Arteor TM
multistandard socket outlets with USB charger
5 721 38A + plate 5 751 10A 5 721 39 + plate 5 751 70 5 726 62A + plate 5 754 71 5 710 94 + plate 5 754 46
Mechanisms supplied with rocker plates, to be equipped with special plates
Support frame not needed
Pack Cat.Nos Multistandard switched socket outlets Pack Cat.Nos Special plates for Arteor multistandard
16 A - 250 VA / 15 A - 127 VA with USB charger socket outlets with USB charger
Shuttered for child safety For 1-gang switched socket outlet
2P+E - 1-gang USB Type-A 3 A - 5 V= - 15 W
USB Type-A 3 A - 5 V= - 15 W 5 5 751 10A Neutral - White
5 5 751 44A Soft Alu
Consumption in passive mode < 0.07 W
5 5 751 43A Graphite
1 5 721 38A White 5 5 751 45A Magnesium
1 5 726 38A Magnesium 5 5 751 46A Champagne
1 5 710 83A Champagne 5 5 751 47A Dark Bronze
1 5 700 83A Soft Alu 1 5 751 16A Brushed Metal - Stainless Steel
2P+E - 1-gang For 1-gang switched socket outlet
USB Type-C 18 W USB Type-C 18 W
Fast charge feature: USB Type-C Power Delivery 5 5 754 67 Neutral - White
Consumption in passive mode < 0.07 W 5 5 754 68 Soft Alu
1 5 721 62A White Cover plates for socket outlets.
1 5 726 62A Wall & furniture mounted 5 5 754 69 Graphite
RED plates will be produced
Magnesium 5 5 754 71 Magnesium
1 5 722 62A Champagne socket outlets 1 gang & 2 gang 5 for BCOM project
5 754 72 Champagne
1 5 722 64A Soft Alu with USB Type C 5 5 754 73 Dark Bronze
1 5 754 74 Brushed Metal - Stainless Steel
2 x 2P+E - 2-gang
USB Type-A + Type-C 3 A - 5 V= - 15 W For 2-gang switched socket outlet
Consumption in passive mode < 0.07 W USB Type-A + Type-C 3 A - 5 V= - 15 W
1 5 721 39 White 5 5 751 70 Neutral - White
1 5 726 39 Magnesium 5 5 751 72 Soft Alu
1 5 710 84 Champagne 5 5 751 71 Graphite
1 5 700 84 Soft Alu 5 5 751 73 Magnesium
5 5 751 74 Champagne
5 5 751 75 Dark Bronze
2 x 2P+E - 2-gang 1 5 751 76 Brushed Metal - Stainless Steel
USB Type-A + Type-C 27 W
Fast charge feature: USB Type-C Power Delivery For 2-gang switched socket outlet
Consumption in passive mode < 0.07 W USB Type-A + Type-C 27 W
1 5 5 754 44 Neutral - White
5 722 87 White
1 5 5 754 46 Soft Alu
5 727 92 Magnesium 5
1 5 700 86 Champagne 5 754 45 Graphite
5 5 754 47 Magnesium
1 5 710 94 Soft Alu 5 5 754 48 Champagne
5 5 754 49 Dark Bronze
1 5 754 51 Brushed Metal - Stainless Steel
Red catalogue numbers: New products
573
87045 Limoges Cedex
Telephone: (+33) 05 55 06 87 87 - Fax:(+33) 05 55 06 88 88
TM Cat. No(s):5 721 62A/5 722 62A/5 722 64A/5 726 62A
Arteor 5 721 38A/5 726 38A/5 700 83A/5 710 83A
13A Multistandard Sockets with USB 5 722 87/5 700 86/5 710 94/5 727 92
Need to be equipped with special plate
5 721 62A
5 710 83A/5 700 83A 5 722 87/5 700 86 5 722 62A/64A
5 721 38A/5 726 38A 5 710 94/5 727 92 5 726 62A
1. USE
Multistandard switched sockets with USB for recharging portables devices such as smartphones, tablets, Mp3 or MP4 players, loudspeakers,
watches, game consoles, powerbanks, etc.Mechanism supplied with rocker plate, to be equipped with special plate.Support frame not
needed Shuttered for child safety.
2. RANGE
Designation White Magnesium Champagne Alu
2P+E 1 gang switched + 1 USB Type-A
(1 output Type-A) 5 721 38A 5 726 38A 5 710 83A 5 700 83A
2 x 2P+E 2 gang switched +1 USB Type-A + 1 USB
Type-C (1 output Type-A - 1 output Type-C) 5 722 87 5 727 92 5 700 86 5 710 94
1G Multistandard swithched socket + USB Type C
(1 output Type-C)
5 721 62A 5 726 62A 5 722 62A 5 722 64A
3. DIMENSIONS (mm) 5. TECHNICAL CHARACTERISTICS
C
B 5.1 Material characteristics
D
Base: PP
Cover-plate:PC
Self-extinguishing:
+ 850° C / 30 s for insulating parts holding live parts in place
+ 650° C / 30 s for other parts made of insulating materials
5.2 Electrical characteristics
A
Multistandard Socket:
Voltage: 127V~ Current: 15A
Voltage: 250V~ Current: 2.5/5/6/10/13/16A
Frequency:50/60Hz
References A B C D USB Chargers:
All values listed below are measured at an ambient temperature of + 25°
5 710 83A/5 700 83A/5 721 38A/5 726 38A 78.5 83.5 34.7 11.3
and after 15 minutes of operation.
5 722 87/5 700 86/5 710 94/5 727 92 83.5 143.2 31.5 11.3
Power 15W 18W 27W ( 2 USB )
5 721 62A/5 726 62A/5 722 62A/5 722 64A 78.5 83.5 34.7 11.3 Type Type A Type C Type A Type C
PD2.0/3.0/
Normal
*QC2.0/3.0/ QC2.0/3.0/FCP/
* SCP/AFC/ PD2.0/3.0/QC2.0/3.0/
*FCP/SCP/AFC/
Compatibility with fast
charging FCP/SCP/ APPLE 2.4A/ APPLE 2.4A/BC1.2
4. CONNECTION charge protocols details mode AFC/APPLE
2.4A/BC1.2
BC1.2
Nominal input voltage/ 220-250V~ 220-250V~ 220-250V~
Terminal types: with screw
Nominal input frequency 50/60 Hz 50/60 Hz 50/60 Hz
Terminal capacity: 4 X 2.5 mm²
3 X 4 mm² Nominal output voltage( ) 5 5 9 12 5 9 10 12 5 9 12 15 20 5 5
2 X 6 mm² Nominal output Current(A) 3 3 2 1.5 3 3 2 2.25 3 3 2.25 1.8 1.35 2.4 2.4
Recommended stripping length: 12 mm Maximum input current 300mA 500mA 800mA
Recommended terminal tightening torque: 0.5Nm Power average efficiency 85% 85.45% 87.5%
Maximum power
consumption in standy <0.1W
No-load consumption and average energy efficienvy: Level VI**
Protection class II - Low voltage
* PD : Power delivery QC : Quick Charge
Technical data sheet:F03961EN-00 Updated: Created: 27/04/2023
1/2
TM
Arteor Cat. No(s):5 721 62A/5 722 62A/5 722 64A/5 726 62A
5 721 38A/5 726 38A/5 700 83A/5 710 83A
13A Multistandard Sockets with USB 5 722 87/5 700 86/5 710 94/5 727 92
* Note : shared on A and C output
** Note : European Regulation No. 278/2009 of 6 April 2009, Directive
2005/32/EC on eco-design requirements for AC/DC power supplies.
Note : To optimize the charging time of your device, ensure to turn it
off during the charging phase.
5. TECHNICAL CHARACTERISTICS(continued)
5.3 Climatic characteristics
Storage temperatures: -20℃ to +70℃
Operating temperatures: -5℃ to +35℃
5.4 Mechanical characteristics
Impact test: IK02
Protection against solids & liquids: IP02
6. CLEANING
Surface cleaning with a soft, slightly damp cloth.
Do not use: acetone, tar remover, trichloroethylene
7. CONFORMITY - APPROVALS
Conform with installation and manufacturing standards.
Refer to e-catalogue.
Technical data sheet:F03961EN-00 Updated: Created:27/04/2023
2/2
1 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Ref. Certif. No.
FR_716289
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT
(IECEE) CB SCHEME
CB TEST CERTIFICATE
Product Fixed switched socket-outlet
Switched socket-outlets for fixed installations
Name and address of the applicant Legrand Intelligent Electrical (Huizhou) Co., Ltd.
Bldg. B1-B3, East No. 39 Hechang 6th Rd., HZZK Hi -tech
Industrial Development Zone, 516001 Huizhou
Guangdong - CHINA
Name and address of the manufacturer LEGRAND FRANCE
128 AVENUE DU MARECHAL DE LATTRE DE TASSIGNY
87045 LIMOGES CEDEX - FRANCE
Name and address of the factory
Note: When more than one factory, please report on page 2 Additional Information on page 2
Ratings and principal characteristics See Annex
Trademark / Brand (if any)
tenby
Model / Type Ref. See Annex
Ad ditional information (if necessary may also be Additional Information on page 2
reported on page 2)
A sample of the product was tested and found to IEC 60884-1:2002(ed.3) +A1:2006 +A2:2013
be in conformity with IEC 60884-2-3:2006
As shown in the Test Report Ref. No. which ARLI-ESH-P22071876
forms part of this Certificate
This CB Test Certificate is issued by the National Certification Body
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 31/01/2023 Signature: Julien GAUTHIER
Certification Officer
1/5
2 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Ref. Certif. No.
FR_716289
ANNEX
Name and address of the factories:
Legrand Intelligent Electrical (Huizhou) Co., Ltd.
Bldg. B1-B3, East No. 39 Hechang 6th Rd., HZZK Hi-tech Industrial Development Zone
516001 Huizhou, Guangdong CHINA
LEGRAND MAGYARORSZAG VILLAMOSSAGI RENDSZEREK ZRt
IPARTELEPI UT 14 PF 10, 6600 SZENTES - HUNGARY
LEGRAND ELECTRIC Ltd
UNIT 12 N° 1 INDUSTRIALL ESTATE MEDOMSLEY ROAD CONSETT
COUNTY DURHAM, DH8 6SR - UNITED KINGDOM
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 31/01/2023 Signature: Julien GAUTHIER
Certification Officer
2/5
3 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Ref. Certif. No.
FR_716289
ANNEX
Product References:
tenby for model 738145A; for all other models.
REFERENCES - MAIN CHARACTERISTICS
Reference Range* Product description Color of enclosure
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572129A Arteor WHITE
Made in China
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572629A Arteor MAGNESIUM
Made in China
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572229A Arteor CHAMPAGNE
Made in China
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572249A Arteor ALU
Made in China
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
678139A MOSAIC WHITE
Made in Hungary
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
730073A Synergy WHITE
Made in China
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
832073A Synergy BSS
Made in UK
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
832473A Synergy GOLD
Made in UK
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
832273A Synergy PSS
Made in UK
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
833073A Synergy BSS
Made in UK
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
833473A Synergy GOLD
Made in UK
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
833273A Synergy PSS
Made in UK
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
738145A Tenby WHITE
Made in China
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
617666A LINDBERGH WHITE
Made in China
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 31/01/2023 Signature: Julien GAUTHIER
Certification Officer
3/5
4 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Ref. Certif. No.
FR_716289
ANNEX
Reference Range* Product description Color of enclosure
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
617766A LINDBERGH ANTHRACITE
Made in China
1G BS 13A SP SWITCHED + USB TYPE C
617866A LINDBERGH CHAMPAGNE
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
281130AMW Mallia senses USB TYPE C 3A MATT WHITE
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
281130AMB Mallia senses USB TYPE C 3A MATT BLACK
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
281130ADS Mallia senses USB TYPE C 3A DARK SLIVER
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
281130ACH Mallia senses USB TYPE C 3A CHAMPAGNE
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
281130ADB Mallia senses USB TYPE C 3A DARK BRONZE
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
USB TYPE C 3A BRUSHED
281130ABA Mallia senses
ALUMINIUM
Made in China
1G BS 13A SINGLE POLE SWITCHED SOCKET +
281130ABB Mallia senses USB TYPE C 3A BRUSHED BLACK
Made in China
1G BS 13A SWITCHED SOCKET + USB TYPE C
282483A GALION CHARGER WHITE
Made in China
1G BS 13A SWITCHED SOCKET + USB TYPE C
282483A-C GALION CHARGER MATT BLACK
Made in China
1G BS 13A SWITCHED SOCKET + USB TYPE C
282483A-C1 GALION CHARGER ROSE GOLD
Made in China
1G BS 13A SWITCHED SOCKET + USB TYPE C
282483A-C2 GALION CHARGER CHAMPAGNE
Made in China
1G BS 13A SWITCHED SOCKET + USB TYPE C
282483A-C3 GALION CHARGER DARK SILVER
Made in China
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 31/01/2023 Signature: Julien GAUTHIER
Certification Officer
4/5
5 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Ref. Certif. No.
FR_716289
ANNEX
standard Sheet: standard sheet of BS 1363-2
rated current (A) 13A
rated voltage (V) 250V
degree of protection IP20
provision for earthing with earthing contact
method of connecting the cable rewirable
type of terminals screw-type
colour See the table above
socket-outlets
multiple socket-outlets
13A : 1
number of socket-outlets
degree of protection against electric shock normal protection
existence of shutters with shutters
method of application - mounting flush-type
design A (572129A, 572629A, 572229A, 572249A, 678139A,
832073A, 832473A, 832273A, 617666A, 617766A, 617866A,
281130AMW, 281130AMB, 281130ADS, 281130ACH,
method of installation
281130ADB, 281130ABA, 281130ABB, 282483A, 282483A - C,
282483A-C1, 282483A-C2, 282483A-C3) / design B (738145A,
730073A, 833073A, 833473A, 833273A)
Intended for circuits where a single earthing circuit provides protective earthing
Switched socket-outlets without interlock
According to the method of actuating the rocker
switch
According to the switching of the neutral unswitched neutral
type of components manufacturer Certification
Legrand Intelligent Electrical (Huizhou) LCIE test report No. ARLI-ESH-
USB charger
Co., Ltd. P22071902
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 31/01/2023 Signature: Julien GAUTHIER
Certification Officer
5/5
6 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Test Report issued under the responsibility
of:
TEST REPORT
IEC 60884-2-3
Plugs and socket-outlets for household and similar purposes
Part 2-3: Particular requirements for switched socket-outlets without
interlock for fixed installations
Report Reference No. .................... : ARLI-ESH-P22071876
Date of issue ................................... : January 31, 2023
Total number of pages ................... 94
Name of Testing Laboratory LCIE CHINA
preparing the Report ..................... : Building 4, No. 518, Xin Zhuan Road, CaoHejing Songjiang High-
Tech Park, Shanghai P.R.C (201612)
........................... : Legrand Intelligent Electrical (Huizhou) Co., Ltd.
Address ........................................... : Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK Hi-tech Industrial
Development Zone, Huizhou, Guangdong, CHINA
Test specification:
Standard.......................................... : IEC 60884-2-3:2006 with IEC 60884-1:2002, AMD1:2006,
AMD2:2013
Test procedure ............................... : CB Scheme
Non-standard test N/A
Test Report Form No. .................... : IEC60884_2_3C
Test Report Form(s) Originator .... : IMQ S.p.A.
Master TRF ..................................... : Dated 2017-10-31
Copyright © 2017 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
7 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 2 of 94 Report No. ARLI-ESH-P22071876
Test item description ....................... : Switched socket-outlets for fixed installations
Trade Mark ........................................ :
(for all models exclude 738145A), tenby (for
models 738145A)
Manufacturer .................................... : LEGRAND FRANCE
128, Avenue du Maréchal de Lattre de Tassigny 87045 LIMOGES
Cedex-France
Model/Type reference ...................... : 678139A, 730073A, 833073A, 833273A, 833473A, 832073A,
832273A, 832473A, 738145A, 617666A, 617766A, 617866A,
572129A, 572229A, 572249A, 572629A, 282483A, 282483A-C,
282483A-C1, 282483A-C2, 282483A-C3, 281130ABA, 281130ABB,
281130ACH, 281130ADB, 281130ADS, 281130AMB, 281130AMW
Ratings .............................................. : 13A 250V~
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
CB Testing Laboratory: LCIE CHINA
Testing location/ address ............................. : Building 4, No. 518, Xin Zhuan Road, CaoHejing Songjiang
High-Tech Park, Shanghai P.R.C (201612)
Tested by (name, function, signature) ........ : Project Engineer
Yan CAO
Approved by (name, function, signature) ... : PL Manager
Charlie CHEN
Testing procedure: CTF Stage 1:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 2:
Testing location/ address ............................. :
Tested by (name + signature) ...................... :
Witnessed by (name, function, signature) . :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 3:
Testing procedure: CTF Stage 4:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Witnessed by (name, function, signature) . :
TRF No. IEC60884_2_3C
8 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 3 of 94 Report No. ARLI-ESH-P22071876
Approved by (name, function, signature) ... :
Supervised by (name, function, signature) :
TRF No. IEC60884_2_3C
9 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 4 of 94 Report No. ARLI-ESH-P22071876
List of Attachments (including a total number of pages in each attachment):
- Dimension requirements (2 pages, from page 50 to page 51)
- pictures of product (43 pages, from page 52 to page 94)
Summary of testing:
Tests performed (name of test and test Testing location:
clause): LCIE CHINA
Full test on 572129A; Building 4, No. 518, Xin Zhuan Road, CaoHejing
Clauses 8, 9, 24 on 678139A; Songjiang High-Tech Park, Shanghai P.R.C
Clauses 8, 13, 27 on 730073A, 738145A & (201612)
617666A;
Clause 8 to 14, 24, 26, 27 on item 282483A &
281130AMW;
Marking check on other models.
Summary of compliance with National Differences (List of countries addressed):
N/A
The product fulfils the requirements of _________ (insert standard number and edition and
delete the text in parenthesis, leave it blank or delete the whole sentence, if not applicable)
TRF No. IEC60884_2_3C
10 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 5 of 94 Report No. ARLI-ESH-P22071876
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
, tenby
Trademark
Rating
Symbol for terminal
678139AA, 730073AA, 833073AA, 833273AA, 833473AA, 832073AA, 832273AA, 832473AA,
738145AA, 617666AA, 617766AA, 617866AA, 572129AA, 572229AA, 572249AA, 572629AA,
282483AA, 282483AA-C, 282483AA-C1, 282483AA-C2, 282483AA-C3, 281130AABA, 281130AABB,
281130AACH, 281130AADB, 281130AADS, 281130AAMB, 281130AAMW
Type reference (for reference)
TRF No. IEC60884_2_3C
11 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 6 of 94 Report No. ARLI-ESH-P22071876
Test item particulars .................................................. : Switched socket-outlets
Classification of installation and use ...................... : fixed installations
Supply Connection .................................................... : Screw type
Standard Sheet .......................................................... : BS 1363-2
Rated current (A) / Rated voltage (V) ..................... : 13A / 250V~
Degree of protection against access to hazardous IP2X / IP4X / IP5X
parts and against harmful ingress of solid foreign
objects ........................................................................ :
Degree of protection against harmful ingress of IPX0 / IPX4 / IPX5
water ........................................................................... :
Provision for earthing ............................................... : without earthing contact / with earthing contact
Method of connecting the cable ............................. : rewirable / non-rewirable
Type of cable ............................................................. : -
Nominal cross-sectional areas (mm2) ................... : -
Type of terminals ...................................................... : screw-type / screwless (rigid) / screwless (rigid and
flexible)
Type of connections ................................................. : soldered / welded / crimped / other
Socket-outlets:
Degree of protection against electric shock ......... : normal protection / increased protection
Existence of shutters ................................................ : without shutters / with shutters
Method of application / mounting of the socket- surface-type / flush-type / semi-flush-type / panel
outlet ........................................................................... : type / architrave-type / portable / table-type
(single/multiple) / floor recessed type / appliance
type
Method of installation ............................................... : design A (572129A, 572629A, 572229A, 572249A,
678139A, 832073A, 832473A, 832273A, 617666A,
617766A, 617866A, 281130AMW, 281130AMB,
281130ADS, 281130ACH, 281130ADB,
281130ABA, 281130ABB, 282483A, 282483A-C,
282483A-C1, 282483A-C2, 282483A-C3) / design B
(738145A, 730073A, 833073A, 833473A, 833273A)
Intended for circuits where ...................................... : a single earthing circuit provides protective earthing /
electrical noise immunity is desired for the earthing
circuit
Switched socket-outlets without interlock:
According to the method of actuating the switch : rotary / tumbler / rocker / push-button / cord operated
According to the switching of the neutral ............. : unswitched neutral
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
TRF No. IEC60884_2_3C
12 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 7 of 94 Report No. ARLI-ESH-P22071876
Date of receipt of test item ......................................... : July 29, 2022
Date (s) of performance of tests ............................... : July 29, 2022 to January 13, 2023
General remarks:
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Manufacture -clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Factory 1: Legrand Intelligent Electrical (Huizhou)
Co., Ltd.
Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK Hi-
tech Industrial Development Zone, Huizhou,
Guangdong, CHINA
Factory 2: LEGRAND MAGYARORSZAG
VILLAMOSSAGI RENDSZEREK ZRt.
IPARTELEPI UT 14 PF 10, 6600 SZENTES -
HUNGARY
Factory 3: Legrand Electric LTD.
Unit 12 No. 1 Industrial Estate, Medomsley Road,
Consett County Durham DH8 6SR, United Kingdom
General product information and other remarks:
13A 250V~, single pole switched socket-outlets, with single socket-outlet & single USB port
See following table for details:
Reference Range* Trademark Product description Color of enclosure
1G BS 13A SP SWITCHED
572129A Arteor SOCKET + USB TYPE C WHITE
Made in China
1G BS 13A SP SWITCHED
572629A Arteor SOCKET + USB TYPE C MAGNESIUM
Made in China
1G BS 13A SP SWITCHED
572229A Arteor SOCKET + USB TYPE C CHAMPAGNE
Made in China
TRF No. IEC60884_2_3C
13 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 8 of 94 Report No. ARLI-ESH-P22071876
1G BS 13A SP SWITCHED
572249A Arteor SOCKET + USB TYPE C ALU
Made in China
1G BS 13A SP SWITCHED
678139A MOSAIC SOCKET + USB TYPE C WHITE
Made in Hungary
1G BS 13A SP SWITCHED
730073A Synergy SOCKET + USB TYPE C WHITE
Made in China
1G BS 13A SP SWITCHED
832073A Synergy SOCKET + USB TYPE C BSS
Made in UK
1G BS 13A SP SWITCHED
832473A Synergy SOCKET + USB TYPE C GOLD
Made in UK
1G BS 13A SP SWITCHED
832273A Synergy SOCKET + USB TYPE C PSS
Made in UK
1G BS 13A SP SWITCHED
833073A Synergy SOCKET + USB TYPE C BSS
Made in UK
1G BS 13A SP SWITCHED
833473A Synergy SOCKET + USB TYPE C GOLD
Made in UK
1G BS 13A SP SWITCHED
833273A Synergy SOCKET + USB TYPE C PSS
Made in UK
1G BS 13A SP SWITCHED
738145A Tenby tenby SOCKET + USB TYPE C WHITE
Made in China
1G BS 13A SP SWITCHED
LINDBER
617666A SOCKET + USB TYPE C WHITE
GH
Made in China
1G BS 13A SP SWITCHED
LINDBER
617766A SOCKET + USB TYPE C ANTHRACITE
GH
Made in China
1G BS 13A SP SWITCHED +
LINDBER
617866A USB TYPE C CHAMPAGNE
GH
Made in China
1G BS 13A SINGLE POLE
281130AM Mallia SWITCHED SOCKET + USB
MATT WHITE
W senses TYPE C 3A
Made in China
1G BS 13A SINGLE POLE
281130AM Mallia SWITCHED SOCKET + USB
MATT BLACK
B senses TYPE C 3A
Made in China
1G BS 13A SINGLE POLE
281130AD Mallia SWITCHED SOCKET + USB
DARK SLIVER
S senses TYPE C 3A
Made in China
1G BS 13A SINGLE POLE
281130AC Mallia SWITCHED SOCKET + USB
CHAMPAGNE
H senses TYPE C 3A
Made in China
TRF No. IEC60884_2_3C
14 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 9 of 94 Report No. ARLI-ESH-P22071876
1G BS 13A SINGLE POLE
281130AD Mallia SWITCHED SOCKET + USB
DARK BRONZE
B senses TYPE C 3A
Made in China
1G BS 13A SINGLE POLE
281130AB Mallia SWITCHED SOCKET + USB BRUSHED
A senses TYPE C 3A ALUMINIUM
Made in China
1G BS 13A SINGLE POLE
281130AB Mallia SWITCHED SOCKET + USB
BRUSHED BLACK
B senses TYPE C 3A
Made in China
1G BS 13A SWITCHED SOCKET
282483A GALION + USB TYPE C CHARGER WHITE
Made in China
1G BS 13A SWITCHED SOCKET
282483A-
GALION + USB TYPE C CHARGER MATT BLACK
C
Made in China
1G BS 13A SWITCHED SOCKET
282483A-
GALION + USB TYPE C CHARGER ROSE GOLD
C1
Made in China
1G BS 13A SWITCHED SOCKET
282483A-
GALION + USB TYPE C CHARGER CHAMPAGNE
C2
Made in China
1G BS 13A SWITCHED SOCKET
282483A-
GALION + USB TYPE C CHARGER DARK SILVER
C3
Made in China
range
Component list:
Type
Components Manufacturer Characteristics standard Certified
reference
I/P: 100-250V~,
IEC 62368-1:2018;
Legrand 50/60Hz, 0.5A
EN IEC 62368- LCIE test
Intelligent O/P: 5.0VDC
B005399 1:2020+A11:2020; report No.
USB charger Electrical 3.0A, 9.0VDC
AA IEC 62368-3: 2017; ARLI-ESH-
(Huizhou) Co., 2.0A, 12.0VDC
EN IEC 62368-3: P22071902
Ltd. 1.5A, 18.0W
2020
Max
List of material
Object / Patr Manufacturer / Type / Technical Mark(s) of
Standard
No. Trademark model data conformity
SABIC Innovative
Plastics (China) Co.,
Plate, frame, Ltd.
under cover, Covestro (Shanghai) Test with
- PC IEC 60884-1
rocker, under Investment Co., Ltd. appliance
rocker Guangdong Htaso
New Materials
Technology Co.,Ltd
Legrand (Beijing)
Electrical Co., Ltd. IEC 60884-2- Test with
Base - PP
Shanghai Rizhisheng 3 appliance
Technology Co., Ltd.
TRF No. IEC60884_2_3C
15 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 10 of 94 Report No. ARLI-ESH-P22071876
Lowe's Metal
Technology
(Dongguan) Co., Ltd. Aluminum + IEC 60884-2- Test with
Metal plate SA -
SABIC Innovative PC 3 appliance
Plastics (China) Co.,
Ltd.
Huizhou Runhehui Steel IEC 60884-2- Test with
Metal frame -
Industrial Co., Ltd. SPCC 3 appliance
Legrand (Beijing)
Electrical Co., Ltd.
IEC 60884-2- Test with
Shutter Guangdong Htaso - PA
3 appliance
New Materials
Technology Co.,Ltd
Huizhou Jingyisheng
Steel IEC 60884-2- Test with
Shutter spring Precision Parts Co., -
Music wire 3 appliance
Ltd.
Huizhou Jinmiao
Technology Co., Ltd.
IEC 60884-2- Test with
Plunger Guangdong Htaso - PA
3 appliance
New Materials
Technology Co.,Ltd
Xiamen Yize Precision Steel IEC 60884-2- Test with
Switch spring -
Springs Co.,Ltd. 65Mn 3 appliance
Brass
Fuda Alloy Material IEC 60884-2- Test with
Moving contact - H62
Co.,Ltd. 3 appliance
copper:62%
Wenzhou Hongfeng Copper +
Electrical Alloy Co.,Ltd. Silver IEC 60884-2- Test with
Silver tip -
Fuda Alloy Material T2+AgNi(15) 3 appliance
Co.,Ltd. copper:>99%
Cangzhou Jinte
Hardware
Brass
L/N fixing Manufacturing Co., IEC 60884-2- Test with
- H62
contact Ltd. 3 appliance
copper:62%
Fuda Alloy Material
Co.,Ltd.
TIANJIN G-SHANK
Copper
PRECISION IEC 60884-2- Test with
L/N link - T2
MACHINERY 3 appliance
copper:>99%
CO.,LTD.
Cangzhou Jinte
Brass
Hardware IEC 60884-2- Test with
E link - H62
Manufacturing Co., 3 appliance
copper:62%
Ltd.
Bronze
Huizhou Runhehui IEC 60884-2- Test with
L/N/E contact - QSn6.5-0.1
Industrial Co., Ltd. 3 appliance
copper>58%
Guangdong Homelan Steel IEC 60884-2- Test with
Terminal -
Electrical Co., Ltd. DC04 3 appliance
Huizhou Taishenglong
Metal Products Co.,
Self-tapping Steel IEC 60884-2- Test with
Ltd. -
screw A3 3 appliance
Huizhou Guobang
Industrial Co., Ltd.
TRF No. IEC60884_2_3C
16 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 11 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
8 MARKING
8.1 Accessories marked as follows: P
- rated current (A) ....................................................: 13 P
- rated voltage (V) ....................................................: 250 P
- symbol for nature of supply ..................................: ~ P
- .....: , tenby P
- type reference .......................................................: See page 2 P
- symbol for degree of protection (first digit) if higher N/A
than 2 ........................................................................:
- symbol for degree of protection (second digit) if N/A
higher than 0.............................................................:
Socket-outlets with screwless terminals marked with the following: N/A
- the length of insulation to be removed .................: N/A
- an indication of the suitability to accept rigid N/A
conductors only (if any) ...........................................:
Switched socket-outlets without interlock: N/A
Symbol of mini-gap construction N/A
Symbol OFF position N/A
Symbol ON position N/A
8.2 Symbols used: as required in the standard P
Marking for the nature of supply placed next to the P
marking for rated current and rated voltage
Mini- N/A
open position (off) N/A
Closed position (on) N/A
8.3 Marking of fixed socket-outlets placed on the main part: P
- rated current, rated voltage and nature of supply P
- identification mark of the manufacturer or of the P
responsible vendor
- length of insulation to be removed, if any N/A
- type reference P
Cover plates necessary for safety purposes and N/A
intended to be sold separately: marked with the
type reference
IP code, if applicable: marked so as to be easily N/A
discernible
TRF No. IEC60884_2_3C
17 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 12 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Fixed socket-outlets classified according to item b) of N/A
7.2.5: identified by a triangle visible after installation
unless they have an interface configuration different
from that used in normal circuits .............................:
8.5 Neutral terminals: N ............................................. : N P
Earthing terminals: [earth symbol] ..........................: P
Markings not placed on screws or other easily P
removable parts
Terminals for conductors not forming part of the main function of the socket-outlet: N/A
- clearly identified unless their purpose is self- N/A
evident, or
- indicated in a wiring diagram fixed to the accessory N/A
Identification of such terminals may be achieved by: N/A
- their being marked with graphical symbols N/A
according to IEC 60417-2 or colours and/or
alphanumeric system, or
- their being marked with their physical dimensions N/A
or relative location
8.6 Surface-type mounting boxes forming an integral N/A
part of socket-outlets having IP>20: IP code
marked on the outside of its associated
enclosure so as to be easily discernible
8.7 Indication of which position or with which N/A
special provision the declared IP of flush-type
and semi-flush-type fixed socket-outlets having
IP>X0 is ensured
8.8 Marking durable and easily legible. Test: 15 s P
with water and 15 s with petroleum spirit
8.101 Terminals for phase conductors (supply P
conductors): identified unless method of
connection is of no importance, self-evident or
indicated on a wiring diagram
Such identification may take the form of a letter L or P
for more than one pole L1, L2, L3, etc., which may
be accompanied by arrow or arrows pointing to the
relevant terminal or terminals. L
Indications not placed on screws or other easily P
removable parts
8.102 Two, three, and four pole switches and switches N/A
having a rated voltage exceeding 250 V or a
rated current exceeding 16 A shall be so marked
that the direction of movement of the actuating
member to is different positions or the actual
switch position, is clearly indicated.
TRF No. IEC60884_2_3C
18 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 13 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Marking clearly visible on the front of the switch N/A
Not possible to fix cover, cover plate, or removable N/A
actuating members in an incorrect position
For the indication of the direction of movement of the N/A
operating means, symbols may be used
Closed position (on) shall be clearly indicated N/A
9 CHECKING OF DIMENSIONS
9.1 Accessories and surface-type mounting boxes P
comply with the appropriate standard sheets and
corresponding gauges, if any See Annex
Insertion of plugs into fixed or portable socket-outlets P
ensured by their compliance with the relevant
standard sheets
Compliance checked by measurement and by P
means of gauges with manufacturing tolerances as
shown in table 2 See Annex
9.2 It is not possible to engage a plug with: P
- a socket-outlet having a higher voltage rating or a P
lower current rating;
- a socket-outlet with a different number of live poles P
(exception admitted provided that no dangerous
situation can arise);
- a socket-outlet with earthing contact (plug for class P
0 equipment).
Engagement of a plug for class 0 or class I P
equipment with a socket-outlet designed to accept
plugs for class II equipment, not possible
Impossibility of insertion checked by applying a gauge, for 1 min, with a force of: P
- 150 N (rated current 16A); P
- 250 N (rated current 16A) N/A
Accessories with electrometric or thermoplastic P
material: test carried out at (35 2) °C
9.3 Deviations from standard sheets made only if N/A
they provide technical advantage and do not
affect the purpose and safety of accessories
complying with standard sheet
10 PROTECTION AGAINST ELECTRIC SHOCK
10.1 Socket-outlets: live parts not accessible P
Test with test probe B of IEC 61032 P
TRF No. IEC60884_2_3C
19 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 14 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Accessories with electrometric or thermoplastic P
material: additional test carried out at (35 2) °C
with test probe 11 of IEC 61032 (75 N for 1 min)
During the test: accessories not deform and no live P
parts accessible
10.2 Accessible parts (with exception of small screws P
and the like for fixing bases and covers or cover
plates): made of insulating material
Cover or cover plates of fixed socket-outlets and P
accessible parts of plugs and portable socket-
outlets: made of metal if the requirements of 10.2.1
or 10.2.2 are fulfilled
10.2.1 Accessible metal parts or accessible metal parts P
protected by supplementary insulation made by
insulating linings or insulating barriers
Insulating linings or insulating barriers cannot be P
removed without being permanently damaged
Insulating linings or insulating barriers cannot be P
replaced in an incorrect position and, if they are
omitted, accessories are rendered inoperable or
manifestly incomplete
There is no risk of accidental contact between live P
parts and metal covers or cover plates
10.2.2 Accessible metal parts are reliably connected, P
through a low-resistance connection, to the earth
during fixing
10.3 Contact between a pin of a plug and a live P
socket-contact of a socket-outlet not possible
while any other pin is accessible
Compliance checked by manual test and by means P
of gauges with tolerances as specified in table 2
Accessories with electrometric or thermoplastic P
material: test carried out at (35 2) °C
Socket-outlets with enclosure or bodies of rubber or P
polyvinyl chloride: test carried out with a force of 75
N for 1 min
Fixed socket-outlets provided with metal covers or N/A
cover plates: clearance of at least 2 mm required
between a pin and a socket-contact when another
pin(s) is(are) in contact with the metal covers or
cover plates (mm) ....................................................:
10.4 External parts of plugs made of insulating N/A
material
Overall dimensions of rings around pins not exceed N/A
8 mm concentric with respect to the pin
TRF No. IEC60884_2_3C
20 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 15 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
10.5 Shuttered socket-outlets: live parts not P
accessible, without a plug in engagement, with
the gauges shown in figure 9 and 10
Live contacts automatically screened when the plug P
is withdrawn
Shutters so designed that a plug is inserted with the P
same movement in a socket outlet with shutters as
in a socket-outlet without shutters
Means cannot easily be operated by anything other P
than a plug and not depend upon parts which are
liable to be lost
Gauge of figure 9, applied to the entry holes P
corresponding to live contacts with a force of 20 N,
for approximately 5 s, successively in three
directions, does not touch live parts
Steel gauge of figure 10, applied to the entry holes P
corresponding to live contacts with a force of 1 N for
approximately 5 s, in three directions, does not
touch live parts
Accessories with electrometric or thermoplastic P
material: test carried out at (35 2) °C
10.6 Earthing contacts of a socket-outlet designed P
that they cannot be deformed by the insertion of
a plug
Test plug inserted into the socket-outlet with a force of 150 N for 1 min P
Earthing contacts of a socket-outlet designed that P
they cannot be deformed by the insertion of a plug
After this test: socket-outlet still comply with the P
requirements of clause 9
10.7 Socket-outlet with or without lid with increased N/A
protection: live parts not accessible
Test wire of 1 mm diameter (figure 10) applied with a N/A
force of 1 N on all accessible surfaces does not
touch live parts
Accessories with electrometric or thermoplastic N/A
material: test carried out at (35 2) °C
Socket-outlet tested without a plug N/A
inserted with the lid, if any, open
10.101 Knobs, operating levers, push buttons, rockers P
and the like: of insulating material, unless:
- accessible metal parts separated from metal parts P
of mechanism by double or reinforced insulation, or
- reliably connected to earth N/A
TRF No. IEC60884_2_3C
21 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 16 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
10.102 Metal parts of the switch mechanism, which are N/A
not insulated from live parts, shall not protrude
from the enclosure.
10.103 Metal parts of the switch mechanism, shall not N/A
be accessible when the switched socket-outlet
with interlock is mounted as for normal use.
In addition, these metal parts shall be insulated from N/A
accessible metal parts.
This additional requirement does not apply if the N/A
metal parts of the mechanism are separated from
live parts or
If they are reliably connected to earth. N/A
11 PROVISION FOR EARTHING
11.1 Earth connection made before the current- P
carrying contacts of the plug become live
Current-carrying pins are separated before the earth P
connection is broken
11.2 Earthing terminals of rewirable accessories P
comply with clause 12
Earthing terminals of the same size as the P
corresponding terminals for the supply conductors
Earthing terminals of rewirable accessories: internal P
Earthing terminals of fixed socket-outlets: fixed to the P
base or to a part reliably fixed to the base
Earthing terminals of fixed socket-outlets: fixed to the P
base or to a part reliably fixed to the base
Earthing contacts of fixed socket-outlets: P
- fixed to the base, or P
- fixed to the cover (reliably connected to the N/A
earthing terminals; contact pieces silver plated or
with adequate protection)
Parts of earthing circuit in one piece or reliably P
connected by riveting, welding, or the like
11.3 Accessible metal parts of fixed socket-outlets: N/A
permanently and reliably connected to the
earthing terminal
11.4 Socket-outlets, having an IP>X0, with enclosure of insulating material and more N/A
than one cable inlet, provided with:
- an internal fixed earthing terminal, or N/A
TRF No. IEC60884_2_3C
22 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 17 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- adequate space for a floating terminal (test N/A
connection using the type of terminal specified by
the manufacturer), unless
- earthing terminal of socket-outlet itself allows the N/A
connection of an incoming and an outgoing earthing
conductor
11.5 Connection between earthing terminal and P
accessible metal parts: of low resistance
Test current equal to 1,5 times the rated current or 25A
25 A (A) ................................................................... :
Resistance not exceed 0,05 ( ) ........................ : 0,02 P
11.6 Fixed socket-outlets according to item b) of N/A
7.2.5: earthing socket contact and its terminal
electrically separated from any metal mounting
means or other exposed conductive parts which
may be connected to the protective earthing
circuit of the installation
12 TERMINALS AND TERMINATIONS
All the test on terminals, with the exception of the P
tests of 12.3 11 and 12.3.12, made after the test of
clause 16
12.1 General P
12.1.1 Rewirable fixed socket-outlets provided with screw- P
type terminals or with screwless terminals ............ : screw-type terminals
Pre-soldered flexible conductors used: pre-soldered N/A
area outside the clamp area of screw-type terminals
Clamping means of terminals: not serve to fix any P
other components
12.1.2 Non-rewirable accessories provided with soldered, N/A
welded, crimped or equally effective permanent
connections (termination) ....................................... :
Screwed or snap-on connections not used N/A
Connections made by crimping a pre-soldered N/A
flexible conductor not permitted
12.2 Terminals with screw clamping for external copper conductors P
12.2.1 Accessories provided with terminals which allows P
the proper connection of copper conductors as
shows in table 3
Rated current (A); Type of accessories ................. : 13
Type of conductor (rigid / flexible) .......................... : rigid / flexible
Smallest / largest cross-sectional area (mm2) ....... : 1,5 / 2,5 / 4
TRF No. IEC60884_2_3C
23 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 18 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Diameter of the largest conductor (mm) ................ : 2,72
Figure of terminal ................................................... : 2
Minimum diameter D (minimum dimensions) of required (mm): 3,6mm P
conductor space: required (mm); measured (mm) : measured (mm): 4,2mm
12.2.2 Terminals allow the conductor to be connected P
without special preparation
12.2.3 Terminals have adequate mechanical strength P
Screws and nut for clamping the conductors have P
metric ISO thread or a comparable thread
Screws not of soft metal such as zinc or aluminium P
12.2.4 Terminals resistant to corrosion P
12.2.5 Terminals clamp the conductor(s) without undue P
damage See appended table 12.2.5
During the test: conductor not slip out, no break near P
clamping unit and no damage
12.2.6 Terminals clamp the conductor reliably between P
metal surfaces See appended table 12.2.6
During the test: conductor not move noticeably P
12.2.7 Terminals designed or placed that the conductor P
cannot slip out while the clamping screws or nuts are
tightened See appended table 12.2.7
After the test: no wire of the conductor escaped from P
the clamping unit
12.2.8 Terminals not work loose from their fixing to P
accessories
Torque test (screws and nuts tightened and loosened 5 times): P
- rated current (A) ................................................... : 13
- copper conductor of the largest cross-sectional
area (mm²) (table 3) ............................................... : 4
- type of conductor (solid or stranded) ................... : solid or stranded
- torque (Nm) (table 6 or appropriate figures 2, 3 or
4) ............................................................................. : 1,2
During the test: terminals not work loose and show P
no damage
12.2.9 Clamping screws or nuts of earthing terminals: P
adequately locked against accidental loosening, not
possible to loosen them without the aid of a tool
12.2.10 Earthing terminals: no risk of corrosion P
Body of brass or other metal no less resistant to P
corrosion
TRF No. IEC60884_2_3C
24 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 19 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
The body is a part of a frame or enclosure of N/A
aluminium alloy: precautions are taken to avoid the
risk of corrosion
12.2.11 Pillar terminals: distance g no less than the value P
specified in figure 2: required (mm); measured (mm) required (mm): 1,8mm
................................................................................. : measured (mm): min. 4,5 mm
Mantle terminals: distance g no less than the value N/A
specified in figure 5: required (mm); measured (mm)
................................................................................. :
12.3 Screwless terminals for external copper conductors N/A
12.3.1 Screwless terminals of the type suitable for: N/A
- for rigid copper conductors only, or N/A
- for both rigid and flexible copper conductors (tests N/A
carried out with rigid and then repeated with flexible
conductors)
12.3.2 Screwless terminals provided with two clamping N/A
units each allowing the proper connection of rigid or
of rigid and flexible conductors having nominal
cross-sectional areas from 1,5 up to 2,5 mm 2 (table
7)
Two conductors to be connected: each conductor N/A
introduced in a separate clamping unit
12.3.3 Screwless terminals allow the conductor to be N/A
connected without special preparation
12.3.4 Parts of screwless terminals intended for carrying N/A
current of materials as specified in 26.5
12.3.5 Screwless terminals clamp specified conductors with N/A
sufficient contact pressure without undue damage to
the conductor
Conductor clamped between metal surfaces N/A
12.3.6 It is clear how the connection and disconnection of N/A
the conductors is to be made
Disconnection of a conductor require an operation, N/A
other than a pull, so that can be made manually with
or without a general-purpose tool
It is not possible to confuse the opening intended for N/A
the use of a tool with the opening intended for the
conductor
12.3.7 Screwless terminals intended for the interconnection of two or more conductors: N/A
- during insertion, operation of clamping means of N/A
one of the conductors is independent of operation of
that for the other conductor(s);
TRF No. IEC60884_2_3C
25 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 20 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- during the connection or disconnection the N/A
conductors can be connected or disconnected either
at the same time or separately
- each conductor introduced in a separate clamping N/A
unit.
- it is possible to clamp securely any number of N/A
conductors up to the maximum as designed.
Number of conductors; Nominal cross-sectional area
(mm2) ...................................................................... :
12.3.8 Screwless terminals of fixed socket-outlets: N/A
adequate insertion obvious and over-insertion
prevented
12.3.9 Screwless terminals properly fixed to the socket- N/A
outlets
Not work loose when conductors are connected or N/A
disconnected
Self-hardening resins used to fix terminals not N/A
subject to mechanical stress
12.3.10 Screwless terminals withstand mechanical stresses N/A
occurring in normal use See appended table 12.3.10
During application of the pull conductor not come out N/A
of the terminal
Additional test with apparatus shown in figure 11 See appended table 12.3.10 N/A
During the test: conductors not moved noticeably in N/A
the clamping unit
After these tests: neither terminals nor clamping N/A
means have worked loose and conductors show no
deterioration
12.3.11 Screwless terminals withstand electrical and thermal N/A
stresses occurring in normal use See appended table 12.3.11
After the test: inspection show no changes N/A
Repetition of mechanical strength test according to N/A
12.3.10 See appended table 12.3.11
During application of the pull conductor not come out N/A
of the terminal
Additional test with apparatus shown in figure 11 See appended table 12.3.11 N/A
During the test: conductors not moved noticeably in N/A
the clamping unit
After these tests: neither terminals nor clamping N/A
means have worked loose and conductors show no
deterioration
TRF No. IEC60884_2_3C
26 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 21 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
12.3.12 Screwless terminals: connected rigid solid conductor N/A
remains clamped, even when deflected during
normal installation See appended table 12.3.12
13 CONSTRUCTION OF FIXED SOCKET-OUTLETS
13.1 Socket-contact assembly have sufficient P
resilience to ensure adequate contact pressure
on plug pins
Part of socket-contact assembly ensure metallic P
opposing contacts at least on two sides of each pins
13.2 Socket-contact and pin(s) of socket-outlet which P
are made of copper or copper alloy, as specified
in 26.5, are considered as complying with this
requirement
The pin(s) of socket-outlets so constructed in such a N/A
way that the mechanical strength of the pin(s) does
not depend on the plastic material
Compliance is checked by inspection and in case of N/A
doubt by the tests of 14.2 and Clause 21 on a new
set of specimens without plastic
13.3 Insulating linings, barriers and the like: P
adequate mechanical strength
13.4 Socket-outlets constructed as to permit P
- easy introduction into the terminal and reliable P
connection of the conductors in the terminals,
except for lead wires of pilot lights
- easy fixing of the main part to a wall or in a P
mounting box
- correct positioning of the conductors P
- adequate space between the underside of the main P
part and the surface on which the main part is
mounted;
- adequate space between the sides of the main part P
and the enclosure (cover or box);
Socket-outlets having screwless terminals, N/A
constructed that the connecting and/or disconnecting
means of the screwless terminals cannot be
activated by the conductors during and after
installation
Compliance is checked by inspection and in case of N/A
doubt by the following test
TRF No. IEC60884_2_3C
27 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 22 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
The test is carried out with a solid copper conductor N/A
having the smallest cross-sectional area, as
specified in 12.3.2.
(mm2
If it is not possible to exert a force onto the N/A
connecting/disconnecting device, the product is
deemed to comply with the requirements without
further tests.
During the application of the pull, the conductor do N/A
not come out of the screwless terminal
In addition socket-outlets classified as design A: N/A
permit easy positioning and removal of the cover or
cover plate, without displacing the conductors or
activating the connecting and/or disconnecting
means of screwless terminals.
Compliance is checked by inspection and by an N/A
installation test with conductors of the largest
nominal cross-sectional area specified in Table 3
(mm2
13.5 Socket-outlets designed that full engagement of P
associated plugs is not prevented by any
projection from their engagement face
Gap between the engagement face of the socket- P
outlet and the plug: not exceed 1 mm
13.6 Covers provided with bushings for the entry N/A
holes for the pins: not possible to remove them
from the outside or for them to become
detached inadvertently from the inside when
the cover is removed
13.7 Covers, cover-plates or parts of them intended to ensure protection against P
electric shock:
- held in place at two or more points by effective P
fixings
- fixed by means of a single fixing, for example, by a N/A
screw, provided that they are Iocated by another
means (for example, by a shouIder)
Fixings of covers or cover-plates of socket-outlets P
of design A serve to fix the main parts: there are
means to maintain the base in position, even after
removal of the covers or cover-plates
13.7.1 Covers or cover-plates whose fixings are of the screw-type: N/A
Compliance checked by inspection only N/A
13.7.2 Covers or cover-plates whose fixing is not dependent on screws and whose N/A
removal is obtained by applying a force in a direction approximately perpendicular
to the mounting/supporting surface:
TRF No. IEC60884_2_3C
28 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 23 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Compliance checked, when their removal may give access, with the standard test N/A
finger:
to live parts: by the test of 24.14 (verification of the N/A
non-removal and the removal)
to non-earthed metal parts separated from live N/A
parts in such a way that creepage distances and
clearances have the values shown in table 23: by
the test of 24.15 (verification of the non-removal
and the removal)
only to parts of insulating material, or earthed metal N/A
parts, or metal parts separated from live parts in
such a way that creepage distances and
clearances have twice the values shown in table
23, or live parts of SEL V circuits not greater than
25 V a.c.: by the test of 24.16 (verification of the
non-removal and the removal)
13.7.3 Covers or cover-plates the fixing of which is not dependent on screws and whose P
removal is obtained by using a tool, in accordance with the manufacturer's
instructions given in an instruction sheet or in other documentation:
Compliance checked, when their removal may give access, with the standard test P
finger:
to live parts: by the test of 24.14 (verification of the N/A
non-removal only)
to non-earthed metal parts separated from live N/A
parts in such a way that creepage distances and
clearances have the values shown in table 23: by
the test of 24.15 (verification of the non-removal
only)
only to parts of insulating material, or earthed metal P
parts, or metal parts separated from live parts in
such a way that creepage distances and
clearances have twice the values shown in table
23, or live parts of SEL V circuits not greater than
25 V a.c.: by the test of 24.16 (verification of the
non-removal only)
13.8 Cover-plate intended for a socket-outlet with N/A
earthing contact: not interchangeable with a
cover-plate intended for a socket-outlet without
earthing contact
13.9 Surface-type socket-outlets: no free openings in N/A
their enclosures
Drain holes, small gaps between enclosures or N/A
boxes and conduits, cables, or earthing
contacts, if any, or between enclosures or boxes
and grommets or membranes and knockouts
are neglected provided they do not compromise the
declared IP rating.
TRF No. IEC60884_2_3C
29 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 24 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
13.10 Screws or other means for mounting the N/A
socket-outlet on a surface in a box or
enclosure: easily accessible from the front
Fixing means not serve any other fixing purpose N/A
13.11 Multiple socket-outlets with a common base: N/A
provided with fixed links for the inte rconnection
of the contacts in parallel
Fixing of the links independent from the connection N/A
of the supply wires
13.12 Multiple socket-outlets, comprising separate N/A
bases: correct position of each base ensured
Fixing of each base independent of the fixing of the N/A
combination to the mounting surface
13.13 Mounting plate of surface-type socket-outlets: N/A
adequate mechanical strength
13.14 Socket-outlets withstand the lateral strain P
imposed by equipment likely to be introduced
into them
Socket-outlets 16A 250V: test made 4 times with the P
socket-outlet turned through 90°, 5 N for 1 min
(device shown in fig. 13)
During the test: device not become disengaged from P
the socket-outlet
After the test: P
- no damage P
- socket-outlets comply with clause 22 P
13.15 Socket-outlets are not an integraI part of P
lampholders
13.16 Surface-type socket-outlets having IP>20 are N/A
according to their IP classification when fitted
with conduits or with sheathed cables and
without a plug in engagement
Surface-type socket-outlets having a degree of N/A
protection from IPX4 to IPX6 shall have
provision for opening a drain hole.
Socket-outlets with a drain hole: drain hole is not N/A
less than 5 mm in diameter, or 20 mm 2 in area with
a width and a length of not less than 3 mm ..........:
Drain hole: effective N/A
Lid springs (if any): of corrosion-resistant material N/A
(bronze or stainless steel) ......................................:
13.17 Earthing pins: adequate mechanical strength N/A
TRF No. IEC60884_2_3C
30 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 25 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Not solid pins: compliance checked by inspection N/A
and by the test of 14.2 made after the tests of clause
21
13.18 Earthing contacts, phase contacts and neutral contacts : P
- locked against rotation; P
- when the product is ready for the wiring do not P
possible to be removed without the use of a tool
13.19 Metal strips of the earthing circuit: no burrs P
which might damage the insulation of the
supply conductors
13.20 Socket-outlets to be installed in a box: P
designed that the conductor ends can be
prepared after the box is mounted in position,
but before the socket-outlet is fitted in the box
13.21 lnlet openings: allow the introduction of the N/A
conduit or the sheath of the cable
Surface-type socket-outlets: N/A
the conduit or sheath of the cable can en ter at least N/A
I mm into the enclosure
inlet opening for conduit entries, or at least two of N/A
them if there are more than one, capable of
accepting conduit sizes of 16, 20, 25 or 32
according to IEC 60423 or a combination of at least
two of any of these sizes
inlet opening for cable entries capable of accepting N/A
cables having the dimensions specified in table 14
or be as specified by the manufacturer: rated
current (A); Limits of external dimensions of cable
min/max (mm) .........................................................:
13.22 Membranes (grommets) in inlet openings: N/A
reliably fixed and not displaced by the
mechanical and thermal stresses occurring in
normal use
Test on membranes subjected to the ageing treatment specified in 16.1 and N/A
assembled in the accessories
Accessories placed at (40 2) °C for 2 h. Force of N/A
30 N applied for 5 s by test probe 11 of IEC 61032.
During the test: no deformation
Membranes likely to be subjected to an axial pull: N/A
axial pull of 30 N applied for 5 s. During the test:
membranes not become detached
After the test: no harmful deformation, cracks or N/A
similar damage
TRF No. IEC60884_2_3C
31 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 26 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Test repeated with membranes not subjected to N/A
any treatment
13.23 Membranes in inlet openings: introduction of N/A
the cables into the accessory permitted when
the ambient temperature is low
Test on membranes not subjected to the ageing treatment specified in 16.1 and N/A
assembled in the accessories
Accessories kept at (-15 2) °C for 2 h: possibility N/A
to introduce cables of the largest diameter through
membranes
After the test: no harmful deformation, cracks or N/A
similar damage
13.101 Switches shall be constructed to match the P
number of poles of the socket-outlet, except
that the neutral pole is not switched in
unswitched neutral socket-outlets.
The earthing contact is not considered as a pole P
and the earth circuit shall not be switched
The position of the switch operating member shall P
be such that it does not prevent, nor shall its correct
operation be prevented by, the proper insertion of
the corresponding plug or plugs.
13.102 Knobs of rotary switches shall be securely N/A
coupled to the shaft or the part operating the
mechanism.
The knob is subjected for 1 min to an axial pull of N/A
100 N.
After, knob having only one direction of operation N/A
are turned 100 times in the reverse direction.
Knob shall not become detached N/A
13.103 The actuating member of a switch, when P
released, shall automatically take up the
position corresponding
Single push-button the actuating member may take N/A
up a single rest position.
13.104 Switches shall be so constructed that the P
moving contacts can come to rest only in the
Intermediate position permissible if: N/A
- it corresponds to the intermediate position of the N/A
actuating member, and
- the insulation between fixed and moving contacts N/A
is adequate. Electric strength test as specified in 500 V / 750 V / 1250 V /
17.2: test voltage a.c. for 1 min (V) ..................... : 2000 V
TRF No. IEC60884_2_3C
32 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 27 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
13.105 Switches shall be constructed so that undue P
arcing cannot occur when the switch is
operated slowly.
Compliance is checked by: P
After the test of clause 21, to break the circuit a P
further ten times
During the test, no sustained arcing shall occur. P
13.106 Switched socket-outlets with switches N/A
operating more than one pole shall make and
break all poles simultaneously.
Switched neutral, the neutral shall not make after or N/A
break before other poles.
13.107 The action of the mechanism, if the cover or P
cover plates are removable for installation
purposes, shall be independent of the presence
of the covers or cover plates.
14 CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OTLETS N/A
15 INTERLOCKED SOCKET-OUTLETS N/A
16 RESISTANCE TO AGEING, PROTECTION PROVIDED BY ENCLOSURES, AND
RESISTANCE TO HUMIDITY
16.1 Resistance to ageing P
Accessories are resistant to ageing P
For accessories having a lid, the lid is closed during P
the test
Accessories subjected to a test in a heating cabinet P
at (70 2) °C for seven days (168 h)
After the tests, the specimens show: P
- no crack visible with normal or corrected vision P
without additional magnification
- no sticky or greasy material P
- no trace of cloth (forefinger pressed with 5 N) P
- no damage P
16.2 Protection provided by enclosures P
Enclosures provide a degree of protection in P
accordance with the IP designation of the
accessory IP20
16.2.1 Protection against access to hazardous parts and against harmful effects due to P
ingress of solid foreign objects
TRF No. IEC60884_2_3C
33 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 28 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Accessories and their enclosures provide a degree P
of protection against access to hazardous parts and
against harmful effects due to ingress of solid
foreign objects
Fixed socket-outlets: mounted as in normal use on P
a vertical surface
Flush-type and semi-flush type socket-outlets: P
mounted in an appropriate box according to the
Accessories with screwed glands or membranes fitted with flexible cables within the N/A
range specified in table 3:
- largest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
- smallest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
Glands tightened with a torque equal to 2/3 of the
torque applied during the test of 24.6 (Nm) ..........:
Screws of the enclosure tightened with a torque
equal to 2/3 of the torque given in table 6 (Nm) ...:
16.2.1.1 Protection against access to hazardous parts P
Appropriate test performed as specified in IEC P
60529 (see also clause 10) IP20
16.2.1.2 Protection against harmful effects due to ingress of solid foreign objects N/A
Appropriate test performed as specified in IEC N/A
60529
Test on accessories with IP5X (considered to be of N/A
category 2): dust not penetrated in a quantity to
interfere with satisfactory operation or to impair
safety
Test on accessories with IP6X (considered to be of N/A
category 1): dust do not penetrate
16.2.2 Protection against harmful effects due to ingress of water N/A
Accessories and their enclosures provide a degree N/A
of protection against harmful effects due to ingress
of water in accordance with their IP classification
Appropriate test performed as specified in IEC 60529 under the following N/A
conditions:
Flush-type and semi-flush type socket-outlets: fixed N/A
in a vertical test wall using an appropriate box
Accessory suitable to be installed on a rough wall: N/A
test wall according to figure 15 is used
TRF No. IEC60884_2_3C
34 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 29 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Surface-type socket-outlets mounted as for normal use in a vertical position and N/A
fitted with cables (having conductors of the largest and smallest nominal cross-
sectional area given in table 3) or conduits or both in accordance with the
- largest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
- smallest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
Screws of enclosure tightened with a torque equal
to 2/3 of the torque given in table 6 (Nm) .............:
Glands tightened with a torque equal to 2/3 of the
torque applied during the test of 24.6 (Nm) ..........:
Accessory with drain holes opened during the test: N/A
any accumulation of water proved by inspection
Socket-outlets tested without a plug in engagement N/A
of the same system and with the same degree of
protection against harmful effects due to ingress of
water
Specimens withstand an electric strength test N/A
specified in 17.2 which is started within 5 min of
completion of the IP test
16.3 Resistance to humidity P
Accessories proof against humidity which may P
occur in normal use
Compliance checked by a humidity treatment P
carried out in a humidity cabinet containing air with
relative humidity maintained between 91 % and
95 %
Specimens kept in the cabinet for: P
- two days (48 h) for accessories having IPX0 P
- seven days (168 h) for accessories having IP>X0 N/A
After this treatment the specimens show no P
damage
17 INSULATION RESISTANCE AND ELECTRIC STRENGTH
17.1 Insulation resistance measured 1 min after P
application of 500 V d.c. See appended table 17.1
17.2 Electric strength: a.c. test voltage applied for 1 P
min See appended table 17.2
18 OPERATION OF EARTHING CONTACTS
TRF No. IEC60884_2_3C
35 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 30 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Earthing contacts provide adequate contact P
pressure and not deteriorate in normal use
Compliance checked by the tests of clauses 19 and P
21
19 TEMPERATURE RISE
Accessories constructed that they comply with the following temperature rise test P
Non-rewirable accessories are tested as delivered N/A
In the case of multiple socket-outlets, the test is P
carried out on one socket-outlet of each type and
current rating with the test current as specified in
Table 20 passed through that one socket-outlet See appended tables
The temperature rise of the terminals, terminations P
and clamping units according to Figure 44
determined by means of thermocouples do not
exceed 45 K See appended tables
19.1 Socket-outlets are tested as follows: N/A
Socket-outlets tested using a test plug with brass N/A
pins having the minimum specified dimensions See appended table 19.1
For this test the temperature rise is measured on N/A
the terminals and terminations.
19.2 Fixed socket-outlets of a socket-outlet and fused plug system are tested as P
follows:
a) For a single socket-outlet the plug is inserted into p
the socket-outlet and 70 % of the test current is
passed through the plug See appended table 19.2
The balance of the total test current is passed, p
simultaneously through a looped connection,
connected to the socket-outlet terminals
The total nominal load on the supply cable is P
passed for 60 min See appended table 19.2
b) For a multiple socket-outlet a plug is inserted into N/A
one socket-outlet and 70 % of the test current is
passed See appended table 19.2
A second plug is inserted into another socket-outlet N/A
and the balance of the total test current is passed
See appended table 19.2
The total nominal load on the supply cable is N/A
passed for 60 min. See appended table 19.2
20 BREAKING CAPACITY
Accessories have adequate breaking capacity P
TRF No. IEC60884_2_3C
36 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 31 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Compliance checked by testing: P
- socket-outlets; See appended table 20 P
Multiple socket-outlets: test carried out on one N/A
socket-outlet of each type and current rating
During the test: no sustained arcing occur P
After the test: P
- specimens show no damage impairing their P
further use;
- entry holes for the pins not show any damage P
which may impair the safety
Addition: Switches incorporated in switched socket-outlets P
shall have adequate making and breaking capacity
- nominal cross-sectional area as for the test of P
clause 17 (mm2) ........................................................ : 1,5
6 alternating current P
- test voltage (1,1 Vn) (V) ......................................... : 275 P
- test current (1,25 In) (A) ......................................... : 16,25 P
- 200 operations; rate (operations per minute) ....... : 15 P
Rotary switches intended to be operated in either N/A
direction, the actuating member is turned in one
direction for half the total number of operations, and
in the reverse direction for the remainder
During the test: no sustained arcing nor welding of P
the contacts
After the test: specimens show no damage P
21 NORMAL OPERATION
Accessories withstand without excessive wear or P
other harmful effect, the mechanical, electrical and
thermal stresses occurring in normal use
Compliance checked by testing: P
- socket-outlets; See appended table 21 P
Test performed according to the procedure
specified in Figure 43; point of Figure 43 at which
the test program has begun (1, 2, 3) .....................: 1
Test current passed: P
- during each insertion and withdrawal of the plug P
(In 16A)
- during alternate insertion and withdrawal, the N/A
other insertion and withdrawal being made without
current flowing (In > 16A)
TRF No. IEC60884_2_3C
37 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 32 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Multiple socket-outlets: test carried out on one N/A
socket-outlet of each type and current rating
During the test: no sustained arcing occur P
After the test the specimens do not show: P
- wear impairing their further use; P
- deterioration of enclosures, insulating lining or P
barriers;
- damage to the entry holes for the pins, that might P
impair proper working;
- loosening of electrical or mechanical connections; P
- seepage of sealing compound N/A
Shuttered socket-outlets: gauges of figure 9 and 10 P
applied to the entry holes corresponding to live
contacts do not touch live parts when they remain
under the relevant forces See appended table 21
Temperature-rise test (requirements of clause 19) See appended table 21 P
Electric strength (sub-clause 17.2) See appended table 21 P
Addition: Switches incorporated in switched socket-outlets P
shall withstand, without excessive wear or other
harmful effect, the mechanical, electrical and
thermal stresses occurring in normal use
- nominal cross-sectional area as for the test P
o(mm²) : 1,5
P
- test voltage (Vn) (V) ................................................: 250 P
- test current (In) (A) ..................................................: 13 P
- number of operations per table 101 : 40000 P
Rotary switches intended to be operated in either P
direction, the actuating member is turned in one
direction for half the total number of operations, and
in the reverse direction for the remainder
During the test the specimens shall function correctly P
Reduced electric strength per clause 17 without P
humidity treatment See appended table 21 bis
Temperature rise test per clause 19 after normal P
operation See appended table 21 bis
After the tests the specimens not show: P
- wear impairing their further use; P
- discrepancy between the position of the actuating P
member (if indicated) and that of the moving
contacts
TRF No. IEC60884_2_3C
38 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 33 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- deterioration of enclosures, insulating lining or P
barriers;
- seepage of sealing compound N/A
- loosening of electrical or mechanical connections; P
- displacement of moving contacts of switches P
22 FORCE NECESSARY TO WITHDRAW THE
PLUG
Construction of accessory does allow the easy P
insertion and withdrawal of the plug, and prevent
the plug from working out of the socket-outlet in
normal use
22.1 Verification of the maximum withdrawal force P
22.2 Verification of the minimum withdrawal force P
23 FLEXIBLE CABLES AND THEIR CONNECTIONS N/A
24 MECHANICAL STRENGTH
Accessories, surface mounting boxes, screwed P
glands and shrouds have adequate mechanical
strength
24.1 Fixed socket-outlets, and surface-type P
mounting boxes: hammer test described in IEC
60068-2-75 (test EHA), equivalent mass of 250 g See appended table 24.1
After the test: no damage, live parts no become P
accessible
24.3 Main parts of surface-type socket-outlets: first fixed to a cylinder of rigid steel N/A
sheet and then fixed to a flat steel sheet
During and after the tests: no damage N/A
24.6 Screwed glands of accessories having IP>20: torque test (1 min) N/A
- diameter of test rod (mm) ................................... :
- type of material (metal / moulded) ...................... :
- torque (Nm) .......................................................... :
After the test: no damage of glands and enclosures N/A
of the specimens
24.8 Shuttered socket-outlets: mechanical test carried out on specimens P
submitted to the normal operation test according to clause 21
Force (40 N / 75 N) applied for 1 min against the
shutter of an entry hole by means of one pin (N) : 75
Pin did not come in contact with live parts P
TRF No. IEC60884_2_3C
39 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 34 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
After the test: no damage P
24.14 Forces necessary to retain or remove covers, cover-plates or parts of them N/A
(accessibility with the test finger to live parts)
24.14.1 Verification of the retention of covers or cover-plates (fixed socket-outlets) N/A
Force (40 N / 80 N) applied for 1 min perpendicular
to the mounting surface (N) .................................. : 80 N
Covers or cover-plates did not come off N/A
Test repeated on new specimens with a sheet of N/A
hard material, (1 ± 0,1) mm thick, fitted around the
supporting frame (fig. 31): covers or cover-plates
did not come off
After the test: no damage N/A
24.14.2 Verification of the removal of covers or cover-plates (fixed socket-outlets) N/A
Force not exceeding 120 N applied 10 times N/A
perpendicular to the mounting / supporting surface:
covers or cover-plates came off
Test repeated on new specimens with a sheet of N/A
hard material, (1 ± 0,1) mm thick, fitted around the
supporting frame (fig. 31): covers or cover-plates
came off
After the test: no damage N/A
24.14.3 Verification of the retention of covers or cover-plates (plugs and portable socket- N/A
outlets)
Force 80 N applied for 1 min perpendicular to the N/A
mounting surface: covers, cover-plates or parts of
them did not come off
Test repeated with a force of 120 N: N/A
Rewirable plugs and rewirable portable socket- N/A
outlets: covers, cover-plates or parts of them came
off but the specimen showed no damage
Non-rewirable, non-moulded-on accessories: N/A
covers, cover-plates or parts of them came off but
the accessories were permanently useless
according to 14.1
24.15 Force necessary for covers or cover-plates to come off or not to come off N/A
(accessibility with the test finger to non-earthed metal parts separated from
live parts by creepage distances and clearances according to table 23)
24.14.1 Verification of the non-removal of covers or cover-plates N/A
Force (10 N / 20 N) applied for 1 min in direction
perpendicular to the mounting surface (N) .......... : 20N
Covers or cover-plates did not come off N/A
TRF No. IEC60884_2_3C
40 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 35 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Test repeated on new specimens with a sheet of N/A
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates did not come off
After the test: no damage N/A
24.14.2 Verification of the removal of covers or cover-plates N/A
Force not exceeding 120 N applied 10 times in N/A
direction perpendicular to the mounting / supporting
surface: covers or cover-plates came off
Test repeated on new specimens with a sheet of N/A
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates came off
After the test: no damage N/A
24.16 Force necessary for covers or cover-plates to come off or not to come off P
(accessibility to insulating parts, earthed metal parts, live parts of SELV 25
V a.c. or metal parts separated from live parts by creepage distances twice
those according to table 23)
24.14.1 Verification of the non-removal of covers or cover-plates P
Force 10 N applied for 1 min in direction P
perpendicular to the mounting surface: covers or
cover-plates did not come off
Test repeated on new specimens with a sheet of P
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates did not come off
After the test: no damage P
24.14.2 Verification of the removal of covers or cover-plates N/A
Force not exceeding 120 N applied 10 times in N/A
direction perpendicular to the mounting / supporting
surface: covers or cover-plates came off
Test repeated on new specimens with a sheet of N/A
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates came off
After the test: no damage N/A
24.17 Test with gauge of figure 7 applied according to complying / not complying
figure 9 for verification of the outline of covers
or cover-plates: distances between face C of
gauge and outline of side under test, not
decrease ................................................................ :
24.18 Test with gauge according to figure 5 applied as complying / not complying
shown in figure 11 (1 N): gauge not enter more
than 1mm .............................................................. :
TRF No. IEC60884_2_3C
41 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 36 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
24.19 Shroud of portable socket-outlets: compression test (20 2) N at (25 5) °C by N/A
means of the apparatus shown in figure 38
After 1 min and while the shrouds are still under N/A
pressure the dimensions did comply with the
appropriate standard sheet
Test repeated with the specimen rotated 90 ° N/A
25 RESISTANCE TO HEAT
25.1 Specimens kept for 1 h in a heating cabinet at (100 2) °C for 1 h P
During the test: no change impairing their further use P
and sealing compound, if any, not flow
After the test: P
- no access to live parts with probe B of IEC 61032 P
applied with a force not exceeding 5 N
- markings still legible P
25.2 Parts of insulating material necessary to retain P
current-carrying parts and parts of the earthing
circuit in position, as well as parts of the front
surface zone, 2 mm wide, surrounding the phase
and neutral pin entry holes: ball-pressure test at
(125 2)°C for 1 h See appended table 25.2
25.3 Parts of insulating material not necessary to P
retain current-carrying parts and parts of the
earthing circuit in position, even though in
contact with them: ball-pressure test (1 h) See appended table 25.3
26 SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS
26.1 Connections withstand mechanical stresses P
Thread-forming or thread-cutting screws used only P
if supplied together with the piece in which they are
intended to be inserted
Thread-cutting screws intended to be used during N/A
installation: captive
Screws and nuts which transmit contact pressure: P
in engagement with a metal thread
Threaded part torque test See appended table 26.1 P
26.2 Screws in engagement with a thread of N/A
insulating material: correct introduction into the
screw hole or nut ensured
TRF No. IEC60884_2_3C
42 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 37 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
26.3 Contact pressure: not transmitted through P
insulating material other than ceramic, pure
mica or other material no less suitable unless
there is sufficient resiliency in metallic parts
Connections made by insulation piercing of tinsel N/A
cord reliable
26.4 Screws and rivets locked against loosening P
and/or turning
26.5 Current-carrying parts (including earthing terminals) have mechanical strength, P
electrical conductivity and resistance to corrosion adequate:
- copper; N/A
- alloy with at least 58 % copper for parts made from P
cold-rolled sheet or with at least 50 % copper for
other parts;
- stainless steel with at least 13 % chromium and not N/A
more than 0,09 % carbon
- steel with electroplated coating of zinc (ISO 2081): N/A
service condition ISO no. (1/2/3); IP (X0/X4/X5);
thickness (µm) ........................................................... :
- steel with electroplated coating of nickel and N/A
chromium (ISO 1456): service condition ISO no.
(2/3/4); IP (X0/X4/X5); thickness (µm) ...................... :
- steel with electroplated coating of tin (ISO 2093): N/A
service condition ISO no. (2/3/4); IP (X0/X4/X5);
thickness (µm) ........................................................... :
Current-carrying parts subjected to mechanical P
wear: not of steel with electroplated coating
Metals having a great difference of electrochemical P
potential: not used in contact with each other
26.6 Contacts subjected to a sliding action are of P
metal resistant to corrosion
26.7 Thread-forming screws and thread-cutting N/A
screws are not used for the connection of
current-carrying parts
Thread-forming screws and thread-cutting screws N/A
used to provide earthing connection: it is not
necessary to disturb the connection and at least two
screws are used for each connection
27 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH
SEALING COMPOUND
27.1 Creepage distances, clearances and distances P
through sealing compound are not less than the
values shown in table 23 See appended table 27.1
TRF No. IEC60884_2_3C
43 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 38 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
27.2 Insulating sealing compound does not protrude N/A
above the edge of the cavity in which it is
contained
27.3 Surface-type socket-outlets do not have bare N/A
current-carrying strips at the back
27.101 For switches incorporated in switched socket- P
outlets, creepage distances, clearances and
distances through sealing compound shall be
not less than the values shown in table 102
28 RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND
TO TRACKING
28.1 Resistance to abnormal heat and to fire P
28.1.1 Glow-wire test according to IEC 60695-2-10 and IEC P
60695-2-11 See appended table 28.1.1
28.2 Resistance to tracking N/A
Parts of insulating material retaining live parts in N/A
position of accessories having IP>X0: of material
resistant to tracking
Tracking test at 175 V with solution A of IEC 60112 See appended table 28.2 N/A
29 RESISTANCE TO RUSTING
Ferrous parts protected against rusting P
Test made after having removed all grease using a suitable degreasing agent: 10 P
min 10 % solution of ammonium chloride, 10 min in a box with air saturated with
moisture and 10 min at (100 5) °C:
No signs of rust P
30 ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES N/A
TRF No. IEC60884_2_3C
44 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 39 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
12.2.5 TABLE: test with apparatus shown in figure 11 (screw-type terminals) P
rated current (A) ...................................................... : 13
type of conductors .................................................. : rigid solid / rigid stranded /
flexible
smallest/largest cross-sectional area per table 3
(mm2) ......................................................................... : 1,5 /2,5/ 4
number of conductors ............................................. : 1/3/2
nominal diameter of thread (mm); torque per
table 6 (Nm) .............................................................. : 1,2
Diameter of
Cross-sectional Height H per table 9
bushing hole per Mass (kg) Remarks
area (mm2) (mm)
table 9 (mm)
1,5 6,5 260 0,4 P
2,5 9,5 280 0,7 P
4 9,5 280 0,9 P
supplementary information:
12.2.6 TABLE: pull test (screw-type terminals) P
rated current (A) ...................................................... : 13
smallest/largest cross-sectional area per table 3
(mm2) ......................................................................... : 1,5 /2,5/ 4
nominal diameter of thread (mm); torque 2/3 per
table 6 (Nm) .............................................................. : 0,8
Type of conductors Pull per table 4
Cross-sectional Number of
(rigid solid / rigid applied for 1 min Remarks
area (mm2) conductors
stranded / flexible) (N)
rigid solid / rigid
1,5 1 40 P
stranded
rigid solid / rigid
2,5 3 50 P
stranded
rigid solid / rigid
4 2 50 P
stranded
supplementary information:
12.2.7 TABLE: tightening test (screw-type terminals) P
rated current (A) ...................................................... : 13
nominal diameter of thread (mm); torque 2/3 per
table 6 (Nm) .............................................................. : 0,8
TRF No. IEC60884_2_3C
45 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 40 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Number of wires
Largest cross- Permissible Type of conductors
and nominal
sectional area per number of (rigid solid / rigid Remarks
diameter of wires
table 3 (mm2) conductors (1) stranded / flexible)
per table 5
2,5 3 rigid solid 1 × 1,78 P
2,5 3 rigid stranded 7 × 0,67 P
4 2 rigid solid 1 × 2,25 P
4 2 rigid stranded 7 × 0,86 P
supplementary information: (1) terminals intended for looping-in 2 or 3 conductors
12.3.10 TABLE: mechanical strength test (screwless-type terminals) N/A
rated current (A) ...................................................... :
largest/smallest cross-sectional area per table 7
(mm2) ......................................................................... :
Number of connection (after Type of conductor (solid / Cross-sectional Remarks
that conductor subjected to a rigid stranded / flexible area (mm2)
pull of 30 N for 1 min) /
disconnection
TABLE: test with apparatus shown in figure 11 N/A
Type of Diameter of
Cross-
conductor (solid bushing hole Height H per
sectional area Mass (kg) Remarks
/ rigid stranded / per table 9 table 9 (mm)
(mm2)
flexible (mm)
supplementary information:
12.3.11 TABLE: electrical and thermal strength test (screwless-type terminals) N/A
Test a) Test carried out for 1 h connecting rigid solid conductors: N/A
test current per table 10 (A) ................................... :
nominal cross-sectional area (mm2) ..................... :
Screwless terminal number Voltage drop (mV) Required voltage drop (mV)
1 15
2 15
3 15
4 15
TRF No. IEC60884_2_3C
46 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 41 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
5 15
Test b) Temperature cycles test carried out on terminals subjected to Test a): N/A
test current per table 10 (A) ................................... :
nominal cross-sectional area (mm2) ..................... :
allowed voltage drop (mV) ..................................... : 22,5 mV or 2 times 24th cycle
value (mV)
Screwless terminal number 1 2 3 4 5 Remarks
th
voltage drop after 24 cycle
voltage drop after 48th cycle
voltage drop after 72nd cycle
voltage drop after 96th cycle
voltage drop after 120th cycle
voltage drop after 144th cycle
voltage drop after 168th cycle
voltage drop after 192nd cycle
12.3.10 TABLE: mechanical strength test (screwless-type terminals) N/A
rated current (A) ...................................................... :
largest/smallest cross-sectional area per table 7
(mm2) ......................................................................... :
Number of connection (after Type of conductor (solid / Cross-sectional Remarks
that conductor subjected to a rigid stranded / flexible area (mm2)
pull of 30 N for 1 min) /
disconnection
TABLE: test with apparatus shown in figure 11 N/A
Type of Diameter of
Cross-
conductor (solid bushing hole Height H per
sectional area Mass (kg) Remarks
/ rigid stranded / per table 9 table 9 (mm)
(mm2)
flexible (mm)
supplementary information:
12.3.12 TABLE: deflection test (principle of test apparatus shown in figure 12a) N/A
Test carried out connecting rigid solid copper conductors: N/A
test current (A) (equal rated current) .................... :
TRF No. IEC60884_2_3C
47 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 42 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
required voltage drop (mV) .................................... : 25 mV
Type of conductor Smallest Largest Remarks
cross-sectional area per table 11 (mm2)
force per table 12 (N)
screwless terminal number 1 2 3 1 2 3
starting point (X = deflection original X X+10° X+20° X X+10° X+20°
point)
voltage drop 1st deflection (mV)
voltage drop 2nd deflection (mV)
voltage drop 3rd deflection (mV)
voltage drop 4th deflection (mV)
voltage drop 5th deflection (mV)
voltage drop 6th deflection (mV)
voltage drop 7th deflection (mV)
voltage drop 8th deflection (mV)
voltage drop 9th deflection (mV)
voltage drop 10th deflection (mV)
voltage drop 11th deflection (mV)
voltage drop 12th deflection (mV)
supplementary information:
17.1 TABLE: insulation resistance P
Test voltage applied between: Item per 17.1 measured (M ) required (M )
a) between all poles connected together and the body, the 5000
measurement being made with a plug in engagement
b) between each pole in turn and all others, these being 5000
connected to the body with a plug in engagement
f) between all poles connected together and the body, with the 5000
switch in the closed position (on);
g) between each pole in turn and all others connected to the 5000
body, with the switch in the closed position (on);
h) between the terminals which are electrically connected 5000
together when the switch is in the closed position (on), the switch
being in the open position (off).
supplementary information:
17.2 TABLE: electric strength
TRF No. IEC60884_2_3C
48 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 43 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
rated voltage (V) ...................................................... : 250V~
flashover /
Test voltage applied between: item per 17.1 test voltage (V) breakdown
(Yes/No)
a) between all poles connected together and the body, 2000 No
the measurement being made with a plug in
engagement
b) between each pole in turn and all others, these 2000 No
being connected to the body with a plug in
engagement
f) between all poles connected together and the body, 2000 No
with the switch in the closed position (on);
g) between each pole in turn and all others connected 2000 No
to the body, with the switch in the closed position
(on);
h) between the terminals which are electrically 2000 No
connected together when the switch is in the closed
position (on), the switch being in the open position
(off).
supplementary information:
19.1 TABLE: temperature rise test N/A
rated current of accessory (A) .............................. :
type of accessory ................................................... :
nominal cross-sectional area per table 15 (mm2)
(rewirable accessories) / type of conductor ........ :
type of conductors (rigid solid / rigid stranded /
flexible) (rewirable accessories) ........................... :
nominal diameter of thread (mm); torque 2/3 of
that specified in 12.2.8 (Nm) (rewirable
accessories) ............................................................. :
temperature
number of
test rise of
conductors
current measured allowed external
and nominal test circuit
specimen (table dT dT parts of
cross- (L-L/L-N/L-E)
20) for 1 (K) (K) insulating
sectional area
h (A) material
(mm2)
(25.3)
supplementary information:
TRF No. IEC60884_2_3C
49 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 44 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
19.2 TABLE: temperature rise test for fixed socket-outlets of a socket-outlet and P
fused plug system
rated current of accessory (A) .............................. : 13
type of accessory (non-rewirable / rewirable) .... : rewirable
nominal cross-sectional area per table 15 (mm2) : 1,5
type of conductors (rigid solid / rigid stranded /
flexible) ...................................................................... : rigid solid
nominal diameter of thread (mm); torque 2/3 of
that specified in 12.2.8 (Nm.................................... : 0,8
Test a) single socket-outlet P
70% of
number of 30% of test
test
conductors test current
test current
type of and nominal current (table 20) measured allowed parts of
circuit (table 20)
specimen flexible cable cross- (table 20) for 1 h insulating
(L-L/L- for 1 h
(1) sectional for 1 h (supply material
N/L-E) (socket-
area (mm2) (looped) cable) (25.3)(K)
outlet)
(1) (A) (A)
(A)
A - 3x1,5 L-N 14 6 20 Max. 26 Max. 7
B - 3x1,5 L-N 14 6 20 Max. 35 Max. 6
C - 3x1,5 L-N 14 6 20 Max. 36 Max. 8
A - 3x1,5 L-E 14 6 20 Max. 26 Max. 7
B - 3x1,5 L-E 14 6 20 Max. 34 Max. 6
C - 3x1,5 L-E 14 6 20 Max. 36 Max. 8
supplementary information:
Non-rewirable accessories
(1)
Test b) multiple socket-outlet N/A
70% of test 30% of test
number of
current test current
conductors
test circuit (table 20) current (table 20) measured allowed parts of
type of flexible and nominal
specimen (L-L/L-N/L- for 1 h (1st (table 20) for 1 h insulating
cable (1) cross-
E) socket- for 1 h (2nd (supply material
sectional area
outlet) socket) cable) (25.3)(K)
(mm2) (1)
(A) (A) (A)
TRF No. IEC60884_2_3C
50 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 45 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
supplementary information:
Non-rewirable accessories
(1)
20 TABLE: breaking capacity P
rating of accessory (A/V) ....................................... : 13/250
type of accessory .................................................. : Fixed
nominal cross-sectional area per table 15 (mm2) /
type of conductor .................................................... : 1,5
type of conductors (rigid solid / rigid stranded /
flexible) ...................................................................... : rigid solid
nominal diameter of thread (mm); torque 2/3 of
that specified in 12.2.8 (Nm) (rewirable
accessories) ............................................................. : 0,8
rate of operation (strokes per minute) ................ : 30
test plug (for each number
type and current number of of
test number
rating of socket-
test strokes, strokes,
current of
outlet)
voltage with without
specimen (1,25 In) strokes remarks
(1,1 Vn) shutters shutters
pin pin cos 0,6 (plugs
(V) with with
dimensions spacing (A) only)
current (1) current
(mm) (mm) (2)
A 4,05 x 6,48 22,23 275 16,25 - 100 - - P
B 4,05 x 6,48 22,23 275 16,25 - 100 - - P
C 4,05 x 6,48 22,23 275 16,25 - 100 - - P
supplementary information:
(1) starting point 1 or 3 of Figure 43
(2) starting point 2 of Figure 43
21 TABLE: normal operation P
rating of accessory (A/V) ....................................... : 13/250
type of accessory .................................................. : Fixed
nominal cross-sectional area per table 15 (mm2) /
type of conductor .................................................... : 1,5
type of conductors (rigid solid / rigid stranded /
flexible) ...................................................................... : rigid solid
nominal diameter of thread (mm); torque 2/3 of
that specified in 12.2.8 (Nm) .................................. : 0,8
rate of operation (strokes per minute) ................ : 30
TRF No. IEC60884_2_3C
51 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 46 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
test plug (for each number
number
type and current of
number of of
rating of socket- test number strokes,
test strokes, strokes,
outlet) current of with
voltage with without
specimen (table 20), strokes shutters
(Vn) shutters shutters
pin pin cos 0,8 (plugs
(V) with with
dimensions spacing (A) only) without
current (1) current
(mm) (mm) (2) current
(3)
A 4,05 x 6,48 22,23 250 13 - 10000 - - P
B 4,05 x 6,48 22,23 250 13 - 10000 - - P
C 4,05 x 6,48 22,23 250 13 - 10000 - - P
TABLE: test for shuttered socket-outlets P
Gauge of figure 9, applied with a force of Steel gauge of figure 10, applied with
specimen 20 N, for approximately 5 s, successively a force of 1 N for approximately 5 s,
in three directions in three directions
A Not touch live parts Not touch live parts P
B Not touch live parts Not touch live parts P
C Not touch live parts Not touch live parts P
19 TABLE: temperature rise test
test current (table 20 for
test circuit measured dT allowed dT
specimen clause 21) for 1 h
(L-L/L-N/L-E) (K) (K)
(A)
A L-N 13 Max. 35 45 P
B L-N 13 Max. 37 45 P
C L-N 13 Max. 39 45 P
A L-E 13 Max. 39 45 P
B L-E 13 Max. 37 45 P
C L-E 13 Max. 38 45 P
17.2 TABLE: electric strength
flashover /
item per
specimen test voltage applied between: test voltage (V) breakdown
17.1
(Yes/No)
A, B, C a) between all poles connected together 1500 No
and the body
A, B, C b) between each pole in turn and all 1500 No
others
supplementary information: (1) starting point 1 or 3 of Figure 43 ; (2) starting point 2 of Figure 43;
(3) starting point 1 or 2 of Figure 43
TRF No. IEC60884_2_3C
52 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 47 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
21 (bis) TABLE: reduced electric strength after normal operation (for switches) P
flashover /
item per
test voltage applied between: test voltage (V) breakdown
17.1
(Yes/No)
f) between all poles connected together and the body, 1500 No
with the switch in the closed position (on);
g) between each pole in turn and all others connected to 1500 No
the body, with the switch in the closed position (on);
h) between the terminals which are electrically 1500 No
connected together when the switch is in the closed
position (on), the switch being in the open position
(off).
TABLE: temperature rise measurements at terminals after normal operation P
(for switches)
test current (In) passed for 1 h (A) .......................: 13
max. measured allowed
thermocouple locations temperature rise temperature rise
(K) (K)
Terminal L Max. 29K 45
Terminal N N/A -
supplementary information:
22 TABLE: force necessary to withdraw the plug P
Rated current (A) .................................................... : 13
Number of poles ..................................................... : 3
22.1 Verification of the maximum withdrawal force P
socket-outlets (multi-pin gauge)
specimen maximum withdrawal force the test plug did not remain in the socket-outlet
(N) (Y/N)
A 50 Y (not remain) P
B 50 Y (not remain) P
C 50 Y (not remain) P
22.2 Verification of the minimum withdrawal force
socket-outlets (single-pin gauge)
specimen minimum withdrawal force the test pin gauge did not fall from each
(N) individual contact-assembly within 30 s (Y/N)
A 1,5 Y (not fall) P
B 1,5 Y (not fall) P
TRF No. IEC60884_2_3C
53 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 48 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
C 1,5 Y (not fall) P
supplementary information:
24.1 TABLE: impact test P
part of enclosure tested
blows per part height of fall (mm) comments
per table 21 (A, B, C, D)
A 5 80 P
B 4 120 P
supplementary information:
25.2 TABLE: ball pressure test of insulating materials P
allowed impression diameter (mm) ......................: 2 mm
test temperature impression
part under test
( C) diameter (mm)
Material retain current parts & earthing circuit 125 1,3
supplementary information:
25.3 TABLE: ball pressure test of insulating materials
allowed impression diameter (mm) ......................: 2 mm
test temperature impression
part under test
( C) (1) diameter (mm)
Enclosure (cover) 70 1,0
Shutter part 77 0,6
supplementary information: (1) (70 ± 2) °C / (40 ± 2) °C + highest temperature rise determined during the test
of clause 19
26.1 TABLE: threaded part torque test P
diameter of column
applied times
threaded part identification thread number no damage
torque (Nm) (5/10)
(mm) (1, 2 or 3)
Terminal L, N & E 3,9 2 1,2 5 No damage
supplementary information:
27.1 TABLE: creepage distances, clearances and distances through sealing P
compound
rated voltage (V) ...................................................... : 250
TRF No. IEC60884_2_3C
54 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 49 of 94 Report No. ARLI-ESH-P22071876
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
creepage distance dcr, clearance required required
item per required
dcr dcr dtsc dtsc
table 23
cl and distance through sealing cl (mm) cl (mm) (mm) (mm)
compound dtsc at/of: (mm) (mm)
1, 6 between live parts of different polarity 3 > 3 (by 3 > 3 (by - -
gauge) gauge)
2, 7 between live parts and accessible 3 > 3 (by 3 > 3 (by - -
surface of parts of insulating material gauge) gauge)
2, 7 between live parts and earthed metal 3 > 3 (by 3 > 3 (by - -
parts including parts of earthing gauge) gauge)
circuit
creepage distance dcr, clearance require require require
item per dcr dtsc
cl and distance through sealing d cl (mm) d dcr d dtsc
table 102 (mm) (mm)
compound dtsc at/of: cl (mm) (mm) (mm)
1), 4) Between live parts which are 3 > 3 (by 3 > 3 (by - -
separated when the contacts are gauge) gauge)
open
supplementary information:
28.1.1 TABLE: glow-wire test
visible
flame and
test flame and ignition of
material glowing
part under test temperature sustained the tissue
designation extinction
( C) glowing paper (Y/N)
time
(Y/N)
Enclosure (cover) - 650 N 0 N
Shutter - 650 N 0 N
Material retain current parts &
- 850 Y 5s N
earthing circuit
supplementary information:
28.2 TABLE: resistance to tracking N/A
number of drops ...................................................... : 50
flashover /
test voltage
part under test material designation breakdown
(V)
(Yes/No)
175
supplementary information:
TRF No. IEC60884_2_3C
55 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 50 of 94 Report No. ARLI-ESH-P22071876
Attachment Nº 1
Dimension requirements of Standard BS 1363-2
Clause Requirement Test Result - Remark Verdict
13.1 The disposition of the socket contacts was as P
follow:
E
N L
No projection on the engagement surface of the P
socket-outlet.
The spacing of the socket conta P
was used to test the contacts.
13.2 P
neutral socket contact satisfactory with the
corresponding pins of the plug.
13.3 - P
travel of current-carrying pin in any position the
socket contacts might occupy, not less than
9.6mm.
13.9 The apertures for line, neutral and earth plug
pins
Sample 1 Sample 2 Sample 3 Spec (mm)
L (mm) 7,2x4,8 7,2x4,8 7,2x4,8 7,2 4,8 P
N (mm) 7,2x4,8 7,2x4,8 7,2x4,8 7,2 4,8 P
E (mm) 8,8x4,8 8,8x4,8 8,8x4,8 8,8 4,8 P
13.10 The distance from the apertures of line and L (mm) N (mm) P
neutral to the periphery of the engagement face.
1. >15mm >15mm
Spec: 9,5mm 2. >15mm >15mm
3. >15mm >15mm
13.12 Multiple socket- P
gauge test.
13.14 Conductive component parts of socket-outlet P
were so located and separated that, in normal
use, they were not displaced so as to affect
adversely the safety or proper operation of the
socket-outlet.
13.15 For flush socket-outlets intended to be used in P
enclosures complying with BS 4662 were such
that the clearance for the purpose of wiring
between the base or bases and the inside walls
of the box were not less than 6mm.
The clearance between the overall depth of the P
base of the bottom of a 35mm deep box were not
less than 14mm.
There were no live metal protruding from or flush P
with the socket-outlet base.
13.16 Flush-mounted socket plates intended for Dimension (mm) P
mounting on boxes, The distance between the
1. 60,1mm
two screws at centre,
TRF No. IEC60884_2_3C
56 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 51 of 94 Report No. ARLI-ESH-P22071876
Clause Requirement Test Result - Remark Verdict
Spec = 60,3mm 0,2mm for 1 gang 2. 60,2mm
= 120,6mm 0,3mm for 2 gang 3. 60,1mm
13.17 Dimension for flush socket-outlet pates either of Dimension (mm) P
insulating material or metal,
1. Min.85,0mm x min.85mm
Spec 82,5mm x 82,5mm for 1 gang 2. Min.85,0mm x min.85mm
82,5mm x 142,5mm for 2 gang 3. Min.85,0mm x min.85mm
13.18 Non-rewireable portable socket-outlets were N/A
permanently attached to each other.
The base and cover of rewireable portable N/A
socket-outlets were firmly secured to each other.
13.20 For non-rewireable portable socket-outlets N/A
means were provided to prevent loose strands of
conductor connected to current-carrying parts
from reducing the minimum insulation thickness
requirements between such parts and all
accessible external surface of the socket-outlet.
TRF No. IEC60884_2_3C
57 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 52 of 94 Report No. ARLI-ESH-P22071876
Attachment Nº 2
Pictures
572129A
572129A
TRF No. IEC60884_2_3C
58 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 53 of 94 Report No. ARLI-ESH-P22071876
572129A
Cover plate for 572129A
TRF No. IEC60884_2_3C
59 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 54 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 572129A
572229A
TRF No. IEC60884_2_3C
60 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 55 of 94 Report No. ARLI-ESH-P22071876
572229A
Cover plate for 572229A
TRF No. IEC60884_2_3C
61 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 56 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 572229A
572629A
TRF No. IEC60884_2_3C
62 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 57 of 94 Report No. ARLI-ESH-P22071876
572629A
Cover plate for 572629A
TRF No. IEC60884_2_3C
63 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 58 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 572629A
572249A
TRF No. IEC60884_2_3C
64 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 59 of 94 Report No. ARLI-ESH-P22071876
572249A
Cover plate for 572249A
TRF No. IEC60884_2_3C
65 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 60 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 572249A
678139A
TRF No. IEC60884_2_3C
66 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 61 of 94 Report No. ARLI-ESH-P22071876
678139A
Cover plate for 678139A
TRF No. IEC60884_2_3C
67 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 62 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 678139A
730073A
TRF No. IEC60884_2_3C
68 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 63 of 94 Report No. ARLI-ESH-P22071876
730073A
832073A
TRF No. IEC60884_2_3C
69 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 64 of 94 Report No. ARLI-ESH-P22071876
832073A
Cover plate for 832073A
TRF No. IEC60884_2_3C
70 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 65 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 832073A
832473A
TRF No. IEC60884_2_3C
71 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 66 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 832473A
832273A
TRF No. IEC60884_2_3C
72 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 67 of 94 Report No. ARLI-ESH-P22071876
Cover plate for 832273A
Cover plate for 832273A
TRF No. IEC60884_2_3C
73 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 68 of 94 Report No. ARLI-ESH-P22071876
833073A
833073A
TRF No. IEC60884_2_3C
74 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 69 of 94 Report No. ARLI-ESH-P22071876
833073A
833473A
TRF No. IEC60884_2_3C
75 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 70 of 94 Report No. ARLI-ESH-P22071876
833273A
738145A
TRF No. IEC60884_2_3C
76 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 71 of 94 Report No. ARLI-ESH-P22071876
738145A
738145A
TRF No. IEC60884_2_3C
77 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 72 of 94 Report No. ARLI-ESH-P22071876
617666A
617666A
TRF No. IEC60884_2_3C
78 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 73 of 94 Report No. ARLI-ESH-P22071876
617666A
617666A
TRF No. IEC60884_2_3C
79 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 74 of 94 Report No. ARLI-ESH-P22071876
617766A
617766A
TRF No. IEC60884_2_3C
80 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 75 of 94 Report No. ARLI-ESH-P22071876
617866A
281130AMW
TRF No. IEC60884_2_3C
81 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 76 of 94 Report No. ARLI-ESH-P22071876
281130AMW
281130AMW
TRF No. IEC60884_2_3C
82 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 77 of 94 Report No. ARLI-ESH-P22071876
281130AMB
281130AMB
TRF No. IEC60884_2_3C
83 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 78 of 94 Report No. ARLI-ESH-P22071876
281130ADS
281130ADS
TRF No. IEC60884_2_3C
84 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 79 of 94 Report No. ARLI-ESH-P22071876
281130ACH
281130ACH
TRF No. IEC60884_2_3C
85 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 80 of 94 Report No. ARLI-ESH-P22071876
281130ADB
281130ADB
TRF No. IEC60884_2_3C
86 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 81 of 94 Report No. ARLI-ESH-P22071876
281130ABA
281130ABA
TRF No. IEC60884_2_3C
87 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 82 of 94 Report No. ARLI-ESH-P22071876
281130ABA
281130ABA
TRF No. IEC60884_2_3C
88 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 83 of 94 Report No. ARLI-ESH-P22071876
281130ABA
281130ABB
TRF No. IEC60884_2_3C
89 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 84 of 94 Report No. ARLI-ESH-P22071876
281130ABB
282483A
TRF No. IEC60884_2_3C
90 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 85 of 94 Report No. ARLI-ESH-P22071876
TRF No. IEC60884_2_3C
91 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 86 of 94 Report No. ARLI-ESH-P22071876
282483A
282483A
TRF No. IEC60884_2_3C
92 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 87 of 94 Report No. ARLI-ESH-P22071876
282483A
282483A-C
TRF No. IEC60884_2_3C
93 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 88 of 94 Report No. ARLI-ESH-P22071876
282483A-C
282483A-C1
TRF No. IEC60884_2_3C
94 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 89 of 94 Report No. ARLI-ESH-P22071876
282483A-C1
282483A-C2
TRF No. IEC60884_2_3C
95 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 90 of 94 Report No. ARLI-ESH-P22071876
282483A-C2
282483A-C3
TRF No. IEC60884_2_3C
96 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 91 of 94 Report No. ARLI-ESH-P22071876
282483A-C3
Main parts
TRF No. IEC60884_2_3C
97 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 92 of 94 Report No. ARLI-ESH-P22071876
Main parts
Main parts
TRF No. IEC60884_2_3C
98 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 93 of 94 Report No. ARLI-ESH-P22071876
Main parts
Main parts
TRF No. IEC60884_2_3C
99 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 94 of 94 Report No. ARLI-ESH-P22071876
Main parts
Main parts
TRF No. IEC60884_2_3C
100 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Test Report issued under the responsibility of:
TEST REPORT
IEC/EN 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number. .............................. : ARLI-ESH-P22071902
Date of issue ................................... : 2022-11-24
Total number of pages................... : 96
Name of Testing Laboratory LCIE CHINA COMPANY LIMITED
preparing the Report...................... :
Building 4, No. 518, Xin Zhuan Road, CaoHejing Songjiang High-
Tech Park, Shanghai P.R.C (201612)
........................... : Legrand Intelligent Electrical (Huizhou) Co., Ltd.
Address ........................................... : Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK Hi-tech Industrial
Development Zone, Huizhou, Guangdong, CHINA
Test specification:
Standard.......................................... : IEC 62368-1:2018 EN IEC 62368-1:2020+A11:2020
Test procedure ............................... : CE-LVD
Non-standard test method ............ : N/A
Test Report Form No. .................... : TEST REPORT IEC/EN 62368-1 VER 1.5
Test Report Form(s) Originator .... : LCIE CHINA
This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at
http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this
report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings
solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the
lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by
you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests.
Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You
have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty;
provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed
time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.
Test item description ....................... : USB MODULE
Trade Mark ........................................ :
Manufacturer/Address ..................... : Same as Applicant
Model/Type reference ...................... : B005399AA
Ratings .............................................. : I/P: 100-250V~, 50/60Hz, 0.5A
O/P: 5.0V 3.0A, 9.0V 2.0A, 12.0V 1.5A, 18.0W Max
Summer XIA
Tested by (name, function, signature) ........:
Project Engineer
Tom ZHANG
Approved by (name, function, signature)...:
Project Manager
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
101 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 2 of 96 Report No. ARLI-ESH-P22071902
List of Attachments (including a total number of pages in each attachment):
Attachment 1: List of Europe National Differences(58-77 pages)
Attachment 2: USB output test according to IEC 62368-3: 2017 and EN IEC 62368-3: 2020 (78-87 pages)
Attachment 3: Picture of EUT(88-96 pages)
Summary of testing:
The sample(s) tested complies with the requirements of IEC 62368-1: 2018, EN IEC 62368-1: 2020 + A11:
2020, IEC 62368-3: 2017 and EN IEC 62368-3: 2020.
Unless otherwise specified, all related tests were performed at around 25°C ambient temperatures in an
open bench.
The test result in this report applied the data from worst condition otherwise not specified.
The maximum operating temperature is defined as +35°C.
Tests performed (name of test and test clause): Testing location:
All clause. Test of standard of IEC 62368-1: 2018 LCIE CHINA COMPANY LIMITED.
Building 4, No. 518, Xin Zhuan Road, CaoHejing
Songjiang High-Tech Park, Shanghai P.R.C
(201612)
Summary of compliance with National Differences (List of countries addressed):
EU GROUP Differences
The product fulfils the requirements of IEC 62368-1: 2018, EN IEC 62368-1: 2020 + A11: 2020,
IEC 62368-3: 2017 and EN IEC 62368-3: 2020.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
102 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 3 of 96 Report No. ARLI-ESH-P22071902
Copy of marking plate:
Built-in equipment, shall be considered in the ending product.
Note:
The instruction sheet and marking should be translated to the language where the product will be sell.
The height of WEEE marking shall be at least 7 mm.
The CE height of other symbol shall be at least 5 mm.
For EUROPEAN market the batch number, name and address of EUROPEAN importer also should list in
the marking plate.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
103 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 4 of 96 Report No. ARLI-ESH-P22071902
Test item particulars:
Product group .....................................................: end product built-in component
Classification of use by ...................................... : Ordinary person Children likely present
Instructed person
Skilled person
Supply connection ............................................... : AC mains DC mains
not mains connected:
ES1 ES2 ES3
Supply tolerance ................................................. : +10%/-10%
+20%/-15%
+ %/ - %
None
Supply connection type .................................. : pluggable equipment type A -
non-detachable supply cord
appliance coupler
direct plug-in
pluggable equipment type B -
non-detachable supply cord
appliance coupler
permanent connection
mating connector
other: Determined by the end product
Considered current rating of protective 16 A;
device ................................................................. : Location: building equipment
N/A
Equipment mobility .......................................... : movable hand-held transportable
direct plug-in stationary for building-in
wall/ceiling-mounted SRME/rack-mounted
other:
Overvoltage category (OVC) ........................... : OVC I OVC II OVC III
OVC IV other:
Class of equipment ......................................... : Class I Class II Class III
Not classified
Special installation location ........................... : N/A restricted access area
outdoor location
Pollution degree (PD) ...................................... : PD 1 PD 2 PD 3
specified Tma........................... : 35°C Outdoor: minimum °C
IP protection class ........................................... : IPX0 IP___
Power systems ................................................. : TN TT IT - V L-L
not AC mains
Altitude during operation (m) ......................... : 2000 m or less m
Altitude of test laboratory (m) ........................ : 2000 m or less <50 m
Mass of equipment (kg) .................................. : Built-in equipment, shall be considered in the ending
product.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
104 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 5 of 96 Report No. ARLI-ESH-P22071902
Possible test case verdicts:
- test case does not apply to the test object .... : N/A
- test object does meet the requirement ........... : P (Pass)
- test object does not meet the requirement .... : F (Fail)
- test object does not demand : P (Not demanded)
Testing:
Date of receipt of test item ................................. : July 29, 2022
Date (s) of performance of tests ........................: July 30, 2022 to September 30, 2022
General remarks:
(See Enclosure #) refers to additional information appended to the report.
(See appended table) refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a
Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ................................................ :
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) ................. : Legrand Intelligent Electrical (Huizhou) Co., Ltd.
Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK Hi-
tech Industrial Development Zone, Huizhou,
Guangdong, CHINA
General product information and other remarks:
-The manufacturer specified maximum ambient temperature is 35 C.
- USB board of the USB model name: B005399AA. For final product.
- The USB module can be used in ending socket.
- All models use the same USB module, all tested were performed on power board equipped with USB
board: B005399AA.
-Each end product model is only the model name difference, used to distinguish different product color
and appearance, see following table for details:
Color of
Model Product description Range
enclosure
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
678139A SWITCHED WHITE
18W PD WHITE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
730073A SWITCHED WHITE
18W PD WHITE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
833073A SWITCHED BSS
18W PD BSS
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
833273A SWITCHED PSS
18W PD PSS
833473A 1G BS 13A SP SWITCHED SOCKET + USB TYPE C SWITCHED GOLD
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
105 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 6 of 96 Report No. ARLI-ESH-P22071902
18W PD GOLD
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
832073A SWITCHED BSS
18W PD BSS
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
832273A SWITCHED PSS
18W PD PSS
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
832473A SWITCHED GOLD
18W PD GOLD
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
738145A SWITCHED WHITE
18W PD WHITE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
617666A SWITCHED WHITE
18W PD WHITE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C PD
617766A SWITCHED
18W PD ANTHRACITE ANTHRACITE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
617866A SWITCHED IVORY
18W PD IVORY
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572129A SWITCHED WHITE
18W PD WHITE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572229A SWITCHED CHAMPAGNE
18W PD CHAMPAGNE
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572249A SWITCHED SOFT ALU
18W PD SOFT ALU
1G BS 13A SP SWITCHED SOCKET + USB TYPE C
572629A SWITCHED MAGNESIUM
18W PD MAGNESIUM
WHITE 1G BS 13A SWITCHED SOCKET + USB
282483A SWITCHED WHITE
TYPE C 18W PD
282483A- MATT BLACK 1G BS 13A SWITCHED SOCKET +
SWITCHED MATT BLACK
C USB TYPE C 18W PD
282483A- ROSE GOLD 1G BS 13A SWITCHED SOCKET + USB
SWITCHED ROSE GOLD
C1 TYPE C 18W PD
282483A- CHAMPAGNE 1G BS 13A SWITCHED SOCKET +
SWITCHED CHAMPAGNE
C2 USB TYPE C 18W PD
282483A- DARK SILVER 1G BS 13A SWITCHED SOCKET +
SWITCHED DRAK SILVER
C3 USB TYPE C 18W PD
281130AB 1G BS 13A SINGLE POLE SWITCHED SOCKET + BRUSHED
SWITCHED
A USB TYPE C 18W PD BRUSHED ALUMINIUM ALUMINIUM
281130AB 1G BS 13A SINGLE POLE SWITCHED SOCKET + BRUSHED
SWITCHED
B USB TYPE C 18W PD BRUSHED BLACK BLACK
281130A 1G BS 13A SINGLE POLE SWITCHED SOCKET +
SWITCHED CHAMPAGNE
CH USB TYPE C 18W PD CHAMPAGNE
281130A 1G BS 13A SINGLE POLE SWITCHED SOCKET +
SWITCHED DARK BRONZE
DB USB TYPE C 18W PD DARK BRONZE
281130A 1G BS 13A SINGLE POLE SWITCHED SOCKET +
SWITCHED DARK SILVER
DS USB TYPE C 18W PD DARK SILVER
281130A 1G BS 13A SINGLE POLE SWITCHED SOCKET +
SWITCHED MATT BLACK
MB USB TYPE C 18W PD MATT BLACK
281130A 1G BS 13A SINGLE POLE SWITCHED SOCKET +
SWITCHED MATT WHITE
MW USB TYPE C 18W PD MATT WHITE
1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
678132A WHITE
18W PD WHITE ED
1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
617665A WHITE
18W PD WHITE ED
1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
617765A ANTHRACITE
18W PD ANTHRACITE ED
1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
617865A IVORY
18W PD IVORY ED
1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
572127A WHITE
18W PD WHITE ED
572228A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH CHAMPAGNE
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
106 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 7 of 96 Report No. ARLI-ESH-P22071902
18W PD CHAMPAGNE ED
1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
572258A SOFT ALU
18W PD SOFT ALU ED
572627A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
MAGNESIUM
18W PD MAGNESIUM ED
WHITE 1G BS 13A UNSWITCHED SOCKET + USB UNSWITCH
282482A WHITE
TYPE C 18W PD ED
282482A- MATT BLACK 1G BS 13A UNSWITCHED SOCKET + UNSWITCH
MATT
C USB TYPE C 18W PD ED
282482A- ROSE GOLD 1G BS 13A UNSWITCHED SOCKET + UNSWITCH
ROSE GOLD
C1 USB TYPE C 18W PD ED
282482A- CHAMPAGNE 1G BS 13A UNSWITCHED SOCKET + UNSWITCH
CHAMPAGNE
C2 USB TYPE C 18W PD ED
282482A- DARK SILVER 1G BS 13A UNSWITCHED SOCKET + UNSWITCH
DARK SILVER
C3 USB TYPE C 18W PD ED
281131AB 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH BRUSHED
A 18W PD BRUSHED ALUMINIUM ED ALUMINIUM
281131AB 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH BRUSHED
B 18W PD BRUSHED BLACK ED BLACK
281131A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
CHAMPAGNE
CH 18W PD CHAMPAGNE ED
281131A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
DRAK BRONZE
DB 18W PD DARK BRONZE ED
281131A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
DRAK SILVER
DS 18W PD DARK SILVER ED
281131A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
MATT BLACK
MB 18W PD MATT BLACK ED
281131A 1G BS 13A UNSWITCHED SOCKET + USB TYPE C UNSWITCH
MATT WHITE
MW 18W PD MATT WHITE ED
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
107 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 8 of 96 Report No. ARLI-ESH-P22071902
OVERVIEW OF ENERGY SOURCES AND SAFEGUARDS
Clause Possible Hazard
5 Electrically-caused injury
Class and Energy Source Body Part Safeguards
(e.g. ES3: Primary circuit) (e.g. Ordinary) B S R
ES1:Intenal circuit after output Ordinary N/A N/A N/A
of transformer
ES3:Internal circuit of primary Ordinary N/A N/A Enclosure
power supply request,
Evaluate in
the end-
product
6 Electrically-caused fire
Class and Energy Source Material part Safeguards
(e.g. PS2: 100 Watt circuit) (e.g. Printed board) B 1st S 2nd S
PS3 circuit Internal circuit of primary No Suitable N/A
power supply inside ignition components
enlcosure temperature and material
used;
Fire
enclosure
PS1 circuit USB output N/A N/A N/A
7 Injury caused by hazardous substances
Class and Energy Source Body Part Safeguards
(e.g. Ozone) (e.g., Skilled) B S R
N/A N/A N/A N/A N/A
8 Mechanically-caused injury
Class and Energy Source Body Part Safeguards
(e.g. MS3: Plastic fan blades) (e.g. Ordinary) B S R
MS1: Sharp edges and corners Ordinary N/A N/A N/A
MS1: Equipment mass Ordinary N/A N/A N/A
9 Thermal burn
Class and Energy Source Body Part Safeguards
(e.g. TS1: Keyboard caps) (e.g., Ordinary) B S R
TS1: External surfaces that Ordinary N/A N/A N/A
touch occasionally (evaluate in
the end product )
10 Radiation
Class and Energy Source Body Part Safeguards
(e.g. RS1: PMP sound output) (e.g., Ordinary) B S R
N/A N/A N/A N/A N/A
Supplementary Information:
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
108 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 9 of 96 Report No. ARLI-ESH-P22071902
Reinforced Safeguard
ENERGY SOURCE DIAGRAM
Optional. Manufacturers are to provide the energy sources diagram identify declared energy sources and
identifying the demarcations are between power sources. Recommend diagram be provided included in
power supply and multipart systems.
Insert diagram below. Example diagram designs are; Block diagrams; image(s) with layered data; mechanical
drawings
--
ES: ES1, ES3 PS: PS2, PS3 MS: MS1 TS: TS1 RS
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
109 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 10 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4 GENERAL REQUIREMENTS N/A
4.1.1 Acceptance of materials, components and
(See appended table 4.1.2) P
subassemblies
4.1.2 Use of components (See appended table 4.1.2) P
4.1.3 Equipment design and construction P
4.1.4 Specified ambient temperature for outdoor use (oC) Not for outdoor use.
N/A
.................................................................................... :
4.1.5 Constructions and components not specifically
P
covered
4.1.8 Liquids and liquid filled components (LFC) (See G.15) N/A
4.1.15 Markings and instructions Built-in equipment N/A
4.4.3 Safeguard robustness Built-in equipment N/A
4.4.3.1 General Built-in equipment N/A
4.4.3.2 Steady force tests (See Clause T.3, T.4, T.5) P
4.4.3.3 Drop tests (See Annex T.7) N/A
4.4.3.4 Impact tests (See Clause T.6) N/A
4.4.3.5 Internal accessible safeguard tests (See Clause T.3) N/A
4.4.3.6 Glass impact tests (See Clause T.9, Annex U) N/A
4.4.3.7 Glass fixation tests N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests (See Annex T.8) P
4.4.3.9 Air comprising a safeguard P
4.4.3.10 Accessibility, glass, safeguard effectiveness N/A
4.4.4 Displacement of a safeguard by an insulating liquid N/A
4.4.5 Safety interlocks (See Annex K) N/A
4.5 Explosion P
4.5.1 General P
4.5.2 No explosion during normal/abnormal operating (See Clause B.2, B.3)
P
condition
No harm by explosion during single fault conditions (See Clause B.4) P
4.6 Fixing of conductors P
Fix conductors not to defeat a safeguard P
Compliance is checked by test .............................. : (See Clause T.2) P
4.7 Equipment for direct insertion into mains socket outlets N/A
4.7.2 Mains plug part complies with relevant standard .. : Evaluated in end product N/A
4.7.3 Torque (Nm) .......................................................... : Built-in USB module only N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
110 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 11 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4.8 Equipment containing coin/button cell batteries N/A
4.8.1 General No such battery. N/A
4.8.2 Instructional safeguard .......................................... : See above N/A
4.8.3 Battery compartment door/cover construction N/A
Open torque test N/A
4.8.4.2 Stress relief test (See Annex T.8) N/A
4.8.4.3 Battery replacement test N/A
4.8.4.4 Drop test N/A
4.8.4.5 Impact test N/A
4.8.4.6 Crush test N/A
4.8.5 Compliance N/A
30N force test with test probe N/A
20N force test with test hook N/A
4.9 Likelihood of fire or shock due to entry of conductive object N/A
4.10 Component requirements N/A
4.10.1 Disconnect Device (See Annex L) N/A
4.10.2 Switches and relays (See Annex G) N/A
5 ELECTRICALLY-CAUSED INJURY P
5.2 Classification and limits of electrical energy sources P
5.2.2 ES1, ES2 and ES3 limits P
5.2.2.2 Steady-state voltage and current limits .................... : See table OVERVIEW OF
ENERGY SOURCES AND P
SAFEGUARDS
5.2.2.3 Capacitance limits ..................................................... : N/A
5.2.2.4 Single pulse limits ..................................................... : N/A
5.2.2.5 Limits for repetitive pulses ........................................ : N/A
5.2.2.6 Ringing signals N/A
5.2.2.7 Audio signals N/A
5.3 Protection against electrical energy sources P
5.3.1 General Requirements for accessible parts to Built-in equipment
P
ordinary, instructed and skilled persons
5.3.1 a) Accessible ES1/ES2 derived from ES2/ES3 circuits Built-in equipment P
5.3.1 b) Skilled persons not unintentional contact ES3 bare
N/A
conductors
5.3.2.1 Accessibility to electrical energy sources and
N/A
safeguards
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
111 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 12 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Accessibility to outdoor equipment bare parts N/A
5.3.2.2 Contact requirements P
Test with test probe from Annex V Figure V.1 and V.2. -
5.3.2.2 a) Air gap electric strength test potential (V) ............. : (See appended table 5.4.9) N/A
5.3.2.2 b) Air gap distance (mm) ........................................... : N/A
5.3.2.3 Compliance N/A
5.3.2.4 Terminals for connecting stripped wire N/A
5.4 Insulation materials and requirements P
5.4.1.2 Properties of insulating material P
5.4.1.3 Material is non-hygroscopic P
5.4.1.4 Maximum operating temperature for insulating (See appended table 5.4.1.4)
P
materials .................................................................... :
5.4.1.5 Pollution degrees ...................................................... : Pollution degree 2 P
5.4.1.5.2 Test for pollution degree 1 environment and for an
N/A
insulating compound
5.4.1.5.3 Thermal cycling test N/A
5.4.1.6 Insulation in transformers with varying dimensions N/A
5.4.1.7 Insulation in circuits generating starting pulses N/A
5.4.1.8 Determination of working voltage ............................. : (See appended table 5.4.1.8) P
5.4.1.9 Insulating surfaces P
5.4.1.10 Thermoplastic parts on which conductive metallic
P
parts are directly mounted
5.4.1.10.2 Vicat test .................................................................... : N/A
5.4.1.10.3 Ball pressure test ...................................................... : (See appended table
N/A
5.4.1.10.3)
5.4.2 Clearances P
5.4.2.1 General requirements P
Clearances in circuits connected to AC Mains, (See Annex X)
N/A
Alternative method
5.4.2.2 Procedure 1 for determining clearance P
Temporary overvoltage ............................................ : 4000V
5.4.2.3 Procedure 2 for determining clearance P
5.4.2.3.2.2 a.c. mains transient voltage ...................................... : Consider OVC III
5.4.2.3.2.3 d.c. mains transient voltage ..................................... :
5.4.2.3.2.4 External circuit transient voltage............................... : No such external circuit
5.4.2.3.2.5 Transient voltage determined by measurement ...... : See above
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
112 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 13 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.2.4 Determining the adequacy of a clearance using an
N/A
electric strength test ................................................. : (See appended table 5.4.2)
5.4.2.5 Multiplication factors for clearances and test voltages 1.0 was chosen for altitude up
P
................................................................................... : to 2000m.
5.4.2.6 Clearance measurement .......................................... : (See appended table 5.4.2) P
5.4.3 Creepage distances P
5.4.3.1 General P
5.4.3.3 Material group ........................................................... : IIIb
5.4.3.4 Creepage distances measurement .......................... : (See appended table 5.4.3) P
5.4.4 Solid insulation P
5.4.4.1 General requirements P
5.4.4.2 Minimum distance through insulation ...................... : (See appended table 5.4.4.2) P
5.4.4.3 Insulating compound forming solid insulation N/A
5.4.4.4 Solid insulation in semiconductor devices N/A
5.4.4.5 Insulating compound forming cemented joints N/A
5.4.4.6 Thin sheet material P
5.4.4.6.1 General requirements P
5.4.4.6.2 Separable thin sheet material P
Number of layers (pcs) ......................................... : At least 2 layer used. P
5.4.4.6.3 Non-separable thin sheet material N/A
Number of layers (pcs) ......................................... : No such thin sheet material
N/A
used
5.4.4.6.4 Standard test procedure for non-separable thin (See appended table 5.4.9)
N/A
sheet material ........................................................ :
5.4.4.6.5 Mandrel test N/A
5.4.4.7 Solid insulation in wound components P
5.4.4.9 Solid insulation at frequencies >30 kHz, EP, KR, d, (See appended Table 5.4.4.9)
N/A
VPW (V) ................................................................. :
Alternative by electric strength test, tested voltage (See appended Tables 5.4.4.9
N/A
(V), KR ................................................................... : and 5.4.9)
5.4.5 Antenna terminal insulation No such antenna N/A
5.4.5.1 General N/A
5.4.5.2 Voltage surge test N/A
5.4.5.3 Insulation resistance (M ) ..................................... : N/A
Electric strength test ................................................. : (See appended table 5.4.9) N/A
5.4.6 Insulation of internal wire as part of supplementary
N/A
safeguard
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
113 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 14 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.7 Tests for semiconductor components and for
N/A
cemented joints
5.4.8 Humidity conditioning P
Relative humidity (%), temperature (°C), duration
(h) .......................................................................... : 93%, 40°C, 120h.
5.4.9 Electric strength test P
5.4.9.1 Test procedure for type test of solid insulation ....... : (See appended table 5.4.9) P
5.4.9.2 Test procedure for routine test N/A
5.4.10 Safeguards against transient voltages from external
N/A
circuits
5.4.10.1 Parts and circuits separated from external circuits N/A
5.4.10.2 Test methods N/A
5.4.10.2.1 General N/A
5.4.10.2.2 Impulse test ........................................................... : (See appended table 5.4.9) N/A
5.4.10.2.3 Steady-state test .................................................... : (See appended table 5.4.9) N/A
5.4.10.3 Verification for insulation breakdown for impulse
N/A
test ......................................................................... :
5.4.11 Separation between external circuits and earth N/A
5.4.11.1 Exceptions to separation between external circuits
N/A
and earth
5.4.11.2 Requirements N/A
SPDs bridge separation between external circuit
N/A
and earth
Rated operating voltage Uop (V) ............................. :
Nominal voltage Upeak (V) ....................................... :
Max increase due to variation Usp ........................ :
Max increase due to ageing Usa ......................... :
5.4.11.3 Test method and compliance ................................ : (See appended table 5.4.9) N/A
5.4.12 Insulating liquid N/A
5.4.12.1 General requirements N/A
5.4.12.2 Electric strength of an insulating liquid .................. : (See appended table 5.4.9) N/A
5.4.12.3 Compatibility of an insulating liquid ....................... : (See appended table 5.4.9) N/A
5.4.12.4 Container for insulating liquid ................................ : N/A
5.5 Components as safeguards P
5.5.1 General P
5.5.2 Capacitors and RC units P
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
114 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 15 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.5.2.1 General requirement Y-Cap. are IEC 60384-14 P
approval components and
complied with Annex G.11.
5.5.2.2 Safeguards against capacitor discharge after N/A
disconnection of a connector ................................. :
5.5.3 Transformers See clause G.5.3 P
5.5.4 Optocouplers See clause G.12 N/A
5.5.5 Relays See clause G.2 N/A
5.5.6 Resistors No such resistors N/A
5.5.7 SPDs N/A
5.5.8 Insulation between the mains and an external N/A
circuit consisting of a coaxial cable ....................... : No such external circuit
5.5.9 Safeguards for socket-outlets in outdoor equipment N/A
RCD rated residual operating current (mA) ........... : No such device
5.6 Protective conductor N/A
5.6.2 Requirement for protective conductors N/A
5.6.2.1 General requirements N/A
5.6.2.2 Colour of insulation N/A
5.6.3 Requirement for protective earthing conductors N/A
Protective earthing conductor size (mm2) .............. :
Protective earthing conductor serving as a
N/A
reinforced safeguard
Protective earthing conductor serving as a double
N/A
safeguard
5.6.4 Requirements for protective bonding conductors N/A
5.6.4.1 Protective bonding conductors N/A
Protective bonding conductor size (mm2). .............. :
5.6.4.2 Protective current rating (A) .................................... : N/A
5.6.5 Terminals for protective conductors N/A
5.6.5.1 Terminal size for connecting protective earthing
N/A
conductors (mm) .................................................... :
Terminal size for connecting protective bonding N/A
N/A
conductors (mm) ....................................................... :
5.6.5.2 Corrosion N/A
5.6.6 Resistance of the protective bonding system N/A
5.6.6.1 Requirements N/A
5.6.6.2 Test Method ........................................................... : (See appended table 5.6.6) N/A
5.6.6.3 Resistance ( ) or voltage drop .............................. : (See appended table 5.6.6) N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
115 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 16 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.6.7 Reliable connection of a protective earthing
N/A
conductor
5.6.8 Functional earthing N/A
Conductor size (mm2)............................................. : N/A
Class II with functional earthing marking .............. : N/A
Appliance inlet cl & cr (mm) ................................... : N/A
5.7 Prospective touch voltage, touch current and protective conductor current P
5.7.2 Measuring devices and networks P
5.7.2.1 Measurement of touch current P
5.7.2.2 Measurement of voltage N/A
5.7.3 Equipment set-up, supply connections and earth
P
connections
5.7.4 Unearthed accessible parts ................................... : (See appended table 5.7.4) P
5.7.5 Earthed accessible conductive parts ..................... : (See appended table 5.7.5) N/A
5.7.6 Requirements when touch current exceeds ES2 Not exceeds ES2 limit
N/A
limits
Protective conductor current (mA) ......................... : No such construction N/A
Instructional Safeguard .......................................... : See above N/A
5.7.7 Prospective touch voltage and touch current
N/A
associated with external circuits
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current
N/A
associated with paired conductor cables
5.7.8 Summation of touch currents from external circuits No such external circuit N/A
a) Equipment connected to earthed external
N/A
circuits, current (mA) ............................................. : See above
b) Equipment connected to unearthed external
N/A
circuits, current (mA) ............................................. : See above
5.8 Backfeed safeguard in battery backed up supplies N/A
Mains terminal ES ..................................................... : No battery used N/A
Air gap (mm).............................................................. : See above N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
116 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 17 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6 ELECTRICALLY- CAUSED FIRE P
6.2 Classification of PS and PIS P
6.2.2 Power source circuit classifications .......................... : See table OVERVIEW OF
ENERGY SOURCES AND P
SAFEGUARDS.
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................................................ : Considered arcing PIS existed
P
in PS3 circuit.
6.2.3.2 Resistive PIS ............................................................ : Considered resistive PIS
P
existed in PS3 circuit.
6.3 Safeguards against fire under normal operating and abnormal operating
P
conditions
6.3.1 No ignition and attainable temperature value less (See appended table B.1.5 and
than 90 % defined by ISO 871 or less than 300 C B.3) P
for unknown materials ........................................... :
Combustible materials outside fire enclosure .......... : Combustible material inside
P
the fire enclosure.
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard method P
6.4.2 Reduction of the likelihood of ignition under single
N/A
fault conditions in PS1 circuits
6.4.3 Reduction of the likelihood of ignition under single
N/A
fault conditions in PS2 and PS3 circuits
6.4.3.1 Supplementary safeguards N/A
6.4.3.2 Single Fault Conditions .......................................... : (See appended table B.4) N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits N/A
6.4.5 Control of fire spread in PS2 circuits P
6.4.5.2 Supplementary safeguards (See appended tables 4.1.2
P
and Annex G)
6.4.6 Control of fire spread in PS3 circuits Component mounted on V-0 P
PCB, all in fire enclosure.
6.4.7 Separation of combustible materials from a PIS N/A
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a fire barrier N/A
6.4.8 Fire enclosures and fire barriers P
6.4.8.2 Fire enclosure and fire barrier material properties P
6.4.8.2.1 Requirements for a fire barrier N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
117 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 18 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.4.8.2.2 Requirements for a fire enclosure V-0 fire enclosure, and less
P
than 4000W
6.4.8.3 Constructional requirements for a fire enclosure
P
and a fire barrier
6.4.8.3.1 Fire enclosure and fire barrier openings No openings on fire enclosure. P
6.4.8.3.2 Fire barrier dimensions N/A
6.4.8.3.3 Top openings and properties N/A
Openings dimensions (mm)................................... : No such opening N/A
6.4.8.3.4 Bottom openings and properties N/A
Openings dimensions (mm)................................... : No such opening N/A
Flammability tests for the bottom of a fire enclosure (See Clause S.3) N/A
Instructional Safeguard ............................................. : See above N/A
6.4.8.3.5 Side openings and properties N/A
Openings dimensions (mm)................................... : N/A
6.4.8.3.6 Integrity of a fire enclosure, condition met: a), b) or
N/A
c) ............................................................................ :
6.4.8.4 Separation of a PIS from a fire enclosure and a fire The enclosure made of V-0
P
barrier distance (mm) or flammability rating .......... : class material in end products.
6.4.9 Flammability of insulating liquid............................... : No such liquid N/A
6.5 Internal and external wiring P
6.5.1 General requirements Approved VW-1 wire used. P
6.5.2 Requirements for interconnection to building wiring
Not connected to building wire N/A
............................................................................... :
6.5.3 Internal wiring size (mm 2) for socket-outlets.......... : P
6.6 Safeguards against fire due to the connection to additional equipment P
7 INJURY CAUSED BY HAZARDOUS SUBSTANCES N/A
7.2 Reduction of exposure to hazardous substances N/A
7.3 Ozone exposure N/A
7.4 Use of personal safeguards or personal protective equipment (PPE) N/A
Personal safeguards and instructions ................... :
7.5 Use of instructional safeguards and instructions N/A
Instructional safeguard (ISO 7010)........................ :
7.6 Batteries and their protection circuits N/A
8 MECHANICALLY-CAUSED INJURY P
8.2 Mechanical energy source classifications P
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
118 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 19 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8.3 Safeguards against mechanical energy sources P
8.4 Safeguards against parts with sharp edges and corners P
8.4.1 Safeguards No safeguard required for MS1 N/A
edged and corners.
Instructional Safeguard ............................................. : See above. N/A
8.4.2 Sharp edges or corners P
8.5 Safeguards against moving parts N/A
8.5.1 Fingers, jewellery, clothing, hair, etc., contact with No moving parts
N/A
MS2 or MS3 parts
MS2 or MS3 part required to be accessible for the
N/A
function of the equipment
Moving MS3 parts only accessible to skilled person N/A
8.5.2 Instructional safeguard.............................................. : N/A
8.5.4 Special categories of equipment containing moving
N/A
parts
8.5.4.1 General N/A
8.5.4.2 Equipment containing work cells with MS3 parts N/A
8.5.4.2.1 Protection of persons in the work cell N/A
8.5.4.2.2 Access protection override N/A
8.5.4.2.2.1 Override system N/A
8.5.4.2.2.2 Visual indicator N/A
8.5.4.2.3 Emergency stop system N/A
Maximum stopping distance from the point of
N/A
activation (m) ............................................................. :
Space between end point and nearest fixed
N/A
mechanical part (mm) ............................................... :
8.5.4.2.4 Endurance requirements N/A
Mechanical system subjected to 100 000 cycles of
N/A
operation
- Mechanical function check and visual inspection N/A
- Cable assembly ...................................................... : N/A
8.5.4.3 Equipment having electromechanical device for
N/A
destruction of media
8.5.4.3.1 Equipment safeguards N/A
8.5.4.3.2 Instructional safeguards against moving parts ........ : N/A
8.5.4.3.3 Disconnection from the supply N/A
8.5.4.3.4 Cut type and test force (N)........................................ : N/A
8.5.4.3.5 Compliance N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
119 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 20 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8.5.5 High pressure lamps N/A
Explosion test ............................................................ : N/A
8.5.5.3 Glass particles dimensions (mm) ............................. : N/A
8.6 Stability of equipment N/A
8.6.1 General Build-in equipment. N/A
Instructional safeguard.............................................. : N/A
8.6.2 Static stability N/A
8.6.2.2 Static stability test ..................................................... : N/A
8.6.2.3 Downward force test N/A
8.6.3 Relocation stability N/A
Wheels diameter (mm) ............................................. :
Tilt test N/A
8.6.4 Glass slide test N/A
8.6.5 Horizontal force test .................................................. : N/A
8.7 Equipment mounted to wall, ceiling or other structure N/A
8.7.1 Mount means type .................................................... : N/A
8.7.2 Test methods N/A
Test 1, additional downwards force (N) .................... : N/A
Test 2, number of attachment points and test force
N/A
(N) .............................................................................. : See above
Test 3 Nominal diameter (mm) and applied torque
N/A
(Nm)........................................................................... : See above
8.8 Handles strength N/A
8.8.1 General No such handle N/A
8.8.2 Handle strength test N/A
Number of handles .................................................... : See above
Force applied (N) ...................................................... : See above
8.9 Wheels or casters attachment requirements N/A
8.9.2 Pull test N/A
8.10 Carts, stands and similar carriers N/A
8.10.1 General N/A
8.10.2 Marking and instructions ........................................... : N/A
8.10.3 Cart, stand or carrier loading test N/A
Loading force applied (N) ......................................... : N/A
8.10.4 Cart, stand or carrier impact test N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
120 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 21 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8.10.5 Mechanical stability N/A
Force applied (N) ...................................................... :
8.10.6 Thermoplastic temperature stability N/A
8.11 Mounting means for slide-rail mounted equipment (SRME) N/A
8.11.1 General N/A
8.11.2 Requirements for slide rails N/A
Instructional Safeguard ............................................. : N/A
8.11.3 Mechanical strength test N/A
8.11.3.1 Downward force test, force (N) applied .................... : N/A
8.11.3.2 Lateral push force test N/A
8.11.3.3 Integrity of slide rail end stops N/A
8.11.4 Compliance N/A
8.12 Telescoping or rod antennas N/A
Button/ball diameter (mm) ........................................ :
9 THERMAL BURN INJURY P
9.2 Thermal energy source classifications P
9.3 Touch temperature limits P
9.3.1 Touch temperatures of accessible parts .................. : (See appended table) P
9.3.2 Test method and compliance P
9.4 Safeguards against thermal energy sources N/A
9.5 Requirements for safeguards N/A
9.5.1 Equipment safeguard N/A
9.5.2 Instructional safeguard.............................................. : N/A
9.6 Requirements for wireless power transmitters N/A
9.6.1 General N/A
9.6.2 Specification of the foreign objects N/A
9.6.3 Test method and compliance ................................... : (See appended table 9.6) N/A
10 RADIATION N/A
10.2 Radiation energy source classification N/A
10.2.1 General classification N/A
Lasers .................................................................... :
Lamps and lamp systems ...................................... :
Image projectors .................................................... :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
121 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 22 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
X-Ray ..................................................................... :
Personal music player ........................................... :
10.3 Safeguards against laser radiation N/A
The standard(s) equipment containing laser(s)
N/A
comply ....................................................................... : No such laser radiation
10.4 Safeguards against optical radiation from lamps and lamp systems (including
N/A
LED types)
10.4.1 General requirements N/A
Instructional safeguard provided for accessible
N/A
radiation level needs to exceed
Risk group marking and location .............................. : N/A
Information for safe operation and installation N/A
10.4.2 Requirements for enclosures N/A
UV radiation exposure .............................................. : (See Annex C) N/A
10.4.3 Instructional safeguard .......................................... : N/A
10.5 Safeguards against X-radiation N/A
10.5.1 Requirements N/A
Instructional safeguard for skilled persons ............ :
10.5.3 Maximum radiation (pA/kg).................................... : (See appended tables B.3 &
B.4)
10.6 Safeguards against acoustic energy sources N/A
10.6.1 General N/A
10.6.2 Classification N/A
Acoustic output LAeq,T, dB(A)..................................... : N/A
Unweighted RMS output voltage (mV) ..................... : N/A
Digital output signal (dBFS) ...................................... : N/A
10.6.3 Requirements for dose-based systems N/A
10.6.3.1 General requirements N/A
10.6.3.2 Dose-based warning and automatic decrease N/A
10.6.3.3 Exposure-based warning and requirements N/A
30 s integrated exposure level (MEL30) .................. : N/A
.................................. : N/A
10.6.4 Measurement methods N/A
10.6.5 Protection of persons N/A
Instructional safeguards ........................................ : N/A
10.6.6 Requirements for listening devices (headphones,
N/A
earphones, etc.)
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
122 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 23 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
10.6.6.1 Corded listening devices with analogue input N/A
Listening device input voltage (mV)....................... : N/A
10.6.6.2 Corded listening devices with digital input N/A
Max. acoustic output LAeq,T, dB(A) ............................ : N/A
10.6.6.3 Cordless listening devices N/A
Max. acoustic output LAeq,T, dB(A) ............................ : N/A
NORMAL OPERATING CONDITION TESTS, ABNORMAL OPERATING P
B
CONDITION TESTS AND SINGLE FAULT CONDITION TESTS
B.1 General P
B.1.5 Temperature measurement conditions (See appended table B.1.5) P
B.2 Normal operating conditions P
B.2.1 General requirements ............................................ : (See Test Item Particulars and P
appended test tables)
Audio Amplifiers and equipment with audio (See Annex E) N/A
amplifiers ............................................................... :
B.2.3 Supply voltage and tolerances P
B.2.5 Input test ................................................................ : (See appended table B.2.5) P
B.3 Simulated abnormal operating conditions P
B.3.1 General P
B.3.2 Covering of ventilation openings N/A
Instructional safeguard .......................................... : Not used on soft support N/A
B.3.3 DC mains polarity test N/A
B.3.4 Setting of voltage selector N/A
B.3.5 Maximum load at output terminals (See appended table B.3) P
B.3.6 Reverse battery polarity N/A
B.3.7 Audio amplifier abnormal operating conditions N/A
B.3.8 Safeguards functional during and after abnormal (See appended table B.3) P
operating conditions .............................................. :
B.4 Simulated single fault conditions P
B.4.1 General P
B.4.2 Temperature controlling device N/A
B.4.3 Blocked motor test N/A
B.4.4 Functional insulation P
B.4.4.1 Short circuit of clearances for functional insulation P
B.4.4.2 Short circuit of creepage distances for functional P
insulation
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
123 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 24 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.4.4.3 Short circuit of functional insulation on coated N/A
printed boards
B.4.5 Short-circuit and interruption of electrodes in tubes P
and semiconductors
B.4.6 Short circuit or disconnection of passive P
components
B.4.7 Continuous operation of components N/A
B.4.8 Compliance during and after single fault conditions (See appended table B.4) P
............................................................................... :
B.4.9 Battery charging and discharging under single fault (See Annex M) N/A
conditions
C UV RADIATION N/A
C.1 Protection of materials in equipment from UV radiation N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test N/A
C.2.1 Test apparatus ....................................................... : N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon-arc light-exposure test N/A
C.2.4 Xenon-arc light-exposure test N/A
D TEST GENERATORS N/A
D.1 Impulse test generators N/A
D.2 Antenna interface test generator N/A
D.3 Electronic pulse generator N/A
E TEST CONDITIONS FOR EQUIPMENT CONTAINING AUDIO AMPLIFIERS N/A
E.1 Electrical energy source classification for audio signals N/A
Maximum non-clipped output power (W) ............... :
.................................... :
Open-circuit output voltage (V) .............................. :
Instructional safeguard .......................................... :
E.2 Audio amplifier normal operating conditions N/A
Audio signal source type ....................................... :
Audio output power (W) ......................................... :
Audio output voltage (V) ........................................ :
.................................... :
Requirements for temperature measurement N/A
E.3 Audio amplifier abnormal operating conditions N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
124 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 25 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
F EQUIPMENT MARKINGS, INSTRUCTIONS, AND INSTRUCTIONAL N/A
SAFEGUARDS
F.1 General N/A
Language .............................................................. : For building-in product only,
To be considered in the end
product.
F.2 Letter symbols and graphical symbols N/A
F.2.1 Letter symbols according to IEC60027-1 N/A
F.2.2 Graphic symbols according to IEC, ISO or N/A
manufacturer specific
F.3 Equipment markings N/A
F.3.1 Equipment marking locations For building-in product only, N/A
To be considered in the end
product.
F.3.2 Equipment identification markings N/A
F.3.2.1 Manufacturer identification ................................... : For building-in product only, N/A
To be considered in the end
product.
F.3.2.2 Model identification ............................................... : For building-in product only, N/A
To be considered in the end
product.
F.3.3 Equipment rating markings N/A
F.3.3.1 Equipment with direct connection to mains N/A
F.3.3.2 Equipment without direct connection to mains N/A
F.3.3.3 Nature of the supply voltage .................................. : For building-in product only, N/A
To be considered in the end
product.
F.3.3.4 Rated voltage......................................................... : For building-in product only, N/A
To be considered in the end
product.
F.3.3.5 Rated frequency .................................................... : For building-in product only, N/A
To be considered in the end
product.
F.3.3.6 Rated current or rated power ................................. : For building-in product only, N/A
To be considered in the end
product.
F.3.3.7 Equipment with multiple supply connections N/A
F.3.4 Voltage setting device N/A
F.3.5 Terminals and operating devices N/A
F.3.5.1 Mains appliance outlet and socket-outlet markings For building-in product only, N/A
............................................................................... : To be considered in the end
product.
F.3.5.2 Switch position identification marking .................... : N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
125 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 26 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
F.3.5.3 Replacement fuse identification and rating markings N/A
............................................................................... :
Instructional safeguards for neutral fuse ............... : N/A
F.3.5.4 Replacement battery identification marking .......... : N/A
F.3.5.5 Neutral conductor terminal N/A
F.3.5.6 Terminal marking location N/A
F.3.6 Equipment markings related to equipment N/A
classification
F.3.6.1 Class I equipment N/A
F.3.6.1.1 Protective earthing conductor terminal .................. : N/A
F.3.6.1.2 Protective bonding conductor terminals ............... : N/A
F.3.6.2 Equipment class marking ...................................... : N/A
F.3.6.3 Functional earthing terminal marking .................... : N/A
F.3.7 Equipment IP rating marking ................................. : N/A
F.3.8 External power supply output marking .................. : N/A
F.3.9 Durability, legibility and permanence of marking N/A
F.3.10 Test for permanence of markings N/A
F.4 Instructions N/A
a)Information prior to installation and initial use N/A
b)Equipment for use in locations where children not N/A
likely to be present
c)Instructions for installation and interconnection N/A
d)Equipment intended for use only in restricted N/A
access area
e)Equipment intended to be fastened in place N/A
f)Instructions for audio equipment terminals N/A
g)Protective earthing used as a safeguard N/A
h)Protective conductor current exceeding ES2 limits N/A
i)Graphic symbols used on equipment N/A
j)Permanently connected equipment not provided N/A
with all-pole mains switch
k)Replaceable components or modules providing N/A
safeguard function
l)Equipment containing insulating liquid N/A
m)Installation instructions for outdoor equipment N/A
F.5 Instructional safeguards N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
126 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 27 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G COMPONENTS P
G.1 Switches N/A
G.1.1 General N/A
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.1.3 Test method and compliance N/A
G.2 Relays N/A
G.2.1 Requirements N/A
G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supplying power to N/A
other equipment
G.2.4 Test method and compliance N/A
G.3 Protective devices P
G.3.1 Thermal cut-offs N/A
Thermal cut-outs separately approved according to N/A
IEC 60730 with conditions indicated in a) & b)
Thermal cut-outs tested as part of the equipment as N/A
indicated in c)
G.3.1.2 Test method and compliance N/A
G.3.2 Thermal links N/A
G.3.2.1 a) Thermal links tested separately according to IEC N/A
60691 with specifics
b) Thermal links tested as part of the equipment N/A
G.3.2.2 Test method and compliance N/A
G.3.3 PTC thermistors N/A
G.3.4 Overcurrent protection devices P
G.3.5 Safeguards components not mentioned in G.3.1 to N/A
G.3.4
G.3.5.1 Non-resettable devices suitably rated and marking N/A
provided
G.3.5.2 Single faults conditions .......................................... : (See appended table B.4) N/A
G.4 Connectors N/A
G.4.1 Spacings N/A
G.4.2 Mains connector configuration ............................... : See table 4.1.2 N/A
G.4.3 Plug is shaped that insertion into mains socket- N/A
outlets or appliance coupler is unlikely
G.5 Wound components P
G.5.1 Wire insulation in wound components P
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
127 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 28 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.5.1.2 Protection against mechanical stress Physical separation between P
insulation wire and magnet
wire.
G.5.2 Endurance test N/A
G.5.2.1 General test requirements N/A
G.5.2.2 Heat run test N/A
Test time (days per cycle) ..................................... :
Test temperature ( C) ............................................ :
G.5.2.3 Wound components supplied from the mains N/A
G.5.2.4 No insulation breakdown N/A
G.5.3 Transformers P
G.5.3.1 Compliance method ............................................... : Meet the requirement of P
G.5.3.2 and G.5.3.3.
Position .................................................................. : T1 P
Method of protection .............................................. : Electronic circuits P
G.5.3.2 Insulation P
Protection from displacement of windings ............. : Workmanship and insulation
tape
G.5.3.3 Transformer overload tests (See appended table B.3) P
G.5.3.3.1 Test conditions P
G.5.3.3.2 Winding temperatures P
G.5.3.3.3 Winding temperatures - alternative test method N/A
G.5.3.4 Transformers using FIW N/A
G.5.3.4.1 General N/A
FIW wire nominal diameter .................................... :
G.5.3.4.2 Transformers with basic insulation only N/A
G.5.3.4.3 Transformers with double insulation or reinforced N/A
insulation ................................................................ :
G.5.3.4.4 Transformers with FIW wound on metal or ferrite N/A
core
G.5.3.4.5 Thermal cycling test and compliance N/A
G.5.3.4.6 Partial discharge test N/A
G.5.3.4.7 Routine test N/A
G.5.4 Motors No such component. N/A
G.5.4.1 General requirements N/A
G.5.4.2 Motor overload test conditions N/A
G.5.4.3 Running overload test N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
128 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 29 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.5.4.4.2 Locked-rotor overload test N/A
Test duration (days) .............................................. :
G.5.4.5 Running overload test for DC motors N/A
G.5.4.5.2 Tested in the unit N/A
G.5.4.5.3 Alternative method N/A
G.5.4.6 Locked-rotor overload test for DC motors N/A
G.5.4.6.2 Tested in the unit N/A
Maximum Temperature ........................................ : N/A
G.5.4.6.3 Alternative method N/A
G.5.4.7 Motors with capacitors N/A
G.5.4.8 Three-phase motors N/A
G.5.4.9 Series motors N/A
Operating voltage ................................................. :
G.6 Wire Insulation P
G.6.1 General P
G.6.2 Enamelled winding wire insulation P
G.7 Mains supply cords N/A
G.7.1 General requirements No such device. N/A
Type ....................................................................... :
G.7.2 Cross sectional area (mm2 or AWG) ..................... : N/A
G.7.3 Cord anchorages and strain relief for non- N/A
detachable power supply cords
G.7.3.2 Cord strain relief N/A
G.7.3.2.1 Requirements N/A
Strain relief test force (N) ....................................... : N/A
G.7.3.2.2 Strain relief mechanism failure N/A
G.7.3.2.3 Cord sheath or jacket position, distance (mm) ...... : N/A
G.7.3.2.4 Strain relief and cord anchorage material N/A
G.7.4 Cord Entry N/A
G.7.5 Non-detachable cord bend protection N/A
G.7.5.1 Requirements N/A
G.7.5.2 Test method and compliance N/A
Overall diameter or minor overall dimension, D
(mm) ...................................................................... :
Radius of curvature after test (mm) ....................... :
G.7.6 Supply wiring space N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
129 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 30 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.7.6.1 General requirements N/A
G.7.6.2 Stranded wire N/A
G.7.6.2.1 Requirements N/A
G.7.6.2.2 Test with 8 mm strand N/A
G.8 Varistors N/A
G.8.1 General requirements No such device. N/A
G.8.2 Safeguards against fire N/A
G.8.2.1 General N/A
G.8.2.2 Varistor overload test N/A
G.8.2.3 Temporary overvoltage test N/A
G.9 Integrated circuit (IC) current limiters N/A
G.9.1 Requirements No such device. N/A
IC limiter output current (max. 5A) ......................... :
.................................. :
G.9.2 Test Program N/A
G.9.3 Compliance N/A
G.10 Resistors N/A
G.10.1 General No such device. N/A
G.10.2 Conditioning N/A
G.10.3 Resistor test N/A
G.10.4 Voltage surge test N/A
G.10.5 Impulse test N/A
G.10.6 Overload test N/A
G.11 Capacitors and RC units P
G.11.1 General requirements Approved Y1 capacity used. P
G.11.2 Conditioning of capacitors and RC units P
G.11.3 Rules for selecting capacitors P
G.12 Optocouplers N/A
Optocouplers comply with IEC 60747-5-5 with No such device N/A
specifics
Type test voltage Vini,a............................................ :
Routine test voltage, Vini, b ..................................... :
G.13 Printed boards P
G.13.1 General requirements Approved PCB used. P
G.13.2 Uncoated printed boards P
G.13.3 Coated printed boards N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
130 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 31 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.13.4 Insulation between conductors on the same inner N/A
surface
G.13.5 Insulation between conductors on different surfaces N/A
Distance through insulation ................................... : N/A
Number of insulation layers (pcs) ......................... :
G.13.6 Tests on coated printed boards N/A
G.13.6.1 Sample preparation and preliminary inspection N/A
G.13.6.2 Test method and compliance N/A
G.14 Coating on components terminals N/A
G.14.1 Requirements ....................................................... : (See Clause G.13) N/A
G.15 Pressurized liquid filled components N/A
G.15.1 Requirements N/A
G.15.2 Test methods and compliance N/A
G.15.2.1 Hydrostatic pressure test N/A
G.15.2.2 Creep resistance test N/A
G.15.2.3 Tubing and fittings compatibility test N/A
G.15.2.4 Vibration test N/A
G.15.2.5 Thermal cycling test N/A
G.15.2.6 Force test N/A
G.15.3 Compliance N/A
G.16 IC including capacitor discharge function (ICX) N/A
G.16.1 Condition for fault tested is not required N/A
ICX with associated circuitry tested in equipment N/A
ICX tested separately N/A
G.16.2 Tests N/A
Smallest capacitance and smallest resistance
specified by ICX manufacturer for impulse test ..... :
Mains voltage that impulses to be superimposed on
............................................................................... :
Largest capacitance and smallest resistance for
ICX tested by itself for 10000 cycles test .............. :
G.16.3 Capacitor discharge test ........................................ : N/A
H CRITERIA FOR TELEPHONE RINGING SIGNALS N/A
H.1 General N/A
H.2 Method A N/A
H.3 Method B N/A
H.3.1 Ringing signal N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
131 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 32 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
H.3.1.1 Frequency (Hz) ..................................................... :
H.3.1.2 Voltage (V) ............................................................ :
H.3.1.3 Cadence; time (s) and voltage (V) ........................ :
H.3.1.4 Single fault current (mA): ....................................... :
H.3.2 Tripping device and monitoring voltage N/A
H.3.2.1 Conditions for use of a tripping device or a N/A
monitoring voltage
H.3.2.2 Tripping device N/A
H.3.2.3 Monitoring voltage (V) ........................................... : N/A
J INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED P
INSULATION
J.1 General P
Winding wire insulation .......................................... : Approved triple insulation wire
used as reinforced insulation.
Solid round winding wire, diameter (mm) .............. : See above. N/A
Solid square and rectangular (flatwise bending) N/A
winding wire, cross-sectional area (mm2) .............. :
J.2/J.3 Tests and Manufacturing
K SAFETY INTERLOCKS N/A
K.1 General requirements N/A
Instructional safeguard .......................................... : No safety interlocks inside the N/A
EUT.
K.2 Components of safety interlock safeguard mechanism N/A
K.3 Inadvertent change of operating mode N/A
K.4 Interlock safeguard override N/A
K.5 Fail-safe N/A
K.5.1 Under single fault condition N/A
K.6 Mechanically operated safety interlocks N/A
K.6.1 Endurance requirement N/A
K.6.2 Test method and compliance ................................ : N/A
K.7 Interlock circuit isolation N/A
K.7.1 Separation distance for contact gaps & interlock N/A
circuit elements
In circuit connected to mains, separation distance N/A
for contact gaps (mm)............................................ :
In circuit isolated from mains, separation distance N/A
for contact gaps (mm) ............................................ :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
132 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 33 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Electric strength test before and after the test of (See appended table 5.4.9) N/A
K.7.2 ...................................................................... :
K.7.2 Overload test, Current (A) ..................................... : N/A
K.7.3 Endurance test N/A
K.7.4 Electric strength test N/A
L DISCONNECT DEVICES N/A
L.1 General requirements N/A
L.2 Permanently connected equipment N/A
L.3 Parts that remain energized N/A
L.4 Single-phase equipment N/A
L.5 Three-phase equipment N/A
L.6 Switches as disconnect devices N/A
L.7 Plugs as disconnect devices N/A
L.8 Multiple power sources N/A
Instructional safeguard .......................................... : N/A
M EQUIPMENT CONTAINING BATTERIES AND THEIR PROTECTION CIRCUITS N/A
M.1 General requirements N/A
M.2 Safety of batteries and their cells N/A
M.2.1 Batteries and their cells comply with relevant IEC No battery used. N/A
standards ............................................................... :
M.3 Protection circuits for batteries provided within N/A
the equipment
M.3.1 Requirements N/A
M.3.2 Test method N/A
Overcharging of a rechargeable battery N/A
Excessive discharging N/A
Unintentional charging of a non-rechargeable N/A
battery
Reverse charging of a rechargeable battery N/A
M.3.3 Compliance (See appended table M.3) N/A
M.4 Additional safeguards for equipment containing a portable secondary lithium N/A
battery
M.4.1 General N/A
M.4.2 Charging safeguards N/A
M.4.2.1 Requirements N/A
M.4.2.2 Compliance ............................................................ : (See appended table M.4.2) N/A
M.4.3 Fire enclosure ........................................................ : N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
133 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 34 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
M.4.4 Drop test of equipment containing a secondary N/A
lithium battery
M.4.4.2 Preparation and procedure for the drop test N/A
M.4.4.3 Drop, Voltage on reference and dropped batteries N/A
(V); voltage difference during 24 h period (%): ..... :
M.4.4.4 Check of the charge/discharge function N/A
M.4.4.5 Charge / discharge cycle test N/A
M.4.4.6 Compliance N/A
M.5 Risk of burn due to short-circuit during carrying N/A
M.5.1 Requirement N/A
M.5.2 Test method and compliance N/A
M.6 Safeguards against short-circuits N/A
M.6.1 External and internal faults N/A
M.6.2 Compliance N/A
M.7 Risk of explosion from lead acid and NiCd batteries
M.7.1 Ventilation preventing explosive gas concentration N/A
Calculated hydrogen generation rate .................... : N/A
M.7.2 Test method and compliance N/A
Minimum air flow rate, Q (m3/h) ............................. : N/A
M.7.3 Ventilation tests N/A
M.7.3.1 General N/A
M.7.3.2 Ventilation test alternative 1 N/A
Hydrogen gas concentration (%) ........................... : N/A
M.7.3.3 Ventilation test alternative 2 N/A
Obtained hydrogen generation rate ....................... : N/A
M.7.3.4 Ventilation test alternative 3 N/A
Hydrogen gas concentration (%) ........................... : N/A
M.7.4 Marking .................................................................. : N/A
M.8 Protection against internal ignition from external spark sources of batteries N/A
with aqueous electrolyte
M.8.1 General N/A
M.8.2 Test method N/A
M.8.2.1 General N/A
M.8.2.2 Estimation of hypothetical volume VZ (m3/s).......... :
M.8.2.3 Correction factors .................................................. :
M.8.2.4 Calculation of distance d (mm) ............................. :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
134 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 35 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
M.9 Preventing electrolyte spillage N/A
M.9.1 Protection from electrolyte spillage N/A
M.9.2 Tray for preventing electrolyte spillage N/A
M.10 Instructions to prevent reasonably foreseeable N/A
misuse
Instructional safeguard .......................................... : N/A
N ELECTROCHEMICAL POTENTIALS N/A
Material(s) used ..................................................... : No such terminal needed to
considered electrochemical
erosion.
O MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES P
Value of X (mm) ..................................................... :
P SAFEGUARDS AGAINST CONDUCTIVE OBJECTS P
P.1 General No opening for the enclouse P
P.2 Safeguards against entry or consequences of entry of a foreign object N/A
P.2.1 General N/A
P.2.2 Safeguards against entry of a foreign object N/A
Location and Dimensions (mm) ............................ :
P.2.3 Safeguards against the consequences of entry of a N/A
foreign object
P.2.3.1 Safeguard requirements N/A
The ES3 and PS3 keep-out volume in Figure P.3 N/A
not applicable to transportable equipment
Transportable equipment with metalized plastic Not transportable equipment. N/A
parts ....................................................................... :
P.2.3.2 Consequence of entry test ..................................... : N/A
P.3 Safeguards against spillage of internal liquids N/A
P.3.1 General N/A
P.3.2 Determination of spillage consequences N/A
P.3.3 Spillage safeguards N/A
P.3.4 Compliance N/A
P.4 Metallized coatings and adhesives securing parts N/A
P.4.1 General N/A
P.4.2 Tests N/A
Conditioning, TC (°C) ............................................. :
Duration (weeks).................................................... :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
135 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 36 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Q CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING P
Q.1 Limited power sources P
Q.1.1 Requirements P
a) Inherently limited output N/A
b) Impedance limited output (See appended table Q.1) P
c) Regulating network limited output (See appended table Q.1) P
d) Overcurrent protective device limited output N/A
e) IC current limiter complying with G.9 N/A
Q.1.2 Test method and compliance ................................ : (See appended table Q.1) P
Current rating of overcurrent protective device (A) N/A
............................................................................... :
Q.2 Test for external circuits paired conductor No such construction N/A
cable
Maximum output current (A) ................................. : N/A
Current limiting method ......................................... :
R LIMITED SHORT CIRCUIT TEST N/A
R.1 General N/A
R.2 Test setup N/A
Overcurrent protective device for test.................... :
R.3 Test method N/A
Cord/cable used for test ........................................ :
R.4 Compliance N/A
S TESTS FOR RESISTANCE TO HEAT AND FIRE N/A
S.1 Flammability test for fire enclosures and fire barrier materials of equipment N/A
where the steady state power does not exceed 4 000 W
Samples, material .................................................. :
Wall thickness (mm) .............................................. :
Conditioning ( C) ................................................... :
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/A
S.2 Flammability test for fire enclosure and fire barrier integrity N/A
Samples, material .................................................. :
Wall thickness (mm) .............................................. :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
136 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 37 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Conditioning ( C) ................................................... :
S.3 Flammability test for the bottom of a fire enclosure N/A
S.3.1 Mounting of samples N/A
S.3.2 Test method and compliance N/A
Mounting of samples ............................................ :
Wall thickness (mm) .............................................. :
S.4 Flammability classification of materials N/A
S.5 Flammability test for fire enclosures and fire barrier materials of equipment N/A
where the steady state power exceeding 4 000 W
Samples, material .................................................. :
Wall thickness (mm) .............................................. :
Conditioning ( C) ................................................... :
T MECHANICAL STRENGTH TESTS P
T.1 General P
T.2 Steady force test, 10 N ....................................... : (See appended table T.2) P
T.3 Steady force test, 30 N ....................................... : (See appended table T.3) N/A
T.4 Steady force test, 100 N ..................................... : (See appended table T.4) N/A
T.5 Steady force test, 250 N ..................................... : (See appended table T.5) P
T.6 Enclosure impact test N/A
Fall test N/A
Swing test N/A
T.7 Drop test .............................................................. : N/A
T.8 Stress relief test ................................................... : (See appended table T.8) P
T.9 Glass Impact Test ................................................... : (See appended table T.9) N/A
T.10 Glass fragmentation test N/A
Number of particles counted..................................... : N/A
T.11 Test for telescoping or rod antennas N/A
Torque value (Nm) ................................................ : N/A
U MECHANICAL STRENGTH OF CATHODE RAY TUBES (CRT) AND PROTECTION N/A
AGAINST THE EFFECTS OF IMPLOSION
U.1 General N/A
Instructional safeguard : N/A
U.2 Test method and compliance for non-intrinsically protected CRTs N/A
U.3 Protective screen N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
137 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 38 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
V DETERMINATION OF ACCESSIBLE PARTS N/A
V.1 Accessible parts of equipment N/A
V.1.1 General For building-in product only, N/A
To be considered in the end
product.
V.1.2 Surfaces and openings tested with jointed test N/A
probes
V.1.3 Openings tested with straight unjointed test probes N/A
V.1.4 Plugs, jacks, connectors tested with blunt probe N/A
V.1.5 Slot openings tested with wedge probe N/A
V.1.6 Terminals tested with rigid test wire N/A
V.2 Accessible part criterion N/A
X ALTERNATIVE METHOD FOR DETERMINING CLEARANCES FOR INSULATION N/A
IN CIRCUITS CONNECTED TO AN AC MAINS NOT EXCEEDING 420 V PEAK
(300 V RMS)
Clearance .................................................................. : (See appended table X) N/A
Y CONSTRUCTION REQUIREMENTS FOR OUTDOOR ENCLOSURES N/A
Y.1 General N/A
Y.2 Resistance to UV radiation N/A
Y.3 Resistance to corrosion N/A
Y.3 Resistance to corrosion N/A
Y.3.1 Metallic parts of outdoor enclosures are resistant to N/A
effects of water-borne contaminants by ................ :
Y.3.2 Test apparatus N/A
Y.3.3 Water saturated sulphur dioxide atmosphere N/A
Y.3.4 Test procedure ....................................................... : N/A
Y.3.5 Compliance N/A
Y.4 Gaskets N/A
Y.4.1 General N/A
Y.4.2 Gasket tests N/A
Y.4.3 Tensile strength and elongation tests N/A
Alternative test methods ........................................ : N/A
Y.4.4 Compression test N/A
Y.4.5 Oil resistance N/A
Y.4.6 Securing means (See Annex P.4) N/A
Y.5 Protection of equipment within an outdoor enclosure N/A
Y.5.1 General N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
138 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 39 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Y.5.2 Protection from moisture N/A
Relevant tests of IEC 60529 or Y.5.3 .................... : N/A
Y.5.3 Water spray test N/A
Y.5.4 Protection from plants and vermin N/A
Y.5.5 Protection from excessive dust N/A
Y.5.5.1 General N/A
Y.5.5.2 IP5X equipment N/A
Y.5.5.3 IP6X equipment N/A
Y.6 Mechanical strength of enclosures N/A
Y.6.1 General N/A
Y.6.2 Impact test ............................................................. : (See Table T.6) N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
139 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 40 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.2 TABLE: Classification of electrical energy sources P
Supply Location (e.g. Test conditions Parameters ES
Voltage circuit Class
designation) U (V) I (mA) Type1) Additional
Info 2)
Normal -- -- -- --
Primary circuit
Abnormal -- -- -- --
275 directly connected ES3
to mains supply Single fault -- -- -- --
SC/OC:
Normal 4.94VDC -- -- --
Output of USB Abnormal 4.94VDC -- -- --
275 ES1
(5.0VDC,3A) Single fault 0 -- -- --
SC C6
Normal 8.95VDC
Output of USB Abnormal 8.95 VDC
275 ES1
(9.0VDC,2A) Single fault 0
SC C6
Normal 11.95
VDC
Output of USB Abnormal 11.95
275 ES1
(12.0VDC,1.5A) VDC
Single fault 0
SC C6
Supplementary information:
SC=Short Circuit.
1) Type: Steady state (SS), Capacitance (CP), Single pulse (SP), Repetitive pulses (RP), etc.
2) Additional Info: Frequency, Pulse duration, Pulse off time, Capacitance value, etc.
5.4.1.8 TABLE: Working voltage measurement P
RMS voltage Peak voltage Frequency Comments
Location
(V) (V) (Hz)
T1 pin 1-pin S 220 450 50 --
T1 pin 1-pin F 230 500 50 Max VRMS & Max
Vpeak
T1 pin 3-pin S 229 420 50 --
T1 pin 3-pin F 228 410 50 --
T1 pin 4-pin S 229 410 50 --
T1 pin 4-pin F 230 470 50 --
T1 pin 5-pin S 220 410 50 --
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
140 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 41 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
T1 pin 5-pin F 230 420 50 --
(CY1 ,CY2) Pri to Sec 182 340 50 --
U2 pin 1 pin 3 236 420 50 --
U2 pin 1 pin 4 226 410 50 --
U2 pin 2 pin 3 227 410 50 --
U2 pin 2 pin 4 228 420 50 --
Supplementary information: --
5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics N/A
Method ............................................................................................ : ISO 306 / B50
Object/ Part No./Material Manufacturer/trademark Thickness (mm) T softening (°C)
-- -- -- --
-- -- -- --
Supplementary information:--
5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics N/A
Method ............................................................................................ : ISO 306 / B50
Object/ Part No./Material Manufacturer/trademark Thickness (mm) T softening (°C)
-- -- -- --
-- -- -- --
Supplementary information:
5.4.1.10.3 TABLE: Ball pressure test of thermoplastics P
Allowed impression diameter (mm) ............................................... : 2 mm
Test Impression
Object/Part No./Material Manufacturer/trademark Thickness (mm)
temperature ( C) diameter (mm)
PCB See table 4.1.2 1.34 125 0.9
Bobbin See table 4.1.2 0.75 125 0.8
Supplementary information:--
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
141 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 42 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.2, 5.4.3 TABLE: Minimum Clearances/Creepage distance P
Clearance (cl) and Up Urms Freq 1) Required cl E.S. 2) Required cr
creepage distance (V) (V) (Hz) cl (mm) (mm) (V) cr (mm) (mm)
(cr) at/of/between:
Across mains fuse
2000 250 <30kHz 3.0 3.5 -- 3.0 3.5
FT1 (B)
L/N (B) 2000 250 <30kHz 3.0 3.5 -- 3.0 3.5
Primary to Secondary
2000 250 <30kHz 3.0 6.9 -- 5.5 6.9
(R)
Primary to accessible
2000 250 <30kHz 5.5 6.2 -- 5.5 6.2
conductive parts (R)
(CY1 ,CY2)Primary
2000 250 <30kHz 5.5 11.8 -- 5.5 11.8
to secondary (R)
PCB under
2000 250 <30kHz 5.5 10.4 -- 5.5 10.4
Transformer (T1) (R)
U2 Primary to
2000 250 <30kHz 5.5 6.2 -- 5.5 6.2
secondary (R)
Supplementary information:
Supplementary information: RI=Reinforce insulation, BI= Basic insulation, DI=Double insulation
1) Only for frequency above 30 kHz
2) Complete Electric Strength voltage (E.S. (V) when 5.4.2.4 applied)
3) Consider Overvoltage category III
5.4.4.2 TABLE: Minimum distance through insulation P
Distance through insulation Peak voltage (V) Insulation Required DTI Measured DTI
(DTI) at/of (mm) (mm)
Bobbin of transformer 500 RI 0.4 0.75
Supplementary information:--
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
142 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 43 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.4.9 TABLE: Solid insulation at frequencies >30 kHz N/A
Insulation material EP Frequency KR Thickness Insulation VPW
(kHz) d (mm) (Vpk)
-- -- -- -- -- -- --
-- -- -- -- -- -- --
Supplementary information:--
5.4.9 TABLE: Electric strength tests P
Test voltage applied between: Voltage shape Test voltage (V) Breakdown
(Surge, Impulse, AC, Yes / No
DC, etc.)
Basic/supplementary:
L to N (fuse open) DC 2500 No
L/N to USB output DC 4000 No
L/N Plastic enclosure DC 4000 No
Transformer primary to secondary DC 4000 No
Insulation tape around transformer per layer DC 4000 No
Supplementary information: --
5.5.2.2 TABLE: Stored discharge on capacitors N/A
Location Supply voltage (V) Operating and fault Switch Measured ES Class
condition 1) position voltage
(Vpk)
-- -- -- -- -- --
-- -- -- -- -- --
Supplementary information:
X-capacitors installed for testing:
bleeding resistor rating:
ICX:
1) Normal operating condition (e.g., normal operation, or open fuse), SC= short circuit, OC= open circuit
5.6.6 TABLE: Resistance of protective conductors and terminations N/A
Test current Duration Voltage drop Resistance
Location
(A) (min) (V) ( )
-- -- -- -- --
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
143 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 44 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
-- -- -- -- --
Supplementary information: --
5.7.4 TABLE: Unearthed accessible parts P
Location Operating and Supply Parameters ES
fault conditions Voltage (V) class
Voltage Current Freq.
(Vrms or Vpk) (Arms or Apk) (Hz)
L&N-Output -- 275 -- 0.068 -- ES1
L&N-plastic -- 275 -- 0.001 -- ES1
enclosure
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
5.7.5 TABLE: Earthed accessible conductive part N/A
Supply voltage (V) ........................... : --
Phase(s) ......................................... : [] Single Phase; [ ] Three Phase: [ ] Delta [ ] Wye
Power Distribution System ............. : TN TT IT
Location Fault Condition No in IEC Touch current Comment
60990 clause 6.2.2 (mA)
-- -- -- --
-- -- -- --
Supplementary Information: --
5.8 TABLE: Backfeed safeguard in battery backed up supplies N/A
Location Supply Operating and fault Time (s) Open-circuit Touch ES Class
voltage (V) condition voltage (V) current (A)
-- -- -- -- -- -- --
-- -- -- -- -- -- --
Supplementary information:
Abbreviation: SC= short circuit, OC= open circuit.
6.2.2 TABLE: Power source circuit classifications P
Location Operating and fault Voltage (V) Current (A) Max. Time (S) PS class
condition Power1)
(W)
All internal Normal or single PS3
-- -- -- --
circuit fault (Considered)
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
144 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 45 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Type C output Normal 4.94 3 14.82 >3s PS1
5Vdc, 3.0A
Type C output Normal 8.94 2 17.88 >5s PS2
9Vdc, 2.0A
Type C output Normal 11.94 1.51 18.03 >5s PS2
12Vdc, 1.5A
Type C output Overload 4.94 3.64 17.98 >5s PS2
5Vdc, 3.0A
Type C output C6 SC 0 0 0 >3s PS1
5Vdc, 3.0A
Type C output Overload 8.94 2.45 21.90 >5s PS2
9Vdc, 2.0A
Type C output C6 SC 0 0 0 >3s PS1
9Vdc, 2.0A
Type C output Overload 11.94 1.83 21.85 >5s PS2
12Vdc, 1.5A
Type C output C6 SC 0 0 0 >3s PS1
12Vdc, 1.5A
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
1) Measured after 3 s for PS1 and measured after 5 s for PS2 and PS3.
6.2.3.1 TABLE: Determination of Arcing PIS P
Location Open circuit voltage Measured r.m.s Calculated value Arcing PIS?
after 3 s (Vpk) current (A) Yes / No
-- -- -- -- --
Supplementary information:
Supplementary information: Considered Arcing PIS exist in PS3 and ES3 circuit.
An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the
product of the open circuit voltage (Vp) and normal operating condition rms current (Irms) is greater than
15.
6.2.3.2 TABLE: Determination of resistive PIS P
Location Operating and fault condition Dissipate power (W) Arcing PIS?
Yes / No
-- -- -- --
Supplementary information:
Supplementary Information: Considered Arcing PIS exist in PS3 and ES3 circuit.
A combination of voltmeter, VA and ammeter IA may be used instead of a wattmeter.
If a separate voltmeter and ammeter are used, the product of (VA x IA) is used to determine Resistive PIS
classification.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
145 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 46 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
A Resistive PIS: (a) dissipates more than 15 W, measured after 30 s of normal operation, or (b) under single
fault conditions has either a power exceeding 100 W measured immediately after the introduction of the fault
if electronic circuits, regulators or PTC devices are used, or has an available power exceeding 15 W
measured 30s after introduction of the fault.
8.5.5 TABLE: High pressure lamp N/A
Lamp manufacturer Lamp type Explosion method Longest axis of Particle found
glass particle beyond 1 m
(mm) Yes / No
-- -- -- -- --
-- -- -- -- --
Supplementary information:--
9.6 TABLE: Temperature measurements for wireless power transmitters N/A
Supply voltage (V).......................................... :
Max. transmit power of transmitter (W).......... :
w/o receiver and with receiver and with receiver and at with receiver and at
direct contact direct contact distance of 2 mm distance of 5 mm
Object Ambient Object Ambient Object Ambient Object Ambient
Foreign objects (oC) (oC) (oC) (oC) (oC) (oC) (oC) (oC)
-- -- -- -- -- -- -- -- --
-- -- -- -- -- -- -- -- --
Supplementary information:--
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
146 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 47 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.1.4, TABLE: Temperature measurements P
9.3, B.1.5,
B.2.6
Supply voltage (V).......................................... : 90V/60Hz 275V/60Hz
Ambient temperature during test Tamb ( C) .... : See Shift to See Shift to
below 35°C below 35°C
Maximum measured temperature T of part/at: T ( C) Allowed
Tmax ( C)
Input wire 88.0 101.0 73.4 85.3 105
C7 body 87.4 100.4 76.4 88.3 105
C8 body 83.7 96.7 76.1 88.0 105
CY1 body 70.2 83.2 70.8 82.7 125
CY2 body 64.1 77.1 66.2 78.1 125
U2 body 79.4 92.4 78.4 90.3 110
PCB near BD1 95.6 108.6 73.9 85.8 130
PCB near U1 99.6 112.6 98.0 109.9 130
PCB near U3 90.8 103.8 88.3 100.2 130
PCB near U3 for Type C board 65.6 78.6 65.7 77.6 130
T1 coil 86.7 99.7 87.7 99.6 110
T1 core 80.6 93.6 82.4 94.3 110
Plastic enclosure inside near T1 74.1 87.1 72.3 84.2 105
Plastic enclosure outside near T1 56.0 69.0 54.4 66.3 105
Ambient 22.0 35.0 23.1 35.0 --
Touch temperature accessible parts
Plastic enclosure outside 51.2 54.2 51.3 53.0 77
Ambient 22.0 25.0 23.1 25.0 --
Temperature T of winding: t1 (°C) R1 ( ) t2 (°C) R2 ( ) T ( C) Allowed Insulation
Tmax ( C) class
-- -- -- -- -- -- -- --
Supplementary information:
- The manufacture specified maximum operated ambient temperature is +35°C.
- All the test condition are under max operation by standard required.
- Output 9Vdc, 2.0A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
147 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 48 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.1.4, TABLE: Temperature measurements P
9.3, B.1.5,
B.2.6
Supply voltage (V).......................................... : 90V/60Hz 275V/60Hz
Ambient temperature during test Tamb ( C) .... : See Shift to See Shift to
below 35°C below 35°C
Maximum measured temperature T of part/at: T ( C) Allowed
Tmax ( C)
Input wire 82.8 96.1 87.4 100.2 105
C7 body 85.5 98.8 83.9 96.7 105
C8 body 82.3 95.6 81.4 94.2 105
CY1 body 67.7 81.0 74.3 87.1 125
CY2 body 60.8 74.1 68.2 81.0 125
U2 body 77.2 90.5 81.6 94.4 110
PCB near BD1 93.6 106.9 82.1 94.9 130
PCB near U1 98.7 112.0 102.4 115.2 130
PCB near U3 86.6 99.9 91.7 104.5 130
PCB near U3 for Type C board 60.8 74.1 66.6 79.4 130
T1 coil 83.7 97.0 91.5 104.3 110
T1 core 78.6 91.9 85.4 98.2 110
Plastic enclosure inside near T1 73.1 86.4 77.6 90.4 105
Plastic enclosure outside near T1 55.1 68.4 58.9 71.7 105
Ambient 21.7 35.0 22.2 35.0 --
Touch temperature accessible parts
Plastic enclosure outside 55.1 58.4 53.6 56.4 77
Ambient 21.7 25.0 22.2 25.0 --
Temperature T of winding: t1 (°C) R1 ( ) t2 (°C) R2 ( ) T ( C) Allowed Insulation
Tmax ( C) class
-- -- -- -- -- -- -- --
Supplementary information:
- The manufacture specified maximum operated ambient temperature is +35°C.
- All the test condition are under max operation by standard required.
- Output 12Vdc, 1.5A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
148 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 49 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.2.5 TABLE: Input test P
U (V) Hz I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status
90 50 0.358 -- 17.87 -- RT1 0.358 USB load with
3.0A, 5.0VDC.
100 50 0.351 0.5 17.81 -- RT1 0.351
250 50 0.186 0.5 18.25 -- RT1 0.186
275 50 0.158 -- 18.19 -- RT1 0.158
90 60 0.367 -- 17.88 -- RT1 0.367
100 60 0.348 0.5 17.79 -- RT1 0.348
250 60 0.185 0.5 18.16 -- RT1 0.185
275 60 0.161 -- 18.21 -- RT1 0.161
90 50 0.393 -- 20.91 -- RT1 0.393 USB load with
-- 2.0A, 9.0VDC.
100 50 0.392 0.5 20.86 RT1 0.392
250 50 0.212 0.5 20.90 -- RT1 0.212
275 50 0.182 -- 21.05 -- RT1 0.182
90 60 0.407 -- 20.92 -- RT1 0.407
100 60 0.392 0.5 20.82 -- RT1 0.392
250 60 0.212 0.5 21.02 -- RT1 0.212
275 60 0.183 -- 21.35 -- RT1 0.183
90 50 0.392 0.5 20.95 -- RT1 0.392 USB load with
1.5A, 12.0VDC.
100 50 0.385 0.5 20.87 -- RT1 0.385
250 50 0.209 -- 20.90 -- RT1 0.209
275 50 0.181 -- 21.06 -- RT1 0.181
90 60 0.407 0.5 20.97 -- RT1 0.407
100 60 0.394 0.5 20.89 -- RT1 0.394
250 60 0.212 -- 21.23 -- RT1 0.212
275 60 0.183 0.5 21.37 -- RT1 0.183
Supplementary information:--
Equipment may be have rated current or rated power or both. Both should be measured.
B.3, B.4 TABLE: Abnormal operating and fault condition tests P
Ambient temperature Tamb ( C) ..................................................... : 23.6
Power source for EUT: Manufacturer, model/type, outputrating .. : APS, AFC-31010, output
275
Component No. Condition Supply Test time Fuse no. Fuse Observation
voltage current
(V) (A)
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
149 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 50 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Unit operated normal until
output over load to 2.45A,
USB output
OL 275 100 mins TR1 0.215 2.45A unit shut down.
(9VDC,2A )
No higher temperature. No
hazard.
Unit operated normal until
output over load to 1.83A,
USB output
OL 275 120 mins TR1 0.235 1.83A unit shut down.
(12VDC,1.5A )
No higher temperature. No
hazard.
Unit shut down,no
BD1 pin + to - SC 275 1S TR1 0
hazard,fuse TR1 open
Unit shut down,no
C4 SC 275 1S TR1 0
hazard,fuse TR1 open
Unit shut down,no
C7 SC 275 1S TR1 0
hazard,fuse TR1 open
C6 SC 275 10mins TR1 0.074 Unit shut down, no hazard
T1 pin S-F SC 275 10mins TR1 0.012 Unit shut down, no hazard
C5 SC 275 10mins TR1 0.143 Unit normal work,no hazard
U2 pin1-2 SC 275 10mins TR1 0.006 Unit shut down, no hazard
U2 pin3-4 SC 275 10mins TR1 0.003 Unit shut down, no hazard
Type C port SC 275 10mins TR1 0.001 Unit shut down, no hazard
U1 pin3-10 SC 275 10mins TR1 0.003 Unit shut down, no hazard
U1 pin1-8 SC 275 10mins TR1 0.003 Unit shut down, no hazard
U1 pin1-4 SC 275 10mins TR1 0.003 Unit shut down, no hazard
Supplementary information:
SC=Short circuit, OL=Over load, OC=Open circuit.
M.3 TABLE: Protection circuits for batteries provided within the equipment N/A
Is it possible to install the battery in a reverse polarity position? ..... :
Charging
Equipment Specification Voltage (V) Current (A)
-- -
Battery specification
Non-rechargeable batteries Rechargeable batteries
Discharging Unintentional Charging Discharging Reverse
current (A) charging current (A) charging
Manufacturer/type Voltage (V) Current (A)
current (A) current (A)
-- -- -- -- -- -- --
Note: The tests of M.3.2 are applicable only when above appropriate data is not available.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
150 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 51 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Specified battery temperature ( oC) ................................................... : --
Component Fault Charge/ Test Temp. Current Voltage Observation
No. condition discharge mode time (oC) (A) (V)
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit NL= no chemical leakage; NS= no spillage of liquid; NE=
no explosion; NF= no emission of flame or expulsion of molten metal.
M.4.2 TABLE: Charging safeguards for equipment containing a secondary lithium N/A
battery
Maximum specified charging voltage (V) ..................................... : --
Maximum specified charging current (A) ..................................... : --
Highest specified charging temperature (oC) .............................. : --
Lowest specified charging temperature (oC) ............................... : --
Battery Operating Measurement Observation
manufacturer/type and fault
condition Charging Charging Temp.
voltage (V) current (A) (oC)
-- -- -- -- -- --
-- -- -- -- -- --
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified charging voltage; MSCC=
maximum specified charging current; HSCT= highest specified charging temperature; LSCT= lowest
specified charging temperature
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
151 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 52 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) P
Isc (A) S (VA)
Output Circuit Condition Uoc (V) Time (s)
Meas. Limit Meas. Limit
Type C output: Normal 4.94 5 3.64 8 17.78 100
5VDC, 3.0A
Type C output: C6 SC 0 5 0 8 0 100
5VDC, 3.0A
Type C output: Normal 8.95 5 2.45 8 21.93 100
9VDC, 2.0A
Type C output: C6 SC 0 5 0 8 0 100
9VDC, 2.0A
Type C output: Normal 11.95 5 1.83 8 21.87 100
12VDC, 1.5A
Type C output: C6 SC 0 5 0 8 0 100
12VDC, 1.5A
Supplementary Information:
SC= short circuit.
T.2, T.3, TABLE: Steady force test P
T.4, T.5
Force Test
Thickness
Part/Location Material Probe Duration Observation
(mm) (N) (s)
Connection of -- -- -- 10 5 Connection of
internal wire internal wire
Components -- -- -- 10 5 Components
Plastic enclosure Plastic Min1.5mm -- 250 5 Plastic enclosure
Supplementary information:--
T.6, T.9 TABLE: Impact test N/A
Location/part Material Thickness Height Observation
(mm) (mm)
-- -- -- -- --
Supplementary information:--
T.7 TABLE: Drop test N/A
Location/part Material Thickness Height Observation
(mm) (mm)
-- -- -- -- --
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
152 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 53 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:--
T.8 TABLE: Stress relief test P
Thickness Oven Temperature Duration
Location/Part Material Observation
(mm) ( C) (h)
Enclosure Plastic Min 1.5 87.6 7 Comply with standard.
Supplementary information:--
X TABLE: Alternative method for determining minimum clearances distances N/A
Clearance distanced Peak of working voltage Required cl Measured cl
between: (V) (mm) (mm)
-- -- -- --
Supplementary information:--
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
153 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 54 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4.1.2 TABLE: List of critical components P
Object / part Manufacturer/ Type / model Technical data Standard Mark(s) of
No. trademark conformity1
plastic Covestro Deutschland FR6005 + (z) PC, V-0, 105°C, UL 94 UL E41613
enclosure AG [PC Resins] min. thickness: 1.5
mm
Base SHANGHAI SUNNY HFP1010-R PP, V-0, 65°C, UL 94 UL
NEW TECHNOLOGY Min thickness E200750
1.8mm
Input lead Dongguan Zhongzhen 10368 22 AWG, 300V, UL7 58 UL
wire Cable Technology Co VW-1, 105°C E520580
Ltd
(Alternate) KUNSHAN XINGHONG 10368 22 AWG, 300V, UL 758 UL
MENG ELECTRONIC VW-1, 105°C E315421
CO.,LTD
(Alternate) DONGGUAN 10368 22 AWG, 300V, UL 758 UL
WENCHANG VW-1, 105°C E214500
ELECTRONIC CO LTD
Fuse Anhui Changsheng RXF21-1W 2.2 ohm, 1W EN IEC VDE
Resistors Electronics Co Ltd 62368-1: 40024768
(RT1) 2020 UL
Anhang / E306095
Annex G.10
IEC 62368-
1: 2018,
Anhang /
Annex G.10
TUBE of RT1 SHENZHEN WOER RSFR, SBRS 600V, VW-1, UL 224 UL
HEATSHRINKABLE 125°C E203950
MATERIAL CO LTD
(Alternate) CHANGYUAN CYG-ZHP, 600V, VW-1, UL 224 UL
ELECTRONICS GROUP CB-100 125°C E180908
CO LTD
PCB HUIZHOU XINGLIAN XL02 V-0, 130°C UL 746 UL
ELECTRONIC E346387
TECHNOLOGY CO LTD
(Alternate) SHEN ZHEN SHI CDX-2 V-0, 130°C UL 746 UL
CHANG DONG XIN E327349
PCB CO LTD
Y1 Capacitor MURATA MFG CO LTD KH AC 250VAC, EN 60384- VDE
(CY1,CY2) KL 2200pF, Y1, 14: 2013 40029300
RA 125°C +A1:2016 UL E37921
EA IEC 60384-
RA-Series 14: 2013
(VDE) +A1:2016
UL 60384-14
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
154 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 55 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
(Alternate) Guangdong Fenghua CT7 AC 400V, 1000pF, EN 60384- VDE
Advanced Technology CT7-Y1 (UL) Y1, 125°C 14: 2013 40013874
Holding CO., LTD +A1:2016 UL
IEC 60384- E219015
14: 2013
+A1:2016
UL 60384-14
Optocoupler EVERLIGHT EL1018 External IEC 60747- VDE
(U2) ELECTRONICS CO LTD 5-5:2007 40028391
External +A1:2013 UL
110 ºC EN 60747-5- E214129
5:2011
+A1:2015
UL 1577
(Alternate) LITE-ON Technology LTV-1008 External IEC 60747- VDE
Corporation 5-5:2007 138213
External +A1:2013 UL
110 ºC EN 60747-5- E113898
5:2011
+A1:2015
UL 1577
Transformer Matsuta Co., Ltd CNHY0001 130°C, Class B IEC 62368- Tested with
(T1) 1: 2018 appliance
EN IEC UL
62368-1: E336481
2020 + A11:
2020
(Alternate) HUI ZHOU XINTAI CNHY0001 130°C, Class B IEC 62368- Tested with
ELECTRONIC CO.,LTD 1: 2018 appliance
EN IEC UL
62368-1: E528537
2020 + A11:
2020
(Alternate) DONGGUAN HUALAI CNHY0001 130°C, Class B IEC 62368- Tested with
ELECTRONICEQUIPME 1: 2018 appliance
NT CO LTD EN IEC UL
62368-1: E504309
2020 + A11:
2020
- Bobbin SUMITOMO BAKELITE PM-9820 Phenolic Molding UL 94 UL E41429
CO LTD Compound, V-0,
150°C, min.
thickness 0.51mm
(Alternate) CHANG CHUN T200HF Phenolic Molding UL 94 UL E59481
PLASTICS CO LTD T375J Compound, V-0,
T375HF 150°C, min.
thickness 0.51mm
-Insulation JINGJIANG YAHUA CT-280B 130°C UL 510 UL
tape PRESSURE SENSITIVE E165111
GLUE CO LTD
(Alternate) SHEN ZHEN HMT803 130°C UL 510 UL
XINHUAHUI E328315
ELECTRONIC
MATERIALS CO LTD
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
155 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 56 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
(Alternate) JINGJIANG FUWEI FW 130°C UL 510 UL
ADHESIVE PRODUCT E302608
CO LTD
- Triple TA YA Electric Wire & TILW-B Reinforced EN 62368-1: VDE
insulated wire Cable Co., Ltd. insulation, rated 2014 / A11: 40019957
130°C 2017 UL
IEC 62368- E225803
1:2014
UL 2353
UL 60950-1
(Alternate) Shenzhen Kaizhong TIW-B (VDE) Reinforced EN 62368-1: VDE
Hedong New Materials TIW-B* (UL) insulation, rated 2014 / A11: 40038861
Co., Ltd. 130°C 2017 UL
IEC 62368- E357240
1:2014
UL 2353
UL 60950-1
(Alternate) Suzhou Yusheng TIW-B (VDE) Reinforced IEC 62368- VDE
Electronic Co., Ltd. TIW-B* (UL) insulation, rated 1:2018 40033527
130°C EN IEC UL
62368- E332529
1:2020+A11:
2020
UL 2353
UL 60950-1
-Teflon Tube GREAT HOLDING TFT 300V, VW-1, UL 224 UL
INDUSTRIAL CO LTD 200°C E156256
(Alternate) DONGGUAN LING LING FREE 300V, VW-1, UL 224 UL
FREE HARDWARE PTFE 200°C E352366
PLASTICS PRODUCT TUBE(300V)
CO LTD
(Alternate) Fluotech Industrial TFT 300V, VW-1, UL 224 UL
(Huizhou) Co Ltd 200°C E175982
- Magnet FENG CHING METAL UEW 130°C, MW75-C, UL 1446 UL
winding CORP E172395
(Alternate) HUIZHOU CITY X UEW 130°C, MW75-C, UL 1446 UL
DENGGAODA E253843
ELECTROTECH CO
LTD
(Alternate) SIHUI HENGHUI *UEW/155 or 130°C, MW79-C, UL 1446 UL
ELECTRICAL E337948
QA*/155 (@)
APPLIANCES CO LTD
(Alternate) DONGGUAN YIDA xUEW/130 or 130°C, MW75-C, UL 1446 UL
INDUSTRICAL CO LTD E344055
QA-x/130
- Varnish John C Dolph Co BC-346A 155°C UL 1446 UL
E317427
ZHUHAI CHANGXIAN E962 130°C UL 1446 UL
(Alternate) NEW MATERIALS E335405
TECHNOLOGY CO LTD
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
156 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 57 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
2) Description line content is optional. Main line description needs to clearly detail the component used for
testing
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
157 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 58 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Attachment 1: List of Europe National Differences
ATTACHMENT TO TEST REPORT
IEC 62368-1
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
(AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY
REQUIREMENTS)
Differences according to ............... : EN IEC 62368-1:2020+A11:2020
Attachment Form No. .................... : EU_GD_IEC62368_1E
Attachment Originator ................... : UL(Demko)
Master Attachment ......................... : 2021-02-04
Copyright © 2021 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS (EN) Noted
Clause numbers in the cells that are shaded light grey are clause references in EN Noted
IEC 62368-1:2020+A11:2020. All other clause numbers in that column, except for
those in the paragraph below, refers to IEC 62368-1:2018.
Clauses, subclauses, notes, tables, figures and annexes which are additional to
those in IEC 62368-
Add the following annexes: Noted
Annex ZA (normative) Normative references to international publications
with their corresponding European publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Annex ZD (informative) IEC and CENELEC code designations for flexible
cords
1 Modification to Clause 3. --
3.3.19 Sound exposure N/A
Replace 3.3.19 of IEC 62368-1 with the following definitions:
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
158 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 59 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
3.3.19.1 momentary exposure level, MEL N/A
metric for estimating 1 s sound exposure level from the
HD 483-1 S2 test signal applied to both channels,
based on EN 50332-1:2013, 4.2.
Note 1 to entry: MEL is measured as A-weighted levels in dB.
Note 2 to entry: See B.3 of EN 50332-3:2017 for additional
information.
3.3.19.3 sound exposure, E N/A
A-weighted sound pressure (p) squared and
integrated over a stated period of time, T
Note 1 to entry: The SI unit is Pa 2 s.
3.3.19.4 sound exposure level, SEL N/A
logarithmic measure of sound exposure relative to a
reference value, E0, typically the 1 kHz
threshold of hearing in humans.
Note 1 to entry: SEL is measured as A-weighted levels in dB.
dB
Note 2 to entry: See B.4 of EN 50332-3:2017 for additional
information.
3.3.19.5 digital signal level relative to full scale, dBFS N/A
levels reported in dBFS are always r.m.s. Full scale
level, 0 dBFS, is the level of a dc-free 997-
Hz sine wave whose undithered positive peak value is
positive digital full scale, leaving the code
corresponding to negative digital full scale unused
Note 1 to entry: It is invalid to use dBFS for non-r.m.s. levels.
Because the definition of full scale is based on a sine wave, the
level of signals with a crest factor lower than that of a sine wave
may exceed 0 dBFS. In particular, square wave signals may reach
+3,01 dBFS.
2 Modification to Clause 10 --
10.6 Safeguards against acoustic energy sources N/A
Replace 10.6 of IEC 62368-1 with the following:
10.6.1.1 Introduction Safeguard requirements for protection N/A
against long-term exposure to excessive sound
pressure levels from personal music players closely
coupled to the ear are specified below. Requirements
for earphones and headphones intended for use with
personal music players are also covered.
A personal music player is a portable equipment
intended for use by an ordinary person, that:
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
159 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 60 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
is designed to allow the user to listen to audio or
audiovisual content / material; and
uses a listening device, such as headphones or
earphones that can be worn in or on or
around the ears; and
has a player that can be body worn (of a size
suitable to be carried in a clothing pocket) and
is intended for the user to walk around with while in
continuous use (for example, on a street,
in a subway, at an airport, etc.).
EXAMPLES Portable CD players, MP3 audio players, mobile
phones with MP3 type features, PDAs or similar equipment.
Personal music players shall comply with the
requirements of either 10.6.2 or 10.6.3.
NOTE 1 Protection against acoustic energy sources from telecom
applications is referenced to ITU-T P.360.
NOTE 2 It is the intention of the Committee to allow the alternative
methods for now, but to only use the dose
measurement method as given in 10.6.5 in future. Therefore,
manufacturers are encouraged to implement 10.6.5 as soon as
possible.
Listening devices sold separately shall comply with the
requirements of 10.6.6.
These requirements are valid for music or video mode
only.
The requirements do not apply to:
professional equipment;
NOTE 3 Professional equipment is equipment sold through special
sales channels. All products sold through
normal electronics stores are considered not to be professional
equipment.
hearing aid equipment and other devices for
assistive listening;
the following type of analogue personal music
players:
long distance radio receiver (for example, a
multiband radio receiver or world band radio
receiver, an AM radio receiver), and
cassette player/recorder;
NOTE 4 This exemption has been allowed because this technology
is falling out of use and it is expected that
within a few years it will no longer exist. This exemption will not be
extended to other technologies.
a player while connected to an external amplifier that
does not allow the user to walk around
while in use.
For equipment that is clearly designed or intended
primarily for use by children, the limits of the
relevant toy standards may apply.
The relevant requirements are given in
EN 71-1:2011, 4.20 and the related tests methods and
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
160 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 61 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
measurement distances apply.
10.6.1.2 Non-ionizing radiation from radio frequencies in N/A
the range 0 to 300 GHz
The amount of non-ionizing radiation is regulated by
European Council Recommendation 1999/519/EC of
12 July 1999 on the limitation of exposure of the
general public to electromagnetic fields (0 Hz to 300
GHz).
For intentional radiators, ICNIRP guidelines should be
taken into account for Limiting Exposure to Time-
Varying Electric, Magnetic, and Electromagnetic Fields
(up to 300 GHz). For hand-held and body mounted
devices, attention is drawn to EN 50360 and EN
50566.
10.6.2 Classification of devices without the capacity to estimate sound dose N/A
10.6.2.1 General N/A
This standard is transitioning from short-term based
(30 s) requirements to long-term based (40 hour)
requirements. These clauses remain in effect only for
devices that do not comply with sound dose estimation
as stipulated in EN 50332-3.
For classifying the acoustic output LAeq,T ,
measurements are based on the A-weighted
equivalent sound pressure level over a 30 s period.
For music where the average sound pressure (long
term LAeq,T) measured over the duration of the song is
lower than the average produced by the programme
simulation noise, measurements may be done over
the duration of the complete song. In this case, T
becomes the duration of the song.
NOTE Classical music, acoustic music and broadcast typically has
an average sound pressure (long term LAeq,T) which is much lower
than the average programme simulation noise. Therefore, if the
player is capable to analyse the content and compare it with the
programme simulation noise, the warning does not need to be given
as long as the average sound pressure of the song does not e xceed
the required limit.
For example, if the player is set with the programme simulation
noise to 85 dB, but the average music level of the song is only 65
dB, there is no need to give a warning or ask an acknowledgement
as long as the average sound level of the song is not above the
basic limit of 85 dB.
10.6.2.2 RS1 limits (to be superseded, see 10.6.3.2) N/A
RS1 is a class 1 acoustic energy source that does not
exceed the following:
for equipment provided as a package (player with its
listening device), and with a proprietary connector
between the player and its listening device, or where
the combination of player and listening device is
known by other means such as setting or automatic
detection, the LAeq,T acoustic output shall be 85 dB
described in EN 50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that allows
connection to a listening device for general use, the
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
161 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 62 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
unweighted r.m.s. output voltage shall be 27 mV
(analogue interface) or -25 dBFS (digital interface)
described in EN 50332-1.
The RS1 limits will be updated for all devices as per
10.6.3.2.
10.6.2.3 RS2 limits (to be superseded, see 10.6.3.3) N/A
RS2 is a class 2 acoustic energy source that does not
exceed the following:
for equipment provided as a package (player with its
listening device), and with a proprietary connector
between the player and its listening device, or when
the combination of player and listening device is
known by other means such as setting or automatic
130 detection, the LAeq,T acoustic output shall be
-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that allows
connection to a listening device for general use, the
unweighted r.m.s. output voltage shall be 150 mV
(analogue interface) or -10 dBFS (digital interface)
as described in EN 50332-1.
10.6.2.4 RS3 limits N/A
RS3 is a class 3 acoustic energy source that exceeds
RS2 limits.
10.6.3 Classification of devices (new) N/A
10.6.3.1 General N/A
Previous limits (10.6.2) created abundant false
negative and false positive PMP sound level warnings.
New limits, compliant with The Commission Decision
of 23 June 2009, are given below.
10.6.3.2 RS1 limits (new) N/A
RS1 is a class 1 acoustic energy source that does not
exceed the following:
for equipment provided as a package (player with
its listening device), and with a proprietary connector
between the player and its listening device, or where
the combination of player and listening device is
known by other means such as setting or automatic
detection, the LAeq,T acoustic output shall be 80 dB
described in EN 50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that allows
connection to a listening device for general use, the
unweighted r.m.s. output voltage shall be 15 mV
(analogue interface) or -30 dBFS (digital interface)
when
described in EN 50332-1.
10.6.3.3 RS2 limits (new) N/A
RS2 is a class 2 acoustic energy source that does not
exceed the following:
for equipment provided as a package (player with its
listening device), and with a proprietary connector
between the player and its listening device, or where
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
162 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 63 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
the combination of player and listening device is
known by other means such as setting or automatic
detection, the weekly sound exposure level, as
described in EN 50332-3, shall be 80 dB when
playing the fixed "programme simulation noise"
described in EN 50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that allows
connection to a listening device for general use, the
unweighted r.m.s. output level, integrated over one
week, as described in EN50332-3, shall be 15 mV
(analogue interface) or -30 dBFS (digital interface)
described in EN 50332-1.
10.6.4 Requirements for maximum sound exposure N/A
10.6.4.1 Measurement methods N/A
All volume controls shall be turned to maximum during
tests.
Measurements shall be made in accordance with EN
50332-1 or EN 50332-2 as applicable.
10.6.4.2 Protection of persons N/A
Except as given below, protection requirements for
parts accessible to ordinary persons, instructed
persons and skilled persons are given in 4.3.
NOTE 1 Volume control is not considered a safeguard.
Between RS2 and an ordinary person, the basic
safeguard may be replaced by an instructional
safeguard in accordance with Clause F.5, except that
the instructional safeguard shall be placed on the
equipment, or on the packaging, or in the instruction
manual.
Alternatively, the instructional safeguard may be
given through the equipment display during use.
The elements of the instructional safeguard shall be
as follows:
element 1a: the symbol , IEC 60417-6044
(2011-01)
wording
wording
An equipment safeguard shall prevent exposure of
an ordinary person to an RS2 source without
intentional physical action from the ordinary person
and shall automatically return to an output level not
exceeding what is specified for an RS1 source when
the power is switched off.
The equipment shall provide a means to actively
inform the user of the increased sound level when the
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
163 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 64 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
equipment is operated with an output exceeding RS1.
Any means used shall be acknowledged by the user
before activating a mode of operation which allows for
an output exceeding RS1. The acknowledgement
does not need to be repeated more than once every
20 h of cumulative listening time.
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always needed.
NOTE 3 The 20 h listening time is the accumulative listening time,
independent of how often and how long the personal music player
has been switched off.
A skilled person shall not be unintentionally exposed
to RS3.
10.6.5 Requirements for dose-based systems N/A
10.6.5.1 General requirements N/A
Personal music players shall give the warnings as
provided below when tested according to EN 50332-3,
using the limits from this clause.
The manufacturer may offer optional settings to allow
the users to modify when and how they wish to
receive the notifications and warnings to promote a
better user experience without defeating the
safeguards. This allows the users to be informed in a
method that best meets their physical capabilities and
device usage needs. If such optional settings are
offered, an administrator (for example, parental
restrictions, business/educational administrators, etc.)
shall be able to lock any optional settings into a
specific configuration.
The personal music player shall be supplied with easy
to understand explanation to the user of the dose
management system, the risks involved, and how to
use the system safely. The user shall be made aware
that other sources may significantly contribute to their
sound exposure, for example work, transportation,
concerts, clubs, cinema, car races, etc.
10.6.5.2 Dose-based warning and requirements N/A
When a dose of 100 % CSD is reached, and at least
at every 100 % further increase of CSD, the device
shall warn the user and require an acknowledgement.
In case the user does not acknowledge, the output
level shall automatically decrease to compliance with
class RS1.
The warning shall at least clearly indicate that listening
above 100 % CSD leads to the risk of hearing damage
or loss.
10.6.5.3 Exposure-based requirements N/A
With only dose-based requirements, cause and effect
could be far separated in time, defying the purpose of
educating users about safe listening practice. In
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
164 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 65 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
addition to dose-based requirements, a PMP shall
therefore also put a limit to the short-term sound level
a user can listen at.
The exposure-based limiter (EL) shall automatically
reduce the sound level not to exceed 100 dB(A) or
150 mV integrated over the past 180 s, based on
methodology defined in EN 50332-3.
The EL settling time (time from starting level reduction
to reaching target output) shall be 10 s or faster.
Test of EL functionality is conducted according to EN
50332-3, using the limits from this clause. For
equipment provided as a package (player with its
listening device), the level integrated over 180 s shall
be 100 dB or lower. For equipment provided with a
standardized connector, the unweighted level
integrated over 180 s shall be no more than 150 mV
for an analogue interface and no more than -10 dBFS
for a digital interface.
NOTE In case the source is known not to be music (or test signal),
the EL may be disabled.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
165 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 66 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
10.6.6 Requirements for listening devices (headphones, earphones, etc.) N/A
10.6.6.1 Corded listening devices with analogue input
With 94 dB LAeq acoustic pressure output of the
listening device, and with the volume and sound
settings in the listening device (for example, built-in
volume level control, additional sound features like
equalization, etc.) set to the combination of positions
that maximize the measured acoustic output, the input
voltage of the listening device when playing the fixed
50332-1 shall be 75 mV.
NOTE The values of 94 dB and 75 mV correspond with 85 dB and
27 mV or 100 dB and 150 mV.
10.6.6.2 Corded listening devices with digital input N/A
-1, and with
the volume and sound settings in the listening device
(for example, built-in volume level control, additional
sound features like equalization, etc.) set to the
combination of positions that maximize the measured
acoustic output, the LAeq,T acoustic output of the
listening device shall be 100 dB with an input signal
of -10 dBFS.
10.6.6.3 Cordless listening devices N/A
In cordless mode,
with any playing and transmitting device playing the
fixed programme simulation noise described in EN
50332-1; and
respecting the cordless transmission standards,
where an air interface standard exists that specifies
the equivalent acoustic level; and
with volume and sound settings in the receiving
device (for example, built-in volume level control,
additional sound features like equalization, etc.) set to
the combination of positions that maximize the
measured acoustic output for the above mentioned
programme simulation noise, the LAeq,T acoustic output
of the listening device shall be 100 dB with an input
signal of -10 dBFS.
10.6.6.4 Measurement method N/A
Measurements shall be made in accordance with EN
50332-2 as applicable.
3 Modification to the whole document --
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
166 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 67 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Delete ccording to the following Noted
list:
4 Modification to Clause 1 --
1 Add the following note: N/A
NOTE Z1 The use of certain substances in electrical and electronic
equipment is restricted within the EU: see Directive 2011/65/EU.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
167 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 68 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5 Modification to 4.Z1 --
4.Z1 Add the following new subclause after 4.9: N/A
To protect against excessive current, short-circuits
and earth faults in circuits connected to an a.c.
mains, protective devices shall be included either
as integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of B.3.1 and B.4 shall be included as parts of the
equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;
c) it is permitted for pluggable equipment type B
or permanently connected equipment, to rely on
dedicated overcurrent and short-circuit protection
in the building installation, provided that the means
of protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for pluggable equipment type
A the building installation shall be regarded as
providing protection in accordance with the rating
of the wall socket outlet.
6 Modification to 5.4.2.3.2.4 --
5.4.2.3.2.4 Add the following to the end of this subclause: N/A
The requirement for interconnection with external
circuit is in addition given in EN 50491-3:2009.
7 Modification to 10.2.1 --
10.2.1 Add the following to c) and d) in table 39: N/A
For additional requirements, see 10.5.1.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
168 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 69 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8 Modification to 10.5.1 --
10.5.1 Add the following after the first paragraph: N/A
For RS 1 compliance is checked by measurement
under the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside by hand, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Z1 Soldered joints and paint lockings are examples of
adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
For RS1, the dose-rate shall not exceed 1
taking account of the background level.
NOTE Z2 These values appear in Directive 96/29/Euratom of 13
May 1996.
9 Modification to G.7.1 --
G.7.1 Add the following note: N/A
NOTE Z1 The harmonized code designations corresponding to
the IEC cord types are given in Annex ZD.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
169 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 70 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
10 Modification to Bibliography --
Add the following notes for the standards indicated: N/A
11 ADDITION OF ANNEXES --
ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN ) N/A
4.1.15 Denmark, Finland, Norway and Sweden N/A
To the end of the subclause the following is
added:
Class I pluggable equipment type A intended
for connection to other equipment or a
network shall, if safety relies on connection to
reliable earthing or if surge suppressors
are connected between the network terminals and
accessible parts, have a marking stating that the
equipment shall be connected to an earthed
mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Denmark
stikkontakt med jord som giver forbindelse til
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway
In Sweden
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
170 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 71 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4.7.3 United Kingdom N/A
To the end of the subclause the following is added:
The torque test is performed using a socket-outlet
complying with BS 1363, and the plug part shall be
assessed to the relevant clauses of BS 1363. Also see
Annex G.4.2 of this annex
5.2.2.2 Denmark N/A
After the 2nd paragraph add the following:
A warning (marking safeguard) for high touch current
is required if the touch current exceeds the limits of
3,5 mA a.c. or 10 mA d.c.
5.4.11.1 Finland and Sweden N/A
and
Annex G To the end of the subclause the following is added:
For separation of the telecommunication network from
earth the following is applicable:
If this insulation is solid, including insulation forming
part of a component, it shall at least
consist of either
two layers of thin sheet material, each of which
shall pass the electric strength test below, or
one layer having a distance through insulation of at
least 0,4 mm, which shall pass the electric strength
test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that clearances and
creepage distances do not exist, if the component
passes the electric strength test in accordance with
the compliance clause below and in addition
passes the tests and inspection criteria of 5.4.8 with
an electric strength test of 1,5 kV multiplied by 1,6
(the electric strength test of 5.4.9 shall be performed
using 1,5 kV),
and
is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5
kV.
It is permitted to bridge this insulation with a capacitor
complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to EN 60384-
14:2005, may bridge this insulation under
the following conditions:
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
171 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 72 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
the insulation requirements are satisfied by having
a capacitor classified Y3 as defined by EN 60384-
14, which in addition to the Y3 testing, is tested
with an impulse test of 2,5 kV defined in 5.4.11;
test specimens as described in EN 60384-14;
the impulse test of 2,5 kV is to be performed before
the endurance test in EN 60384-14, in the sequence
of tests as described in EN 60384-14.
5.5.2.1 Norway N/A
After the 3rd paragraph the following is added:
Due to the IT power system used, capacitors are
required to be rated for the applicable line-to-line
voltage (230 V).
5.5.6 Finland, Norway and Sweden N/A
To the end of the subclause the following is added:
Resistors used as basic safeguard or bridging basic
insulation in class I pluggable equipment type A
shall comply with G.10.1 and the test of G.10.2.
5.6.1 Denmark N/A
Add to the end of the subclause
Due to many existing installations where the socket-
outlets can be protected with fuses
with higher rating than the rating of the socket-outlets
the protection for pluggable
equipment type A shall be an integral part of the
equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
5.6.4.2.1 Ireland and United Kingdom N/A
After the indent for pluggable equipment type A, the
following is added:
the protective current rating is taken to be 13 A,
this being the largest rating of fuse used in the mains
plug.
5.6.4.2.1 France N/A
After the indent for pluggable equipment type A, the
following is added:
in certain cases, the protective current rating of
the circuit supplied from the mains is taken as 20 A
instead of 16 A.
5.6.5.1 To the second paragraph the following is added: N/A
The range of conductor sizes of flexible cords to be
accepted by terminals for equipment with a rated
current over 10 A and up to and including 13 A is:
1,25 mm2 to 1,5 mm2 in cross-sectional area.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
172 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 73 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.6.8 Norway N/A
To the end of the subclause the following is added:
Equipment connected with an earthed mains plug is
classified as class I equipment. See the Norway
marking requirement in 4.1.15. The symbol IEC
60417-6092, as specified in F.3.6.2, is accepted.
5.7.6 Denmark N/A
To the end of the subclause the following is added:
The installation instruction shall be affixed to the
equipment if the protective conductor current
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.
5.7.6.2 Denmark N/A
To the end of the subclause the following is added:
The warning (marking safeguard) for high touch
current is required if the touch current or the protective
current exceed the limits of 3,5 mA .
5.7.7.1 Norway and Sweden N/A
To the end of the subclause the following is added:
The screen of the television distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding system
within the building.
Therefore the protective earthing of the building
installation needs to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by a retailer, for example.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what country
the equipment is intended to be used in:
connected to the protective earthing of the
building installation through the mains connection or
through other apparatus with a connection to
protective earthing
and to a television distribution system using coaxial
cable, may in some circumstances create a fire
hazard. Connection to a television distribution system
therefore has to be provided through a device
providing electrical isolation below a certain frequency
range (galvanic isolator, see EN 60728-
NOTE In Norway, due to regulation for CATV-
installations, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The
insulation shall withstand a dielectric strength of 1,5
kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
173 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 74 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
be accepted in Norway):
nettplugg og/eller via annet jordtilkoplet
utstyr og er tilkoplet et koaksialbasert kabel-TV nett,
kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av apparater
til kabel-TV nett installeres en
galvanisk isolator mellom apparatet og kabel-TV
Translation to Swedish:
vägguttag och/eller via annan utrustning och samtidigt
är kopplad till kabel-TV nät kan i vi
apparaten till kabel-TV nät galvanisk isolator finnas
mellan apparaten och kabel-
8.5.4.2.3 United Kingdom N/A
Add the following after the 2nd dash bullet in 3rd
paragraph:
An emergency stop system complying with the
requirements of IEC 60204-1 and ISO 13850 is
required where there is a risk of personal injury.
B.3.1 and Ireland and United Kingdom N/A
B.4 The following is applicable:
To protect against excessive currents and short-
circuits in the primary circuit of direct plug-in
equipment, tests according to Annexes B.3.1 and B.4
shall be conducted using an external miniature circuit
breaker complying with EN 60898-1, Type B, rated
32A. If the equipment does not pass these tests,
suitable protective devices shall be included as an
integral part of the direct plug-in equipment, until the
requirements of Annexes B.3.1 and B.4 are met
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
174 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 75 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.4.2 Denmark N/A
To the end of the subclause the following is added:
Supply cords of single phase appliances having a
rated current not exceeding 13 A shall be provided
with a plug according to DS 60884-2-D1:2011.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a polyphase
equipment is provided with a supply cord with a plug,
this plug shall be in accordance with the standard
sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2.
Mains socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A shall
be in accordance DS 60884-2-D1:2011 standard
sheet DKA 1-4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet DKA 1-3a
or DKA 1-1c.
Mains socket-outlets with earth shall be in compliance
with DS 60884-2-D1:2011
Standard Sheet DK 1-3a, DK 1-1c, DK1-1d, DK 1-5a
or DK 1-7a
Justification:
Heavy Current Regulations, Section 6c
G.4.2 United Kingdom N/A
To the end of the subclause the following is added:
The plug part of direct plug-in equipment shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9,
12.11, 12.12, 12.13, 12.16, and 12.17, except that the
test of 12.17 is performed at not less than 125 °C.
Where the metal earth pin is replaced by an Insulated
Shutter Opening Device (ISOD), the requirements of
clauses 22.2 and 23 also apply.
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
175 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 76 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.7.1 United Kingdom N/A
To the first paragraph the following is added:
Equipment which is fitted with a flexible cable or cord
and is designed to be connected to a mains socket
conforming to BS 1363 by means of that flexible cable
accordance with the Plugs and Sockets etc. (Safety)
Regulations 1994, Statutory Instrument 1994 No.
1768, unless exempted by those
regulations.
NOTE "Standard plug" is defined in SI 1768:1994 and essentially
means an approved plug conforming to BS 1363 or an approved
conversion plug.
G.7.1 Ireland N/A
To the first paragraph the following is added:
Apparatus which is fitted with a flexible cable or cord
shall be provided with a plug in accordance with
Conversion Adapters for Domestic Use Regulations:
1997. S.I. 525 provides for the recognition of a
standard of another Member State which is equivalent
to the relevant Irish Standard
G.7.2 Ireland and United Kingdom N/A
To the first paragraph the following is added:
A power supply cord with a conductor of 1,25 mm 2 is
allowed for equipment which is rated over 10 A and up
to and including 13 A.
ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A
10.5.2 Germany N/A
The following requirement applies:
For the operation of any cathode ray tube intended for
the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization is
required, or application of type
approval (Bauartzulassung) and marking.
Justification:
German ministerial decree against ionizing radiation
(Röntgenverordnung), in force since
2002-07-01, implementing the European Directive
96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt, Bundesallee 100, D- 38116
Braunschweig,
Tel.: Int+49-531-592-6320, Internet: http://www.ptb.de
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
176 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 77 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
ZD IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS (EN) N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
177 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 78 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Attachment 2: USB output test according to IEC 62368-3: 2017 and
EN IEC 62368-3: 2020
4 General Requirements P
Equipment serving as a PD or a PSE using voltages ES1 P
at ES1 or ES2,
Equipment used as PSE or PD with proprietary N/A
connectors
Equipment where a proprietary protocol is used to N/A
enable the power transfer
5 POWER TRANSFER USING ES1 OR ES2 VOLTAGES P
5.1 General requirements P
Maximum rated output voltage of PSE................ : 5.0V/9.0V/12.0V
under conditions of no load .................................. : 4.94V/8.95V/11.95V
normal load .......................................................... : 4.94V/8.95V/11.95V
maximum rated load ............................................ : 4.94V/8.94V/11.94V
Rated limits of intended communication systems: N/A
PD or PSE have the capability to both provide N/A
power and receive power
5.2 Electrical-caused injury, electrical sources and safeguards P
For a PSE classified as ES1 and ES2, the P
requirements of IEC 62368-1 clause 5.2 apply.
5.3 Electrical-caused fire, power sources and safeguards P
5.3.1 Output power reduces the likelihood of ignition. P
Output current does not cause damage to (see below) P
communication cables, building wiring, and other
devices including PD.
PSE circuits comply with IEC 62368 1:2014, Q.1 P
requirements for limited power source (LPS).
Interconnection of PSE circuits to other devices N/A
for DC power transfer via building wiring
PSE maximum continuous current [A] ................ :
Minimum wire gauge specified in the equipment
installation instructions. ........................................ :
Current limits of minimum wire gauge ................. :
PD receives multiple PSE power inputs. Not such construction N/A
PD implements power limiting in accordance with
PS2 or IEC 62368-1:2014, Annex Q
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
178 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 79 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
PSE connected to external paired conductor N/A
cable having a minimum wire diameter of 0.4 mm
(IEC 62368-1:2014, Table 14, ID 1 and 2
IEC 62368-1:2018, Table 13, ID 1 and 2)
Current limited to not more than 1.3 A ................ : N/A
5.3.2 DC power transfer interconnection to other Compliance with Clause Q.1 P
equipment, where it is unknown that attached
devices are likely to comply with IEC 62368-1,
PSE circuit shall comply with requirements of
IEC 62368 1:2014 for PS2 or Clause Q.1
Available output current under abnormal N/A
operating conditions and single fault conditions in
the PSE does not exceed the specified fault
current rating in power delivery specification.
Fault current rating in power delivery specification
(A) ......................................................................... :
Available output current under abnormal
operating conditions and single fault conditions in
the PSE (A) ......................................................... :
No prescribed maximum fault current specified for 3.9A for 5VDC ,3A; 3A for P
standardized interface. 9VDC, 2A ; 2.25A for 12VDC,
1.5A
Available current not exceeding:
8.0 A under any circumstances P
Circuits > 2 A, 130% for more than 5 s ............... : 3.9A/2.25A P
............. : 3A P
5.4 Safeguards to protect against a single fault condition in the PSE P
5.4.1 Requirement for the PSE P
PSE with a single output voltage ..................... : N/A
Nominal rated output voltage ............................... :
Single fault conditions output voltage ................ :
ES2 limit (DC 120V, 50V RMS, 70.7 V peak) P
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
179 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 80 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
PSE delivering a range of output voltages via 5.0V/9.0V/12.0V P
negotiation with the PD ..................................... :
Single fault conditions output voltage ................ : See below
Negotiated > 5 V, output 130% (min. 7.5 V) ..... : 11.7V/15.6V P
......................... : 7.5V P
5.4.2 Requirement for the PD The equipment serves as PSE N/A
Nominal rated input voltage .............................. : See above
Nominal > 5 V, supplied with 130% (min. 7.5 V) .: N/A
................... : N/A
Any consequential failure of components in the N/A
PD ......................................................................... :
6 POWER TRANSFER USING RFT N/A
6.1 General requirements N/A
Access to RFT circuit conductors is restricted to a N/A
skilled person ....................................................... :
Access by an instructed person is restricted in N/A
accordance with IEC 62368-1:2014, clause 5.3.2.1
and 5.3.2.2 ........................................................ :
6.2 Connection to ICT networks N/A
RFT circuit directly connected to an ICT network :
6.3 Electrically caused injury N/A
6.3.1.1.1 The current limits in 6.3.1.1.2 to 6.3.1.1.4 are See appended table 6.3.1.1 N/A
inherently met.
The RFT-C circuit has a monitoring and control N/A
device that maintains the required current limits
6.3.1.1.2 Limits under normal operating conditions N/A
a) steady state current from supply equipment into N/A
ICT network under any load condition (mA) ....... :
b) N/A
state current from one conductor of equipment
through ICT network to earth (mA) ..................... :
c) RFT-C circuit is limited to voltage rating of ICT N/A
network wiring, if this voltage is known (V) ......... :
d) RFT-C circuit voltage rating of insulation between N/A
conductors and from any conductor to earth is
coordinated with max. RFT-C circuit supply
equipment voltage (V) ......................................... :
6.3.1.1.3 Current measured under single fault conditions did See appended table 6.3.1.1
not exceed the line-to-earth and line-to-line limits in
Figure 1
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
180 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 81 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.3.1.1.4 Current limits with one RFT-C conductor accidentally
earthed, between the other conductor and earth
any external load condition ................................. :
Current not exceeding line-to-earth limits in N/A
Figure 1 with a limit of 25 mA after 10 s.............. :
Open circuit voltage between other conductor and N/A
earth not exceeding maximum RFT-C circuit voltage
determined in 6.3.1.1.2 c) and 6.3.1.1.2 d), after 2 s
.............................................................................. :
6.3.1.2 RFT-V circuit limits See appended table 6.3.1.2
6.3.1.2.1 Limits under normal operating conditions
Steady state open circuit voltage between earth and N/A
each RFT-V circuit conductor that normally connects
to an ICT network, not exceeding (V)
- 140 V DC .......................................................... :
- 200 V DC with monitoring and control device in
accordance with 6.3.1.2.3 ................................... :
Voltage rating of insulation of RFT-V circuit receiving N/A
power via ICT network is suitable for
- 400 V between conductors and
- 200 V from any conductor to earth ................... :
6.3.1.2.2 Voltage limits within RFT-V circuit supply equipment N/A
under single fault conditions
(see IEC 62368-1, clause B.4)
with any conductor of RFT-V circuit that normally
connects to ICT network being earthed (V) ........ :
without any conductor of RFT-V circuit that normally
connects to ICT network being earthed (V) ....... :
Not exceeding Figure 2 limits during first 200 ms, N/A
load circuits disconnected
Not exceeding 6.3.1.2.1 limits after first 200 ms N/A
6.3.1.2.3 Voltage limits with one RFT-V conductor earthed, N/A
between the other conductor and earth:
Not exceeding maximum RFT-V circuit supply N/A
voltage after 200 ms (V) ...................................... :
For RFT-V circuits with normal open circuit voltage N/A
exceeding 140 V DC, current between the other
conductor and earth not exceeding Figure 1 line-to-
resistor, under any external load condition ......... :
This current not exceeding 10 mA DC after 10 s : N/A
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
181 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 82 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.3.2 Accessibility to electrical energy sources and N/A
safeguards (See also IEC 62368-1, 5.3.2)
6.3.2.1 Accessibility for an ordinary person N/A
Adequate protection against contact with RFT circuits N/A
bare parts for all positions of the equipment wired and
operated as in normal use.
Not accessible: bare parts at ES3; and an ES3 basic N/A
safeguard
Not accessible: bare parts at ES2, except for pins of N/A
connectors. However, such pins are not accessible
under normal operating conditions by IEC 62368-1,
Figure V.3 blunt probe
Protection achieved by insulation, guarding See appended table 4.1.2 N/A
(electrical enclosure), interlocks :
6.3.2.2 Accessibility for an instructed person N/A
(See also IEC 62368-1, clause 4.3.3)
Contact is possible with RFT circuit bare parts by the N/A
IEC 62368-1, Figure V.3 blunt probe
RFT circuit bare parts so located or guarded that N/A
unintentional contact is unlikely.
6.3.2.3 Accessibility for a skilled person N/A
(See also IEC 62368-1, clause 4.3.4 and 5.3)
RFT circuits bare parts located or guarded so that N/A
accidental shorting to ES1 or ES2 parts is unlikely
Required guards easily removable and replaceable if N/A
necessary for servicing.
6.3.3 Safeguards N/A
6.3.3.1 RFT circuits separated from other circuits and parts N/A
.............................................................................. :
- from other RFT circuits by functional insulation. N/A
If shorted, neither circuit exceeds 6.3.1.1 and
6.3.1.2 limits
- from other RFT circuits separated as if one was N/A
at ES3
- from earthed accessible parts, earthed ES1 N/A
circuits and earthed ES2 circuits by basic
insulation
- from unearthed accessible parts, ES1, ES2 and N/A
ES3 circuits by one or both:
double insulation or reinforced insulation;
basic insulation, together with a conductive
screen as protective bonding conductor.
6.3.3.2 Interconnection of equipment N/A
6.3.3.2.1 General requirements .......................................... : N/A
Interconnecting cable containing more than one type N/A
of circuit ................................................................ :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
182 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 83 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.3.3.2.2 Interconnection between RFT circuits N/A
RFT-C circuits in supply equipment are connected to N/A
RFT-C circuits in other equipment ..................... :
RFT-V circuits in supply equipment are connected to N/A
RFT-V circuits in other equipment ..................... :
6.3.4 Installation instructions for equipment using an RFT N/A
circuit do specify:
6.3.4 a) RFT circuit voltage (V) ......................................... : N/A
6.3.4 b) EUT effective capacitance between connection points N/A
1) for the ICT network conductors (nF) ............... :
2) for ICT network one conductor and earth (nF) :
6.3.4 c) A system assessment shall be carried out at the time N/A
of installation, to ensure:
Effective capacitance of the total system, including N/A
the capacitance of the EUT, does not exceed the
values specified in Figure 3 ................................ :
6.3.4 d) Checking is done that the voltage rating of ICT N/A
network wiring is adequate for normal RFT circuit
voltage, together with superimposed transients . :
6.3.4 e) Checking is done that circuits to be connected N/A
together are either all RFT-C circuits or all RFT-V
circuits .................................................................. :
6.3.4 f) Where an RFT circuit is directly connected to an ICT N/A
network, that the building cabling termination records
are updated to indicate which terminals are used for
an RFT circuit....................................................... :
6.4 Electrically caused fire N/A
6.4.1 Classification of RFT power sources N/A
6.4.1.1 RFT-C power source is a PS2 circuit N/A
(See IEC 62368-1, clause 6.2.2.5 or 6.2.2.6) ..... :
RFT-C circuit limited by maximum current (60 mA) N/A
and maximum voltage (usually < 800 V).
RFT-C circuits comply with requirements of 6.4.2. N/A
6.4.1.2 RFT-V power source is a PS2 circuit N/A
(See IEC 62368-1, clause 6.2.2.5)...................... :
RFT-V circuits comply with requirements of 6.4.2. N/A
6.4.2 Fire protection requirements N/A
RFT circuit power in accordance with Table 1.... : N/A
Output voltage (V) ................................................ :
Maximum current (A) ........................................ :
Maximum Power (W) .......................................... :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
183 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 84 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Steady state current that can be supplied to ICT N/A
network complies with
IEC 62368-1:2014, 6.5.3
IEC 62368-1:2018, 6.5.2 ................................... :
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
184 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 85 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.1 Table: Power transfer using ES1 or ES2 voltages. General requirements P
Output Components Output voltage V dc)
Connector
No load Normal load Max. rated road Limits
USB output USB output + / - 4.94V 4.94V 4.94V 6V
(5.0V)
USB output USB output + / - 8.95V 8.95V 8.94V 20V
(9.0V)
USB output USB output + / - 11.95V 11.95V 11.94V 20V
(12.0V)
Supplementary Information:
5.3.2 TABLE: DC power transfer interconnection to other equipment P
Note: Measured each port with maximum attainable current:
Output Components Fault current Any circumstance (A) More than 5 s (A)
Circuit rating (A)
Meas. Limit Meas. Limit
USB output USB output + / - -- 3.64 8 3.64 3.9
(5VDC,3A) Normal
USB output USB output + / - -- 0 8 0 3.9
C6 SC
USB output USB output + / - -- 2.45 8 2.45 3.0
(9VDC,2A) Normal
USB output USB output + / - -- 0 8 0 3.0
(9VDC,2A) C6 SC
USB output USB output + / - -- 1.83 8 1.83 2.25
(12VDC,1.5 Normal
A)
USB output USB output + / - -- 0 8 0 2.25
(12VDC,1.5 C6 SC
A)
Supplementary Information: Fau
Fault conditions tested: SC=Short circuit, OC=Open circuit
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
185 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 86 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.1 TABLE: Requirement for the PSE P
Note: Measured U fault (V) with all load circuits disconnected:
Output Components U nominal U fault (V) Fault conditions tested
Circuit rated (V)
Meas. Limit --
USB output USB output + / - 5.0 4.94 7.5 --
(5.0V)
Normal
USB output USB output + / - 5.0 0 7.5 --
(5.0V)
C6 SC
USB output USB output + / - 9.0 8.95 20 --
(9.0V)
Normal
USB output USB output + / - 9.0 0 20 --
(9.0V)
C6 SC
USB output USB output + / - 12.0 11.85 20 --
(12.0V)
Normal
USB output USB output + / - 12.0 0 20 --
(12.0V)
C6 SC
Supplementary Information:
Fault conditions tested: SC=Short circuit, OC=Open circuit
5.4.2 TABLE: Requirement for the PD N/A
Note: Measured U input at PSE with all other load circuits disconnected:
Input Components U nominal U input (V) Observation
Circuit rated (V)
Meas. Limit Component Hazard
-- -- -- -- -- -- --
-- -- -- -- -- -- --
Supplementary Information: Conditions tested: PD supplied with voltage above nominal rated input voltage.
Nominal > 5 V, supplied with 130% (min. 7.5 V)
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
186 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 87 of 96 Report No. ARLI-ESH-P22071902
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.3.1.1 TABLE: RFT-C circuit limits N/A
Parameters
Location
Supply
No. (e.g. circuit Test conditions U I Observation
Voltage
designation) limit
(V DC) (mA DC)
1 Normal load -- -- 60 mA
Abnormal load -- -- 60 mA
To earth -- -- 2 mA --
Single fault -- -- 60 mA
Single fault to earth -- -- 25 mA
2 Normal load -- -- 60 mA
Abnormal load -- -- 60 mA
To earth -- -- 2 mA --
Single fault -- -- 60 mA
Single fault to earth -- -- 25 mA
Supplementary information:
1) Current flow from the RFT-C CIRCUIT supply equipment into the TELECOMMUNICATION NETWORK
2) Current flow from one conductor of the RFT-C CIRCUIT supply equipment through the
TELECOMMUNICATION NETWORK to earth
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
187 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 88 of 96 Report No. ARLI-ESH-P22071902
Attachment 3: Picture of EUT
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
188 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 89 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
189 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 90 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
190 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 91 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
191 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 92 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
192 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 93 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
193 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 94 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
194 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 95 of 96 Report No. ARLI-ESH-P22071902
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
195 TEST REPORTS FOR 5 722 29A WHICH IS THE SAME OFFERED MATERIAL 5 721 62 A
Page 96 of 96 Report No. ARLI-ESH-P22071902
Representative Model
The Accreditation only attests the technical capability of the testing laboratory for the tests covered by the accreditation.
TEST REPORT IEC EN 62368-1 VER 1.5
1 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
2 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
3 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
4 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Test Report issued under the responsibility of:
TEST REPORT
IEC 60884-2-3
Plugs and socket-outlets for household and similar purposes
Part 2-3: Particular requirements for switched socket-outlets without
interlock for fixed installations
Report Reference No. ..................... : 220300360SHA-001
Date of issue ................................... : 2022-04-21
Total number of pages .................... 102
CB Testing Laboratory ................... : Intertek Testing Services Shanghai.
Address ......................................... : Building No.86, 1198 Qinzhou Road (North), Shanghai 200233,
China
............................ : Legrand Intelligent Electrical (Huizhou) Co.,Ltd.
Address ...........................................: Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK Hi-tech
Industrical Development Zone, Huizhou, Guangdong, China
Test specification:
Standard ..........................................: IEC 60884-2-3:2006 with IEC 60884-1:2002, AMD1:2006,
AMD2:2013
Test procedure ............................... : CB Scheme
Non- N/A
Test Report Form No. .....................: IEC60884_2_3C
Test Report Form(s) Originator..... : IMQ S.p.A.
Master TRF ...................................... : Dated 2017-10-31
Copyright © 2017 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
5 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 2 of 102 Report No.: 220300360HA-001
Test item description..................... : Switched socket outlet, flush type
Trade Mark ...................................... : legrand, tenby (alternative), see page 8 for details
Manufacturer .................................. : LEGRAND FRANCE
128, Avenue du Maréchal de Lattre de Tassigny 87045 LIMOGES
Cedex-FRANCE
Model/Type reference .................... : 617*44,28**36,832*79,833*79, 282443***, K8/15/13/U2***-HK,
57****, 730079,738143, 281136**, 838143, 618044
Ratings ............................................ : 13A 250V~, IP20, Class I
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
CB Testing Laboratory: Intertek Testing Services Shanghai.
Testing location/ address.............................: Building No.86, 1198 Qinzhou Road (North), Shanghai
200233, China
Tested by (name, function, signature) ........: Klaus Liu (Engineer)
Approved by (name, function, signature)...: Justin Zhang
(Mandated Reviewer)
Testing procedure: CTF Stage 1:
Testing location/ address.............................:
Tested by (name, function, signature) ........:
Approved by (name, function, signature)...:
Testing procedure: CTF Stage 2:
Testing location/ address.............................:
Tested by (name + signature) ......................:
Witnessed by (name, function, signature) .:
Approved by (name, function, signature)...:
Testing procedure: CTF Stage 3:
Testing procedure: CTF Stage 4:
Testing location/ address.............................:
Tested by (name, function, signature) ........:
Witnessed by (name, function, signature) .:
Approved by (name, function, signature)...:
Supervised by (name, function, signature) :
TRF No. IEC60884_2_3C
6 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 3 of 102 Report No.: 220300360HA-001
List of Attachments (including a total number of pages in each attachment):
Photos (from page 53 to page 102), total 50 pages
Summary of testing:
The products mentioned in test report complies with IEC 60884-2-3:2006 (Second Edition) with
IEC 60884-1:2002 (Third Edition) + A1:2006 + A2:2013.
We conclude that the products described in this test report comply with the standard according to the
testing results on the submitted samples.
Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement
uncertainty.
The results of tests are based on CB report 201201700SHA-001, which issued by Intertek Testing
Services Shanghai, on 2021-04-16 and clauses 8 ,13, 24.1 & 24.16 of IEC 60884-2-3 need re-evaluated
due to the following updating:
1. Add new models: 838143 & 618044
2. Add factory information: Legrand Electric Ltd
Unit 12 No.1 Industrial Estate Medomsley Road, Consett County
Durham, DH8 6SR United Kingdom
Tests performed (name of test and test Testing location:
clause):
Intertek Testing Services Shanghai.
All clauses of IEC 60884-2-3:2006 (Second Edition)
Building No.86, 1198 Qinzhou Road (North),
in conjunction with IEC 60884-1:2002 (Third Shanghai 200233, China
Edition) + A1:2006 + A2:2013.
Summary of compliance with National Differences
N/A
TRF No. IEC60884_2_3C
7 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 4 of 102 Report No.: 220300360HA-001
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
Model 838143 as an example
TRF No. IEC60884_2_3C
8 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 5 of 102 Report No.: 220300360SHA-001
Test item particulars .................................................. :
Standard Sheet .......................................................... : Type G (configuration of BS 1363-2)
Rated current (A) / Rated voltage (V) ..................... : 13 / 250
Degree of protection against access to hazardous IP2X
parts and against harmful ingress of solid foreign
objects ........................................................................ :
Degree of protection against harmful ingress of IPX0
water ........................................................................... :
Provision for earthing ............................................... : with earthing contact
Method of connecting the cable ............................. : rewirable
Type of cable ............................................................. : N/A
Nominal cross-sectional areas (mm2) ................... : N/A
Type of terminals ...................................................... : screw-type
Type of connections ................................................. : Riveted for earthing part
Socket-outlets:
Degree of protection against electric shock ......... : normal protection
Existence of shutters ................................................ : with shutters
Method of application / mounting of the socket- flush-type
outlet ........................................................................... :
Method of installation ............................................... : Design A/Design B
Intended for circuits where ...................................... : a single earthing circuit provides protective earthing
Switched socket-outlets without interlock:
According to the method of actuating the switch : rocker
According to the switching of the neutral ............. : Switched neutral / unswitched neutral
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ......................................... : 2022-03-02
Date (s) of performance of tests ............................... : 2022-03-02 to 2022-03-28
TRF No. IEC60884_2_3C
9 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 6 of 102 Report No.: 220300360SHA-001
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement,
for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit
copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its
marks for the sale or advertisement of the tested material, product or service must first be approved in writing
by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by
itself does not imply that the material, product, or service is or has ever been under an Intertek certification
program.
aration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a
Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Factory 1: Legrand Electric Ltd
Unit 12 No.1 Industrial Estate Medomsley Road,
Consett County Durham, DH8 6SR United Kingdom
Factory 2: Legrand Intelligent Electrical (Huizhou)
Co., Ltd.
Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK
Hi-tech Industrial Development Zone, Huizhou,
Guangdong, China
TRF No. IEC60884_2_3C
10 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 7 of 102 Report No.: 220300360SHA-001
General product information:
13A 250V~, flush type, IP20, Class I, rewirable, two way Type G outlets (configuration of BS 1363-2),
with shutters, with single pole switch, with USB charger which evaluated according to IEC 62368-1: 2018
which in conjunction with standard IEC 62368-3:2017 with report no 200302028SHA-001 and
200302028SHA-002, with metal cover, with plastic cover plate or plastic lining combined with metal sheet
cover plate, with or without metal frame, design A or design B construction, see below for details:
617*44 617144 design A construction, white colour
617344 with plastic cover with dark grey colour
arc transition chamfer,
617444 brown colour
with front cover
without embossing
pattern, with
617644 design A construction, white colour
617744 with plastic cover with anthracite colour
angle chamfer, with
617844 ivory colour
front cover with
embossing pattern,
with trademark
28**36 281136 design A construction, white colour
283136 plastic cover, with silver colour
283336 pearl colour
283536 dark silver colour
283936 champagne colour
282136 matt black colour
832*79 832079 design A construction, flat BSS color
832279 metal cover, with flat PSS color
832479 flat gold color
833*79 833079 design B construction, Trad BSS color
833279 metal cover, with Trad PSS color
833479 Trad Gold color
282443*** 282443 design A construction, White colour
282443-C plastic cover, with Matt black colour
282443-C1 Rose gold colour
282443-C2 CHAMPAGNE colour
282443-C3 DARK SILVER colour
TRF No. IEC60884_2_3C
11 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 8 of 102 Report No.: 220300360SHA-001
K8/15/13/U2***-HK K8/15/13/U2-HK design A construction, White colour
K8/15/13/U2-C-HK plastic cover, with Matt black colour
K8/15/13/U2-C1-HK Rose gold colour
K8/15/13/U2-C2-HK Champagne colour
K8/15/13/U2-C3-HK Dark silver colour
K8/15/13/U2-C4-HK Pink colour
57**** 572142 design A construction, White colour
572642 without cover, with Magnesium colour
570081 Soft ALU colour
571081 Champagne colour
281136** 281136MW design A construction, matt white colour
281136MB plastic cover, metal matt black colour
frame, with trademark
281136MG matt grey colour
281136CH champagne colour
281136DB dark bronze colour
281136DS dark silver colour
281136BA design A construction, brushed aluminium colour
plastic lining combined
281136BB brushed black colour
with metal sheet cover
plate, metal frame,
with trademark
730079: design B construction, plastic cover,
For 282443*** series and K8/15/13/U2***-HK series, they with total same construction, only different
type designation acc
For 57**** series, all test evaluated when with mated plastic cover or metal cover which provided by
the manufacturer as far as possible.
618044: same as 617144 except with different shape cover plate, with trademark legrand
838143: same as 617144 except with different shape cover plate, with trademark legrand &
TRF No. IEC60884_2_3C
12 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 9 of 102 Report No.: 220300360SHA-001
For model: 617*44, 28**36, 832*79, 833*79, 282443***, K8/15/13/U2***-HK, 57****, 730079, 738143,
838143 & 618044
Table of critical components and materials:
Object / Part No. Manufacturer / Type / Model Technical data Standard Mark(s) of
Trademark conformity
Cover plate (for
type 617*44,
838143, 618044,
Test with
28**36, Covestro PC, minimum IEC 60884-2-3
Makrolon PC
thickness 1,0mm appliance
282443***,
K8/15/13/U2***-
HK series)
Cover plate (for
Test with
type Covestro PC, minimum IEC 60884-2-3
Makrolon PC
thickness 1,0mm appliance
575117)
PC, minimum
Plastic frame for
thickness 1,5mm, Test with
cover 575117 Covestro FR6005+(z) IEC 60884-2-3
with UL file UL appliance
and 575118
E41613
Front cover (for
type 617*44,
838143, 618044,
28**36, Test with
Covestro PC, minimum IEC 60884-2-3
Makrolon PC
282443***, thickness 1,5mm appliance
K8/15/13/U2***-
HK series and
572142,572642)
Front cover (for
Liyang Josen UREA, minimum Test with
type 738143, L110B IEC 60884-2-3
Plastic Co.,Ltd. thickness 1,0mm appliance
730079)
PC, minimum
Front plastic
thickness 1,5mm, Test with
frame (for type Covestro FR6005+(z) IEC 60884-2-3
with UL file UL appliance
833*79 series)
E41613
PC, minimum
Back plastic
thickness 1,5mm, Test with
frame (for type Covestro FR6005+(z) IEC 60884-2-3
with UL file UL appliance
832*79 series)
E41613
TRF No. IEC60884_2_3C
13 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 10 of 102 Report No.: 220300360SHA-001
Object / Part No. Manufacturer / Type / Model Technical data Standard Mark(s) of
Trademark conformity
Front metal plate stainless steel,
Test with
(for type 833*** & Legrand UK 304 minimum IEC 60884-2-3
appliance
832*** series) thickness 1,0mm
PC, minimum Test with
Switch rocker Covestro Makrolon PC IEC 60884-2-3
thickness 1,0mm appliance
PP, minimum
SHANGHAI
thickness Test with
Base SUNNY NEW HFP1010-R IEC 60884-2-3
1,5mm,with UL appliance
TECHNOLOGY
file E200750
PA6 material,
PA6-G30 Test with
Shutter body Kingfa. minimum IEC 60884-2-3
AWBK036 appliance
thickness 1,5mm
PC material,
Test with
Shutter box Mitsubishi RX2123 minimum IEC 60884-2-3
appliance
thickness 1.5mm
Intertek
Input report
Legrand IEC 62368-1
220~250V~, 50- 200302028S
Intelligent
PYS-16S- 60Hz Max 0,3A, HA-001
USB Charger Electrical
050310 Output 5.0Vdc Intertek
(Huizhou)
3.0A 15.0W (in report
Co.,Ltd. 200302028S
total) IEC 62368-3
HA-002
TRF No. IEC60884_2_3C
14 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 11 of 102 Report No.: 220300360SHA-001
For model 281136** series:
Table of critical components and materials
Manufacturer / Mark(s) of
Object / Part No. Type / Model Technical data Standard
Trademark conformity
Cover plate / Test with
Covestro (BAYER) - PC IEC 60884-2-3
rocker shell appliance
Cover plate /
SABIC Innovative Test with
rocker shell - PC IEC 60884-2-3
Plastics appliance
alternative 1
Cover plate /
Test with
rocker shell Taisu Plastification - PC IEC 60884-2-3
appliance
alternative 2
Cover plate /
Test with
rocker shell Kingfa - PC IEC 60884-2-3
appliance
alternative 3
IEC 60884-2-3 Test with
Rocker MEP - PC
appliance
Rocker IEC 60884-2-3 Test with
Covestro - PC
alternative 1 appliance
IEC 60884-2-3 Test with
Front cover Covestro (BAYER) PC T044
appliance
Test with
Base Silver age - PP IEC 60884-2-3
appliance
Base alternative IEC 60884-2-3 Test with
Taisu Plastification - PP
1 appliance
Test with
Shutter body Wen An Tai De - PA IEC 60884-2-3
appliance
Shutter body IEC 60884-2-3 Test with
Taisu Plastification - PA
alternative 1 appliance
IEC 60884-2-3 Test with
Shutter box Covestro - PC
appliance
Intertek
report
Input IEC 62368-1
220~250V~, 50- 200302028S
Legrand Intelligent HA-001
PYS-16S- 60Hz Max 0,3A,
USB Charger Electrical Intertek
050310 Output 5.0Vdc
(Huizhou) Co.,Ltd.
3.0A 15.0W (in report
total)
IEC 62368-3 200302028S
HA-002
TRF No. IEC60884_2_3C
15 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 12 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
8 MARKING P
8.1 Accessories marked as follows: P
- rated current (A) ....................................................: 13A P
- rated voltage (V) ....................................................: 250V P
- symbol for nature of supply ..................................: ~ P
- .....: See page 1 P
- type reference .......................................................: See page 1 P
- symbol for degree of protection (first digit) ...........: IP2X N/A
- symbol for degree of protection (second digit) .....: IPX0 N/A
Socket-outlets with screwless terminals marked with the following: N/A
- the length of insulation to be removed .................: N/A
- an indication of the suitability to accept rigid N/A
conductors only (if any) ...........................................:
Switched socket-outlets without interlock: P
Symbol of mini-gap construction N/A
Symbol OFF position N/A
Symbol ON position For type with plastic rocker P
8.2 Symbols used: as required in the standard P
Marking for the nature of supply placed next to the P
marking for rated current and rated voltage
8.3 Marking of fixed socket-outlets placed on the main part: P
- rated current, rated voltage and nature of supply P
- identification mark of the manufacturer or of the P
responsible vendor
- length of insulation to be removed, if any See page 4 P
- type reference P
Cover plates necessary for safety purposes and N/A
intended to be sold separately: marked with the
type reference
IP code, if applicable: marked so as to be easily N/A
discernible
Fixed socket-outlets classified according to item b) of N/A
7.2.5: identified by a triangle visible after installation
unless they have an interface configuration different
from that used in normal circuits .............................:
8.4 Plugs and portable socket-outlets: marking
specified in 8.1, other than the type reference,
easily discernible N/A
TRF No. IEC60884_2_3C
16 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 13 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Plugs and portable socket-outlets for equipment of N/A
class II not marked with the symbol for class II
construction
8.5 Neutral terminals: N ................................................: N P
Earthing terminals: [earth symbol] ..........................: P
Markings not placed on screws or other easily P
removable parts
Terminals for conductors not forming part of the main function of the socket-outlet: N/A
- clearly identified unless their purpose is self- N/A
evident, or
- indicated in a wiring diagram fixed to the accessory N/A
Identification of such terminals may be achieved by: N/A
- their being marked with graphical symbols N/A
according to IEC 60417-2 or colours and/or
alphanumeric system, or
- their being marked with their physical dimensions N/A
or relative location
8.6 Surface-type mounting boxes forming an integral N/A
part of socket-outlets having IP>20: IP code marked
on the outside of its associated enclosure so as to
be easily discernible
8.7 Indication of which position or with which special N/A
provision the declared IP of flush-type and semi-
flush-type fixed socket-outlets having IP>X0 is
ensured
8.8 Marking durable and easily legible. Test: 15 s with P
water and 15 s with petroleum spirit
8.101 Terminals for phase conductors (supply P
conductors): identified unless method of connection
is of no importance, self-evident or indicated on a
wiring diagram
Such identification may take the form of a letter L or P
for more than one pole L1, L2, L3, etc., which may
be accompanied by arrow or arrows pointing to the
relevant terminal or terminals.
Indications not placed on screws or other easily P
removable parts
8.102 Two, three, and four pole switches and switches N/A
having a rated voltage exceeding 250 V or a rated
current exceeding 16 A shall be so marked that the
direction of movement of the actuating member to is
different positions or the actual switch position, is
clearly indicated.
Marking clearly visible on the front of the switch N/A
TRF No. IEC60884_2_3C
17 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 14 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Not possible to fix cover, cover plate, or removable N/A
actuating members in an incorrect position
For the indication of the direction of movement of the N/A
operating means, symbols may be used
Closed position (on) shall be clearly indicated N/A
9 CHECKING OF DIMENSIONS P
9.1 Accessories and surface-type mounting boxes P
comply with the appropriate standard sheets and
corresponding gauges, if any
Insertion of plugs into fixed or portable socket- P
outlets ensured by their compliance with the
relevant standard sheets
Compliance checked by measurement and by P
means of gauges with manufacturing tolerances as
shown in table 2
9.2 It is not possible to engage a plug with: P
- a socket-outlet having a higher voltage rating or P
a lower current rating;
- a socket-outlet with a different number of live P
poles (exception admitted provided that no
dangerous situation can arise);
- a socket-outlet with earthing contact (plug for P
class 0 equipment).
Engagement of a plug for class 0 or class I N/A
equipment with a socket-outlet designed to
accept plugs for class II equipment, not possible
Impossibility of insertion checked by applying a gauge, for 1 min, with a force P
of:
- 150 N (rated current 16A); P
- 250 N (rated current 16A) N/A
Accessories with electrometric or thermoplastic P
material: test carried out at (35 2) °C
9.3 Deviations from standard sheets made only if N/A
they provide technical advantage and do not
affect the purpose and safety of accessories
complying with standard sheet
10 PROTECTION AGAINST ELECTRIC SHOCK P
10.1 Socket-outlets: live parts not accessible P
TRF No. IEC60884_2_3C
18 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 15 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Live parts of plugs: not accessible when the plug N/A
is in partial or complete engagement with a
socket-outlet
Test with test probe B of IEC 61032 P
Accessories with electrometric or thermoplastic P
material: additional test carried out at (35 2) °C For type with plastic cover
with test probe 11 of IEC 61032 (75 N for 1 min) plate
During the test: accessories not deform and no P
live parts accessible
Plugs and portable socket-outlets pressed with a N/A
force of 150 N for 5 min as shown in figure 8:
specimens not show deformation
10.2 Accessible parts (with exception of small screws P
and the like for fixing bases and covers or cover
plates): made of insulating material
Cover or cover plates of fixed socket-outlets and P
accessible parts of plugs and portable socket-
outlets: made of metal if the requirements of
10.2.1 or 10.2.2 are fulfilled
10.2.1 Metal covers or cover plates protected by For type with plastic lining P
supplementary insulation made by insulating combined with metal sheet
linings or insulating barriers cover
Insulating linings or insulating barriers cannot be P
removed without being permanently damaged
Insulating linings or insulating barriers cannot be P
replaced in an incorrect position and, if they are
omitted, accessories are rendered inoperable or
manifestly incomplete
There is no risk of accidental contact between P
live parts and metal covers or cover plates
10.2.2 Metal covers or cover plates automatically P
connected, through a low-resistance connection,
to the earth during fixing For type with metal cover
10.3 Contact between a pin of a plug and a live P
socket-contact of a socket-outlet not possible
while any other pin is accessible
Compliance checked by manual test and by P
means of gauges with tolerances as specified in
table 2
Accessories with electrometric or thermoplastic P
material: test carried out at (35 2) °C
TRF No. IEC60884_2_3C
19 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 16 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Socket-outlets with enclosure or bodies of rubber N/A
or polyvinyl chloride: test carried out with a
force of 75 N for 1 min
Fixed socket-outlets provided with metal covers N/A
or cover plates: clearance of at least 2 mm
required between a pin and a socket-contact
when another pin(s) is(are) in contact with the
metal covers or cover plates (mm) ......................:
10.4 External parts of plugs made of insulating N/A
material
Overall dimensions of rings around pins not N/A
exceed 8 mm concentric with respect to the pin
10.5 Shuttered socket-outlets: live parts not P
accessible, without a plug in engagement, with
the gauges shown in figure 9 and 10
Live contacts automatically screened when the P
plug is withdrawn
Means cannot easily be operated by anything P
other than a plug and not depend upon parts
which are liable to be lost
Gauge of figure 9, applied to the entry holes P
corresponding to live contacts with a force of
20 N, for approximately 5 s, successively in
three directions, does not touch live parts
Steel gauge of figure 10, applied to the entry P
holes corresponding to live contacts with a force
of 1 N for approximately 5 s, in three directions,
does not touch live parts
Accessories with electrometric or thermoplastic P
material: test carried out at (35 2) °C
10.6 Earthing contacts of a socket-outlet designed that N/A
they cannot be deformed by the insertion of a
plug without side earthing contact
Test plug inserted into the socket-outlet with a force of 150 N for 1 min N/A
10.6 Earthing contacts of a socket-outlet designed that N/A
they cannot be deformed by the insertion of a
plug
After this test: socket-outlet still comply with the N/A
requirements of clause 9
10.7 Socket-outlet with increased protection: live parts N/A
not accessible
TRF No. IEC60884_2_3C
20 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 17 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Test wire of 1 mm diameter (figure 10) applied with a N/A
force of 1 N on all accessible surfaces does not
touch live parts
Accessories with electrometric or thermoplastic N/A
material: test carried out at (35 2) °C
10.101 Knobs, operating levers, push buttons, rockers and P
the like: of insulating material, unless: For type with plastic rocker
- accessible metal parts separated from metal parts P
of mechanism by double or reinforced insulation, or For type with metal rocker
- reliably connected to earth N/A
10.102 Metal parts of the switch mechanism, which are N/A
not insulated from live parts, shall not protrude
from the enclosure.
10.103 Metal parts of the switch mechanism, shall not N/A
be accessible when the switched socket-outlet
with interlock is mounted as for normal use.
In addition, these metal parts shall be insulated N/A
from accessible metal parts.
This additional requirement does not apply if the N/A
metal parts of the mechanism are separated from
live parts or
If they are reliably connected to earth. N/A
11 PROVISION FOR EARTHING P
11.1 Earth connection made before the current- P
carrying contacts of the plug become live
Current-carrying pins are separated before the P
earth connection is broken
11.2 Earthing terminals of rewirable accessories comply P
with clause 12
Earthing terminals of the same size as the P
corresponding terminals for the supply conductors
Earthing terminals of rewirable accessories: internal P
Additional external earthing terminal of fixed socket- N/A
outlets of size suitable for conductors of at least 6
mm2 ......................................................................... :
Earthing terminals of fixed socket-outlets: fixed to the P
base or to a part reliably fixed to the base
Earthing contacts of fixed socket-outlets: P
- fixed to the base, or P
TRF No. IEC60884_2_3C
21 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 18 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- fixed to the cover (reliably connected to the N/A
earthing terminals; contact pieces silver plated or
with adequate protection)
Parts of earthing circuit in one piece or reliably P
connected by riveting, welding, or the like In one piece
11.3 Accessible metal parts of fixed socket-outlets: N/A
permanently and reliably connected to the earthing
terminal
11.4 Socket-outlets, having an IP>X0, with enclosure of insulating material and more N/A
than one cable inlet, provided with:
- an internal fixed earthing terminal, or N/A
- adequate space for a floating terminal (test N/A
connection using the type of terminal specified by
the manufacturer), unless
- earthing terminal of socket-outlet itself allows the N/A
connection of an incoming and an outgoing earthing
conductor
11.5 Connection between earthing terminal and For type with metal cover P
accessible metal parts: of low resistance
Test current equal to 1,5 times the rated current or 25A
25 A (A) ................................................................... :
Resistance not exceed 0,05 ( ) ........................ : Max. P
11.6 Fixed socket-outlets according to item b) of 7.2.5: N/A
earthing socket contact and its terminal
electrically separated from any metal mounting
means or other exposed conductive parts which
may be connected to the protective earthing
circuit of the installation
12 TERMINALS AND TERMINATIONS P
All the test on terminals, with the exception of P
the tests of 12.3 11 and 12.3.12, made after the
test of clause 16
12.1 General P
12.1.1 Rewirable fixed socket-outlets provided with P
screw-type terminals or with screwless terminals
................................................................................. : Screw-type
Rewirable plugs and portable socket-outlets N/A
provided with terminals with screw clamping . :
Pre-soldered flexible conductors used: pre- N/A
soldered area outside the clamp area of screw-
type terminals
TRF No. IEC60884_2_3C
22 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 19 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Clamping means of terminals: not serve to fix P
any other components
12.1.2 Non-rewirable accessories provided with N/A
soldered, welded, crimped or equally effective
permanent connections (termination) ............... :
Screwed or snap-on connections not used N/A
Connections made by crimping a pre-soldered N/A
flexible conductor not permitted
12.2 Terminals with screw clamping for external copper conductors P
12.2.1 Accessories provided with terminals which P
allows the proper connection of copper
conductors as shows in table 3
Rated current (A); Type of accessories .............. : 13A; 2P+E
Type of conductor (rigid / flexible) ..................... : rigid
Smallest / largest cross-sectional area (mm2) .. : 1,5/3X2,5/2X4,0
Diameter of the largest conductor (mm) ........... : 2,72
Figure of terminal ................................................. : 2
Minimum diameter D (minimum dimensions) of P
conductor space: required (mm); measured (mm) Required: 3,6
................................................................................. : Measured: 4,4
12.2.2 Terminals allow the conductor to be connected P
without special preparation
12.2.3 Terminals have adequate mechanical strength P
Screws and nut for clamping the conductors P
have metric ISO thread or a comparable thread
Screws not of soft metal such as zinc or P
aluminium
12.2.4 Terminals resistant to corrosion P
12.2.5 Terminals clamp the conductor(s) without undue P
damage See appended table 12.2.5
During the test: conductor not slip out, no break P
near clamping unit and no damage
12.2.6 Terminals clamp the conductor reliably between P
metal surfaces See appended table 12.2.6
During the test: conductor not move noticeably P
12.2.7 Terminals designed or placed that the conductor P
cannot slip out while the clamping screws or
nuts are tightened See appended table 12.2.7
TRF No. IEC60884_2_3C
23 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 20 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
After the test: no wire of the conductor escaped P
from the clamping unit
12.2.8 Terminals not work loose from their fixing to P
accessories
Torque test (screws and nuts tightened and loosened 5 times): P
- rated current (A) ................................................. : 13A
- copper conductor of the largest cross-sectional
area (mm²) (table 3) ............................................. : 3X2,5 and 2X4,0
- type of conductor (solid or stranded) .............. : Solid
- torque (Nm) (table 6 or appropriate figures 2, 3
or 4) ........................................................................ : 0,8
During the test: terminals not work loose and P
show no damage
12.2.9 Clamping screws or nuts of earthing terminals: P
adequately locked against accidental loosening,
not possible to loosen them without the aid of a
tool
12.2.10 Earthing terminals: no risk of corrosion P
Body of brass or other metal no less resistant to P
corrosion
The body is a part of a frame or enclosure of N/A
aluminium alloy: precautions are taken to avoid
the risk of corrosion
12.2.11 Pillar terminals: distance no less than the value P
specified in figure 2: required (mm); measured Required: 1,5
(mm) ....................................................................... : Measured: >2
Mantle terminals: distance no less than the N/A
value specified in figure 5: required (mm);
measured (mm) .................................................... :
12.3 Screwless terminals for external copper conductors N/A
12.3.1 Screwless terminals of the type suitable for: N/A
- for rigid copper conductors only, or N/A
- for both rigid and flexible copper conductors N/A
(tests carried out with rigid and then repeated
with flexible conductors)
12.3.2 Screwless terminals provided with two clamping N/A
units each allowing the proper connection of
rigid or of rigid and flexible conductors having
nominal cross-sectional areas from 1,5 up to 2,5
mm 2 (table 7)
TRF No. IEC60884_2_3C
24 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 21 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Two conductors to be connected: each conductor N/A
introduced in a separate clamping unit
12.3.3 Screwless terminals allow the conductor to be N/A
connected without special preparation
12.3.4 Parts of screwless terminals intended for N/A
carrying current of materials as specified in 26.5
12.3.5 Screwless terminals clamp specified conductors N/A
with sufficient contact pressure without undue
damage to the conductor
Conductor clamped between metal surfaces N/A
12.3.6 It is clear how the connection and disconnection N/A
of the conductors is to be made
Disconnection of a conductor require an N/A
operation, other than a pull, so that can be made
manually with or without a general-purpose tool
It is not possible to confuse the opening intended N/A
for the use of a tool with the opening intended
for the conductor
12.3.7 Screwless terminals intended for the interconnection of two or more N/A
conductors:
- during insertion, operation of clamping means N/A
of one of the conductors is independent of
operation of that for the other conductor(s);
- during disconnection, conductors can be N/A
disconnected either at the same time or
separately;
- each conductor introduced in a separate N/A
clamping unit.
- it is possible to clamp securely any number of N/A
conductors up to the maximum as designed.
Number of conductors; Nominal cross-sectional
area (mm2) ............................................................. :
12.3.8 Screwless terminals of fixed socket-outlets: N/A
adequate insertion obvious and over-insertion
prevented
12.3.9 Screwless terminals properly fixed to the socket- N/A
outlets
Not work loose when conductors are connected N/A
or disconnected
Self-hardening resins used to fix terminals not N/A
subject to mechanical stress
TRF No. IEC60884_2_3C
25 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 22 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
12.3.10 Screwless terminals withstand mechanical N/A
stresses occurring in normal use See appended table 12.3.10
During application of the pull conductor not N/A
come out of the terminal
Additional test with apparatus shown in figure N/A
See appended table 12.3.10
11
During the test: conductors not moved noticeably N/A
in the clamping unit
After these tests: neither terminals nor clamping N/A
means have worked loose and conductors show
no deterioration
12.3.11 Screwless terminals withstand electrical and N/A
thermal stresses occurring in normal use See appended table 12.3.11
After the test: inspection show no changes N/A
Repetition of mechanical strength test according N/A
to 12.3.10 See appended table 12.3.11
During application of the pull conductor not N/A
come out of the terminal
Additional test with apparatus shown in figure 11 See appended table 12.3.11 N/A
During the test: conductors not moved noticeably N/A
in the clamping unit
After these tests: neither terminals nor clamping N/A
means have worked loose and conductors show
no deterioration
12.3.12 Screwless terminals: connected rigid solid N/A
conductor remains clamped, even when
deflected during normal installation See appended table 12.3.12
13 CONSTRUCTION OF FIXED SOCKET-OUTLETS P
13.1 Socket-contact assembly: sufficient resilience P
13.2 Socket-contact and pins of socket-outlets: P
resistant to corrosion
13.3 Insulating linings, barriers and the like: P
adequate mechanical strength
13.4 Socket-outlets constructed as to permit P
- easy fixing of the base to a waIl or in a mounting P
box
- easy introduction and connection of the P
conductors in the terminals
TRF No. IEC60884_2_3C
26 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 23 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- easy fixing of the base to a wall or in a mounting P
box;
- easy fixing of the base to a wall or in a mounting P
box
- correct positioning of the conductors P
- adequate space between the underside of the P
base and the surface on which the base is
mounted
- adequate space between the underside of the P
base and the sides of the base and the
enclosure (cover or box)
Socket-outlets classified as design A: permit P
easy positioning and removal of the cover or
cover plate, without displacing the conductors
13.5 Socket-outlets designed that full engagement of P
associated plugs is not prevented by any projection
from their engagement face
Gap between the engagement face of the socket- P
outlet and the plug: not exceed 1 mm
13.6 Covers provided with bushings for the entry holes N/A
for the pins: not possible to remove them from the
outside or for them to become detached
inadvertently from the inside when the cover is
removed
13.7 Covers, cover-plates or parts of them intended to ensure protection against P
electric shock:
- held in place at two or more points by effective P
fixings
- fixed by means of a single fixing, for example, N/A
by a screw, provided that they are Iocated by
another means (for example, by a shouIder)
Fixings of covers or cover-plates of socket- P
outlets of design A serve to fix the base: there
are means to maintain the base in position,
even after removal of the covers or cover-plates
13.7.1 Covers or cover-plates whose fixings are of the screw-type: P
Compliance checked by inspection only For type with design B P
construction (Screw and
rivet method)
13.7.2 Covers or cover-plates whose fixing is not dependent on screws and whose N/A
removal is obtained by applying a force in a direction approximately
perpendicular to the mounting/supporting surface:
TRF No. IEC60884_2_3C
27 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 24 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Compliance checked, when their removal may give access, with the standard N/A
test finger:
to live parts: by the test of 24.14 (verification of N/A
the non-removal and the removal)
to non-earthed metal parts separated from live N/A
parts in such a way that creepage distances and
clearances have the values shown in table 23:
by the test of 24.15 (verification of the non-
removal and the removal)
only to parts of insulating material, or earthed N/A
metal parts, or metal parts separated from live
parts in such a way that creepage distances and
clearances have twice the values shown in table
23, or live parts of SEL V circuits not greater
than 25 V a.c.: by the test of 24.16 (verification
of the non-removal and the removal)
13.7.3 Covers or cover-plates the fixing of which is not dependent on screws and P
whose removal is obtained by using a tool, in accordance with the
manufacturer's instructions given in an instruction sheet or in other
documentation:
Compliance checked, when their removal may give access, with the standard P
test finger:
to live parts: by the test of 24.14 (verification of N/A
the non-removal only)
to non-earthed metal parts separated from live N/A
parts in such a way that creepage distances and
clearances have the values shown in table 23:
by the test of 24.15 (verification of the non-
removal only)
only to parts of insulating material, or earthed P
metal parts, or metal parts separated from live
parts in such a way that creepage distances and
clearances have twice the values shown in table
23, or live parts of SEL V circuits not greater
than 25 V a.c.: by the test of 24.16 (verification For type with design A
of the non-removal only) construction
13.8 Cover-plate intended for a socket-outlet with P
earthing contact: not interchangeable with a cover-
plate intended for a socket-outlet without earthing For type with design A
contact construction
13.9 Surface-type socket-outlets: no free openings in their N/A
enclosures
13.10 Screws or other means for mounting the socket- P
outlet on a surface in a box or enclosure: easily
accessible from the front
TRF No. IEC60884_2_3C
28 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 25 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Fixing means not serve any other fixing purpose P
13.11 Multiple socket-outlets with a common base: P
provided with fixed links for the interconnection
of the contacts in parallel
Fixing of the links independent from the N/A
connection of the supply wires
13.12 Multiple socket-outlets, comprising separate N/A
bases: correct position of each base ensured
Fixing of each base independent of the fixing of N/A
the combination to the mounting surface
13.13 Mounting plate of surface-type socket-outlets: N/A
adequate mechanical strength
13.14 Socket-outlets withstand the lateral strain P
imposed by equipment likely to be introduced
into them
Socket-outlets 16A 250V: test made 4 times with P
the socket-outlet turned through 90°, 5 N for 1
min (device shown in fig. 13)
During the test: device not become disengaged P
from the socket-outlet
After the test: P
- no damage P
- socket-outlets comply with clause 22 P
13.15 Socket-outlets are not an integraI part of P
lampholders
13.16 Surface-type socket-outlets having IP>20 are N/A
according to their IP classification when fitted
with conduits or with sheathed cables and
without a plug in engagement
Surface-type socket-outlets having IPX4 and N/A
IPX5 have provision for opening a drain hole
Socket-outlets with a drain hole: drain hole is N/A
not less than 5 mm in diameter, or 20 mm 2 in
area with a width and a length of not less than 3
mm ..........................................................................:
Drain hole: effective N/A
Lid springs (if any): of corrosion-resistant N/A
material (bronze or stainless steel) ....................:
13.17 Earthing pins: adequate mechanical strength N/A
TRF No. IEC60884_2_3C
29 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 26 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Not solid pins: compliance checked by inspection N/A
and by the test of 14.2 made after the tests of
clause 21
13.18 Earthing contacts and neutral contacts: locked P
against rotation and removable only with the
aid of a tool, after dismantling the socket-outlet
13.19 Metal strips of the earthing circuit: no burrs P
which might damage the insulation of the
supply conductors
13.20 Socket-outlets to be installed in a box: designed P
that the conductor ends can be prepared after
the box is mounted in position, but before the
socket-outlet is fitted in the box
13.21 lnlet openings: allow the introduction of the N/A
conduit or the sheath of the cable
Surface-type socket-outlets: N/A
the conduit or sheath of the cable can enter at N/A
least I mm into the enclosure
inlet opening for conduit entries, or at least two N/A
of them if there are more than one, capable of
accepting conduit sizes of 16, 20, 25 or 32
according to IEC 60423 or a combination of at
least two of any of these sizes
inlet opening for cable entries capable of N/A
accepting cables having the dimensions
specified in table 14 or be as specified by the
manufacturer: rated current (A); Limits of
external dimensions of cable min/max (mm) ..:
13.22 Membranes (grommets) in inlet openings: N/A
reliably fixed and not displaced by the
mechanical and thermal stresses occurring in
normal use
Test on membranes subjected to the ageing treatment specified in 16.1 and N/A
assembled in the accessories
Accessories placed at (40 2) °C for 2 h. Force N/A
of 30 N applied for 5 s by test probe 11 of IEC
61032. During the test: no deformation
Membranes likely to be subjected to an axial pull: N/A
axial pull of 30 N applied for 5 s. During the test:
membranes not become detached
After the test: no harmful deformation, cracks or N/A
similar damage
TRF No. IEC60884_2_3C
30 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 27 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Test repeated with membranes not subjected to N/A
any treatment
13.23 Membranes in inlet openings: introduction of N/A
the cables into the accessory permitted when
the ambient temperature is low
Test on membranes not subjected to the ageing treatment specified in 16.1 N/A
and assembled in the accessories
Accessories kept at (-15 2) °C for 2 h: N/A
possibility to introduce cables of the largest
diameter through membranes
After the test: no harmful deformation, cracks or N/A
similar damage
13.101 Switches shall be constructed to match the P
number of poles of the socket-outlet, except that
the neutral pole is not switched in unswitched
neutral socket-outlets.
The earthing contact is not considered as a pole P
and the earth circuit shall not be switched
The position of the switch operating member P
shall be such that it does not prevent, nor shall
its correct operation be prevented by, the
proper insertion of the corresponding plug or
plugs.
13.102 Knobs of rotary switches shall be securely N/A
coupled to the shaft or the part operating the
mechanism.
The knob is subjected for 1 min to an axial pull N/A
of 100 N.
After, knob having only one direction of N/A
operation are turned 100 times in the reverse
direction.
Knob shall not become detached N/A
13.103 The actuating member of a switch, when P
released, shall automatically take up the
position corresponding
Single push-button the actuating member may N/A
take up a single rest position.
13.104 Switches shall be so constructed that the P
moving contacts can come to rest only in the
Intermediate position permissible if: N/A
TRF No. IEC60884_2_3C
31 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 28 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- it corresponds to the intermediate position of N/A
the actuating member, and
- the insulation between fixed and moving N/A
contacts is adequate. Electric strength test as 500 V / 750 V / 1250 V /
specified in 17.2: test voltage a.c. for 1 min (V) : 2000 V
13.105 Switches shall be constructed so that undue P
arcing cannot occur when the switch is operated
slowly.
Compliance is checked by: P
After the test of clause 21, to break the circuit a P
further ten times
During the test, no sustained arcing shall occur. P
13.106 Switched socket-outlets with switches operating N/A
more than one pole shall make and break all
poles simultaneously. Single pole switch only
Switched neutral, the neutral shall not make N/A
after or break before other poles.
13.107 The action of the mechanism, if the cover or P
cover plates are removable for installation
purposes, shall be independent of the presence
of the covers or cover plates.
14 CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OTLETS N/A
15 INTERLOCKED SOCKET-OUTLETS N/A
16 RESISTANCE TO AGEING, PROTECTION PROVIDED BY ENCLOSURES, AND P
RESISTANCE TO HUMIDITY
16.1 Resistance to ageing P
Accessories are resistant to ageing P
Portable socket-outlets: test plug as specified in
Clause 20 inserted into the socket-outlets N/A
Accessories subjected to a test in a heating cabinet P
at (70 2) °C for seven days (168 h)
After the tests, the specimens show: P
- no crack visible with normal or corrected vision P
without additional magnification
- no sticky or greasy material P
TRF No. IEC60884_2_3C
32 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 29 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- no trace of cloth (forefinger pressed with 5 N) P
- no damage P
Portable socket-outlets: contact pressure of the
contact assembly checked as specified in
subclause 22.2 with the single-pin gauge N/A
16.2 Protection provided by enclosures P
Enclosures provide a degree of protection in P
accordance with the IP designation of the
accessory IP20
16.2.1 Protection against access to hazardous parts and against harmful effects due to P
ingress of solid foreign objects
Accessories and their enclosures provide a degree P
of protection against access to hazardous parts and
against harmful effects due to ingress of solid
foreign objects IP20
Fixed socket-outlets: mounted as in normal use on P
a vertical surface
Flush-type and semi-flush type socket-outlets: P
mounted in an appropriate box according to the
Accessories with screwed glands or membranes fitted with flexible cables within the N/A
range specified in table 3:
- largest cross-sectional area (mm ); type of cable
(table 17) .................................................................: N/A
- smallest cross-sectional area (mm ); type of cable
(table 17) .................................................................: N/A
Glands tightened with a torque equal to 2/3 of the
torque applied during the test of 24.6 (Nm) ..........: N/A
Screws of the enclosure tightened with a torque
equal to 2/3 of the torque given in table 6 (Nm) ...: N/A
16.2.1.1 Protection against access to hazardous parts P
Appropriate test performed as specified in IEC P
60529 (see also clause 10) IP20
16.2.1.2 Protection against harmful effects due to ingress of solid foreign objects P
Appropriate test performed as specified in IEC P
60529 IP20
Test on accessories with IP5X (considered to be of N/A
category 2): dust not penetrated in a quantity to
interfere with satisfactory operation or to impair
safety
16.2.2 Protection against harmful effects due to ingress of water N/A
TRF No. IEC60884_2_3C
33 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 30 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Accessories and their enclosures provide a degree N/A
of protection against harmful effects due to ingress
of water in accordance with their IP classification
Appropriate test performed as specified in IEC 60529 under the following N/A
conditions:
Flush-type and semi-flush type socket-outlets: fixed N/A
in a vertical test wall using an appropriate box
Accessory suitable to be installed on a rough wall: N/A
test wall according to figure 15 is used
Surface-type socket-outlets mounted as for normal use in a vertical position and N/A
fitted with cables (having conductors of the largest and smallest nominal cross-
sectional area given in table 3) or conduits or both in accordance with the
- largest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
- smallest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
Portable socket-outlets tested on a plain, horizontal surface in a position as in
normal use and fitted with flexible cables (having conductors of the largest and
smallest nominal cross-sectional area given in table 3) according to table 17: N/A
- largest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
- smallest cross-sectional area (mm ); type of cable
(table 17) .................................................................:
Screws of enclosure tightened with a torque equal
to 2/3 of the torque given in table 6 (Nm) .............:
Glands tightened with a torque equal to 2/3 of the
torque applied during the test of 24.6 (Nm) ..........:
Accessory with drain holes opened during the test: N/A
any accumulation of water proved by inspection
Socket-outlets tested without a plug in engagement N/A
Plugs tested when in full engagement with: N/A
- a fixed socket-outlets N/A
- a portable socket-outlets N/A
of the same system and with the same degree of
protection against harmful effects due to ingress of
water
Specimens withstand an electric strength test N/A
specified in 17.2 which is started within 5 min of
completion of the IP test
16.3 Resistance to humidity P
TRF No. IEC60884_2_3C
34 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 31 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Accessories proof against humidity which may P
occur in normal use
Compliance checked by a humidity treatment P
carried out in a humidity cabinet containing air with
relative humidity maintained between 91 % and
95 %
Specimens kept in the cabinet for: P
- two days (48 h) for accessories having IPX0 P
- seven days (168 h) for accessories having IP>X0 N/A
After this treatment the specimens show no P
damage
17 INSULATION RESISTANCE AND ELECTRIC STRENGTH P
17.1 Insulation resistance measured 1 min after P
application of 500 V d.c. See appended table 17.1
17.2 Electric strength: a.c. test voltage applied for 1 min See appended table 17.2 P
18 OPERATION OF EARTHING CONTACTS P
Earthing contacts provide adequate contact P
pressure and not deteriorate in normal use
Compliance checked by the tests of clauses 19 and P
21
19 TEMPERATURE RISE P
Temperature rise test See appended table 19 P
Socket-outlets tested using a test plug with P
brass pins having the minimum specified
dimensions
Plugs tested with clamping units having N/A
dimensions specified in Figure 44 fitted on each
live pin and earthing pin, if any
Plugs having lateral earthing contacts and N/A
resilient earthing contacts tested using a fixed
socket-outlet complying with the standard and
having as near to-average characteristics as can
be selected, but with minimum size of the
earthing pin, if any
20 BREAKING CAPACITY P
Accessories have adequate breaking capacity P
Compliance checked by testing: P
TRF No. IEC60884_2_3C
35 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 32 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- socket-outlets; See appended table 20 P
Multiple socket-outlets: test carried out on one P
socket-outlet of each type and current rating with two way outlet
During the test: no sustained arcing occur P
After the test: P
- specimens show no damage impairing their P
further use;
- entry holes for the pins not show any damage P
which may impair the safety
Addition: Switches incorporated in switched socket- P
outlets shall have adequate making and
breaking capacity
- nominal cross-sectional area as for the test of P
clause 17 (mm2) ........................................................ : 2,5
alternating current P
- test voltage (1,1 Vn) (V) ......................................... : 275 P
- test current (1,25 In) (A) ......................................... : 16,25 P
- 200 operations; rate (operations per minute) .. : 30 P
Rotary switches intended to be operated in N/A
either direction, the actuating member is turned
in one direction for half the total number of
operations, and in the reverse direction for the
remainder
During the test: no sustained arcing nor welding of P
the contacts
After the test: specimens show no damage P
21 NORMAL OPERATION P
Switched socket-outlets with interlock shall N/A
withstand without excessive wear or other
harmful effect, the mechanical, electrical and
thermal stresses occurring in normal use
b) The specimens are checked by testing: P
Compliance checked by testing: P
- socket-outlets; See appended table 21 P
After the test the specimens do not show: P
- wear impairing their further use; P
TRF No. IEC60884_2_3C
36 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 33 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- discrepancy between the position of the P
actuating member and that the moving contact;
- deterioration of enclosures, insulating lining or P
barriers;
- damage to the entry holes for the pins, that P
might impair proper working;
- loosening of electrical or mechanical P
connections;
- seepage of sealing compound, N/A
- relative displacement of the moving contacts P
of the switches;
Temperature-rise test (requirements of clause P
19) See appended table 21
Electric strength (sub-clause 17.2) See appended table 21 P
Addition: Switches incorporated in switched socket- P
outlets shall withstand, without excessive wear
or other harmful effect, the mechanical,
electrical and thermal stresses occurring in
normal use
- nominal cross-sectional area as for the test of P
clause 17 (mm2) : 2,5
P
- test voltage (Vn) (V) ............................................... : 250 P
- test current (In) (A) ................................................. : 13 P
- number of operations per table 101 : 40000 P
Rotary switches intended to be operated in N/A
either direction, the actuating member is turned
in one direction for half the total number of
operations, and in the reverse direction for the
remainder
During the test the specimens shall function correctly P
Reduced electric strength per clause 17 without P
humidity treatment See appended table 21 bis
Temperature rise test per clause 19 after normal P
operation See appended table 21 bis
After the tests the specimens not show: P
- wear impairing their further use; P
- discrepancy between the position of the actuating P
member (if indicated) and that of the moving
contacts
TRF No. IEC60884_2_3C
37 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 34 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- deterioration of enclosures, insulating lining or P
barriers;
- seepage of sealing compound N/A
- loosening of electrical or mechanical connections; P
- displacement of moving contacts of switches P
22 FORCE NECESSARY TO WITHDRAW THE PLUG P
Construction of accessory does allow the easy P
insertion and withdrawal of the plug, and
prevent the plug from working out of the socket-
outlet in normal use
22.1 Verification of the maximum withdrawal force See appended table 22 P
22.2 Verification of the minimum withdrawal force See appended table 22 P
23 FLEXIBLE CABLES AND THEIR CONNECTIONS N/A
24 MECHANICAL STRENGTH P
Accessories, surface mounting boxes, screwed P
glands and shrouds have adequate mechanical
strength
24.1 Fixed socket-outlets, portable multiple socket- P
outlets and surface-type mounting boxes: impact
test (apparatus shown in fig. 22, 23, 24 and 25) See appended table 24.1
After the test: no damage, live parts no become P
accessible
24.2 Portable single socket-outlets and plugs: subjected
to test Ed: Free fall, procedure 2 of IEC 60068-2-32
(tumbling barrel); number of falls .......................... : N/A
After the test: N/A
- no part become detached or loosened; N/A
- pins no become so deformed that the plug cannot N/A
be introduced into a socket-outlet and also fails to
comply with the requirements of 9.1 and 10.3;
- pins no turn when a torque of 0,4 Nm is applied N/A
for 1 min in each direction
24.3 Bases of surface-type socket-outlets: first fixed to a cylinder of rigid steel sheet and N/A
then fixed to a flat steel sheet
During and after the tests: no damage N/A
24.4 Portable single socket-outlets, multiple socket-outlets and plugs (electrometric or
thermoplastic material): impact test, weight (1000 2) g, height 100 mm (apparatus
shown in fig. 27) N/A
TRF No. IEC60884_2_3C
38 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 35 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Specimens placed in a freezer at (-15 °C ± 2) °C for N/A
at least 16 h. After the test: no damage
24.5 Portable single socket-outlets and plugs (electrometric or thermoplastic material):
compression test, 300 N for 1 min, position a) and b) (apparatus shown in fig. 8) N/A
After the test: no damage N/A
24.6 Screwed glands of accessories having IP>20: torque test (1 min) N/A
- diameter of test rod (mm) ................................... :
- type of material (metal / moulded) ...................... :
- torque (Nm) .......................................................... :
After the test: no damage of glands and enclosures N/A
of the specimens
24.7 Plug pins provided with insulating sleeves: 20000 movements, 4 N (apparatus N/A
shown in fig. 28)
24.8 Shuttered socket-outlets: mechanical test carried out on specimens submitted to P
the normal operation test according to clause 21
Force (40 N / 75 N) applied for 1 min against the
shutter of an entry hole by means of one pin (N) : 75N
Pin did not come in contact with live parts P
After the test: no damage P
24.9 Mechanical test for multiple portable socket-outlet: 8 falls on concrete floor with the
specimens arranged as shown in figure 29 N/A
Rewirable multiple socket-outlets: flexible cable of
the smallest cross-sectional area specified in table
3 ...............................................................................:
After the test: no damage, no part have become N/A
detached or loosened
Accessories having IP>X0 submitted again to the N/A
tests as specified in 16.2
24.10 Plugs: pull test to verify the fixation of pins in the body of the plug (new specimens) N/A
Maximum withdrawal force (table 16) applied for 1
min on each pin in turn, after the specimen has
been placed at (70 2) °C for 1 h (N) .................. :
After the test: displacement of pins in the body of N/A
the plug 1 mm (mm) ........................................... :
24.11 Barriers of portable socket-outlets having means for suspension on a mounting
surface: N/A
Force applied for 10 s against the barrier by means
of a cylindrical steel rod (1,5 times the maximum
plug withdrawal force in 22.1, table 16) (N) ......... :
Rod did not pierce the barrier N/A
TRF No. IEC60884_2_3C
39 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 36 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
24.12 Portable socket-outlets having means for suspension on a mounting surface (pull
test): N/A
Pull applied to the supply flexible cable for 10 s
(force prescribed in 23.2 for checking the flexible
cable anchorage) (N) ............................................. :
During the test: no break of the means for N/A
suspension on a mounting surface
24.13 Portable socket-outlets having means for suspension on a mounting surface (pull
test): N/A
Pull applied to the engagement face of the socket-
outlet for 10 s (maximum withdrawal force
specified, for the corresponding plug, in table 16)
(N) ........................................................................... :
During the test: no break of the means for N/A
suspension on a mounting surface
24.14 Forces necessary to retain or remove covers, cover-plates or parts of them N/A
(accessibility with the test finger to live parts)
24.14.1 Verification of the retention of covers or cover-plates (fixed socket-outlets) N/A
Force (40 N / 80 N) applied for 1 min perpendicular
to the mounting surface (N) .................................. : N
Covers or cover-plates did not come off N/A
Test repeated on new specimens with a sheet of N/A
hard material, (1 ± 0,1) mm thick, fitted around the
supporting frame (fig. 31): covers or cover-plates
did not come off
After the test: no damage N/A
24.14.2 Verification of the removal of covers or cover-plates (fixed socket-outlets) N/A
Force not exceeding 120 N applied 10 times N/A
perpendicular to the mounting / supporting surface:
covers or cover-plates came off Not came off
Test repeated on new specimens with a sheet of N/A
hard material, (1 ± 0,1) mm thick, fitted around the
supporting frame (fig. 31): covers or cover-plates
came off
After the test: no damage N/A
24.14.3 Verification of the retention of covers or cover-plates (plugs and portable socket-
outlets) N/A
Force 80 N applied for 1 min perpendicular to the N/A
mounting surface: covers, cover-plates or parts of
them did not come off
Test repeated with a force of 120 N: N/A
Rewirable plugs and rewirable portable socket- N/A
outlets: covers, cover-plates or parts of them came
off but the specimen showed no damage
TRF No. IEC60884_2_3C
40 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 37 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Non-rewirable, non moulded-on accessories: N/A
covers, cover-plates or parts of them came off but
the accessories were permanently useless
according to 14.1
24.15 Force necessary for covers or cover-plates to come off or not to come off N/A
(accessibility with the test finger to non-earthed metal parts separated from live
parts by _reepage distances and clearances according to table 23)
24.14.1 Verification of the non-removal of covers or cover-plates N/A
Force (10 N / 20 N) applied for 1 min in direction
perpendicular to the mounting surface (N) .......... :
Covers or cover-plates did not come off N/A
Test repeated on new specimens with a sheet of N/A
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates did not come off
After the test: no damage N/A
24.14.2 Verification of the removal of covers or cover-plates N/A
Force not exceeding 120 N applied 10 times in N/A
direction perpendicular to the mounting / supporting
surface: covers or cover-plates came off
Test repeated on new specimens with a sheet of N/A
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates came off
After the test: no damage N/A
24.16 Force necessary for covers or cover-plates to come off or not to come off P
(accessibility to insulating parts, earthed metal parts, live parts of SELV 25 V a.c.
or metal parts separated from live parts by _reepage distances twice those
according to table 23)
24.14.1 Verification of the non-removal of covers or cover-plates P
Force 10 N applied for 1 min in direction Not come off (for type with P
perpendicular to the mounting surface: covers or design A construction)
cover-plates did not come off
Test repeated on new specimens with a sheet of P
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates did not come off
After the test: no damage P
24.14.2 Verification of the removal of covers or cover-plates P
Force not exceeding 120 N applied 10 times in Not come off (for type with N/A
direction perpendicular to the mounting / supporting design A construction)
surface: covers or cover-plates came off
TRF No. IEC60884_2_3C
41 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 38 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Test repeated on new specimens with a sheet of P
hard material, 1 mm ± 0,1 mm thick, fitted around
the supporting frame (fig. 31): covers or cover-
plates came off
After the test: no damage P
24.17 Test with gauge of figure 7 applied according to complying / not complying
figure 9 for verification of the outline of covers or
cover-plates: distances between face C of gauge
and outline of side under test, not decrease ....... :
24.18 Test with gauge according to figure 5 applied as complying / not complying
shown in figure 11 (1 N): gauge not enter more
than 1mm ............................................................... :
24.19 Shroud of portable socket-outlets: compression test (20 2) N at (25 5) °C by
means of the apparatus shown in figure 38 N/A
After 1 min and while the shrouds are still under N/A
pressure the dimensions did comply with the
appropriate standard sheet
Test repeated with the specimen rotated 90 ° N/A
25 RESISTANCE TO HEAT P
25.1 Specimens kept for 1 h in a heating cabinet at (100 2) °C for 1 h P
During the test: no change impairing their further use P
and sealing compound, if any, not flow
After the test: P
- no access to live parts with probe B of IEC 61032 P
applied with a force not exceeding 5 N
- markings still legible P
25.2 Parts of insulating material necessary to retain P
current-carrying parts and parts of the earthing
circuit in position, as well as parts of the front surface
zone, 2 mm wide, surrounding the phase and neutral
pin entry holes: ball-pressure test at (125 2)°C for
1h See appended table 25.2
25.3 Parts of insulating material not necessary to retain P
current-carrying parts and parts of the earthing
circuit in position, even though in contact with them:
ball-pressure test (1 h) See appended table 25.3
25.4 Portable accessories: compression test (20 N) at (80 2)°C for 1 h by means of the
apparatus shown in figure 38 N/A
After the test: no damage N/A
26 SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS P
26.1 Connections withstand mechanical stresses P
TRF No. IEC60884_2_3C
42 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 39 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Thread-forming or thread-cutting screws used only N/A
if supplied together with the piece in which they are
intended to be inserted
Thread-cutting screws intended to be used during N/A
installation: captive
Screws and nuts which transmit contact pressure: N/A
in engagement with a metal thread
Threaded part torque test See appended table 26.1 P
26.2 Screws in engagement with a thread of insulating P
material: correct introduction into the screw hole or
nut ensured
26.3 Contact pressure: not transmitted through P
insulating material other than ceramic, pure mica or
other material no less suitable unless there is
sufficient resiliency in metallic parts
Connections made by insulation piercing of tinsel N/A
cord reliable
26.4 Screws and rivets locked against loosening and/or P
turning
26.5 Current-carrying parts (including earthing terminals) have mechanical strength, P
electrical conductivity and resistance to corrosion adequate:
- copper; N/A
- alloy with at least 58 % copper for parts made from P
cold-rolled sheet or with at least 50 % copper for
other parts; >59%
- stainless steel with at least 13 % chromium and not N/A
more than 0,09 % carbon
- steel with electroplated coating of zinc (ISO 2081): N/A
service condition ISO no. (1/2/3); IP (X0/X4/X5);
thickness (µm) ........................................................... :
- steel with electroplated coating of nickel and N/A
chromium (ISO 1456): service condition ISO no.
(2/3/4); IP (X0/X4/X5); thickness (µm) ...................... :
- steel with electroplated coating of tin (ISO 2093): N/A
service condition ISO no. (2/3/4); IP (X0/X4/X5);
thickness (µm) ........................................................... :
Current-carrying parts subjected to mechanical P
wear: not of steel with electroplated coating
Metals having a great difference of electrochemical N/A
potential: not used in contact with each other
26.6 Contacts subjected to a sliding action are of metal P
resistant to corrosion
TRF No. IEC60884_2_3C
43 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 40 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
26.7 Thread-forming screws and thread-cutting screws N/A
are not used for the connection of current-carrying
parts
Thread-forming screws and thread-cutting screws N/A
used to provide earthing connection: it is not
necessary to disturb the connection and at least two
screws are used for each connection
27 CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH P
SEALING COMPOUND
27.1 Creepage distances, clearances and distances P
through sealing compound are not less than the
values shown in table 23 See appended table 27.1
27.2 Insulating sealing compound does not protrude N/A
above the edge of the cavity in which it is contained
27.3 Surface-type socket-outlets do not have bare N/A
current-carrying strips at the back
27.101 For switches incorporated in switched socket-outlets, P
creepage distances, clearances and distances
through sealing compound shall be not less than the
values shown in table 102
28 RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND P
TO TRACKING
28.1 Resistance to abnormal heat and to fire P
28.1.1 Glow-wire test according to IEC 60695-2-10 and IEC P
60695-2-11 See appended table 28.1.1
28.1.2 Plugs with pins provided with insulating sleeves: N/A
28.2 Resistance to tracking N/A
Parts of insulating material retaining live parts in N/A
position of accessories having IP>X0: of material
resistant to tracking
Tracking test at 175 V with solution A of IEC 60112 See appended table 28.2 N/A
29 RESISTANCE TO RUSTING P
Ferrous parts protected against rusting P
Test made after having removed all grease using a suitable degreasing agent: 10 P
min 10 % solution of ammonium chloride, 10 min in a box with air saturated with
moisture and 10 min at (100 5) °C:
No signs of rust P
TRF No. IEC60884_2_3C
44 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 41 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
30 ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES N/A
TRF No. IEC60884_2_3C
45 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 42 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
12.2.5 TABLE: test with apparatus shown in figure 11 (screw-type terminals) P
rated current (A) ...................................................... : 13A
type of conductors .................................................. : rigid solid / rigid stranded /
flexible
smallest/largest cross-sectional area per table 3
(mm2) ......................................................................... : 1,5/2,5/4,0
number of conductors ............................................. : 1/3/2
nominal diameter of thread (mm); torque per
table 6 (Nm) .............................................................. : 3,9mm; 1,2Nm
Diameter of
Cross-sectional Height H per table 9
bushing hole per Mass (kg) Remarks
area (mm2) (mm)
table 9 (mm)
1,5 6,5 260 0,4 P
2,5 9,5 280 0,7 P
4,0 9,5 280 0,9 P
supplementary information:
12.2.6 TABLE: pull test (screw-type terminals) P
rated current (A) ...................................................... : 13A 250V~
smallest/largest cross-sectional area per table 3
(mm2) ......................................................................... : 1,5/3X2,5/2X4,0
nominal diameter of thread (mm); torque 2/3 per
table 6 (Nm) .............................................................. : 3,9mm; 0,8Nm
Type of conductors Pull per table 4
Cross-sectional Number of
(rigid solid / rigid applied for 1 min Remarks
area (mm2) conductors
stranded / flexible) (N)
1,5 1 Rigid solid 40 P
2,5 3 Rigid solid 50 P
4,0 2 Rigid solid 50 P
supplementary information:
12.2.7 TABLE: tightening test (screw-type terminals) P
rated current (A) ...................................................... : 13A 250V~
nominal diameter of thread (mm); torque 2/3 per
table 6 (Nm) .............................................................. : 3,9mm; 0,8Nm
Number of wires
Largest cross- Permissible Type of conductors
and nominal
sectional area per number of (rigid solid / rigid Remarks
diameter of wires
table 3 (mm2) conductors (1) stranded / flexible)
per table 5
TRF No. IEC60884_2_3C
46 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 43 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
2,5 3 Rigid solid/Rigid P
stranded 1x1,78/7X0,67
4,0 2 Rigid solid/Rigid P
stranded 1x2,25/7X0,86
supplementary information: (1) terminals intended for looping-in 2 or 3 conductors
12.3.10 TABLE: mechanical strength test (screwless-type terminals) N/A
rated current (A) ...................................................... :
largest/smallest cross-sectional area per table 7
(mm2) ......................................................................... :
Number of connection (after Type of conductor (solid / Cross-sectional Remarks
that conductor subjected to a rigid stranded / flexible area (mm2)
pull of 30 N for 1 min) /
disconnection
TABLE: test with apparatus shown in figure 11
Type of Diameter of
Cross-
conductor (solid bushing hole Height H per
sectional area Mass (kg) Remarks
/ rigid stranded / per table 9 table 9 (mm)
(mm2)
flexible (mm)
supplementary information:
12.3.11 TABLE: electrical and thermal strength test (screwless-type terminals) N/A
Test a) Test carried out for 1 h connecting rigid solid conductors:
test current per table 10 (A) ................................... :
nominal cross-sectional area (mm2) ..................... :
Screwless terminal number Voltage drop (mV) Required voltage drop (mV)
1 15
2 15
3 15
4 15
5 15
Test b) Temperature cycles test carried out on terminals subjected to Test a):
test current per table 10 (A) ................................... :
nominal cross-sectional area (mm2) ..................... :
TRF No. IEC60884_2_3C
47 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 44 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
allowed voltage drop (mV) ..................................... : 22,5 mV or 2 times 24th cycle
value (mV)
Screwless terminal number 1 2 3 4 5 Remarks
voltage drop after 24th cycle
voltage drop after 48th cycle
voltage drop after 72nd cycle
voltage drop after 96th cycle
voltage drop after 120th cycle
voltage drop after 144th cycle
voltage drop after 168th cycle
voltage drop after 192nd cycle
12.3.10 TABLE: mechanical strength test (screwless-type terminals)
rated current (A) ...................................................... :
largest/smallest cross-sectional area per table 7
(mm2) ......................................................................... :
Number of connection (after Type of conductor (solid / Cross-sectional Remarks
that conductor subjected to a rigid stranded / flexible area (mm2)
pull of 30 N for 1 min) /
disconnection
TABLE: test with apparatus shown in figure 11
Type of Diameter of
Cross-
conductor (solid bushing hole Height H per
sectional area Mass (kg) Remarks
/ rigid stranded / per table 9 table 9 (mm)
(mm2)
flexible (mm)
supplementary information:
12.3.12 TABLE: deflection test (principle of test apparatus shown in figure 12a) N/A
Test carried out connecting rigid solid copper conductors:
test current (A) (equal rated current) .................... :
required voltage drop (mV) .................................... : 25 mV
Type of conductor Smallest Largest Remarks
cross-sectional area per table 11 (mm2)
force per table 12 (N)
TRF No. IEC60884_2_3C
48 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 45 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
screwless terminal number 1 2 3 1 2 3
starting point (X = deflection original X X+10° X+20° X X+10° X+20°
point)
voltage drop 1st deflection (mV)
voltage drop 2nd deflection (mV)
voltage drop 3rd deflection (mV)
voltage drop 4th deflection (mV)
voltage drop 5th deflection (mV)
voltage drop 6th deflection (mV)
voltage drop 7th deflection (mV)
voltage drop 8th deflection (mV)
voltage drop 9th deflection (mV)
voltage drop 10th deflection (mV)
voltage drop 11th deflection (mV)
voltage drop 12th deflection (mV)
supplementary information:
17.1 TABLE: insulation resistance P
Test voltage applied between: Item per 17.1 measured (M ) required (M )
a) between all poles connected together and the body,
with a plug in engagement 199 5
b between each pole in turn and all others connected
199 5
to the body, with a plug in engagement
f) between all poles connected together and the body,
199 5
g) between each pole in turn and all others connected
199 2
h) between the terminals which are electrically
199 2
supplementary information:
17.2 TABLE: electric strength P
rated voltage (V) ...................................................... : 250V~
TRF No. IEC60884_2_3C
49 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 46 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
flashover /
Test voltage applied between: item per 17.1 test voltage (V) breakdown
(Yes/No)
a) between all poles connected together and the body,
2000 P
with a plug in engagement
b) between each pole in turn and all others connected
2000 P
to the body, with a plug in engagement
f) between all poles connected together and the body,
2000 P
g) between each pole in turn and all others connected
2000 P
h) between the terminals which are electrically
2000 P
supplementary information:
19 TABLE: temperature rise test P
rated current of accessory (A) ............................... : 13A
type of accessory .................................................... : Rewirable
nominal cross-sectional area per table 15 (mm2) 1,5 / rigid conductor
(rewirable accessories) / type of conductor ........ :
type of conductors (rigid solid / rigid stranded / rigid solid
flexible) (rewirable accessories) ........................... :
nominal diameter of thread (mm); torque 2/3 of
that specified in 12.2.8 (Nm) (rewirable
accessories) ............................................................. : 3,9mm; 0,8Nm
temperature
number of test rise of
conductors current measured allowed external
test circuit
specimen and nominal (table 20) dT dT parts of
(L-L/L-N/L-E)
cross-sectional for 1 h (K) (K) insulating
area (mm2) (A) material
(25.3)
1,5 L-N/L-E 14A+6A Max. 40 45 Max. 23
supplementary information:
this clause is based on IEC 60884-1 A2: 2013
20 TABLE: breaking capacity P
TRF No. IEC60884_2_3C
50 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 47 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
rating of accessory (A/V) ........................................ : 13A 250V~
type of accessory ................................................... : rewirable
nominal cross-sectional area per table 15 (mm2) / 1,5mm; rigid conductor
type of conductor .................................................... :
type of conductors (rigid solid / rigid stranded / rigid solid
flexible) ...................................................................... :
nominal diameter of thread (mm); torque 2/3 of
that specified in 12.2.8 (Nm) (rewirable
accessories) ............................................................. : 3,9mm; 0,8Nm
rate of operation (strokes per minute) ................ : 30
test plug (for each number
type and current number of
test number
rating of socket- test of strokes, strokes,
current of
outlet) voltage with without
specimen (1,25 In) strokes remarks
(1,1 Vn) shutters shutters
pin pin cos 0,6 (plugs
(V) with with
dimensions spacing (A) only)
current (1) current
(mm) (mm) (2)
- - 275 16,25 - 100 - - P
supplementary information:
(1)
starting point 1 or 3 of Figure 43
(2)
starting point 2 of Figure 43
21 TABLE: normal operation P
rating of accessory (A/V) ........................................ : 13A 250V~
type of accessory ................................................... : rewirable
2
nominal cross-sectional area per table 15 (mm ) / 1,5mm; rigid conductor
type of conductor .................................................... :
type of conductors (rigid solid / rigid stranded / rigid solid
flexible) ...................................................................... :
nominal diameter of thread (mm); torque 2/3 of that
specified in 12.2.8 (Nm)........................................... : 3,9mm; 0,8Nm
rate of operation (strokes per minute) ................ : 30
test plug (for each number
number
type and current of
number of
rating of socket- test number strokes,
test of strokes, strokes,
outlet) current of with
voltage with without
specimen (table 20), strokes shutters
(Vn) shutters shutters
pin pin cos 0,8 (plugs
(V) with with
dimensions spacing (A) only) without
current (1) current
(mm) (mm) (2) current
(3)
TRF No. IEC60884_2_3C
51 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 48 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
- - 250 13 - 10000 - - P
TABLE: test for shuttered socket-outlets P
Gauge of figure 9, applied with a force of Steel gauge of figure 10, applied with
specimen 20 N, for approximately 5 s, successively a force of 1 N for approximately 5 s,
in three directions in three directions
- OK OK P
19 TABLE: temperature rise test P
test current (table 20 for
test circuit measured dT allowed dT
specimen clause 21) for 1 h
(L-L/L-N/L-E) (K) (K)
(A)
L-N/L-E 13 Max. 42 45 P
17.2 TABLE: electric strength P
flashover /
item per
specimen test voltage applied between: test voltage (V) breakdown
17.1
(Yes/No)
- a) between all poles connected together and
1500 No
the body, with a plug in engagement
b) between each pole in turn and all others
connected to the body, with a plug in 1500 No
engagement
supplementary information: (1) starting point 1 or 3 of Figure 43 ; (2) starting point 2 of Figure 43;
(3)
starting point 1 or 2 of Figure 43
21 (bis) TABLE: reduced electric strength after normal operation (for switches) P
flashover /
item per
test voltage applied between: test voltage (V) breakdown
17.1
(Yes/No)
f) between all poles connected together and the body,
2000 No
g) between each pole in turn and all others connected
2000 No
h) between the terminals which are electrically
2000 No
TABLE: temperature rise measurements at terminals after normal operation P
(for switches)
test current (In) passed for 1 h (A) ...................... : 13A
max. measured allowed
thermocouple locations temperature rise temperature rise
(K) (K)
TRF No. IEC60884_2_3C
52 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 49 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Terminals L Max. 41 45
supplementary information:
22 TABLE: force necessary to withdraw the plug P
Rated current (A) ..................................................... : 13A
Number of poles ..................................................... : 2P+E
22.1 Verification of the maximum withdrawal force P
socket-outlets (multi-pin gauge)
specimen maximum withdrawal force the test plug did not remain in the socket-outlet
(N) (Y/N)
- 50N N (not remain) P
22.2 Verification of the minimum withdrawal force P
socket-outlets (single-pin gauge)
specimen minimum withdrawal force the test pin gauge did not fall from each
(N) individual contact-assembly within 30 s (Y/N)
- 1.5N N (not fall) P
supplementary information:
Based on IEC 60884-1 A2:2013
24.1 TABLE: impact test P
part of enclosure tested
blows per part height of fall (mm) comments
per table 21 (A, B, C, D)
A 5 80 P
B 4 80 P
supplementary information:
Based on IEC 60884-1 A2:2013
25.2 TABLE: ball pressure test of insulating materials P
allowed impression diameter (mm) ......................: 2 mm
test temperature impression
part under test
( C) diameter (mm)
Switch rocker, cover plate (Makrolon PC) 125 1,6
Base 125 1,6
Front cover (UREA material) 125 1,2
Shutter box (PC with type RX2123) 125 1,5
TRF No. IEC60884_2_3C
53 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 50 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
supplementary information: for model 617*44,28**36,832*79,833*79, 282443***, K8/15/13/U2***-HK,
57****, 730079,738143
25.2 TABLE: ball pressure test of insulating materials P
allowed impression diameter (mm) ......................: 2 mm
test temperature impression
part under test
( C) diameter (mm)
Rocker (PC material, MEP, Covestro) 125 Max. 1,5
Front cover (PC material, Covestro) 125 Max. 1,5
Cover plate (PC material, Covestro, Taisu, SABIC, Kingfa) 125 Max. 1,5
Base (PP material, Silver age, Taisu) 125 Max. 1,5
Shutter box 125 Max. 1,5
supplementary information: for model 281136** series
25.3 TABLE: ball pressure test of insulating materials P
allowed impression diameter (mm) ......................: 2 mm
test temperature impression
part under test
( C) (1) diameter (mm)
Shutter body (Kingfa) 70 Max. 1,0
Plastic frame (PC FR6005+(z)) 70 Max. 1.1
supplementary information: for model 617*44,28**36,832*79,833*79, 282443***, K8/15/13/U2***-HK,
57****, 730079,738143
25.3 TABLE: ball pressure test of insulating materials P
allowed impression diameter (mm) ......................: 2 mm
test temperature impression
part under test
( C) (1) diameter (mm)
Shutter body (PA material, Wen An, Taisu) 70 Max. 1,3
Rocker shell (PC material, SABIC, Covestro) 70 Max. 1,2
supplementary information: (1) (70 ± 2) °C / (40 ± 2) °C + highest temperature rise determined during the test
of clause 19
26.1 TABLE: threaded part torque test P
diameter of column applied
times
threaded part identification thread number torque no damage
(5/10)
(mm) (1, 2 or 3) (Nm)
TRF No. IEC60884_2_3C
54 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 51 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Terminal screws 3,9 2 1,2 5 P
supplementary information:
27.1 TABLE: creepage distances, clearances and distances through sealing P
compound
rated voltage (V) ...................................................... : 250V~
creepage distance dcr, clearance required required
item per required
dcr dcr dtsc dtsc
table 23
cl and distance through sealing cl (mm) cl (mm) (mm) (mm)
compound dtsc at/of: (mm) (mm)
1); 6) between live parts of different polarity 3 > 4 (by 3 > 4 (by -
gauge) gauge)
2); 7) between live parts and accessible 3 > 4 (by 3 > 4 (by -
surface of parts of insulating material gauge) gauge)
2); 7) between live parts and earthed metal 3 > 4 (by 3 > 4 (by -
parts including parts of earthing gauge) gauge)
circuit
- screws or devices for fixing bases, 3 > 4 (by 3 > 4 (by -
covers or cover-plates of fixed gauge) gauge)
socket-outlets
4) between the accessible unearthed - 4,5 > 5 (by -
metal parts of a socket outlet and a gauge)
fully engaged plug of the same
system having pins and metal parts
connected to them made according to
the most unfavourable construction
5) between live parts of a socket outlet - 4,5 > 5 (by -
(without a plug) or of a plug and their gauge)
accessible unearthed or functional
earthed metal parts
8) between live parts and accessible 6 > 7 (by - -
unearthed or functional earthed metal gauge)
parts of socket outlet and plugs
1); 4) between live parts which are 3 3,5 3 > 4 (by -
separated when the contacts are gauge)
(for switch)
open
supplementary information:
28.1.1 TABLE: glow-wire test P
visible
flame and flame and
test ignition of
glowing
part under test material designation temperature sustained the tissue
extinction
( C) glowing paper (Y/N)
time
(Y/N)
TRF No. IEC60884_2_3C
55 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 52 of 102 Report No. 220300360SHA-001
IEC 60884-2-3
Clause Requirement + Test Result - Remark Verdict
Switch rocker/cover PC (Makrolon) 850 Y 5s N
plate /front cover
Base PP 850 Y 3s N
Shutter box PC (Type RX2123) 850 N - N
Front cover UREA 850 N - N
Shutter PA6 650 N - N
Plastic frame PC (FR6005+(z)) 650 N - N
supplementary information: for model 617*44,28**36,832*79,833*79, 282443***, K8/15/13/U2***-HK,
57****, 730079,738143
28.1.1 TABLE: glow-wire test P
visible
flame and
test flame and ignition of
material glowing
part under test temperature sustained the tissue
designation extinction
( C) glowing paper (Y/N)
time
(Y/N)
Rocker (MEP, Covestro) PC 850 N 2s N
Front cover (Covestro) PC 850 N 10s N
Cover plate (Covestro, Taisu,
PP 650 N - N
SABIC, Kingfa)
Base (Silver age, Taisu) PP 850 N 2s N
Shutter box PC 850 N 10s N
Shutter body (Wen An, Taisu) PA 650 N - N
Rocker shell (SABIC, Covestro) PC 650 N - N
supplementary information: for model 281136** series
28.2 TABLE: resistance to tracking N/A
number of drops ................................................... :
flashover /
test voltage
part under test material designation breakdown
(V)
(Yes/No)
supplementary information:
TRF No. IEC60884_2_3C
56 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 53 of 102 Report No. 220300360SHA-001
Photos:
Front view of 282443
Back view of 282443
TRF No. IEC60884_2_3C
57 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 54 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 282443
Inside view of 282443
TRF No. IEC60884_2_3C
58 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 55 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 282443
Inside view of 282443
TRF No. IEC60884_2_3C
59 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 56 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 282443
Inside view of 282443
TRF No. IEC60884_2_3C
60 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 57 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 282443
Inside view of 282443
TRF No. IEC60884_2_3C
61 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 58 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 282443
Shutter
TRF No. IEC60884_2_3C
62 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 59 of 102 Report No. 220300360SHA-001
Photos:
Shutter
Shutter
TRF No. IEC60884_2_3C
63 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 60 of 102 Report No. 220300360SHA-001
Photos:
Terminal
Switch rocker
TRF No. IEC60884_2_3C
64 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 61 of 102 Report No. 220300360SHA-001
Photos:
Front view of 282443-C2
Back view of 282443-C2
TRF No. IEC60884_2_3C
65 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 62 of 102 Report No. 220300360SHA-001
Photos:
Front view of 282443-C3
Back view of 282443-C3
TRF No. IEC60884_2_3C
66 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 63 of 102 Report No. 220300360SHA-001
Photos:
Front view of 281136
Inside view of 281136
TRF No. IEC60884_2_3C
67 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 64 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 281136
From left to right for first row: Front view of 282136,283136
From left to right for second row: Front view of 283336,283536
For third row: Front view of 283936
TRF No. IEC60884_2_3C
68 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 65 of 102 Report No. 220300360SHA-001
Photos:
From left to right for first row: Back view of 282136,283136
From left to right for second row: Back view of 283336,283536
For third row: Back view of 283936
From left to right: Front view of 617144, 617344,617444
TRF No. IEC60884_2_3C
69 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 66 of 102 Report No. 220300360SHA-001
Photos:
From left to right: Front view of 617144, 617344,617444
From up to down: Front view of 730079,738143
TRF No. IEC60884_2_3C
70 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 67 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 738143
From left to right: Front view of 833079,833279,833479
TRF No. IEC60884_2_3C
71 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 68 of 102 Report No. 220300360SHA-001
Photos:
From left to right: Back view of 833079,833279,833479
Front view of 833079
TRF No. IEC60884_2_3C
72 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 69 of 102 Report No. 220300360SHA-001
Photos:
Back view of 833079
Switch rocker for 833079
TRF No. IEC60884_2_3C
73 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 70 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 833079
From left to right: Front view of 832079,832279,832479
TRF No. IEC60884_2_3C
74 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 71 of 102 Report No. 220300360SHA-001
Photos:
From left to right: Back view of 832079,832279,832479
Front view of 572142
TRF No. IEC60884_2_3C
75 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 72 of 102 Report No. 220300360SHA-001
Photos:
Back view of 572142
Front view of 572642
TRF No. IEC60884_2_3C
76 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 73 of 102 Report No. 220300360SHA-001
Photos:
Back view of 572642
From up to down: Front view of 571081, 570081
TRF No. IEC60884_2_3C
77 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 74 of 102 Report No. 220300360SHA-001
Photos:
From up to down: Back view of 571081, 570081
Front view of plastic cover 575117
TRF No. IEC60884_2_3C
78 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 75 of 102 Report No. 220300360SHA-001
Photos:
Back view of plastic cover 575117
Front view of metal cover 575118
TRF No. IEC60884_2_3C
79 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 76 of 102 Report No. 220300360SHA-001
Photos:
Back view of metal cover 575118
Front view of 572142 with plastic cover 575117
TRF No. IEC60884_2_3C
80 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 77 of 102 Report No. 220300360SHA-001
Photos:
Back view of 572142 with plastic cover 575117
Inside view of 572142 with plastic cover 575117
TRF No. IEC60884_2_3C
81 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 78 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 572142 with plastic cover 575117
Front view of 572142 with metal cover 575118
TRF No. IEC60884_2_3C
82 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 79 of 102 Report No. 220300360SHA-001
Photos:
Back view of 572142 with metal cover 575118
Inside view of 572142 with metal cover 575118
TRF No. IEC60884_2_3C
83 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 80 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 572142 with metal cover 575118
Front view of 572642 with plastic cover 575117
TRF No. IEC60884_2_3C
84 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 81 of 102 Report No. 220300360SHA-001
Photos:
Back view of 572642 with plastic cover 575117
Inside view of 572642 with plastic cover 575117
TRF No. IEC60884_2_3C
85 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 82 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 572642 with plastic cover 575117
Front view of 572642 with metal cover 575118
TRF No. IEC60884_2_3C
86 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 83 of 102 Report No. 220300360SHA-001
Photos:
Back view of 572642 with metal cover 575118
Inside view of 572642 with metal cover 575118
TRF No. IEC60884_2_3C
87 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 84 of 102 Report No. 220300360SHA-001
Photos:
From left to right: Front view of 617644,617744,617844
From left to right: Back view of 617644,617744,617844
TRF No. IEC60884_2_3C
88 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 85 of 102 Report No. 220300360SHA-001
Photos:
Front view of 617644
Back view of 617644
TRF No. IEC60884_2_3C
89 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 86 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 617644
Front view of 617744
TRF No. IEC60884_2_3C
90 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 87 of 102 Report No. 220300360SHA-001
Photos:
Back view of 617744
Inside view of 617744
TRF No. IEC60884_2_3C
91 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 88 of 102 Report No. 220300360SHA-001
Photos:
Front view of 617844
Back view of 617844
TRF No. IEC60884_2_3C
92 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 89 of 102 Report No. 220300360SHA-001
Photos:
Inside view of 617844
Inside view of 617844
TRF No. IEC60884_2_3C
93 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 90 of 102 Report No. 220300360SHA-001
Photos:
Switch rocker
Switch rocker
TRF No. IEC60884_2_3C
94 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 91 of 102 Report No. 220300360SHA-001
Photos:
Switch rocker
From left to right for first row: Front view of K8/15/13/U2-HK, K8/15/13/U2-C-HK, K8/15/13/U2-C1-HK
From left to right for second row: Front view of K8/15/13/U2-C2-HK, K8/15/13/U2-C3-HK,
K8/15/13/U2-C4-HK
TRF No. IEC60884_2_3C
95 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 92 of 102 Report No. 220300360SHA-001
Photos:
From left to right for first row: Front view of K8/15/13/U2-HK, K8/15/13/U2-C-HK, K8/15/13/U2-C1-HK
From left to right for second row: Front view of K8/15/13/U2-C2-HK, K8/15/13/U2-C3-HK,
K8/15/13/U2-C4-HK
Inside view of K8/15/13/U2-C1-HK
TRF No. IEC60884_2_3C
96 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 93 of 102 Report No. 220300360SHA-001
Photos:
Inside view of K8/15/13/U2-C1-HK
From left to right: Front view of 282443-C1, 282443-C, 282443
TRF No. IEC60884_2_3C
97 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 94 of 102 Report No. 220300360SHA-001
Photos:
From left to right: Back view of 282443-C1, 282443-C, 282443
From left to right: Inside view of 282443, 282443-C1, 282443-C
TRF No. IEC60884_2_3C
98 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 95 of 102 Report No. 220300360SHA-001
Photos:
281136MW
281136MB
281136MG 281136CH
Overall view
Back view
TRF No. IEC60884_2_3C
99 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 96 of 102 Report No. 220300360SHA-001
Photos:
281113BA 281113BB
281113DS 281113DB
Overall view
Back view
TRF No. IEC60884_2_3C
100 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 97 of 102 Report No. 220300360SHA-001
Photos:
Open view (281136MW)
Internal view (281136MW)
TRF No. IEC60884_2_3C
101 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 98 of 102 Report No. 220300360SHA-001
Photos:
Front view (838143)
Back view (838143)
TRF No. IEC60884_2_3C
102 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 99 of 102 Report No. 220300360SHA-001
Photos:
Open view
Open view (838143)
TRF No. IEC60884_2_3C
103 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 100 of 102 Report No. 220300360SHA-001
Photos:
Internal view (838143)
Front view (618044)
TRF No. IEC60884_2_3C
104 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 101 of 102 Report No. 220300360SHA-001
Photos:
Back view (618044)
Open view (618044)
TRF No. IEC60884_2_3C
105 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 102 of 102 Report No. 220300360SHA-001
Photos:
Internal view (618044)
TRF No. IEC60884_2_3C
106 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Test Report issued under the responsibility of:
TEST REPORT
IEC 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number............................... : 200302028SHA-001
Date of issue .................................. : 2020-05-11, Correction 1: 2021-04-01
Correction 2:2022-09-07
Total number of pages .................. : 86
Name of Testing Laboratory Intertek Testing Services Shanghai
preparing the Report ..................... :
Building No. 86, 1198 Qinzhou Road (North) 200233 Shanghai
CHINA
........................... : Legrand Intelligent Electrical (Huizhou) Co., Ltd.
Address .......................................... : Bldg. B1-B3, East No.39 Hechang 6th Rd., HZZK Hi-tech
Industrical Development Zone, Huizhou, Guangdong, China
Test specification:
Standard ......................................... : IEC 62368-1: 2018
Test procedure............................... : Testing
Non-standard test method ............ : N/A
Test Report Form No. .................... : IEC62368_1C
Test Report Form(s) Originator.... : UL(US)
Master TRF ..................................... : Dated 2019-01-17
Copyright © 2019 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its
Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no
liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage
occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then
only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test results in this report are
relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever
been under an Intertek certification program.
107 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 2 of 86 Report No. 200302028SHA-001
Test item description .......................: Building-in power supply for IT equipment
Trade Mark ........................................: --
Manufacturer.....................................: Same as applicant
Model/Type reference ......................: PYS-16S-050310
Ratings ..............................................: Input: 220-250V~ 50-60Hz Max. 0.3A
Output: 5.0V , 3.0A, 15.0W (in total)
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
Testing Laboratory: Intertek Testing Services Shanghai
Testing location/ address ............................ : Building No.86, 1198 Qinzhou Road (North), 200233
Shanghai, China
Tested by (name, function, signature) ....... : Hans Wang
Approved by (name, function, signature) .. : Will Wang
Testing procedure: CTF Stage 1:
Testing location/ address ............................ :
Tested by (name, function, signature) ....... :
Approved by (name, function, signature) .. :
Testing procedure: CTF Stage 2:
Testing location/ address ............................ :
Tested by (name + signature) ..................... :
Witnessed by (name, function, signature). :
Approved by (name, function, signature) .. :
Testing procedure: CTF Stage 3:
Testing procedure: CTF Stage 4:
Testing location/ address ............................ :
Tested by (name, function, signature) ....... :
Witnessed by (name, function, signature). :
Approved by (name, function, signature) .. :
Supervised by (name, function, signature) :
TRF No. IEC62368_1C
108 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 3 of 86 Report No. 200302028SHA-001
List of Attachments (including a total number of pages in each attachment):
Page 55 63: Photograph, 9 pages in total;
Page 64 86: European group differences and national differences, 23 pages in total.
Summary of testing:
From the result of our examination and tests in the submitted samples, conclude they comply with the
requirements of the standard IEC 62368-1: 2018 and EN 62368-1:2020 + A11:2020.
Tests performed (name of test and test clause): Testing location:
5.2 Classification and limits of electrical energy Intertek Testing Services Shanghai
sources
Building No.86, 1198 Qinzhou Road (North), 200233
5.4.1.4 Maximum operating temperatures for Shanghai, China
materials, components and systems
5.4.1.8 Determination of working voltage
5.4.1.10.3 Ball pressure test
5.4.2 Clearances
5.4.3 Creepage distances
5.4.8 Humidity conditioning
5.4.9 Electric strength test
5.7.2.1 Measurement of touch current
6.2.2.2 Power measurement for worst-case load
fault
6.2.2.3 Power measurement for worst-case source
fault
6.4.3.3 Single Fault Conditions test
6.4.8 Fire enclosure and fire barriers
B.2.5 Input test
B.3.5 Maximum load at output terminals
G.5.3.3 Overload test of Transformers
S.2 Flammability test for fire enclosure and fire
barrier integrity
S.5 Flammability test for fire enclosures and fire
barrier materials
T.2 Steady force test, 10 N
T.5 Steady force test, 250 N
T.8 Impact test
Summary of compliance with National Differences (List of countries addressed):
Group differences for CENELEC are considered.
The product fulfils the requirements of EN 62368-1:2020 + A11:2020.
TRF No. IEC62368_1C
109 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 4 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Copy of marking plate:
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
The product covered by this report is building-in component, with following marking on PCB for identify:
The making plate for the end product shall be checked in end product.
Following marking for USB power supply, including the rating:
5.0V , 3. IT equipment use only or
equivalent are recommended, which should be located near the USB ports.
TRF No. IEC62368_1C
110 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 5 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Test item particulars:
Product group .....................................................: end product built-in component
Classification of use by ......................................: Ordinary person Children likely present
Instructed person
Skilled person
Supply connection...............................................: AC mains DC mains
not mains connected:
ES1 ES2 ES3
Supply tolerance .................................................: +10%/-10%
+20%/-15%
+ %/ - %
None
Supply connection type ..................................: pluggable equipment type A -
non-detachable supply cord
appliance coupler
direct plug-in
pluggable equipment type B -
non-detachable supply cord
appliance coupler
permanent connection
mating connector other: built-in component
Considered current rating of protective 32 A;
device................................................................. : Location: building equipment
N/A
Equipment mobility .......................................... : movable hand-held transportable
direct plug-in stationary for building-in
wall/ceiling-mounted SRME/rack-mounted
other:
Overvoltage category (OVC) ........................... : OVC I OVC II OVC III
OVC IV other:
Class of equipment ......................................... : Class I Class II Class III
Not classified
Special installation location ........................... : N/A restricted access area
outdoor location
Pollution degree (PD) ...................................... : PD 1 PD 2 PD 3
specified Tma........................... : 40 °C Outdoor: minimum °C
IP protection class ........................................... : IPX0 IP___
Power systems ................................................. : TN TT IT - V L-L
not AC mains
Altitude during operation (m) ......................... : 2000 m or less m
Altitude of test laboratory (m) ........................ : 2000 m or less m
Mass of equipment (kg) .................................. : 0.030 kg
TRF No. IEC62368_1C
111 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 6 of 86 Report No. 200302028SHA-001
Possible test case verdicts:
- test case does not apply to the test object ....: N/A
- test object does meet the requirement...........: P (Pass)
- test object does not meet the requirement....: F (Fail)
Testing:
Date of receipt of test item .................................: 2020-03-19
Date (s) of performance of tests ........................: 2020-03-20 to 2020-04-29
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement
uncertainty.
See test report 200302028SHA-002 for test according to IEC/EN 62368-3.
-clause 4.2.5 of IECEE 02:
The application for obtaining a Test Certificate Yes
includes more than one factory location and a
Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ................................................:
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) ................. : Factory 1: Legrand (Beijing) Electrical Co., Ltd
No.4, Chaoqian Road, Changping Kejiyuanqu, Beijing,
China
Factory 2: Legrand Intelligent Electrical (Huizhou) Co.,
Ltd.
Bldg. B1-B3, East No.39 Hechang 6th Rd.,HZZK
Hi-tech Industrial Development Zone, Huizhou,
Guangdong, China
Factory 3: Legrand Electric Ltd
Unit 12 No.1 Industrial Estate Medomsley
Road,Consett County Durham, DH8 6SR
United Kingdom
TRF No. IEC62368_1C
112 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 7 of 86 Report No. 200302028SHA-001
General product information and other remarks:
Product covered by this report is switching mode power supply modules for built in flush mount socket-outlet.
Appropriate use of the module in end product is evaluated with typical model 282443 (End-product report
200302025SHA-001). Loaded with 13A on socket-outlets during temperature test. It may be used for other
appliances with the consideration of the actual product condition.
Dimension of the base box of USB module is about 44 x 36 x 20mm.
To evaluate the appropriate use of USB module in end product, below items shall be double considered in
the end product:
Power rating and identification markings
Electrical insulation of internal wire
Clearances, creepage distances and distances through insulation (The creepage distance and
clearance between primary live part of end-product and output circuit shall be at least 5.5mm)
Temperature measurements (if the most unfavorable condition in end product than typical model, it
shall be double checked.)
Fire enclosure (Shall be 5VA or 5VB material)
Disconnection from the mains supply
Mechanical strength
Humidity conditioning
Electric strength (6000V between primary circuit and external unearthed enclosure)
Touch current test after humidity conditioning
Determination of top, bottom and side openings (No openings on enclosure except openings for USB
port.)
TRF No. IEC62368_1C
113 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 8 of 86 Report No. 200302028SHA-001
OVERVIEW OF ENERGY SOURCES AND SAFEGUARDS
Clause Possible Hazard
5 Electrically-caused injury
Class and Energy Source Body Part Safeguards
(e.g. ES3: Primary circuit) (e.g. Ordinary) B S R
ES1: Internal secondary circuit Ordinary N/A N/A N/A
after T1 sec. output
ES3: Internal primary circuit of Ordinary N/A N/A Enclosure,
built-in power supply transformer,
Y1 Cap.,
clearance to
USB output
6 Electrically-caused fire
Class and Energy Source Material part Safeguards
(e.g. PS2: 100 Watt circuit) (e.g. Printed board) B 1st S 2nd S
PS3: Primary circuit inside the All combustible materials Normal Fire N/A
enclosure within the fire enclosure temperatureenclosure;
fire barrier;
below ignition
temperature Suitable
component
and material
used
PS2: USB output All combustible materials Normal PCB V-0, N/A
within the fire enclosure temperature wire
below ignition insulation and
temperature tubing VW-1,
all other
components
are mounted
on PCB.
7 Injury caused by hazardous substances
Class and Energy Source Body Part Safeguards
(e.g. Ozone) (e.g., Skilled) B S R
N/A N/A N/A N/A N/A
8 Mechanically-caused injury
Class and Energy Source Body Part Safeguards
(e.g. MS3: Plastic fan blades) (e.g. Ordinary) B S R
N/A N/A N/A N/A N/A
9 Thermal burn
Class and Energy Source Body Part Safeguards
(e.g. TS1: Keyboard caps) (e.g., Ordinary) B S R
TS1: Accessible surfaces Ordinary N/A N/A N/A
10 Radiation
Class and Energy Source Body Part Safeguards
TRF No. IEC62368_1C
114 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 9 of 86 Report No. 200302028SHA-001
(e.g. RS1: PMP sound output) (e.g., Ordinary) B S R
N/A N/A N/A N/A N/A
Supplementary Information:
Reinforced Safeguard
TRF No. IEC62368_1C
115 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 10 of 86 Report No. 200302028SHA-001
ENERGY SOURCE DIAGRAM
Optional. Manufacturers are to provide the energy sources diagram identify declared energy sources and
identifying the demarcations are between power sources. Recommend diagram be provided included in
power supply and multipart systems.
Insert diagram below. Example diagram designs are; Block diagrams; image(s) with layered data; mechanical
drawings
ES PS MS TS RS
TRF No. IEC62368_1C
116 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 11 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4 GENERAL REQUIREMENTS P
4.1.1 Acceptance of materials, components and (See appended table 4.1.2) P
subassemblies
4.1.2 Use of components (See appended table 4.1.2) P
4.1.3 Equipment design and construction P
4.1.4 Specified ambient temperature for outdoor use (oC) N/A
.................................................................................... :
4.1.5 Constructions and components not specifically N/A
covered
4.1.8 Liquids and liquid filled components (LFC) (See G.15) N/A
4.1.15 Markings and instructions (See Annex F) N/A
4.4.3 Safeguard robustness P
4.4.3.1 General P
4.4.3.2 Steady force tests (See Clause T.3, T.4, T.5) N/A
4.4.3.3 Drop tests N/A
4.4.3.4 Impact tests On Cover plate. Evaluated in P
end product.
4.4.3.5 Internal accessible safeguard tests N/A
4.4.3.6 Glass impact tests (See Clause T.9, Annex U) N/A
4.4.3.7 Glass fixation tests N/A
Glass impact test (1J) N/A
Push/pull test (10 N) N/A
4.4.3.8 Thermoplastic material tests N/A
4.4.3.9 Air comprising a safeguard P
4.4.3.10 Accessibility, glass, safeguard effectiveness P
4.4.4 Displacement of a safeguard by an insulating liquid N/A
4.4.5 Safety interlocks (See Annex K) N/A
4.5 Explosion P
4.5.1 General (See Annex M for batteries) P
4.5.2 No explosion during normal/abnormal operating (See Clause B.2, B.3) P
condition
No harm by explosion during single fault conditions (See Clause B.4) N/A
4.6 Fixing of conductors P
Fix conductors not to defeat a safeguard P
Compliance is checked by test .............................. : (See Clause T.2) P
Internal wire and components
4.7 Equipment for direct insertion into mains socket outlets N/A
TRF No. IEC62368_1C
117 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 12 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4.7.2 Mains plug part complies with relevant standard .. : N/A
4.7.3 Torque (Nm) .......................................................... : N/A
4.8 Equipment containing coin/button cell batteries N/A
4.8.1 General N/A
4.8.2 Instructional safeguard .......................................... : N/A
4.8.3 Battery compartment door/cover construction N/A
Open torque test N/A
4.8.4.2 Stress relief test N/A
4.8.4.3 Battery replacement test N/A
4.8.4.4 Drop test N/A
4.8.4.5 Impact test N/A
4.8.4.6 Crush test N/A
4.8.5 Compliance N/A
30N force test with test probe N/A
20N force test with test hook N/A
4.9 Likelihood of fire or shock due to entry of conductive object N/A
4.10 Component requirements N/A
4.10.1 Disconnect Device (See Annex L) N/A
4.10.2 Switches and relays (See Annex G) N/A
5 ELECTRICALLY-CAUSED INJURY P
5.2 Classification and limits of electrical energy sources P
5.2.2 ES1, ES2 and ES3 limits P
5.2.2.2 Steady-state voltage and current limits ....................: (See appended table 5.2) P
5.2.2.3 Capacitance limits .....................................................: (See appended table 5.2) P
5.2.2.4 Single pulse limits .....................................................: (See appended table 5.2) N/A
5.2.2.5 Limits for repetitive pulses ........................................: (See appended table 5.2) N/A
5.2.2.6 Ringing signals (See Annex H) N/A
5.2.2.7 Audio signals (See Clause E.1) N/A
5.3 Protection against electrical energy sources P
5.3.1 General Requirements for accessible parts to P
ordinary, instructed and skilled persons
5.3.1 a) Accessible ES1/ES2 derived from ES2/ES3 circuits P
5.3.1 b) Skilled persons not unintentional contact ES3 bare P
conductors
5.3.2.1 Accessibility to electrical energy sources and P
safeguards
TRF No. IEC62368_1C
118 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 13 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Accessibility to outdoor equipment bare parts N/A
5.3.2.2 Contact requirements P
Test with test probe from Annex V -
5.3.2.2 a) Air gap electric strength test potential (V) .............: (See appended table 5.4.9) P
ES3 voltages less than 420 V
peak.
5.3.2.2 b) Air gap distance (mm) ...........................................: N/A
5.3.2.3 Compliance P
5.3.2.4 Terminals for connecting stripped wire No such part. N/A
5.4 Insulation materials and requirements P
5.4.1.2 Properties of insulating material P
5.4.1.3 Material is non-hygroscopic No hygroscopic material. P
5.4.1.4 Maximum operating temperature for insulating Considered to be class 130 (B) P
materials ....................................................................:
5.4.1.5 Pollution degrees ......................................................: Pollution degree 2 P
5.4.1.5.2 Test for pollution degree 1 environment and for an N/A
insulating compound
5.4.1.5.3 Thermal cycling test N/A
5.4.1.6 Insulation in transformers with varying dimensions N/A
5.4.1.7 Insulation in circuits generating starting pulses N/A
5.4.1.8 Determination of working voltage .............................: (See appended table 5.4.1.8) P
5.4.1.9 Insulating surfaces P
5.4.1.10 Thermoplastic parts on which conductive metallic P
parts are directly mounted
5.4.1.10.2 Vicat test....................................................................: (See appended table N/A
5.4.1.10.2)
5.4.1.10.3 Ball pressure test ......................................................: (See appended table P
5.4.1.10.3)
5.4.2 Clearances P
5.4.2.1 General requirements P
Clearances in circuits connected to AC Mains, (See Annex X) P
Alternative method
5.4.2.2 Procedure 1 for determining clearance P
Temporary overvoltage ............................................: 2000V
5.4.2.3 Procedure 2 for determining clearance P
5.4.2.3.2.2 a.c. mains transient voltage ......................................: 4000Vpeak
5.4.2.3.2.3 d.c. mains transient voltage .....................................: N/A
5.4.2.3.2.4 External circuit transient voltage...............................: N/A
TRF No. IEC62368_1C
119 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 14 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.2.3.2.5 Transient voltage determined by measurement ......: N/A
5.4.2.4 Determining the adequacy of a clearance using an (See appended table 5.4.2) N/A
electric strength test .................................................:
5.4.2.5 Multiplication factors for clearances and test voltages Up to 2000m. N/A
...................................................................................:
5.4.2.6 Clearance measurement ..........................................: (See appended table 5.4.2) P
5.4.3 Creepage distances P
5.4.3.1 General P
5.4.3.3 Material group ...........................................................: Material group IIIb is used
5.4.3.4 Creepage distances measurement ..........................: (See appended table 5.4.3) P
5.4.4 Solid insulation P
5.4.4.1 General requirements P
5.4.4.2 Minimum distance through insulation ......................: (See appended table 5.4.4.2) P
5.4.4.3 Insulating compound forming solid insulation N/A
5.4.4.4 Solid insulation in semiconductor devices N/A
5.4.4.5 Insulating compound forming cemented joints N/A
5.4.4.6 Thin sheet material Polyester tape used in the P
transformers.
5.4.4.6.1 General requirements P
5.4.4.6.2 Separable thin sheet material P
Number of layers (pcs) ............................................: 2 P
5.4.4.6.3 Non-separable thin sheet material Triple-insulating winding N/A
Number of layers (pcs) ......................................... : 3 N/A
5.4.4.6.4 Standard test procedure for non-separable thin Approved TIW used N/A
sheet material ........................................................ :
(See appended table 5.4.9)
5.4.4.6.5 Mandrel test N/A
5.4.4.7 Solid insulation in wound components P
5.4.4.9 Solid insulation at frequencies >30 kHz, EP, KR, d, (See appended Table 5.4.4.9) P
VPW (V) ................................................................... :
Alternative by electric strength test, tested voltage (See appended Tables 5.4.4.9 N/A
(V), KR .................................................................... : and 5.4.9)
5.4.5 Antenna terminal insulation N/A
5.4.5.1 General N/A
5.4.5.2 Voltage surge test N/A
5.4.5.3 Insulation resistance (M )..................................... : N/A
Electric strength test .................................................: (See appended table 5.4.9) N/A
5.4.6 Insulation of internal wire as part of supplementary N/A
safeguard
TRF No. IEC62368_1C
120 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 15 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.7 Tests for semiconductor components and for N/A
cemented joints
5.4.8 Humidity conditioning P
Relative humidity (%), temperature (°C), duration 93%, 40°C, 120h
(h) .......................................................................... :
5.4.9 Electric strength test P
5.4.9.1 Test procedure for type test of solid insulation.......: (See appended table 5.4.9) P
5.4.9.2 Test procedure for routine test N/A
5.4.10 Safeguards against transient voltages from external N/A
circuits
5.4.10.1 Parts and circuits separated from external circuits N/A
5.4.10.2 Test methods N/A
5.4.10.2.1 General N/A
5.4.10.2.2 Impulse test ........................................................... : (See appended table 5.4.9) N/A
5.4.10.2.3 Steady-state test.................................................... : (See appended table 5.4.9) N/A
5.4.10.3 Verification for insulation breakdown for impulse N/A
test ......................................................................... :
5.4.11 Separation between external circuits and earth N/A
5.4.11.1 Exceptions to separation between external circuits N/A
and earth
5.4.11.2 Requirements N/A
SPDs bridge separation between external circuit N/A
and earth
Rated operating voltage Uop (V)............................. :
Nominal voltage Upeak (V)....................................... :
Max increase due to variation Usp ........................ :
Max increase due to ageing Usa ......................... :
5.4.11.3 Test method and compliance ................................ : (See appended table 5.4.9) N/A
5.4.12 Insulating liquid N/A
5.4.12.1 General requirements N/A
5.4.12.2 Electric strength of an insulating liquid .................. : (See appended table 5.4.9) N/A
5.4.12.3 Compatibility of an insulating liquid ....................... : (See appended table 5.4.9) N/A
5.4.12.4 Container for insulating liquid ................................ : N/A
5.5 Components as safeguards P
5.5.1 General P
5.5.2 Capacitors and RC units P
5.5.2.1 General requirement P
TRF No. IEC62368_1C
121 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 16 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.5.2.2 Safeguards against capacitor discharge after No X capacitor used. N/A
disconnection of a connector................................. :
(See appended table 5.5.2.2)
5.5.3 Transformers P
5.5.4 Optocouplers (See sub-clause 5.4 or Clause N/A
G.12)
5.5.5 Relays (See sub-clause 5.4) N/A
5.5.6 Resistors (See Clause G.10) N/A
5.5.7 SPDs (See Clause G.8) N/A
5.5.8 Insulation between the mains and an external N/A
circuit consisting of a coaxial cable ....................... :
5.5.9 Safeguards for socket-outlets in outdoor equipment N/A
RCD rated residual operating current (mA) ........... :
5.6 Protective conductor N/A
5.6.2 Requirement for protective conductors Class II construction for USB N/A
module
5.6.2.1 General requirements N/A
5.6.2.2 Colour of insulation N/A
5.6.3 Requirement for protective earthing conductors N/A
Protective earthing conductor size (mm2) .............. :
Protective earthing conductor serving as a N/A
reinforced safeguard
Protective earthing conductor serving as a double N/A
safeguard
5.6.4 Requirements for protective bonding conductors N/A
5.6.4.1 Protective bonding conductors N/A
Protective bonding conductor size (mm2). .............. :
5.6.4.2 Protective current rating (A).................................... : N/A
5.6.5 Terminals for protective conductors N/A
5.6.5.1 Terminal size for connecting protective earthing N/A
conductors (mm).................................................... :
Terminal size for connecting protective bonding N/A
conductors (mm) .......................................................:
5.6.5.2 Corrosion N/A
5.6.6 Resistance of the protective bonding system N/A
5.6.6.1 Requirements N/A
5.6.6.2 Test Method........................................................... : (See appended table 5.6.6) N/A
5.6.6.3 Resistance ( ) or voltage drop.............................. : (See appended table 5.6.6) N/A
TRF No. IEC62368_1C
122 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 17 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.6.7 Reliable connection of a protective earthing N/A
conductor
5.6.8 Functional earthing N/A
Conductor size (mm2)............................................. : N/A
Class II with functional earthing marking .............. : N/A
Appliance inlet cl & cr (mm) ................................... : N/A
5.7 Prospective touch voltage, touch current and protective conductor current P
5.7.2 Measuring devices and networks P
5.7.2.1 Measurement of touch current L/N USB port: P
Max. 0.090mA
L/N Enclosure:
Max. 0.016mA
5.7.2.2 Measurement of voltage N/A
5.7.3 Equipment set-up, supply connections and earth P
connections
5.7.4 Unearthed accessible parts ................................... : (See appended table 5.7.4) N/A
5.7.5 Earthed accessible conductive parts ..................... : (See appended table 5.7.5) N/A
5.7.6 Requirements when touch current exceeds ES2 N/A
limits
Protective conductor current (mA)......................... : N/A
Instructional Safeguard.......................................... : N/A
5.7.7 Prospective touch voltage and touch current N/A
associated with external circuits
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current N/A
associated with paired conductor cables
5.7.8 Summation of touch currents from external circuits N/A
a) Equipment connected to earthed external N/A
circuits, current (mA) ............................................. :
b) Equipment connected to unearthed external N/A
circuits, current (mA) ............................................. :
5.8 Backfeed safeguard in battery backed up supplies N/A
Mains terminal ES .....................................................: (See appended table 5.8) N/A
Air gap (mm)..............................................................: N/A
6 ELECTRICALLY- CAUSED FIRE P
6.2 Classification of PS and PIS P
6.2.2 Power source circuit classifications ..........................: (See appended table 6.2.2) P
TRF No. IEC62368_1C
123 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 18 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................................................: Soldering connections on PCB P
in primary circuit are
considered as arcing PIS.
(See appended table 6.2.3.1)
6.2.3.2 Resistive PIS ............................................................: Primary circuits inside the P
enclosure.
(See appended table 6.2.3.2)
6.3 Safeguards against fire under normal operating and abnormal operating P
conditions
6.3.1 No ignition and attainable temperature value less (See appended table B.1.5 and P
than 90 % defined by ISO 871 or less than 300 C B.3)
for unknown materials ........................................... :
Combustible materials outside fire enclosure ..........: N/A
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard method P
is used
6.4.2 Reduction of the likelihood of ignition under single N/A
fault conditions in PS1 circuits
6.4.3 Reduction of the likelihood of ignition under single N/A
fault conditions in PS2 and PS3 circuits
6.4.3.1 Supplementary safeguards N/A
6.4.3.2 Single Fault Conditions .......................................... : (See appended table B.4) N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits N/A
6.4.5 Control of fire spread in PS2 circuits P
6.4.5.2 Supplementary safeguards N/A
6.4.6 Control of fire spread in PS3 circuits P
6.4.7 Separation of combustible materials from a PIS All internal power sources are N/A
enclosed by fire enclosure.
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a fire barrier N/A
6.4.8 Fire enclosures and fire barriers P
6.4.8.2 Fire enclosure and fire barrier material properties P
6.4.8.2.1 Requirements for a fire barrier N/A
6.4.8.2.2 Requirements for a fire enclosure Tested according to Annex S P
(See appended tables 4.1.2)
6.4.8.3 Constructional requirements for a fire enclosure P
and a fire barrier
TRF No. IEC62368_1C
124 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 19 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.4.8.3.1 Fire enclosure and fire barrier openings No opening except USB ports. P
Need double check if the USB
module is incorporated into
other models of socket outlet.
6.4.8.3.2 Fire barrier dimensions N/A
6.4.8.3.3 Top openings and properties N/A
Openings dimensions (mm)................................... : N/A
6.4.8.3.4 Bottom openings and properties N/A
Openings dimensions (mm)................................... : N/A
Flammability tests for the bottom of a fire enclosure (See Clause S.3) N/A
Instructional Safeguard .............................................: N/A
6.4.8.3.5 Side openings and properties N/A
Openings dimensions (mm)................................... : N/A
6.4.8.3.6 Integrity of a fire enclosure, condition met: a), b) or Need double check if the USB N/A
c)............................................................................ : module is incorporated into
other models of socket outlet.
6.4.8.4 Separation of a PIS from a fire enclosure and a fire Tested according to Annex S P
barrier distance (mm) or flammability rating .......... :
6.4.9 Flammability of insulating liquid...............................: N/A
6.5 Internal and external wiring P
6.5.1 General requirements Evaluated per IEC/EN 60950-1 P
based on Cl. 4.1.1
6.5.2 Requirements for interconnection to building wiring N/A
............................................................................... :
6.5.3 Internal wiring size (mm2) for socket-outlets.......... : N/A
6.6 Safeguards against fire due to the connection to additional equipment P
7 INJURY CAUSED BY HAZARDOUS SUBSTANCES N/A
7.2 Reduction of exposure to hazardous substances N/A
7.3 Ozone exposure N/A
7.4 Use of personal safeguards or personal protective equipment (PPE) N/A
Personal safeguards and instructions ................... :
7.5 Use of instructional safeguards and instructions N/A
Instructional safeguard (ISO 7010)........................ :
7.6 Batteries and their protection circuits N/A
8 MECHANICALLY-CAUSED INJURY N/A
8.2 Mechanical energy source classifications N/A
TRF No. IEC62368_1C
125 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 20 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8.3 Safeguards against mechanical energy sources N/A
8.4 Safeguards against parts with sharp edges and corners N/A
8.4.1 Safeguards N/A
Instructional Safeguard .............................................: N/A
8.4.2 Sharp edges or corners N/A
8.5 Safeguards against moving parts N/A
8.5.1 Fingers, jewellery, clothing, hair, etc., contact with N/A
MS2 or MS3 parts
MS2 or MS3 part required to be accessible for the N/A
function of the equipment
Moving MS3 parts only accessible to skilled person N/A
8.5.2 Instructional safeguard..............................................: No moving parts N/A
8.5.4 Special categories of equipment containing moving N/A
parts
8.5.4.1 General N/A
8.5.4.2 Equipment containing work cells with MS3 parts N/A
8.5.4.2.1 Protection of persons in the work cell N/A
8.5.4.2.2 Access protection override N/A
8.5.4.2.2.1 Override system N/A
8.5.4.2.2.2 Visual indicator N/A
8.5.4.2.3 Emergency stop system N/A
Maximum stopping distance from the point of N/A
activation (m).............................................................:
Space between end point and nearest fixed N/A
mechanical part (mm) ...............................................:
8.5.4.2.4 Endurance requirements N/A
Mechanical system subjected to 100 000 cycles of N/A
operation
- Mechanical function check and visual inspection N/A
- Cable assembly ......................................................: N/A
8.5.4.3 Equipment having electromechanical device for N/A
destruction of media
8.5.4.3.1 Equipment safeguards N/A
8.5.4.3.2 Instructional safeguards against moving parts ........: N/A
8.5.4.3.3 Disconnection from the supply N/A
8.5.4.3.4 Cut type and test force (N)........................................: N/A
8.5.4.3.5 Compliance N/A
8.5.5 High pressure lamps N/A
TRF No. IEC62368_1C
126 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 21 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Explosion test ............................................................: N/A
8.5.5.3 Glass particles dimensions (mm) .............................: N/A
8.6 Stability of equipment N/A
8.6.1 General N/A
Instructional safeguard..............................................: N/A
8.6.2 Static stability N/A
8.6.2.2 Static stability test .....................................................: N/A
8.6.2.3 Downward force test N/A
8.6.3 Relocation stability N/A
Wheels diameter (mm) .............................................:
Tilt test N/A
8.6.4 Glass slide test N/A
8.6.5 Horizontal force test ..................................................: N/A
8.7 Equipment mounted to wall, ceiling or other structure N/A
8.7.1 Mount means type ....................................................: N/A
8.7.2 Test methods N/A
Test 1, additional downwards force (N)....................: N/A
Test 2, number of attachment points and test force N/A
(N)..............................................................................:
Test 3 Nominal diameter (mm) and applied torque N/A
(Nm)...........................................................................:
8.8 Handles strength N/A
8.8.1 General N/A
8.8.2 Handle strength test N/A
Number of handles....................................................:
Force applied (N) ......................................................:
8.9 Wheels or casters attachment requirements N/A
8.9.2 Pull test N/A
8.10 Carts, stands and similar carriers N/A
8.10.1 General N/A
8.10.2 Marking and instructions...........................................: N/A
8.10.3 Cart, stand or carrier loading test N/A
Loading force applied (N) .........................................: N/A
8.10.4 Cart, stand or carrier impact test N/A
8.10.5 Mechanical stability N/A
Force applied (N) ......................................................:
TRF No. IEC62368_1C
127 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 22 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8.10.6 Thermoplastic temperature stability N/A
8.11 Mounting means for slide-rail mounted equipment (SRME) N/A
8.11.1 General N/A
8.11.2 Requirements for slide rails N/A
Instructional Safeguard .............................................: N/A
8.11.3 Mechanical strength test N/A
8.11.3.1 Downward force test, force (N) applied....................: N/A
8.11.3.2 Lateral push force test N/A
8.11.3.3 Integrity of slide rail end stops N/A
8.11.4 Compliance N/A
8.12 Telescoping or rod antennas N/A
Button/ball diameter (mm) ........................................:
9 THERMAL BURN INJURY P
9.2 Thermal energy source classifications P
9.3 Touch temperature limits P
9.3.1 Touch temperatures of accessible parts ..................: TS1 for accessible surfaces. P
Need double evaluated in end
product.
(See appended table)
9.3.2 Test method and compliance N/A
9.4 Safeguards against thermal energy sources N/A
9.5 Requirements for safeguards N/A
9.5.1 Equipment safeguard N/A
9.5.2 Instructional safeguard..............................................: N/A
9.6 Requirements for wireless power transmitters N/A
9.6.1 General N/A
9.6.2 Specification of the foreign objects N/A
9.6.3 Test method and compliance ...................................: (See appended table 9.6) N/A
10 RADIATION N/A
10.2 Radiation energy source classification N/A
10.2.1 General classification N/A
Lasers .................................................................... :
Lamps and lamp systems ...................................... :
Image projectors .................................................... :
TRF No. IEC62368_1C
128 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 23 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
X-Ray..................................................................... :
Personal music player ........................................... :
10.3 Safeguards against laser radiation N/A
The standard(s) equipment containing laser(s) N/A
comply .......................................................................:
10.4 Safeguards against optical radiation from lamps and lamp systems (including N/A
LED types)
10.4.1 General requirements N/A
Instructional safeguard provided for accessible N/A
radiation level needs to exceed
Risk group marking and location ..............................: N/A
Information for safe operation and installation N/A
10.4.2 Requirements for enclosures N/A
UV radiation exposure ..............................................: (See Annex C) N/A
10.4.3 Instructional safeguard .......................................... : N/A
10.5 Safeguards against X-radiation N/A
10.5.1 Requirements N/A
Instructional safeguard for skilled persons ............ :
10.5.3 Maximum radiation (pA/kg).................................... : (See appended tables B.3 &
B.4)
10.6 Safeguards against acoustic energy sources N/A
10.6.1 General N/A
10.6.2 Classification N/A
Acoustic output LAeq,T, dB(A).....................................: N/A
Unweighted RMS output voltage (mV).....................: N/A
Digital output signal (dBFS) ......................................: N/A
10.6.3 Requirements for dose-based systems N/A
10.6.3.1 General requirements N/A
10.6.3.2 Dose-based warning and automatic decrease N/A
10.6.3.3 Exposure-based warning and requirements N/A
30 s integrated exposure level (MEL30) ..................: N/A
..................................: N/A
10.6.4 Measurement methods N/A
10.6.5 Protection of persons N/A
Instructional safeguards ........................................ : N/A
10.6.6 Requirements for listening devices (headphones, N/A
earphones, etc.)
TRF No. IEC62368_1C
129 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 24 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
10.6.6.1 Corded listening devices with analogue input N/A
Listening device input voltage (mV)....................... : N/A
10.6.6.2 Corded listening devices with digital input N/A
Max. acoustic output LAeq,T, dB(A) ............................: N/A
10.6.6.3 Cordless listening devices N/A
Max. acoustic output LAeq,T, dB(A) ............................: N/A
NORMAL OPERATING CONDITION TESTS, ABNORMAL OPERATING P
B
CONDITION TESTS AND SINGLE FAULT CONDITION TESTS
B.1 General P
B.1.5 Temperature measurement conditions (See appended table B.1.5) P
B.2 Normal operating conditions P
B.2.1 General requirements ............................................ : (See Test Item Particulars and P
appended test tables)
Audio Amplifiers and equipment with audio (See Annex E) N/A
amplifiers ............................................................... :
B.2.3 Supply voltage and tolerances P
B.2.5 Input test ................................................................ : (See appended table B.2.5) P
B.3 Simulated abnormal operating conditions P
B.3.1 General P
B.3.2 Covering of ventilation openings N/A
Instructional safeguard .......................................... : N/A
B.3.3 DC mains polarity test N/A
B.3.4 Setting of voltage selector No such parts N/A
B.3.5 Maximum load at output terminals (See appended table B.3) P
B.3.6 Reverse battery polarity N/A
B.3.7 Audio amplifier abnormal operating conditions N/A
B.3.8 Safeguards functional during and after abnormal (See appended table B.3) P
operating conditions .............................................. :
B.4 Simulated single fault conditions P
B.4.1 General P
B.4.2 Temperature controlling device N/A
B.4.3 Blocked motor test N/A
B.4.4 Functional insulation (See appended table B.4) P
B.4.4.1 Short circuit of clearances for functional insulation P
B.4.4.2 Short circuit of creepage distances for functional P
insulation
TRF No. IEC62368_1C
130 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 25 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.4.4.3 Short circuit of functional insulation on coated N/A
printed boards
B.4.5 Short-circuit and interruption of electrodes in tubes P
and semiconductors
B.4.6 Short circuit or disconnection of passive P
components
B.4.7 Continuous operation of components N/A
B.4.8 Compliance during and after single fault conditions (See appended table B.4) P
............................................................................... :
B.4.9 Battery charging and discharging under single fault (See Annex M) N/A
conditions
C UV RADIATION N/A
C.1 Protection of materials in equipment from UV radiation N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test N/A
C.2.1 Test apparatus....................................................... : N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon-arc light-exposure test N/A
C.2.4 Xenon-arc light-exposure test N/A
D TEST GENERATORS N/A
D.1 Impulse test generators N/A
D.2 Antenna interface test generator N/A
D.3 Electronic pulse generator N/A
E TEST CONDITIONS FOR EQUIPMENT CONTAINING AUDIO AMPLIFIERS N/A
E.1 Electrical energy source classification for audio signals N/A
Maximum non-clipped output power (W)............... :
.................................... :
Open-circuit output voltage (V).............................. :
Instructional safeguard .......................................... : See Clause F.5
E.2 Audio amplifier normal operating conditions N/A
Audio signal source type ....................................... :
Audio output power (W) ......................................... :
Audio output voltage (V) ........................................ :
.................................... :
Requirements for temperature measurement (See Table B.1.5) N/A
E.3 Audio amplifier abnormal operating conditions (See Table B.3, B.4) N/A
TRF No. IEC62368_1C
131 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 26 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
F EQUIPMENT MARKINGS, INSTRUCTIONS, AND INSTRUCTIONAL N/A
SAFEGUARDS
F.1 General N/A
Language .............................................................. :
F.2 Letter symbols and graphical symbols N/A
F.2.1 Letter symbols according to IEC60027-1 N/A
F.2.2 Graphic symbols according to IEC, ISO or N/A
manufacturer specific
F.3 Equipment markings N/A
F.3.1 Equipment marking locations N/A
F.3.2 Equipment identification markings N/A
F.3.2.1 Manufacturer identification ................................... : N/A
F.3.2.2 Model identification ............................................... : N/A
F.3.3 Equipment rating markings N/A
F.3.3.1 Equipment with direct connection to mains N/A
F.3.3.2 Equipment without direct connection to mains N/A
F.3.3.3 Nature of the supply voltage .................................. : N/A
F.3.3.4 Rated voltage......................................................... : N/A
F.3.3.5 Rated frequency .................................................... : N/A
F.3.3.6 Rated current or rated power................................. : N/A
F.3.3.7 Equipment with multiple supply connections N/A
F.3.4 Voltage setting device N/A
F.3.5 Terminals and operating devices N/A
F.3.5.1 Mains appliance outlet and socket-outlet markings N/A
............................................................................... :
F.3.5.2 Switch position identification marking.................... : N/A
F.3.5.3 Replacement fuse identification and rating markings N/A
............................................................................... :
Instructional safeguards for neutral fuse ............... : N/A
F.3.5.4 Replacement battery identification marking .......... : N/A
F.3.5.5 Neutral conductor terminal N/A
F.3.5.6 Terminal marking location N/A
F.3.6 Equipment markings related to equipment N/A
classification
F.3.6.1 Class I equipment N/A
F.3.6.1.1 Protective earthing conductor terminal .................. : N/A
F.3.6.1.2 Protective bonding conductor terminals ............... : N/A
TRF No. IEC62368_1C
132 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 27 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
F.3.6.2 Equipment class marking ...................................... : N/A
F.3.6.3 Functional earthing terminal marking .................... : N/A
F.3.7 Equipment IP rating marking ................................. : N/A
F.3.8 External power supply output marking .................. : N/A
F.3.9 Durability, legibility and permanence of marking N/A
F.3.10 Test for permanence of markings N/A
F.4 Instructions N/A
a)................................................................................In N/A
formation prior to installation and initial use
b)................................................................................E N/A
quipment for use in locations where children not
likely to be present
c)................................................................................ N/A
Instructions for installation and interconnection
d)................................................................................ N/A
Equipment intended for use only in restricted
access area
e)................................................................................ N/A
Equipment intended to be fastened in place
f)................................................................................. N/A
Instructions for audio equipment terminals
g)................................................................................ N/A
Protective earthing used as a safeguard
h)................................................................................ N/A
Protective conductor current exceeding ES2
limits
i) ................................................................................. N/A
Graphic symbols used on equipment
j)................................................................................. N/A
Permanently connected equipment not provided
with all-pole mains switch
k)................................................................................ N/A
Replaceable components or modules providing
safeguard function
l) ................................................................................. N/A
Equipment containing insulating liquid
m)............................................................................... N/A
Installation instructions for outdoor equipment
F.5 Instructional safeguards N/A
G COMPONENTS P
G.1 Switches N/A
G.1.1 General N/A
TRF No. IEC62368_1C
133 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 28 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.1.3 Test method and compliance N/A
G.2 Relays N/A
G.2.1 Requirements N/A
G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supplying power to N/A
other equipment
G.2.4 Test method and compliance N/A
G.3 Protective devices N/A
G.3.1 Thermal cut-offs N/A
Thermal cut-outs separately approved according to N/A
IEC 60730 with conditions indicated in a) & b)
Thermal cut-outs tested as part of the equipment as N/A
indicated in c)
G.3.1.2 Test method and compliance N/A
G.3.2 Thermal links N/A
G.3.2.1 a) Thermal links tested separately according to IEC N/A
60691 with specifics
b) Thermal links tested as part of the equipment N/A
G.3.2.2 Test method and compliance N/A
G.3.3 PTC thermistors N/A
G.3.4 Overcurrent protection devices N/A
G.3.5 Safeguards components not mentioned in G.3.1 to P
G.3.4
G.3.5.1 Non-resettable devices suitably rated and marking P
provided
G.3.5.2 Single faults conditions .......................................... : (See appended table B.4) P
G.4 Connectors N/A
G.4.1 Spacings N/A
G.4.2 Mains connector configuration............................... : N/A
G.4.3 Plug is shaped that insertion into mains socket- N/A
outlets or appliance coupler is unlikely
G.5 Wound components P
G.5.1 Wire insulation in wound components P
G.5.1.2 Protection against mechanical stress separation with tape provided P
G.5.2 Endurance test N/A
G.5.2.1 General test requirements N/A
G.5.2.2 Heat run test ......................................................... N/A
TRF No. IEC62368_1C
134 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 29 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Test time (days per cycle) ..................................... :
Test temperature ( C) ............................................ :
G.5.2.3 Wound components supplied from the mains N/A
G.5.2.4 No insulation breakdown N/A
G.5.3 Transformers P
G.5.3.1 Compliance method............................................... : Meet the requirement in P
G.5.3.2 and G.5.3.3
Position .................................................................. : Used in a low-voltage power P
supply
Method of protection .............................................. : Non-inherently short-circuit P
proof transformers protected
by electronic circuit
G.5.3.2 Insulation P
Protection from displacement of windings ............. : The end turns are reliably
fixed by tape, the whole
transformer varnished
G.5.3.3 Transformer overload tests (See appended table B.3) P
G.5.3.3.1 Test conditions P
G.5.3.3.2 Winding temperatures P
G.5.3.3.3 Winding temperatures - alternative test method N/A
G.5.3.4 Transformers using FIW N/A
G.5.3.4.1 General N/A
FIW wire nominal diameter .................................... :
G.5.3.4.2 Transformers with basic insulation only N/A
G.5.3.4.3 Transformers with double insulation or reinforced N/A
insulation................................................................ :
G.5.3.4.4 Transformers with FIW wound on metal or ferrite N/A
core
G.5.3.4.5 Thermal cycling test and compliance N/A
G.5.3.4.6 Partial discharge test N/A
G.5.3.4.7 Routine test N/A
G.5.4 Motors N/A
G.5.4.1 General requirements N/A
G.5.4.2 Motor overload test conditions N/A
G.5.4.3 Running overload test N/A
G.5.4.4.2 Locked-rotor overload test N/A
Test duration (days) .............................................. :
G.5.4.5 Running overload test for DC motors N/A
TRF No. IEC62368_1C
135 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 30 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.5.4.5.2 Tested in the unit N/A
G.5.4.5.3 Alternative method N/A
G.5.4.6 Locked-rotor overload test for DC motors N/A
G.5.4.6.2 Tested in the unit N/A
Maximum Temperature ........................................ : N/A
G.5.4.6.3 Alternative method N/A
G.5.4.7 Motors with capacitors N/A
G.5.4.8 Three-phase motors N/A
G.5.4.9 Series motors N/A
Operating voltage ................................................. :
G.6 Wire Insulation P
G.6.1 General Certified TIW is used as P
secondary winding.
G.6.2 Enamelled winding wire insulation N/A
G.7 Mains supply cords N/A
G.7.1 General requirements N/A
Type ....................................................................... :
G.7.2 Cross sectional area (mm2 or AWG) ..................... : N/A
G.7.3 Cord anchorages and strain relief for non- N/A
detachable power supply cords
G.7.3.2 Cord strain relief N/A
G.7.3.2.1 Requirements N/A
Strain relief test force (N)....................................... : N/A
G.7.3.2.2 Strain relief mechanism failure N/A
G.7.3.2.3 Cord sheath or jacket position, distance (mm) ...... : N/A
G.7.3.2.4 Strain relief and cord anchorage material N/A
G.7.4 Cord Entry N/A
G.7.5 Non-detachable cord bend protection N/A
G.7.5.1 Requirements N/A
G.7.5.2 Test method and compliance N/A
Overall diameter or minor overall dimension, D
(mm) ...................................................................... :
Radius of curvature after test (mm) ....................... :
G.7.6 Supply wiring space N/A
G.7.6.1 General requirements N/A
G.7.6.2 Stranded wire N/A
G.7.6.2.1 Requirements N/A
TRF No. IEC62368_1C
136 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 31 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.7.6.2.2 Test with 8 mm strand N/A
G.8 Varistors N/A
G.8.1 General requirements N/A
G.8.2 Safeguards against fire N/A
G.8.2.1 General N/A
G.8.2.2 Varistor overload test N/A
G.8.2.3 Temporary overvoltage test N/A
G.9 Integrated circuit (IC) current limiters N/A
G.9.1 Requirements N/A
IC limiter output current (max. 5A)......................... :
.................................. :
G.9.2 Test Program N/A
G.9.3 Compliance N/A
G.10 Resistors N/A
G.10.1 General N/A
G.10.2 Conditioning N/A
G.10.3 Resistor test N/A
G.10.4 Voltage surge test N/A
G.10.5 Impulse test N/A
G.10.6 Overload test N/A
G.11 Capacitors and RC units P
G.11.1 General requirements Y1 capacitors between Pri. P
and Sec. circuit.
G.11.2 Conditioning of capacitors and RC units P
G.11.3 Rules for selecting capacitors P
G.12 Optocouplers N/A
Optocouplers comply with IEC 60747-5-5 with N/A
specifics
Type test voltage Vini,a............................................ :
Routine test voltage, Vini, b ..................................... :
G.13 Printed boards P
G.13.1 General requirements P
G.13.2 Uncoated printed boards N/A
G.13.3 Coated printed boards N/A
G.13.4 Insulation between conductors on the same inner N/A
surface
G.13.5 Insulation between conductors on different surfaces P
TRF No. IEC62368_1C
137 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 32 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Distance through insulation ................................... : (see appended table 4.1.2) P
Number of insulation layers (pcs) ......................... :
G.13.6 Tests on coated printed boards N/A
G.13.6.1 Sample preparation and preliminary inspection N/A
G.13.6.2 Test method and compliance N/A
G.14 Coating on components terminals N/A
G.14.1 Requirements ....................................................... : (See Clause G.13) N/A
G.15 Pressurized liquid filled components N/A
G.15.1 Requirements N/A
G.15.2 Test methods and compliance N/A
G.15.2.1 Hydrostatic pressure test N/A
G.15.2.2 Creep resistance test N/A
G.15.2.3 Tubing and fittings compatibility test N/A
G.15.2.4 Vibration test N/A
G.15.2.5 Thermal cycling test N/A
G.15.2.6 Force test N/A
G.15.3 Compliance N/A
G.16 IC including capacitor discharge function (ICX) N/A
G.16.1 Condition for fault tested is not required N/A
ICX with associated circuitry tested in equipment N/A
ICX tested separately N/A
G.16.2 Tests N/A
Smallest capacitance and smallest resistance
specified by ICX manufacturer for impulse test ..... :
Mains voltage that impulses to be superimposed on
............................................................................... :
Largest capacitance and smallest resistance for
ICX tested by itself for 10000 cycles test .............. :
G.16.3 Capacitor discharge test ........................................ : N/A
H CRITERIA FOR TELEPHONE RINGING SIGNALS N/A
H.1 General N/A
H.2 Method A N/A
H.3 Method B N/A
H.3.1 Ringing signal N/A
H.3.1.1 Frequency (Hz) ..................................................... :
H.3.1.2 Voltage (V) ............................................................ :
H.3.1.3 Cadence; time (s) and voltage (V) ........................ :
TRF No. IEC62368_1C
138 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 33 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
H.3.1.4 Single fault current (mA): ....................................... :
H.3.2 Tripping device and monitoring voltage N/A
H.3.2.1 Conditions for use of a tripping device or a N/A
monitoring voltage
H.3.2.2 Tripping device N/A
H.3.2.3 Monitoring voltage (V) ........................................... : N/A
J INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED P
INSULATION
J.1 General P
Winding wire insulation .......................................... : Certified TIW used.
Reinforced insulation
Solid round winding wire, diameter (mm) .............. : Solid round Ø0.50mm P
Solid square and rectangular (flatwise bending) N/A
winding wire, cross-sectional area (mm2).............. :
J.2/J.3 Tests and Manufacturing (See separate test report)
K SAFETY INTERLOCKS N/A
K.1 General requirements N/A
Instructional safeguard .......................................... : N/A
K.2 Components of safety interlock safeguard mechanism N/A
K.3 Inadvertent change of operating mode N/A
K.4 Interlock safeguard override N/A
K.5 Fail-safe N/A
K.5.1 Under single fault condition N/A
K.6 Mechanically operated safety interlocks N/A
K.6.1 Endurance requirement N/A
K.6.2 Test method and compliance ................................ : N/A
K.7 Interlock circuit isolation N/A
K.7.1 Separation distance for contact gaps & interlock N/A
circuit elements
In circuit connected to mains, separation distance N/A
for contact gaps (mm)............................................ :
In circuit isolated from mains, separation distance N/A
for contact gaps (mm)............................................ :
Electric strength test before and after the test of (See appended table 5.4.9) N/A
K.7.2 ...................................................................... :
K.7.2 Overload test, Current (A) ..................................... : N/A
K.7.3 Endurance test N/A
K.7.4 Electric strength test N/A
TRF No. IEC62368_1C
139 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 34 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
L DISCONNECT DEVICES N/A
L.1 General requirements Building-in type, should be N/A
evaluated in end product.
L.2 Permanently connected equipment N/A
L.3 Parts that remain energized N/A
L.4 Single-phase equipment N/A
L.5 Three-phase equipment N/A
L.6 Switches as disconnect devices N/A
L.7 Plugs as disconnect devices N/A
L.8 Multiple power sources N/A
Instructional safeguard .......................................... : N/A
M EQUIPMENT CONTAINING BATTERIES AND THEIR PROTECTION CIRCUITS N/A
M.1 General requirements N/A
M.2 Safety of batteries and their cells N/A
M.2.1 Batteries and their cells comply with relevant IEC N/A
standards ............................................................... :
M.3 Protection circuits for batteries provided within N/A
the equipment
M.3.1 Requirements N/A
M.3.2 Test method N/A
Overcharging of a rechargeable battery N/A
Excessive discharging N/A
Unintentional charging of a non-rechargeable N/A
battery
Reverse charging of a rechargeable battery N/A
M.3.3 Compliance (See appended table M.3) N/A
M.4 Additional safeguards for equipment containing a portable secondary lithium N/A
battery
M.4.1 General N/A
M.4.2 Charging safeguards N/A
M.4.2.1 Requirements N/A
M.4.2.2 Compliance............................................................ : (See appended table M.4.2) N/A
M.4.3 Fire enclosure ........................................................ : N/A
M.4.4 Drop test of equipment containing a secondary N/A
lithium battery
M.4.4.2 Preparation and procedure for the drop test N/A
M.4.4.3 Drop, Voltage on reference and dropped batteries N/A
(V); voltage difference during 24 h period (%): ..... :
TRF No. IEC62368_1C
140 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 35 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
M.4.4.4 Check of the charge/discharge function N/A
M.4.4.5 Charge / discharge cycle test N/A
M.4.4.6 Compliance N/A
M.5 Risk of burn due to short-circuit during carrying N/A
M.5.1 Requirement N/A
M.5.2 Test method and compliance N/A
M.6 Safeguards against short-circuits N/A
M.6.1 External and internal faults N/A
M.6.2 Compliance N/A
M.7 Risk of explosion from lead acid and NiCd batteries N/A
M.7.1 Ventilation preventing explosive gas concentration N/A
Calculated hydrogen generation rate .................... : N/A
M.7.2 Test method and compliance N/A
Minimum air flow rate, Q (m3/h) ............................. : N/A
M.7.3 Ventilation tests N/A
M.7.3.1 General N/A
M.7.3.2 Ventilation test alternative 1 N/A
Hydrogen gas concentration (%) ........................... : N/A
M.7.3.3 Ventilation test alternative 2 N/A
Obtained hydrogen generation rate....................... : N/A
M.7.3.4 Ventilation test alternative 3 N/A
Hydrogen gas concentration (%) ........................... : N/A
M.7.4 Marking .................................................................. : N/A
M.8 Protection against internal ignition from external spark sources of batteries N/A
with aqueous electrolyte
M.8.1 General N/A
M.8.2 Test method N/A
M.8.2.1 General N/A
M.8.2.2 Estimation of hypothetical volume VZ (m3/s).......... :
M.8.2.3 Correction factors .................................................. :
M.8.2.4 Calculation of distance d (mm) ............................. :
M.9 Preventing electrolyte spillage N/A
M.9.1 Protection from electrolyte spillage N/A
M.9.2 Tray for preventing electrolyte spillage N/A
M.10 Instructions to prevent reasonably foreseeable N/A
misuse
TRF No. IEC62368_1C
141 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 36 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Instructional safeguard .......................................... : N/A
N ELECTROCHEMICAL POTENTIALS N/A
Material(s) used ..................................................... :
O MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES P
Value of X (mm)..................................................... : 1mm
P SAFEGUARDS AGAINST CONDUCTIVE OBJECTS P
P.1 General P
P.2 Safeguards against entry or consequences of entry of a foreign object P
P.2.1 General P
P.2.2 Safeguards against entry of a foreign object P
Location and Dimensions (mm) ............................ : USB port after mount.
P.2.3 Safeguards against the consequences of entry of a N/A
foreign object
P.2.3.1 Safeguard requirements N/A
The ES3 and PS3 keep-out volume in Figure P.3 N/A
not applicable to transportable equipment
Transportable equipment with metalized plastic N/A
parts ....................................................................... :
P.2.3.2 Consequence of entry test..................................... : N/A
P.3 Safeguards against spillage of internal liquids N/A
P.3.1 General N/A
P.3.2 Determination of spillage consequences N/A
P.3.3 Spillage safeguards N/A
P.3.4 Compliance N/A
P.4 Metallized coatings and adhesives securing parts N/A
P.4.1 General N/A
P.4.2 Tests N/A
Conditioning, TC (°C) ............................................. :
Duration (weeks).................................................... :
Q CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING N/A
Q.1 Limited power sources N/A
Q.1.1 Requirements N/A
a) Inherently limited output N/A
b) Impedance limited output N/A
c) Regulating network limited output N/A
d) Overcurrent protective device limited output N/A
e) IC current limiter complying with G.9 N/A
TRF No. IEC62368_1C
142 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 37 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Q.1.2 Test method and compliance ................................ : (See appended table Q.1) N/A
Current rating of overcurrent protective device (A) N/A
............................................................................... :
Q.2 Test for external circuits paired conductor N/A
cable
Maximum output current (A) ................................. : N/A
Current limiting method ......................................... :
R LIMITED SHORT CIRCUIT TEST N/A
R.1 General N/A
R.2 Test setup N/A
Overcurrent protective device for test.................... :
R.3 Test method N/A
Cord/cable used for test ........................................ :
R.4 Compliance N/A
S TESTS FOR RESISTANCE TO HEAT AND FIRE P
S.1 Flammability test for fire enclosures and fire barrier materials of equipment N/A
where the steady state power does not exceed 4 000 W
Samples, material .................................................. :
Wall thickness (mm) .............................................. :
Conditioning ( C) ................................................... :
Test flame according to IEC 60695-11-5 with N/A
conditions as set out
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/A
S.2 Flammability test for fire enclosure and fire barrier integrity P
Samples, material .................................................. : Cover plate, base
Wall thickness (mm) .............................................. : 1.5mm
Conditioning ( C) ................................................... : 70
S.3 Flammability test for the bottom of a fire enclosure N/A
S.3.1 Mounting of samples N/A
S.3.2 Test method and compliance N/A
Mounting of samples ............................................ :
Wall thickness (mm) .............................................. :
S.4 Flammability classification of materials N/A
S.5 Flammability test for fire enclosures and fire barrier materials of equipment P
where the steady state power exceeding 4 000 W
TRF No. IEC62368_1C
143 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 38 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Samples, material .................................................. : Cover plate, base
Wall thickness (mm) .............................................. : 1.5mm
Conditioning ( C) ................................................... : 70
T MECHANICAL STRENGTH TESTS P
T.1 General P
T.2 Steady force test, 10 N ....................................... : (See appended table T.2) P
T.3 Steady force test, 30 N ....................................... : (See appended table T.3) N/A
T.4 Steady force test, 100 N ..................................... : (See appended table T.4) N/A
T.5 Steady force test, 250 N ..................................... : (See appended table T.5) P
Should be double evaluated in
end product.
T.6 Enclosure impact test (See appended table T.6) P
Fall test N/A
Swing test Cover plate. P
Should be double evaluated in
end product.
T.7 Drop test .............................................................. : (See appended table T.7) N/A
T.8 Stress relief test................................................... : (See appended table T.8) P
Should be double evaluated in
end product.
T.9 Glass Impact Test ...................................................: (See appended table T.9) N/A
T.10 Glass fragmentation test N/A
Number of particles counted.....................................: N/A
T.11 Test for telescoping or rod antennas N/A
Torque value (Nm) ................................................ : N/A
U MECHANICAL STRENGTH OF CATHODE RAY TUBES (CRT) AND PROTECTION N/A
AGAINST THE EFFECTS OF IMPLOSION
U.1 General N/A
Instructional safeguard : N/A
U.2 Test method and compliance for non-intrinsically protected CRTs N/A
U.3 Protective screen N/A
V DETERMINATION OF ACCESSIBLE PARTS P
V.1 Accessible parts of equipment P
V.1.1 General P
V.1.2 Surfaces and openings tested with jointed test Should be double evaluated in P
probes end product.
TRF No. IEC62368_1C
144 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 39 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
V.1.3 Openings tested with straight unjointed test probes Should be double evaluated in P
end product.
V.1.4 Plugs, jacks, connectors tested with blunt probe N/A
V.1.5 Slot openings tested with wedge probe N/A
V.1.6 Terminals tested with rigid test wire N/A
V.2 Accessible part criterion P
X ALTERNATIVE METHOD FOR DETERMINING CLEARANCES FOR INSULATION N/A
IN CIRCUITS CONNECTED TO AN AC MAINS NOT EXCEEDING 420 V PEAK
(300 V RMS)
Clearance ..................................................................: (See appended table X) N/A
Y CONSTRUCTION REQUIREMENTS FOR OUTDOOR ENCLOSURES N/A
Y.1 General N/A
Y.2 Resistance to UV radiation N/A
Y.3 Resistance to corrosion N/A
Y.3 Resistance to corrosion N/A
Y.3.1 Metallic parts of outdoor enclosures are resistant to N/A
effects of water-borne contaminants by ................ :
Y.3.2 Test apparatus N/A
Y.3.3 Water saturated sulphur dioxide atmosphere N/A
Y.3.4 Test procedure ....................................................... : N/A
Y.3.5 Compliance N/A
Y.4 Gaskets N/A
Y.4.1 General N/A
Y.4.2 Gasket tests N/A
Y.4.3 Tensile strength and elongation tests N/A
Alternative test methods ........................................ : N/A
Y.4.4 Compression test N/A
Y.4.5 Oil resistance N/A
Y.4.6 Securing means (See Annex P.4) N/A
Y.5 Protection of equipment within an outdoor enclosure N/A
Y.5.1 General N/A
Y.5.2 Protection from moisture N/A
Relevant tests of IEC 60529 or Y.5.3 .................... : N/A
Y.5.3 Water spray test N/A
Y.5.4 Protection from plants and vermin N/A
Y.5.5 Protection from excessive dust N/A
Y.5.5.1 General N/A
TRF No. IEC62368_1C
145 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 40 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Y.5.5.2 IP5X equipment N/A
Y.5.5.3 IP6X equipment N/A
Y.6 Mechanical strength of enclosures N/A
Y.6.1 General N/A
Y.6.2 Impact test ............................................................. : (See Table T.6) N/A
TRF No. IEC62368_1C
146 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 41 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.2 TABLE: Classification of electrical energy sources P
Supply Location (e.g. Test conditions Parameters ES Class
Voltage circuit
designation) U (V) I (mA) Type1) Additional
Info 2)
275Vac Primary circuits Normal -- -- -- --
supplied by a.c. ES3
Abnormal -- -- -- --
mains supply (declarati
Single fault -- -- -- -- on)
SC/OC
275Vac Primary circuit Normal 87.5mV 0.09mA SS 58.81kHz
ES1
and USB output
275Vac USB-A output Normal 5.06V 3.0A SS --
Abnormal 5.09V 3.38A SS --
output (OL)
Single fault 0 -- SS -- ES1
R8 (SC)
Single fault 0 -- SS --
R8 (OC)
198Vac USB-A output Normal 5.06V 3.0A SS --
Abnormal 5.08V 3.29A SS --
output (OL)
Single fault 0 -- SS -- ES1
R8 (SC)
Single fault 0 -- SS --
R8 (OC)
275Vac USB-C output Normal 5.04V 3.0A SS --
Abnormal 5.04V 3.37A SS --
output (OL)
Single fault 0 -- SS -- ES1
R8 (SC)
Single fault 0 -- SS --
R8 (OC)
198Vac USB-C output Normal 5.04V 3.0A SS --
Abnormal 5.04V 3.28A SS --
output (OL)
Single fault 0 -- SS -- ES1
R8 (SC)
Single fault 0 -- SS --
R8 (OC)
TRF No. IEC62368_1C
147 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 42 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
1) Type: Steady state (SS), Capacitance (CP), Single pulse (SP), Repetitive pulses (RP), etc.
2) Additional Info: Frequency, Pulse duration, Pulse off time, Capacitance value, etc.
5.4.1.8 TABLE: Working voltage measurement P
RMS voltage Peak voltage Frequency Comments
Location
(V) (V) (Hz)
Between L and N before fuse 250 353.5 50/60 Max. rms voltage
resistor
Between Input and output terminal 250 362 50/60 Max. rms and peak
voltage
Between transformer Pins 178 286 50/60 -
Between the pins of bridge 172 284 50/60 -
capacitor
Supplementary information:
5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics N/A
Method............................................................................................: ISO 306 / B50
Object/ Part No./Material Manufacturer/trademark Thickness (mm) T softening (°C)
Supplementary information:
5.4.1.10.3 TABLE: Ball pressure test of thermoplastics P
Allowed impression diameter (mm) ...............................................: 2 mm
Test Impression
Object/Part No./Material Manufacturer/trademark Thickness (mm)
temperature ( C) diameter (mm)
Bobbin of transformer CHANG CHUN 0.8 125 1.2
PLASTICS CO LTD
Insulation pad Silver age engineering 1.0 125 1.2
plastic
Supplementary information:
TRF No. IEC62368_1C
148 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 43 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.2, 5.4.3 TABLE: Minimum Clearances/Creepage distance P
Clearance (cl) and Up Urms Freq 1) Required cl E.S. 2) Required cr
creepage distance (V) (V) (Hz) cl (mm) (mm) (V) cr (mm) (mm)
(cr) at/of/between:
Line and neutral 354 250 <30 3.0 3.8 - 3.0 3.8
before fuse resistor
Differnet pole of fuse 354 250 <30 3.0 3.1 - 3.0 3.1
resistor
Primary and 362 250 58.81 3.0 6.2 - 3.0 6.2
secondary via CY1
Primary and 362 250 58.81 3.0 5.9 - 3.0 5.9
secondary via CY2
Input circuit and 362 250 58.81 5.5 6.6 - 5.5 6.6
output circuit via PCB
track
Primary and 362 250 58.81 5.5 7.5 - 5.5 7.5
secondary via T1
Core and secondary 362 250 58.81 5.5 7.5 - 5.5 7.5
of T1
Supplementary information:
1) Only for frequency above 30 kHz
2) Complete Electric Strength voltage (E.S. (V) when 5.4.2.4 applied)
5.4.4.2 TABLE: Minimum distance through insulation P
Distance through insulation Peak voltage (V) Insulation Required DTI Measured DTI
(DTI) at/of (mm) (mm)
PCB 362 RI 0.4 1.5
Insulation pad 362 RI 0.4 1.0
Bobbin 362 - - 0.8
Secondary winding of 362 RI 3 layers Certified TIW
transformer insulation wire
comply with
Annex J
Supplementary information:
5.4.4.9 TABLE: Solid insulation at frequencies >30 kHz N/A
Insulation material EP Frequency KR Thickness Insulation VPW
(kHz) d (mm) (Vpk)
TRF No. IEC62368_1C
149 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 44 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
5.4.9 TABLE: Electric strength tests P
Test voltage applied between: Voltage shape Test voltage (V) Breakdown
(Surge, Impulse, AC, Yes / No
DC, etc.)
Line and neutral before fuse resistor DC 4000 No
Differnet pole of fuse resistor DC 4000 No
Primary and secondary via CY1 DC 4000 No
Primary and secondary via CY2 DC 4000 No
Input circuit and output circuit via PCB track DC 6000 No
Primary and secondary via T1 DC 6000 No
Core and secondary of T1 DC 6000 No
Supplementary information:
5.5.2.2 TABLE: Stored discharge on capacitors N/A
Location Supply voltage (V) Operating and fault Switch Measured ES Class
condition 1) position voltage
(Vpk)
Supplementary information:
X-capacitors installed for testing:
bleeding resistor rating:
ICX:
1) Normal operating condition (e.g., normal operation, or open fuse), SC= short circuit, OC= open circuit
5.6.6 TABLE: Resistance of protective conductors and terminations N/A
Test current Duration Voltage drop Resistance
Location
(A) (min) (V) ( )
Supplementary information:
TRF No. IEC62368_1C
150 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 45 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.7.4 TABLE: Unearthed accessible parts N/A
Location Operating and Supply Parameters ES
fault conditions Voltage (V) class
Voltage Current Freq.
(Vrms or Vpk) (Arms or Apk) (Hz)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
5.7.5 TABLE: Earthed accessible conductive part N/A
Supply voltage (V) ........................... :
Phase(s) ......................................... : [] Single Phase; [ ] Three Phase: [ ] Delta [ ] Wye
Power Distribution System ............. : TN TT IT
Location Fault Condition No in IEC Touch current Comment
60990 clause 6.2.2 (mA)
Supplementary Information:
5.8 TABLE: Backfeed safeguard in battery backed up supplies N/A
Location Supply Operating and fault Time (s) Open-circuit Touch ES Class
voltage (V) condition voltage (V) current (A)
Supplementary information:
Abbreviation: SC= short circuit, OC= open circuit
6.2.2 TABLE: Power source circuit classifications P
Location Operating and fault Voltage (V) Current (A) Max. Time (S) PS class
condition Power1)
(W)
USB-A output Overload 5.09 3.38 17.20 5s PS2
USB-C output Overload 5.04 3.37 16.98 5s PS2
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
1) Measured after 3 s for PS1 and measured after 5 s for PS2 and PS3.
TRF No. IEC62368_1C
151 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 46 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.2.3.1 TABLE: Determination of Arcing PIS N/A
Location Open circuit voltage Measured r.m.s Calculated value Arcing PIS?
after 3 s (Vpk) current (A) Yes / No
Supplementary information:
6.2.3.2 TABLE: Determination of resistive PIS N/A
Location Operating and fault condition Dissipate power (W) Arcing PIS?
Yes / No
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit
8.5.5 TABLE: High pressure lamp N/A
Lamp manufacturer Lamp type Explosion method Longest axis of Particle found
glass particle beyond 1 m
(mm) Yes / No
Supplementary information:
9.6 TABLE: Temperature measurements for wireless power transmitters N/A
Supply voltage (V).......................................... :
Max. transmit power of transmitter (W).......... :
w/o receiver and with receiver and with receiver and at with receiver and at
direct contact direct contact distance of 2 mm distance of 5 mm
Object Ambient Object Ambient Object Ambient Object Ambient
Foreign objects (oC) (oC) (oC) (oC) (oC) (oC) (oC) (oC)
Supplementary information:
TRF No. IEC62368_1C
152 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 47 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Correction 2: 2022-09-07
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.4.1.4, TABLE: Temperature measurements P
9.3, B.1.5,
B.2.6
Supply voltage (V).......................................... : 198 275
Ambient temperature during test Tamb ( C) .... : 25 25
Maximum measured temperature T of part/at: T ( C) Allowed
Tmax ( C)
Internal Enclosure 47 48 For
reference
External Enclosure 39 40 77
Internal wire 60 59 65
Transformer winding 75 78 95*
Transformer core 67 69 For
reference
Y capacitor 62 70 110
PCB 62 63 115
Bulk-capacitor 62 61 For
reference
USB terminal 60 64 For
reference
Temperature T of winding: t1 (°C) R1 ( ) t2 (°C) R2 ( ) T ( C) Allowed Insulation
Tmax ( C) class
Supplementary information:
Tma=40 C is considered
B.2.5 TABLE: Input test P
U (V) Hz I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status
198 50 0.195 - 17.54 - RF1 0.195 Loaded with
5.0Vdc, 3.0A on
220 50 0.186 0.3 17.61 - RF1 0.186
one port.
250 50 0.173 0.3 17.72 - RF1 0.173 USB-A/USB-C
275 50 0.163 - 17.84 - RF1 0.163 port are same.
198 60 0.204 - 17.60 - RF1 0.204
220 60 0.189 0.3 17.64 - RF1 0.189
250 60 0.172 0.3 17.74 - RF1 0.172
275 60 0.161 - 17.83 - RF1 0.161
Supplementary information:
TRF No. IEC62368_1C
153 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 48 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.3, B.4 TABLE: Abnormal operating and fault condition tests P
Ambient temperature Tamb ( C)..................................................... : 25
Power source for EUT: Manufacturer, model/type, outputrating .. : Chroma, 61512, 18kVA
Component No. Condition Supply Test Fuse no. Fuse Observation
voltage time current
(V) (A)
Output overloaded to 5.08V,
Output Ol 198 2hrs FR1 0.23 3.20A. Transformer winding
temperature: 95ºC, no hazard.
Output overloaded to 5.09V,
3.22A. Transformer winding
Output Ol 275 2hrs FR1 0.19
temperature: 100ºC, no
hazard.
Circuit protected immediately;
Output Sc 198/275 5min FR1 0 no high temperature, no
hazard
Circuit protected immediately;
Transformer
Sc 198/275 5min FR1 0 no high temperature, no
(pin4-pin6)
hazard
Circuit protected immediately;
R8 Sc 198/275 5min FR1 0 no high temperature, no
hazard
Circuit protected immediately;
R8 Oc 198/275 5min FR1 0 no high temperature, no
hazard
Fuse resistor opened at
once. No permanent arcing;
C1 Sc 198/275 5min FR1 25->0 No ignition; No bursting of
the fuse resistor. Repeated
10 times.
Fuse resistor opened at
once. No permanent arcing;
BD1 (pin 1-pin2) Sc 198/275 5min FR1 25->0 No ignition; No bursting of
the fuse resistor. Repeated
10 times.
Supplementary information:
Meet the requirements of OSM decision OSM/EE 17.2A, maximum short circuit current is 25A.
M.3 TABLE: Protection circuits for batteries provided within the equipment N/A
Is it possible to install the battery in a reverse polarity position? ..... :
Charging
Equipment Specification Voltage (V) Current (A)
Battery specification
Non-rechargeable batteries Rechargeable batteries
Discharging Unintentional Charging Discharging Reverse
current (A) charging current (A) charging
Manufacturer/type Voltage (V) Current (A)
current (A) current (A)
TRF No. IEC62368_1C
154 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 49 of 86 Report No. 200302028SHA-001
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Note: The tests of M.3.2 are applicable only when above appropriate data is not available.
Specified battery temperature (oC) ................................................... :
Component Fault Charge/ Test Temp. Current Voltage Observation
No. condition discharge mode time (oC) (A) (V)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit NL= no chemical leakage; NS= no spillage of liquid; NE=
no explosion; NF= no emission of flame or expulsion of molten metal.
M.4.2 TABLE: Charging safeguards for equipment containing a secondary lithium N/A
battery
Maximum specified charging voltage (V) ..................................... :
Maximum specified charging current (A) ..................................... :
Highest specified charging temperature (oC) .............................. :
Lowest specified charging temperature (oC) ............................... :
Battery Operating Measurement Observation
manufacturer/type and fault
Charging Charging Temp.
condition
voltage (V) current (A) (oC)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified charging voltage; MSCC=
maximum specified charging current; HSCT= highest specified charging temperature; LSCT= lowest
specified charging temperature
Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) N/A
Output Isc (A) S (VA)
Condition Uoc (V) Time (s)
Circuit Meas. Limit Meas. Limit
Supplementary Information:
TRF No. IEC62368_1C
155 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 50 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
T.2, T.3, TABLE: Steady force test P
T.4, T.5
Force Test
Thickness
Part/Location Material Probe Duration Observation
(mm) (N) (s)
Components on - - - 10N 5 Cr/Cl not reduced
PCB below the
required values.
Cover plate COVESTRO / 1.5 - 250 5 Cr/Cl not reduced
FR6005+(z) below the
required values.
Supplementary information:
Building-in EUT should be evaluated in end product.
T.6, T.9 TABLE: Impact test P
Location/part Material Thickness Height Observation
(mm) (mm)
Cover plate COVESTRO / 1.5 1300 Remain effective as
FR6005+(z) safeguard against PS3 and
ES3
Supplementary information:
T.7 TABLE: Drop test N/A
Location/part Material Thickness Height Observation
(mm) (mm)
Supplementary information:
T.8 TABLE: Stress relief test P
Thickness Oven Temperature Duration
Location/Part Material Observation
(mm) ( C) (h)
Cover plate COVESTRO / 1.5 70 7 Remain effective as
FR6005+(z) safeguard against
PS3 and ES3
Base SHANGHAI 1.8 70 7 Remain effective as
SUNNY NEW safeguard against
TECHNOLOG PS3 and ES3
Y / HFP1010-
R
TRF No. IEC62368_1C
156 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 51 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
X TABLE: Alternative method for determining minimum clearances distances N/A
Clearance distanced Peak of working voltage Required cl Measured cl
between: (V) (mm) (mm)
Supplementary information:
TRF No. IEC62368_1C
157 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 52 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4.1.2 TABLE: Critical components information P
Object / part Manufacturer/ Type / model Technical data Standard Mark(s) of
No. trademark conformity1)
Covestro
PC, V-0; Min. Tested with
Cover plate Deutschland AG FR6005+(z) IEC/EN 62368-1
thickness: 1.5mm appliance
[PC Resins]
SHANGHAI SUNNY
PP, V-0; Min Tested with
Base NEW HFP1010-R IEC/EN 62368-1
thickness 1.8mm appliance
TECHNOLOGY
Silver age PP, Min. thickness Tested with
Insulation pad R716 IEC/EN 62368-1
engineering plastic 1.0mm appliance
PYS HIGH-TECH 22 AWG, 80 ºC, Tested with
Internal wire 1569 IEC/EN 62368-1
CO.,LTD. 300Vac, VW-1 appliance
KB-6150
KINGBOARD V-0, 130°C,
KB-6150C
LAMINATES Min thickness:
KB-6160A Tested with
PCB (MACAO 1.2 mm, IEC/EN 62368-1
KB-6060A appliance
COMMERCIAL Non-
KB-6160C
OFFSHORE) LTD thermoplastic
KB-6060
V-0, 130°C,
GUANGDONG
Min thickness:
HETONG Tested with
- alternative HT-M 1.2 mm, IEC/EN 62368-1
TECHNOLOGY CO appliance
Non-
LTD
thermoplastic
V-0, 130°C,
INTERNATIONAL ILM-R1## Min thickness:
Tested with
- alternative LAMINATE GF11/T600 1.2 mm, IEC/EN 62368-1
appliance
MATERIAL LTD ILM-U1## Non-
thermoplastic
V-0, 130°C,
SHENZHEN
Min thickness:
RUIBOXINYUAN Tested with
- alternative RBXY-3 1.2 mm, IEC/EN 62368-1
ELECTRONICS CO appliance
Non-
LTD
thermoplastic
Max. 2200pF,
Y capacitor Shenzhen Haotian IEC/EN 60384- VDE/
HT 400Vac,
(CY1, CY2) Electronic Co., Ltd. 14 40029300
25/125/21C, Y1
Max. 2200pF,
SOUTH CHINA
250Vac, IEC/EN 60384- VDE/
- alternative ELECTRONIC CO CY
25/125/21, C, Y1 14 40045823
LTD
type
DONGGUAN CITY Max. 2200pF,
DAFU 250Vac, IEC/EN 60384- VDE/
- alternative CT7
ELECTRONICS CO 25/125/21, C, Y1 14 40045823
LTD type
ANHUI
CHANGSHENG Tested with
Fuse resistor RXF21-1W 2.2Ohm, 1W IEC/EN 62368-1
ELECTRONICS CO appliance
LTD
SHENZHEN
GREAT Tested with
- alternative RXF-1W 2.2Ohm, 1W IEC/EN 62368-1
ELECTRONICS CO appliance
LTD
TRF No. IEC62368_1C
158 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 53 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
DONGGUAN
Transformer CROWN NEW
PYS- Tested with
(T1) includes ELECTRONIC Class 130(B) IEC/EN 62368-1
EI16018V appliance
a) to f) TECHNOLOGY CO
LTD
Dongguan Hualai
PYS- Tested with
- alternative Electronic Class 130(B) IEC/EN 62368-1
EI16018V appliance
Equipment Co Ltd
XIAMEN COST
PYS- Tested with
- alternative INDUSTRY AND Class 130(B) IEC/EN 62368-1
EI16018V appliance
TRADE CO LTD
SHENZHEN ZHIJIE
PYS- Tested with
- alternative ELECTRONICS CO Class 130(B) IEC/EN 62368-1
EI16018V appliance
LTD
PMC, V-0, 150ºC,
CHANG CHUN Tested with
a) Bobbin T375J thickness: 0.75 IEC/EN 62368-1
PLASTICS CO LTD appliance
mm
PF, V-0, 150ºC,
SUMITOMO Tested with
- alternative PM-9820 thickness: 0.75 IEC/EN 62368-1
BAKELITE CO LTD appliance
mm
JINGJIANG YAHUA
b) Insulating PRESSURE Tested with
PZ* (b) 130ºC IEC/EN 62368-1
tape SENSITIVE GLUE appliance
CO LTD
3M COMPANY
ELECTRICAL 1350F-1 (b), Tested with
- alternative 130ºC IEC/EN 62368-1
MARKETS DIV 1350F-2(C) appliance
(EMD)
c) Magnet JUNG SHING Tested with
UEY-2 @ 130ºC IEC/EN 62368-1
wire WIRE CO LTD appliance
FENG CHING Tested with
- alternative UEW-2 130ºC IEC/EN 62368-1
METAL CORP appliance
PACIFIC
ELECTRIC WIRE &
Tested with
- alternative CABLE UEW/U @ 130ºC IEC/EN 62368-1
appliance
(SHENZHEN) CO
LTD
TAI-I ELECTRIC
UEW Tested with
- alternative WIRE & CABLE 130ºC IEC/EN 62368-1
UEWB appliance
CO LTD
SHENZHEN
CHENGWEI (x)UEW-B- Tested with
- alternative 130ºC IEC/EN 62368-1
INDUSTRY CO (&)-(*) appliance
LTD
SUZHOU
d) Triple Reinforced
YUSHENG VDE
insulated TIW-B* insulation, 130°C, IEC/EN 62368-1
ELECTRONIC CO 40033527
wire 1410Vpeak
LTD
SHENZHEN
KAIZHONG Reinforced
VDE
- alternative HEDONG NEW TIW-B insulation, 130°C, IEC/EN 62368-1
40038861
MATERIAL CO 1000Vpeak
LTD
TRF No. IEC62368_1C
159 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 54 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
SHENZHEN
DARUN SCIENCE Reinforced
VDE
- alternative AND DRTIW-B insulation, 130°C, IEC/EN 62368-1
40032470
TECHNOLOGY CO 1000Vpeak
LTD
GREAT HOLDING
Min. 300V, 200ºC, Tested with
e) Tube INDUSTRIAL CO TFT, TFS IEC/EN 62368-1
VW-1 appliance
LTD
SHENZHENWOER-
HEAT-
200 °C, 600V, Tested with
- alternative SHRINKABLE WF IEC/EN 62368-1
VW-1 appliance
MATERIAL CO
LTD
JOHN C DOLPH Tested with
f) Varnish BC-346A 200ºC IEC/EN 62368-1
CO appliance
ELANTAS
ELECTRICAL
Tested with
- alternative INSULATION V1630FS 180ºC IEC/EN 62368-1
appliance
ELANTAS PDG
INC
HANG CHEUNG
Tested with
- alternative COATINGS 8562* 155ºC IEC/EN 62368-1
appliance
(HUIYANG) LTD
MAOMING
YINGDA FINE Tested with
- alternative MG209 130ºC IEC/EN 62368-1
CHEMICAL CO appliance
LTD
ELANTAS
ELECTRICAL
Tested with
- alternative INSULATION V1380FC 130ºC IEC/EN 62368-1
appliance
ELANTAS PDG
INC
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-2039.
2)Description line content is optional. Main line description needs to clearly detail the component used for
testing.
TRF No. IEC62368_1C
160 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 55 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Appendix No. 1: Photo of product
External view of end-product
Internal view of end-product
TRF No. IEC62368_1C
161 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 56 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Internal view of end-product
Internal view of end-product
TRF No. IEC62368_1C
162 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 57 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Insulation pad
PCB
TRF No. IEC62368_1C
163 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 58 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
PCB
Transformer
TRF No. IEC62368_1C
164 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 59 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Transformer
Transformer
TRF No. IEC62368_1C
165 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 60 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Transformer
Transformer
TRF No. IEC62368_1C
166 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 61 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Transformer
Transformer
TRF No. IEC62368_1C
167 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 62 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Transformer
Transformer
TRF No. IEC62368_1C
168 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 63 of 86 Report No. 200302028SHA-001
Correction 1: 2021-04-01
Transformer
Transformer
TRF No. IEC62368_1C
169 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 64 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ATTACHMENT TO TEST REPORT
IEC 62368-1
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
(AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY
REQUIREMENTS)
Differences according to ............... : EN IEC 62368-1:2020+A11:2020
Attachment Form No...................... : EU_GD_IEC62368_1C
Attachment Originator ................... : UL(Demko)
Master Attachment......................... : 2020-03-10
Copyright © 2020 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS (EN) P
Clause numbers in the cells that are shaded light grey are clause references in EN P
IEC 62368-1:2020+A11:2020. All other clause numbers in that column, except for
those in the paragraph below, refers to IEC 62368-1:2018.
Clauses, subclauses, notes, tables, figures and annexes which are additional to
those in IEC 62368-
Add the following annexes: P
Annex ZA (normative) Normative references to international publications
with their corresponding European publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Annex ZD (informative) IEC and CENELEC code designations for flexible
cords
1 Modification to Clause 3 . N/A
3.3.19 Sound exposure N/A
Replace 3.3.19 of IEC 62368-1 with the following definitions:
TRF No. IEC62368_1C
170 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 65 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
3.3.19.1 momentary exposure level, MEL N/A
metric for estimating 1 s sound exposure level from
the HD 483-1 S2 test signal applied to both
channels, based on EN 50332-1:2013, 4.2.
Note 1 to entry: MEL is measured as A-weighted levels in dB.
Note 2 to entry: See B.3 of EN 50332-3:2017 for additional
information.
3.3.19.3 sound exposure, E N/A
A-weighted sound pressure (p) squared and
integrated over a stated period of time, T
Note 1 to entry: The SI unit is Pa 2 s.
3.3.19.4 sound exposure level, SEL N/A
logarithmic measure of sound exposure relative to
a reference value, E0, typically the 1 kHz
threshold of hearing in humans.
Note 1 to entry: SEL is measured as A-weighted levels in dB.
dB
Note 2 to entry: See B.4 of EN 50332-3:2017 for additional
information.
3.3.19.5 digital signal level relative to full scale, dBFS N/A
levels reported in dBFS are always r.m.s. Full scale
level, 0 dBFS, is the level of a dc-free 997-
Hz sine wave whose undithered positive peak
value is positive digital full scale, leaving the code
corresponding to negative digital full scale unused
Note 1 to entry: It is invalid to use dBFS for non-r.m.s. levels.
Because the definition of full scale is based on a sine wave, the
level of signals with a crest factor lower than that of a sine wave
may exceed 0 dBFS. In particular, square wave signals may
reach +3,01 dBFS.
2 Modification to Clause 10 N/A
10.6 Safeguards against acoustic energy sources N/A
Replace 10.6 of IEC 62368-1 with the following:
10.6.1.1 Introduction N/A
Safeguard requirements for protection against
long-term exposure to excessive sound pressure
TRF No. IEC62368_1C
171 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 66 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
levels from personal music players closely coupled
to the ear are specified below. Requirements
for earphones and headphones intended for use
with personal music players are also covered.
A personal music player is a portable equipment
intended for use by an ordinary person, that:
is designed to allow the user to listen to audio or
audiovisual content / material; and
uses a listening device, such as headphones or
earphones that can be worn in or on or
around the ears; and
has a player that can be body worn (of a size
suitable to be carried in a clothing pocket) and
is intended for the user to walk around with while in
continuous use (for example, on a street,
in a subway, at an airport, etc.).
EXAMPLES Portable CD players, MP3 audio players, mobile
phones with MP3 type features, PDAs or similar equipment.
Personal music players shall comply with the
requirements of either 10.6.2 or 10.6.3.
NOTE 1 Protection against acoustic energy sources from
telecom applications is referenced to ITU-T P.360.
NOTE 2 It is the intention of the Committee to allow the
alternative methods for now, but to only use the dose
measurement method as given in 10.6.5 in future. Therefore,
manufacturers are encouraged to implement 10.6.5 as soon as
possible.
Listening devices sold separately shall comply with
the requirements of 10.6.6.
These requirements are valid for music or video
mode only.
The requirements do not apply to:
professional equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through
normal electronics stores are considered not to be professional
equipment.
hearing aid equipment and other devices for
assistive listening;
the following type of analogue personal music
players:
long distance radio receiver (for example, a
multiband radio receiver or world band radio
receiver, an AM radio receiver), and
cassette player/recorder;
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that
within a few years it will no longer exist. This exemption will not
be extended to other technologies.
a player while connected to an external amplifier
TRF No. IEC62368_1C
172 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 67 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
that does not allow the user to walk around
while in use.
For equipment that is clearly designed or intended
primarily for use by children, the limits of the
relevant toy standards may apply.
The relevant requirements are given in
EN 71-1:2011, 4.20 and the related tests methods
and measurement distances apply.
10.6.1.2 Non-ionizing radiation from radio frequencies N/A
in the range 0 to 300 GHz
The amount of non-ionizing radiation is regulated
by European Council Recommendation
1999/519/EC of 12 July 1999 on the limitation of
exposure of the general public to electromagnetic
fields (0 Hz to 300 GHz).
For intentional radiators, ICNIRP guidelines should
be taken into account for Limiting Exposure to
Time-Varying Electric, Magnetic, and
Electromagnetic Fields (up to 300 GHz). For hand-
held and body mounted devices, attention is drawn
to EN 50360 and EN 50566.
10.6.2 Classification of devices without the capacity to estimate sound dose N/A
10.6.2.1 General N/A
This standard is transitioning from short-term
based (30 s) requirements to long-term based (40
hour) requirements. These clauses remain in effect
only for devices that do not comply with sound
dose estimation as stipulated in EN 50332-3.
For classifying the acoustic output LAeq,T ,
measurements are based on the A-weighted
equivalent sound pressure level over a 30 s period.
For music where the average sound pressure (long
term LAeq,T) measured over the duration of the
song is lower than the average produced by the
programme simulation noise, measurements may
be done over the duration of the complete song. In
this case, T becomes the duration of the song.
NOTE Classical music, acoustic music and broadcast typically
has an average sound pressure (long term LAeq,T) which is
much lower than the average programme simulation noise.
Therefore, if the player is capable to analyse the content and
compare it with the programme simulation noise, the warning
does not need to be given as long as the average sound
pressure of the song does not exceed the required limit.
For example, if the player is set with the programme simulation
noise to 85 dB, but the average music level of the song is only
65 dB, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the
song is not above the basic limit of 85 dB.
TRF No. IEC62368_1C
173 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 68 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
10.6.2.2 RS1 limits (to be superseded, see 10.6.3.2) N/A
RS1 is a class 1 acoustic energy source that does
not exceed the following:
for equipment provided as a package (player with
its listening device), and with a proprietary
connector between the player and its listening
device, or where the combination of player and
listening device is known by other means such as
setting or automatic detection, the LAeq,T acoustic
output shall be 85 dB when playing the fixed
50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that
allows connection to a listening device for general
use, the unweighted r.m.s. output voltage shall be
27 mV (analogue interface) or -25 dBFS (digital
interface) when playing the
-1.
The RS1 limits will be updated for all devices as
per 10.6.3.2.
10.6.2.3 RS2 limits (to be superseded, see 10.6.3.3) N/A
RS2 is a class 2 acoustic energy source that does
not exceed the following:
for equipment provided as a package (player with
its listening device), and with a proprietary
connector between the player and its listening
device, or when the combination of player and
listening device is known by other means such as
setting or automatic 130 detection, the LAeq,T
acoustic output shall be 100 dB(A) when playing
described in EN 50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that
allows connection to a listening device for general
use, the unweighted r.m.s. output voltage shall be
150 mV (analogue interface) or -10 dBFS (digital
-1.
10.6.2.4 RS3 limits N/A
RS3 is a class 3 acoustic energy source that
exceeds RS2 limits.
10.6.3 Classification of devices (new) N/A
10.6.3.1 General N/A
Previous limits (10.6.2) created abundant false
negative and false positive PMP sound level
warnings. New limits, compliant with The
Commission Decision of 23 June 2009, are given
below.
TRF No. IEC62368_1C
174 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 69 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
10.6.3.2 RS1 limits (new) N/A
RS1 is a class 1 acoustic energy source that does
not exceed the following:
for equipment provided as a package (player
with its listening device), and with a proprietary
connector between the player and its listening
device, or where the combination of player and
listening device is known by other means such as
setting or automatic detection, the LAeq,T acoustic
output shall be 80 dB when playing the fixed
50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that
allows connection to a listening device for general
use, the unweighted r.m.s. output voltage shall be
15 mV (analogue interface) or -30 dBFS (digital
interface)
-1.
10.6.3.3 RS2 limits (new) N/A
RS2 is a class 2 acoustic energy source that does
not exceed the following:
for equipment provided as a package (player with
its listening device), and with a proprietary
connector between the player and its listening
device, or where the combination of player and
listening device is known by other means such as
setting or automatic detection, the weekly sound
exposure level, as described in EN 50332-3, shall
be 80 dB when playing the fixed "programme
simulation noise" described in EN 50332-1.
for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that
allows connection to a listening device for general
use, the unweighted r.m.s. output level, integrated
over one week, as described in EN50332-3, shall
be 15 mV (analogue interface) or -30 dBFS
(digital interface) when playing the fixed
50332-1.
10.6.4 Requirements for maximum sound exposure N/A
10.6.4.1 Measurement methods N/A
All volume controls shall be turned to maximum
during tests.
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
10.6.4.2 Protection of persons N/A
Except as given below, protection requirements for
parts accessible to ordinary persons, instructed
persons and skilled persons are given in 4.3.
TRF No. IEC62368_1C
175 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 70 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
NOTE 1 Volume control is not considered a safeguard.
Between RS2 and an ordinary person, the basic
safeguard may be replaced by an instructional
safeguard in accordance with Clause F.5, except
that the instructional safeguard shall be placed
on the equipment, or on the packaging, or in the
instruction manual.
Alternatively, the instructional safeguard may be
given through the equipment display during use.
The elements of the instructional safeguard shall
be as follows:
element 1a: the symbol , IEC 60417-6044
(2011-01)
wording
wording
An equipment safeguard shall prevent exposure
of an ordinary person to an RS2 source without
intentional physical action from the ordinary
person and shall automatically return to an output
level not exceeding what is specified for an RS1
source when the power is switched off.
The equipment shall provide a means to actively
inform the user of the increased sound level when
the equipment is operated with an output
exceeding RS1. Any means used shall be
acknowledged by the user before activating a
mode of operation which allows for an output
exceeding RS1. The acknowledgement does not
need to be repeated more than once every 20 h of
cumulative listening time.
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always needed.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent of how often and how long the personal
music player has been switched off.
A skilled person shall not be unintentionally
exposed to RS3.
10.6.5 Requirements for dose-based systems N/A
10.6.5.1 General requirements N/A
Personal music players shall give the warnings as
provided below when tested according to EN
50332-3, using the limits from this clause.
TRF No. IEC62368_1C
176 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 71 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
The manufacturer may offer optional settings to
allow the users to modify when and how they wish
to receive the notifications and warnings to
promote a better user experience without defeating
the safeguards. This allows the users to be
informed in a method that best meets their physical
capabilities and device usage needs. If such
optional settings are offered, an administrator (for
example, parental restrictions,
business/educational administrators, etc.) shall be
able to lock any optional settings into a specific
configuration.
The personal music player shall be supplied with
easy to understand explanation to the user of the
dose management system, the risks involved, and
how to use the system safely. The user shall be
made aware that other sources may significantly
contribute to their sound exposure, for example
work, transportation, concerts, clubs, cinema, car
races, etc.
10.6.5.2 Dose-based warning and requirements N/A
When a dose of 100 % CSD is reached, and at
least at every 100 % further increase of CSD, the
device shall warn the user and require an
acknowledgement. In case the user does not
acknowledge, the output level shall automatically
decrease to compliance with class RS1.
The warning shall at least clearly indicate that
listening above 100 % CSD leads to the risk of
hearing damage or loss.
10.6.5.3 Exposure-based requirements N/A
With only dose-based requirements, cause and
effect could be far separated in time, defying the
purpose of educating users about safe listening
practice. In addition to dose-based requirements,
a PMP shall therefore also put a limit to the short-
term sound level a user can listen at.
The exposure-based limiter (EL) shall automatically
reduce the sound level not to exceed 100 dB(A) or
150 mV integrated over the past 180 s, based on
methodology defined in EN 50332-3.
The EL settling time (time from starting level
reduction to reaching target output) shall be 10 s or
faster.
Test of EL functionality is conducted according to
EN 50332-3, using the limits from this clause. For
equipment provided as a package (player with its
listening device), the level integrated over 180 s
shall be 100 dB or lower. For equipment provided
TRF No. IEC62368_1C
177 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 72 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
with a standardized connector, the unweighted
level integrated over 180 s shall be no more than
150 mV for an analogue interface and no more
than -10 dBFS for a digital interface.
NOTE In case the source is known not to be music (or test
signal), the EL may be disabled.
TRF No. IEC62368_1C
178 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 73 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
10.6.6 Requirements for listening devices (headphones, earphones, etc.) N/A
10.6.6.1 Corded listening devices with analogue input N/A
With 94 dB LAeq acoustic pressure output of the
listening device, and with the volume and sound
settings in the listening device (for example, built-in
volume level control, additional sound features like
equalization, etc.) set to the combination of
positions that maximize the measured acoustic
output, the input voltage of the listening device
-1 shall be 75
mV.
NOTE The values of 94 dB and 75 mV correspond with 85 dB
and 27 mV or 100 dB and 150 mV.
10.6.6.2 Corded listening devices with digital input N/A
With any playing device playing the fixed
50332-1, and with the volume and sound settings in
the listening device (for example, built-in volume
level control, additional sound features like
equalization, etc.) set to the combination of
positions that maximize the measured acoustic
output, the LAeq,T acoustic output of the listening
device shall be 100 dB with an input signal of -10
dBFS.
10.6.6.3 Cordless listening devices N/A
In cordless mode,
with any playing and transmitting device playing
the fixed programme simulation noise described in
EN 50332-1; and
respecting the cordless transmission standards,
where an air interface standard exists that specifies
the equivalent acoustic level; and
with volume and sound settings in the receiving
device (for example, built-in volume level control,
additional sound features like equalization, etc.) set
to the combination of positions that maximize the
measured acoustic output for the above mentioned
programme simulation noise, the LAeq,T acoustic
output of the listening device shall be 100 dB with
an input signal of -10 dBFS.
10.6.6.4 Measurement method N/A
Measurements shall be made in accordance with
EN 50332-2 as applicable.
3 Modification to the whole document P
TRF No. IEC62368_1C
179 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 74 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Delete P
list:
4 Modification to Clause 1 N/A
1 Add the following note: N/A
NOTE Z1 The use of certain substances in electrical and
electronic equipment is restricted within the EU: see Directive
2011/65/EU.
TRF No. IEC62368_1C
180 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 75 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
5 Modification to 4.Z1 N/A
4.Z1 Add the following new subclause after 4.9: N/A
To protect against excessive current, short-circuits
and earth faults in circuits connected to an a.c.
mains, protective devices shall be included either
as integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of B.3.1 and B.4 shall be included as parts of the
equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by
protective devices in the building installation;
c) it is permitted for pluggable equipment type B
or permanently connected equipment, to rely on
dedicated overcurrent and short-circuit protection
in the building installation, provided that the means
of protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for pluggable equipment type
A the building installation shall be regarded as
providing protection in accordance with the rating
of the wall socket outlet.
6 Modification to 5.4.2.3.2.4 N/A
5.4.2.3.2.4 Add the following to the end of this subclause: N/A
The requirement for interconnection with external
circuit is in addition given in EN 50491-3:2009.
7 Modification to 10.2.1 N/A
10.2.1 Add the following to c) and d) in table 39: N/A
For additional requirements, see 10.5.1.
TRF No. IEC62368_1C
181 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 76 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
8 Modification to 10.5.1 N/A
10.5.1 Add the following after the first paragraph: N/A
For RS 1 compliance is checked by measurement
under the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside by hand, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Z1 Soldered joints and paint lockings are examples of
adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
For RS1, the dose-
taking account of the background level.
NOTE Z2 These values appear in Directive 96/29/Euratom of 13
May 1996.
9 Modification to G.7.1 N/A
G.7.1 Add the following note: N/A
NOTE Z1 The harmonized code designations corresponding to
the IEC cord types are given in Annex ZD.
TRF No. IEC62368_1C
182 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 77 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
10 Modification to Bibliography P
Add the following notes for the standards indicated: P
11 ADDITION OF ANNEXES N/A
ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN ) N/A
4.1.15 Denmark, Finland, Norway and Sweden N/A
To the end of the subclause the following is
added:
Class I pluggable equipment type A intended
for connection to other equipment or a
network shall, if safety relies on connection to
reliable earthing or if surge suppressors
are connected between the network terminals
and accessible parts, have a marking stating
that the equipment shall be connected to an
earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Denmark
en stikkontakt med jord som giver forbindelse til
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway
In Sweden
TRF No. IEC62368_1C
183 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 78 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
4.7.3 United Kingdom N/A
To the end of the subclause the following is added:
The torque test is performed using a socket-outlet
complying with BS 1363, and the plug part shall be
assessed to the relevant clauses of BS 1363. Also
see Annex G.4.2 of this annex
5.2.2.2 Denmark N/A
After the 2nd paragraph add the following:
A warning (marking safeguard) for high touch
current is required if the touch current exceeds the
limits of 3,5 mA a.c. or 10 mA d.c.
5.4.11.1 Finland and Sweden N/A
and
Annex G To the end of the subclause the following is added:
For separation of the telecommunication network
from earth the following is applicable:
If this insulation is solid, including insulation forming
part of a component, it shall at least
consist of either
two layers of thin sheet material, each of which
shall pass the electric strength test below, or
one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that clearances and
creepage distances do not exist, if the component
passes the electric strength test in accordance with
the compliance clause below and in addition
passes the tests and inspection criteria of 5.4.8
with an electric strength test of 1,5 kV multiplied
by 1,6 (the electric strength test of 5.4.9 shall be
performed using 1,5 kV),
and
is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5
kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
TRF No. IEC62368_1C
184 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 79 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
A capacitor classified Y3 according to EN 60384-
14:2005, may bridge this insulation under
the following conditions:
the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 60384-14, which in addition to the Y3
testing, is tested with an impulse test of 2,5 kV
defined in 5.4.11;
the test specimens as described in EN 60384-
14;
the impulse test of 2,5 kV is to be performed before
the endurance test in EN 60384-14, in the
sequence of tests as described in EN 60384-14.
5.5.2.1 Norway N/A
After the 3rd paragraph the following is added:
Due to the IT power system used, capacitors are
required to be rated for the applicable line-to-line
voltage (230 V).
5.5.6 Finland, Norway and Sweden N/A
To the end of the subclause the following is added:
Resistors used as basic safeguard or bridging
basic insulation in class I pluggable equipment
type A shall comply with G.10.1 and the test of
G.10.2.
5.6.1 Denmark N/A
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with fuses
with higher rating than the rating of the socket-
outlets the protection for pluggable
equipment type A shall be an integral part of the
equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
5.6.4.2.1 Ireland and United Kingdom N/A
After the indent for pluggable equipment type A,
the following is added:
the protective current rating is taken to be 13 A,
this being the largest rating of fuse used in the
mains plug.
TRF No. IEC62368_1C
185 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 80 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
5.6.4.2.1 France N/A
After the indent for pluggable equipment type A,
the following is added:
in certain cases, the protective current rating of
the circuit supplied from the mains is taken as 20 A
instead of 16 A.
5.6.5.1 To the second paragraph the following is added: N/A
The range of conductor sizes of flexible cords to be
accepted by terminals for equipment with a rated
current over 10 A and up to and including 13 A is:
1,25 mm2 to 1,5 mm2 in cross-sectional area.
5.6.8 Norway N/A
To the end of the subclause the following is added:
Equipment connected with an earthed mains plug is
classified as class I equipment. See the Norway
marking requirement in 4.1.15. The symbol IEC
60417-6092, as specified in F.3.6.2, is accepted.
5.7.6 Denmark N/A
To the end of the subclause the following is added:
The installation instruction shall be affixed to the
equipment if the protective conductor current
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.
TRF No. IEC62368_1C
186 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 81 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
5.7.6.2 Denmark N/A
To the end of the subclause the following is added:
The warning (marking safeguard) for high touch
current is required if the touch current or the
protective current exceed the limits of 3,5 mA .
5.7.7.1 Norway and Sweden N/A
To the end of the subclause the following is added:
The screen of the television distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building.
Therefore the protective earthing of the building
installation needs to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by a retailer, for example.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
the building installation through the mains
connection or through other apparatus with a
connection to protective earthing
and to a television distribution system using coaxial
cable, may in some circumstances create a fire
hazard. Connection to a television distribution
system therefore has to be provided through a
device providing electrical isolation below a certain
frequency range (galvanic isolator, see EN 60728-
NOTE In Norway, due to regulation for CATV-installations, and
in Sweden, a galvanic isolator shall provide electrical insulation
below 5 MHz. The insulation shall withstand a dielectric strength
of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
om er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr og er tilkoplet et koaksialbasert kabel-TV
nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av
apparater til kabel-TV nett installeres en
galvanisk isolator mellom apparatet og kabel-TV
TRF No. IEC62368_1C
187 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 82 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
Translation to Swedish:
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
vid anslutning av apparaten till kabel-TV nät
galvanisk isolator finnas mellan apparaten och
kabel-
8.5.4.2.3 United Kingdom N/A
Add the following after the 2nd dash bullet in 3rd
paragraph:
An emergency stop system complying with the
requirements of IEC 60204-1 and ISO 13850 is
required where there is a risk of personal injury.
B.3.1 and Ireland and United Kingdom N/A
B.4
The following is applicable:
To protect against excessive currents and short-
circuits in the primary circuit of direct plug-in
equipment, tests according to Annexes B.3.1 and
B.4 shall be conducted using an external miniature
circuit breaker complying with EN 60898-1, Type B,
rated 32A. If the equipment does not pass these
tests, suitable protective devices shall be included
as an integral part of the direct plug-in
equipment, until the requirements of Annexes
B.3.1 and B.4 are met
TRF No. IEC62368_1C
188 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 83 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
G.4.2 Denmark N/A
To the end of the subclause the following is added:
Supply cords of single phase appliances having a
rated current not exceeding 13 A shall be provided
with a plug according to DS 60884-2-D1:2011.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a polyphase
equipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6-1a in DS 60884-2-D1 or EN
60309-2.
Mains socket outlets intended for providing power
to Class II apparatus with a rated current of 2,5 A
shall be in accordance DS 60884-2-D1:2011
standard sheet DKA 1-4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet DKA 1-3a
or DKA 1-1c.
Mains socket-outlets with earth shall be in
compliance with DS 60884-2-D1:2011
Standard Sheet DK 1-3a, DK 1-1c, DK1-1d, DK 1-
5a or DK 1-7a
Justification:
Heavy Current Regulations, Section 6c
G.4.2 United Kingdom N/A
To the end of the subclause the following is added:
The plug part of direct plug-in equipment shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16, and 12.17, except
that the test of 12.17 is performed at not less than
125 °C. Where the metal earth pin is replaced by
an Insulated Shutter Opening Device (ISOD), the
requirements of clauses 22.2 and 23 also apply.
TRF No. IEC62368_1C
189 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 84 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
G.7.1 United Kingdom N/A
To the first paragraph the following is added:
Equipment which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
(Safety) Regulations 1994, Statutory Instrument
1994 No. 1768, unless exempted by those
regulations.
NOTE "Standard plug" is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS 1363 or
an approved conversion plug.
G.7.1 Ireland N/A
To the first paragraph the following is added:
Apparatus which is fitted with a flexible cable or
cord shall be provided with a plug in accordance
and Conversion Adapters for Domestic Use
Regulations: 1997. S.I. 525 provides for the
recognition of a standard of another Member State
which is equivalent to the relevant Irish Standard
G.7.2 Ireland and United Kingdom N/A
To the first paragraph the following is added:
A power supply cord with a conductor of 1,25 mm2
is allowed for equipment which is rated over 10 A
and up to and including 13 A.
TRF No. IEC62368_1C
190 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 85 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A
10.5.2 Germany N/A
The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV,
authorization is required, or application of type
approval (Bauartzulassung) and marking.
Justification:
German ministerial decree against ionizing
radiation (Röntgenverordnung), in force since
2002-07-01, implementing the European Directive
96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-
38116 Braunschweig,
Tel.: Int+49-531-592-6320, Internet: http://www.ptb.de
TRF No. IEC62368_1C
191 TEST REPORTS FOR 5 721 42 WHICH IS THE SAME OFFERED MATERIAL 5 721 39
Page 86 of 86 Report No. 200302028SHA-001
IEC62368_1C- ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
ZD IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS (EN) N/A
N/A
TRF No. IEC62368_1C
Arteor TM
international socket outlets
5 721 23 5 721 35 5 721 10 5 710 41 5 724 63 5 721 04 5 726 33 5 700 47
Support frame and plate selection charts p. 594-603
Mechanisms supplied with rocker plates, to be equipped with support frames (p. 585) and plates (p. 594-603)
Pack Cat.Nos Multistandard socket outlets Pack Cat.Nos German standard socket outlets 16 A
2P+E unswitched - shuttered for child safety - 2 modules
2 modules 2P+E shuttered for child safety
10 5 721 23 White 10 5 721 18 White
10 5 726 23 Magnesium 10
10
5 726 18 Magnesium
5 700 42 Champagne 10
10 5 710 42 Soft Alu 5 700 41 Champagne
10 5 710 41 Soft Alu
2P+E switched - shuttered for child safety - 10 5 724 62 Dedicated green
3 modules 10
5 5 721 35 5 724 60 Dedicated orange
White
5 5 726 35 Magnesium 2P+E tamperproof, shuttered for child safety
5 5 724 42 Champagne Used to identify a mains circuit (e.g. inverter) and
5 5 724 41 Soft Alu avoid connection of unnecessary equipment which
may cause interference on the circuit
British standard socket outlets To be used with tamperproof insert Cat.No 0 502 99
Shuttered for child safety (see p. 577)
ASTA licence 10 5 724 63 Red tamperproof
Conform to BS 1363 Part 2
2P+E switched - 15 A
Conform to BS 546 2P+E with cover
3 modules 10 5 721 19 White
5 5 721 32 White Socket outlet for floor 10 5 726 19 Magnesium
5 5 726 32 Magnesium mounted boxes. RED 10 5 710 19 Champagne
5 5 700 45 Champagne cover will be produced for 10 5 700 19 Soft Alu
5 5 710 45 Soft Alu BCOM project.
2P+E - 13 A Euro-US type socket outlets - 15 A - 127 V /
Conform to BS 1363 Part 2 16 A - 250 V
ASTA licence 2P with shutters - 1 module
2 modules 10 5 721 04 White
10 5 721 11 White 10 5 726 04 Magnesium
10 5 726 11 Magnesium 10 5 700 37 Champagne
10 5 700 38 Champagne 10 5 710 37 Soft Alu
10 5 710 38 Soft Alu
10
2P+E with shutters - 2 modules
5 726 41 Red 10 5 721 16 White
2P+E switched - 13 A 10 5 726 16 Magnesium
Conform to BS 1363 Part 2 10 5 700 39 Champagne
ASTA licence 10 5 710 39 Soft Alu
3 modules 2 x 2P+E with shutters - 3 modules
5 5 721 30 White 5 5 721 33 White
5 5 726 30 Magnesium 5 5 726 33 Magnesium
5 5 700 44 Champagne 5 5 700 46 Champagne
5 5 710 44 Soft Alu 5 5 710 46 Soft Alu
5 5 724 67 Red dedicated non standard pin
2P+E - 5 A American type socket outlets 15 A - 127 V
Conform to BS 546 2P - 1 module
2 modules 10 5 721 05 White
10 5 721 10 White 10 5 726 05 Magnesium
10 5 726 10 Magnesium 10 5 710 72 Champagne
10 5 710 71 Champagne 10 5 700 72 Soft Alu
10 5 700 71 Soft Alu 2P+E - 2 modules
10 5 721 17 White
10 5 726 17 Magnesium
10 5 700 40 Champagne
10 5 710 40 Soft Alu
2 x 2P+E - 3 modules
5 5 721 34 White
5 5 726 34 Magnesium
5 5 700 47 Champagne
5 5 710 47 Soft Alu
Red catalogue numbers: New products
574
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France
Tel: 0 (+33) 5 55 06 87 87 Fax: 0 (+33) 5 55 06 88 88
www.legrand.com
ArteorTM Cat. No(s): 5 700 44 - 5 710 44 - 5 721 30 - 5 726 30 - 5 724 67
British standard socket outlets
1. USE 5. TECHNICAL CHARACTERISTICS
2 P+E british sandard socket outlets shuttered for child safety. 5.1 Mechanical characteristics
Mechanisms supplied with rocker plates, to be equipped with support Protection against impact: IK 04
frames and plates. Protection against solid bodies and liquids: IP 40 (mounted)
Flush mounting or surface mounting. IP 20 (alone)
5.2 Material characteristics
2. RANGE Polyglass appearance
Base: Polycarbonate
Cover plates: Polycarbonate
White Magnesium Red Soft Alu Champagne Halogen free
2 P+E socket UV resistant
outlets swit- Self-extinguishing:
ched 5 721 30 5 726 30 - 5 710 44 5 700 44 + 850° C / s for insulating parts holding live parts in place
With shutters + 650° C / 30 s for other parts made of insulating materials.
3 modules 5.3 Electrical characteristics
2 P+E socket Voltage: 250 V~
outlet swit- Current: 13 A
ched dedicated Frequency: 50/60 Hz
non standard - - 5 724 67 - - 5.4 Climatic characteristics
pin. Storage temperature: - 10° C to + 70° C
With shutters Use temperature: - 5° C to + 35° C
3 modules
Résistance à l'arrachement : 200-226 N
6. MAINTENANCE
3. DIMENSIONS (mm)
Surface cleaning with a cloth.
B C Do not use: acetone, tar remover, trichloroethylene.
D
Maintenance with the following products: Hexane (EN 60669-1),
Methylated spirit, Soapy water, Diluted ammonia, Bleach diluted to 10%,
Window-cleaning products.
A
Caution: A
lways test before using other special cleaning products
7. STANDARDS AND APPROVALS
A B C D Compliance with standards of installation and manufacturing.
45 67.5 34 13 Refer to e. catalogue.
4. CONNECTION
Number of terminals: 3 terminals
Type of terminals: with screws
Terminal capacity: 3 x 4 mm2
Striping length: 9 mm
Screwdriver: cross-head max. 4 mm flat-blade
Technical data sheet: F02592EN/01 Updated: 09/02/2021 Created: 16/02/2018
1/1
Ref. Certif. No.
FR_706411/M1
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT
(IECEE) CB SCHEME
CB TEST CERTIFICATE
Product Fixed switched socket-outlet
Switched socket-outlets for fixed installations
Name and address of the applicant LEGRAND MAGYARORSZAG VILLAMOSSAGI RENDSZEREK
ZRt
IPARTELEPI UT 14 PF 10
6600 SZENTES- HUNGARY
Name and address of the manufacturer LEGRAND FRANCE
128 AVENUE DU MARECHAL DE LATTRE DE TASSIGNY
87045 LIMOGES CEDEX- FRANCE
Name and address of the factory LEGRAND MAGYARORSZAG VILLAMOSSAGI RENDSZEREK
ZRt
IPARTELEPI UT 14 PF 10
6600 SZENTES - HUNGARY
Note: When more than one factory, please report on page 2 Additional Information on page 2
Ratings and principal characteristics See Annex
Trademark / Brand (if any)
Customer’s Testing Facility (CTF) Stage used /
Model / Type Ref. See Annex
Additional information (if necessary may also be Supersedes CBTC FR_706411 dated 22/07/2019. Change the
reported on page 2) name and address of manufacturer
Additional Information on page 2
A sample of the product was tested and found to IEC 60884-2-3:2006
be in conformity with IEC 60884-1:2002(ed.3) +A1:2006 +A2:2013
As shown in the Test Report Ref. No. which ARFH-ESH-P22101318
forms part of this Certificate ARFH-19MY0492ACSHP
This CB Test Certificate is issued by the National Certification Body
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 15/12/2022 Signature: Julien GAUTHIER
Certification Officer
1/2
Ref. Certif. No.
FR_706411/M1
ANNEX
References, ratings and main characteristics:
Color of with cover with support
Reference Range* Description
enclosure plate frame
2P+E 13A British Standard Single
572130 ARTEOR White 575070 576002
Pole switched 1 gang
Magnesium
2P+E 13A British Standard Single cover with
572630 ARTEOR 575072 576002
Pole switched 1 gang black cover
plate
Champagne
2P+E 13A British Standard Single cover with
570044 ARTEOR 575072 576002
Pole switched 1 gang black cover
plate
Alu cover with
2P+E 13A British Standard Single
571044 ARTEOR black cover 575072 576002
Pole switched 1 gang
plate
* The “range” denotes applicant’s categorization.
standard Sheet: standard sheet of BS 1363-2
rated current (A) 13A
rated voltage (V) 250V
degree of protection IP20
provision for earthing with earthing contact
method of connecting the cable rewirable
type of terminals screw-type
colour White, Magnesium, Champagne, Alu, Red, Green, Orange
socket-outlets
multiple socket-outlets
13A : 1
number of socket-outlets
degree of protection against electric shock normal protection
existence of shutters with shutters
method of application - mounting flush-type
method of installation design A
Intended for circuits where a single earthing circuit provides protective earthing
Switched socket-outlets without
interlock
According to the method of actuating the rocker
switch
According to the switching of the neutral unswitched neutral
LABORATOIRE CENTRAL DES INDUSTRIES ELECTRIQUES - LCIE
33 avenue du Général Leclerc
92260 Fontenay-aux-Roses, FRANCE
www.lcie.fr
Date: 15/12/2022 Signature: Julien GAUTHIER
Certification Officer
2/2