0% found this document useful (0 votes)
110 views1 page

Steel Map Description For House Construction Example, Civil Engineering

steel map description for house construction example, civil engineering

Uploaded by

karan007kurre
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views1 page

Steel Map Description For House Construction Example, Civil Engineering

steel map description for house construction example, civil engineering

Uploaded by

karan007kurre
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

COLUMN SCHEDULE

STRIPPING TIME TABLE

S.NO. COLUMN MARK COLUMN SIZE COLUMN REINF. STIRRUPS COLUMN SEC. TYPE OF FORMWORK MINIMUM TIME
BEFORE STRIKING
FORMWORK
14" 1. VERTICAL FORMWORK TO COLUMNS, 16-24 HRS.
4 - #16 DIA 8 @ 6" C/C
WALLS, BEAMS.
1 C-1 8" x 16"

8"
4 - #12 2. SOFFIT FORMWORK TO SLABS
(PROPS TO BE REFIXED
3 DAYS

IMMEDIATELY AFTER REMOVAL OF


12" FORMWORK)

1 C-2 8" x 12" 6 - #12 DIA 8 @ 6" C/C

8"
3. SOFFIT FORMWORK TO BEAMS 7 DAYS
(PROPS TO BE REFIXED
IMMEDIATELY AFTER REMOVAL OF
FORMWORK)

4. PROPS TO SLAB :

FOOTING SCHEDULE a) SPANNING UPTO 4.5 M


b) SPANNING OVER 4.5 M
7 DAYS
14 DAYS

5. PROPS TO BEAMS AND ARCHES :


a) SPANNING UPTO 6.0 M 14 DAYS

S.NO. FOOTING EXAVATION FOOTING DEPTH REINFORCEMENT b) SPANNING OVER 6.0 M 21 DAYS

SIZE
NOTES : -

#10@6"C/C BOTH GENERAL NOTES AS PER IS 456-2000

1 F-1 6'0" X 6'0" 5'0" X5'0" 18" 1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE NOTED
WAY 2.
3.
ONLY WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
P.C.C. (1:5:10).
4. CONCRETE MIX= M-20 (1:1.5:3).
#10@6"C/C BOTH 5.
6.
H.Y.S.D. TOR STEEL BARS SHOULD BE USED.
CONCRETE CLEAR COVER TO MAIN RFT. SHALL BE
2 F-2 7'0" X 4'6" 6'0" X4'0" 18" AS FOLLOWS :-

WAY COLUMNS = 40 mm ALL SIDES.


FOOTING = 50mm AT BOTTOM & SIDES.
BEAMS = 25mm AT TOP, BOTTOM & SIDES.
SLAB =15 mm AT TOP & BOTTOM.
#10@6"C/C BOTH 7. OVERLAP IN COLUMNS IS TO BE PROVIDED AT THE

3 F-3 5'6" X 5'6" 5'0" X5'0" 18"


MID HEIGHT OF COLUMN WITH STAGGER IN THE
MAIN BAR.
WAY 8. OVERLAP IN TOP BEAM BARS IS TO BE PROVIDED
NEAR TO THE MID SPAN IN A STAGGERED MANNER.
9. OVERLAP IN BOTTOM BEAM BARS IS TO BE
PROVIDED NEAR THE SUPPORTS IN A STAGGERED
#10@6"C/C BOTH MANNER.
4 F-4 11'6" X 4'6" 11'0" X4'0" 18" 10. ALL DIMENSIONS ARE TO BE CHECKED WITH
ARCHITECTURAL DRAWINGS FOR LAYOUT PURPOSE.
WAY
#10@6"C/C BOTH DRG TITLE
5 F-5 as per drg mesarment 18"
WAY FOUNDATION LAYOUT PLAN

CLIENT

MR.KURRE JI AT
PUNDAR
ORIENTATION
DATE
12-02-2024 W

N
S

EXTRA TIES AT THE POINT

SLOPE 1:6 MAX


OF BENT @ 3" - 3NOS.
PLOT NO.

DRAWN BY CHECKED BY
MAIN BAR
TYPICAL LAP DETAIL IN COLUMNS DEWANGAN
6"

TIES

1 1' #10@6"C/C
Y

16" 16"
D
d

B D M CONSULTANT
ARCHITECTS , ENGINEERS & INTERIORS
SHOP NO . - 15a, progressive point

PCC (M-10) (REIN. BOTHWAYS)


lalpur RAIPUR (C.G.)492001
EMAIL- [email protected]
6" X 6" 9826137104/9981169119/9827162272
6"

TYPICAL FOOTING SECTION (I-I')