MCO9(S) / KX200
Max. Max.
Product MC
Liner CSS feed size feed size Capacity
Size max. CSS
MCO9(S) MC

Standard Coarse
0-63 mm 35-42 mm < 200 mm < 110 mm < 700 mm 195-245 t/h

0-56 mm 32-38 mm < 190 mm < 105 mm < 650 mm 185-230 t/h

0-45 mm 28-32 mm < 185 mm < 100 mm < 600 mm 170-210 t/h

Standard Medium
0-45 mm 28-32 mm < 150 mm < 90 mm < 500 mm 170-210 t/h

0-32 mm 19-25 mm < 145 mm < 85 mm < 450 mm 150-190 t/h

Standard Fine
0-45 mm 28-32 mm < 130 mm < 80 mm < 400 mm 170-210 t/h

0-32 mm 19-25 mm < 125 mm < 80 mm < 400 mm 150-190 t/h

0-25 mm 16-20 mm < 120 mm < 80 mm < 400 mm 145-180 t/h

Shorthead Coarse
0-25 mm 16-20 mm < 140 mm < 85 mm < 450 mm 145-180 t/h

0-22 mm 13-19 mm < 125 mm < 80 mm < 400 mm 140-175 t/h

0-16 mm 13 mm < 80 mm - 110-140 t/h

Shorthead Medium
0-22 mm 13-19 mm < 110 mm - 140-175 t/h

0-16 mm 10-13 mm < 105 mm - 110-140 t/h

Shorthead Fine
0-16 mm 10-16 mm < 75 mm - 110-140 t/h

0-10 mm 6-10 mm < 50 mm - 80-100 t/h

All values are indicative only; Real results may vary depending on rock characteristics and boundary conditions
Max. feed sizes are based on spherical particles
Feed size is limited by the max. feed size of the liner and the max. reduction ratio of 4:1
Performance data are based on a feed material as Granite with a work index of 16 kWh/t and a reduction rate F80/P80 = 4:1
Kleemann will not guarantee any performances and particle size distribution of product prior to rock test in Kleemann laboratory

Liner Selection - Closed Circuits_v01-02.xlsx Christian Wilke 23.01.2017 1 /1

You might also like