ENVIRONMENTAL PRODUCT DECLARATION
IN ACCORDANCE WITH EN 15804+A2 & ISO 14025 / ISO 21930
Louvres of aluminium
EPD HUB, HUB-1669
Published on 15 July 2024, last updated on 15 July 2024, valid until 15 July 2029.
GENERAL INFORMATION
PRODUCT
MANUFACTURER
Product name Louvres for air intake and outlet
Manufacturer Klimatek
Additional labels V and VK
Address Fabriksvej 16, 7800 Skive, Denmark
Product reference -
Contact details
[email protected] Place of production Skive, Denmark
Website www.klimatek.dk
Period for data 2023
EPD STANDARDS, SCOPE AND VERIFICATION Averaging in EPD No averaging
Program operator EPD Hub,
[email protected] Variation in GWP-fossil for A1-A3 -
Reference standard EN 15804+A2:2019 and ISO 14025
ENVIRONMENTAL DATA SUMMARY
PCR EPD Hub Core PCR version 1.1, 5 Dec 2023
Declared unit 1 kg
Sector Construction product
Declared unit mass 1 kg
Category of EPD Third party verified EPD
GWP-fossil, A1-A3 (kgCO2e) 7.12E+00
Parent EPD number HUB-0840
GWP-total, A1-A3 (kgCO2e) 7.26E+00
Scope of the EPD Cradle to gate with options, A4-A5, and
modules C1-C4, D Secondary material, inputs (%) 1.85
EPD author Alice Andersen Secondary material, outputs (%) 4.55
EPD verification Independent verification of this EPD and data, Total energy use, A1-A3 (kWh) 38.6
according to ISO 14025: Net fresh water use, A1-A3 (m3) 0.04
Internal verification External verification
EPD verifier Haiha Nguyen, as an authorized verifier acting
for EPD Hub Limited
The manufacturer has the sole ownership, liability, and responsibility for
the EPD. EPDs within the same product category but from different
programs may not be comparable. EPDs of construction products may not
be comparable if they do not comply with EN 15804 and if they are not
compared in a building context.
2 V- and VK- louvre
PRODUCT AND MANUFACTURER
BIOGENIC CARBON CONTENT
ABOUT THE MANUFACTURER Product’s biogenic carbon content at the factory gate
Klimatek A/S was founded in 1986 in Denmark and has several years of
experience in manufacturing products for ventilation and climate systems. Biogenic carbon content in product, kg C -
Biogenic carbon content in packaging, kg C 0.016
Klimatek A/S both manufacture standard solutions together with special
solutions and designs depending on the purpose of the product, the actual FUNCTIONAL UNIT AND SERVICE LIFE
construction and architecture. The key products of the production are 1 kg
Declared unit
louvres, dampers, and roof hoods. Klimatek A/S has expertise in producing
products in various types of metals. Mass per declared unit 1 kg
Functional unit -
PRODUCT DESCRIPTION 30 years
Reference service life
The louvres type V and VK are used as intake or outlet for ventilation
systems, aggregates, and cooling systems. The grid is to fit into recesses
or channels, external louvres designed to be used as air intake and SUBSTANCES, REACH - VERY HIGH CONCERN
exhaust air grille. The louvres consist of a mounting frame and a grill The louvres do not contain any REACH and SVHC substances in amounts
insert that is fixed. At the bottom of the louvres is located a drip strip. greater than 0,1 % (1000 ppm).
The louvres come both in standard and custom-made geometry. In
appendix the weights of louvres with standard geometry are illustrated.
This EPD cover louvers made of aluminium. The aluminium comes from
EU and has undergone a quality check before the production.
Further information can be found at www.klimatek.dk.
PRODUCT RAW MATERIAL MAIN COMPOSITION
Raw material category Amount, mass- % Material origin
Metals 100 EU
Minerals - -
Fossil materials - -
Bio-based materials - -
3 V- and VK- louvre
PRODUCT LIFE-CYCLE The louvres are packed depending on the specific size on wood pallets and
with recyclable plastic film around.
SYSTEM BOUNDARY
This EPD covers the life-cycle modules listed in the following table. TRANSPORT AND INSTALLATION (A4-A5)
Product stage Assembly Use stage End of life stage Beyond Transportation impacts occurred from final products delivery to
stage the
system construction site (A4) cover fuel direct exhaust emissions, environmental
boundari impacts of fuel production, as well as related infrastructure emissions.
es
A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
MN MN MN MN MN MN MN The distance of transportation in Denmark corresponds to 200 km in
x x x x X x x x X x
D D D D D D D average based on statistic of the deliveries.
Raw materials
Transport
Manufacturing
Transport
Assembly
Use
Maintenance
Repair
Replacement
Refurbishment
Operational energy use
Operational water use
Deconstr./demol.
Transport
Waste processing
Disposal
Reuse
Recovery
Recycling
The installation of the louvres is by hand tool and typically mounted with
screws (A5). The impact of this process is within the cut-off criteria (< 1%).
PRODUCT USE AND MAINTENANCE (B1-B7)
This EPD does not consider the usage stage.
Modules not declared = MND. Modules not relevant = MNR.
PRODUCT END OF LIFE (C1-C4, D)
MANUFACTURING AND PACKAGING (A1-A3) It is assumed that the energy for deconstruction is 0,1 kWh, and the
The environmental impacts considered for the product stage cover the products will be transported to waste processing by trolly (C1-C2).
manufacturing of materials used in the production as well as packaging Based on the European Aluminium Association, it is assumed that 95% of
materials and other ancillary materials. Also, fuels used by machines, and the aluminium will be recycled in a new product system to substitute virgin
handling of waste formed in the production processes at the materials (C3, D). It is assumed the rest will be for landfill (C3).
manufacturing facilities are included in this stage. This EPD also considers
the material losses occurring during the manufacturing processes. The pallets and plastic for packaging are to go to inclination with energy
recovery (D).
The manufacturing of the louvres takes place at Klimatek A/S in Skive in
Denmark. The core production is cutting, bending, welding, and
assembling of the louvres. The scrap from the production is collected by a
waste handling company and recycled in a subsequent process.
The energy source for the production is from the local electricity grid in
Denmark and wood pellets for heating.
4 V- and VK- louvre
MANUFACTURING PROCESS AND
SYSTEM BOUNDARY
Raw material
and ancillary Packaging
material (A1) material (A1)
Transport Electricity/ Transport
(A2) Heating (A3) (A2)
End of life
(C and D)
Packaging Transport to Installation / Deconstuction
Production of louvres (A3) Use (B1-B7)
(A3) building site (A4) Installation waste (A5) Transport
Waste
Processing
Disposal
Waste sorting and transport (A3)
5 V- and VK- louvre
LIFE-CYCLE ASSESSMENT
AVERAGES AND VARIABILITY
CUT-OFF CRITERIA
Type of average No averaging
The study does not exclude any modules or processes which are stated
mandatory in the reference standard and the applied PCR. The study does Averaging method Not applicable
not exclude any hazardous materials or substances. The study includes all Variation in GWP-fossil for A1-A3 -
major raw material and energy consumption. All inputs and outputs of the
unit processes, for which data is available for, are included in the The EPD contains factory data and does not do any averaging.
calculation. There is no neglected unit process more than 1% of total mass
or energy flows. The module specific total neglected input and output
flows also do not exceed 5% of energy usage or mass. LCA SOFTWARE AND BIBLIOGRAPHY
This EPD has been created using One Click LCA EPD Generator. The LCA and
EPD have been prepared according to the reference standards and ISO
ALLOCATION, ESTIMATES AND ASSUMPTIONS 14040/14044. The EPD Generator uses Ecoinvent v3.8, Plastics Europe,
Allocation is required if some material, energy, and waste data cannot be Federal LCA Commons and One Click LCA databases as sources of
measured separately for the product under investigation. All allocations environmental data.
are done as per the reference standards and the applied PCR. In this study,
allocation has been done in the following ways:
Data type Allocation
Raw materials No allocation
Packaging materials No allocation
Ancillary materials Allocated by mass or volume
Manufacturing energy and
Allocated by mass or volume
waste
6 V- and VK- louvre
ENVIRONMENTAL IMPACT DATA
CORE ENVIRONMENTAL IMPACT INDICATORS – EN 15804+A2, PEF
Impact category Unit A1 A2 A3 A1-A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
GWP – total1) kg CO2e
6,56E+00 4,85E‐02 6,46E‐01 7,26E+00 2,50E‐02 9,49E‐02 MND MND MND MND MND MND MND MNR 4,87E‐03 ‐6,46E‐02 9,39E‐03 ‐4,38E+00
GWP – fossil kg CO2e
6,35E+00 4,85E‐02 7,18E‐01 7,12E+00 2,50E‐02 3,63E‐02 MND MND MND MND MND MND MND MNR 4,87E‐03 1,02E‐02 1,33E‐02 ‐4,29E+00
GWP – biogenic kg CO2e
9,42E‐02 0,00E+00 ‐7,38E‐02 2,04E‐02 9,66E‐06 5,86E‐02 MND MND MND MND MND MND MND MNR 0,00E+00 ‐7,47E‐02 ‐3,93E‐03 0,00E+00
GWP – LULUC kg CO2e
1,19E‐01 1,89E‐05 1,22E‐03 1,21E‐01 9,22E‐06 6,55E‐05 MND MND MND MND MND MND MND MNR 1,81E‐06 5,47E‐06 1,01E‐05 ‐9,54E‐02
Ozone depletion pot. kg CFC-11e
4,86E‐07 1,10E‐08 4,20E‐08 5,39E‐07 5,75E‐09 1,32E‐09 MND MND MND MND MND MND MND MNR 1,12E‐09 4,32E‐10 3,13E‐09 ‐4,45E‐07
Acidification potential mol H+e
5,41E‐02 2,10E‐04 8,88E‐03 6,32E‐02 1,06E‐04 1,40E‐04 MND MND MND MND MND MND MND MNR 2,06E‐05 3,73E‐05 8,38E‐05 ‐2,85E‐02
EP-freshwater2) kg Pe
2,20E‐04 4,08E‐07 3,16E‐05 2,52E‐04 2,05E‐07 2,77E‐06 MND MND MND MND MND MND MND MNR 3,94E‐08 2,38E‐07 2,06E‐07 ‐2,35E‐04
EP-marine kg Ne
6,08E‐03 6,30E‐05 1,85E‐03 8,00E‐03 3,14E‐05 2,66E‐05 MND MND MND MND MND MND MND MNR 6,11E‐06 4,06E‐06 2,73E‐05 ‐3,45E‐03
EP-terrestrial mol Ne
7,00E‐02 6,95E‐04 2,81E‐02 9,88E‐02 3,47E‐04 3,41E‐04 MND MND MND MND MND MND MND MNR 6,74E‐05 4,91E‐05 3,00E‐04 ‐4,01E‐02
POCP (“smog”)3) kg NMVOCe
2,32E‐02 2,21E‐04 6,30E‐03 2,97E‐02 1,11E‐04 8,15E‐05 MND MND MND MND MND MND MND MNR 2,15E‐05 1,43E‐05 9,44E‐05 ‐1,37E‐02
ADP-minerals & metals4) kg Sbe
0,00E+00 1,16E‐07 3,32E‐06 3,44E‐06 5,86E‐08 4,01E‐07 MND MND MND MND MND MND MND MNR 1,19E‐08 4,92E‐07 4,86E‐08 ‐1,11E‐05
ADP-fossil resources MJ
0,00E+00 7,27E‐01 5,86E+00 6,58E+00 3,75E‐01 4,92E‐01 MND MND MND MND MND MND MND MNR 7,31E‐02 6,43E‐02 2,45E‐01 ‐6,61E+01
Water use5) m3e depr.
2,98E+00 3,34E‐03 2,92E‐01 3,28E+00 1,68E‐03 2,36E‐02 MND MND MND MND MND MND MND MNR 3,28E‐04 1,58E‐03 3,57E‐02 ‐8,08E+00
1) GWP = Global Warming Potential; 2) EP = Eutrophication potential. Required characterisation method and data are in kg P-eq. Multiply by 3,07 to get PO4e; 3) POCP = Photochemical ozone formation; 4) ADP = Abiotic depletion
potential; 5) EN 15804+A2 disclaimer for Abiotic depletion and Water use and optional indicators except Particulate matter and Ionizing radiation, human health. The results of these environmental impact indicators shall be used
with care as the uncertainties on these results are high or as there is limited experience with the indicator.
7 V- and VK- louvre
ADDITIONAL (OPTIONAL) ENVIRONMENTAL IMPACT INDICATORS – EN 15804+A2, PEF
Impact category Unit A1 A2 A3 A1-A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
Particulate matter Incidence 6,15E‐07 5,61E‐09 4,95E‐07 1,12E‐06 2,88E‐09 9,68E‐10 MND MND MND MND MND MND MND MNR 5,50E‐10 6,07E‐10 3,00E‐09 ‐3,44E‐07
Ionizing radiation6) kBq U235e 4,51E‐01 3,49E‐03 1,12E‐01 5,67E‐01 1,79E‐03 8,73E‐03 MND MND MND MND MND MND MND MNR 3,51E‐04 7,21E‐04 1,10E‐03 ‐1,23E+00
Ecotoxicity (freshwater) CTUe 1,73E+02 6,55E‐01 3,34E+01 2,07E+02 3,37E‐01 8,00E‐01 MND MND MND MND MND MND MND MNR 6,53E‐02 2,54E‐01 4,92E+00 ‐9,01E+01
Human toxicity, cancer CTUh 1,50E‐08 1,66E‐11 8,10E‐10 1,58E‐08 8,29E‐12 2,08E‐11 MND MND MND MND MND MND MND MNR 1,64E‐12 7,01E‐12 2,34E‐11 ‐2,83E‐08
Human tox. non-cancer CTUh 2,50E‐07 6,48E‐10 3,09E‐08 2,81E‐07 3,34E‐10 6,22E‐10 MND MND MND MND MND MND MND MNR 6,48E‐11 3,08E‐10 4,53E‐10 ‐1,88E‐07
SQP7) - 7,50E+00 8,33E‐01 7,21E+01 8,04E+01 4,32E‐01 5,35E‐01 MND MND MND MND MND MND MND MNR 8,15E‐02 6,24E‐02 3,57E‐01 ‐2,91E+01
6) EN 15804+A2 disclaimer for Ionizing radiation, human health. This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects
due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not
measured by this indicator; 7) SQP = Land use related impacts/soil quality.
USE OF NATURAL RESOURCES
Impact category Unit A1 A2 A3 A1-A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
Renew. PER as energy8) MJ 4,31E+01 8,60E‐03 1,85E+01 6,16E+01 4,23E‐03 3,59E‐01 MND MND MND MND MND MND MND MNR 8,43E‐04 9,38E‐03 4,54E‐03 ‐3,08E+01
Renew. PER as material MJ 0,00E+00 0,00E+00 5,33E‐01 5,33E‐01 0,00E+00 ‐5,33E‐01 MND MND MND MND MND MND MND MNR 0,00E+00 0,00E+00 0,00E+00 0,00E+00
Total use of renew. PER MJ 4,31E+01 8,60E‐03 1,90E+01 6,22E+01 4,23E‐03 ‐1,74E‐01 MND MND MND MND MND MND MND MNR 8,43E‐04 9,38E‐03 4,54E‐03 ‐3,08E+01
Non-re. PER as energy MJ 6,74E+01 7,27E‐01 9,35E+00 7,75E+01 3,75E‐01 4,92E‐01 MND MND MND MND MND MND MND MNR 7,31E‐02 6,42E‐02 2,45E‐01 ‐6,61E+01
Non-re. PER as material MJ 0,00E+00 0,00E+00 1,50E‐01 1,50E‐01 0,00E+00 ‐1,50E‐01 MND MND MND MND MND MND MND MNR 0,00E+00 0,00E+00 0,00E+00 0,00E+00
Total use of non-re. PER MJ 6,74E+01 7,27E‐01 9,50E+00 7,76E+01 3,75E‐01 3,42E‐01 MND MND MND MND MND MND MND MNR 7,31E‐02 6,42E‐02 2,45E‐01 ‐6,61E+01
Secondary materials kg 1,85E‐02 2,14E‐04 2,82E‐03 2,15E‐02 1,04E‐04 1,38E‐04 MND MND MND MND MND MND MND MNR 2,07E‐05 4,19E‐05 3,41E‐04 ‐6,54E‐01
Renew. secondary fuels MJ 0,00E+00 2,06E‐06 2,29E‐04 2,31E‐04 1,05E‐06 9,13E‐07 MND MND MND MND MND MND MND MNR 2,10E‐07 1,56E‐06 7,32E‐06 ‐2,17E‐04
Non-ren. secondary fuels MJ 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 MND MND MND MND MND MND MND MNR 0,00E+00 0,00E+00 0,00E+00 0,00E+00
Use of net fresh water m3 3,47E‐02 9,60E‐05 5,67E‐03 4,04E‐02 4,86E‐05 1,13E‐03 MND MND MND MND MND MND MND MNR 9,45E‐06 4,59E‐05 ‐1,96E‐04 ‐1,79E‐01
8) PER = Primary energy resources.
8 V- and VK- louvre
END OF LIFE – WASTE
Impact category Unit A1 A2 A3 A1-A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
Hazardous waste kg 1,98E+00 9,99E‐04 4,39E‐02 2,02E+00 4,98E‐04 3,53E‐03 MND MND MND MND MND MND MND MNR 9,57E‐05 1,01E‐03 0,00E+00 ‐1,27E+00
Non-hazardous waste kg 9,76E+00 1,64E‐02 1,68E+00 1,15E+01 8,17E‐03 1,21E‐01 MND MND MND MND MND MND MND MNR 1,58E‐03 2,32E‐02 9,50E‐01 ‐1,02E+01
Radioactive waste kg 3,12E‐04 4,86E‐06 3,94E‐05 3,56E‐04 2,51E‐06 2,36E‐06 MND MND MND MND MND MND MND MNR 4,90E‐07 2,58E‐07 0,00E+00 ‐4,19E‐04
END OF LIFE – OUTPUT FLOWS
Impact category Unit A1 A2 A3 A1-A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
Components for re-use kg 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 MND MND MND MND MND MND MND MNR 0,00E+00 0,00E+00 0,00E+00 0,00E+00
Materials for recycling kg 0,00E+00 0,00E+00 1,97E‐01 1,97E‐01 0,00E+00 0,00E+00 MND MND MND MND MND MND MND MNR 0,00E+00 5,00E‐02 0,00E+00 0,00E+00
Materials for energy rec kg 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 2,40E‐01 MND MND MND MND MND MND MND MNR 0,00E+00 0,00E+00 0,00E+00 0,00E+00
Exported energy MJ 0,00E+00 0,00E+00 0,00E+00 0,00E+00 0,00E+00 3,07E‐02 MND MND MND MND MND MND MND MNR 0,00E+00 0,00E+00 0,00E+00 0,00E+00
ENVIRONMENTAL IMPACTS – GWP-GHG - THE INTERNATIONAL EPD SYSTEM
Impact category Unit A1 A2 A3 A1-A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
GWP-GHG9) kg CO2e 6,35E+00 4,85E‐02 7,18E‐01 7,12E+00 2,50E‐02 3,63E‐02 MND MND MND MND MND MND MND MNR 4,87E‐03 1,02E‐02 1,33E‐02 ‐4,29E+00
9) This indicator includes all greenhouse gases excluding biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product as defined by IPCC AR 5 (IPCC 2013). In addition, the characterisation factors for
the flows - CH4 fossil, CH4 biogenic and Dinitrogen monoxide - were updated in line with the guidance of IES PCR 1.2.5 Annex 1. This indicator is identical to the GWP-total of EN 15804:2012+A2:2019 except that the
characterization factor for biogenic CO2 is set to zero.
9 V- and VK- louvre
VERIFICATION STATEMENT I confirm my independence in my role as verifier; I have not been involved
in the execution of the LCA or in the development of the declaration and
VERIFICATION PROCESS FOR THIS EPD have no conflicts of interest regarding this verification.
This EPD has been verified in accordance with ISO 14025 by an independent,
third-party verifier by reviewing results, documents and compliancy with HaiHa Nguyen, as an authorized verifier acting for EPD Hub Limited
reference standard, ISO 14025 and ISO 14040/14044, following the process 15.07.2024
and checklists of the program operator for:
● This Environmental Product Declaration
● The Life-Cycle Assessment used in this EPD
● The digital background data for this EPD
Why does verification transparency matter? Read more online
This EPD has been generated by One Click LCA EPD generator, which has
been verified and approved by the EPD Hub.
THIRD-PARTY VERIFICATION STATEMENT
I hereby confirm that, following detailed examination, I have not established
any relevant deviations by the studied Environmental Product Declaration
(EPD), its LCA and project report, in terms of the data collected and
used in the LCA calculations, the way the LCA-based calculations have been
carried out, the presentation of environmental data in the EPD, and other
additional environmental information, as present with respect to the
procedural and methodological requirements in ISO 14025:2010 and
reference standard.
I confirm that the company-specific data has been examined as regards
plausibility and consistency; the declaration owner is responsible for its
factual integrity and legal compliance.
I confirm that I have sufficient knowledge and experience of construction
products, this specific product category, the construction industry, relevant
standards, and the geographical area of the EPD to carry out this
verification.
10 V- and VK- louvre
APPENDIX
WEIGHT OF LOUVRES
Weight of Standard Sizes (kg)
Height Width (mm)
(mm) 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
300 0,72 0,96 1,2 1,44 1,68 1,92 2,16 2,4 2,64 2,88 3,12 3,36 3,6 3,84 4,08 4,32 4,56
400 0,96 1,28 1,6 1,92 2,24 2,56 2,88 3,2 3,52 3,84 4,16 4,48 4,8 5,12 5,44 5,76 6,08
500 1,2 1,6 2,0 2,4 2,8 3,2 3,6 4,0 4,4 4,8 5,2 5,6 6,0 6,4 6,8 7,2 7,6
600 1,44 1,92 2,4 2,88 3,36 3,84 4,32 4,8 5,28 5,76 6,24 6,72 7,2 7,68 8,16 8,64 9,12
700 1,68 2,24 2,8 3,36 3,92 4,48 5,04 5,6 6,16 6,72 7,28 7,84 8,4 8,96 9,52 10,08 10,64
800 1,92 2,56 3,2 3,84 4,48 5,12 5,76 6,4 7,04 7,68 8,32 8,96 9,6 10,24 10,88 11,52 12,16
900 2,16 2,88 3,6 4,32 5,04 5,76 6,48 7,20 7,92 8,64 9,36 10,08 10,8 11,52 12,24 12,96 13,68
1000 2,40 3,2 4,0 4,32 5,56 6,4 7,2 8,0 8,8 9,6 10,4 11,2 12,0 12,8 13,6 14,4 15,2
1100 2,64 3,52 4,4 5,28 6,16 7,04 7,92 8,8 9,68 10,56 11,44 12,32 13,2 14,08 14,96 15,84 16,72
1200 2,88 3,84 4,8 5,76 6,72 7,68 8,64 9,6 10,56 11,52 12,48 13,44 14,4 15,36 16,32 17,28 18,24
1300 3,12 4,16 5,2 6,24 7,28 8,32 9,36 10,4 11,44 12,48 13,52 14,56 15,6 16,64 17,68 18,72 19,76
1400 3,36 4,48 5,6 6,72 7,84 8,96 10,08 11,2 12,32 13,44 14,56 15,68 16,8 17,92 19,04 20,16 21,28
1500 3,6 4,8 6,0 7,2 8,4 9,6 10,8 12 13,2 14,4 15,6 16,8 18 19,2 20,4 21,6 22,8
1600 3,84 5,12 6,4 7,68 8,96 10,24 11,52 12,8 14,08 15,36 16,64 17,92 19,2 20,48 21,76 23,04 24,32
1700 4,08 5,44 6,8 8,16 9,52 10,88 12,24 13,6 14,96 16,32 17,68 19,04 20,4 21,76 23,12 24,48 25,84
1800 4,32 5,76 7,2 8,64 10,08 11,52 12,96 14,4 15,84 17,28 18,72 20,16 21,6 23,04 24,48 25,92 27,36
1900 4,56 6,08 7,6 9,12 10,64 12,16 13,68 15,2 16,72 18,24 19,76 21,28 22,8 24,32 25,84 27,36 28,88
For special geometry contact Klimatek: [email protected]
11 V- and VK- louvre