SURAJ INN-GAD-4-37-23-291 - Rev1 Signed
SURAJ INN-GAD-4-37-23-291 - Rev1 Signed
Motor Kw
4 Pole (TP+N) MCB (Class-C) with ELCB in
GENERAL CLIENT'S SCOPE site, upto Elevator Machine Room
(Cu_4 core, (TP+N), 415V, 50 Hz Armoured Cable) machine room, for power supply to
elevator controller
(Class-B) with ELCB
in machine room, for
Cross Section Area (mm²) Lighting Circuit
1. Strong scaffolding in elevator shaft at the time of installation as per guide lines by installation engineer.
2. Making of wooden template & all arrangement to fix the same as per installation engineer's guide lines. Length of Length of Length of Length of Length of Length of Earth-Leakage Rated Current Earth-Leakage
Rated Current (A)
cable 30m cable 45m cable 60m cable 90m cable 120m cable 150m Sensitivity (mA) (A) Sensitivity (mA)
3. Supply & fixing of wooden / steel door & door frame on each landing.
14.2 6 10 10 16 16 25 63 300 6 30
4. Cutting, making good holes, grouting / welding for fixing brackets, controller, speed governor, landing fixtures, machine beam , buffer sockle and grouting etc.
NOTE:-1) CONTROLLER SHOULD BE PLACED WITHIN 2 METER RADUIS FROM MACHINE.
5. Storage room of area 40 sq.m per elevator with weather protection and locking arrangement and provision of single phase light & power plug of 2) 2) TWO SEPERATE EARTH WIRES MIN. 8 SWG GI/COPPER WELDED FROM EARTHING PIT TO MACHINE ROOM TERMINATED ON EARTHING BUSBAR
15 Amp. capacity. Storage room must be within the radius of 10m from erection site. It must be kept ready before arrival of material at site OR GI/COPPER STRIP PROPERLY WELDED OR BRAZED AT JOINTS
& will remain in possession of installation engineer till the erection of elevator is completed and handed over to client.
6. Preparatory work - All openings of elevator well must be barricaded to avoid accidents & disturbances during pre & post erection.
7. 3 phase power supply with earthing require at the start of installation.
31. Elevator shaft dimensions mentioned in layout drawings are minimum clear plumb dimensions in mm, and hence the actual wall should not encroach TYPE OF CAR DOOR AUTO. C. O. DOOR RPM 158
on these dimensions.
STOPS / LANDINGS 14 / 14 SUSPENSION ROPES
32. The inside finished face of the hoist way should fall within the limits from clear plumb elevator shaft well dimensions as mentioned below,
CONTROL TRIPLEX COLLECTIVE SELECTIVE SIZE 6 NOS. Ø10
For lift well height upto 30 m = 0 to +25 mm
For lift well height upto 60 m = 0 to +35 mm DRIVE ACVVVF
For lift well height upto 90 m = 0 to +50 mm (As per IS:14665 (Part 2 / Sec 1) : 2000) SPEED 2.00 m/s
33. The Elevator shaft should be without any projection and recesses from machine room slab to the pit floor.
LOAD 1020 Kg.
34. If any projections or recesses are there, than those should be flushed and leveled on underside to an angle not less than 60° from the
PASS. CAPACITY 15
horizontal by means of metal plates or cement.
35. Service pipes, ventilation ducts, electrical conduits etc. for other purpose are not allowed to run in the elevator shaft and machine room. LAYOUT_CLIENT'S SCOPE SHEET _ 1 OF 6
All dimensions are in mm, scale 1:1, otherwise as specified.
36. Cutting and making pocket holes in lift well for grouting and fixing of car and C'wt. guide brackets or shaft reduction channels and angles if
elevator shaft walls are of brick.
37. All landing entrances of the elevator should be closed properly and protected by suitable material till elevator installation is completed.
38. Architrave fixing and finishing to be done after fixing of doors and door frames on all floors fill gap between door frame and entrance wall before architectrave work and 01 CHANGES: MACHINE ROOM, KEY PLAN FOR TRIPLEX Anil Yadav 30/03/2024
after installation of door frame.
39. Vent 0.2 SQ. MTR with suitable rain protected cover and wire net of SQ. mesh 25x25 wire Ø3mm, location of smoke window shown in GAD is only a representative
Internally Approved By Revision Details Revised By Date
PIT
This presentation is our Intellectual property.
Rev.
43. RCC socales for fixing car and C'wt. buffers. Checked by S.G. Bhaganagare 30/12/2023 Job No.- 4-37-23-291 01
44. RCC or Brick partition wall upto 2100 mm height to be provided if two lifts are in the common shaft. Approved by T.P. Humbad 30/12/2023
45. Pit floor and walls to be treated for waterproofing and to minimize accumulation and circulation of dust as per IS 14665 (Part 2 / Sec 1) : 2000.
46. Access to pit - All pits shall have permanent non-combustible vertical ladder installed for easy access to authorized personnel. TK Elevator India Private Limited
TK Elevator India Private Limited
Multi Purpose Facility: Plot No. A-23, MIDC Chakan , Phase II, Village - Khalunmbre, Taluka - Khed, District - Pune Maharashtra - 410 501.
Phone: +91-02135-624500 Fax: +91-02135-662301
F.CE.17:REV-01
A
500
GAP
GAP
95
"X"
150 139 GBS = 950 69
3145
2475
GB = 900
85 C'WT RAIL C'WT FRAME OUTSIDE 150
11 22
2475
2500
RCC
200
1040
SHAFT LIGHT
VDP=1110
10 21
*300 370
1798
2500
ISMC 250
Ø406
365
506
RCC SLAB
5000
ISMB300 20
200
2500
CL C'WT
200
758
Ø406 GUIDE
450
358
8
9 19
T 89 * 62 * 16
2500
203 CAR RAIL
75
.PMOC COMP.
TOP CLERANCE
5000
18 NIAHC CHAIN
2500
1600
1150
SW ASSEMBLY BINARY VANE &
FOR DETAILS, INDUCTION ASSEMBLY
17
950
2500
CAM ASSEMBLY
ST = 2480
KBS = 1570
KT = 1700
345
2500
1100
1000
Ø406
CL CAR
178
178
7 15
GUIDE
O.H.R.H = 5000
2500
153 153
2500
750
KB = 1450
855
885
2200 MIN. CLEAR LINTEL HIGHT
965
2400 CAR CLEAR HEIGHT
6 13
2100 CLEAR ENTRANCE
COP-1
COP-2
2500
AXIS
CAR
5000
12
105
2500
215
ELEVATOR ENTRANCE
80
11
BRICK
30
5
200
2500
T° FLOOR TRAVELLING LOP
5000
TOP MOST FLOOR 10 CABLE
550 900W * 2100H 550
2500
CLEAR ENTRANCE
1000 1000
505
4 9
2500
200 SB = 2000 200
RCC CLEAR SHAFT WIDTH RCC
5000
(11) - (T) 5975 8
A
OF CWT GUIDE
2500
(10) - (11) 3250
As a continuing policy of product improvement at ThyssenKrupp Elevator,
COMP.
3 7
CHAIN (8) - (9) 3250
2500
(7) - (8) 3250
CAR TRAVEL= 49050
CLIENTS APPROVAL
CL
2500
(5) - (6) 3250
(4) - (5) 3250
5 STEEL HOOK SIGNATURE & SEAL
(3) - (4) 3250 2
CAPACITY = 2500 KG
2500
(2) - (3) 3250 FOR DETAILS, REF. NOTE NO. 16
5000
1 3
FLOOR HEIGHT IN MM
2500
ELEVATOR ENTRANCE 01 CHANGES: MACHINE ROOM, KEY PLAN FOR TRIPLEX Anil Yadav 30/03/2024
100
Revision Details Revised By Date
5000
B° FLOOR 2
700(min.) 100 700(min.)
CL
C'WT ENCLOSURE
300
This presentation is our Intellectual property.
CAR BOTTOM RUN BY Site - DOUBLE TREE SUITES BY HILTON, IBLUR GATE,
150
10 mm thick CAR & C'WT CAR & C'WT Suraj Nair ORR - SARJAPUR ROAD JUNCTION, BENGALURU - 560 102.
RAIL SUPPORT PLATE GUIDE RAIL BRACKET Drawn by T.P. Humbad 30/12/2023
nor communicated to third party.
Rev.
STROKE
780
between JOINTS POSITIONS Checked by S.G. Bhaganagare 30/12/2023 Job No.- 4-37-23-291 01
275
780
1. PULLEY WITH RED COLOUR RIM – DIVERTER PULLEY TK Elevator India Private Limited
2. PULLEY WITH BLUE COLOUR RIM - SUSPENSION PULLEY
*100
* SOCLE HEIGHT OF CAR & CWT BUFFER TK Elevator India Private Limited
SECTION A-A PIT LADDER TO BE DECIDED DURING ERECTION Multi Purpose Facility: Plot No. A-23, MIDC Chakan , Phase II, Village - Khalunmbre, Taluka - Khed, District - Pune Maharashtra - 410 501.
Phone: +91-02135-624500 Fax: +91-02135-662301
F.CE.17:REV-01
365
365
'B'
CL C'WT CL C'WT
200
GUIDE GUIDE
'B'
'C' 203 203 'C' 250
P9
203
X = 947
835
1150
1150
ST = 2480
240
'D'
P7/2 250 P7/2
225
203
'B'
CL CAR CL CAR
200
GUIDE GUIDE
203
'C' 'C'
P8
965
965
AXIS
CAR
450 450
100
AXIS
CAR
'A' 'C' 'C' 'C'
'C' 100*100
Internally Approved By
LAYOUT_ELEVATOR PIT FLOOR & MACHINE ROOM POCKET DETAILS SHEET _ 3 OF 6
Suraj Nair
All dimensions are in mm, scale 1:1, otherwise as specified.
01 CHANGES: MACHINE ROOM, KEY PLAN FOR TRIPLEX Anil Yadav 30/03/2024
Revision Details Revised By Date
Rev.
Loads P8 / P9 in case either car or counterweight lands on the buffers. Checked by S.G. Bhaganagare 30/12/2023 Job No.- 4-37-23-291 01
Approved by T.P. Humbad 30/12/2023
P9 73245 N
P8 93260 N TK Elevator India Private Limited
P7 46630 N
TK Elevator India Private Limited
LOADS (N)_ Multi Purpose Facility: Plot No. A-23, MIDC Chakan , Phase II, Village - Khalunmbre, Taluka - Khed, District - Pune Maharashtra - 410 501.
Phone: +91-02135-624500 Fax: +91-02135-662301
F.CE.17:REV-01
9200
2880
W # CONTROLLER
1220 1206 453
593
445 705
CL C'WT
L = 501
GUIDE
190
4-37-54583(01)
4-37-23-291
217
SB = 2000
R2
CAR
433
AXIS
R1
216
"X"
1200
ISMB300
CL CAR
387
GUIDE
Ø485 462
ISMB300
190
203 X = 947
SPEED GOVERNOR
207
200 965 1150 365 200
4500
4500
2500
4-37-54584(02)
SHAFT SIZE : 2000 W X 2400 D
E
As a continuing policy of product improvement at ThyssenKrupp Elevator,
The design and specifications are subject to change without prior notice.
M/C ROOM
ENTRANCE
Suraj Nair
All dimensions are in mm, scale 1:1, otherwise as specified.
Rev.
E EXHAUST Checked by S.G. Bhaganagare 30/12/2023 Job No.- 4-37-23-291 01
Approved by T.P. Humbad 30/12/2023
F.CE.17:REV-01
'Z' LINTEL (FULL RCC) LINTEL (FULL RCC) LINTEL (FULL RCC)
LINTEL (FULL RCC)
FIREMAN SWITCH 200 GAP FOR FINISHING THE LEVEL,
ONLY ON MAIN FLOOR DW1 DW1 TO BE FILLED UP ONLY AFTER
INSTALLATION OF SHAFT DOORS
DW2 DW2
268
268
316
316
100
FINISHED ENTRANCE
HEIGHT OF OPENING
DH
FFL FFL FFL FFL
Ø80
140-170
185
135
'A' 'B' 'A' 'B'
DH1
Core Core MD
Detail View 'X'
390
ELEVATOR ENTRANCE
DH2
Below fixation scheme detail View ''X'', "Y" & ''Z'' should be as per supplied material by Factory
DH3
DH
140
1875
140-170
DW2 DW2
200 200
135
21
1100
DW4 DW4
SDW
SILL FIXING ARRANGEMENT HEADER FIXING ARRANGEMENT
FFL FFL
TYPE ENTRANCE (DOOR) HEIGHT
'DH' 2000 2100 2200 * 7 N: - - - 73 73 73
8 DW6: - - - 310 310 310
1 DH1: 650 683 716
135
50
1 DH1: 650 683 716 750 783
* Applicable for DW800 & DW900 only 2 DH2: (DH+268) 2268 2368 2468 2568 2668
200 200 3 DH3: (DH+80) 2080 2180 2280 2380 2480
'X' 4 D: 216 316 416 416 416
SDW
1000 1000
200 SW = 2000 200 LANDING SECTION VIEW
RCC CLEAR SHAFT WIDTH RCC
40
80
40
As a continuing policy of product improvement at ThyssenKrupp Elevator,
The design and specifications are subject to change without prior notice.
50 CLIENTS APPROVAL
LOP
900
SIGNATURE & SEAL
01 CHANGES: MACHINE ROOM, KEY PLAN FOR TRIPLEX Anil Yadav 30/03/2024
In the case the control cabinet is located in a fire sector different to other higher floors or Rev.
building areas (very exceptional situation because only in very particular exceptions the
Checked by S.G. Bhaganagare 30/12/2023 Job No.- 4-37-23-291 01
Approved by T.P. Humbad 30/12/2023
lift shaft communicates different fire sectors at different heights), the control cabinet
must be installed on the wall or with full front variant. TK Elevator India Private Limited
TK Elevator India Private Limited
Multi Purpose Facility: Plot No. A-23, MIDC Chakan , Phase II, Village - Khalunmbre, Taluka - Khed, District - Pune Maharashtra - 410 501.
Phone: +91-02135-624500 Fax: +91-02135-662301
F.CE.17:REV-01
#
SCAFFOLDING
500
SB = 2000
CLEAR SHAFT WIDTH
>Ø73.2mm L R
B
100
>Ø43.9-Ø50mm
975.5
100
F
FIG. 2 #
SHAFT PLAN
900
#
As a continuing policy of product improvement at ThyssenKrupp Elevator,
The design and specifications are subject to change without prior notice.
FIG. 3
500
FIG. 4
SHAFT ELEVATION B= F= L= R= 01 CHANGES: MACHINE ROOM, KEY PLAN FOR TRIPLEX Anil Yadav 30/03/2024
Revision Details Revised By Date
Note : 1. Ø Of bamboo not less than 75mm. OR Ø of m.s pipe not less than 50mm (If m.s scaffold is erected.) CLIENTS APPROVAL VITTAL MALLYA ROAD, BENGALURU - 560 001.
Without our written consent , it shall neither be
This presentation is our Intellectual property.
2. Scaffolding should be in plumb. Site - DOUBLE TREE SUITES BY HILTON, IBLUR GATE,
ORR - SARJAPUR ROAD JUNCTION, BENGALURU - 560 102.
3. Earthing connection is required in case of m.s scaffolding. SIGNATURE & SEAL Drawn by T.P. Humbad 30/12/2023
nor communicated to third party.
Rev.
4. Before erecting the scaffolding, Pit should be clean, waterproof. Checked by S.G. Bhaganagare 30/12/2023 Job No.- 4-37-23-291 01
5. If vertical member diameter is reduced to 45-50mm than there should be overlapping in vertical member as shown in fig. 4. Approved by T.P. Humbad 30/12/2023
F.CE.17:REV-01