1313-H1210

GD Midea Heating & Ventilating Equipment Co., Ltd. GD Midea Heating & Ventilating Equipment Co., Ltd.
Is certified under the ISO 9001 International standard Is certified under the ISO 14001 International standard
for quality assurance. for environmental management.
NO.01 100 019209 Certificate No.15912E10020R0L

Commercial Air Conditioner Business Units


Midea Group
Add: West region of Midea commercial air conditioner department,lndustry Avenue,

Beijiao,Shunde,Foshan,Guangdong,P.R.China Postal code:528311


Tel:+86-757-22390820 Fax:+86-757-23270470
Dealer information http://global.midea.com.cn

http://www.midea.com
Note:The data in this book may be changed without notice for further improvement

on quality and performance.


Midea CAC (MCAC)
As a key part of Midea Group, the Midea Central Air Conditioner (MCAC) Business Unit is a
professional CAC products supplier and commercial products solution expert. Since 1999 Midea
central air-conditioner contributes to the commercial product R&D and technology innovation. By
cooperating with the international enterprises plus the independent R&D, Midea CAC achieves
big success in the commercial air-conditioner market and has established thousands of sample
projects all over the world.

Right now Midea CAC is one of the most professional CAC products supplier as well as the
professional project solution provider in marketing, sales, project design and after service etc.

There are three production bases in Shunde, Chongqing and Hefei.


MCAC Shunde factory with 38 product lines concentrates on the VRF (DC inverter product/
Digital scroll product), split product, heat pump water heater, AHU/FCU etc.
MCAC Chongqing factory with 14 product lines concentrates on the water cooled centrifugal /
screw/ scroll chillers, Air cooled screw/ scroll chillers, AHU/FCU etc.
MCAC Hefei factory with 11 product lines concentrates on the VRF, chillers, heat pump water
heater etc.

2004
2009

2000 2007 2011 2012


Year
2001 2006 2010
1999 2008

2012 Formed Midea-Carrier JV. Company in India and HK


2011 Formed Midea-Carrier JV. Company in Brazil
2010 Built the 3rd manufacturing base in Hefei
2009 Launched the DC inverter V4 system to the world
2008 JV with Toshiba Carrier for the DC inverter technology
2007 Won the first Midea centrifugal chiller project oversea
2006 Launched the first VSD centrifugal chiller
2004 Acquired MGRE entered the chiller industry
2001 Allied with Copeland for the Digital scroll VRF system
2000 Developed the first inverter VRF With Toshiba
1999 Started CAC business
Renewable Lineup
7-26
Heat pump is renewable and energy saving. Sanitary Hot Water
1.5~7.2kW
Hot Water

Hot Water
Sanitary

Sanitary
M-Thermal 27-38
6~14kW
M-Thermal

M-Thermal
Cool Water
Inlet
Pool Dedicated

Pool Dedicated
Series

Series
Why select HPWH?
Commercial

Commercial
Application

Application
Pool/Spa 39-43
6~90kW
Reference

Reference
Projects

Projects
Commercial Application 44-49

Comparison of the power needed to heat 1 ton water from 15˚C to 55˚C under the same conditions (Data from Midea) 10~38kW

Midea HPWH Gas Water Heater Electric Water Heater Boiler Solar Water Heater
Energy Resource Air,electricity Gas Electricity Diesel oil Solar,electricity
T
Trans ffer Factor 860kcal/kW.h 24000kcal/m3 860kcal/kW.h 10200kcal/kg 860kcal/kW.h
Average Eff
f iciency 4.6 0.8 0.95 0.7 2.7
(1/3 weather need Auxiliary Heater)

Consumption 10kW.h 2.08m3 48.9kW.h 5.6kg 17.5lkW.h


Running Cost(USD) 0.9 5.9 4.3 6.5 1.5
Merit/Demerit Green,safe,energy Risk of fire and Risk Risk electric Risk of fire and explosion, Difficult to install, takes up a
saving,friendly for explosion, emits CO2 . shocks. emits CO2 . lot of space, water tank
environment and capacity is limited.
easy for installation

03 04
S
Sanitary Hot Water 07
Contents

Hot Water
Sanitary
M
M-Thermal 27

M-Thermal
Pool Dedicated
39

Series
D
Dedicated Pool Series

Commercial
Application
Commercial Applications
C 44

Reference
Projects
Reference Projects
R 50

06
Specifications
0L(
0 L(50
0HHz)
Combo Type 190L(50Hz)
Model RSJ-15/190RDN3-C

Running mode Economy Hybrid E-heater

RSJ-15/190RDN3-C Running ambient temperature °C 5~43 -20~43 -20~43

Output water temperature °C Default 60°C,38°C~70°C


COP: 3.5
(A15/12, W15/45) Power supply 220-240~ -1 -50
V-Ph-Hz
Ambient: -20˚C~43°C
Storage size Ltr 190

Capacity kW 1.50 1.50 2.15

Water heating COP kW/kW 3.50 3.50 1.00

Max. current A 2.3 9.5

Ambient temperature °C -20~43


Hot Water

Hot Water
Sanitary

Sanitary
Dimension (D×H) mm Ф568×1,580

Unit Packing (W×H×D) mm 729×1,660×699

Net/gross weight kg 90/101

Noise level dB(A) 48

Refrigerant type/quantity kg R134a/0.8

Refrigerant design pressure MPa 3.0/1.2

Tank design pressure MPa 0.2~0.8

System protection TCO, TOD, PT valve, etc.

Combo Type Nomenclature Air flow m3/h 300

RSJ - 15 / 190 R D N3 - C Type Rotary

Brand GMCC
Design Code
Compressor Capacity kW 1.390/1.405

Refrigerant Type Input kW 0.515/0.540


N3: R134a
Brand Welling
Function Fan motor
Input W 35.5/26.5/23
D: E-Heater
Speed r/min 890/580/380
Refrigerant
Cycle-heating Type Water inlet pipe mm DN20
Water Storage (Unit: L) Water outlet pipe mm DN20

Water pipeline Drainage pipe mm DN20


Heating Capacity (Unit: ×100W)
PT valve joint mm DN20
Midea Heat Pump Water Heater
Max. operating pressure MPa 0.8

Heat exchanger Dividing wall type heat exchanger

Features E-heater kW 2.15×1

Hot water yield m3/h 0.043 0.043 0.062


R134a gas, environmentally friendly. The condenser coil is wrapped around outside the tank. Applicable persons 3~4
Output water temperature: 38°C~70 °C. No contamination potential.
Loading Quantity 20'/40'/40H Pcs 24/51/51
Multi modes: Economy, Hybrid and E-heater. Close Refrigerant circuit, easy for plumber installation.
Remark:
CE, StandardsMark, WaterMark and SAA approval. The model with wire controller(model:KJRH-90A/E) can 1. The test conditions: outdoor temperature 15/12°C(DB/WB), inlet water temperature 15°C, outlet water temperature 45°C.
2. The specifications may be changed for product improvement, please refer to the nameplate.
Automatic weekly anti-legionella function. be customized.
Multiple protection: PT valve, double high water
temperature protection switches.(Manual/Automatic)

07 08
Combo Type —190L(50Hz)
RSJ-15/190RDN3-D Specifications
Model RSJ-15/190RDN3-D
COP: 3.6
Running mode Econmy E-heater
(A15/12, W15/45)
Ambient: -20°C~45°C Running ambient temperature -7~43 -20~45
°C
Outwater Temperature °C Default 60°C,38°C~70°C
Power supply V-Ph-Hz 220-240~ -1 -50
Storage size Ltr 190
Capacity kW 1.45 3.00
Water heating COP kW/kW 3.60 1.00
Hot Water

Hot Water
Sanitary

Sanitary
Max. current A 6.5 13.0
Ambient temperature °C -20~45
Dimension (D×H) mm Ø560x1,680
Unit Packing (W×H×D) mm 695x1,725x685
Net/gross weight kg 94/110
Noise level dB(A) 41
Refrigerant type/quantity kg R134a/0.9
Refrigerant design pressure MPa 3.0/1.2
Tank design pressure MPa 0.15 ~1.2

Features System protection TCO1, TCO2, PT valve, over-load protector, etc.

R134a gas, environmentally friendly. 15 Pa air outlet pressure enables a duct length up to 5 meters Air flow m3/h 218/202/178
Water output temperature: 38ºC~70ºC. User-friendly LCD display for easy interaction. Type Rotary
Multiple modes: Economy, E-heater and Vocation. Automatic weekly anti-legionella function. Compressor Brand GMCC
Automatically select mode. Four-way valve for automatic defrosting.
Capacity kW 1.390/1.405
CE, Intertek approval. Multi protection:PT valve, double high water temperature
No contamination potential, the condenser coil is protection switches (Manual and Automatic). Input kW 0.515/0.540

wrapped around outside the tank. Close refrigerant circuit, easy for plumber installation. Fan motor
Input W 28/26/26

Speed r/min 900/815/680

Flexible duct installation Water inlet pipe mm DN20

Wate outlet pipe mm DN20


Living room Dining room Water pipeline Drainage pipe mm DN20

PT valve joint mm DN20

Max. operating pressure MPa 1.0

Heat exchanger Dividing wall type heat exchanger

E-heater 3.0
Hot water yield m3/h 0.043 0.086

Applicable persons 3~4

Loading Quantity 20'/40'/40H Pcs 24/51/51

Cellar Storage room


Remark:
1. The test conditions: outdoor temperature 15/12°C(DB/WB), inlet water temperature 15°C, outlet water temperature 45°C.
2. The specifications may be changed for product improvement, please refer to the nameplate.

09 10
Combo Type 300L(50Hz)
Specifications
RSJ-15/300RDN3 Model RSJ-15/300RDN3

Running mode Economy Hybrid E-heater

COP: 3.6 Running ambient temperature °C 5~43 -30~43 -30~43


(A15/12, W15/45) Outwater temperature °C Default 55°C,38°C~60°C
Ambient: -30°C~43°C
Power supply V-Ph-Hz 220-240~ -1 -50
Storage size Ltr 300
Capacity kW 1.50 1.50 3.00
Water heating COP kW/kW 3.60 3.60 1.00
Max. current A 3.3 16.3 13.0
Hot Water

Hot Water
Ambient temperature °C -30~43
Sanitary

Sanitary
Dimension (D×H) mm Ф650×1,920
Unit Packing (W×H×D) mm 750×2,150×780

Net/gross weight kg 110/137

Noise level dB(A) 43

Refrigerant type/quantity kg R134a/0.95

Refrigerant design pressure MPa 3.0/1.2

Tank design pressure MPa 0.15~1.2

Throttling type Electric expansion vavle

Features System protection TCO1, TCO2, PT valve, over-load protector, etc.

Air flow m3/h 414/355/312

R134a gas, environmentally friendly. 30Pa air outlet pressure enables a duct length up to 10 Type Rotary
Water output temperature: 38°C~60 °C. meters. Brand GMCC
Compressor
Multiple modes: Economy, Hybrid and E-heater. Multi protection: PT valve, double high water temperature Capacity kW 1.390/1.405
CE approval. protection switches.(Manual/Automatic).
Input kW 0.515/0.540
Automatic weekly anti-legionella function. No contamination potential, the condenser coil is
Input W 68/56/50
wrapped around outside the tank. Fan motor
Close Refrigerant circuit, easy for plumber installation. Speed r/min 620/530/465
Water inlet pipe mm DN20

Flexible duct installation Water outlet pipe mm DN20


Water pipeline Drainage pipe mm DN20
PT valve joint mm DN20
Living room Dining room
Max. operating pressure MPa 1.0
Heat exchanger Dividing wall type heat exchanger
E-heater kW 3.0

Hot water yield m3/h 0.043 0.086

Applicable persons 5~6

Loading Quantity 20'/40'/40H Pcs 21/45/45

Remark:
1. The test conditions: outdoor temperature 15/12°C(DB/WB), inlet water temperature 15°C, outlet water
temperature 45°C.
Cellar Storage room 2. The specifications may be changed for product improvement, please refer to the nameplate.

11 12
( )
Combo Type 300L(50Hz)
Specifications
RSJ-35/300RDN3-B Model RSJ-35/300RDN3-B RSJ-35/300RDN3-C

RSJ-35/300RDN3-C(1*)
Running mode Economy Hybrid E-heater Economy Hybrid E-heater

COP: 3.6 Running ambient temperature °C -7~43 -30~43 -30~43 -7~43 -30~43 -30~43
(A15/12, W15/45) Outwater temperature °C Default 55°C,38°C~60°C
Ambient: -30°C~43°C
Power supply V-Ph-Hz 220-240~ -1 -50
Storage size Ltr 300
Capacity kW 3.00 3.00 3.00 3.00 3.00 3.00
Water heating COP kW/kW 3.60 3.60 1.00 3.60 3.60 1.00
Max. current A 6.5 18.7 13.0 6.5 18.7 13.0
Hot Water

Hot Water
Ambient temperature °C -30~43
Sanitary

Sanitary
Dimension (D×H) mm Ф650×1,920
Unit Packing (W×H×D) mm 750×2,150×780

Net/gross weight kg 123/150 117/144

Noise level dB(A) 48

Refrigerant type/quantity kg R134a/1.2

Refrigerant design pressure MPa 3.0/1.2

Tank design pressure MPa 0.15~1.2

Throttling type Electric expansion valve

Features System protection TCO1, TCO2, PT valve, high-pressure protector, over-load protector , etc.

Air flow m3/h 414/355/312


Type Rotary
R134a gas, environmentally friendly. 30Pa air outlet pressure enables a duct length up to 10
Brand Mitsubishi
Water output temperature: 38°C~60 °C. meters. Compressor
Multiple modes: Economy, Hybrid and E-heater. Multi protection: PT valve, double high water temperature Capacity kW 2.785/3.355
Intertek approval. protection switches.(Manual/Automatic). Input kW 0.895/1.095
Built-in heater exchanger, compatible to Four-way valve for automatic defrosting. Input W 68/56/50
Fan motor
solar thermal or boilers.(Optional) No contamination potential, the condenser coil is
Speed r/min 620/530/465
Automatic weekly anti-legionella function. wrapped around outside the tank.
Water inlet pipe mm DN20
The model with wire controller(model:KJRH-90A/E) can Close Refrigerant circuit, easy for plumber installation.
Water outlet pipe mm DN20
be customized
Water pipeline Drainage pipe mm DN20
Flexible duct installation PT valve joint mm DN20
Max.operating pressure MPa 1.0
Living room Dining room
Heat exchanger Dividing wall type heat exchanger
Solar thermal mm DN20 /
Water inlet pipe

Water outlet pipe mm DN20 /


Solar heat exchanger Heat exchanger Stainless steel SUS316L /

Dim.×Length mm 22×10,000 /

Max. pressure MPa 0.7 /

E-heate kW 3.0

Hot water yield m3/h 0.086


Cellar Storage room Applicable persons 5~6
Loading Quantity 20'/40'/40H Pcs 21/45/45

Remark:
1. The test conditions: outdoor temperature 15/12°C(DB/WB), inlet water temperature 15°C, outlet water
temperature 45°C.
2. The specifications may be changed for product improvement, please refer to the nameplate.
NOTE:
(1*)RJS-35/300RDN3-B with solar coil
RJS-35/300RDN3-C without solar coil

13 14
Combo Type 300L(50Hz)
Specifications
RSJ-35/300RDN3-D Model RSJ-35/300RDN3-D(S) RSJ-35/300RDN3-D

RSJ-35/300RDN3-D(S)(1*) Running mode Economy E-heater Economy E-heater

Running ambient temperature °C -7~43 -20~45 -7~43 -20~45


COP: 3.6
(A15/12, W15/45) Outwater temperature °C Default 55°C,38°C~60°C
Ambient: -20°C~43°C
Power supply V-Ph-Hz 220-240~ -1-50

Storage size Ltr 300

Capacity kW 3.00 3.00 3.00 3.00

Water heating COP kW/kW 3.60 1.00 3.60 1.00

Max. current A 18.7 13.0 18.7 13.0


Hot Water

Hot Water
Ambient temperature °C -20~45
Sanitary

Sanitary
Dimension (D×H) mm Ф650×1,920

Unit Packing (W×H×D) mm 750×2,150×780

Net/gross weight kg 123/144 117/144

Noise level dB(A) 48

Refrigerant type/quantity kg R134a/1.2

Refrigerant design pressure MPa 3.0/1.2

Tank design pressure MPa 0.15~1.2

Throttling type Electric expansion valve

Features System protection TCO1, TCO2, PT valve, automatic defrosting, high-pressure protector, over-load protector, etc.

Air flow m3/h 414/355/312

R134a gas, environmentally friendly. 30Pa air outlet pressure enables a duct length up to 10 Type Rotary
Water output temperature: 38°C~60 °C. meters. Brand Mitsubishi
Compressor
Multiple modes: Economical, E-heater, and Vocation. Multi protection: PT valve, double high water temperature Capacity kW 2.785/3.355
CE,Intertek approval. StandardsMark, WaterMark protection switches.(Manual/Automatic).
Input kW 0.895/1.095
and SAA approval for RSJ-35/300RDN3-D Four-way valve for automatic defrosting.
Input W
Built-in heater exchanger, compatible to No contamination potential, the condenser coil is Fan motor
68/56/50

solar thermal or boilers.(Optional) wrapped around outside the tank. Speed r/min 620/530/465

Automatic weekly anti-legionella function. Close Refrigerant circuit, easy for plumber installation. Water inlet pipe mm DN20

Water outlet pipe mm DN20


Flexible duct installation Water pipeline Drainage pipe mm DN20

PT valve joint mm DN20


Living room Dining room
Max.operating pressure MPa 1.0
Solar thermal
Heat exchanger Dividing wall type heat exchanger

Water inlet pipe mm DN20 /

Water outlet pipe mm DN20 /

Solar heat exchanger Heat exchanger Stainless steel SUS316L /

Dim.×Length mm 22×10,000 /

Max. pressure MPa 0.7 /

E-heate kW 3.0

Cellar Storage room Hot water yield m3/h 0.086

Applicable persons 5~6

Loading Quantity 20'/40'/40H Pcs 21/45/45

Remark:
1. The test conditions: outdoor temperature 15/12°C(DB/WB), inlet water temperature 15°C, outlet water temperature 45°C.
2. The specifications may be changed for product improvement, please refer to the nameplate.
NOTE:
(1*)RJS-35/300RDN3-D(S) with solar coil
RJS-35/300RDN3-D without solar coil

15 16
Combo Type 190L(60Hz)
Specifications
RSJ-15/190RDN3-C Model RSJ-15/190RDN3-C

Running mode Economic Auto Electric


®
Running ambient temperature °F 45~115 45~115 -5~130
Ambient: -5°F~130°F
Outwater temperature °F Default 120°F,100°F~140°F

Power supply V-Ph-Hz 208-240~ -1 -60

Storage size Ltr 190

Capacity kW 1.50 1.50 4.00

Max. input kW 0.80 4.50 4.00

Water heating Ef - 2.20 2.20 0.82


Hot Water

Hot Water
FHD US Gal - 56.00 52.00
Sanitary

Sanitary
Max. current A 6.5 21.6 18.7

Ambient temperature °F -5~130

Dimension (D×H) mm Φ568×1,640

Unit Packing (W×H×D) mm 675×1750×690

Net/gross weight kg 96.5/110.6

Noise level dB(A) 48

Refrigerant type/quantity kg R134a/0.8

Refrigerant design pressure PSIA 331/86 at ambient 80°F

Features Tank design pressure PSI 150

Throttling type Thermal expansion valve

System protection TCO, TOD, PT valve, etc.


EF>2.2 (Energy Factor)rating. 5m duct length with 10 Pa.
Air flow m3/h 370/280/200
R134a gas, environmentally friendly. Multi protection: PT valve, double high water temperature
Type Reciprocating
Water output temperature: 100°F~140°F. protection switches.(Manual/Automatic).
Brand Embraco
Multiple modes: Auto mode,economic mode No contamination potential, the condenser coil is Compressor
Input kW 0.7
and electric mode. wrapped around outside the tank.
Brand Welling
UL and Energy Star approved. Close Refrigerant circuit, easy for plumber installation.
Fan motor Input W 40

Duct length up to 5 meters Speed r/min 970/750/550

Water inlet pipe NPT 3/4

Water outlet pipe NPT 3/4


Water pipeline
Drainage pipe NPT 3/4

PT valve joint NPT 3/4

Max. pressure MPa 1.0

E-heater kW 4.0×2

Loading Quantity 20'/40'/40H Pcs 24/51/51

Remark:
1. The test conditions: 10 CFR Part 430 Energy Conservation Program for Consumer Products: Test Procedure for Water Heaters
2. The specifications may be changed for product improvement, please refer to the nameplate.

17 18
Combo Type 300L(60Hz)
Specifications
RSJ-35/300RDN3 Model RSJ-35/300RDN3

Running mode Economy E-heater

Running ambient temperature °C -7~43 -20~45


COP: 3.5
(A15/12, W15/45) Outwater Temperature °C Default 55°C,38°C~60°C
Ambient: -20°C~45°C
Power supply V-Ph-Hz 220~ -1 -60

Storage size Ltr 300

Capacity kW 3.40 3.00

Water heating COP kW/kW 3.50 1.00

Max. current A 7.6 13.0


Hot Water

Hot Water
Sanitary

Sanitary
Ambient temperature °C -20~45

Dimension (D×H) mm Ф650×1,920

Unit Packing (W×H×D) mm 750×2,150×780

Net/gross weight kg 117/148

Noise level dB(A) 48

Refrigerant type/quantity kg R134a/1.2

Refrigerant design pressure MPa 3.0/1.2

Tank design pressure MPa 0.15~1.2

Throttling type Electric expansion valve

Features System protection TCO1, TCO2, PT valve, over-load protector, etc.

Air flow m3/h 414/355/312

R134a gas, environmentally friendly. Multiple protection: PT valve, double high water tempera- Type Rotary

Water output temperature: 38°C~60 °C. ture protection switches.(Manual/Automatic). Brand Mitsubishi
Compressor
Multiple modes: Economy, E-heater. Four-way valve for automatic defrosting. Capacity kW 2.785/3.355
Built-in heater exchanger, compatible to No contamination potential, the condenser coil is
Input kW 0.895/1.095
automatic weekly anti-legionella function. wrapped around outside the tank.
Input W 68/56/50
30Pa air outlet pressure enables a duct length up Close Refrigerant circuit, easy for plumber installation. Fan motor

to 10 meters. Speed r/min 620/530/465

Water inlet pipe mm DN20

Water outlet pipe mm DN20


Flexible duct installation Water pipeline Drainage pipe mm DN20

PT valve joint mm DN20


Living room Dining room Max. operating pressure MPa 1.0

Heat exchanger Dividing wall type heat exchanger

E-heater kW 3.0

Hot water yield m3/h 0.094 0.086

Applicable persons 5~6

Loading Quantity 20'/40'/40H Pcs 21/45/45

Remark:
Cellar Storage room 1. The test conditions: outdoor temperature 15/12°C(DB/WB), inlet water temperature 15°C, outlet water temperature 45°C.
2. The specifications may be changed for product improvement, please refer to the nameplate.

19 20
Split Type (Water Cycle) Specifications
Contents Model RSJF-30/CN3

RSJF-30/CN3 Running mode Economy E-heater (1*)

Power supply V-Ph-Hz 220-240~ -1 -50


Ambient temperature °C -7~45 -20~45
COP: 3.26
(A20/15, W15/55) Output water temperature °C 60°C
Ambient: -20°C~43°C
Storage size of optional tank Ltr 200~400
Capacity kW 3.0 3.6
Input kW 0.92 3.6
Water heating COP kW/kW 3.26 1.00
Rate power input kW 1.40 /
Max. current A 6.8 16
Hot Water

Hot Water
Sanitary

Sanitary
Dimension (WxHxD) mm 617x1,058x360

Outdoor unit Packing (WxHxD) mm 735x1,105x430


Net/gross weight kg 70/73
Outdoor noise level dB(A) 52
Refrigerant type/quantity kg R134a/0.75
Refrigerant design pressure MPa 2.7/ 1.0

Air flow m3/h 1400


Type Rotary
re
Split Type Nomenclature Brand Mitsubishi
Compressor

RSJ F - 32 / C N1 A Capacity
Input
kW
kW
2.785/3.355
0.895/1.095
Brand Fans-tech
Fan motor Input W 65/35
Design Code Speed r/min 860/610

Refrigerant Type Water inlet pipe mm DN20


Water pipeline
N1: R410A Water outlet pipe mm DN20
N3: R134a
Omit: R22 Hot water yield m3/h 0.65 0.77

Function Type Loading Quantity 20'/40'/40H Pcs 30/63/84


C: Water Cycle with Water Pump
Remark:
R: Refrigerant Cycle
1. The test conditions: outdoor temperature 20/15°C(DB/WB), inlet water temperature 15°C, outlet water temperature 55°C.
Heating Capacity (UNIT: ×100W) 2. The specifications may be changed for product improvement, please refer to the nameplate.
Note:
Split Type 1* Available for the tank with 3.6kW E-heater.

Midea Heat Pump Water Heater

Features
COP of 3.26 energy saving. Automatic anti-freezing.
R134a gas environmentally friendly. Close refrigerant circuit, easy for plumber installation.
Electronic expansion valve for throttling ,high efficiency. Double-wall heat exchanger to prevent refrigerant leakage.
Easy control and restart function. Flexible installation.
Four-way valve for automatic defrosting.

21 22
Split Type (Water Cycle)
Specifications
RSJ-15/190RDN3-C

RSJF-32/CN3-A Model RSJF-32/CN3-A RSJF-32/CN1-B RSJF-50/CN1-B RSJF72/CN1-B

RSJF-32/CN1-B 220-240~ -1 -50 220-240~ -1 -50 220-240~ -1 -50 220-240~ -1 -50


Power supply V-Ph-Hz
RSJF-50/CN1-B
Ambient temperature °C -7~43 -15~43 -15~43 -7~43
RSJF-72/CN1-B
Outwater Temperature °C Default 50°C, 40°C~70°C Default 50°C, 40°C~60°C

Storage size of optional tank Ltr 100~500

Capacity kW 3.00 3.00 4.30 6.50

Input kW 0.98 0.81 1.11 1.80


Water heating
COP kW/kW 3.06 3.70 3.87 3.61

Max. current A 7.3 7.5 8.3 15.3


Hot Water

Hot Water
Dimension (W×H×D) 790×765×275 790×765×275 790×765×275 845×945×335
Sanitary

mm

Sanitary
Outdoor unit Packing (W×H×D) mm 905×807×355 905×807×355 905×807×355 965×1,009×395

Net/gross weight kg 60/64 56/60 62/66 81/86.5

Outdoor noise level dB(A) 53 53 55 55

Refrigerant type/quantity kg R134a/0.75 R410A/0.95 R410A/1.2 R410A/1.3

Refrigerant design pressure MPa 2.7/1.0 4.4/2.6 4.4/2.6 4.4/2.6

Tank design pressure MPa 0.2~0.7

Throttling type Electric expansion valve Electric expansion valve Electric expansion valve Electric expansion valve

Air flow m³/h 2,000 2,000 2,000 3,200

Type Rotary Rotary Rotary Rotary

Features Brand Mitsubishi GMCC GMCC GMCC

Compressor Capacity kW 2.880/3.520 2.780/2.815 3.910/3.930 5.870/5.960

R134a/R410A gas, environmentally friendly. Double-wall heat exchanger to prevent refrigerant leakage. Input kW 1.030/1.300 0.955/0.995 1.350/1.400 1.985/2.055

Max. water output temperature: 60°C(R410A). Built-in water pump. Fan motor
Input W 74/51 74/51 74/51 134/60

CE approved. Close Refrigerant circuit, easy for plumber installation. Speed r/min 770/ 480 770/ 480 770/ 480 830/450

Four-way valve for automatic defrosting. User-friendly control interface,easy to control Water inlet pipe mm DN20 DN20 DN20 DN20

Water pipeline Water outlet pipe mm DN20 DN20 DN20 DN20

Double-wall heat exchanger Water circulating pipe mm DN20 DN20 DN20 DN20

Storage size of suggested tank Ltr 100~300 100~300 150~350 300~500

Hot water yield m³/h 0.075 0.074 0.107 0.155

Loading Quantity 20'/40'/40H Pcs 76/160/240 76/160/240 76/160/240 64/134/134

Model (Water tank) LSX-260XP/D LSX-300XP/D LSX-350XP/D LSX-400XP/D

Storage size L 260 300 350 400

Dimension mm Φ560×1,623 Φ560×1,853 Φ630×1,667 Φ630×1,884

Packing (W×H×D) mm 630×1,710×635 630×1,960×635 690×1,760×705 690×1,980×705

Net/gross weight kg 49/57 55/63 55/64 66/76

Loading Quantity 20'/40'/40H Pcs 30/63/84 27/54/72 27/60/60 24/54/54

Remark:
1. The test conditions: outdoor temperature 7/6°C(DB/WB), inlet water temperature 30°C, outlet water temperature 35°C.
2. The test conditions of hot water yield : outdoor temperature 20/15°C(DB/WB), inlet water temperature 15°C, outlet water temperature 55°C.
3. The specifications may be changed for product improvement, please refer to the nameplate.

23 24
Specifications
Split Type (Refrigerant Cycle)
Model RSJF-32/R-B RSJF-50/R-C

Power supply V-Ph-Hz 220-240~ -1 -50 220-240~ -1 -50


RSJF-32/R-B
Ambient temperature °C -7~46 -7~46
RSJF-50/R-C
Output water temperature °C Default 50°C, 40°C~55°C
Tank: 150/200/260L Storage size of optional tank Ltr 150/200 200/260
Ambient: -7°C~46°C
Capacity kW 3.10 5.10

Input kW 0.826 1.325

Water heating COP kW/kW 3.75 3.85

Max. current A 5.7 7.9

Dimension (W×H×D) mm 700×534×234 780×547×261

Outdoor unit Packing (W×H×D) mm 825×585×375 915×570×385


Hot Water

Hot Water
Sanitary

Sanitary
Net/gross weight kg 28/30 35/40
Outdoor noise level dB(A) 49 52
Refrigerant type/quantity kg R22/0.95 R22/1.60
Refrigerant design pressure MPa 2.6/1.2 2.6/1.2

Type Rotary Rotary

Brand GMCC GMCC


Compressor
Capacity kW 2.560/2.595 4.225/4.260

Input kW 0.800/0.830 1.340/1.430

Input W 67/55 74/51


Fan motor
Speed r/min 840/500 770/480

Features Water pipeline


Water inlet pipe mm DN15 DN15

Water outlet pipe mm DN15 DN15


Max. outlet water temperature:55°C. Easy to operate and easy to control
Hot water yield m³/h 0.068 0.107
No contamination potential, the condenser coil
Model (Water Tank) PLSX-150(32)TP-B PLSX-200(32)TP-B PLSX-200(50)TP-B PLSX-260(50)TP-B
is wrapped around outside of the enamel tank.
Packing (W×H×D) mm 1,605×570×575 1,725×605×615 1,820×665×675 1,820×665×675
Easy for installation and maintenance.
Net/gross weight kg 60/68 70/75 71/79.5 86.5/96.5

Remark:

High efficiency
1. The test conditions: outdoor temperature 20/15°C(DB/WB), initial water temperature 15°C, terminate water temperature 55°C.
2. The specificationS may be changed for product improvement, please refer to the nameplate.

25 26
Water tank
M-Thermal LSX - 300 (50) XP / S D 15 B11
Design Code
E-Heater Capacity (Unit: ×100W)
Unit with E-Heater
Power Supply Code
380-415V~,3Ph,50Hz
n ta
ary
a ryy Hot Water Tank
Sanitary
Omit: 220-240V~,1Ph,50Hz
Spraying Appearance with
DC
D Inverter Outdoor
doo Unit
utd Stainless Steel Inner Tank
Heating Capacity of Main Unit (Unit: ×100W)
Hydraulic Indoor Unit
Solar Kit Water Tank Volume (Unit: L)
Midea Vertical Water Tank

Features
M-Thermal

M-Thermal
R410A gas, environmentally friendly.
DC Inverter Technology.
M-Thermal
Th l Nomenclature
N l The advancement of the inverter technology creates more quiet, economical and powerful air conditioning systems.
1,DC Inverter Outdoor Unit
Temperature / Power input
Temperature remains stable
L RSJ F - V 120 / S N1 - 610
Slow
start Non-inverter system
Design Code
Refrigerant Type
Set temperature Inverter system
N1: R410A
Power Supply Code
S: 380-415V~,3Ph,50Hz
Omit: 220-240V~,1Ph,50Hz Time

Heating Capacity (Unit: ×100W)


Inverter Type Automatic Weekly Anti-legionella Function
Split Type
Midea Heat Pump Water Heater
Unit with Cooling Function

2,Hydraulic indoor unit


SMK - 120 / C S D 80 G N1
Refrigerant Type
N1: R410A
Floor heating
E-Heater Capacity (Unit: ×100W)
Unit with E-Heater
Power Supply Code
S: 380-415V~,3Ph,50Hz
Omit: 220-240V~,1Ph,50Hz
Water-Cycle-Heating Type
Heating Capacity (Unit: ×100W)
Hydraulic Indoor Unit

29 30
Specifications
Hydraulic Indoor Unit SMK-120/CD30GN1 SMK-100/CD30GN1 SMK-80/CD30GN1 SMK-60/CD30GN1
Compatible with Solar Thermal and Boilers Power supply V-Ph-Hz 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50
Types Heating&Cooling Heating&Cooling Heating&Cooling Heating&Cooling
Total Heating Solution Space Heating °C 15~55 15~55 15~55 15~55
Function Space Cooling °C 7~22 7~22 7~22 7~22
When floor heating is conducted in a new house, warm air spreads gently across the house, making it comfortable and enabling
Sanitary Hot Water °C 35~60 35~60 35~60 35~60
the use of broad space without necessitating radiators or FCU.
Max. current A 13.5 13.5 13.5 13.5
Noise level dB(A) 32 32 32 32
Low Running Costs Dimension (W×H×D) mm 500×900×375 500×900×375 500×900×375 500×900×375
Unit Packing (W×H×D) mm 1,110×610×510 1,110×610×510 1,110×610×510 1,110×610×510
When you use a gas or oil boiler, or an electric radiator, you can get exactly the same effect based on your input. The price of
Net/gross weight kg 63/75 63/75 63/75 60/72
electricity is stable relative to those of oil or gas, thus cutting more costs as the time passes.
Size kW 1.5+1.5 1.5+1.5 1.5+1.5 1.5+1.5
E-heater
Quantity Pcs 2 2 2 2
Best Heating Efficiency Water inlet pipe mm DN32 DN32 DN32 DN32
Water pipeline
M-thermal, with the application of the same amount of energy, emits more than four energy items, which can be used. This is the Water outlet pipe mm DN32 DN32 DN32 DN32
Loading Quantity 20'/40'/40H Pcs 66/138/184 66/138/184 66/138/184 66/138/184
strength of the Air to Water Heat pump to which inverter technology is applied.
DC Inverter Outdoor Unit LRSJF-V120/N1-610 LRSJF-V100/N1-610 LRSJF-V80/N1-310 LRSJF-V60/N1-310
Power supply V-Ph-Hz 220-240~ -1-50 220-240~ -1-50 1-220~240-50 220-240~ -1-50
Max. current A 23 22 15 14
Capacity kW 12 10 8 6
Energy Efficiency Comparison Heating COP kW/kW 4.31 4.3 4.08 4.15
Ambient temperature °C -15~43 -15~43 -15~43 -15~43
Capacity kW 9.0 8.5 6.3 5.5
M-Thermal

M-Thermal
4.31 4.3 Cooling EER kW/kW 2.45 2.45 2.23 2.45
COP

4.13 4.17 4.08 4.08 4.15 Ambient temperature °C 15~43 15~43 15~43 15~43

Energy Dimension (W×H×D) mm 900×1,327×348 900×1,327×348 895×862×313 895×862×313


More than Efficiency Unit Packing (W×H×D) mm 1,030×1,456×435 1,030×1,456×435 1,025×910×410 1,025×910×410
4 times Factor Net/gross weight kg 89/101 89/101 66/70 66/70
Noise level dB(A) 58 58 58 58
Type/quantity kg R410A/2.7kg R410A/2.7kg R410A/2.4kg R410A/2.4kg
Refrigerant
System pressure MPa 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6
Type Twin-Rotary Twin-Rotary Twin-Rotary Twin-Rotary
14 kW 12 kW 12 kW 10 kW 8 kW 8 kW 6 kW Compressor Brand Mitsubishi Mitsubishi Mitsubishi Mitsubishi
(3 Ph) (3 Ph) (3 Ph) Capacity 7.130
0.8~0.9 kW 9.880 9.880 7.130
Input W 107×2 107×2 168/146 168/146
Fan motor
Speed r/min 800 800 877/749 877/749
Other Heating System Electric Heater, Boiler Loading Quantity 20'/40'/40H Pcs 28/58/58 28/58/58 60/126/126 60/126/126
Sanitary Hot Water Tank LSX-300XP/D30B11 LSX-200XP/D30B11 LSX-150XP/D30B7 LSX-150XP/D30B7
Power supply Ph-V-Hz 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50
Convenient and Reliable System Storage size Ltr 200 (Optional 150/300) 150 (Optional 300/200)
300 (Optional 150/200) 150 (Optional 300/200)
1. M-thermal uses the Easy Controller to check detailed operational information and a change in temperature of the whole system. Max. water output temperatue °C 60 60 60 60
2. Easy to handle and install. Dimension (D×H) mm Ф580×1,800 Ф580×1,320 Ф580×1,050 Ф580×1,050
3. Reliable Performance at lower temperatures. Packing (W×H×D) mm 1,885×670×670 1,400×670×670 1,135×670×670 1,135×670×670
Net/Gross weight kg 75/94 60/68 49/58 49/58
E-heater kW 3.0 3.0 3.0 3.0
Comfort System
Tank material SUS304 SUS304 SUS304 SUS304
1. When floor heating is applied, warm air spreads gently across the house, making it comfortable. The system can help blood Water inlet pipe mm DN20 DN20 DN20 DN20
circulation and metabolism, further boosting our health. Water pipeline Water outlet pipe mm DN20 DN20 DN20 DN20

2. The System is a four-season solution that can provide a heating solution in general and at the same time it also provides a cooling PT valve joint mm DN20 DN20 DN20 DN20

solution in summer. Loading Quantity 20'/40'/40H Pcs 27/57/76 27/57/76 27/57/76 27/57/76
Solar Kit TMK-01 TMK-01 TMK-01 TMK-01
3. M-Thermal does not require oil or gas tank, making the household surrounding neat and safe, enabling the use of more space,
Power supply V-Ph-Hz 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50
and avoiding refueling.
Dimension (W×H×D) mm 810×310×295 810×310×295 810×310×295 810×310×295
Packing (W×H×D) mm 830×340×315 830×340×315 830×340×315 830×340×315
Net weight kg 8/10 8/10 8/10 8/10
OD×T mm×mm Ф22×0.8 Ф22×0.8 Ф22×0.8 Ф22×0.8
Length m 11 11 11 11
Solar coils Material SUS316L SUS316L SUS316L SUS316L
Inlet pipe mm DN20 DN20 DN20 DN20
Outlet pipe mm DN20 DN20 DN20 DN20
Loading Quantity 20'/40'/40H Pcs 300/624/728 300/624/728 300/624/728 300/624/728
The testing Condition:
1. Heating: Outdoor temperature 7/6°C(DB/WB), inlet water temperature 30°C, outlet water temperature 35°C.
2. Cooling: Outdoor temperature 35/24°C(DB/WB), inlet water temperature 12°C, outlet water temperature 7°C.
3. The specifications may be changed for product improvement, please refer to the nameplate.

31 32
Specifications
Hydraulic Indoor Unit SMK-140/CSD80GN1 SMK-120/CSD80GN1 SMK-80/CSD80GN1
Operation Temperature Range
Power supply V-Ph-Hz 380-415~ -3-50 380-415~ -3-50 380-415~ -3-50
Types Heating&Cooling Heating&Cooling Heating&Cooling Set the system at the following temperatures for maximum efficiency. The maximum operating temperature of the heat pump.
Space Heating °C 15~55 15~55 15~55 (Cooling/Heating)
Function Space Cooling °C 7~22 7~22 7~22
Sanitary Hot Water °C 35~60 35~60 35~60
Max. current A 20 20 16 Model Outdoor temperature Water temperature
Noise level dB(A) 32 32 32
Dimension (W×H×D) mm 500×900×375 500×900×375 500×900×375 Cooling operating 15ºC~43ºC 7ºC ~ 22ºC
Unit Packing (W×H×D) mm 1,110×610×510 1,110×610×510 1,110×610×510
Net/gross weight kg 63/75 63/75 64/77 Heating operating (Single phase) -15ºC~43ºC 15ºC~55ºC
Size kW 4.0+4.0 4.0+4.0 4+3.5
E-heater
Quantity Pcs 2 2 2
Heating operating (Three phase) -20ºC~43ºC 15ºC~55ºC
Water inlet pipe mm DN32 DN32 DN32
Water pipeline
Water outlet pipe mm DN32 DN32 DN32
Loading Quantity 20'/40'/40H Pcs 66/138/184 66/138/184 66/138/184
DC Inverter Outdoor Unit LRSJF-V140/SN1-610 LRSJF-V120/SN1-610 LRSJF-V80/N1-310-B
Power supply
Max. current
V-Ph-Hz
A
380-415~ -3-50
9.0
380-415~ -3-50
9.0
220-240~ -1-50
16
ACCESSORIES
Capacity kW 14 12 8
Outdoor Unit
Heating COP kW/kW 4.13 4.17 4.08
Ambient temperature °C -20~43 -20~43 -20~43
Name Shape Quantity

FITTINGS
M-Thermal

M-Thermal
Capacity kW 8.8 8.8 6.3 Outdoor unit
1
Cooling EER kW/kW 2.28 2.22 2.33 installation manual
Ambient temperature °C 15~43 15~43 15~43
Outdoor unit
Dimension (W×H×D) mm 900×1,327×348

INSTALLATION
900×1,327×348 895×862×313 1
owner’s manual
Unit Packing (W×H×D) mm 1,030×1,456×435 1,030×1,456×435 1,025×910×410
Net/gross weight kg 89/101 89/101 63/67 Outflow
1
connecting tube
Noise level dB(A) 58 58 58
Type/quantity kg R410A/2.7kg R410A/2.7kg R410A/2.4kg
Refrigerant
Waterproof 1
System pressure MPa 4.4/2.6 4.4/2.6 4.4/2.6 rubber cap
Type Twin-Rotary Twin-Rotary Twin-Rotary
Compressor Brand Mitsubishi Mitsubishi Mitsubishi Hydraulic Indoor Unit
Capacity kW 9.880 9.880 7.130
Accessory name Shape Quantity
Input W 107×2 107×2 168/146
Fan motor
Speed r/min 800 800 877/749 Owner's & Installation Manual 1
Loading Quantity 20'/40'/40H Pcs 28/58/58 28/58/58 60/126/126
Sanitary Hot Water Tank LSX-300XP/D15B11 LSX-300XP/D15B11 LSX-300XP/SD15B11 Mounting bracket 1
Power supply V-Ph-Hz 220-240~ -1-50 220-240~ -1-50 380-415~ -3-50 Two-way valve 3
Storage size Ltr 300 300 300
Max. water output temperatue °C 60 60 60 M4 screw 2
Dimension (D×H) mm Ф580×1,800 Ф580×1,800 Ф580×1,800
Water tank temperature sensor 1
Packing (W×H×D) mm 1,885×670×670 1,885×670×670 1,885×670×670
Y-style filter
Net/Gross weight kg 80/91 80/91 80/91 Floor heating inlet 1
E-heahter kW 1.5 1.5 1.5
Temperature sensor, T1B 1
Tank material SUS304 SUS304 SUS304
Water inlet pipe mm DN20 DN20 DN20 Drain pan kit 1
Water pipeline Water outlet pipe mm DN20 DN20 DN20
PT valve joint mm DN20 DN20 DN20 M8 expansion screw 5
Loading Quantity 20'/40'/40H Pcs 27/57/76 27/57/76 27/57/76
Solar Kit TMK-01 TMK-01 TMK-01
Power supply 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50
Solar Kit
V-Ph-Hz
Dimension (W×H×D) mm 810×310×295 810×310×295 810×310×295 Accessory name Shape Quantity Purpose
Packing (W×H×D) mm 830×340×315 830×340×315 830×340×315
Installation & Owner’s Manual 1
Net weight kg 8/10 8/10 8/10
2 Connection the solar kit and
OD×T mm×mm Ф22×0.8 Ф22×0.8 Ф22×0.8 adapter the sanitary hot water tank.
Length m 11 11 11
Sealing 6 Pipe connection seal.
Solar coils Material SUS316L SUS316L SUS316L
Inlet pipe mm DN20 DN20 DN20
Screw 2 Fixed left and right epp casing.
Outlet pipe mm DN20 DN20 DN20
Loading Quantity 20'/40'/40H Pcs 300/624/728 300/624/728 300/624/728 Washer 2 Fixed left and right epp casing.
The testing Condition:
1. Heating: Outdoor temperature 7/6°C(DB/WB), inlet water temperature 30°C, outlet water temperature 35°C.
2. Cooling: Outdoor temperature 35/24°C(DB/WB), inlet water temperature 12°C, outlet water temperature 7°C.
3. The specifications may be changed for product improvement, please refer to the nameplate.
33 34
Installation Diagram Wired controller (KJRH-120A/BT-E)
M-thermal+ Radiator + Underfloor Heating + Sanitary Tank The system can be combined with: Features
1. Under floor heating. Turning the unit ON/OFF. Selection of features:
2. Radiator. Operation mode change-over: Silent mode
3. Low temperature radiators to provide the maximize comfort for users.
Space heating Run test function
4. A sanitary hot water tank to supply hot water needs.
Space cooling Air purge function
Sanitary water heating Temperature set point adjustment.
Space heating & Sanitary water heating The clock functions are:
Space cooling & Sanitary water heating 24 hours real time clock
Day of the week indicator
Schedule timer function.
Temp.

Name and Function of Buttons


M-Thermal

M-Thermal
Button Name Function

Cooling/Heating ON/OFF button. Starts or stops the heating or cooling function of the unit.

w Weekly schedule timer button. Enable /disable the schedule time and use to program the controller.
M-thermal + Radiator + Underfloor Heating + Sanitary Tank + Solar Panel The system can
be combined with: Silent mode button. Enable or disable silent mode.

1. Under floor heating. Clock setting button. Enable or disenable clock setting.
2. Radiator.
3. Low temperature radiators to provide the maximize comfort for users. Sanitary water heating button. Enable or disable heating of the sanitary water.
4. A sanitary hot water tank to supply hot water needs.
5. Solar collectors with optional solar kit, to compliment the production of hot water. Sanitary hot water temperature setting button. enable or disable sanitary water temperature setting.

Space cooling/Space heating button. This button allows manual switching between cooling or heating mode.

Space cooling/Space heating temperature setting button. Enable or disable space cooling/space heating temperature setting.

Menu button. Enable and disable menu setting function of the controller.

Check button. Enables and disenable the checking function of the controller.
Solar Panel
Prev
Page up button. This button is used for page up function.

Next
Temp.
Page down button. This button is used for page down function.


Increasing button. This button is used for increasing the current value.


Decreasing button. This button is used for decreasing the current value.

OK
Confirm button. Press this button to confirm the change.

Lock button. Press this button for locking all other buttons.
lock

Reset
Reset button. Reset the wire controller and return to factory default settings.

35 36
Name and Function of Icons Name and Function of Icons

Icon Function Error code Meaning

This icon indicates the current operation mode is space cooling. E0 Flow switch error( continuous for 3 times,and should be reset without power supply )

E1 T2 error
This icon indicates the current operation mode is space heating.

E2 UI communication error
This icon indicates the current operation mode is sanitary water heating.
E3 Outdoor unit communication error
This icon indicates that the circulation pump is running.
E4 T2B error
This icon indicates that the compressor in the outdoor unit is active.
E5 T5 error
This icon indicates the current operation mode is silent mode.
E6 T1 error
This icon indicates that the disinfection mode is active.
E7 T1B error

This icon indicates that the defrost mode is active. E8 Flow switch(one time)

This icon indicates that the anti-freezing mode is active.


M-Thermal

M-Thermal
E9 TW_in error

1 2 3 4 EA TW_out error
▼ ▼ ▼ ▼ ▼ ▼ ▼
These icons indicate the operation and the date of the weekly schedule timer.
SUN MON TUE WED THU FRI SAT

This icon indicates that the electric heater of the sanitary water tank is active. Eb T4 error

This icon indicates that the first stage auxiliary heater of the indoor unit is operating Ed Phase protection
when there is a high demand for heating capacity.
EE Eeprom error
This icon indicates that the second stage auxiliary heater of the indoor unit is operating when there is a
high demand for heating capacity.
P0 T2 high temperature protection
The display shows the current set temperature of the installation.
P1 T2B low temperature protection
The display also used to shows the water outlet temperature of indoor unit when there is no button press
operation. P2 TW_out high temperature protection
These icons indicate that external heat source(s) is (are) installed.
P3 TW_out low temperature protection

This icon indicates that an external room thermostat with higher priority is controlling your installation. P4 TW_in high temperature protection

The clock display shows the current time. P5 T1 high temperature protection

The first code and the second represent the first level and the second level menu from the field set list. P6 T1B high temperature protection
The last two numbers indicate the value of the first and the second code.

The operation lamp lights in each one mode. P7 Outdoor unit protection

P8 Sanitary hot water tank electric heater protection


This icon indicates the checking parameter is the inlet temperature of floor heating.
P9 Auxiliary heater protection
These two icons indicate the current operation mode are space
& cooling and sanitary water heating.
Pb Anti- freezing protection
These two icons indicate the current operation mode are space
& heating and sanitary water heating.
Pc Temperature controller error(result from the conflict between cool mode and heat mode)
This icon indicates all the operations of the schedule timer are inactive.
t0~t7 Run test

This icon indicates all the buttons of the controller are locked except button.
dF Defrost

This icon is displayed whenever non-installed option is addressed or a function is not available.
d0 Oil return function

37 38
Domestic Pools & Spas
LRSJ-60/NYN1
LRSJ-80/NYN1
LRSJ-120/NYN1
LRSJ-140/NYN1

Ambient

Dedicated Pool Series Heating: -7°C~38°C


Cooling: 15°C~43°C

Nomenclature

Pool Dedicated
L RSJ - 60 / N Y N1

Series
Refrigerant Type
N1: R410A
Available for pool

Water Cycle without Water Pump

Heating Capacity (Unit: ×100W)

Midea Heat Pump Water Heater


Unit with Cooling Function

Titanium Heat Exchanger

40
Features
Titanium Heat exchanger. 15 m wire controller available.
Commercial Pools/Spas
LCD display. Automatic defrosting function.
CE approved. Heating and cooling mode. LRSJ-450/SY
LRSJ-900/SY
Operation Temperature Range Ambient
Heating: -7°C~43°C
Water cooling Outdoor temperature 15°C~43°C
Cooling: 21°C~43°C
Water heating Outdoor temperature -7°C~38°C

Unit Selection
Capacity(kW) 6 8 12 14
Applicable range(m3) 20 25 40 45~50

Remarks:
Outdoor temperature: 33.5°C, design water temperature of pool: 28°C, temperature of water supply: 16°C, quantity of water supply: 3%, wind speed on the water surface: 0.35m/s,
system-loss-factor: 5%, the first water-heating time: 24h~48h.

Specifications
Model LRSJ-60/NYN1 LRSJ-80/NYN1 LRSJ-120/NYN1 LRSJ-140/NYN1

Power supply V-Ph-Hz 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50 220-240~ -1-50

Heating mode Water outlet temperature °C Default 28°C, 20°C~35°C

Cooling mode °C Default 28°C, 10°C~30°C


Features
Pool Dedicated

Pool Dedicated
Water outlet temperature

6.3 8.0 13.7 16.0


Series

Series
Max. current A

Capacity kW 6 8 12.0 14.0


Highly efficient scroll compressor . Cooling, heating and hot water, providing a total water
Input kW 1.15 1.52 2.40 2.55
Heating Titanium tube heat exchanger . supply solution.
Ambient temperature °C -7~38 -7~38 -7~38 -7~38
Water temperature: 7~43°C. Include an automatic defrosting function.
COP kW/kW 5.22 5.27 5.00 5.49

Capacity
Wire controller is easy to set and operate. LCD Automatic freezing function for water pipe.
kW 4.0 5.8 8.4 10.4

Input kW 1.3 1.5 2.4 2.9 display and a clock. Easy to install and simple maintain.
Cooling
Ambient temperature °C 15~43 15~43 15~43 15~43 Swimming pool heating and constant temperature system Central hot water supply system Refrigeration/heating system
EER kW/kW 3.2 3.9 3.5 3.6
Terminal device
Dimension (W×H×D) mm 1,015×705×385 1,015×705×386 1,050×855×315 1,050×855×315 electormagnetic valve
Cycle inlet
Outdoor unit Packing (W×H×D) mm 1,095×840×445 1,095×840×445 1,160×980×410 1,160×980×410 temp.sensor water tank water level
Cycle outlet water supply
Net/Gross weight kg 64/73 66/75 75/85 75/85

Max. power kW 1.45 1.9 3.3 3.5 filter water supply Cycle water inlet Cycle water outlet

Dosing pump filter water supply


Outdoor noise level dB(A) 58 58 58 58 cycle pump pool series water pump
Cycle water pump
Refrigerant type/Quantity kg R410A/1.0 R410A/1.25 R410A/1.6 R410A/1.85

Heat exchanger material Titanium-tube

Water inlet pipe mm DN50 DN50 DN50 DN50


Operation Temperature Range
Water side Water outlet pipe
Outdoor temperature 21°C~43°C
mm DN50 DN50 DN50 DN50 Cooling
Drain pipe diameter
Indoor temperature ≥17°C
mm DN25 DN25 DN25 DN25

Max. pressure
Outdoor temperature 7~43°C
MPa 0.4 0.4 0.4 0.4 Heating
Water inlet temperature 0~40°C
Wire controller KJRH-90B/E KJRH-90B/E KJRH-90B/E KJRH-90B/E

Loading Quantity 20'/40'/40H Pcs 52/108/162 52/108/162 56/116/116 56/116/116


Unit Selection
Remark:
1. The test conditions: Capacity (kW) 45 90
Water Heating: outdoor temperature 24/19°C(DB/WB), inlet water temperature 27°C, outlet water temperature 29°C
Applicable range (m3) 150 300
Water Cooling: outdoor temperature 35/24°C(DB/WB), inlet water temperature 27°C, the water flow volumn is same in both cooling and heating mode.
2. The specifications may be changed for product improvement, please refer to the nameplate. Remarks:
Outdoor temperature: 33.5°C, design water temperature of pool: 28°C, temperature of water supply: 16°C, quantity of water supply: 3%, wind speed on the water surface: 0.35m/s,
system-loss-factor: 5%, the first water-heating time: 24h~48h.

41 42
Specifications
Model LRSJ-450/SY-820 LRSJ-900/SY-820

Power supply V-Ph-Hz 380~ -3-50 380~ -3-50

Heating mode Water outlet temperature °C Default 28°C, 20°C~40°C

Cooling mode Water outlet temperature °C Default 28°C, 7°C~30°C

Heating
Capacity

Input

Ambient temperature
kW

kW

°C
45

8.5

-7~43
90

16.4
Commercial Heat Pump
COP kW/kW 5.29 5.49

Capacity kW 40 80

Input kW 11.5 20.5


Cooling
Ambient temperature °C 21~43

EER kW/kW 3.48 3.90

Outdoor noise level dB(A) 65 67

Refrigerant type/Quantity kg R22/7kg R22/14kg

Heat exchanger material Titanium-tube

Water inlet pipe mm DN50 DN100


water side
Water outlet pipe mm DN50 DN100

Max. pressure MPa 1.0 1.0

Dimension (W×H×D) mm 1,514×1,820×850 2,000×1,970×900

Outdoor unit Packing (W×H×D) mm 1,620×2,041×1,034 2,110×2,150×1,000


Pool Dedicated

Net/gross weight kg 380/400 580/650


Series

Wire controller KJRH-08B/H KJRH-08B/H

Hot Water Yield m3/h 15 30

Loading Quantity 20'/40'/40H Pcs 6/14/14 5/12/12

Remark:
1. The test conditions:
Water Cooling: outdoor temperature 24/19°C(DB/WB), inlet water temperature 27°C,outlet water temperature 29°C
Water Heating: outdoor temperature 35/24°C(DB/WB), inlet water temperature 27°C
2. The specifications may be changed for product improvement, please refer to the nameplate.

Engineering Applications

Spillway
Water supply
Swimming pool
Outlet
Inlet

Cycle pump

Pool series units

Filter Filter

43
Each units applies refrigerant heating technology Double throttling technology ensures the temperature
Direct &Cycle Heating (R410A) to increase the total energy absorb. of the base plate.

Double throtling technology

Absorb from E-heater

Ambient: -15°C~43°C Absorb from air


-35ºC
RSJ-380/SN1-820-D RSJ-380/PN1-820(60Hz)

RSJ-100/N1-540V-D Compressor input power -7ºC


RSJ-200/SN1-540V-D
Compressor heat storage

convention double heating


defrosting source defrosting 15ºC

Compressor Parallel technology (Avialable for RSJ-380/SN1-820-D)


Compressor exhaust

Gas balance

Nomenclature
RSJ - 380 / P N1 - 820

Compressor l

Compressor ll
Design Code

Refrigerant Type
N1: R410A

Power Supply Code


S:380-415V~, 3Ph, 50Hz Oil balance Compressor suction
Commercial

Commercial
P: 380V~, 3Ph, 60Hz
Application

Application
Omit: 220-240V~, 1Ph, 50Hz Simple refrigerating system diagram
Heating Capacity (Unit: × 100W)

Midea Heat Pump Water Heater Heat pump units schematic diagram

Sent to the user


Features Hot water inlet Hot water outlet

Heat pump Heat pump Heat pump


R410A gas, environmentally friendly. heating heating heating
Free modular combination. water 0# water 1# water 15#
Unique defrosting flow path. unit unit unit
Air side reserved special defrosting flow path, when the system is defrosting, the four-way valve is reversing , the
outlet

To drain ditch
system will absorb energy from special defrosting flow path, the defrosting progress will have no impact on water
Water Water
temperature. outlet inlet
High efficiency compressor. inlet
For 50Hz units, Copeland’s efficient scroll compressor.
For 60Hz unit, Danfoss’s efficient scroll compressor.
Flexible design, low temperature design guarantees performance.
Proprietary gas balance and fluid balance design to ensure the unit operates reliably.
Tap water
Hot water valve supplies hot water at a stable temperature and expands the life of compressor.
50Hz units are CE certified. A maximum of 16 heat pump heating water units can be connected in parallel. (Except RSJ-380/PN1-820 is 4 units.)

45 50
46
Schematic diagram of single connected heat pump system Wired Controller (KJRH-16C-A/E)
Dimension
Sent to the user

Hot water inlet Hot water outlet


Features
Easy control.
The timing startup function.
Heat Pump water Water tank
outlet
Heating Water Valve Set outlet water temperature from 40°C to 60°C .
Unit LCD display.
joint T5
water water sensor water Display the clock and timing startupa time signal.
outlet One way
inlet Filter inlet Valve Valve Power-off memory function.
joint
Pump Display error code and check operation parameter.
To drain Auxiliary
ditch heater(optional) Filter
Manom-
Cleansing
eter Return
valve
pump
Name of Keys on the Wire Controller
RSJ-100/N1-540V-D
Tap water
single connected for RSJ-200/SN1-540V-D
RSJ-380/SN1-820-D
RSJ-380/PN1-820

8 ON/OFF

Specifications
Model RSJ-100/N1-540V-D RSJ-200/SN1-540V-D RSJ-380/SN1-820-D RSJ-380/PN1-820 WATER LEV. 1 9 WATER TEMP.

Power supply V-Ph-Hz 220-240~ -1-50 380-415~ -3-50 380-415~ -3-50 380~ -3-60 CONFIRM 2 14 INCREASE
Running ambient temperature °C -15~43
Outwater temperature °C Default 56°C, 40°C~60°C
kW 11.2 20.4 43.0 42.0
CLOCK 3 15 PAGE UP
Capacity
Input kW 2.98 5.23 10.40 10.70
Water Heating TIMER 4
COP kW/kW 3.76 3.90 4.13 3.93 12 PAGE DOWN
Max. input current A 17.8 13.0 28.0 26.0
CANCEL 5
Commercial

Commercial
13 DECREASE
Application

Application
Dimension (W×H×D) mm 750×1,100×700 750×1,100×750 992×1,750×893 997×1,771×894
Outdoor unit Packing (W×H×D) mm 770×1,145×770 770×1,145×770 1,100×1,965×920 1,100×1,965×920
CHECK 6 10 CYC.TEMP.
Net/gross weight kg 121 / 135 148 / 163 305 / 328 283 / 310
Outdoor noise level dB(A) 59 63 65 65
Refrigerant type/quantity kg R410A/1.5 R410A/2.8 R410A/5.7 R410A/5.0
MPa
RESET 7 11 LOCK
Design pressure 4.4/2.6 4.4/2.6 4.4/2.6 3.7/2.2
Type/quantity Scroll/1 Scroll/1 Scroll/2 Scroll/1
Brand Copeland Copeland Copeland Danfoss
Compressor Capacity kW 8.8 16.2 16.2 32.1
Number Name Function
Input kW 2.94 5.20 5.20 9.957
Brand Welling Yongan or Dayang Yongan Dayang 1 WATER LEV. Set the outdoor water level.
Outdoor fan motor Input×quantity W 237/156 ×1 294/250 ×1 865/725×1 850/730×1 2 CONFIRM Confirm and finishi the last operation.
Speed r/min 735 / 530 930 / 770 830 / 710 780/660 3 CLOCK Set or adjust the clock.
Outdoor air flow (0Pa) m3/h 4,618 5,929 10,342 8,644 4 TIMER Set timer on or timer off.
water inlet pipe mm DN25 DN25 DN25 DN25 5 CANCEL CanceI all the timing hours, the related timing display will be disappeared.
water outlet pipe mm DN25 DN25 DN25 DN25 Query the status information of any units. Even under defaults, press it to query the aspecifi unit.
Water pipeline 6 CHECK
Max. resisting pressure Mpa 1.0 1.0 1.0 1.0 7 RESET Cancell the current setting, the wire controller enters the reset status.
Min. resisting pressure Mpa 0.12 0.12 0.12 0.12
8 ON/OFF In the power-off status, press this key once to startupa the unit. In the startup status, press it to shutdown the unit.
Wire controller KJRH-16C-A/E KJRH-16C-A/E KJRH-16C-A/E KJRH-16C-A/E
9 WATER TEMP. Press this key to enter the procedure of setting water temperature signals.
Hot water yield m3/h 0.25 0.45 0.92 0.89
10 CYC. TEMP. This key is used to set the inlet temperature of the circulating heating water.
Loading quantity 20'/40'/40H Pcs 21/42/84 21/42/84 12/26/26 12/26/26
11 LOCK Press this bottun to lock the current setting, and press it again to unlock.
Remark:
1. The test conditions: outdoor temperature 20/15°C(DB/WB), inlet water temperature 15°C, outlet water temperature 55°C.
2. The specifications may be changed for product improvement, please refer to the nameplate.

47 48
Name and function description of LCD screen of wired controller
RUN E-HEATING ANTI-COLD ERROR

CIRCULATING CHECK LOCK SETTING WATER LEVEL

RUN

CLOCK WATER LEVEL STATE

TIMER PARAMETER DISPLAY MAIN INTERFACE QTY. OF ON-LINE UNITS

Installation Procedure
The wiring procedure and principles are shown in the figure:
Choose the wiring mode according to your actual model.
Wiring mode I Wiring mode II
Wire controller 5-bit terminals base
of water heater Black
5-bit terminals base
Black
Yellow White
Red
Brown
Gray Black
Yellow
Black
Minor 8-bit
terminal base Wire controller
of water heater g Electric control box
re of water heater
Electric control box
of water heater

The whole wire controller installation


Commercial

Wire Controller Turn a screwdriver at the concave on bottom panel


Application

Back Cover of the Wire Controller to remove the Back Cover

Wire Controller
Top Cover
Holes matche with the
86X86 Wiring box

Wire Controller
Board

Reference
Projects
Wire Controller
Bottom Cover

Wood Mounting
Screw (M4X20)

Fault Code List


E0 Inlet water pressure detection fault(Only main equipment).
E1 Power supply wire phase fault.
E2 Communication fault.
E3 Error of outlet water temperature.
E4 Error of the water temperature sensor inner the water tank.
E5 Error of the pipe of condenser temperature.
E6 Error of a outdoor ambient temperature.
E7 Error of a electric heater temperature.
E8 Error of detecting circulating water pressure.
EE Communication error of function locking module and main board.
EF EEPROM error.
P0 System low pressure protection.
P1 System high pressure protection.
P2,P3 System current protection.
P8 Over high outlet water temperature protection.
PF Function locking module is under locking state.

49 50