Tissue Flotation Water Bath & Slider Dryer

BTH-I
User Manual
(Please read this manual carefully before use the device and keep it properly)

BIOBASE GROUP

Version 2021.09
Preface
Dear respected users:
Welcome to buy BIOBASE Tissue Flotation Water Bath & Slider Dryer (herein referred to as
Flotation Water Bath & Slider Dryer) , here please accept our sincere thanks!
We sincerely hope that our products will bring the greatest help for your work.
In order to make you have a better understanding of the product, please be sure to carefully read the
manual before use. The content of this manual is very important for you to use this machine safely
and correctly!
After you have read the manual carefully, please keep it in a convenient place for reference in the
future.
Information is subject to change without notice.
The company reserves the right to improve the performance of the device at any time without notice.

1
Content
Preface.................................................................................................................................................... 1
Content................................................................................................................................................... 2
1. Product Overview...............................................................................................................................3
2. Product Applicable Scope.................................................................................................................. 3
3. Product Performance.......................................................................................................................... 3
4. Product Receiving & Installation....................................................................................................... 4
4.1 Product Receiving..................................................................................................................... 4
4.2 Packing list................................................................................................................................ 4
Table 2 Packing List........................................................................................................................4
4.3 Product Installation....................................................................................................................4
5. Structure Composition........................................................................................................................5
6. Introduction for Use........................................................................................................................... 6
6.1 Operation panel......................................................................................................................... 6
Figure 2 Operation panel schematic diagram..................................................................................6
6.2 Operation method...................................................................................................................... 6
7. Precautions......................................................................................................................................... 7
8. Contraindication................................................................................................................................. 7
9. Cleaning & Maintenance....................................................................................................................8
10. Troubleshooting & Simple Parts Replacement................................................................................ 8
10.1 Fault diagnosis & troubleshooting.......................................................................................... 8
10.2 Simple parts replacement........................................................................................................ 9
11. Labels Description..........................................................................................................................10
12. Wiring Diagram..............................................................................................................................11
13. After-sales Service......................................................................................................................... 11

2
1. Product Overview
Tissue Flotation Water Bath & Slider Dryer (herein referred to as Flotation Water Bath & Slider
Dryer) is a device for bleaching tissue sections of human body or animal and plant specimens and
drying tissues after bleaching for subsequent histological diagnosis or research. It is widely used in
the Pathology Department.
BTH-I Flotation Water Bath & Slider Dryer is a kind of biological tissue device with embedded
system, which is in line with ergonomic design. It is specially used in the laboratory by professionals
who are familiar with tissue embedded technology and laboratory equipment and have received
appropriate training.

2. Product Applicable Scope


It is used to bath the tissue embedded wax blocks of human or animal and plant specimens before
pathological analysis as well as dry the glass slide attached with the wax piece.

3. Product Performance
The technical parameters of the product are as follows:
Table 1 Basis Performance Parameters
Model BTH-Ⅰ Flotation Water Bath & Slider
Parameters Dryer
AC(220±10%)V
Rated voltage
AC(110±10%)V
(50 ±10%)HZ
Rated frequency
(60 ±10%)HZ
Temperature setting range Room temperature~90℃
Temperature control range ±2℃
Over-temperature alarm range (1~5)℃
Outer size 695mm×400mm×210mm
Bathing box size 435mm×210mm×52mm
Drying table size 345mm×260mm
Power ≤600 W
Net weight 20kg

3
4. Product Receiving & Installation
4.1 Product Receiving
·When you receive the device, please confirm whether the specification and model of the device are
consistent with those you ordered.
·Please check whether the packing box of the device is damaged. If so, please do not unpack it at will,
but contact our company in time.
·Please check the items in the packing box according to the packing list, and check whether the
accompanying items and supporting documents are complete.

Note: In the process of receiving products, if you find any problems related to products,
please contact our company in time, and our company will deal with them in time.

4.2 Packing list


Table 2 Packing List
Name Qty
BTH-Ⅰ Flotation Water Bath & Slider Dryer 1set
RVV power cord 1pc
Fuse(5A) 1pc
User Manual 1copy
Certificate Card 1pc
Warranty Card 1pc

4.3 Product Installation


a. Requirements for installation environment:
(1) Only applicable to indoor;
(2) Ambient temperature: 15℃~35℃;
(3) Relative humidity: ≤75%;
(4) Atmospheric pressure range: 75 kPa~106 kPa;
b. Before connecting the AC power supply, ensure that the voltage of the power supply is consistent
with the input voltage of the spreader and the voltage is stable, and ensure that the rated load of the
power socket is not less than this requirement. Besides, the power supply must be reliably grounded.
c. When placing the device, it shall ensure that there is at least 100mm gap at the rear. Besides, it
must have good ventilation and heat dissipation environment.
d. The worktable must be flat. See the technical parameters for the weight of the device.

4
5. Structure Composition
BTH-I Flotation Water Bath & Slider Dryer is mainly composed of control system and heating
system. The specific structure is as follows:

1 4

1.Display screen 2.Power switch 3.bathing box 4. Drying table 5.Main power
supply connection port
Figure 1 Product structure diagram
The function of each part is as follows:
1. Display screen: used to set and display the working state of heating components;
2. Power switch: control the instrument current on-off;
3. bathing box: with heating function and the temperature range is (room temperature ~ 90 ℃), it is
not only the platform for water bath of the embedding wax block, but also the main operation
platform in the bathing process;
4..Drying table: with heating function and the temperature range is (room temperature ~ 90 ℃), it is
not only the platform for placing slices, but also the main operation platform in the process of drying;
5. Main power supply connection port: it is connected to the power cord through the power cord to
supply power to the equipment.

5
6. Introduction for Use
6.1 Operation panel

2 3 4 5

Figure 2 Operation panel schematic diagram


1.Display screen 2. Power button 3. Setting button 4. Temperature rise button 5. Temperature
drop button
Display screen: Display the working status of the working interface.
Power button: Used to control the working state of the device as well as the opening and closing of
the screen.
Setting button: Used to switch between the main interface and the setting interface.
Temperature rise button: Increase the displayed value.
Temperature drop button: Decrease the displayed value.

6.2 Operation method

Note: In case of emergency, please unplug the power plug directly.


(1) Preparation: Add distilled water into the bath to an appropriate position (25mm above the box
bottom and 10mm below the box top)

Note:Only distilled water can be used for heating. If other solvents are used due to actual
needs, it may rot the bath. In case of corrosion on the surface of the bath, please replace a new
one immediately.Do not use organic solvents or corrosive solvents.
(2)Startup and operation: connect the power socket and press the power button. At this time, the
equipment is in working state and starts heating. The display screen shows the set temperatures of
the bath and the dryer, respectively.
( 3 ) Preset temperature: press the setting button to enter the setting interface. The displayed
temperature is the set temperature. Press the temperature rise and temperature drop buttons to reach
the required set temperature, and the temperature will be automatically stored in the computer chip.
Press the setting button again to return to the main interface. If the user uses the last set temperature,

6
then this step can be skipped directly.
(4) Work

Note: Be careful, the temperature at the instrument surface may be very high.
Bath: Once the device is started, the bath box shall start to heat, when the preset temperature is
reached, the bath operation can be conducted

Note: Be careful, the temperature at the instrument surface may be very high.
The optimum water temperature is to change the 5 micron thick paraffin section from white to
transparent.
Dryer: Once the device is started, the drying table shall start to heat, when the preset temperature is
reached, the dryer operation can be conducted
If only one function is used, adjust the other temperature to room temperature.
( 5 ) Alarm setting: After turning off the power button, long press the setting button to enter the
alarm setting interface. Adjust the alarm value through the temperature rise and temperature drop
buttons. When the temperature reaches "set value + alarm value", the device will alarm, and long
press the setting button to save the alarm value.

Note: When the device gives an alarm, the user can directly press the temperature drop
button to silence.
(6) Replace the liquid in the bath: replace the liquid in the bath regularly. If the fixing liquid
containing mercury is used, the liquid in the bath shall be replaced every day, and the surface of the
bath shall be checked to see whether there is corrosion. If it is corroded, replace the bath
immediately.

7. Precautions
1. Do not use the product in the presence of flammable chemicals, otherwise it may cause fire or
explosion hazard.
2. During working, the bath and the dryer is very hot, which may cause serious burns.
3. When handling multiple samples at a time, please ensure that appropriate measures are taken to
avoid cross contamination caused by mixing.
4. When handling hazardous materials, ensure that appropriate measures are taken.
5. It is recommended to clean the device every day.
6. Please check the working temperature of the bath and dryer regularly with a standard thermometer
as well as compare the error between the measured value and the displayed value, and the average
value of the two readings shall be within ± 1 ℃. If this range has been exceeded for a long time,
please contact our company in time.

8. Contraindication
No.

7
9. Cleaning & Maintenance

Note: the following cleaning and maintenance work must be carried out when the power
supply is disconnected.
Do not use metal tools or reagents to clean the instrument surface.
1. Daily cleaning
·The following cleaning work shall be carried out after the equipment is used:
·Use a soft brush to remove the foam accumulated on the surface of the instrument or the
surrounding of the bath , especially the foam on the area where work is done
2. Weekly cleaning
·The following cleaning work shall be carried out once a week:
·Clean the display screen and buttons.
·Clean the body of the device
3.Maintenance
In order to ensure the equipment is in its best state, it is strongly recommended that the after-sales
service personnel approved by our company carry out maintenance once a year.

10. Troubleshooting & Simple Parts Replacement


10.1 Fault diagnosis & troubleshooting
Table 3 Fault diagnosis & troubleshooting
Fault Possible reasons Solutions
Check whether the power
The equipment has not been socket is charged and whether
connected to power supply the power cord is firmly
The display screen cannot plugged in.
display normally Check whether the power
switch is turned on
The connecting cable for the Unplug the cable and
power board and the display reconnect it
board is loose
The display screen is broken Replace a new display screen
The heating element cannot Temperature is set incorrectly Refer to the user interface to
heat reset the temperature
The heating element is burnt Contact our after-sales service
out personnel for replacement

8
10.2 Simple parts replacement
(1) Fuse replacement
First make sure the power switch is off.

Figure 3 Power cord connector


Finally, replace a new fuse (see the packing list for the parameters of the fuse ).

Figure4 Fuse holder

9
11. Labels Description
1. Company logo

Figure 5 Company logo


2.Fuse label

Figure 6 5A fuse label


3.Grounding label

Figure 7 Grounding label

10
12. Wiring Diagram

Figure 8 Wiring diagram

13. After-sales Service


 Warranty is 12 months from EX-factory date (excluding fuse).
 We will take no responsibility for risks caused by improper operation and man-made damages.
 After the expiration of warranty, our company is also responsible for repairs, but the
corresponding maintenance cost should be charged.
 Life time of the equipment is 5 years from production date on the label.
 We can provide equipment drawings and necessary technical data for maintenance companies or
personnel trained by our company.

11
BIOBASE GROUP
2# building, No.9 Gangxing Road, High-tech Zone, Jinan City, Shandong Province,
China
Tel: +86-531-81219803/01
Fax: +86-531-81219804
Inquiry: [email protected]
Complaints: [email protected]
After-sales service: [email protected]; [email protected]
Web: www.biobase.cc/www.meihuatrade.com / www.biobase.com

You might also like