M/S Bhutan Power Corporation Ltd. 15 Mva, 132/33 KV Transformer N P V 0 2 5 1::: Customer Equipment Customer'S Ref No
M/S Bhutan Power Corporation Ltd. 15 Mva, 132/33 KV Transformer N P V 0 2 5 1::: Customer Equipment Customer'S Ref No
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK
-------------------------------------------------
is confidential & should not be used
-------------------------------------------------
without prior consent of
14 BILL OF MATERIAL 0
-------------------------------------------------
15 RTCC1-X1 0
TERMINAL-PLAN
-------------------------------------------------
16 RTCC1-X2 0
TERMINAL-PLAN
-------------------------------------------------
17 RTCC1-X3 0
TERMINAL-PLAN
-------------------------------------------------
18 RTCC1-X4 0
TERMINAL-PLAN
-------------------------------------------------
19 RTCC1-X6 0
TERMINAL-PLAN
-------------------------------------------------
DO NOT MODIFY MANUALLY
DRAWING BY CAD
DATE BY
Crompton Greaves Ltd.
SHEET 1,3,10 MODIFIED ORGN 26.08.2011 DSB
Transformer Division CONTENTS
R1
CHD 26.08.2011 MS Gwalior, India REV SHEET 2
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP R1 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
4.1 POWER
C. X2/17 , & X2/19
CONTROL :2.5 SQ. MM PVC 1100V GRADE
ALARM,INDICATION :1.5 SQ. MM PVC 1100V GRADE
D. X2/20 , & X2/22
AVR AND TRANSDUCER
COLOUR : RED
YELLOW POWER CIRCUIT
BLUE
BLACK CONTROL CIRCUIT
GREY D.C CIRCUIT
All information contained in this document
13. THE TAPCHANGERERS MUST BE IN THE SAME TAP POSTION BEFORE PARALLELING
14. DWG SHOW RTCC1 AS MASTER AND RTCC2 AS FOLLOWER
15. FOR PARALLEL OPERATION
DO NOT MODIFY MANUALLY
1 9 .T H I S D R A W I N G D O E S N O T P U R P O R T T O S H O W T H E E X A C T C O N S T R U C T I O N A L D E T A I L E S O F R T C C A N D T H E L O C A T I O N
OF THE FITTING MAY DIFFER IN THE EXECUTION BASED
DATE BY
Crompton Greaves Ltd. +
TEXT ADDED
ORGN 26.08.2011 DSB Transformer Division GENERAL NOTES
R1
CHD 26.08.2011 MS Gwalior, India REV SHEET 3
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP R1 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L114/10.7
L115/10.7
0 1 1 2
A B
-Q1
L301/6.6
L302/6.6
-K1
I O F M
B2 b a
2 -X2
P1/7.3
2 A2 1
-X2 -SSS
All information contained in this document
/11.1 1 2
is confidential & should not be used
-H1
CROMPTON GREAVES LTD.
I O F M
-X2
4 B1
1 -X2
P2/7.3
A1 3
-SSS
/11.1
-X2
L21/5.1 P3/7.5
5
L26/5.1
-X2
P4/7.5
6
-SSS
I O F M
/11.1
DO NOT MODIFY MANUALLY
C2
L24/6.1
6 D1
D2 5
13 14 L22/5.8
I O F M
12 C1
L29/=30B1/5.1 21 22
DRAWING BY CAD
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division PARALLELING CIRCUIT-MASTER UNIT
CHD 26.08.2011 MS Gwalior, India REV SHEET 4
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
-SSS 15
/11.1 P9/7.3
-X2 A3
-X2
L26/4.8
3
14
B3
I O F M
I O F M
B4
4 17
P10/7.3
18 A4 -X2
-X2 -SSS
/11.1
19
P12/7.5
-X2
F M
-SSS
I O
/11.1
All information contained in this document
21 E2 13 14 G1
is confidential & should not be used
-X2 8 F2 F1 7 20
P11/7.3
G2 -OSR E1 -X2
CROMPTON GREAVES LTD.
without prior consent of
I O F M
.5
-SSS
/11.1
-X2 22 12
L72/=30B1/6.6 P7/7.5
11
L71/=30B1/6.6
-X2 13
L73/=30B1/6.6 P8/7.5
P13/7.3
-SSS
/11.1
A1 A2
18 N1
P1
-OSR
I O F M
/12.6
-SSS
DO NOT MODIFY MANUALLY
. 4. 6
15
/11.1 -TDR2
61 62
15
25
13 TDR2
L21/4.1 -OSR
J1 A2 A1
.5 -TDR2
16
18
28
26
I O F M
DRAWING BY CAD
-OSL
18 2 1
2 1
-OSBZ
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division PARALLELING CIRCUIT-MASTER UNIT
CHD 26.08.2011 MS Gwalior, India REV SHEET 5
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK
L120/=30B3/7.2
L121/=30B3/7.2
L24/4.1
-SSS 5 6
/11.1 L1 13
-OSR
L25
20 /5.5 -X1
M1 34 33
I O F M
5 6 10
10
12
12
4 4
L301/4.3
-X2
P5/7.5
3 3 7
L302/4.3
All information contained in this document
is confidential & should not be used
2 1
9 9
AVR -X3
PT
8
P6/7.5
CROMPTON GREAVES LTD.
O/P
without prior consent of
11 1 2
11
14 14
L49/12.6
U
13 13
L50/12.6
43
-CSS2 -OSR
-A1 /5.5 44
2 AUTO
3 MANUAL 23
-X1 -OSR
2
L4/=30B1/5.1 /5.5 24
1
6
3
-RLS -LLS
DO NOT MODIFY MANUALLY
3
L2/=30B1/5.4
14 13 14 13
RAISE LOWER -X1
DRAWING BY CAD
4
L1/=30B1/5.4
-X1
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division AUTO CONTROL OF OLTC D.M1
CHD 26.08.2011 MS Gwalior, India REV SHEET 6
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK 20
-X2
-X2
1
10
P13/5.1
-X2
-X2
-X2 3
P1/4.8
2
-X2
P3/4.8
5
-X2
P2/4.8
4
-X2
P4/4.8
6
-X2
P5/6.8
All information contained in this document
7
is confidential & should not be used
P6/6.8
8
CROMPTON GREAVES LTD.
without prior consent of
P7/5.6
9 12
-X2 P8/5.6
13
-X2
P9/5.8
14 15
-X2
18 16
P10/5.8
-X2 -X2
17
-X2
19
DO NOT MODIFY MANUALLY
-X2
P12/5.8
21
P11/5.8
-X2 22
L30.
DRAWING BY CAD
-X1
RTCC2-FOLLOWER UNIT
DATE BY
Crompton Greaves Ltd. +RTCC2
ORGN 26.08.2011 DSB Transformer Division PARALLELING CIRCUIT-FOLLOWER UNIT
CHD 26.08.2011 MS Gwalior, India REV SHEET 7
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L126/=30B1/7.3
L81/=30B3/5.2
31
L123/=30B1/7.2
L124/=30B1/7.2
L125/=30B1/7.3
L94/=30B3/5.2
-K1
32
DC SUPPLY ON
7
2 3 4
All information contained in this document
is confidential & should not be used
1 1 1 1 1 1
CROMPTON GREAVES LTD.
+ IVE
2 2 2 2 2 2
L102/12.1
- IVE
8
1
2
3
4
5
6
7
1
2
3
4
5
6
7
LV REMOTE WINDING TEMPRATURE INDICATOR HV REMOTE WINDING TEMPRATURE INDICATOR
-P1 -P2
14
14
15
16
15
16
9 10 9 10
E E
DO NOT MODIFY MANUALLY
1 3
9 19
10 20
DRAWING BY CAD
2 4
-F12
L301/=30B3/9.4
L302/=30B3/9.4
L303/=30B3/9.7
L304/=30B3/9.7
-X1 16 17
220 VOLT DC
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division INDICATION CIRCUIT
CHD 26.08.2011 MS Gwalior, India REV SHEET 8
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK
4-20 mA O/P
-X1
FOR SCADA
7 5 L114/4.4
21 -TPI
-X1 6 4 L115/4.4
3 1 2
22
-RLS -LLS
/6.5 /6.6
L505/=30B3/5.6
-X1
L36/=30B1/5.1
-X1 7 8 9 20
L506/=30B3/5.6
-X1 15
L61/=30B1/6.3
L62/=30B1/6.4
L63/=30B1/6.4
-X1 14
-LF
-H4
1
CROMPTON GREAVES LTD.
1
without prior consent of
A
-HS A1
1 2
-TDR1 1 1
-DS A2
2
-B1
4
2 -H5 18
1
15
-E3 -TDR1
1
2 .6
-E2
DO NOT MODIFY MANUALLY
18
15
16 .8
DRAWING BY CAD
-X1 11
28
25
26 /12.3
L122/=30B1/5.5
DATE BY
Crompton Greaves Ltd. +RTCC1
TPI MODIFIED
ORGN 26.08.2011 DSB Transformer Division HEATER & ILLUMINATION
R1
CHD 26.08.2011 MS Gwalior, India CIRCUIT REV SHEET 10
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP R1 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK
/4.6
/4.2
/5.2
/5.4
/4.6
/4.2
/5.7
/5.2
/5.5
/5.2
-SSS
All information contained in this document
is confidential & should not be used
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division device configration
CHD 26.08.2011 MS Gwalior, India REV SHEET 11
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK
ANNUNCIATOR HOOTER
-ANN
1 2 -H6
-
AT SILENCE
AT ANNUNCIATOR 10 WINDOW ACCEPT
L101/8.7 P RESET
L102/8.7 N OPERATION
CC 1C 2C 3C 4C 5C 6C 7C 8C 9C 10C CC G
All information contained in this document
is confidential & should not be used
SPARE WINDOW
without prior consent of
5
L151/=30B1/7.4
OLTC TRIP
6
L152/=30B1/7.4
-X4
41 42
-TDR1
TAP CHANGE / 1 02 5. 6 2 8
DO NOT MODIFY MANUALLY
INCOMPLETE
L49/6.6
AVR FAIL
L50/6.6
DRAWING BY CAD
OUT OF STEP
-TDR2 RELAY OPERATED
/ 52.56 28
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division INDICATION CIRCUIT
CHD 26.08.2011 MS Gwalior, India REV SHEET 12
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
IF IN DOUBT, ASK -
+ 3
600
600 610
50
E3 E3 -
+ 3
PANEL
510
DS IDELNTITY LABEL DS
CROMPTON
NAME PLATE 610
P1 TPI P2
ANN OSBZ
LK LF 50
FRONT
FOUNDATION BOLT
SIDE
H1 H4 H5 H7 H8
TDR1
FOUNDATION DETAIL
is confidential & should not be used
HS Q1
RLS
2000
X4 X1
NOTES :
X2
CSS2
SSS S1 1) FINISH- EXTERIOR = SHADE : 631 SYNC. ENAMEL
INTERIOR = GLOSSY WHITE
X6 DOOR AT REER
A1
3) THE DOOR HAS HANDLE OPERATED LATCHES & HANDLE
IS PROVIDED WITH CENTER LOCK
X3 4). PROTECTION CLASS:-IP 42
DO NOT MODIFY MANUALLY
EARTHING
B1 TERMINAL
E2
DRAWING BY CAD
100
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division GENERAL ARRANGEMENT OF REMOTE
CHD 26.08.2011 MS Gwalior, India TAPCHANGE CONTROL CUBICLE REV SHEET 13
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DEV. ID. TECHNICAL DESCRIPTION MAKE DEV. ID. TECHNICAL DESCRIPTION MAKE
IF IN DOUBT, ASK LOCATION
PAGE.COLUMN
RATING CATALOG NO. LOCATION
PAGE.COLUMN
RATING CATALOG NO.
-----------------------------------------------------------------------
-A1 6.4 AVR EMCO/EQ. -H32 8.5 AUTO SUPPLY CHANGEOVER TEKNIC/EQ.
+RTCC1 WITH LDC ARRGT EE-301M +RTCC1 220VDC, LED CLUSTER
----------------------------------------------------------------------- -----------------------------------------------------------------------
-ANN 12.4 ANNUNCIATOR MINILEC/BHARANI -HS 10.2 HEATER SWITCH RECOM/SURAJ/EQ.
+RTCC1 90-240V AC/DC 10W /EQ. +RTCC1 6 AMPS /ANCHOR/KAYCEE
----------------------------------------------------------------------- -----------------------------------------------------------------------
-B1 10.2 THERMOSTAT GIRISH/EQ. -K1 4.4 CONTACTOR SIEMENS/L&T/
+RTCC1 30 C TO 85 C +RTCC1 1 POWER + 1 NO + 1 NC CONTACT SCHNIEDER/EQ.
----------------------------------------------------------------------- 6A,415VAC,110VAC COIL
-CSS2 6.3 AUTO MANUAL SWITCH/ SWITRON/KAYCEE -----------------------------------------------------------------------
+RTCC1 1 POLE 2 WAY,PISTOL GRIP /ANCHOR/EQ. -LF 10.1 FUSE LINK HRC SIEMENS/EQ.
6A,250V AC +RTCC1 2A,415V AC 3NW NS2
----------------------------------------------------------------------- -----------------------------------------------------------------------
-DS 10.2 DOOR SWITCH KAYCEE/SURAJ/ -LK 10.1 LINK SIEMENS/EQ.
+RTCC1 1 NC CONTACT RAJ/EQ. +RTCC1
230 V AC -----------------------------------------------------------------------
----------------------------------------------------------------------- -OSBZ 5.7 BUZZER ALAN/EQ.
-E2 10.2 HEATER RK/GIRISH/JAYSHR +RTCC1 110V AC
+RTCC1 230V AC 40W EE/EQ. -----------------------------------------------------------------------
----------------------------------------------------------------------- -OSL 5.7 TEKNIC/EQ.
-E3 10.2 ILLUMINATION LAMP CGL/EQ. +RTCC1 SIGNAL LAMP-RED
+RTCC1 240V 11W CFL 2.5W,110V AC
All information contained in this document
----------------------------------------------------------------------- -----------------------------------------------------------------------
is confidential & should not be used
-F12 8.1 MINIATURE CIRCUIT BREAKER SIEMENS/L&T/EQ. -OSR 5.5 OUT OF STEP RELAY/ SIEMENS/L&T/
+RTCC1 2POLE /SCHINDER +RTCC1 6A,415VAC,110VAC COIL SCHINDER/EQ.
6A,415V AC/220V DC -----------------------------------------------------------------------
CROMPTON GREAVES LTD.
without prior consent of
----------------------------------------------------------------------- -----------------------------------------------------------------------
-H7 8.3 UPPER LIMIT REACHED TEKNIC/EQ. -SSS 11.1 SEOENCE SELECTOR SWITCH KAYCEE/EQ.
+RTCC1 220VDC, LED CLUSTER +RTCC1
----------------------------------------------------------------------- -----------------------------------------------------------------------
-H8 8.4 LOWER LIMIT REACHED TEKNIC/EQ. -TDR1 10.6 TIME DELAY RELAY ELECTRONIC EAPL/EQ
DRAWING BY CAD
Cross section
IF IN DOUBT, ASK TERMINAL BLOCK +RTCC1-X1
*
CABLE
Destination Destination
Cable
Internal External
Type
Cross- Terminal-
Wire- Bridge Number Wire-
+LOC -DID :CP reference +LOC -DID :CP
Remarks
No.
No.
description Pg.Col description
-Q1 1 4.2 1 +DM11 -X1 6
-Q1 2 4.2 2 +DM11 -X1 5
-OSR 44 6.7 3 +DM11 -X1 9
-OSR 24 6.7 4 +DM11 -X1 8
-SSS 5 4.7 5 +DM11 -X1 10
-CSS21 6.2 6 +DM11 -X1 14
-TPI 3 10.3 7 +DM11 -X1 11
-TPI 1 10.4 8 +DM11 -X1 12
-TPI 2 10.4 9 +DM11 -X1 13
-S1 1 4.3 10 +DM11 -X1 40
All information contained in this document
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division RTCC1-X1
CHD 26.08.2011 MS Gwalior, India TERMINAL-PLAN REV SHEET 15
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Cross section
IF IN DOUBT, ASK TERMINAL BLOCK +RTCC1-X2
*
CABLE
Destination Destination
Cable
Internal External
Type
Cross- Terminal-
Wire- Bridge Number Wire-
+LOC -DID :CP reference +LOC -DID :CP
Remarks
No.
No.
description Pg.Col description
-SSS 2 4.8 1 +RTCC2 -X2 2
4.1 2 -SSS A2
-SSS 1 4.8 3 +RTCC2 -X2 4
4.1 4 -SSS A1
-SSS D2 4.8 14 5
-SSS D1 4.8 6 +RTCC2 -X2 3
-OSR 23 6.8 7 +RTCC2 -X2 7
-OSR 43 6.8 8 +RTCC2 -X2 8
9
10
All information contained in this document
5.2 5 14 -SSS 3
-SSS A3 5.8 15 +RTCC2 -X2 14
16
-SSS 4 5.8 17 +RTCC2 -X2 18
5.1 18 -SSS A4
-SSS G1 5.8 19 +RTCC2 -X2 19
-SSS 7 5.8 20 +RTCC2 -X2 21
5.1 21 -SSS 8
5.1 22 +RTCC2 -X2 10
DO NOT MODIFY MANUALLY
DRAWING BY CAD
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division RTCC1-X2
CHD 26.08.2011 MS Gwalior, India TERMINAL-PLAN REV SHEET 16
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Cross section
IF IN DOUBT, ASK TERMINAL BLOCK +RTCC1-X3
*
CABLE
Destination Destination
Cable
Internal External
Type
Cross- Terminal-
Wire- Bridge Number Wire-
+LOC -DID :CP reference +LOC -DID :CP
Remarks
No.
No.
description Pg.Col description
-A1 2 6.5 1
-A1 1 6.5 2
-A1 3 6.5 3 -Q1 B
-A1 4 6.5 4 -Q1 A
-A1 5 6.5 5 +M.BOX -X2 29
-A1 6 6.5 6 +M.BOX -X2 30
7
8
6.4 11 9 -A1 9
-A1 10 6.5 10 -LLS 13
All information contained in this document
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division RTCC1-X3
CHD 26.08.2011 MS Gwalior, India TERMINAL-PLAN REV SHEET 17
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Cross section
IF IN DOUBT, ASK TERMINAL BLOCK +RTCC1-X4
*
CABLE
Destination Destination
Cable
Internal External
Type
Cross- Terminal-
Wire- Bridge Number Wire-
+LOC -DID :CP reference +LOC -DID :CP
Remarks
No.
No.
description Pg.Col description
-F12 1 8.1 1 +M.BOX -X4 1
-H28 1 8.3 2 +DM11 -X1 15
-H7 1 8.3 3 +DM11 -X1 16
-H8 1 8.4 4 +DM11 -X1 17
-ANN CC 12.3 5 +DM11 -X1 23
-ANN 1C 12.3 6 +DM11 -X1 24
-H32 1 8.5 7 +M.BOX -X4 2
All information contained in this document
is confidential & should not be used
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division RTCC1-X4
CHD 26.08.2011 MS Gwalior, India TERMINAL-PLAN REV SHEET 18
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Cross section
IF IN DOUBT, ASK TERMINAL BLOCK +RTCC1-X6
*
CABLE
Destination Destination
Cable
Internal External
Type
Cross- Terminal-
Wire- Bridge Number Wire-
+LOC -DID :CP reference +LOC -DID :CP
Remarks
No.
No.
description Pg.Col description
8.4 1 -P1 1
8.4 2 -P1 2
8.4 3 -P1 3
8.4 4 -P1 4
8.4 5 -P1 5
8.4 6 -P1 6
8.4 7 -P1 7
8.4 8 -P1 8
-P1 9 8.4 9 +M.BOX -X2 37
-P1 10 8.4 10 +M.BOX -X2 38
All information contained in this document
8.5 11 -P2 1
is confidential & should not be used
8.5 12 -P2 2
8.5 13 -P2 3
CROMPTON GREAVES LTD.
without prior consent of
8.6 14 -P2 4
8.6 15 -P2 5
8.6 16 -P2 6
8.6 17 -P2 7
8.6 18 -P2 8
-P2 9 8.5 19 +M.BOX -X2 43
-P2 10 8.5 20 +M.BOX -X2 42
DO NOT MODIFY MANUALLY
DRAWING BY CAD
DATE BY
Crompton Greaves Ltd. +RTCC1
ORGN 26.08.2011 DSB Transformer Division RTCC1-X6
CHD 26.08.2011 MS Gwalior, India TERMINAL-PLAN REV SHEET 19
DRG No.: M30B2 7501E
NO REVISION DATE APPD 26.08.2011 RP 0 18 SH
1 2 3 4 5 6 7 8