SOLENOIDS AND SOLUTIONS
QUALITY SINCE 1912
Polarised Single-Acting 10
DC Solenoid Product group
M GB P 010
z To VDE 0580 and ISO 9001
z Miniature design
z For push and pull operation
z Bi-stable operation allows two stable, de-energised
positions of armature
z Increased holding force using integrated permanent
magnets
z Impulse operation for low power consumption and
minimal temperature rise
z Short closing time
z Coil to insulation rating B
z Protection rating
z DIN VDE 0470 / EN 60 529 - IP 20
z Mounting via tapped hole and location pin in frame
Fig. 1: Type M GB P 010 E20 D01
z Special designs on request
z Application:
Textile and packaging machines, office equipment,
control technology, general locking applications
Magnet Schultz Limited • 3-4 Capital Park • Old Woking • Surrey • GU22 9LD • UK
Phone: ++44 (0) 1483 794700 • Fax: ++44 (0) 1483 757298 • [email protected] • www.magnetschultz.co.uk
[email protected]
SOLENOIDS AND SOLUTIONS Phone: ++44 (0) 1483 794700
QUALITY SINCE 1912
Technical data Function
Solenoid type M GB P 010 E20 D01 is a bi-stable design. In
M GB P 010 E20 D01 extended position, in which the stroke has to be limited
externally, the armature is held by a return spring.
Operating mode S3 5 % By electrical impulse energisation of the coil, the armature moves
Rated voltage (V) 24 into its seated position. In this retracted position the armature is
held by the holding force of a permanent magnet.
Retracting voltage * (V) ca. 0.5 ... 0.7 UN
Reverse polarity returns the armature. Size of the counter-impulse
Stroke s (mm) 2.5 depends on counter-load and impulse duration.
Work rating AN (Ncm) 0.075
The technical data were taken from sample solenoids and are
Rated Power P20 (W) 6.7 estimated values. In production, deviations may occur owing to
Closing time t1 * (ms) 8 natural dispersion.
Armature weight mA (kg) 0.0025
Solenoid weight mM (kg) 0.0066
* Function of counter-load and impulse duration. FM - Permanent magnets
and coil energised
(without spring return)
1) at UN, R20
Rated voltage 24 VDC, on request the coil winding can be
adjusted to a rated voltage of 60 VDC maximum. 2) at 0.63 UN, R20
(= minimale Anzugsspannung UAnzmin)
The magnetic-force values mentioned in the diagram refer
to 90 % of the rated voltage, (UN = 24 VDC, for other voltages
the magnetic force may deviate) and in cold condition.
Owing to natural dispersion, the magnetic-force values may
deviate by ± 10 % from the values indicated in the tables.
Attracting and retracting times are a function of counterload and FM - Permanent magnets
impulse duration. The attracting time values mentioned in the
table were taken at rated voltage, R20, with return spring.
Hot condition is based on:
a) rated voltage 24 VDC Spring force
b) operating mode S3 5%
c) reference temperature 35° C
d) mounting on heat-insulating base
Fig. 2: Magnetic force vs stroke M GB P 010 E20 D01
Please make sure that the described devices are suitable
for your application. Please find further details and definitions
in our Technical Explanation or, respectively, in VDE 0580.
Note on the technical harmonisation Note on the EMC (electromagnetic compatibility) guideline
guidelines within the EU 89/336 EWG
Electromagnetic solenoids of this product range are subject to Electromagnetic solenoids are not affected by this guideline
the low-voltage guideline 73 / 23 EWG. because neither do they cause electromagnetic disturbances
nor can they be disturbed through electromagnetic
To guarantee the targets of this regulation, products are
disturbances. Therefore, the adherence to the EMC guideline
manufactured and inspected to the valid edition of DIN
has to be guaranteed by the user through appropriate circuitry
VDE 0580. This also equals a declaration of conformity by
wiring. Examples for protection circuits can be taken from the
the manufacturer.
corresponding technical documents.
Data may be changed without notice – dimensions not guaranteed. Subject to our Standard Conditions
2
[email protected]
Phone: ++44 (0) 1483 794700 SOLENOIDS AND SOLUTIONS
QUALITY SINCE 1912
Dimension
4 x crimped
MSM, type
Armature is shown in
the seated condition
Circuit diagram
closing red (+) black (-)
opening red (-) black (+)
red black
Fig. 3: Type M GB P 010 E20 D01
The solenoid shown is not a ready-to-use device in the sense
of DIN VDE 0580. The general requirements and protective
measures to be taken by the user, are included in DIN VDE
0580. The use of the shown device in safety relevant
applications needs always the written agreement of MSM.
Data may be changed without notice – dimensions not guaranteed. Subject to our Standard Conditions
3
[email protected]
SOLENOIDS AND SOLUTIONS Phone: ++44 (0) 1483 794700
QUALITY SINCE 1912
Type code
M GB P 010 E 20 D01
Equipment group
Basic construction
Modifications
Size
Arrangement
Basic protection
Design number
Order Example
Type M GB P 010 E20 D01
Voltage 24 V DC
Operating mode S3 5 %
Specials
Please do not hesitate to ask us for application-
oriented problem solutions. In order to find a reliable
solution quickly we need complete details about your
application conditions. The details should be specified
as precisely as possible in accordance with the rele-
vant - technical explanations.
If necessary, please request the support of our corres-
ponding technical office.
Data may be changed without notice – dimensions not guaranteed. Subject to our Standard Conditions
4 Printed in Germany 112006/00 Ss