PT.

SURYA PAMENANG
KEDIRI - INDONESIA

Nomer : S2327
Periode : 07 Juli -…...Agustus 2023

Prior
No. Mesin Uraian Pekerjaan

7 8 9

Waktu Pelaksanaan ( Hari )


Alokasi Man Power ( Orang )
Total Kebutuhan Waktu ( Menit )
Manday ( Jam / Hari )
SEKSI PROCESS CONTROL
SHIFT-1
1 120-HT1505 Commissioning Infrared bersama seksi terkait 1
2 120-SN6001 Preventive Maintenance Threader Pan Reel 1
- Check dan Test Limit Swtch
- Test System
3 120-060A Preventive Maintenance Device Reel 1
- Check dan Test Limit Swicth, PX & Photo Detector
- Perkuat SupporT Device
- Rapikan Kabel & Condoit Flexible
4 120-AJ3005 Preventive Maintenance Scanner Reel 1
- Cleaning Beam dan Sensor Head
- Cleaning filter water cooling PMP
- Cleaning filter water cooling Scanner
- Cleaning Filter Blower Scanner
- Cleaning photo cell scanner off sheet
- Beri pelindung plastik
5 122-TFFWFS Penambahan Jalur Pengencer Tank F2 Dari Fresh Water 1
- Pasang Selector Swicth Di Bencboard K0-B1 & Wiring
- Modifikasi wiring dan pasang Relay untuk soleoid valve G5.02
- Install Cable untuk Solenoid Valve Jalur pengencer ke Tanki F2 ( dari Panel K0-F1 ke Panel 122-F15)
- Penambahan program & Testing
6 122-F1 Penambahan Program Timer Delay Saat On-OFF Coating Untuk SV F1.08/09 Dan F2.08/09 & Testing 1

7 120-HT1505 Preventive Maintenance Infra Red #1,2,3 1


- Cleaning Busi,flame detector & mixing block
- Check, ganti indicator lamp Panel IR (jika lampu mati)
- Setting dan Test limit switch hood
- Lengkapi Label Device
8 120-AJ3001 Preventive Maintenance Scanner Size Press 1
- Ganti Motor Scanner
- Check Roller
- Check Alignment Head
- Test Scanner
9 120-GT2307 Preventive Maintenance Limit Switch Alarm Felt Area Wire & Press (sesuai checklist) 1
- Check Limit Switch, perkuat wiring, perkuat support, perkuat stick & Test contact
- Adjust Limit Switch dan Ganti plastik pelindung
- Check Wiring Fuse ( disamakan dengan Original Drawiing)
10 120-AJ3003 Preventive Maintenance Scanner 1st Coater Tahap 1 1
- Check Cable Powertrack Bottom Head, Karena ada beberapa kabel yang putus
120-GT2307 Preventive Maintenance Limit Switch Alarm Felt Area Dryer (sesuai checklist) 1
- Check Limit Switch, perkuat wiring, perkuat support, perkuat stick & Test contact
- Adjust Limit Switch dan Ganti plastik pelindung
11 120-AJ3003 Preventive Maintenance Scanner 1st Coater Tahap 2 1
- Check Cable Powertrack Bottom Head, Karena ada beberapa kabel yang putus
12 120-WIS Preventive Maintenance WIS 1
- Bersihkan Camera Beam 1 & Lamp Beam 1
- Bersihkan Camera Beam 2 , Lamp Beam 2, & Lamp Beam 3
- Pasang Cover pelindung Camera Beam 2 ( karena akan libur Total )
- Bersihkan Filter Chiller 1, & 2
- Check Level Water Chiller
- Bersihkan Komputer, keyboard & Rapikan Kabel
- Pasang Plastik Pelindung
13 122-L1a Preventive Maintenance Cable Level Control Tank L1A 1
- Instalasi Ulang kabel level L1A Dari Transmitter ke JB
14 120-AJ3002 Preventive Maintenance Scanner Base Sheet 1
- Kembalikan Sensor Belows Caliper yang lama top/bottom, Karena Sensor yang lama sudah selesai diperbaiki
- Test Sensor Caliper
- Test Card temperature ex.pakai
- Check Ground Wire Slider
- Check Quick Coupling Cooling Water
15 120-D3-022D Persiapan Upgrade Control & Motor 3RD Dryer Top -Bottom 1
- Pembuatan jalur Kabel encoder
- Instalasi kabel Encoder
16 120- Preventive Maintenance Calcoil 1
- Check dan Perbaikan Harmaflex
- Test Card Power Module Callcoil ex.repair
- Check Limit Switch Interlock
- Check dan Bersihkan Filter Blower
17 132-TF2810/1 Preventive Maintenance Panel Demin Area Boiler 1
- Penggantian PLC, Wiring & Testing
18 132-TF2810/1 Penggantian Junktion Box Panel Demin Boiler 1
19 120- Preventive Maintenance Auto Slice 1
- Bersihkan Module Display
- Check dan perkuat Kabel Connector
- Test Card ex.pakai
20 122- Prev. Maintenance Limit Switch dan Selector Switch cleaning area Kitchen (sesuai list) 1
- Check, test LS dan SS (lihat respon di card PLC atau di Komputer)
21 122- Prev. Maintenance Limit Switch, dan Selector switch cleaning area Final (sesuai list) 1
- Check, test LS, dan SS (lihat respon di card PLC atau di Komputer)
22 121-JT1021 Preventive Maintenance Junktrap 1021, 1040,1041, 2050, 3021 1
- Check dan Bongkar Limit switch Dump Valve & Isolation Valve
- Rapikan Kabel LS
- Ganti Plastik Pelindung
- Lengkapi Label Device
23 121-JT3040 Preventive Maintenance Junktrap 3040, 3041,3042, 4040, 4041 & 4042 1
- Check dan Bongkar Limit switch Dump Valve & Isolation Valve
- Rapikan Kabel LS
- Ganti Plastik Pelindung
- Lengkapi Label Device
24 121-JT4090 Preventive Maintenance Junktrap 4090,4091,4092, 4093, 4094, 4095, 4096 & 4097 1
- Check dan Bongkar Limit switch Dump Valve & Isolation Valve
- Rapikan Kabel LS
- Ganti Plastik Pelindung
- Lengkapi Label Device
25 121- Preventive Maintenance Panel -Panel DDR 1
- Rapikan kabel Limit Switch Maximal OUT
- Check lamp indicator local panel
- Check dan bersihkan panel Contactor
- Check dan Test Indicator Low Packing Water
26 121-PO4312 Preventive maintenance Panel Polydisk 2 1
- Check PB, SS, Potensio Ref. & PX Motion sensor
- Check dan Test Lampu indikator
- Check lampu alarm
- Perkuat Wiring kabel di local box & VS Drive
27 121- Preventive Maintenance Panel Komputer DCS Area Control Room StockPrep. 1
- Bersihkan Panel & Komputer
- Brsihkan Filter Fan
- Check dan Perkuat Wiring
- Rapikan Kabel
28 120-CN1011/1 Preventive Maintenance Panel Kinomatic & Sensor Alarm ( Wire Cleaning & Press ) 1
- Bersihkan Panel
- Perkuat Wiring kabel Control
- Check, Test & Setting Sensor Alarm Kinomatic
29 120-80TT Preventive Maintenance Panel PCF & Sensor2 PCF ( Belbond 1 & 2) 1
- Bersihkan Panel
- Perkuat Wiring kabel Control
- Check, & Test Proximity Park Position + Proximity Counter
- Lengkapi Label Device
30 120-VR4500/5 Preventive Maintenance Fibron Size Press, 1st Calender & 1st Coater 1
- Check dan Test Device (LS, PX)
- Check indicator Lamp
- Perkuat wiring cable control di VS Drive
31 120-D3-W1 Preventive Maintenance Tail Cutter 3rd Dryer- 3rd Pustack 1
- Check PB, Emergency & Lampu indicator
- Check PX Home Posisi
- Perkuat Wiring
32 120- Preventive Maintenance Panel Power Module MCC BMB 1
- Check dan perkuat wiring
- Chech dan Ganti Label MCB yang kusam
- Rapikan kabel Duct
33 120- Preventive Maintenance Panel-Panel Separator 1
- Check dan perkuat wiring
- Check dan Test PB + Indicator Lamp
- Ganti Plastik Pelindung
34 120- Preventive Maintenance ALL Resolver DC Drive 1
- Check baut Torsi Coupling Resolver
- Bersihkan dari kotoran Grease
- Lengkapi pelindung
35 120- Preventive Maintenance Tension Display DC Drive 1
- Check Belt tension TR1-TR13
- Verifikasi Display Tension
36 122- Follow up Penambahan Interlock Power On Motor kimia Area Wet-End 1
- Instalasi kabel Control untuk Start Contactor
- Penamban program interlock dengan Run System
- Test Program
37 122- Preventive Maintenance Local Box Area Kitchen Coating Lantai 2 1
- Bersihkan Panel
- Ganti Plastik Pelindung
- Perkuat wiring

SHIFT-2
38 120-AJ3002 Preventive Maintenance Scanner Sze Press & Base Sheet 1
- Cleaning Beam dan Sensor Head
- Cleaning filter water cooling PMP
- Cleaning filter water cooling Scanner
- Cleaning Filter Blower
- Cleaning photo cell scanner off sheet
- Beri pelindung plastik
39 123-CU1015 Preventive Maintenance Mesin Rewinder 1
- Penggantian cable moving device Core Chuck & Core Slide Back side
- Rewiring & Testing
40 120- Preventive Maintenance Resolver DC Drive 1
- Ganti Resolver MH#02
- Ganti Resolver TR05, TR07, TR08, TR09, TR10, TR11 & TR13
41 120-HT1564 Preventive Maintenance Aircap #2 & 3 (Sesuai checklist) 1
- Cleaning busi & housing
- Cleaning Flame detector
- Check dan test LS Aircap Raise/Lower, LS high fire/low fire
- Check lamp indicator
42 120-GT2307 Preventive Maintenance Panel View 1
- Check dan ganti mika plastik pelindung (jika plastik masih baik, tidak perlu diganti)
43 120-P-B1 Prev. Maintenance Bench Board PLC Wet end Area Front side (PB1 S/D R-B1) 1
- Bersihkan panel ( dengan vacuum cleaner )
- Bersihkan filter Fan, ganti Filter Cooling
- Test indicator Lamp
44 120-P-F1 Prev. Maintenance Panel-Panel PLC Wet end Area Back side (PF1 S/D K3-F1) 1
- Bersihkan panel (dengan vacuum cleaner)
- Bersihkan filter Fan, ganti Filter Cooling
- Test indicator Lamp
45 120-P1-H1 Prev. Maintenance Panel2 PLC area BMB Lantai 1 (P1-H1, L-H0, C1-H1, C1-H2 1
C1-H3, LH-6, C2-H1, N-W1)
- Bersihkan panel ( dengan vacuum cleaner )
- Bersihkan filter Fan, ganti Filter Cooling
- Test indicator Lamp
- Ganti plastik pelindung
46 120-LF2506 Preventive Maintenance Device Coater Rope Stretcher 1
- Check, test device Limit switch
- Check, test device safety motion Sensor Rope
- Ganti Plastik Pelindung
47 120-LF2506 Preventive Maintenance Device 1ST Coater Head -3RD Coater Head 1
-Bongkar LS K1HR, K2HR & K3HR & Testing
- Check, Testing & perkuat support Proximity K1AR_PX, K2AR_PX & K3AR_PX
48 132-HT1001 Prev. Maintenance Boiler 1,2, 3 1
-Bersihkan panel ( dengan vacuum cleaner )
-Test indicator Lamp
-Check lImit Switch
-Perkuat support Module display
49 132-HT1003 Prev. Maintenance Boiler 4,5,6, 1
-Bersihkan panel ( dengan vacuum cleaner )
-Test indicator Lamp
-Check lImit Switch
-Perkuat support Module
50 132-HT1003 Prev. Maintenance Boiler 7 & Panel Demin 1
-Bersihkan panel ( dengan vacuum cleaner )
-Test indicator Lamp
-Check lImit Switch
-Perkuat support Module display
51 121-CO1010 Preventive Maintenance Conveyor LBKP/NBKP 1
- Bersihkan Local Panel, Perkuat wiring Cable Control di VS Drive Dan di Local Panel
- Check dan Test Push Button, Selector Switch, Tombol Emergency, indicator Lamp & Alarm
- Ganti Plastik Pelindung
52 121-CO3010 Preventive Maintenance Conveyor CTMP 1
- Bersihkan Local Panel, Perkuat wiring Cable Control di VS Drive Dan di Local Panel
- Check dan Test Push Button, Selector Switch, Tombol Emergency, indicator Lamp & Alarm
- Ganti Plastik Pelindung
- Check, Bersihkan Photo Cell Bale Counter
53 121-CO2010/1 Preventive Maintenance Conveyor Ledger 1
- Bersihkan Local Panel, Perkuat wiring Cable Control di VS Drive Dan di Local Panel
- Check dan Test Push Button, Selector Switch, Tombol Emergency, indicator Lamp & Alarm
- Ganti Plastik Pelindung
54 121-CO4010 Preventive Maintenance Conveyor OCC (selatan & utara ) 1
- Bersihkan Local Panel, Perkuat wiring Cable Control di VS Drive Dan di Local Panel
- Check dan Test Push Button, Selector Switch, Tombol Emergency, indicator Lamp & Alarm
- Ganti Plastik Pelindung
55 122-WE-PLC Preventive Maintenance Panel Control Wed End Kitchen & Komputer operator Station 1
-Cleaning Filter Fan, Cleaning Panel,Rapikan Wiring
-Bersihkan Komputer
56 122-WE-PLC Preventive Maintenance Device Area Kitchen Wet end 1
-Check dan Test Limit switch Manual Valve ( sesuai Checklist )
-Check dan Test Selector Switch Cleaning
-Check dan Test Push button
-Check dan Test Indicator Lamp
-Check dan Test alarm Lamp
-Bersihkan Local box dan Ganti plastik pelindung
-Lengkapi label device
57 120- Preventive Maintenance Aiphone Area BM 1
- Check dan test Aiphone
- Test Lampu Alarm Aiphone
- Rapikan kabel
58 120-GT2317 Preventive Maintenance Sheet break detector 1
- Cleanning dan alignment sensor
-Test Sheet break detector (sesuai checklist)

SHIFT-3
59 120-AJ3002 Preventive Maintenance Scanner 1st Coater & 2nd Coater 1
- Cleaning Beam dan Sensor Head
- Cleaning filter water cooling PMP
- Cleaning filter water cooling Scanner
- Check wire slider, ukur nilai resistensi grounding, Check Roller, Dll
- Cleaning photo cell scanner off sheet
- Beri pelindung plastik
60 123-FR1000 Preventive Maintenance Mesin Rewinder ( sesuai checklist ) 1
- Bersihkan Benchboard, fan & filter
- Check dan test device PX,LS & Photo cell
- Check Counter Length Autonic
- Ganti Plastik Panel View
61 123-FR1500 Preventive Maintenance Mesin Lowerator ( sesuai checklist ) 1
- Cleaning device, Check dan Test Device, Serta Perkuat baut support
- Lengkapi label device
62 120-WMS Preventive Maintenance Camera WMS 1
- Cleaning Lensa Camera
- Ganti plastik pelindung
- Check Connector camera
63 123-FR1100 Preventive Maintenance Mesin Bale press#01 1
-Cleanning device
-Check dan test LS Front & LS Back
-Cleanning panel + beri plastik pelindung
64 123-FR3250 Preventive Maintenance Mesin Roll Stretching # 02 ( utara ) Sesuai Checklist 1
- Cleanning device, Check dan Test Device
- Cleaning Panel Dan Cooling Fan
65 123-CT6240 Preventive Maintenance Core Cutter#2 1
- Bersihkan Panel, Ganti Plastik Pelindung Panel
- Check Lampu Indikator & Device
- Bersihkan Magnetic Tape
66 120-AJ3035 Preventive Maintenance Panel-Panel Automax DC Drive Drop A 1
- Bersihkan panel ( dengan vacuum cleaner )
- Bersihkan fan, bersihkan flow switch
- Check all fuse
67 120-AJ3035 Preventive Maintenance Panel-Panel Automax DC Drive Drop B 1
- Bersihkan panel ( dengan vacuum cleaner )
- Bersihkan fan, bersihkan flow switch
- Check all fuse
68 120-AJ3035 Preventive Maintenance Panel-Panel Automax DC Drive Drop C 1
- Bersihkan panel ( dengan vacuum cleaner )
- Bersihkan fan, bersihkan flow switch
- Check all fuse
69 120-AJ3035 Preventive Maintenance Panel-Panel Automax DC Drive Drop C ( Panel Fan Pump ) 1
- Bersihkan panel ( dengan vacuum cleaner )
- Bersihkan fan & Check Fuse
70 123-FR2200 Preventive Maintenance Ball Press #02 1
- Bersihkan Panel, Ganti Plastik Pelindung Panel
- Check Dan Test Limit Switch Head, Photo Cell & PX Ball Counter
- Check Lampu Indikator & Lampu Alarm
71 123-FR2500 Preventive Maintenance Ball Press #03 1
- Bersihkan Panel, Ganti Plastik Pelindung Panel
- Check Dan Test Limit Switch Head, Photo Cell & PX
72 123-FR6000 Preventive Maintenance Pallet Wrapping 1
- Bersihkan Panel, Ganti Plastik Pelindung Panel
- Check, Bersihkan PX Sensor, Photo Detector & Limit Switch
- Check, dan Test Lampu Indikator
- Perkuat Support Photo Detector
73 123-FR3100 Preventive Maintenance Ream Wrapping#02 & 03 1
- Bersihkan Panel, Ganti Plastik Pelindung Panel
- Check, Bersihkan Photo Detector & Limit Switch
- Check, dan Test Lampu Indikator
74 123-CT6240 Preventive Maintenance Core Cutter#2 1
- Bersihkan Panel, Ganti Plastik Pelindung Panel
- Check Lampu Indikator & Device
- Bersihkan Magnetic Tape
75 123-FR5000 Preventive Maintenance Ream Guillotine #01 & 02 1
- Bersihkan Panel
- Bersihkan Touch Screen
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
76 123-FR2400 Preventive Maintenance Mesin Salvage Winder 02 1
- Bersihkan Panel
- Bersihkan Touch Screen & ganti plastik pelindung
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
77 123-FR2600 Preventive Maintenance Mesin Salvage Winder 03 1
- Bersihkan Panel
- Bersihkan Touch Screen & ganti plastik pelindung
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
78 123-FR2800 Preventive Maintenance Mesin Salvage Winder 04 1
- Bersihkan Panel
- Bersihkan Touch Screen & ganti plastik pelindung
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
79 123-FR2800 Preventive Maintenance Mesin Salvage Winder 05 1
- Bersihkan Panel
- Bersihkan Touch Screen & ganti plastik pelindung
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
80 123-FR4000 Preventive Maintenance Mesin Sheeter #01 1
- Bersihkan Panel & Filter fan
- Lengkapi label device
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
81 123-FR4000 Preventive Maintenance Mesin Sheeter #02 1
- Bersihkan Panel & Filter fan
- Lengkapi label device
- Bersihkan Sensor-Sensor ( PX, Limit Swicth Dan Lain-lain )
KEGIATAN SEKSI
BAGIAN TEKNIK
RENCANA

Rencana
Seksi Pelaksana
Ref. Pekerjaan Lokasi MP T MP x T
& yg terkait Tanggal
(org) (mnt) (mnt)
10 11 13 14 15 16

( Hari ) 15
( Orang ) 15
( Menit ) 96180
( Jam / Hari ) 7.12

###
Prev. Maintenance BMB PC,Mek.Prev. H1/S1 2 90 180
Prev. Maintenance BMB PC H1/S1 2 90 180

Prev. Maintenance BMB PC H1/S1 3 180 540

Prev. Maintenance BMB PC H1/S1 5 240 1200

Spk No. 211/02/VI/23 BMB PC H2/S1 4 420 1680

- BMB PC H2/S1 2 420 840

Prev. Maintenance BMB PC H3/S1 5 420 2100

Prev. Maintenance BMB PC H4/S1 3 420 1260


Prev. Maintenance BMB PC H4/S1 5 420 2100

Prev. Maintenance BMB PC H5/S1 4 420 1680

Prev. Maintenance BMB PC H5/S1 4 420 1680

Prev. Maintenance BMB PC H6/S1 4 420 1680

Prev. Maintenance BMB PC H6/S1 4 420 1680

Prev. Maintenance BMB PC H7/S1 4 420 1680

Prev. Maintenance BMB PC H7/S1 3 420 1260

Spk No. 260/002/02/23 BMB PC H7/S1 4 420 1680

Prev. Maintenance BMB PC H8/S1 4 420 1680

Prev. Maintenance BMB PC H8/S1 3 420 1260

Prev. Maintenance BMB PC H8/S1 3 420 1260


Prev. Maintenance BMB PC H9/S1 4 420 1680

Prev. Maintenance CP PC H9/S1 4 420 1680


Prev. Maintenance CP PC H9/S1 4 420 1680

Prev. Maintenance SP PC H10/S1 5 420 2100

Prev. Maintenance SP PC H10/S1 4 420 1680

Prev. Maintenance SP PC H11/S1 5 420 2100

Prev. Maintenance SP PC H11/S1 4 420 1680

Prev. Maintenance SP PC H12/S1 4 420 1680

Prev. Maintenance SP PC H12/S1 4 420 1680

Prev. Maintenance BMB PC. H13/S1 4 180 720

Prev. Maintenance BMB PC. H13/S1 4 240 960

Preventive Maintenance BMB PC H13/S1 4 180 720


Prev. Maintenance BMB PC H13/S1 4 240 960

Prev. Maintenance BMB PC H14/S1 4 180 720

Prev. Maintenance BMB PC H14/S1 4 240 960

Prev. Maintenance BMB PC H14/S1 5 420 2100

Prev. Maintenance BMB PC H15/S1 4 420 1680

SPK No. CP PC H15/S1 4 420 1680

Prev. Maintenance CP PC H15/S1 3 420 1260

Prev. Maintenance BMB PC H1/S2 5 420 2100

Prev. Maintenance Fin PC H2/S2 5 420 2100

Prev. Maintenance BMB PC H3/S2 5 420 2100

Prev. Maintenance BMB PC H4/S2 4 180 720


Prev. Maintenance BMB PC H4/S2 4 240 960

Prev. Maintenance BMB PC H5/S2 4 420 1680

Prev. Maintenance BMB PC H6/S2 4 420 1680

Prev. Maintenance BMB PC H7/S2 4 420 1680

Prev. Maintenance BMB PC H8/S2 4 240 960

Prev. Maintenance BMB PC H8/S2 4 180 720

Preventive Maint. UTY PC H9/S2 4 420 1680

Preventive Maint. UTY PC H10/S2 4 420 1680

Preventive Maint. UTY PC H11/S2 4 420 1680

Prev. Maintenance SP PC H12/S2 4 240 960


Prev. Maintenance SP PC H12/S2 4 180 720

Prev. Maintenance SP PC H13/S2 4 240 960

Prev. Maintenance SP PC H13/S2 4 180 720

Prev. Maintenance CP PC H14/S2 4 120 480

Prev. Maintenance CP PC H14/S2 4 300 1200

Prev. Maintenance CP PC H15/S2 4 240 960

Prev. Maintenance BMB PC H15/S2 4 180 720

Prev. Maintenance BMB PC H1/S3 5 420 2100

Prev. Maintenance Fin PC H2/S3 6 420 2520


Prev. Maintenance Fin PC H3/S3 4 180 720

Prev. Maintenance BMB PC H3/S3 4 120 480

Prev. Maintenance Fin PC H3/S3 4 120 480

Prev. Maintenance Fin PC H4/S3 2 240 480

Prev. Maintenance FIN PC H4/S3 2 180 360

Prev. Maintenance BMB PC H5/S3 2 420 840

Prev. Maintenance BMB PC H6/S3 2 420 840

Prev. Maintenance BMB PC H7/S3 2 420 840

Prev. Maintenance BMB PC H8/S3 2 180 360

Prev. Maintenance FIN PC H8/S3 2 240 480

Prev. Maintenance FIN PC H9S3 2 180 360

Prev. Maintenance FIN PC H9S3 2 240 480


Prev. Maintenance FIN PC H10/S3 2 240 480

Prev. Maintenance FIN PC H10/S3 2 180 360

Prev. Maintenance FIN PC H11/S3 2 180 360

Prev. Maintenance FIN PC H11/S3 2 240 480

Prev. Maintenance FIN PC H12/S3 2 180 360

Prev. Maintenance FIN PC H12/S3 2 240 480

Prev. Maintenance FIN PC H13/S3 2 420 840

Prev. Maintenance FIN PC H14/S3 2 420 840

Prev. Maintenance FIN PC H15/S3 2 420 840

Kediri, 04. 07. 2023