ABOUT US facilities
1. The ADMISSIONS ACADEMICS
allocated to VU/ building shallSTUDENTS CAMPUSESand willRESEARCH
be exclusively dedicated & DEVELOPMENT
not be used SERVICES
for any other purpose. JOBS AND TENDERS VUTV IMPORTANT LINKS
2. The institution/ building should be located in an easily accessible area.
3. The location, building and outlook should be well suited for the purpose of higher education.
4. Properly finished and maintained exterior and interiors.
5. Parking facilities should be available in the vicinity.
Specific (Minimum Requirements)
1. . Covered area of at least 2000 Sq. ft. of usable space, excluding staircases, washrooms, lobbies, parking space etc.
2. Air-conditioned computer lab(s)
3. Dedicated Server room(s)
4. Adequate space for generator and UPS
5. Dedicated lecture viewing area
6. Student discussion room(s) with adequate furniture & white board
7. Common room(s) / waiting room(s) for female students
8. Separate washrooms for male and female students
Sr.# Item Specications Requirements
1 Computer Lab(s) Preferably big hall(s) instead of small rooms. Well ventilated and Air Conditioned.
Minimum Specifications with At Least Windows 10 A certain Ratio between Number of
2 Desktop PC Specifications
Operating System
PCs and total enrolled student
Intel Corei3 (6th Generation) RAM=4GB DDR-4 (Preferably 8GB) HDD=320GB or strength must be maintained which
higher will be communicated from time to
time. Initially 30 computers lab is
OR required for qualifying for PVC of
Virtual University of Pakistan.
HDD=SSD 128GB or higher
Recommended Specifications
(For atleast 4-5 years road map)
Intel Corei5 (6th Generation) or higher RAM=8GB DDR-4 HDD=SSD 256GB or
higher for better performance.
3 Servers Specifications Minimum Specifications with Latest Windows
Server Operating System
Intel Corei5 (6th Generation)
RAM=8GB DDR-4 (Preferably 16GB)
HDD=500GB or higher Total Servers = 03
AND
1 Active Directory,
HDD=1 x 4TB for lecture server only.
DNS,
DHCP,
Recommended Specifications RRAS
(For atleast 4-5 years road map)
Intel Corei5 (6th Generation) or higher
RAM= 16GB DDR-4
HDD= 256GB SSD or higher for better performance.
2 Exam Server.
OR
HDD=1TB or higher.
AND
HDD=1 x 4TB for lecture server only. 3 Active Directory,
DNS,
DHCP,
RRAS
& Exam Server.
4 Display Minimum Specifications
LED\LCD (Widescreen) = 17” - 19” (Preferably 19”)
Recommended Specifications Or Higher
LED\LCD (Widescreen) = 23”
5 Internet Connection Minimum 8-MBs for every 30 computers. Preferably CIR / Dedicated. Reliable and fast internet connection.
6 Backup Internet Connection Same as Primary Same as Primary
7 Generators
20 kVA generator is recommended for every 30 Computers, 3 Servers, Network Must support all servers, client
Switches, 1 Printer, 1 Scanner, & CCTV Camera system alongwith building load. computers, other IT equipment, A/Cs,
building load, and remain in perfect
working condition at all times.
8 UPS
10 kVA UPS is recommended for every 30 Computers, 3 Servers, Network Must support all servers, client
Switches, 1 Printer, 1 Scanner, & CCTV Camera System. computers, other IT equipment, and
remain in perfect working condition
at all times.
9 Printer
One Laser printer Must remain in perfect working
condition at all times.
10 Scanner
With resolution of 1200 dpi, 48-bit color Must remain in perfect working
condition at all times.
11 Shields
Cover for all monitors All monitors must have shield covers.
12 CCTV Camera
NVR/IP based CCTV cameras must be installed at entrance and computer lab(s) with capacity to hold at least fifteen days
recording.
13 Network Infrastructure
Gigabit network must be installed with proper termination using keystone jack (I/O). Switches must be installed in
Network cabinet. Network cables must be terminated in network cabinet using patch panel and tagged properly. Cable
manager should be used for termination from Patch Panel to Network Switch. Network cables should be in ducts.
14 Anti-Virus
Mandatory Updated Antivirus on servers and all
client computers.
15 Air Conditioners
Air Conditioners must be installed to maintain comfortable temperature in all computers labs & server room and
supported by the generator.
16 Networking Staff
Qualication: BS (CS/IT) (OR) BE (EE) (at least 2nd division) from HEC recognized University / Institution. Experience &
Skills: Must be experienced in System/Network administration. Internationally acclaimed valid Network Certification will
be preferred.
In case PVC is nominated as Exam Center, one additional server will be required.