PS SERIES
General Emergency Medical Fire &
Purpose Lighting Security
PS-12280
FEATURES
12V 28.0 AH @ 20-hr. • Absorbent Glass Mat (AGM) technology for
12V 26.0 AH @ 10-hr. superior performance
Rechargeable Sealed Lead Acid Battery • Valve regulated, maintenance free spill proof construction
PS – General Purpose Series
• Power/volume ratio yielding excellent energy density
TERMINALS: (mm) • Rugged vibration and impact resistant ABS case
and cover
NB1: Tin plated brass post with
‘Nut & Bolt’ fasteners • Gas recombination technology
• 5 year design life
12mm 2mm
APPROVALS
4.8mm
6mm
12mm
• Approved for transport by air. D.O.T., I.A.T.A., F.A.A.
and C.A.B. certified
• U.L. recognized
Torque: 2.0~3.0 Nxm
• ISO9001:2015 – Quality management systems
DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS
L: 6.50 (165) Nominal Voltage 12 volts (6 cells)
W: 4.92 (125)
H: 6.89 (175) Nominal Capacity
HT: 6.89 (175) 20-hr. (1.40A to 10.80 volts) 28.0 AH
W Tolerances are +/- 0.04 in.
(+/- 1mm) and +/- 0.08 in.
10-hr. (2.60A to 10.80 volts) 26.0AH
(+/- 2mm) for height
5-hr. (4.76A to 10.50 volts) 23.8 AH
dimensions. All data subject 1-hr. (17.6A to 9.60 volts) 17.6 AH
to change without notice.
Approximate Weight 20.95 lbs. (9.5 kg)
Internal Resistance (approx.) 14.0 milliohms
Max Short-Duration Discharge Current (5 Sec.) 420.0 amperes
Sealed Rechargeable
Battery
HT H Shelf Life (% of nominal capacity at 68°F (20°C)
MODEL PS-12280 NB
12 Volt 28.0 Amp. Hr.
1 Month 97%
® MU
ST B E R
3 Month 91%
EC
TTE RY
Pb
YC L E D
6 Month 83%
MH20845
BA
www.power-sonic.com NONSPILLABLE
Operating Temperature Range
L Charge 32°F (0°C) to 104°F (40°C)
Discharge 5°F (-15°C) to 122°F (50°C)
Case ABS Plastic
GLOBAL HEADQUARTERS
L: 6.50 (165) POWER-SONIC
W: 4.92 (125) H: 6.97 (177) HT:EMEA
6.97 (177)
(USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA)
Power-Sonic Corporation Smitspol 4, 3861 RS Nijkerk, PSC-124000-PC
Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for Power Sonic Chargers
365 Cabela Dr Suite 300, The Netherlands PSC-124000A-C
Reno, height
Nevada dimensions.
89523 All data subject
T NL: to change
+ 31 33 7410without
700 notice.
USA T UK: + 44 1268 560 686
T: +1 619 661 2020 T FR: + 33 344 32 18 17
E:
[email protected] E:
[email protected] Rev2: 08/20
To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
All data subject to change without notice. E&O.E www.power-sonic.com
PS SERIES
PS-12280 12V 28.0 AH @ 20-hr.
12V 26.0 AH @ 10-hr.
Rechargeable Sealed Lead Acid Battery
PS – General Purpose Series
SHELF LIFE & STORAGE
100 SHELF LIFE & STORAGE
SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY IN
LIFE CHARACTERISTICS USESTAND-BY USE
Charging is not
LIFEAmbient
CHARACTERISTICS IN STAND-BY USE
necessary unless
Capacity Retention Ratio (%)
100 100% of capacity
is required. Charging is not Temperature 20˚C (68˚F)
Percentage of capacity
necessary unless 100
Capacity Retention Ratio (%)
80
5oC Charging before 100% of capacity
Ambient Temperature 20˚C (68˚F)
available (Ah%)
use is necessary is required.
Percentage of capacity
80 (41oF) to help recover 80 100
5fulloCcapacity. Charging before
available (Ah%)
60 use is necessary 60
(41oF) to help recover 80
full capacity. Float Charging Voltage
60 o 40 60
30 C 2.25 - 2.30 V/Cell
o
40 C 20 C o
o
40 (104oF) (86 F) (68oF) Float Charging Voltage
o 20 40
40oC 30 C
o
20oC 2.25 - 2.30 V/Cell
0 40 (104oF) (86 F) (68oF) 0 20
0 2 4 6 8 10 12 14 16 18 20 0 1 2 3 4 5
0 0 Years
Standing
0 2 4Period
6 (Months)
8 10 12 14 16 18 20 0 1 2 3 4 5
Standing Period (Months) Years
CHARGING CHARGERS
Cycle Applications: Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable
2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. for batteries with a variety of capacities.
Initial charging current should be set at less than 0.25C
Please refer to our website for more information on
Amps. Switch to float charge to avoid overcharging.
our switch mode and transformer type chargers.
“Float” or “Stand-By” Service: Apply constant voltage
Please contact our technical department for advice if
charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v
you have difficulty in locating a suitable charger.
Monobloc at 20°C. When held at this voltage, the battery
will seek its own current level and maintain itself in a fully
charged condition. FURTHER INFORMATION
Temperature Compensation: Charging Voltage for both Please refer to our website www.power-sonic.com
Cyclic and Standby applications should be regulated in for a complete range of useful downloads, such as
relation to ambient temperature. As temperature rises product catalogs, material safety data sheets (MSDS),
charging voltage should be reduced to prevent overcharge ISO certification, etc.
and increased as temperature falls to avoid undercharge.
For further charging information including temperature
compensation factors, see Power Sonic Technical Manual/
Power Sonic Charger specifications.
APPLICATIONS
• General purpose • Medical
• Emergency lighting • Fire and security
GLOBAL HEADQUARTERS POWER-SONIC EMEA
(USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA)
Power-Sonic Corporation Smitspol 4, 3861 RS Nijkerk,
365 Cabela Dr Suite 300, The Netherlands
Reno, Nevada 89523 T NL: + 31 33 7410 700
USA T UK: + 44 1268 560 686
T: +1 619 661 2020 T FR: + 33 344 32 18 17
E:
[email protected] E:
[email protected] Rev2: 08/20
To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
All data subject to change without notice. E&O.E www.power-sonic.com