TECHNICAL DATA DSA4-22
DENO tag nr:
Manufacturer: Deno Compressors
Type: DSA4
DSA5,5 & DSA7,5
DSA11 & DSA15
DSA18,5 & DSA22
Project:
Contact:
van der Giessenweg 49
2921 LP Krimpen a/d IJssel
The Netherlands
Tel : +31 180 442 288
Fax : +31 180 522 222
@ :
[email protected] www.denocomp.nl
Read this manual carefully before installation, operation or maintenance.
Pay close attention to ensure your safety when working on the machine.
Make sure that the dryer is completely depressurised and the power supply is
securely cut off before attending any adjusting or checking.
LIST OF CONTENTS
1. Technical data ................................................................................... 2
1.1. DSA4 compressor ........................................................................................................ 2
1.2. DSA5,5 and DSA7,5 compressors ............................................................................... 3
1.3. DSA11 and DSA15 compressors ................................................................................. 4
1.4. DSA18,5 and DSA22 compressors .............................................................................. 5
2. Components and views ....................................................................... 6
3. Screw assembly views ......................................................................... 9
4. Power supply system requirement..................................................... 10
1/10
1. Technical data
1.1. DSA4 compressor
Compressor type DSA4
Forced overpressure MPa 1,0
m3/h 28
Capacity*
m3/min 0,46
Weight kg 250
Overall dimensions
mm 790x810x1110
(L x W x H)
Tank capacity l -
Compressed air
G1/2
connection
Compressed air
mm 730
connection height
0
Ambient temperature C from 5 to 45
Compressed air 0
C around 15°C above ambient temperature
temperature
Noise level L**) dB(A) 70
0
Max. oil temperature C 110
Motor power output kW 4,6
Supply voltage V 460 (60Hz)
Cooling air requirement m3/h 800
*) - capacity measured acc. to ISO 1217 Appendix C, 1996
**) - momentary value of acoustic pressure corrected by C characteristic does not exceed 130 dB;
- equivalent acoustic pressure level corrected by A characteristic does not exceed 85 dB(A).
2/10
1.2. DSA5,5 and DSA7,5 compressors
Compressor type DSA5,5 DSA7,5
Forced overpressure MPa 0.8 1.0 1.3 1.5 0.8 1.0 1.3 1.5
m3/h 50 40 33 20 68 57 47 35
Capacity*
m3/min 0.83 0.66 0.55 0.33 1.13 0.95 0.78 0.58
Weight kg 280 290
Overall dimensions
mm 790x810x1110 790x810x1110
(L x W x H)
Tank capacity l - -
Compressed air
G1/2 G1/2
connection
Compressed air
mm 799 799
connection height
0
Ambient temperature C from 5 to 40
Compressed air 0
C around 10°C above ambient temperature
temperature
Noise level L**) dB(A) 70 70
0
Max. oil temperature C 110 110
Screw assembly rotary
rpm 5250 4350 3100 2500 6310 5530 4850 4500
speed
Motor power output kW 5.5 7.5
Rated motor rotary
rpm 3000 3000
speed
Supply voltage V 400 400
Thermal relay setting A 6.5 9.0
Star/delta start up time s 5 5
Cooling air requirement m3/h 1200 1200
Power lead cross
mm2 5 x 2.5 5 x 2.5
sectional area
Protection A 20 25
*) - capacity measured acc. to ISO 1217 Appendix C, 1996
**) - momentary value of acoustic pressure corrected by C characteristic does not exceed 130 dB;
- equivalent acoustic pressure level corrected by A characteristic does not exceed 85 dB(A).
3/10
1.3. DSA11 and DSA15 compressors
Compressor type DSA11 DSA15
Forced overpressure MPa 0.8 1.0 1.3 1.5 1.0 1.3 1.5
m3/h 108 87 70 55 120 96 85
Capacity*
m3/min 1.80 1.45 1.16 0.91 2.00 1.60 1.41
Weight kg 320 340
Overall dimensions
mm 790x810x1110 790x810x1110
(L x W x H)
Tank capacity l - -
Compressed air
G1/2 G1/2
connection
Compressed air
mm 799 799
connection height
0
Ambient temperature C from 5 to 40
Compressed air 0
C around 10°C above ambient temperature
temperature
Noise level L**) dB(A) 70 70
0
Max. oil temperature C 110 110
Screw assembly rotary
rpm 6240 5490 4600 4200 7200 6200 5750
speed
Motor power output kW 11 15
Rated motor rotary
rpm 3000 3000
speed
Supply voltage V 400 400
Thermal relay setting A 13 17
Star/delta start up time s 5 5
Cooling air requirement m3/h 1800 2400
Power lead cross
mm2 5x4 5x6
sectional area
Protection A 25 40
*) - capacity measured acc. to ISO 1217 Appendix C, 1996
**) - momentary value of acoustic pressure corrected by C characteristic does not exceed 130 dB;
- equivalent acoustic pressure level corrected by A characteristic does not exceed 85 dB(A).
4/10
1.4. DSA18,5 and DSA22 compressors
Compressor type DSA18,5 DSA22
Forced overpressure MPa 0.8 1.0 1.3 1.5 0.8 1.0 1.3 1.5
m3/h 190 160 132 90 220 190 162 120
Capacity*
m3/min 3.16 2.66 2.20 1.50 3.66 3.16 2.70 2.00
Weight kg 480 500
Overall dimensions
mm 1100x750x1570 1100x750x1570
(L x W x H)
Compressed air
G 3/4 G 3/4
connection
Compressed air
mm 750 750
connection height
0
Ambient temperature C from 5 to 40
Compressed air 0
C around 10°C above ambient temperature
temperature
Noise level L**) dB(A) 70 70
Screw assembly NK100 NK100
0
Max. oil temperature C 110 110
Screw assembly rotary
rpm 5240 4420 4100 3750 5750 5220 4410 3860
speed
Motor power output kW 18 22
Rated motor rotary
rpm 3000 3000
speed
Supply voltage V 400 400
Thermal relay setting A 36 44
Star/delta start up time s 7 7
Cooling air
m3/h 3000 3500
requirement
Power lead cross
mm2 5 x 10 4 x 16 + PE
sectional area
Protection A 50 50
*) - capacity measured acc. to ISO 1217 Appendix C, 1996
**) - momentary value of acoustic pressure corrected by C characteristic does not exceed 130 dB;
- equivalent acoustic pressure level corrected by A characteristic does not exceed 85 dB(A).
5/10
2. Components and views
DSA4 DSA5,5 DSA7,5 DSA11 and DSA15 screw compressors
1 – air filter, 2 – pressure sensor, 3 – oil inlet, 4 – screw assembly,
5 – belt transmission, 6 – oil drain, 7 – drive belts tensioning system (adjustment bolt on the
other side), 8 – electric motor, 9 – air and oil cooler,
10 – noise absorbing enclosure, 11 – compressed air exhaust,
12 – cooling air exhaust, 13 – control panel,
6/10
DSA18,5 and DSA22 screw compressors
1 – air filter, 2 – suction regulator, 3 – oil inlet, 4 – screw assembly,
5 – belt transmission, 6 – oil drain, 7 – drive belts tensioning system
8 – electric motor, 9 – air and oil cooler, 10 – noise absorbing enclosure,
11- compressed air exhaust, 12 – cooling air exhaust, 13 – control panel,
7/10
DSA18,5 and DSA22 screw compressors
with water cooling
1 – air filter, 2 – suction regulator, 3 – oil inlet, 4 – screw assembly,
5 – belt transmission, 6 – oil drain, 7 – drive belts tensioning system
8 – electric motor, 9 – air and oil cooler, 10 – noise absorbing enclosure,
11- compressed air exhaust, 12 – cooling air exhaust, 13 – control panel,
14 – water/oil exchanger, 15 – thermostat, 16 – water outlet, 17 – water inlet
8/10
3. Screw assembly views
NK40 screw assembly
2
3
6
7
8
9
NK60 and MS11 screw assemblies
1 – air filter, 2 – suction regulator, 3 – oil separator, 4 – minimum pressure valve, 5 – oil filter,
6 – safety valve, 7 – screw assembly body, 8 – oil inlet,
9 – oil drain,
9
1 2 6
4 10 7
NK100 screw assembly
1 – air filter, 2 – suction regulator, 3 – oil separator, 4 – minimum pressure valve, 5 – oil filter,
6 – safety valve, 7 – screw assembly body, 8 – oil inlet,
9 – air filter contamination sensor, 10 – oil drain,
9/10
4. Power supply system requirement
The compressor is designed to be supplied by a five-conductor 400 V AC, 50 Hz power line.
If only four conductor line is available, bridge the PE and N terminals in the cabinet terminal
block.
The cross sectional area of conductors should be matched to the current drawn by the
compressor.
Power lead cross Fuse size
No. Compressor type sectional area mm2 NH gL/gG, 500 V, 100 kA
D gL/gG, 500 V, 50 kA
1 DSA5,5 5 x 2.5 20
2 DSA7,5 5 x 2.5 25
3 DSA11 5x4 25
4 DSA15 5x6 40
5 DSA18,5 5 x 10 50
6 DSA22 4 x 16 + PE 50
The compressor should be supplied from a switchgear provided with a time delay fuse and a
breaker allowing to cut the power supply out completely.
Connect the compressor as specified in the attached electric diagram.
10/10