SP 1800 SP 1800 SP 1800 SP 1800
Pump unit mm 200/120 200/120 200/120 200/120
Technical parameter 1875 2250 1850 3150
Portable
Engine/motor capacity kW E 75 E 90 D 74 D 126 concrete pump
Nominal speed 1/min 1500 1500 2300 2300
Pumping cylinder, stroke mm 200 x 1600 200 x 1600 200 x 1600 200 x 1600
Stroke volume, 2 cylinders l 50,27 50,27 50,27 50,27
Diff. cylinders, stroke mm 120 / 80 x 1600 120 / 80 x 1600 120 / 80 x 1600 120 / 80 x 1600 SP 1800
Diff. cylinder drive* P R P R P R P R
Max. number of strokes per min. 14 24 14 24 14 24 14 24
Max. theor. concrete output m3/h 42 73 42 73 42 73 42 73
Max. concrete pressure bar 108 60 108 60 108 60 108 60
Capacity of charging hopper l 320/570 320/570 320/570 320/570
Dead weight incl. oil and fuel kg 4000 4000 4000 4000
Delivery line up to mm 150 150 150 150
* P = piston side, R = rod side
Dimensions in mm
3073
1674
1400
2019
1536
840
10187269 (1000.04.07) S
1318 3000
1937 5725
SCHWING GmbH Subject to modifications in the
P.O. Box 20 03 62 interest of technical progress.
Details of the standard extent of supply
D-44647 Herne /Germany are to be drawn from the offer.
Heerstr. 9-27 · D-44653 Herne
ꇴ (0) 23 25 / 9 87-0
Fax (0) 23 25 / 729 22
E-Mail:
[email protected] Internet: www.schwing.de
SP 1800 – compact and robust
for all-round service.
The 75 – 126 kW class is a de- New in the class is our machines. As on all SCHWING set the pump to a required fine output losses and minimum that runs on continually and Rock valve
cisive grouping among the trail- SP 1800 – a pump with a concrete pumps, the SP 1800 tuning to set stroke rate and stress for the hydraulic compo- turns valuable energy into The heart of the concrete pump
er concrete pumps. whole row of qualities and new has an output-governed hy- output independent of the au- nents. wasteful heat. is the Rock valve, patented in
It is a class that hardly ever features. draulic pump that ensures that tomatic governor. During short breaks in pump- As a second function, the main almost all industrialized coun-
sees any spectacular applica- With a cylinder stroke of 1,600 the prime mover is never over- Open-circuit hydraulics have ing, the main control spool is spool also isolates the drive tries. It offers exemplary pump-
tions or record jobs. But it is mm, the SP 1800 reaches its loaded. The automatic gover- been a major feature of all shifted to “idle circuit” so that circuits from the concrete ing characteristics, wearing
the class in which the greatest full output of 73 m3/h with only nor splits available engine/mo- SCHWING concrete pumps all of the oil coming from the pump system. In this way the properties and operational
total mass of concrete is 24 strokes/min. That’s 15 % tor output optimally into oil flow for more than 35 years now. hydraulic pump flows pressure- concrete cylinders are “parked” safety. 쑲
pumped. Day by day. Concrete fewer strokes than other pumps and oil pressure and allows the And the open circuit, combined less back to the tank, thereby and support the column of con-
pumps in this class are the true in the same class. concrete pump to run at the with the SCHWING designed making a further contribution crete in the pipeline. No danger
workhorses in the pumping And 15 % fewer strokes means best possible output level. At “Hi-Flow” spool block ensures towards keeping oil tempera- of the concrete slipping back,
industry. 15 % less wear in the valve as- the same time, the manual de- minimum heat generation in the tures low. On SCHWING segregating and overflowing
sembly compared to equivalent stroker valve can be used to hydraulics, therefore negligible pumps, there is no feed pump out of the hopper.
Hydraulics
Direct high-torque drive on to
the agitator shaft as well as
robust design of all hydraulic
The canopy components in conjunction
An eye-catcher on the new with constant flow micro-filter-
SP 1800 is its robust ing of the hydraulic oil ensure
glass-fibre reinforced canopy. operational reliability and a
Such an impact resistant cover long service life.
is rot and rust-proof, is easy to 쑯
keep clean and is logically
maintenance free.
탋
Maintenance
A central bank of grease nip-
ples supplies grease to all of
the lube points on agitator and
Stabilizers Rock valve. 쑲
Four oblique square-tube
stabilizers are anchored into
the pump’s main frame. They
have multi-settings to give the
pump a solid stance even on
uneven ground. Optional
hydraulic stabilizers are also
available and have their cylin-
ders stowed safely under the
pump canopy. Remote control
The SP 1800 comes
쑲
complete with a 10 m cable
remote control as a standard
feature. 쑲
Diesel engine
The diesel version of
SP 1800 utilizes the
newest generation of Deutz
diesel engines. They are
characterized by low noise
emission, low fuel consumption
and exhaust levels complying
with the European Directive
EU-RL 97/68. 쑲