MD520 AC Drive

High performance universal AC drive

■ Unified AC asynchronous and PM synchronous motor control

■ Wide operating voltage and product range:

•3 ph 380-480 Vac: 0.4 to 500 kW


•3 ph 200-240 Vac: 0.4 to 75 kW
•1 ph 200-240 Vac: 0.4 to 2.2 kW

■ STO SIL 3 PL e

■ Built-in DC reactor (400 V: 18.5 kW and above;


200 V: 11 kW and above)

■ Enhanced reliability: conformal coated PCBs compliant to


3S2 and 3C3 environments
■ Complies to efficiency level IE2 as defined in IEC 61800-9-2
IE2 STO
■ Through-hole mounting options (0.4 to 160 kW)
E467465
IND. CONT. EQ.
MD520 - features & functions

■ Induction motor and PM synchronous motor control: ■ Category C2 compliance with external RFI filter.
•Open loop V/F (induction motors only) and SVC Ratings with built-in filter comply with
•Closed loop FVC Category C3*1

■ Dual rated: heavy duty (overload: 150%/ 1 min) ■ Simplified parameters for easy start up

and normal duty (overload: 110%/ 1 min) ■ 4 independent S-ramps

■ Starting torque ■ Flexible programmable I/Os


•150% at 0.25 Hz for SVC ■ User programmable functions
•180% at 0 Hz for FVC ■ Variable DC-injection braking
■ Communication options: ■ Comprehensive trip diagnostics
•Modbus-RTU ■ Output frequency: 599 Hz
•Modbus-TCP ■ Built-in dynamic braking unit
•PROFIBUS-DP ■ Bipolar analog input as standard (-10 to +10 V)
•CANopen ■ PTC input as standard
•CANlink ■ Application dedicated functions:
•PROFINET •Master-slave function (torque, speed)
•EtherCAT •Textile wobble control
•Ethernet/IP ■ Brake control logic
■ 4 motor parameter sets
■ Automatic torque boost
■ PC-based software: simplified start up & backup*2

*1 For detailed EMC compliance information, consult your local


Inovance representative
*2 USB to RS485 adapter required. MDKE-10 or SOP-20 keypads
can be used for this purpose

NEW: built-in colour LED keypad


■ The clearest possible information display

■ Displays multiple pieces of information


simultaneously (e.g. drive status and
operating information)

■ User friendly with additional keys

*
*
General specifications

Heavy duty ratings, ���% overload


Voltage class Three phase 380 to 480 Vac

Drive model:
0.4B(S) 0.7B(S) 1.1B(S) 1.5B(S) 2.2B(S) 3.0B(S) 3.7B(S) 5.5B(S) 7.5B(S) 11B(S) 15B(S)
MD520-4TxxxB(S)-INT
Frame size T1*1 T2 T3 T4

Rated input voltage Three phase 380 to 480 Vac -15% to +10%
Drive input

Rated input current [A] 1.8 2.4 3.7 4.6 6.3 9.0 11.4 16.7 21.9 32.2 41.3

Power capacity [kVA] 2 2.8 4.1 5.0 6.7 9.5 12 17.5 22.8 33.4 42.8

Rated input frequency 50/60 Hz ±5%

Applicable motor [kW] 0.4 0.75 1.1 1.5 2.2 3.0 3.7 5.5 7.5 11 15
Output current [A]*2 1.5 2.1 3.1 3.8 5.1 7.2 9.0 13.0 17.0 25.0 32.0
Drive output

Default carrier frequency [kHz] 6 6 6 6 6 6 6 6 6 6 6

Overload capacity 150% for 60 s


Max. output voltage Three phase 380 to 480 Vac (proportional to input voltage)

Max. output frequency 599 Hz

Recommended power [kW] 0.08 0.14 0.22 0.3 0.44 0.6 0.74 1.1 1.5 2.2 3
Braking
resistor

Minimum resistance [Ω] 96 96 96 96 64 64 32 32 32 24 24

Braking unit Built-in


Enclosure IP 20

Normal duty ratings, ���% overload


Voltage class Three phase 380 to 480 Vac

Drive model: 0.4B(S) 0.7B(S) 1.1B(S) 1.5B(S) 2.2B(S) 3.0B(S) 3.7B(S) 5.5B(S) 7.5B(S) 11B(S) 15B(S)
MD520-4TxxxB(S)-INT
Frame size T1*1 T2 T3 T4
Rated input voltage Three phase 380 to 480 Vac -15% to +10%
Drive input

Rated input current [A] 2.5 3.7 4.6 6.4 9.1 11.3 15.9 22.4 32.9 39.7 44.0
Power capacity [kVA] 2.3 3.4 4.2 5.9 8.3 10.4 15.5 20.5 30.2 38.2 44.4
Rated input frequency 50/60 Hz ±5%

Applicable motor [kW] 0.75 1.1 1.5 2.2 3.0 3.7 5.5 7.5 11 15 18.5

Output current [A]*2 2.1 3.1 3.8 5.1 7.2 9.0 13.0 17.0 25.0 32.0 37.0
Drive output

Default carrier frequency [kHz] 6 6 6 6 6 6 6 6 6 6 6

Overload capacity 110% for 60 s

Max. output voltage Three phase 380 to 480 Vac (proportional to input voltage)

Max. output frequency 599 Hz

Recommended power [kW] 0.08 0.14 0.22 0.3 0.44 0.6 0.74 1.1 1.5 2.2 3
Braking
resistor

Minimum resistance [Ω] 96 96 96 96 64 64 32 32 32 24 24


Braking unit Built-in
Enclosure IP 20

*1 0.75/1.5/2.2 kW are the preferred stocking ratings. To learn more, please get in touch with your local Inovance representative.
*2 Rated output current at default carrier frequency.

3
General specifications

Heavy duty ratings, ���% overload


Voltage class Three phase 380 to 480 Vac

Drive model: 18.5 22


30(B)(S) 37(B)(S) 45(B)(S) 55(B)(S) 75(B)(S) 90(S) 110(S) 132(S) 160(S)
MD520-4Txxx(B)(S)(-T)-INT (B)(S)(-T) (B)(S)(-T)

Frame size T5 T6 T7 T8 T9

Rated input voltage Three phase 380 to 480 Vac -15% to +10%
Drive input

Rated input current [A] 43.4 51.3 57 69 89 106 139 164 196 240 287

Power capacity [kVA] 45 54 52 63 81 97 127 150 179 220 263

Rated input frequency 50/60 Hz ±5%

Applicable motor [kW] 18.5 22 30 37 45 55 75 90 110 132 160


Output current [A] *2
37 45 60 75 91 112 150 176 210 253 304
Drive output

Default carrier frequency [kHz] 6 6 6 5 5 4 3 3 3 3 3


Overload capacity 150% for 60 s
Max. output voltage Three phase 380 to 480 Vac (proportional to input voltage)

Max. output frequency 599 Hz

Recommended power [kW] 4.5 4.5 6 7 9 11 15 18 22 26 32


Braking
resistor

Minimum resistance [Ω] 24 24 19.2 14.8 12.8 9.6 6.8 11.4x2*3 7.7 x2*3 7.7 x2*3 2.8 x2*3
Braking unit Built-in MDBUN- MDBUN-90-5T x2 MDBUN-
60-5T x2 200-5T x2
Enclosure IP 20

Normal duty ratings, ���% overload


Voltage class Three phase 380 to 480 Vac

Drive model: 18.5 22


30(B)(S) 37(B)(S) 45(B)(S) 55(B)(S) 75(B)(S) 90(S) 110(S) 132(S) 160(S)
MD520-4Txxx(B)(S)(-T) (B)(S)(-T) (B)(S)(-T)

Frame size T5 T6 T7 T8 T9

Rated input voltage Three phase 380 to 480 Vac -15% to +10%
Drive input

Rated input current [A] 51.3 65.8 71 86 111 143 167 198 239 295 359
Power capacity [kVA] 54 60 65 79 102 131 153 181 219 270 328

Rated input frequency 50/60 Hz ±5%

Applicable motor [kW] 22 30 37 45 55 75 90 110 132 160 200


Output current [A]*2 45 60 75 91 112 150 176 210 253 304 377
Drive output

Default carrier frequency [kHz] 6 6 6 5 5 4 3 3 3 3 3

Overload capacity 110% for 60 s


Max. output voltage Three phase 380 to 480 Vac (proportional to input voltage)
Max. output frequency 599 Hz
Recommended power [kW] 4.5 4.5 6 7 9 11 15 18 22 26 32
Braking
resistor

Minimum resistance [Ω] 24 24 19.2 14.8 12.8 9.6 6.8 11.4 x2 *3


7.7 x2 *3
7.7 x2 *3
2.8 x2*3
Braking unit Built-in MDBUN- MDBUN-90-5T x2 MDBUN-
60-5T x2 200-5T x2
Enclosure IP 20

*2 Rated output current at default carrier frequency. *


*3 Minimum value of the resistance for each braking unit. *
*

4
General specifications

Heavy duty ratings, ���% overload


Voltage class Three phase 380 to 480 Vac

Drive model:
200(S) 220(S) 250(S) 280(S) 315(S) 355(S) 400(S)
MD520-4Txxx(S)-INT*4
Frame size T10 T11 T12

Rated input voltage Three phase 380 to 480 Vac -15% to +10%
Drive input

Rated input current [A] 365 410 441 495 565 617 687

Power capacity [kVA] 334 375 404 453 517 565 629

Rated input frequency 50/60 Hz ±5%


Applicable motor [kW] 200 220 250 280 315 355 400
Output current [A]*2 377 426 465 520 585 650 725
Drive output

Default carrier frequency [kHz] 3 3 3 3 3 3 3


Overload capacity 150% for 60 s
Max. output voltage Three phase 380 to 480 Vac (proportional to input voltage)
Max. output frequency 599 Hz

Recommended power [kW] 42 54 60 69 78 87 87


Braking
resistor

Minimum resistance [Ω] 2.8 x2 *3


2.8 x2 *3
2.8 x3 *3
2.8 x3 *3
2.8 x3 *3
2.8 x3 *3
2.8 x3*3
Braking unit MDBUN-200-5T x2 MDBUN-200-5T x3
Enclosure IP 00

Normal duty ratings, ���% overload


Voltage class Three phase 380 to 480 Vac

Drive model:
200(S) 220(S) 250(S) 280(S) 315(S) 355(S) 400(S)
MD520-4Txxx(S)-INT*4
Frame size T10 T11 T12

Rated input voltage Three phase 380 to 480 Vac -15% to +10%
Drive input

Rated input current [A] 456 507 559 624 708 782 840
Power capacity [kVA] 417 464 511 571 647 715 768
Rated input frequency 50/60 Hz ±5%
Applicable motor [kW] 250 280 315 355 400 450 500

Output current [A]*2 465 520 585 650 725 820 880
Drive output

Default carrier frequency [kHz] 3 3 3 3 3 3 3

Overload capacity 110% for 60 s


Max. output voltage Three phase 380 to 480 Vac (proportional to input voltage)
Max. output frequency 599 Hz
Recommended power [kW] 42 54 60 69 78 87 87
Braking
resistor

Minimum resistance [Ω] 2.8 x2 *3


2.8 x2 *3
2.8 x3 *3
2.8 x3 *3
2.8 x3 *3
2.8 x3 *3
2.8 x3*3
Braking unit MDBUN-200-5T x2 MDBUN-200-5T x3
Enclosure IP 00

*2 Rated output current at default carrier frequency.


*3 Minimum value of the resistance for each braking unit.
*4 For the standard AC drive, we recommend motor cable lengths to be <100 m. Where your installation exceeds 100 m, the“L”version is an option with a built-in AC output
reactor (1% voltage drop) which can help to overcome the effects of long cable installations. To discuss your application, contact your local Inovance representative.

5
General specifications

Heavy duty ratings, ���% overload


Voltage class Three phase 200 - 240 Vac

Drive model: 0.4 0.7 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37
45(S) 55(S)
MD520-2Txxx(B)(S)-INT B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S)

Frame size T1 T2 T3 T4 T5 T6 T7 T8

Rated input voltage Three phase 200 to 240 Vac -15% to +10%
Drive input

Rated input current [A] 2.4 4.6 6.3 9.0 11.4 16.7 32.2 41.3 51.3 57 69 89 106 139 164 196

Power capacity [kVA] 1.1 2.1 2.9 4.1 5.2 7.6 14.7 18.9 27 26.1 31.6 40.7 48.5 63.6 75 89.6

Rated input frequency 50/60 Hz ±5%

Applicable motor [kW] 0.4 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Output current [A] *2
2.1 3.8 5.1 7.2 9.0 13 25 32 45 60 75 91 112 150 176 210
Drive output

Default carrier frequency [kHz] 6 6 6 6 6 6 6 6 6 6 5 5 4 3 3 3

Overload capacity 150% for 60 s

Max. output voltage Three phase 200 to 240 Vac (proportional to input voltage)

Max. output frequency 599 Hz

Recommended power [kW] 0.09 0.16 0.25 0.34 0.5 0.8 1.3 1.7 2.3 3.0 3.9 4.6 5.5 6.8 5.0 x2 6.0 x2
Braking
resistor

Minimum resistance [Ω] 48 48 32 32 16 16 12 12 12 9 7 6 5 4 5.5 x2*3 3.7 x2*3

Built-in MDBUN- MDBUN-


Braking unit 60-2T x2 90-2T x2
Enclosure IP 20

Normal duty ratings, ���% overload *


Voltage class Three phase 200 - 240 Vac

Drive model: 0.4 0.7 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37
45(S) 55(S)
MD520-2Txxx(B)(S)-INT B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S) B(S)

Frame size T1 T2 T3 T4 T5 T6 T7 T8
Rated input voltage Three phase 200 to 240 Vac -15% to +10%
Drive input

Rated input current [A] 3.7 6.4 9.1 11.3 15.9 22.4 39.7 44 65.8 71 86 111 143 167 198 239
Power capacity [kVA] 1.7 2.9 4.2 5.2 7.3 10.2 18.2 20.1 30.1 32.5 39.3 50.8 65.4 76.4 90.5 109.3
Rated input frequency 50/60 Hz ±5%
Applicable motor [kW] 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Output current [A]*2 3.1 5.1 7.2 9.0 13 17 32 37 60 75 91 112 150 176 210 253
Drive output

Default carrier frequency [kHz] 6 6 6 6 6 6 6 6 6 6 5 5 4 3 3 3


Overload capacity 110% for 60 s
Max. output voltage Three phase 200 to 240 Vac (proportional to input voltage)
Max. output frequency 599 Hz
Recommended power [kW] 0.09 0.16 0.25 0.34 0.5 0.8 1.3 1.7 2.3 3.0 3.9 4.6 5.5 6.8 5.0 x2 6.0 x2
Braking
resistor

Minimum resistance [Ω] 48 48 32 32 16 16 12 12 12 9 7 6 5 4 5.5 x2*3 3.7 x2*3

Braking unit Built-in MDBUN- MDBUN-


60-2T x2 90-2T x2
Enclosure IP 20

*2 Rated output current at default carrier frequency.


*3 Minimum value of the resistance for each braking unit.

6
General specifications

Heavy duty ratings , ���% overload


Voltage class One phase 200 - 240 Vac

Drive model:
0.4B(S) 0.7B(S) 1.5B(S) 2.2B(S)
MD520-2SxxxB(S)-INT
Frame size T2

Rated input voltage One phase 200 to 240 Vac -15% to +10%
Drive input

Rated input current [A] 5.4 8.2 14 20

Power capacity [kVA] 1.4 2.2 3.7 6

Rated input frequency 50/60 Hz ±5%

Applicable motor [kW] 0.4 0.75 1.5 2.2

Output current [A]*2 2.3 4.0 7.0 9.6


Drive output

Default carrier frequency [kHz] 6 6 6 6

Overload capacity 150% for 60 s

Max. output voltage Three phase 200 to 240 Vac (proportional to input voltage)

Max. output frequency 599 Hz

Recommended power [kW] 0.08 0.08 0.1 0.1


Braking
resistor

Minimum resistance [Ω] 64 64 32 32

Braking unit Built-in

Enclosure IP 20

*2 Rated output current at default carrier frequency.

-
General wiring diagram

T�-T�� frames:
T�-T� frames � ph ��� V: �� - �� kW (HD)
� ph ��� V: �.� - �.� kW (HD) � ph ��� V: �� - ��� kW (HD)
� ph ��� V: �.� - �� kW (HD) Braking resistor
� ph ��� V: �.� - �� kW (HD)
Braking
Braking resistor unit
- +
Circuit Protection
breaker Contactor fuse - + BR
L� U

L� S V M

L� T W

+��V
PG
J�
OP
feedback
option
card port

DI�

DI�

DI�-DI� standard DI�


digital inputs
DI�
J�� RJ��
DI� high-speed DI� Remote keypad interface
digital input (SOP-�� LCD keypad, MDKE-�� LED keypad)

AO�
COM Analog output �: �~�� V/�~�� mA
【注】
S� GND Selectable by S� DIP switch
AM

Grounding copper bar �V

}
+��V FM When used as high-speed pulse output,
the maximum frequency is up to ��� kHz;
�~� kΩ AI� When used as an open-collector output,
COM it has the same specifications as DO�
S�
AI�: �~�� V, -�� V~+�� V (voltage mode) AI�
S�

}
�~�� mA (current mode),default voltage S�
mode (selectable by DIP switch) DO�
In current mode, the input impedance Open collector output �: �~�� Vdc/�~�� mA
(��� Ω or ��� Ω) can be selected by DIP switch.
GND
Motor temperature detection, supports CME
PT���, PT����, KTY-��-���, PTC-���
T/C
Relay output:
T/B ��� Vac, �� mA - � A
�� Vdc, �� mA - � A
T/A
J��
I/O extension
or communication
STO� STO function terminals can be connected
option card port
to internal �� V or external �� V.
STO�
When using internal �� V, STO� and STO�
+��VSTO are connected to +��VSTO
COM When using external �� V, STO� and STO�
are connected to external +�� V, disconnect from +��VSTO.

8
Dimensions

MD520-4T0.4B(S)-INT to MD520-4T15B(S)-INT MD520-4T18.5B(S)-INT to MD520-4T37B(S)-INT


MD520-2T0.4B(S)-INT to MD520-2T7.5B(S)-INT MD520-2T11B(S)-INT to MD520-2T18.5B(S)-INT
MD520-2S0.4B(S)-INT to MD520-2S2.2B(S)-INT

W 4 W 4 D
A d× D d×
A

B H
B H

MD520-4T45B(S)-INT to MD520-4T160(S)-INT
MD520-4T200(S)-INT
MD290T200G-INTto MD520-4T400(S)-INT
to MD290T450G-INT
MD520-2T22B(S)-INT to MD520-2T55(S)-INT MD290T220P-INT to MD290T500P-INT

W D A1 ØD1
W 4 D

A

H1 H B1
B H

A2

62 B2

W1

MD520-4T200(S)-L-INT to MD520-4T400(S)-L-INT

W ØD1
D A1

H1 H B1

A2

B2

62

W1

9
Frame Dimensions (mm) Mass
MD520 Model
size
A A1 B B1 H H1 W W1 D D1
(kg) P
MD520-4T0.4B(S)-INT, MD520-4T0.7B(S)-INT, MD520-4T1.1B(S)-INT
I
MD520-4T1.5B(S)-INT, MD520-4T2.2B(S)-INT, MD520-4T3.0B(S)-INT, T1 119 / 189 / 200 / 130 / 152 Ø5 1.6
I
MD520-2T0.4B(S)-INT, MD520-2T0.7B(S)-INT
c
MD520-2T1.1B(S)-INT, MD520-2T1.5B(S)-INT F
MD520-4T3.7B(S)-INT, MD520-4T5.5B(S)-INT
MD520-2S0.4B(S)-INT to MD520-2S2.2B(S)-INT T2 119 / 189 / 200 / 130 / 162 Ø5 2.0
MD520-2T2.2B(S)-INT, MD520-2T3.7B(S)-INT
MD520-4T7.5B(S)-INT, MD520-4T11B(S)-INT, MD520-2T5.5B(S)-INT T3 128 / 238 / 250 / 140 / 170 Ø6 3.3
MD520-4T15B(S)-INT, MD520-2T7.5B(S)-INT T4 166 / 266 / 280 / 180 / 170 Ø6 4.3
MD520-4T18.5B(S)-INT, MD520-4T22B(S)-INT, MD520-2T11B(S)-INT T5 195 / 335 / 350 / 210 / 192 Ø6 10
MD520-4T30B(S)-INT, MD520-4T37B(S)-INT
T6 230 / 380 / 400 / 250 / 220 Ø7 17.5
MD520-2T15B(S)-INT, MD520-2T18.5B(S)-INT
MD520-4T45B(S)-INT, MD520-4T55B(S)-INT
T7 245 / 523 / 525 542 300 / 275 Ø10 35
MD520-2T22B(S)-INT, MD520-2T30B(S)-INT
MD520-4T75B(S)-INT, MD520-4T90(S)-INT, MD520-4T110(S)-INT
T8 270 / 560 / 554 580 338 / 315 Ø10 51.5
MD520-2T37B(S)-INT, MD520-2T45(S)-INT, MD520-2T55(S)-INT
MD520-4T132(S)-INT, MD520-4T160(S)-INT T9 320 / 890 / 874 915 400 / 320 Ø10 85
MD520-4T200(S)-INT
MD520-4T220(S)-INT 240 150 1,035 86 1,086 1,134 300 360 500 Ø13 110
T10
MD520-4T200(S)-L-INT 240 150 1,035 424 1,424 1,472 300 360 500 Ø13 160
MD520-4T220(S)-L-INT
MD520-4T250(S)-INT, MD520-4T280(S)-INT
225 185 1,175 97 1,248 1,284 330 390 545 Ø13 155
MD520-4T250(S)-L-INT T11 225 185 1,175 435 1,586 1,622 330 390 545 Ø13 215
MD520-4T280(S)-L-INT
MD520-4T315(S)-INT, MD520-4T355(S)-INT, MD520-4T400(S)-INT
240 200 1,280 101 1,355 1,405 340 400 545 Ø16 185
MD520-4T315(S)-L-INT, MD520-4T355(S)-L-INT T12
240 200 1,280 432 1,683 1,733 340 400 545 Ø16 245
MD520-4T400(S)-L-INT

Option cards and mounting position

Feedback option cards

MDKE-10 SOP-20
I/O extension option cards

MD38IO1 MD38IO2 MD38IO3


I/O card 1 I/O card 2 I/O card 3 Feedback card slot

MD38PGMD MD38PG4 ES510-PG-CT1

Multifunctional Resolver 23-bit encoder

Communication option cards

MD38CAN1 MD38CAN2 MD38TX1 MD38DP2 MD-SI-DP1 MD500-PN1 MD500-ECAT MD500-EN1 MD500-EM1


CANlink card CANopen Modbus PROFIBUS-DP PROFIBUS-DP PROFINET EtherCAT card Ethernet card Modbus TCP
card RTU card card card card Extension or comms card slot

10
PC software tools
InoDriverShop

InoDriverShop is Inovance’s free of charge PC-based software offering. It is based on a familiar Windows interface. InoDriverShop
can upload anddownload drive parameters, and features a variety of other functions, such as a real-time oscilloscope.
For the connection with the PC a standard USB to RS485 adapter can be used. MDKE-10 or SOP-20 keypads can also be used for this purpose.

Parameter uploading/downloading Multi channel oscilloscope

Accessories list

Category Model Function description Suitable for


MDBUN-60-5T External braking unit, rated current 60 A, for supply input voltage 380 to 480 Vac AC drives. T models: 90G
External MDBUN-90-5T External braking unit, rated current 90 A, for supply input voltage 380 to 480 Vac AC drives. T models: 110G - 132G
braking MDBUN-200-5T External braking unit, rated current 200 A, for supply input voltage 380 to 480 Vac AC drives. T models: 160G - 450G
units MDBUN-60-2T External braking unit, rated current 60 A, for supply input voltage 200 to 240 Vac AC drives. 2T models: 45G
MDBUN-90-2T External braking unit, rated current 90 A, for supply input voltage 200 to 240 VAC AC drives. 2T models: 55G
MDKE-10 Remote LED keypad. Can be used as USB to RS485 adapter for the connection to the PC. All
Includes MDCAB cable.
SOP-20 Remote multi-language LCD keypad. For parameter programming and monitoring, All
data copy. Keypad can be used as USB to RS485 adapter for the connection to the PC. Includes
MDCAB cable.
Keypads MDCAB 3 meter connection cable for remote keypad. All
MDCAB-1.5 1.5 meter connection cable for remote keypad. All
CP600-BASE1 Panel mounting base (only) for SOP-20 keypad. IP20 rating. All
SOP20-MP-IP20 Panel mounting base for SOP-20 keypad, including adapting metal plate and PCB protection plate. All
IP20 rating.
SOP20-MP-IP54 Panel mounting base for SOP-20 keypad, including PCB protection plate and rubber seals. IP54 rating. All
MD580-AZJ1 Panel mounting base for MDKE-10. IP20 rating. All
MD38IO1 I/O extension card 1, provides: 5x DI, 1x AI, 1x relay output, 1x DO, 1x AO, Modbus-RTU and CANlink. Frame sizes T4-T12
I/O extension
MD38IO2 I/O extension card 2, provides 3x extra DI terminals. All
cards
MD38IO3 I/O extension card 3, provides 3x DI, 1x relay output, Modbus-RTU interface. All
MD500-ECAT EtherCAT option card. All
MD500-EN1 Ethernet option card. All
MD38CAN1 CANlink option card, supports only CANlink. All
Fieldbus MD38CAN2 CANopen option card, supports only CANopen. All
cards MD38TX1 Modbus-RTU option card. All
MD38DP2 PROFIBUS-DP option card. Frame sizes T4-T12
MD500-EM1 Modbus TCP option card. All
MD-SI-DP1 PROFIBUS-DP option card (designed for smaller frames). All
MD500-PN1 PROFINET option card. All
MD38PG4 Option card for resolver (10 kHz excitation) with DB9 connector. All
MD38PGMD Multifunctional encoder option card, compatible with differential, open-collector and All
PG cards
push-pull encoder types. Supports differential output and open-collector output.
ES510-PG-CT1 23-bit encoder card. All
MD500-AZJ-A1T1 Through hole mounting bracket for frame T1. Frame size T1
MD500-AZJ-A1T2 Through hole mounting bracket for frame T2. Frame size T2
MD500-AZJ-A1T3 Through hole mounting bracket for frame T3. Frame size T3
MD500-AZJ-A1T4 Through hole mounting bracket for frame T4. Frame size T4
Mounting
MD500-AZJ-A1T5 Through hole mounting bracket for frame T5. Frame size T5
brackets
MD500-AZJ-A1T6 Through hole mounting bracket for frame T6. Frame size T6
MD500-AZJ-A1T7 Through hole mounting bracket for frame T7. Frame size T7
MD500-AZJ-A1T8 Through hole mounting bracket for frame T8. Frame size T8
MD500-AZJ-A1T9 Through hole mounting bracket for frame T9. Frame size T9
Guide rails MD500-AZJ-A3T10 Guide rails for inserting in/ extracting from the cabinet - frame sizes T10 to T12. Frame sizes T10-T1211
Driven by technology
AC drives AC MultiDrives MV drives

Single-Axis servos Multi-Axis servos Robotics & motion controllers

PLCs & HMIs CNC machine tool solutions Electric vehicle inverters

International Offices
Germany-Stuttgart India
Tel: +49 (0) 7144 8990 | [email protected] Head Office Chennai | Tel: +91 (0) 44 4380 0201

Italy-Milano Ahmedabad | Tel: +91 794003 4272

Tel: +39 (0) 2268 22318 | [email protected] Mumbai | Tel: +91 22 4971 5883

France-Bordeaux New Delhi | Tel: +91 11 4165 4524

Tel: +33 (0) 5594 01050 | [email protected] Sales Network


in Kolkata, Bengaluru, Pune, Coimbatore,
Turkey-Istanbul
Hyderabad, Vadodara, Jaipur
Tel: +90 (216) 706 17 89 | [email protected]
Email: [email protected]
South Korea-Seoul
Tel: +82 (0) 10 7428 5732 | [email protected]

Hong Kong SAR For other country distributors,


International Export Office contact the Hong Kong office.

Tel: +852 2751 6080 Inovance Technology Companies


Shenzhen Inovance Technology Co. Ltd.
[email protected] Suzhou Inovance Technology Co. Ltd. www.inovance.eu

Copyright 2022 © Inovance Technology Co., Ltd., All rights reserved. The information contained in this brochure is for guidance only. Data code: 19120220 V0.0

You might also like