note: For two outlet version, the top outlet will be blocked off. DO NOT
remove the outlet cap on the box.
Note: For wall depths greater than 90mm, please use the noggin mounts or
place a wood panel behind the product.
11 1478624-W2-A
Finished Finished Wall Thickness Wall Cutout
Wall
Surface
(e.g. tile and adhesive) Depth ‘X’
Rear 4mm 86 - 66mm
Mounting
6mm 84 - 64mm
8mm 82 - 62mm
10mm 80 - 60mm
12mm 78 - 58mm
14mm 76 - 56mm
16mm 74 - 55mm
Finished
Wall
Thickness
Depth (X)
Minimum
1477011-6-A Finished
Finished Wall Wall Surface
Finished Between Max and Min
Wall
Min
Surface
Max
Maximum
Finished
Noggin Wall Surface
Mount
Finished
Wall
Thickness
Depth (X)
Create a suitable cavity for the Building In Box and the pipework.
Cut away the plasterboard and/or brick work to the required depth.
Important! This depth ‘X’ will depend on the finished wall thickness e.g. tiles
or facia board. Refer to the table for this measurement.
For stud partitions depth ‘X’ refers to the distance from the rear mounting e.g. timber
noggin, to the front of the wall (before tiling).
Secure the Building in Box into the cavity. Use a 6 mm diameter drill to suit the wall
plugs supplied for solid walls. DO NOT use wall plugs when securing to noggin or
wooden panel.
1478624-W2-A 12
Important! DO NOT remove the cap for Dual Outlet product.
Cap
Blanking
Plugs
Blanking Blanking
Plug Collet Plugs
Evoco Dual Evoco Triple
Push and hold the collet before removing the blanking plugs.
36mm
Locking
HOT COLD
Clips
Insert locking Important! Cut the pipe using a pipe cutter only to ensure the seals
clip here
are not damaged when the pipe is inserted. Remove all burrs.
Note: Grease sachets are supplied and a small amount should be applied to
the end of the pipe to aid insertion.
Push fit the inlet and outlet pipework into the Building In Box. Hold the box securely
while fixing the pipework. Insert the locking clips (supplied) to secure the pipes in place.
Warning! Mark each piece of pipework at 36mm. The push-fit connections
contain seals (x2). Make sure you push the pipes in the full 36mm as indicated
to completely engage (you should feel the pipes push past both seals when
you do this). There is a risk of leaking if pipe work not fully pushed into the
connector.
13 1478624-W2-A
Overhead
Outlet
Pipe
Bath
Filler
Shower
Fittings
Building In
Box
HOT COLD
Water Inlets
Evoco Triple
Overhead
Outlet
Pipe
Bath
Filler
OR
Shower
Fittings
Building In
Box
HOT COLD
Water Inlets
Evoco Dual
Fit the outlet pipework ready for connection to either a right angle connector for a
handset, bath (adjustable fitting), or a shower arm for a fixed spray head (rigid fitting).
Ensure adequate pipe is extruding from the wall for each of the outlets.
Refer to the shroud button icons for the outlet configuration. If incorrectly installed
please refer to button replacement section.
1478624-W2-A 14
Flushing the Pipework
A flushing cartridge is prefitted into the Building in Box
to aid in flushing any dirt or debris from the pipework.
Push fit stop end caps are required to test the Building In
Box’s inlet and outlet joints for leaks.
Cover
a b a b Push Fit
Stop End
c d c d
e f e f
g h g h
15 1478624-W2-A
Built up surface / Plasterboard
(non waterproof)
1477011-6-A
Finished Wall
Between Max and Min
Min
Max
Finished Wall
Thickness
Depth
Cut a hole in plasterboard using a 152mm hole cutter and build a surface up to the
sides of the Building in Box ready for waterproof finishing.
75mm
75mm
Apply a liberal coat of waterproof adhesive (not supplied) around the product.
Use a suitable waterproof shower tanking adhesive. We recommend a liquid based
plumbing type to be applied with a paint brush, available from tile / builder merchants.
A sufficient amount is required for coating this area twice during the installation.
1478624-W2-A 16
Radius
Fabric Wall
Seal
Fit the fabric wall seal and press flat around the edges, creating a radius around the
sides of the Building in Box.
3-
23
mm
2mm Max.
Taking care to prevent damage to the wall finish, trim the Building in Box back to
within 2 mm from the finished wall surface.
Silicone
Sealant
Apply silicone sealant to fill the gap around the Building in Box.
1478624-W2-A 18
Flushing
Cartridge
Cover
Remove the cover but do not throw Make sure both water supplies are isolated
away as it can still be used to before removing the flushing cartridge.
stop debris during finishing of the Remove the five screws and remove the
installation. flushing cartridge and discard.
Yellow Valve
Cover
Seal
Mixing
Important! Check cleanliness of seals.
Valve
Adjustment
Screw
Seal
Mixing Valve
Concealing
Plate
Ribs
1478624-W2-A 20
Yellow Setting
Piece
Adjustment
Screw
2 Click
The adjustment screws have to be set to ensure when the concealing plate is fitted
the on/off buttons work correctly to turn the shower on and off.
Push the setting piece over the adjustment screw until it clips into position.
Gently unscrew the adjustment screw until it just touches the setting piece and take
care to not press down when unscrewing, when in position there will be a clicking
noise (2 clicks) to indicate the adjustment screw is in its correct position.
Depress the clips to remove setting piece and repeat for all adjustment screws
21 1478624-W2-A
Adjustment
Screw
White Fixing
Piece White Fixing Piece
Place the fixing piece over the adjustment screw (as shown). Push and clip the
fixing piece to lock adjustment screw in position.
30
mm
Control Coupler
Note: Fix the control coupler if the front of the mixing valve is less than
30mm from tile.
Note: Make sure that the spline is oriented in line as shown above.
1478624-W2-A 22
Push shroud on and
Concealing clip in position.
Plate
Grommet
Place the shroud over the valve ensuring the logo is in the correct orientation as
shown.
Push the shroud onto the fixing plate, and clip into place.
Pull the shroud gently to ensure its clipped into place.
23 1478624-W2-A
Override Button
Note: Position of "TOP" area on the valve may not be facing upwards and
MUST to be manually rotated into the position shown.
Note: This completes the initial installation of the mixing valve. Complete
the shower fittings installation then go to commissioning section.
c d
Fix with appropriate fixings at convenient height for all users. Position so
that water sprays down the centre of the bath, or away from the opening
of a shower cubicle. Water should spray away from the mixing valve when
e f showerhead is held on the slide bar.
the
g h
1300mm Minimum to
achieve a comfortable
shower height for all users
90°
25 1478624-W2-A
a b
Disassemble the components by turning
c d Backplate
grubscrew clockwise.
Collet
e f Seal Retainer
g
Retaining h
Elbow
Plate
Grubscrew
Seal
Cover
a b
Mark the positions for the fixing holes for
c d the RAC back plate.
e f
g h
a b
c d
The screws and wall plugs supplied are
e f suitable for most solid wall installations.
Alternative fixing screws for panel structures
g h are not supplied.
Use both fixing points to secure the right
angle connector, be sure to use fixings
appropriate for the chosen wall structure.
Drill the fixing holes, fit the wall plugs and
secure the backplate to the wall with two
8.0mm
fixing screws.
1478624-W2-A 26
c d
a
e f
g h
a b Seal Seal
Retainer
c d
e f Secure the fixing parts onto the pipework.
Fixing Hole
Position
520mm to top
hole position
27 1478624-W2-A
g h
a i
b j Drill the fixing hole for the top support and
fit the wall plug and screw top support into
position.
c k
d l Note: DO NOT tighten screw fully
as some slight adjustment may be
e m
f n
7.0mm
required when fitting slide bar.
g h
Fit the cover over the elbow and lock
i j into place by turning the grub screw
a b anticlockwise.
k l
c d
m n
e f
g h
i j
Fit all the components onto the slide bar
k l and fit the slide bar assembly in position,
making sure that it locates correctly.
m n
Slide Bar Support
Clamp Bracket
1478624-W2-A 28
i j
Carefully remove the slide bar assembly
k l and tighten the screw on the back of the
slide bar support to secure in position.
m n Slide Bar Refit the fit the slide bar assembly in
Support
position.
Slide Bar
Support
c d
e f
g h
i j Rear View of Top
Slide Bar Support
k l
Secure the assembly in position with
m n the screws. The top securing screw
tightens Clockwise, the bottom one
Anti-clockwise. Do not overtighten!
29 1478624-W2-A
c d
k l
e f Fit the cap to the top of the slide bar.
m n
g h
i j
k l
m n
o p
Handset
Hose Washer
Shower Hose
Flow Regulator
Hose Washer
Warning! Slide bar must
not be used as a grab rail.
Shower Hose
c d Minimum Distance to
Note: Cut the pipe to the correct
length and remove any burrs.
Ceiling 35mm
e f
g h
25 ± 2mm
a b
c d Mark the positions of the backplate fixing
holes.
e f Caution! Be aware of hidden pipes
or cables.
g h
Backplate
31 1478624-W2-A
a b c d
c d e f
e f g h
g h
Retaining Ring
6.0mm
Retaining Nut
c d
backplate. Yellow Nut
Overhead
e f Note: Apply grease
around the pipe.
Arm
g h
Shroud
Fit the overhead body over the pipe Note: Make sure that the pipe is pushed
and secure with the fixing screws until it hits the internal stop feature.
provided.
Secure by tightening the yellow nut on the
overhead body. Hand tighten only.
1478624-W2-A 32
e f
g h Push the shroud over the bracket body until
it clicks into place.
a b
Shroud
c d
e f
g h
DO NOT fit the deluge head until after the
i j pipework has been fully flushed through.
Screw the deluge head onto the shower arm
k l by hand.
m n
Flow
Regulator
Deluge
Head
Backplate
6mm Recess
Copper
Pipe Retaining Ring
Retaining Nut
Screw
a. Loosely screw the backplate to the wallplate with the two backplate screws
provided.
b. Place the wallplate and backplate assembly over the copper pipe.
c. Mark the position of the wallplate and its fixing holes on the wall.
d. Remove the screws and backplate from the wallplate.
e. Drill the two backplate fixing holes, if necessary make a recess approximately
6mm deep to accept the wallplate. Plug the two fixing holes.
f. Place the wallplate over the copper pipe and fix to the wall with the two wallplate
screws.
g. Temporarily fit the two backplate screws to the wallplate. This will prevent the
holes from becoming blocked with plaster and grout.
h. Finish the surface of the wall as required ensuring the pipework is protruding by
25mm ± 2mm.
i. Remove the two backplate screws.
j. Place the backplate against the finished wall surface and use the two backplate
screws supplied to fix the backplate to the wallplate.
k. Follow steps (e) - (i) from previous section to complete the shower arm installation.
1478624-W2-A 34
Installation of Bath Filler
Note: When the bath filler waste is extended,
there may be a need to rotate the bodies
to allow alignment to the both mating
surface.
Refer below steps:
• Loosen the jubilee clip at the overflow
end.
• Rotate the overflow body.
Jubilee Clip
g hOverflow
Hose
Fixing
Plate
Screws
Protective Cover
Filler (DO NOT install)
Head
Note: Ensure the screws are not cross threaded and are tightened evenly.
Hand tighten only. DO NOT use a power driver to tighten the screws.
Important! When installing the Mixer Valve to be used as a bath filler ensure
the flow rate of the bath overflow fitted exceeds the flow rate output from
the Mixer Valve.
35 1478624-W2-A
a b
Water Stopper
c d Installation Tool
e f Strainer
g h Gasket
Drain Assembly
Gasket
Waste
Body
Turn anti-clockwise to remove the water stopper then remove the installation tool,
then reassemble the water stopper to the waste body without the installation tool.
a b
c d
e f
g h
1478624-W2-A 36
a b
c d mm
in
30m
e f
g h
Locking Clip
Note: Make sure that the pipe is pushed in fully (min 30mm)
until it hits the internal stop feature.
Important! Cut the pipe using a pipe cutter only to ensure the seals are not
damaged when the pipe is inserted. Remove all burrs.
a b
Push fit the water supply pipe to the bath filler using copper pipework (15mm diameter).
Insert thedlocking clips (supplied) to secure the pipe in place.
c
e f
g h
Turn on the water supply and check for leaks from the waste and the bath filler
connections.
37 1478624-W2-A
Commissioning
Before turning water back ON, ensure the product is in the OFF position. Turn
product fully anticlockwise, then turn the water back ON.
Maximum Temperature Setting
Before using the shower, the maximum temperature must be checked to make sure
that it is at a safe level. It has been preset to a safe showering temperature under
ideal conditions at the factory, appropriate for most systems. However, site conditions
and personal preference may make it necessary to reset this temperature.
Note: Make sure that the hot water temperature is at least 55°C and that
there is sufficient supply.
Caution! Before making any adjustments to the shower, operate the temp
control from max hot to cold and make sure hot and cold water flows
correctly from the shower outlet. After making any adjustments repeat
this process.
1. Turn the temperature handle anticlockwise until it stops and test that the
temperature of the water from the shower outlet is hot enough.
2. If not, depress the override button and carefully rotate the handle further. If the
water temperature is still not hot enough complete the following procedure.
3. Rotate the temperature handle back to the override position.
4. Remove the handle by using the blade on the setting piece, place in between
the bottom of the handle and the shroud and twist to unclip the handle.
Setting
Piece
Handle
1478624-W2-A 38
5. Remove the maximum temperature peg from the top of the valve by using a
screwdriver. Refit the handle.
Note: Maximum temperature
achievable is 49°C.
Temperature
Peg
Operation
User can individually choose the handshower, overhead or bath filler by pressing
respective button on the product. If all buttons pressed, user can use handshower,
overhead and bath simultaneously.
Important! Read the 'Safety Information' before using your shower.
Note: With some water systems there may be insufficient water flow to
operate all outlet's together.
Note: When diverting from showerhead to overhead or bath filler a small
amount of cold water may initially flow.
On/Off and Temperature Control Start the shower by pressing one of the
outlet buttons.
White LED Only for Lit Variants, After pushing one
Ring of the outlet buttons, the LED ring will
pulse. This is to highlight that the water is
warming up, when the LED ring changes
to a continuous light the shower is ready
to use.
Warm up feature may not work if your hot
inlet temp is below 55°C.
39 1478624-W2-A
The temperature is controlled by rotating
Temperature the temperature handle.
Override
Operate the shower and make sure it
delivers cold water initially and then further
Temperature rotate to increase temperature, for safety
Selector reasons, the temperature is limited by an
Handle
override stop.
Press the override button on the
temperature handle and continue to rotate
Decrease
Temperature
the handle to obtain a higher temperature.
Pressing the selected outlet button again
Increase Temperature will turn the product off.
User Maintenance
Warning! Please observe the following to reduce the risk of injury or product
damage:
• DO NOT allow children to clean or perform any user maintenance to the shower
unit without supervision.
• If the shower is not to be used for a long period, the water supply to the shower
unit should be isolated. If the shower unit or pipework is at risk of freezing during
this period, a qualified, competent person should drain them of water.
Button Replacement
1478624-W2-A 40
Filter Cleaning
Remove the handle by using the blade on the setting piece, place in between the
bottom of the handle and shroud and twist to unclip the handle.
Shroud
Spline
Note: Make sure that the spline is oriented in line as shown above.
Insert a flat screwdriver into slot available at bottom of the shower unit and push the
spring clip. Carefully lift the shroud and remove from the shower unit.
41 1478624-W2-A
Spline
Carefully pull out the spline along with the lug from mixing valve.
1478624-W2-A 42
Carefully pull out the cartridge from the mixing valve.
Seals
43 1478624-W2-A
Cleaning
Always read the IMPORTANT SAFETY INFORMATION for your shower.
Cleaning the showerhead
Many household and commercial cleaners, including hand and surface cleaning
wipes contain abrasive and chemical substances that can damage plastics, plating
and printing and should not be used. These finishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
De-scaling the Showerhead and inspecting the hose
Warning! Failure to keep the showerhead nozzles clear or inspect the hose
for blockage or internal/external collapse can restrict the flow rate from the
shower. This may cause damage to the shower or result in the temperature
delivered to the user rising to unsafe levels with a risk of scalding. You
MUST ALWAYS check the temperature before using the shower.
1478624-W2-A 44
Fault Diagnosis
If you require a Mira trained service engineer or agent, refer to ‘Customer Service’.
Spare Parts
A list of spares for these products are available from the Mira Website, visit website
www.mirashowers.com.
45 1478624-W2-A
Disposal and Recycling
When this appliance has reached the end of its serviceable life it should be disposed
of in a safe manner, in accordance with current local authority recycling or waste
disposal policy. For more information about recycling, please contact your local
council office.
1478624-W2-A 46
Activate your Free* Guarantee
Thank you for choosing Mira. By registering your product, Keeping your information
this will act as your proof of purchase and enable us to We keep your Personal Information for six years after you
provide the best possible after sales service. terminate your policy so that we can deal with any claims. Your
goods information we keep for a bit longer, normally 10 years
REGISTER NOW visit the Mira website (the average life of an appliance) for health and safety. We also
keep your information to send you marketing that you might be
guarantee page
interested in, unless we receive a request from you to opt-out of
www.mirashowers.co.uk/support/guarantee.htm marketing.
Rights to your information
(You will need the Model Name, Product Code and Date of By writing to the Data Protection Officer using the contact details
Manufacture. This information can be found on the front page of provided below, you have the right to ask us:
this guide) • For a copy of the Personal Information we hold about you
• For a copy of the Personal Information you provided to
* If you do not activate your guarantee proof of purchase us to be sent to you or a third party in a commonly used,
will be required. machine readable format
• To update or correct your Personal Information to keep it
Mira has appointed Domestic & General Insurance PLC to provide
accurate
product registration services and protection plans to accompany
• To delete your Personal Information from our records if it is
its products.
no longer needed for the original purpose; and
• To restrict the processing of your Personal Information in
What we do with your information
certain circumstances
At Domestic & General we want to reassure you that we use
your information both responsibly and securely to provide And you may also:
you with the best possible service. Below we explain what we • Object to us processing your Personal Information, in
do with your information and your rights to your information. which case we will either agree to stop processing or
If you would like any further details you can get in touch explain why we’re unable to, and
with us using the contact details below or visit our website • Where we rely on your consent, withdraw that consent at
(www.domesticandgeneral.com). any time
Using your information Please note that the above rights are not absolute and certain
Domestic & General Insurance PLC (“we”) is the “data controller” exemptions apply to them. You can also make a complaint to
of your information. We process two sets of information about you, the Information Commissioner (www.ico.org.ukl) if you feel your
“Personal Information” (your name, address, contact and payment Personal Information has been mishandled.
details) and the “Goods Information” you provide to register your
appliance or device (your name, address, contact and goods
details). We’ll use your information: Marketing
(i) As necessary to fulfil our contract with you (including to recover We, along with other members of our Group and Kohler Mira
any amounts owing); (ii) for our legitimate interests in: undertaking Limited may use your information to tell you about any offers,
marketing (about our products and services and those of our third products or services which may be of interest to you. We may
party partners) by post, telephone, email and/or other electronic contact you by post, telephone, email and/or other electronic
messaging services; market research; customer surveys; printing messaging services.
services; checking and verifying your identity and contact details; To change your marketing preference, let us know by emailing
recording your conversations for training, quality and compliance [email protected] or by writing
purposes; and for analytics and profiling for marketing purposes; to us using the contact details provided below. For Kohler Mira
and (iii) where required to do so by law. We may also ask for your Limited marketing you’ll need to contact them directly using
consent to some uses of your information. their contact details that you’ll normally find in their privacy
notice.
Sharing your information
From time to time your Personal Information and Goods Information
may also be shared with other members of the Domestic & General Contact Details
Group of Companies (Domestic & General Insurance or Services If you need to contact us about your information or your
and other future members of the Group whose details we will notify information rights, or to see a copy of our Model Clauses, please
to you (“Group”), where applicable with Kohler Mira Limited which wrote to Freepost Plus RTKS-CLRA-GRYE, Data Protection
is the subject of your protection policy and with companies acting Officer, Domestic & General, Leicester House,
on our behalf or providing services to us (e.g. the companies we 17 Leicester Street, Bedworth CV12 8JP or
use to carry out repairs, IT & mailing services, storage of paper [email protected] and we’ll be happy to
records and telecommunications). Kohler Mira Limited will process help you.
your Personal Information for their legitimate business interests
(including marketing and analytics) in accordance with their privacy
policy.
47 1478624-W2-A
Customer Service
Guarantee What to do if something goes wrong
Your product has the benefit of our manufacturer’s If your product is not working correctly please refer
guarantee which starts from the date of purchase. to this manual for fault diagnosis and to check that
This guarantee only applies in the United Kingdom it is installed and commissioned in accordance with
and Republic of Ireland. our instructions. If this does not resolve the issue,
our Customer Services team are here to help get you
Activating Your Guarantee back up and running. To help us solve your problem
Registering your guarantee is quick and simple. To quickly, please have your product name, power rating
ensure your product is covered, please register online . (if applicable) and date of purchase to hand.