Compliance Certification Services (Kunshan) Inc.

Shenzhen Branch

Report No.: FYCR220400004904


Page: 1 of 122

TEST REPORT
Application No.: FYCR2204000049AT
Applicant: Huawei Device Co., Ltd
Address of Applicant: No.2 of Xincheng Road, Songshan Lake Zone, Dongguan, Guangdong,
523808, P.R CHINA.
Manufacturer: Huawei Device Co., Ltd
Address of Manufacturer: No.2 of Xincheng Road, Songshan Lake Zone, Dongguan, Guangdong,
523808, P.R CHINA.
Factory: Weifang Jingwei High Tech Electronic Technology Co., Ltd.
Address of Factory: Photoelectric Industrial Park, No.999 Liyuan Street, Weifang High-Tech
Industrial Development District, Shandong Province, China
Equipment Under Test (EUT):
EUT Name: Wireless Earphone
Model No.: T0012
Trade Mark: HUAWEI
FCC ID: 2ATEYT0012
Standard(s) : 47 CFR Part 15, Subpart C 15.247
Date of Receipt: 2022-04-01
Date of Test: 2022-04-09 to 2022-04-12
Date of Issue: 2022-04-12
Test Result: Pass*
* In the configuration tested, the EUT complied with the standards specified above.

Kidd Yang
EMC Laboratory Manager
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 2 of 122

Revision Record
Version Chapter Date Modifier Remark

01 2022-04-12 Original

Authorized for issue by:

Tree Zhan/Project Engineer

Winkey Wang/Reviewer
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 3 of 122

2 Test Summary
Radio Spectrum Technical Requirement
Item Standard Method Requirement Result
47 CFR Part 15, 47 CFR Part 15, Subpart
Antenna Requirement N/A Pass
Subpart C 15.247 C 15.203 & 15.247(b)(4)

Radio Spectrum Matter Part


Item Standard Method Requirement Result
Conducted Peak ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Pass
Output Power Section 11.9.1 C 15.247(b)(3)
Minimum 6dB ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Pass
Bandwidth Section 11.8.1 C 15.247a(2)
Power Spectrum ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Pass
Density Section 11.10.2 C 15.247(e)
Conducted Band ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Pass
Edges Measurement Section 11.13.3.2 C 15.247(d)
Conducted Spurious 47 CFR Part 15, ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Pass
Emissions Subpart C 15.247 Section 11.11 C 15.247(d)
Radiated Emissions
ANSI C63.10 (2013) 47 CFR Part 15, Subpart
which fall in the Pass
Section 6.10.5 C 15.205 & 15.209
restricted bands
Radiated Spurious
ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Emissions Below Pass
Section 6.4,6.5 C 15.205 & 15.209
1GHz
Radiated Spurious
ANSI C63.10 (2013) 47 CFR Part 15, Subpart
Emissions Above Pass
Section 6.6 C 15.205 & 15.209
1GHz
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 4 of 122

3 Contents
Page
1 COVER PAGE ............................................................................................................................................1

2 TEST SUMMARY .......................................................................................................................................3

3 CONTENTS ................................................................................................................................................4

4 GENERAL INFORMATION ........................................................................................................................6


4.1 DETAILS OF E.U.T. ...............................................................................................................................6
4.2 DESCRIPTION OF SUPPORT UNITS .........................................................................................................6
4.3 MEASUREMENT UNCERTAINTY ..............................................................................................................6
4.4 TEST LOCATION....................................................................................................................................7
4.5 TEST FACILITY......................................................................................................................................7
4.6 DEVIATION FROM STANDARDS ...............................................................................................................7
4.7 ABNORMALITIES FROM STANDARD CONDITIONS .....................................................................................7
5 EQUIPMENT LIST ......................................................................................................................................8

6 RADIO SPECTRUM TECHNICAL REQUIREMENT ...............................................................................13


6.1 ANTENNA REQUIREMENT ....................................................................................................................13
6.1.1 Test Requirement: .......................................................................................................................13
6.1.2 Conclusion ...................................................................................................................................13
7 RADIO SPECTRUM MATTER TEST RESULTS .....................................................................................14
7.1 CONDUCTED PEAK OUTPUT POWER ....................................................................................................14
7.1.1 E.U.T. Operation ..........................................................................................................................14
7.1.2 Test Mode Description .................................................................................................................14
7.1.3 Test Setup Diagram .....................................................................................................................15
7.1.4 Measurement Procedure and Data.............................................................................................15
7.2 MINIMUM 6DB BANDWIDTH ..................................................................................................................16
7.2.1 E.U.T. Operation ..........................................................................................................................16
7.2.2 Test Mode Description .................................................................................................................16
7.2.3 Test Setup Diagram .....................................................................................................................16
7.2.4 Measurement Procedure and Data.............................................................................................16
7.3 POWER SPECTRUM DENSITY...............................................................................................................17
7.3.1 E.U.T. Operation ..........................................................................................................................17
7.3.2 Test Mode Description .................................................................................................................17
7.3.3 Test Setup Diagram .....................................................................................................................17
7.3.4 Measurement Procedure and Data.............................................................................................17
7.4 CONDUCTED BAND EDGES MEASUREMENT ..........................................................................................18
7.4.1 E.U.T. Operation ..........................................................................................................................18
7.4.2 Test Mode Description .................................................................................................................18
7.4.3 Test Setup Diagram .....................................................................................................................19
7.4.4 Measurement Procedure and Data.............................................................................................19
7.5 CONDUCTED SPURIOUS EMISSIONS.....................................................................................................20
7.5.1 E.U.T. Operation ..........................................................................................................................20
7.5.2 Test Mode Description .................................................................................................................20
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 5 of 122
7.5.3 Test Setup Diagram .....................................................................................................................21
7.5.4 Measurement Procedure and Data.............................................................................................21
7.6 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS ..............................................................22
7.6.1 E.U.T. Operation ..........................................................................................................................22
7.6.2 Test Mode Description .................................................................................................................22
7.6.3 Test Setup Diagram .....................................................................................................................23
7.6.4 Measurement Procedure and Data.............................................................................................23
7.7 RADIATED SPURIOUS EMISSIONS BELOW 1GHZ ...................................................................................40
7.7.1 E.U.T. Operation ..........................................................................................................................40
7.7.2 Test Mode Description .................................................................................................................40
7.7.3 Test Setup Diagram .....................................................................................................................41
7.7.4 Measurement Procedure and Data.............................................................................................41
7.8 RADIATED SPURIOUS EMISSIONS ABOVE 1GHZ ...................................................................................50
7.8.1 E.U.T. Operation ..........................................................................................................................50
7.8.2 Test Mode Description .................................................................................................................50
7.8.3 Test Setup Diagram .....................................................................................................................50
7.8.4 Measurement Procedure and Data.............................................................................................51
8 TEST SETUP PHOTO ..............................................................................................................................76

9 EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS) ............................................................................76

10 APPENDIX ................................................................................................................................................77
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 6 of 122

4 General Information
4.1 Details of E.U.T.
Power supply: Left earbud:Rechargeable battery DC 3.82V 55mAh (Charge by charging
box)
Right earbud:Rechargeable battery DC 3.82V 55mAh (Charge by charging
box)
Charging box:Rechargeable battery DC 3.82V 410mAh 1.56Wh (Charge by
Type C)
Cable(s): Type C cable:20cm unshielded
Operation Frequency: 2402MHz to 2480MHz
Bluetooth Version: V5.2 Dual mode
Modulation Type: GFSK
Number of Channels: 40
Channel Spacing: 2MHz
Data rate: 1M/bits and 2M/bits
Antenna Type: Chip Antenna
Antenna Gain: Left earbud-7.1dBi Right earbud:-6.9dBi declared by applicant

4.2 Description of Support Units


Description Manufacturer Model No. Serial No.
-- -- -- --
The EUT has been tested as an independent unit.

4.3 Measurement Uncertainty


Test Item Measurement Uncertainty
Conducted Peak Output Power ± 0.8dB
Minimum 6dB Bandwidth ± 0.3%
Power Spectrum Density ± 0.4dB
Conducted Band Edges Measurement ± 2.7dB
Conducted Spurious Emissions ± 2.7dB
Radiated Emissions which fall in the restricted bands ± 4.4dB (Above 1GHz)
Radiated Spurious Emissions Below 1GHz ± 3.1dB (Below 1GHz)
Radiated Spurious Emissions Above 1GHz ± 4.4dB (Above 1GHz)
Remark:
The Ulab (lab Uncertainty) is less than Ucispr/ETSI (CISPR/ETSI Uncertainty), so the test results
– compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
– non-compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 7 of 122

4.4 Test Location


All tests were performed at:
Compliance Certification Services(Kunshan)Inc. Shenzhen branch.
Fuyong lab. Xinlong TechnoPark,Fengtang Road, Fuyong Subdistrict, Bao’an, Shenzhen, China
Tel: +86 755 8866 3988 Fax: +86 755 2671 0594
No tests were sub-contracted.
4.5 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
• A2LA (Certificate No. 6606.01)
Compliance Certification Services(Kunshan)Inc. Shenzhen branch is accredited by the American
Association for Laboratory Accreditation(A2LA). Certificate No. 6606.01.
• FCC –Designation Number: CN1322
Compliance Certification Services(Kunshan)Inc. Shenzhen branch has been recognized as an
accredited testing laboratory.
Designation Number: CN1322. Test Firm Registration Number: 718073
• Innovation, Science and Economic Development Canada
Compliance Certification Services(Kunshan)Inc. Shenzhen branch has been recognized by ISED
as an accredited testing laboratory.
CAB identifier: CN0129.
IC#: 28189.
4.6 Deviation from Standards
None
4.7 Abnormalities from Standard Conditions
None
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 8 of 122

5 Equipment List
Conducted Peak Output Power
Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Programmable Votsch
Temperature & Humidity Industrietechnik VT 4002 SEM002-15 2021/7/13 2022/7/12
Chamber GmbH
Signal Generator(9kHz-
Agilent N5173B SEM006-05 2021/7/13 2022/7/12
40GHz)
ESG Vector Signal
Generator(250kHz- Agilent E4438C SEM006-15 2021/7/13 2022/7/12
6GHz)
Power Sensor Erika Fiedler U2021XA SEM009-15 2021/7/13 2022/7/12
Power Sensor Erika Fiedler U2021XA SEM009-16 2021/7/13 2022/7/12
Wideband Radio
Rohde & Schwarz CMW 500 SEM010-08 2021/7/13 2022/7/12
Communication Tester
Programmable DC
Chroma 62024P-80-60 SEM011-09 2021/7/13 2022/7/12
Source
Attenuator(18GHz, 6620_SMA-50-
Huber+Suhner SEM021-09 2021/7/13 2022/7/12
20dB, 2W) 1

Minimum 6dB Bandwidth


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Programmable Votsch
Temperature & Humidity Industrietechnik VT 4002 SEM002-15 2021/7/13 2022/7/12
Chamber GmbH
MXA Signal
Analyzer(10Hz- Agilent N9020A SEM004-20 2021/7/13 2022/7/12
26.5GHz)
Signal Generator(9kHz-
Agilent N5173B SEM006-05 2021/7/13 2022/7/12
40GHz)
ESG Vector Signal
Generator(250kHz- Agilent E4438C SEM006-15 2021/7/13 2022/7/12
6GHz)
Power Sensor Erika Fiedler U2021XA SEM009-15 2021/7/13 2022/7/12
Power Sensor Erika Fiedler U2021XA SEM009-16 2021/7/13 2022/7/12
Wideband Radio
Rohde & Schwarz CMW 500 SEM010-08 2021/7/13 2022/7/12
Communication Tester
Programmable DC
Chroma 62024P-80-60 SEM011-09 2021/7/13 2022/7/12
Source
Attenuator(18GHz, 6620_SMA-50-
Huber+Suhner SEM021-09 2021/7/13 2022/7/12
20dB, 2W) 1
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 9 of 122

Power Spectrum Density


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Programmable Votsch
Temperature & Humidity Industrietechnik VT 4002 SEM002-15 2021/7/13 2022/7/12
Chamber GmbH
MXA Signal
Analyzer(10Hz- Agilent N9020A SEM004-20 2021/7/13 2022/7/12
26.5GHz)
Signal Generator(9kHz-
Agilent N5173B SEM006-05 2021/7/13 2022/7/12
40GHz)
ESG Vector Signal
Generator(250kHz- Agilent E4438C SEM006-15 2021/7/13 2022/7/12
6GHz)
Power Sensor Erika Fiedler U2021XA SEM009-15 2021/7/13 2022/7/12
Power Sensor Erika Fiedler U2021XA SEM009-16 2021/7/13 2022/7/12
Wideband Radio
Rohde & Schwarz CMW 500 SEM010-08 2021/7/13 2022/7/12
Communication Tester
Programmable DC
Chroma 62024P-80-60 SEM011-09 2021/7/13 2022/7/12
Source
Attenuator(18GHz, 6620_SMA-50-
Huber+Suhner SEM021-09 2021/7/13 2022/7/12
20dB, 2W) 1

Conducted Band Edges Measurement


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Programmable Votsch
Temperature & Humidity Industrietechnik VT 4002 SEM002-15 2021/7/13 2022/7/12
Chamber GmbH
MXA Signal
Analyzer(10Hz- Agilent N9020A SEM004-20 2021/7/13 2022/7/12
26.5GHz)
Signal Generator(9kHz-
Agilent N5173B SEM006-05 2021/7/13 2022/7/12
40GHz)
ESG Vector Signal
Generator(250kHz- Agilent E4438C SEM006-15 2021/7/13 2022/7/12
6GHz)
Power Sensor Erika Fiedler U2021XA SEM009-15 2021/7/13 2022/7/12
Power Sensor Erika Fiedler U2021XA SEM009-16 2021/7/13 2022/7/12
Wideband Radio
Rohde & Schwarz CMW 500 SEM010-08 2021/7/13 2022/7/12
Communication Tester
Programmable DC
Chroma 62024P-80-60 SEM011-09 2021/7/13 2022/7/12
Source
Attenuator(18GHz, 6620_SMA-50-
Huber+Suhner SEM021-09 2021/7/13 2022/7/12
20dB, 2W) 1
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 10 of 122

Conducted Spurious Emissions


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Programmable Votsch
Temperature & Humidity Industrietechnik VT 4002 SEM002-15 2021/7/13 2022/7/12
Chamber GmbH
MXA Signal
Analyzer(10Hz- Agilent N9020A SEM004-20 2021/7/13 2022/7/12
26.5GHz)
Signal Generator(9kHz-
Agilent N5173B SEM006-05 2021/7/13 2022/7/12
40GHz)
ESG Vector Signal
Generator(250kHz- Agilent E4438C SEM006-15 2021/7/13 2022/7/12
6GHz)
Power Sensor Erika Fiedler U2021XA SEM009-15 2021/7/13 2022/7/12
Power Sensor Erika Fiedler U2021XA SEM009-16 2021/7/13 2022/7/12
Wideband Radio
Rohde & Schwarz CMW 500 SEM010-08 2021/7/13 2022/7/12
Communication Tester
Programmable DC
Chroma 62024P-80-60 SEM011-09 2021/7/13 2022/7/12
Source
Attenuator(18GHz, 6620_SMA-50-
Huber+Suhner SEM021-09 2021/7/13 2022/7/12
20dB, 2W) 1

Radiated Emissions which fall in the restricted bands


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Trilog-Broadband
Schwarzbeck VULB9168 SEM003-33 2021/9/25 2024/9/24
Antenna(25MHz-2GHz)
Biconical
Schwarzbeck VUBA9117 SEM003-35 2021/12/26 2024/12/25
Antenna(150MHz-1GHz)
Loop Antenna(9kHz-
ETS-LINDGREN 6502 SEM003-36 2021/9/26 2024/9/25
30MHz)
MXE EMI receiver(20Hz-
Agilent N9038A SEM004-05 2021/7/13 2022/7/12
8.4GHz)
Pre-amplifier (0.1-
HP 8447D SEM005-02 2021/7/13 2022/7/12
1.3GHz)
Broad-Band Horn
Schwarzbeck BBHA 9170 SEM003-15 2021/7/11 2024/7/10
Antenna (15-40GHz)
Broad-Band Horn
Schwarzbeck BBHA 9120D SEM003-32 2021/9/26 2024/9/25
Antenna (1-18GHz)
Double-ridged
waveguide horn (1- ETS-LINDGREN 3117 SEM003-34 2021/9/25 2024/9/24
18GHz)
Spectrum
Rohde & Schwarz 101288 SEM004-08 2021/7/13 2022/7/12
Analyzer(20Hz-43GHz)
Low Noise BDLNA-0118-
CLAVIIO SEM005-05 2021/7/13 2022/7/12
Amplifier(100MHz- 352810
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 11 of 122
18GHz)
Compliance
Pre-amplifier(26GHz-
Directions Systems PAP-2640-50 SEM005-08 2021/7/13 2022/7/12
40GHz)
Inc.
Pre-amplifier(18GHz-
Rohde & Schwarz CH14-H052 SEM005-17 2021/7/13 2022/7/12
26GHz)

Radiated Spurious Emissions Below 1GHz


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Trilog-Broadband
Schwarzbeck VULB9168 SEM003-33 2021/9/25 2024/9/24
Antenna(25MHz-2GHz)
Biconical
Schwarzbeck VUBA9117 SEM003-35 2021/12/26 2024/12/25
Antenna(150MHz-1GHz)
Loop Antenna(9kHz-
ETS-LINDGREN 6502 SEM003-36 2021/9/26 2024/9/25
30MHz)
MXE EMI receiver(20Hz-
Agilent N9038A SEM004-05 2021/7/13 2022/7/12
8.4GHz)
Pre-amplifier (0.1-
HP 8447D SEM005-02 2021/7/13 2022/7/12
1.3GHz)
Broad-Band Horn
Schwarzbeck BBHA 9170 SEM003-15 2021/7/11 2024/7/10
Antenna (15-40GHz)
Broad-Band Horn
Schwarzbeck BBHA 9120D SEM003-32 2021/9/26 2024/9/25
Antenna (1-18GHz)
Double-ridged
waveguide horn (1- ETS-LINDGREN 3117 SEM003-34 2021/9/25 2024/9/24
18GHz)
Spectrum
Rohde & Schwarz 101288 SEM004-08 2021/7/13 2022/7/12
Analyzer(20Hz-43GHz)
Low Noise
BDLNA-0118-
Amplifier(100MHz- CLAVIIO SEM005-05 2021/7/13 2022/7/12
352810
18GHz)
Compliance
Pre-amplifier(26GHz-
Directions Systems PAP-2640-50 SEM005-08 2021/7/13 2022/7/12
40GHz)
Inc.
Pre-amplifier(18GHz-
Rohde & Schwarz CH14-H052 SEM005-17 2021/7/13 2022/7/12
26GHz)
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 12 of 122

Radiated Spurious Emissions Above 1GHz


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Trilog-Broadband
Schwarzbeck VULB9168 SEM003-33 2021/9/25 2024/9/24
Antenna(25MHz-2GHz)
Biconical
Schwarzbeck VUBA9117 SEM003-35 2021/12/26 2024/12/25
Antenna(150MHz-1GHz)
Loop Antenna(9kHz-
ETS-LINDGREN 6502 SEM003-36 2021/9/26 2024/9/25
30MHz)
MXE EMI receiver(20Hz-
Agilent N9038A SEM004-05 2021/7/13 2022/7/12
8.4GHz)
Pre-amplifier (0.1-
HP 8447D SEM005-02 2021/7/13 2022/7/12
1.3GHz)
Broad-Band Horn
Schwarzbeck BBHA 9170 SEM003-15 2021/7/11 2024/7/10
Antenna (15-40GHz)
Broad-Band Horn
Schwarzbeck BBHA 9120D SEM003-32 2021/9/26 2024/9/25
Antenna (1-18GHz)
Double-ridged
waveguide horn (1- ETS-LINDGREN 3117 SEM003-34 2021/9/25 2024/9/24
18GHz)
Spectrum
Rohde & Schwarz 101288 SEM004-08 2021/7/13 2022/7/12
Analyzer(20Hz-43GHz)
Low Noise
BDLNA-0118-
Amplifier(100MHz- CLAVIIO SEM005-05 2021/7/13 2022/7/12
352810
18GHz)
Compliance
Pre-amplifier(26GHz-
Directions Systems PAP-2640-50 SEM005-08 2021/7/13 2022/7/12
40GHz)
Inc.
Pre-amplifier(18GHz-
Rohde & Schwarz CH14-H052 SEM005-17 2021/7/13 2022/7/12
26GHz)

General used equipment


Equipment Manufacturer Model No Inventory No Cal Date Cal Due Date
Humidity/ Temperature
Mingle TH607 SEM002-22 2021-07-13 2022-07-12
Indicator
Humidity/ Temperature
Mingle TH607 SEM002-23 2021-07-13 2022-07-12
Indicator
Barometer DUMAI DYM3 SEM002-24 2021-07-13 2022-07-12
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 13 of 122

6 Radio Spectrum Technical Requirement

6.1 Antenna Requirement


6.1.1 Test Requirement:
47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4)

6.1.2 Conclusion
15.203 Requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
comply with the provisions of this section. The manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
is prohibited. This requirement does not apply to carrier current devices or to devices operated under
the provisions of 15.211, 15.213, 15.217, 15.219, 15.221, or 15.236. Further, this requirement does
not apply to intentional radiators that must be professionally installed, such as perimeter protection
systems and some field disturbance sensors, or to other intentional radiators which, in accordance
with 15.31(d), must be measured at the installation site. However, the installer shall be responsible
for ensuring that the proper antenna is employed so that the limits in this part are not exceeded.

15.247(b) (4) requirement:


The conducted output power limit specified in paragraph (b) of this section is based on the use of
antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this
section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output
power from the intentional radiator shall be reduced below the stated values in paragraphs (b)(1),
(b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the
antenna exceeds 6 dBi.

EUT Antenna:
The antenna is integrated on the main PCB and no consideration of replacement. The best case gain
of the antenna is Left earbud-7.1dBi Right earbud:-6.9dBi.
Antenna location: Refer to Internal photo.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 14 of 122

7 Radio Spectrum Matter Test Results

7.1 Conducted Peak Output Power


Test Requirement 47 CFR Part 15, Subpart C 15.247(b)(3)
Test Method: ANSI C63.10 (2013) Section 11.9.1

Limit:
Frequency range(MHz) Output power of the intentional radiator(watt)
1 for ≥50 hopping channels
902-928 0.25 for 25≤ hopping channels <50
1 for digital modulation
1 for ≥75 non-overlapping hopping channels
2400-2483.5 0.125 for all other frequency hopping systems
1 for digital modulation
5725-5850 1 for frequency hopping systems and digital modulation

7.1.1 E.U.T. Operation


Operating Environment:
Temperature: 24.1 C Humidity: 57.9 % RH Atmospheric Pressure: 1020 mbar

7.1.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 15 of 122

7.1.3 Test Setup Diagram

7.1.4 Measurement Procedure and Data

Please Refer to Appendix for Details


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 16 of 122

7.2 Minimum 6dB Bandwidth


Test Requirement 47 CFR Part 15, Subpart C 15.247a(2)
Test Method: ANSI C63.10 (2013) Section 11.8.1

Limit:
≥500 kHz

7.2.1 E.U.T. Operation


Operating Environment:
Temperature: 24.1 C Humidity: 57.9 % RH Atmospheric Pressure: 1020 mbar

7.2.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.

7.2.3 Test Setup Diagram

7.2.4 Measurement Procedure and Data

Please Refer to Appendix for Details


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 17 of 122

7.3 Power Spectrum Density


Test Requirement 47 CFR Part 15, Subpart C 15.247(e)
Test Method: ANSI C63.10 (2013) Section 11.10.2

Limit:
≤8dBm in any 3 kHz band during any time interval of continuous transmission

7.3.1 E.U.T. Operation


Operating Environment:
Temperature: 24.1 C Humidity: 57.9 % RH Atmospheric Pressure: 1020 mbar

7.3.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.

7.3.3 Test Setup Diagram

7.3.4 Measurement Procedure and Data

Please Refer to Appendix for Details


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 18 of 122

7.4 Conducted Band Edges Measurement


Test Requirement 47 CFR Part 15, Subpart C 15.247(d)
Test Method: ANSI C63.10 (2013) Section 11.13.3.2

Limit:
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall
be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the
desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
conducted power limits based on the use of RMS averaging over a time interval, as permitted under
paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
emission limits specified in §15.209(a) (see §15.205(c).

7.4.1 E.U.T. Operation


Operating Environment:
Temperature: 24.1 C Humidity: 57.9 % RH Atmospheric Pressure: 1020 mbar

7.4.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 19 of 122

7.4.3 Test Setup Diagram

7.4.4 Measurement Procedure and Data

Please Refer to Appendix for Details


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 20 of 122

7.5 Conducted Spurious Emissions


Test Requirement 47 CFR Part 15, Subpart C 15.247(d)
Test Method: ANSI C63.10 (2013) Section 11.11

Limit:
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall
be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the
desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
conducted power limits based on the use of RMS averaging over a time interval, as permitted under
paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
emission limits specified in §15.209(a) (see §15.205(c).

7.5.1 E.U.T. Operation


Operating Environment:
Temperature: 24.1 C Humidity: 57.9 % RH Atmospheric Pressure: 1020 mbar

7.5.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 21 of 122

7.5.3 Test Setup Diagram

7.5.4 Measurement Procedure and Data

Please Refer to Appendix for Details


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 22 of 122

7.6 Radiated Emissions which fall in the restricted bands


Test Requirement 47 CFR Part 15, Subpart C 15.205 & 15.209
Test Method: ANSI C63.10 (2013) Section 6.10.5
Measurement Distance: 3m

Limit:

Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters)


0.009-0.490 2400/F(kHz) 300
0.490-1.705 24000/F(kHz) 30
1.705-30.0 30 30
30-88 100 3
88-216 150 3
216-960 200 3
Above 960 500 3
Remark: The emission limits shown in the above table are based on measurements employing a CISPR
quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000 MHz.
Radiated emission limits in these three bands are based on measurements employing an average
detector, the peak field strength of any emission shall not exceed the maximum permitted average limits
specified above by more than 20 dB under any condition of modulation.

7.6.1 E.U.T. Operation


Operating Environment:
Temperature: 21.6 C Humidity: 52.3 % RH Atmospheric Pressure: 1020 mbar

7.6.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 23 of 122

7.6.3 Test Setup Diagram

7.6.4 Measurement Procedure and Data


a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at
a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of
the highest radiation.
b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at
a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the
highest radiation.
c. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
the top of a variable-height antenna tower.
d. The antenna height is varied from one meter to four meters above the ground to determine the
maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
to make the measurement.
e. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
the maximum reading.
f. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
Hold Mode.
g. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method
as specified and then reported in a data sheet.
h. Test the EUT in the lowest channel, the middle channel, the Highest channel.
i. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and
found the X axis positioning which it is the worst case.
j. Repeat above procedures until all frequencies measured was complete.
Remark 1: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor
Remark 2: For frequencies above 1GHz, the field strength limits are based on average limits.
However, the peak field strength of any emission shall not exceed the maximum permitted average
limits specified above by more than 20 dB under any condition of modulation. For the emissions
whose peak level is lower than the average limit, only the peak measurement is shown in the report.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 24 of 122

Test Mode: 04; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 25 of 122

Test Mode: 04; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 26 of 122

Test Mode: 04; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 27 of 122

Test Mode: 04; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 28 of 122

Test Mode: 05; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 29 of 122

Test Mode: 05; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 30 of 122

Test Mode: 05; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 31 of 122

Test Mode: 05; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 32 of 122

Test Mode: 06; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 33 of 122

Test Mode: 06; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 34 of 122

Test Mode: 06; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 35 of 122

Test Mode: 06; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 36 of 122

Test Mode: 07; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 37 of 122

Test Mode: 07; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 38 of 122

Test Mode: 07; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 39 of 122

Test Mode: 07; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 40 of 122

7.7 Radiated Spurious Emissions Below 1GHz


Test Requirement 47 CFR Part 15, Subpart C 15.205 & 15.209
Test Method: ANSI C63.10 (2013) Section 6.4,6.5
Measurement Distance: 3m

Limit:
Measurement
Frequency(MHz) Field strength(microvolts/meter)
distance(meters)
0.009-0.490 2400/F(kHz) 300
0.490-1.705 24000/F(kHz) 30
1.705-30.0 30 30
30-88 100 3
88-216 150 3
216-960 200 3
960-1000 500 3

7.7.1 E.U.T. Operation


Operating Environment:
Temperature: 21.6 C Humidity: 52.3 % RH Atmospheric Pressure: 1020 mbar

7.7.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 41 of 122

7.7.3 Test Setup Diagram

7.7.4 Measurement Procedure and Data


a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at
a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of
the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
the top of a variable-height antenna tower.
c. The antenna height is varied from one meter to four meters above the ground to determine the
maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
the maximum reading.
e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
Hold Mode.
f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
did not have 10dB margin would be re-tested one by one using quasi-peak method as specified and
then reported in a data sheet.
g. Test the EUT in the lowest channel, the middle channel, the Highest channel.
h. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and
found the X axis positioning which it is the worst case.
i. Repeat above procedures until all frequencies measured was complete.
Remark:
1. Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor
2. Scan from 9kHz to 30MHz, the disturbance below 30MHz was very low. The points marked on
above plots are the highest emissions could be found when testing, so only above points had been
displayed. The amplitude of spurious emissions from the radiator which are attenuated more than
20dB below the limit need not be reported.
3. The disturbance below 1GHz was very low and the harmonics were the highest point could be
found when testing, so only the above harmonics had been displayed.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 42 of 122

Test Mode: 04; Polarity: Horizontal


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 43 of 122

Test Mode: 04; Polarity: Vertical


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 44 of 122

Test Mode: 05; Polarity: Horizontal


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 45 of 122

Test Mode: 05; Polarity: Vertical


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 46 of 122

Test Mode: 06; Polarity: Horizontal


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 47 of 122

Test Mode: 06; Polarity: Vertical


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 48 of 122

Test Mode: 07; Polarity: Horizontal


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 49 of 122

Test Mode: 07; Polarity: Vertical


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 50 of 122

7.8 Radiated Spurious Emissions Above 1GHz


Test Requirement 47 CFR Part 15, Subpart C 15.205 & 15.209
Test Method: ANSI C63.10 (2013) Section 6.6
Measurement Distance: 3m

Limit:
Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters)
Above 1000 500 3

7.8.1 E.U.T. Operation


Operating Environment:
Temperature: 21.6 C Humidity: 52.3 % RH Atmospheric Pressure: 1020 mbar

7.8.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
TX mode(1Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 04
GFSK modulation.
TX mode(2Mbps)(Left earbud)_Keep the EUT in continuously transmitting mode with
Final test 05
GFSK modulation.
TX mode(1Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 06
with GFSK modulation.
TX mode(2Mbps)(Right earbud)_Keep the EUT in continuously transmitting mode
Final test 07
with GFSK modulation.

7.8.3 Test Setup Diagram


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 51 of 122

7.8.4 Measurement Procedure and Data


a. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at
a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the
highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
the top of a variable-height antenna tower.
c. The antenna height is varied from one meter to four meters above the ground to determine the
maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
the maximum reading.
e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
Hold Mode.
f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
did not have 10dB margin would be re-tested one by one using peak or average method as specified
and then reported in a data sheet.
g. Test the EUT in the lowest channel, the middle channel, the Highest channel.
h. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and
found the X axis positioning which it is the worst case.
i. Repeat above procedures until all frequencies measured was complete.
Remark:
1. Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor
2. Scan from 1GHz to 25GHz, the disturbance above 18GHz was very low. The points marked on
above plots are the highest emissions could be found when testing, so only above points had been
displayed. The amplitude of spurious emissions from the radiator which are attenuated more than
20dB below the limit need not be reported.
3. As shown in this section, for frequencies above 1GHz, the field strength limits are based on
average limits. However, the peak field strength of any emission shall not exceed the maximum
permitted average limits specified above by more than 20 dB under any condition of modulation. For
the emissions whose peak level is lower than the average limit, only the peak measurement is shown
in the report.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 52 of 122

Test Mode: 04; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 53 of 122

Test Mode: 04; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 54 of 122

Test Mode: 04; Polarity: Horizontal; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 55 of 122

Test Mode: 04; Polarity: Vertical; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 56 of 122

Test Mode: 04; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 57 of 122

Test Mode: 04; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 58 of 122

Test Mode: 05; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 59 of 122

Test Mode: 05; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 60 of 122

Test Mode: 05; Polarity: Horizontal; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 61 of 122

Test Mode: 05; Polarity: Vertical; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 62 of 122

Test Mode: 05; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 63 of 122

Test Mode: 05; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 64 of 122

Test Mode: 06; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 65 of 122

Test Mode: 06; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 66 of 122

Test Mode: 06; Polarity: Horizontal; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 67 of 122

Test Mode: 06; Polarity: Vertical; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 68 of 122

Test Mode: 06; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 69 of 122

Test Mode: 06; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 70 of 122

Test Mode: 07; Polarity: Horizontal; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 71 of 122

Test Mode: 07; Polarity: Vertical; Modulation:GFSK; Channel:Low


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 72 of 122

Test Mode: 07; Polarity: Horizontal; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 73 of 122

Test Mode: 07; Polarity: Vertical; Modulation:GFSK; Channel:middle


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 74 of 122

Test Mode: 07; Polarity: Horizontal; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 75 of 122

Test Mode: 07; Polarity: Vertical; Modulation:GFSK; Channel:High


Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 76 of 122

8 Test Setup Photo


Refer to Appendix – Setup Photos for FYCR2204000049AT.

9 EUT Constructional Details (EUT Photos)


Refer to Appendix – External and Internal Photos for FYCR2204000049AT.
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 77 of 122

10 Appendix

For right earbud:

1. Bandwidth
1.1 6dB BW

1.1.1 Test Result

TX Frequency 6dB Bandwidth (MHz)


Mode ANT Verdict
Type (MHz) Result Limit
2402 1 0.663 >=0.5 Pass
1M SISO 2440 1 0.662 >=0.5 Pass
2480 1 0.659 >=0.5 Pass
2402 1 1.147 >=0.5 Pass
2M SISO 2440 1 1.154 >=0.5 Pass
2480 1 1.157 >=0.5 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 78 of 122

1.1.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 79 of 122

1M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 80 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 81 of 122

2M_MCH_2440MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 82 of 122

2. Maximum Conducted Output Power


2.1 Power

2.1.1 Test Result

TX Frequency Maximum Peak Conducted Output Power (dBm)


Mode Verdict
Type (MHz) ANT1 Limit
2402 10.81 <=30 Pass
1M SISO 2440 10.79 <=30 Pass
2480 10.76 <=30 Pass
2402 11.18 <=30 Pass
2M SISO 2440 10.93 <=30 Pass
2480 10.92 <=30 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 83 of 122

3. Maximum Power Spectral Density


3.1 PSD

3.1.1 Test Result

TX Frequency Maximum PSD (dBm/3kHz)


Mode Verdict
Type (MHz) ANT1 Limit
2402 -0.12 <=8 Pass
1M SISO 2440 0.12 <=8 Pass
2480 0.14 <=8 Pass
2402 -0.50 <=8 Pass
2M SISO 2440 -0.23 <=8 Pass
2480 -0.20 <=8 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 84 of 122

3.1.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 85 of 122

1M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 86 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 87 of 122

2M_MCH_2440MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 88 of 122

4. Unwanted Emissions In Non-restricted Frequency Bands


4.1 Ref

4.1.1 Test Result

TX Frequency Level of Reference


Mode ANT
Type (MHz) (dBm)
2402 1 10.69
1M SISO 2440 1 10.98
11.02
2480 1
2402 1 10.75
2M SISO 2440 1 11.06
11.10
2480 1
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 89 of 122

4.1.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 90 of 122

1M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 91 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 92 of 122

2M_MCH_2440MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 93 of 122

4.2 CSE

4.2.1 Test Result

TX Frequency Level of Reference Limit


Mode ANT Verdict
Type (MHz) (dBm) (dBm)
2402 1 11.02 -8.98 Pass
1M SISO 2440 1 11.02 -8.98 Pass
2480 1 11.02 -8.98 Pass
2402 1 11.10 -8.90 Pass
2M SISO 2440 1 11.10 -8.90 Pass
2480 1 11.10 -8.90 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 94 of 122

4.2.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 95 of 122

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 96 of 122

1M_MCH_2440MHz_Ant1_NTNV

1M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 97 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 98 of 122

2M_LCH_2402MHz_Ant1_NTNV

2M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 99 of 122

2M_HCH_2480MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 100 of 122

For left earbud:


1. Bandwidth
1.1 6dB BW

1.1.1 Test Result

TX Frequency 6dB Bandwidth (MHz)


Mode ANT Verdict
Type (MHz) Result Limit
2402 1 0.665 >=0.5 Pass
1M SISO 2440 1 0.662 >=0.5 Pass
2480 1 0.663 >=0.5 Pass
2402 1 1.156 >=0.5 Pass
2M SISO 2440 1 1.150 >=0.5 Pass
2480 1 1.154 >=0.5 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 101 of 122

1.2.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 102 of 122

1M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 103 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 104 of 122

2M_MCH_2440MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 105 of 122

2. Maximum Conducted Output Power


2.1 Power

2.1.1 Test Result

TX Frequency Maximum Peak Conducted Output Power (dBm)


Mode Verdict
Type (MHz) ANT1 Limit
2402 10.91 <=30 Pass
1M SISO 2440 10.84 <=30 Pass
2480 10.98 <=30 Pass
2402 11.02 <=30 Pass
2M SISO 2440 10.97 <=30 Pass
2480 10.94 <=30 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 106 of 122

3. Maximum Power Spectral Density


3.1 PSD

3.1.1 Test Result

TX Frequency Maximum PSD (dBm/3kHz)


Mode Verdict
Type (MHz) ANT1 Limit
2402 3.83 <=8 Pass
1M SISO 2440 4.05 <=8 Pass
2480 4.02 <=8 Pass
2402 3.49 <=8 Pass
2M SISO 2440 3.65 <=8 Pass
2480 3.62 <=8 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 107 of 122

3.1.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 108 of 122

1M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 109 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 110 of 122

2M_MCH_2440MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 111 of 122

4. Unwanted Emissions In Non-restricted Frequency Bands


4.1 Ref

4.1.1 Test Result

TX Frequency Level of Reference


Mode ANT
Type (MHz) (dBm)
2402 1 14.71
14.92
1M SISO 2440 1
2480 1 14.76
2402 1 14.77
14.93
2M SISO 2440 1
2480 1 14.80
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 112 of 122

4.1.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 113 of 122

1M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 114 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 115 of 122

2M_MCH_2440MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 116 of 122

4.2 CSE

4.2.1 Test Result

TX Frequency Level of Reference Limit


Mode ANT Verdict
Type (MHz) (dBm) (dBm)
2402 1 14.92 -5.08 Pass
1M SISO 2440 1 14.92 -5.08 Pass
2480 1 14.92 -5.08 Pass
2402 1 14.93 -5.07 Pass
2M SISO 2440 1 14.93 -5.07 Pass
2480 1 14.93 -5.07 Pass
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 117 of 122

4.2.2 Test Graph

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 118 of 122

1M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 119 of 122

1M_MCH_2440MHz_Ant1_NTNV

1M_HCH_2480MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 120 of 122

1M_HCH_2480MHz_Ant1_NTNV

2M_LCH_2402MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 121 of 122

2M_LCH_2402MHz_Ant1_NTNV

2M_MCH_2440MHz_Ant1_NTNV
Compliance Certification Services (Kunshan) Inc.
Shenzhen Branch

Report No.: FYCR220400004904


Page: 122 of 122

2M_HCH_2480MHz_Ant1_NTNV

2M_HCH_2480MHz_Ant1_NTNV

- End of the Report -