PG SERIES
Fire & Telecomms Emergency Utility Solar Wind UPS
Security Lighting
FEATURES
PG-12V100 FR 12V 104.0 AH @ 20-hr.
12V 98.8 AH @ 10-hr.
• Absorbent Glass Mat (AGM) technology for superior
performance
Rechargeable Sealed Lead Acid Battery • Superb high-rate discharge characteristics ensures
PG – Long Life Series reliable performance in UPS and telecom applications
TERMINALS: (mm)
• Proven valve regulated technology that guarantees safe
operation without maintenance
T6: Threaded insert with
6mm stud fastener
16mm • Rugged impact resistant ABS case and cover, flame
M6 retardant to UL94:V-0
6mm
• Thick plate design and efficient gas recombination yield a
service life of 10 – 12 years in standby mode
APPROVALS
• Approved for transport by air. D.O.T., I.A.T.A., F.A.A.
and C.A.B. certified
Torque: 3.9~5.4 Nxm • U.L recognized
• ISO9001:2015 – Quality management systems
DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS
Nominal Voltage 12 volts (6 cells)
L: 12.05 (306)
W: 6.61 (168)
Nominal Capacity
H: 8.27 (210)
20-hr. (5.20A to 10.80 volts) 104.0 AH
W HT: 8.51 (216) 10-hr. (10.0A to 10.80 volts) 98.8 AH
Tolerances are +/- 0.04 in.
(+/- 1mm) and +/- 0.08 in.
5-hr. (17.4A to 10.50 volts) 87.0 AH
(+/- 2mm) for height 1-hr. (60.8A to 9.60 volts) 60.8 AH
dimensions. All data subject
to change without notice.
Approximate Weight 69.5 lbs. (31.5 kg)
Internal Resistance (approx.) 4.9 milliohms
Sealed Long Life
Rechargeable Battery Max Short-Duration Discharge Current (10 Sec.) 600 amperes
HT H
Shelf Life (% of nominal capacity at 68°F (20°C)
1 Month 97%
PG-12V100-FR
(UL94 V-O flame retardant)
12 Volt 104 A.H.
®
Pb
3 Month 91%
C
@ 20-hr. rate to 10.8V
NONSPILLABLE
MH 20845
100 A.H. @ 10-hr. rate to 10.8V Power-Sonic Corporation
www.power-sonic.com 6 Month 83%
L Operating Temperature Range
Charge 5°F (-15°C) to 122°F (50°C)
Discharge -4°F (-20°C) to 140°F (60°C)
CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED Case
Flame Retardant ABS Plastic
UL94:V-0
(USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA)
Power-Sonic Corporation 3 Buckingham Square,
Hurricane Way, Wickford, Power Sonic Chargers PSC-1220000-PC
7550 Panasonic Way, San Diego,
California 92154 Essex SS11 8YQ
T: +1 (619) 661 2020 T: +44 (0)1268 560686
F: +1 (619) 661 3650 F: +44 (0)1268 560902
E:
[email protected] E:
[email protected] Rev1: 11/18
To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective
All data subject to change without notice. E&O.E
www.power-sonic.com
owners.
PG SERIES
PG-12V100 FR 12V 104.0 AH @ 20-hr.
12V 100.0 AH @ 10-hr.
Rechargeable Sealed Lead Acid Battery
PS – General Purpose Series
FLOAT LIFE IN YEARS VS. TEMPERATURE GENERAL RELATION OF CAPACITY VS. STORAGE TIME
14.0 100
Capacity Retention Ratio (%)
Charging is not
12.0 necessary unless
100% of capacity
Float Life (Year)
is required.
10.0 80
5°C Charging before
8.0 use is necessary
(41°F) to help recover
full capacity.
6.0
60
4.0 Charge may fail
to restore full
2.0 40°C 30°C 20°C capacity. Do not
(104°F) (86°F) (68°F) let batteries
40 reach this state.
0
20 25 30 35 40 °C 45 °C 0
68 77 86 95 104 °F 113 °F 0 2 4 6 8 10 12 14 16 18 20
Battery Temperature Standing Period (months)
CHARGING CHARGERS
Cycle Applications: Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable
2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. for batteries with a variety of capacities.
Initial charging current should be set at less than 0.25C
Please refer to our website for more information on
Amps. Switch to float charge to avoid overcharging.
our switch mode and transformer type chargers.
“Float” or “Stand-By” Service: Apply constant voltage
charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Please contact our technical department for advice if
Monobloc at 20°C. When held at this voltage, the battery you have difficulty in locating a suitable charger.
will seek its own current level and maintain itself in a fully
charged condition. FURTHER INFORMATION
Temperature Compensation: Charging Voltage for both Please refer to our website www.power-sonic.com
Cyclic and Standby applications should be regulated in for a complete range of useful downloads, such as
relation to ambient temperature. As temperature rises product catalogs, material safety data sheets (MSDS),
charging voltage should be reduced to prevent overcharge ISO certification, etc.
and increased as temperature falls to avoid undercharge.
For further charging information including temperature
compensation factors, see Power Sonic Technical Manual/
Power Sonic Charger specifications.
APPLICATIONS
A whole range of CYCLIC applications • Utility
including but not limited to: • Solar
• Fire and Security • Emergency • Wind
• Telecommunications Lighting • UPS
CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED
(USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA)
Power-Sonic Corporation 3 Buckingham Square,
7550 Panasonic Way, San Diego, Hurricane Way, Wickford,
California 92154 Essex SS11 8YQ
T: +1 (619) 661 2020 T: +44 (0)1268 560686
F: +1 (619) 661 3650 F: +44 (0)1268 560902
E:
[email protected] E:
[email protected] Rev1: 11/18
To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
All data subject to change without notice. E&O.E www.power-sonic.com