PWD Puducherry UG Cable BOQ
PWD Puducherry UG Cable BOQ
32 Supply and fixing LED street light fitting on existing/ New street
light arms having 140Watts -160W and above (system wattage), IP
65/66, white colour with necessary over voltage, under voltage and
surge protection with three years onsite warranty for replacement/ each 12.00 12
rectification. (Make:-Philips/Havells /LEDGEO/ Crompton/ Bajaj /
Eveready)The rate is inclusive of all taxes.
33 Supply and erection of 9.00mt. Octagonal GI pole with ring
arrangement at top suitable for fixing 4/5 nos. of light fittings.Pole
height - 9.00mt. with pole dimensions 150mm, dia at bottom and
100mm, dia at top. Base plate dimension - 300mm x 300mm x
16mm, including earth work excavation, providing foundation and
pedestal concrete with RCC 1:2:4 (1 Cement, 2 coarse sand, 4
graded stone aggregate 20mm, nominal size). The size of foundation
900 x 900 x 1500mm .and pedestal above ground level of size 450 x each 3.00 3
450 x 450mm fixing with required bolts and nuts providing
40mm.dia medium class GI pipe 2.00mts. length for cable raising
etc. complete as directed by the Engineer-in-charge. The rate is
including all materials, labours, transportation, fixing charges and
all other applicable taxes.
Gland
end termination with brass compression gland - 4 X 16 sq.mm (28
per set 42
8 mm).
end termination with brass compression gland 31/2 X50 sq.mm (32
per set 200
9 mm)
end termination with brass compression gland 31/2 X95 sq.mm (45
per set 2
10 mm)
end termination with brass compression gland a- 31/2 X300 sq.mm (70
per set 24
11 mm)
end termination with brass compression gland a 31/2 X400 sq.mm (82
per set 4
12 mm)
Lugs
13 3Cx185 Sq MM Indoor Kit Nos 4
14 3Cx95 Sq MM Indoor Kit Nos 4
Earthing Material
Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia.
each 50
24 G.I. pipe medium class of length 3.05m
25 G.I. flat (25 x 6mm) metre 250
26 8x25mm Bolt & Nut No 120
27 12x75mm Bolt & Nut No 50
28 4.00 mm dia copper wire metre 680
29 charcoal(50 Kgs) and salt (25 Kgs) No 42
60cm dia precast ring with 60cm depth allround,covered with R.C.C. No 42
30 precast slab
32
48 / 50 W LED Street Light Fitting with three years onsite warranty for
each 70 Phillips,Havells,
33 replacement /rectificaton.
CABLE SCHEDULE TE
SL NO DESCRIPTION FROM TO
1 3CX95 SQ.MM.AL.AR.CABLE RMU TR-1 7 2 214 3.5 2 2 230.5
RMU TR-2 7 188 80 3.5 2 2 282.5
513 4
6 WAY S/S
2 3.5CX400 SQ.MM.AL.AR.CABLE TR-1 PILAR PANEL 9 22 58 3.5 2 5 99.5
6 WAY S/S
TR-2 PILAR PANEL 9 11 30 21 3.5 2 4 80.5
180 4
6 WAY S/S 8 WAY S/S
3 3.5CX300 SQ.MM.AL.AR.CABLE PILAR PANEL PILAR PANEL-1 7 75 7 2 2 93
8 WAY S/S
PILAR PANEL-2 7 35 7 2 2 53
8 WAY S/S
PILAR PANEL-3 7 20 7 2 2 38
8 WAY S/S
PILAR PANEL-4 7 82 7 2 2 100
8 WAY S/S
PILAR PANEL-5 7 28 18 38 7 2 2 102
Common Load
Panel-6 7 28 18 38 64 7 2 2 166
8 WAY S/S
PILAR PANEL-10 7 50 21 48 7 2 2 137
8 WAY S/S
PILAR PANEL-11 7 50 21 48 33 7 2 2 170
Common Load
Panel-6 7 28 18 38 64 7 2 2 166
1079 24
8 WAY S/S
6 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-1 Home-1 7 26 33 11 7 84
Home-2 7 26 33 13 11 7 97
Home-3 7 26 11 13 7 64
Home-4 7 14 11 7 39
Home-5 7 10 14 7 38
Home-6 7 10 5 7 29
Home-7 7 10 5 7 29
Home-8 7 10 5 7 29
0
8 WAY S/S
7 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-2 Home-9 7 24 10 7 48
Home-10 7 12 10 7 36
Home-11 7 12 10 7 36
Home-12 7 15 10 7 39
Home-13 7 15 10 7 39
Home-14 7 12 10 7 36
Home-15 7 12 10 7 36
Home-16 7 24 10 7 48
0
8 WAY S/S
8 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-3 Home-17 7 24 10 7 48
Home-18 7 12 10 7 36
Home-19 7 12 10 7 36
Home-20 7 15 10 7 39
Home-21 7 15 10 7 39
Home-22 7 12 10 7 36
Home-23 7 12 10 7 36
Home-24 7 24 10 7 48
0
8 WAY S/S
9 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-4 Home-25 7 24 10 7 48
Home-26 7 12 10 7 36
Home-27 7 12 10 7 36
Home-28 7 15 10 7 39
Home-29 7 15 10 7 39
Home-30 7 12 10 7 36
Home-31 7 12 10 7 36
Home-32 7 24 10 7 48
0
8 WAY S/S
10 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-5 Home-33 7 24 10 7 48
Home-34 7 12 10 7 36
Home-35 7 12 10 7 36
Home-36 7 15 10 7 39
Home-37 7 24 10 7 48
Home-38 7 12 10 7 36
Home-39 7 12 10 7 36
Home-40 7 15 10 7 39
8 WAY S/S
11 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-6 Home-41 7 15 10 7 39
Home-42 7 12 10 7 36
Home-43 7 12 10 7 36
Home-44 7 24 10 7 48
Home-45 7 24 10 7 48
Home-46 7 12 10 7 36
Home-47 7 12 10 7 36
Home-48 7 15 10 7 39
8 WAY S/S
12 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-7 Home-49 7 15 10 7 39
Home-50 7 12 10 7 36
Home-51 7 12 10 7 36
Home-52 7 24 10 7 48
Home-53 7 24 10 7 48
Home-54 7 12 10 7 36
Home-55 7 12 10 7 36
Home-56 7 15 10 7 39
8 WAY S/S
13 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-8 Home-57 7 15 10 7 39
Home-58 7 12 10 7 36
Home-59 7 12 10 7 36
Home-60 7 24 10 7 48
Home-61 7 24 10 7 48
Home-62 7 12 10 7 36
Home-63 7 12 10 7 36
Home-64 7 15 10 7 39
0
8 WAY S/S
14 3.5CX50 SQ.MM.AL.AR.CABLE PILAR PANEL-9 Home-65 7 15 10 7 39
Home-66 7 12 10 7 36
Home-67 7 12 10 7 36
Home-68 7 24 10 7 48
Home-69 7 24 10 7 48
Home-70 7 12 10 7 36
Home-71 7 12 10 7 36
Home-72 7 15 10 7 39
0
8 WAY S/S
PILAR PANEL-
15 3.5CX50 SQ.MM.AL.AR.CABLE 10 Home-73 7 15 10 7 39
Home-74 7 12 10 7 36
Home-75 7 12 10 7 36
Home-76 7 24 10 7 48
Home-77 7 24 10 7 48
Home-78 7 12 10 7 36
Home-79 7 12 10 7 36
Home-80 7 15 10 7 39
0
8 WAY S/S
PILAR PANEL-
16 3.5CX50 SQ.MM.AL.AR.CABLE 11 Home-81 7 15 10 7 39
Home-82 7 12 10 7 36
Home-83 7 12 10 7 36
Home-84 7 24 10 7 48
Home-85 7 24 10 7 48
Home-86 7 12 10 7 36
Common Load
17 Panel-12
Common Load
18 4CX50 SQ.MM.AL.AR.CABLE Panel-11
SL-P 7 42 7 56
SL-P 7 42 42 7 98
SL-P 7 42 64 7 120
SL-P 7 42 120 7 176
Bore well 7 42 64 7 120
Sump 7 42 120 7 176
Sinking Well 7 42 120 7 176
Hight Mass
4CX50 SQ.MM.AL.AR.CABLE SL-P Pole-1 7 150 7 164
Hight Mass
Pole-2 7 30 7 44
Hight Mass
Pole-3 7 150 7 164
5031 200