Autometers Alliance Ltd [UM-CLK- Rev.
00]
1|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
Contents
Functional Description ............................................................................................................... 3
1. Overview: ........................................................................................................................ 3
2. Working principle: .............................................................................................................. 4
3. Technical Details: .............................................................................................................. 5
4. Wiring Diagram ................................................................................................................. 7
5. Manual configuration .......................................................................................................... 8
5.1 Setting the local current time in standalone model: ................................................................... 9
5.2 Controlling the brightness level of the clock: ......................................................................... 10
DIMENSIONS OF DIGITAL CLOCKS AND MOUNTING ARRANGEMENTS ............................. 11
Indoor Digital Clock .......................................................................................................... 12
Outdoor Digital Clock........................................................................................................ 13
IMPORTANT SAFETY INSTRUCTIONS .............................................................................. 14
NOTICE OF SAFETY SIGNS ON THE PRODUCT ................................................................ 15
2|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
Functional Description
1. Overview:
Indoor digital clocks are wall mounted, LED type, single faced and shall be
used in offices, equipment and plant rooms. The character height of the
display is 65mm.
Outdoor digital clocks are Single face, LED type and shall be used at head
end and tail end of each platform for the use of the train driver and
commuters. The character height of the display is 210mm.
Digital indoor clocks shall receive time synchronization from sub master
clock LEDI NETWORK TS via AFNOR NFS 87500 time code, 2 wire
AWG24 cable, no polarity.
In case of synchronization failure, it will run on its internal quartz time base
to maintain time accuracy 0.1 sec / 24h (20° to 30°C).
3|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
2. Working principle:
Figure: Block Diagram of Digital Clock
4|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
3. Technical Details:
Indoor Digital Clock:
Dimensions : 350 x 160 (case)
Height of digit : 65mm
Distance of legibility : 30 m
LED color : Red
Synchronization input : IRIG-B/AFNOR NFS 87500
Power supply : 230 VAC
Mounting : Wall Mount, bracket support included
Protection class : IP54
Color of case : Aluminum lacquered Black
Operating temperature : -20°C to 70°C
Storage temperature : -20°C to 80°C
Note: The product contains a non-replaceable lithium battery.
5|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
Outdoor Digital Clock:
Dimensions : 990 x 480 x 85mm
Height of digit : 210mm
Distance of legibility : 60 m
LED color : Red
Synchronization input : IRIG-B/AFNOR NFS 87500
Power supply : 230 VAC
Mounting : Ceiling mount
Protection class : IP65
Color of case : Aluminum lacquered Black
Operating temperature : -20°C to 70°C
Storage temperature : -20°C to 80°C
Note: The product contains a non-replaceable lithium battery.
6|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
4. Wiring Diagram
7|Page
Autometers Alliance Ltd [UM-CLK- Rev.00]
5. Manual configuration
The clock has provision to be manual configured using push buttons
option.
3 push buttons are provided in the product for manual configuration. Below
are the functions and operations to be done using key button:
► All settings are made using the 3 buttons ‘+’, ‘-’
and ‘PROG’ at the back of the product.
► To exit a menu, just hold down the ‘PROG’,
button or leave the buttons inactive for more than
70 seconds.
► Adjust the display brightness by pressing the
buttons ‘+’ and ‘-’.
8|Page
Autometers Alliance Ltd [UM-CLK-I2
5.1 Setting the local current time in standalone model:
Press the PROG key. The hour digit will start to blink as an
indication of the field being selected.
Set the current local time using + key for incrementing the
value and – for decrementing the value.
Press PROG key for switching to Minute digits. Now
minutes digits will start to blink.
Set the minutes as per current time using + and – key done
for hour setting.
Press PROG key for saving the configured time on internal
time source.
Autometers Alliance Ltd [UM-CLK- Rev.00]
5.2 Controlling the brightness level of the clock:
Press “+” key to increase the brightness level or press “–”
to decrease the brightness level. The selected value will
automatically will be saved.
10 | P a g e
Autometers Alliance Ltd [UM-CLK- Rev.00]
DIMENSIONS OF DIGITAL CLOCKS
AND
MOUNTING ARRANGEMENTS
11 | P a g e
Autometers Alliance Ltd [UM-CLK- Rev.00]
Indoor Digital Clock
12 | P a g e
Autometers Alliance Ltd [UM-CLK- Rev.00]
Outdoor Digital Clock
13 | P a g e
Autometers Alliance Ltd [UM-CLK- Rev.00]
IMPORTANT SAFETY INSTRUCTIONS
WARNING! Read the section that follows very carefully
before installing your equipment. It gives the safety
instructions to follow during installation.
The electrical installation to which the equipment is
connected must comply with the NFC 15-100 standard.
This device does not have a primary power switch. A
power protection system (circuit-breaker or
disconnecting switch), that is easy to access must be
built into the wiring installation. This device must
support the nominal voltage and current values
specified on the clock.
Modifying or opening the product without the consent of
the Customer service department will void the warranty.
All maintenance operation shall be conducted with
power shut off, including systems connected on relay
outputs if any.
Generally, the power cable (220V) and transmission
cable (of time signal) shall not be very close to each
other, so as to avoid interference (keep the distance of
a few centimeters)
14 | P a g e
Autometers Alliance Ltd [UM-CLK- Rev.00]
NOTICE OF SAFETY SIGNS ON THE PRODUCT
Danger – risk of damage to equipment if the
instructions are not followed.
Electrical Hazard – Failure to follow the
instructions may result in electric shock and
injury to persons.
The equipment is completed protected
through double insulation.
Warning
Follow the precautions and instructions as
indicated below in order to ensure your safety
and that of your environment, and to prevent
your device from any possible damage.
Warning: a switch-isolator compliant with
EN60947 standards is used as disconnect
device. it must be easily accessible and be
installed close to the power. it shall disconnect
all active polarities.
The Product is intended for use indoors only,
at an altitude below 2000 meters.
15 | P a g e
Autometers Alliance Ltd [UM-CLK- Rev.00]
ENGLISH
C-63, Sector-57, Noida-201 307, U.P. (India)
Ph.: 0120-2479200, 2583545~46; Fax: 0120-2583542
E-mail:
[email protected]; Web site: www.autometers.com
16 | P a g e