Standard specifications
Rating
Three-phase 400V power supply
Model FR-D740- K(-C)∗6 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Model FR-D740- -NA 012 022 036 050 080 120 160
Model FR-D740- -EC 012 022 036 050 080 120 160
Model FR-D740- K-CHT 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Applicable motor capacity (kW)∗1 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Rated capacity (kVA)∗2 1.2 2.0 3.0 4.6 7.2 9.1 13.0
Output
Rated current (A) 1.2 2.2 3.6 5.0 8.0 12.0 16.0
Overload current rating∗3 150% 60s, 200% 0.5s (inverse-time characteristics)
Voltage∗4 Three-phase 380 to 480V
Rated input voltage/frequency Three-phase 380 to 480V 50Hz/60Hz
Power supply
Permissible AC voltage fluctuation 325 to 528V 50Hz/60Hz
Permissible frequency fluctuation ±5%
Power supply capacity (kVA)∗5 1.5 2.5 4.5 5.5 9.5 12 17
Protective structure (JEM1030) Enclosed type (IP20). IP40 for totally enclosed structure series.
Cooling system Self-cooling Forced air cooling
Approximate mass (kg) 1.2 1.2 1.3 1.4 1.5 3.1 3.1
∗1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
∗2 The rated output capacity indicated assumes that the output voltage is 440V.
∗3 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for
the inverter and motor to return to or below the temperatures under 100% load.
∗4 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the pulse voltage value of the inverter output side voltage remains unchanged at about 2 that of the power supply.
∗5 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
∗6 Totally enclosed structure series ends with -C.
Single-phase 200V power supply
Model FR-D720S- K 0.1 0.2 0.4 0.75 1.5 2.2
Model FR-D720S- -NA 008 014 025 042 070 100
Model FR-D720S- -EC 008 014 025 042 070 100
Model FR-D720S- K-CHT 0.1 0.2 0.4 0.75 1.5 2.2
Applicable motor capacity (kW)∗1 0.1 0.2 0.4 0.75 1.5 2.2
Rated capacity (kVA)∗2 0.3 0.5 1.0 1.6 2.8 3.8
Output
Rated current (A) 0.8 1.4 2.5 4.2 7.0 10.0
Overload current rating∗3 150% 60s, 200% 0.5s (inverse-time characteristics)
Voltage∗4 Three-phase 200 to 240V
Rated input voltage/frequency Single-phase 200 to 240V 50Hz/60Hz
Power supply
Permissible AC voltage fluctuation 170 to 264V 50Hz/60Hz
Permissible frequency fluctuation ±5%
Power supply capacity (kVA)∗5 0.5 0.9 1.5 2.3 4.0 5.2
Protective structure (JEM1030) Enclosed type (IP20).
Cooling system Self-cooling Forced air cooling
Approximate mass (kg) 0.5 0.6 0.9 1.1 1.5 1.9
∗1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
∗2 The rated output capacity indicated assumes that the output voltage is 230V.
∗3 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for
the inverter and motor to return to or below the temperatures under 100% load.
∗4 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the pulse voltage value of the inverter output side voltage remains unchanged at about 2 that of the power supply.
∗5 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
5
Outline Dimension Drawings
FR-D720S-0.1K to 0.75K
5
1-φ5 hole
128
118
Rating
plate
5 4
D1
5
56
D
68
Inverter Type D D1
FR-D720S-0.1K, 0.2K 80.5 10
FR-D720S-0.4K 142.5 42
FR-D720S-0.75K 162.5 62
(Unit: mm)
FR-D740-0.4K to 3.7K
FR-D720S-1.5K
5
FAN *
2-φ5 hole
118
128
Rating
plate
5 5
5
96 D1
108 D
∗ FR-D740-0.4K, 0.75K are not provided with the cooling fan.
Inverter Type D D1
FR-D740-0.4K, 0.75K 129.5 54
FR-D740-1.5K 135.5
FR-D740-2.2K 155.5
60
FR-D740-3.7K 165.5
FR-D720S-1.5K 155.5
(Unit: mm)
7
Terminal Connection Diagram
Source logic
*1. DC reactor (FR-HEL)
Main circuit terminal When connecting a DC reactor, remove the
Control circuit terminal jumper across P1-P/+
Single-phase power input Brake unit *6 A brake transistor is not built-in to the
(Option) FR-D720S-0.1K and 0.2K.
MCCB MC
Single-phase R/L1 *1 R *7 Brake resistor (FR-ABR, MRS)
AC power Earth Install a thermal relay to prevent an
S/L2 *7
supply (Ground) overheat and burnout of the brake resistor.
Jumper PR N/- (The brake resistor can not be connected
to the FR-D720S-0.1K and 0.2K.)
MCCB MC P1 P/+ *6
Motor
Three-phase R/L1 U
AC power S/L2 V
IM
supply T/L3 W
Earth Main circuit
(Ground) Earth (Ground)
Control circuit
Control input signals (No voltage input allowed) C Relay output
Forward STF
Terminal functions vary rotation start Terminal functions vary
B by Pr. 192 A,B,C terminal
with the input terminal Reverse STR Relay output
assignment (Pr. 178 to rotation start (Fault output) function selection
A
Pr. 182) RH
High
speed
RM Open collector output
Multi-speed selection Middle
SOURCE
speed Terminal functions vary by
RUN
SINK
*2 When using terminals PC- Low RL
SD as a 24VDC power Running Pr. 190 RUN terminal function
speed selection
supply, take care not to SD
short across terminals Contact input common
PC-SD.
PC *2 SE Open collector output common
24VDC power supply Sink/source common
Contact input common
(Common for external power supply transistor)
Frequency setting signals (Analog)
10(+5V) Calibration resistor
3 Indicator
*3 Terminal input specifications Frequency (Frequency meter, etc.)
can be changed by analog
+ -
setting 2 0 to 5VDC *3
input specifications 2 Moving-coil type
switchover (Pr. 73). potentiometer (0 to 10VDC) FM
Terminal 10 and terminal 2 1/2W1kΩ 1mA full-scale
*8
are used as PTC input *5 SD
terminal (Pr. 561). 1 5(Analog common)
*4 Terminal input *8 It is not necessary when
specifications can be Terminal 4 PU calibrating the indicator
changed by analog input input (+) 4 4 to 20mADC from the operation panel.
connector
specifications switchover (Current (-) 0 to 5VDC
0 to 10VDC *4
(Pr. 267). Set the
voltage/current input input)
switch in the "V" position
to select voltage input (0 V I
to 5V/0 to10V) and "I"
(initial value) to select Voltage/current
current input (4 to 20mA). input switch *4
*5 It is recommended to use 2W1kΩ
when the frequency setting signal
is changed frequently.
To prevent a malfunction caused by noise, separate the signal cables more than 10cm from the power cables.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean. When drilling mounting holes
in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
To ensure safety, for single-phase power input specification model, connect the power input to the inverter via a
magnetic contactor and earth leakage circuit breaker or moulded case circuit breaker, and use the magnetic
contactor to switch power on-off.
The output of the single-phase power input specification is three-phase 200V.
11