SICAR Automation Software
What’s new in V5.0?
January 2024
Unrestricted | © Siemens 2024
What new features does SICAR
Automation Software V5.0 have?
Unrestricted | © Siemens 2024
New look & feel
W hat ’s c om i ng i n S IC A R V 5.0? Our SICAR will come in a completely new style based on
HMI Template Suite for Unified – however sticking to the
best practices from previous SICAR versions.
New visualization style
aligned with HMI
Template Suite for
WinCC Unified
Clean visualization
Consistent style
Page 3 Unrestricted | © Siemens 2024
User Guidance
W hat ’s c om i ng i n S IC A R V 5.0? Clear user guidance with defined levels of navigation.
- 1st level navigation on the right side of the screen
- 2nd level navigation on the bottom of the screen
New user guidance in - 3rd level navigation on the left side
visualization
Page 4 Unrestricted | © Siemens 2024
Integration of Software Units
W hat ’s c om i ng i n S IC A R V 5.0? SICAR Automation Software V5.0 will integrate Software
Units making commissioning with multiple engineers at
one machine easier than ever.
Software Units for a
more modular software
architecture and multi-
user commissioning
Structure of Software Units in Detailed view – each with own OB1 if
SICAR needed
Page 5 Unrestricted | © Siemens 2024
Software Units and their relations
To exchange information Software Units need to have defined communication channels
– the so-called relations.
- Library: providing library functions to other
Software Units e.g. TecUnits
GlobalData SW Unit
- OpModeAreaX: Encapsulates all the
functionalities of one operating mode area like
OpMode OpMode OpMode Central
OpMode-FB, process logic
Safety
Area1 Area2 AreaN Functions
- GlobalData: Serves as central data household
instanciates and interface between other Software Units or
to periphery
Library SW-Unit
- CentralFunctions: functions needed by multiple
Operating Mode Areas
- Safety: containing safety programming
Page 6 Unrestricted | © Siemens 2024
Operating mode area & Panel blocks
W hat ’s c om i ng i n S IC A R V 5.0? In V5.0, SICAR Automation Software will be simpler to
parametrize with no hard limit in the number of panels per
operating mode area.
Individualization and
flexibilization of
Operating mode area
& Panel blocks
Page 7 Unrestricted | © Siemens 2024
Configuring Panel rights directly in the data block
The definition of an HMI’s control rights happens directly in the OpmodePanel Datablock
One 2-dimensional array defining the control rights of each panel
Page 8 Unrestricted | © Siemens 2024
HMI-Exclusive control: Interlocking distinct OpModeAreas
To ensure exclusive control for one Operating Mode area HMIs can interlock an Operating Mode.
Interlocking of Operating Mode Areas
- either one Operating Mode Area or
- all
Overview of interlocked Operating
Mode Areas:
- Operating Mode Areas and interlocking
HMIs can be seen from all HMIs
- Interlocking HMI must release Operating
Mode Areas before another HMI can
interlock it again.
Page 9 Unrestricted | © Siemens 2024
User authentication
W hat ’s c om i ng i n S IC A R V 5.0? User authentication is important for every machine. With
SICAR Automation Software V5.0 we will have the local
user authentication integrated.
User management and
roles
Page 10 Unrestricted | © Siemens 2024
Multi-Movement
W hat ’s c om i ng i n S IC A R V 5.0? Selecting the movements that should be executed.
Executing all at the same time.
Improvement of manual Option 1: Selecting in the faceplates directly
control with parallel
movement of multiple
TecUnits
Option 2: Selecting at manual movement lines
Page 11 Unrestricted | © Siemens 2024
Manual movement
W hat ’s c om i ng i n S IC A R V 5.0? Controlling the machine in manual mode
Additional possibility for Option 1: Controlling directly in the faceplate
manual control
directly in the
faceplate Option 2: Controlling in the OpMode Screen as popup
Option 3: Controlling in the manual operations screen
Page 12 Unrestricted | © Siemens 2024
W hat ’s c om i ng i n S IC A R V 5.0?
Alarming: Messages
using global alarm text
list IDs
Page 13 Unrestricted | © Siemens 2024
W hat ’s c om i ng i n S IC A R V 5.0?
SICAR Library TecUnits
with and without
ProDiag in one Block
Page 14 Unrestricted | © Siemens 2024
Selecting / deselecting of
W hat ’s c om i ng i n S IC A R V 5.0? rules the project should
be checked for
SICAR using Test Suite
Advanced
Using SICAR’s predefined rule set
based on TIA Programming Styleguide
projects can be automatically checked
against your ruleset for formal
conformity regarding
- Addressing of parameters,
- parameter names,
- comments,
- languages,
- and many more …
Automatically checking the project for
conformity
Page 15 Unrestricted | © Siemens 2024
W hat ’s c om i ng i n S IC A R V 5.0?
Automating screen
generation with SIVARC
Rule Integration SIVARC rules for SICAR base project
SICAR screen generation
Page 16 Unrestricted | © Siemens 2024
W hy W i nC C U ni fi ed?
Standalone Instances
PCs or Unified Comfort Panel running
Additional requirements an independent WinCC Unified
instance. WinCC Unified Unified PC
when using Server-
Client architectures
Unified Comfort Panel
Server Client Architectures
One server providing the Visualization for
different clients that can be
Client
- other PCs or
- mobile clients
Client
Unified Server
Client
Page 17 Unrestricted | © Siemens 2024
Connection supervision
… making sure that only those
devices can connect which are
allowed to
… supervising the connection of
each client. Detecting any
interruption of the connection
… making sure not more than the
allowed number of clients connects
to the server
Page 18 Unrestricted | © Siemens 2024
W hat ’s c om i ng i n S IC A R V 5.0?
Server-Client architectures require
specific measures to ensure exclusive
control:
Client-Exclusive
controllability making
sure there’s always only
one client controlling in
manual mode
Page 19 Unrestricted | © Siemens 2024
W hat ’s c om i ng i n S IC A R V 5.0?
Update software documentation using
Code2Docu.
Storing the software description in the
block code for easy generation of the
user documentation.
Page 20 Unrestricted | © Siemens 2024
Thank you for your attention!
Daniel Gauglitz
System Manager SICAR
DI FA SO FPS
E-Mail: [email protected]
Page 21 Unrestricted | © Siemens 2024