SR NO.
SERVICE CODE SERVICE DESCRIPTION DETAIL DESCRIPTION UOM Assam North East
TRENCHING AND DUCTING THROUGH HDD INCLUDING FIXING OF DUCT
COUPLERS & END CAPS - LAYING OF 1 NOS 40 MM HDPE DUCT BY HDD
CHRG TRENC, HDD,1NOS 40MM METHOD BY CONTRACTOR OWNED MACHINES. CONTRACTOR SHALL
1 304403175 M 280 320
DUCT,VENDOR MC SUPPLY ALL CONSUMABLES AND LABOUR INCLUDING ACCESSORY
WORK VIZ. MAKING OF TERMINATION PITS, DISPOSAL OF EXCESS
EARTH MATERIAL ETC. FOR COMPLETING THE WORK
TRENCHING AND DUCTING THROUGH HDD INCLUDING FIXING OF DUCT
COUPLERS & END CAPS - LAYING OF 2 NOS 40 MM HDPE DUCT BY HDD
CHRG TRENC, HDD,2NOS 40MM METHOD BY CONTRACTOR OWNED MACHINES. CONTRACTOR SHALL
2 304403114 M 310 350
DUCT,VENDOR MC SUPPLY ALL CONSUMABLES AND LABOUR INCLUDING ACCESSORY
WORK VIZ. MAKING OF TERMINATION PITS, DISPOSAL OF EXCESS
EARTH MATERIAL ETC. FOR COMPLETING THE WORK
Laying of 40 mm HDPE duct in INSTALLATION OF 1 NO., 40MM OD HDPE DUCTS BY OPEN TRENCHING
3 304403115 M 350 410
trench-MAN METHOD IN ALL TYPES OF SOIL.
Laying of 40 mm HDPE duct in INSTALLATION OF 1 NO., 40MM OD HDPE DUCTS BY OPEN TRENCHING
4 304403116 M 410 430
trench VIB METHOD IN ALL TYPES OF SOIL.
i) Round base plate of 1000 mm diameter and 75 mm thickness in single
lid
(ii) Full round RCC Chamber with diameter of 1000 mm (Outer), 900 mm
(Inner) and
height of 800 mm and thickness of 50 mm
(iii) Round top cover will be in single lid with diameter of 1000 mm and
thickness of
Supply & Installation of Ring 75mm having two handle word ‘VI OFC’ engraved on it.
5 304403117 EA 9000 11000
Chambers
Concrete mixture will be 1:2:4, 1 part cement to 2 parts sand and 4 parts
of
aggregates. After, fixing the pre-cast RCC joint chamber, the joint
chamber to be
filled with clean sand before closing. Partner should ensure backfilling of
excavated
pit and clean the surface.
Supply & Installation of Brick Installation of Manhole Chamber (1.0mX1.0mx1.0m) inside using first class
6 304403118 bricks in 1:4 mortar. RCC top cover of manhole with iron frame (1:2:4 cement EA 15000 17000
Chambers
concrete, 12mm tor iron bars) size : 1.3mX0.6mX0.1m, 1.3mX0.6mX0.1m
SPLICING,JOINTING &
7 304403141 CHARGES FOR SPLICING,JOINTING & TERMINATION OF 48F FIBRE. EA 100 100
TERMINATION-48F
SPLICING,JOINTING &
8 304403142 CHARGES FOR SPLICING,JOINTING & TERMINATION OF 96F FIBRE. EA 90 100
TERMINATION-96F
SPLICING,JOINTING &
9 304403143 CHARGES FOR SPLICING,JOINTING & TERMINATION OF 12F FIBRE. EA 120 120
TERMINATION-12F
SPLICING,JOINTING &
10 304403144 CHARGES FOR SPLICING,JOINTING & TERMINATION OF 6F FIBRE. EA 120 120
TERMINATION-6F
SPLICING,JOINTING &
11 304403145 CHARGES FOR SPLICING,JOINTING & TERMINATION OF 24F FIBRE. EA 120 120
TERMINATION-24F
SPLICING AND TERMINATION OF
12 304101912 SPLICING AND TERMINATION OF FMS-48 F EA 120 120
FMS
Cleaning by removing of water / dirt / slush / foreign material from the
13 304403148 CHRG:CLEANING OF MANHOLE EA 2500 3000
Manhole with tools tackles all complete as directed by EIC.
14 304403149 Sand Filling in 1 Mtr X 1 Mtr Chamber EA 500 700
Sand Filling in 850 MM X 850 MM
15 304403150
Chamber EA 500 700
LAYING OF 48 MM OD COMPOSITE DUCT, COMPRISING OF 40 MM HDPE
DUCT # 1 NO WITH THE HELP OF MOLING / AUGERING BY CREATING
MOLING/AUGERING-1NO 40MM
16 304403151 DUCT REQUISITE SIZE OF THE HOLE AND PULING THE REQUIRED NOS OF M 450 500
DUCTS THRU THE HOLE. THE RATES ARE INCLUSIVE OF THE LOCAL
LIASION CHARGES.
LAYING OF 2 NOS 40 MM HDPE DUCT WITH THE HELP OF MOLING /
LAY & MOLING/AUGER OF 40 MM AUGERING BY CREATING REQUISITE SIZE OF THE HOLE AND PULING THE
17 304403152 M 510 610
DUCT W/2 NOS REQUIRED NOS OF DUCTS THRU THE HOLE. THE RATES ARE INCLUSIVE
OF THE LOCAL LIASION CHARGES.
C2 – Vodafone Idea Internal
Providing & Laying 50mm dia B Class GI pipe (Tata/ Jindal /Asian or
approved equivalent) including cutting, threading, jointing, laying, cost of
all required fittings like bends, couplers, tees, reducers, stop ends,
clamps, necessary chasing in brick and making good, removal of debris,
18 304304760 P&L 50 MM GI PIPE M 750 850
application of non-corrosive bitumen paint on GI pipes, testing
and commissioning etc. complete as per drawings,
specifications and as
directed by EIC.
Providing & Laying 150mm dia B Class GI pipe (Tata/ Jindal /Asian or
approved equivalent) including cutting, threading, jointing, laying, cost of
all required fittings like bends, couplers, tees, reducers, stop ends,
clamps, necessary chasing in brick and making good, removal of debris,
19 304403154 P&L 150 MM GI PIPE M 900 950
application of non-corrosive bitumen paint on GI pipes, testing
and commissioning etc. complete as per drawings,
specifications and as
directed by EIC.
PULLING/BLOWING OF OFC- 96 F INCLUDING ALL MATERIALS, LABOUR,
20 304403155 BLOWING / PULLING-96 F M 35 35
TOOLS, TACKLES, ETC..
PULLING/BLOWING OF OFC- 48 F INCLUDING ALL MATERIALS, LABOUR,
21 304403156 BLOWING / PULLING-48 F M 26 26
TOOLS, TACKLES, ETC..
PULLING/BLOWING OF OFC-12F INCLUDING ALL MATERIALS, LABOUR,
22 304336448 BLOWING / PULLING-12 F M 22 22
TOOLS, TACKLES, ETC..
PULLING/BLOWING OF OFC-6F INCLUDING ALL MATERIALS, LABOUR,
23 304403158 BLOWING / PULLING-6 F M 22 22
TOOLS, TACKLES, ETC..
DE-BLOWING OF 96F FIBRE CABLE FROM HDPE 40MM DUCT THROUGH
BLOWING MACHINE/ MANUALLY, INCLUDING DEPOSITING THE CUT
24 304403159 DE-BLOWING OF 96F FIBRE CABLE M 40 40
LENGTH BACK TO WAREHOUSE AND INCLUDING ALL TOOLS AND
TACKLES NECESSARY AS PER INSTRUCTION EIC
DE-BLOWING OF 48F FIBRE CABLE FROM HDPE 40MM DUCT THROUGH
BLOWING MACHINE/ MANUALLY, INCLUDING DEPOSITING THE CUT
25 304403160 DE-BLOWING OF 48F FIBRE CABLE M 35 35
LENGTH BACK TO WAREHOUSE AND INCLUDING ALL TOOLS AND
TACKLES NECESSARY AS PER INSTRUCTION EIC
26 304101817 CHRGS:DUCT INTEGRITY TEST CHARGES FOR DUCT INTEGRITY TEST(DIT). M 10 15
SUPPLY AND LAYING OF WARNING TAPE IN EXCAVATED TRENCHES AS
27 304403162 S&L OF WARNING TAPE M 20 25
DIRECTED BY EIC .ITEM INCLUDES TRANSPORTATION
DISPOSAL OF WASTE MATERIALS Collection & disposal of various kinds of unwanted materials / debris at
28 304403163 EA 2500 3000
DEBRIS ETC. specified location inside terminal with tractor ,trolley etc.per trip.
DISMANTALING OF AERIAL CABLES- DISMANTALING OF AERIAL CABLES-96F DE-INSTALLATION OF OPTICAL
29 304403164 M 30 35
96F FIBER CABLE & OTHER ACCESSORIES USED IN AERIAL WORKS.
DISMANTALING OF AERIAL CABLES- DISMANTALING OF AERIAL CABLES-48F DE-INSTALLATION OF OPTICAL
30 304403165 M 20 25
48F FIBER CABLE & OTHER ACCESSORIES USED IN AERIAL WORKS.
DISMANTLING OF AERIAL CABLES-12F DE-INSTALLATION OF OPTICAL
31 304403166 DISMANTLING OF AERIAL CABLES-12F M 20 25
FIBER CABLE & OTHER ACCESSORIES USED IN AERIAL WORKS.
DISMANTLING OF AERIAL CABLES-6F DE-INSTALLATION OF OPTICAL
32 304403167 DISMANTLING OF AERIAL CABLES-6F M 22 22
FIBER CABLE & OTHER ACCESSORIES USED IN AERIAL WORKS.
INSTALLATION OF THE AERIAL CABLE (96 F ADSS ) ALONG WITH THE
33 304403168 INSTALLATION 96 F ADSS ACCESSORIES. RATE INCLUDES SURVEY COST AND LOCAL LIASIONING M 50 60
CHARGES.
INSTALLATION OF THE AERIAL CABLE (48 F ADSS ) ALONG WITH THE
34 304403169 INSTALLATION 48 F ADSS ACCESSORIES. RATE INCLUDES SURVEY COST AND LOCAL LIASIONING M 45 35
CHARGES.
INSTALLATION OF THE AERIAL CABLE (12 F ADSS ) ALONG WITH THE
35 304403170 INSTALLATION12F ADSS ACCESSORIES. RATE INCLUDES SURVEY COST AND LOCAL LIASIONING M 35 40
CHARGES.
INSTALLATION OF THE AERIAL CABLE (6 F ADSS ) ALONG WITH THE
36 304403171 INSTALLATION 6F ADSS ACCESSORIES. RATE INCLUDES SURVEY COST AND LOCAL LIASIONING M 30 35
CHARGES.
37 304403172 CHRG R&M MANHOLE NECK RAISING CHRG R&M MANHOLE NECK RAISING EA 15000 17000
CHARGES FOR REINSTATEMENT OF THE TRENCHES / PITS INCLUDING ALL
MATERIALS , LABOUR, TOOLS TACKES ETC..BY PCC -1:2:4 GRAVEL SIZE -
CHRG;REINST,TRENCH,PCC-
38 304403173 1:2:4,GRAVEL 20MM 20 MM & CURING FOR 7 DAYS. THIS ITEM SHALL BE OPERATED WHERE M3 500 600
THE TRENCH / PIT IS TO BE REINSTATED AS PER THE ROW GUIDELINE OF
WITHIN BUILDING COMPLEXES AS PER RWA GUIDELINE
C2 – Vodafone Idea Internal
CHARGES FOR RESTORATION OF THE EXCAVATED SURFACES USING THE
HOT BITUMEN INCLUDING PROPER COMPACTION ETC. ALL COMPLETE
RSTRTN EXCVTD SURFACES-W/ HOT
39 304403174 BITUMEN INCLUDING ALL MATERIALS TOOLS TACKLES ET., AS PER THE M 600 700
SPECIFICATION AND DIRECTION OF ENGINEER IN CHARGES WIDTH 300
MM
40 304110299 OFC work by JCB OFC work by JCB EA 1500 1800
C2 – Vodafone Idea Internal