You are on page 1/ 2

Fire Situation

In situations where the battery is on fire, if it is safe to do so, disconnect the battery pack by turning of the
circuit breaker to shut off the power to the system. Use FM-200 or Co2 fire extinguisher for the battery
and an ABC fire extinguisher for the other parts of the system.
Under any fire situation, please evacuate the people from the building immediately before trying to
extinguish it.
Water Situation
The battery modules are not water resistant. Hence care should be taken not to get it wet. If you find the
battery completely or partially submerged in water do not try to open. Contact an authorized personnel or
Fox for further instructions.

5. Product Information
1. Mira-HV25 is a battery module, it needs to be used with Mira-BMS controller;
2. Mira-BMS is the controller of the whole system, so each system must have one Mira-BMS;
3. Our system consists of at least 2 Mira-HV25 + 1 Mira-BMS and up to 8 Mira-HV25 + 1 Mira-BMS.

5.1 Battery Module Specifications


Specifications for Mira-HV25
Battery module Mira-HV25
Nominal capacity (kWh) 2.45
Maximum charge voltage (V) 58.8
Discharge cut voltage (V) 46.4
Max. charge/discharge current (A) 48A/48A
Operating temperature (°C) -10 ~ 55
Storage temperature (°C) -10 ~35
Charge/Discharge efficiency (%) >95
Ingress protection IP21
Protective class I
Cycle life >4000 @25°C @80% SOH
Available SOC range 3%~100%
Weight (kg) 30.2±1 kg
Dimensions (L*W*H) (mm) 440*420*122

5.2 Mira-BMS Specifications

Specifications for Mira-BMS


Model NO. Mira-BMS
Operating voltage range(V) 86.4-500VDC
Max. charge/discharge current (A) 48A/48A
Total voltage measurement accuracy ±1.0%FSR
Total voltage measurement channel 4
Current measurement range -100A~+100A
Communication interfaces CAN
Available SOC range 3%~100%
Charge/Discharge efficiency (%) >95
Operating temperature (°C) -10 ~ 55
Storage temperature (°C) -10 ~35
Humidity 5%~95%
Weight (kg) 6.5±1 kg
Dimensions (L*W*H) (mm) 440*420*122

3
5.3 Battery System Specifications

Specifications for Battery System


The number of 2*Mira- 3*Mira- 4*Mira- 5* Mira- 6*Mira- 7* Mira- 8* Mira-
batteries HV25 HV25 HV25 HV25 HV25 HV25 HV25
Normal
102.4 153.6 204.8 256 307.2 358.4 409.6
voltage(V)
Normal capacity
48 48 48 48 48 48 48
(Ah)
Voltage range(V) 92.8-117.6 139.2-176.6 185.6-235.5 232.0-294.4 278.4-353.2 324.8-412.1 371.2-471.0
Recommended
charging 24
current(A)
Max.
charge/discharge 48
current (A)
CC-CV charging
3
cut-off current(A)
Peak charge
60
current(A)(30s)
Peak discharge
60
current(A)
Operating Charge: 0°C ~55°C
temperature (°C) Discharge: -10°C ~55°C
Storage
-10°C ~35°C
temperature (°C)
Cycle life ≥4000 @25°C @ 80%SOH
Ingress
IP21
protection
Protective class I
Communication
CAN
interfaces
Altitude [m] <2000
Pollution degree PD2
66.7±1kg 94.8±1kg 123.0±1kg 151.1±1kg 179.2±1kg 207.3±1kg 235.5±1kg
(Net) (Net) (Net) (Net) (Net) (Net) (Net)
Weight (kg)
73.5±1kg 104.1±1 kg 134.6±1 kg 165.1±1kg 195.7±1 kg 226.2±1 kg 256.7±1 kg
(Gross) (Gross) (Gross) (Gross) (Gross) (Gross) (Gross)