0% found this document useful (0 votes)
243 views17 pages

Spa Chair Instruction Small

Lux spa chair

Uploaded by

stagetwo2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
243 views17 pages

Spa Chair Instruction Small

Lux spa chair

Uploaded by

stagetwo2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 17
ee TABLE OF CONTENTS SECTION 1 SAFETY & PRECAUTION... SECTION 2 IDENTIFY YOUR FOOT SPA... seongcenvense Page E SECTION 3 FOOT-SPA CLEARANCE... Page 7 SECTION 4 INSTALLATIONS... SECTION 5 OPERATIONS & US! SECTION 6 CLEANING & MAINTENANCE ... SECTION 7 WARRANTY & SERVICE......-.00csssnenene SAFETY & PRECAUTION ‘Thank you forthe purchase ofthe LUXE spa of Spa Tech LLC. Please caretly read al the instructions in por intaling the spa. Especially please pay additional attenton on fhe sated precaution and waming statements. Tis puke eb ermpond oalnweh al oui pecoy = Cees Grong Poll Chout marge (OF onde FCI ust bo od opty A {ecard pcacion end conor operat. If te GFCl osba i poker ZX sonor use ths meoDUcT Beas cons steaeos nesron or ietlelono a Cas GFCl arsed ea oscita ote or oq ‘THIS PRODUCT IS FOR INDOOR USE ONLY. DISCONNECT POWER SUPPLY CORD BEFORE SERVICING AND CLEANING. ‘lecrican in aocordance with local codes. Plumbing and Electrcalinstalaions Ist be achired 0 inorder forthe waranty tobe in etfect ant insure the waswone_ utmost n safety. Chair and Spa Basin have a manimum seating capacty of 250 pounds [tis required trat fis Foot Spa being instaled by a licensed plumber and (/ THE BASIC PRECAUTIONS NUST ALWAYS BE OBSERVED: 4, Read and folow closely allinsiucions. 2. Dono let chidren use this uni unless they ee supervised tal times, ‘3, Use this unit onl for itsintended use as described in this manual. Do not use ‘attachments not recommended by manufacturer "Never drop or insert any objec int opening. {Dono block jts curing whitpoo! operation, ‘The unit must connected to an electrical supaly coat tats protectes by a GFCI ‘The clean jetmctor's magnetically driven and Insulated twice; therefore, It does not ‘equi to be bonded, PLEASE SAVE THESE INSTRUCTIONS, ) NOTE: Keep the spe ub dry and clean atl times afer servng each custome. Referothe Sate Boers sentation equeors applied on pedicure spa, & 1. Use SOFT SPONGE to clean glass bow! for avoiding surface seratches, 2 Excessive water temperature is dangerous and should be checked before use. 3 Maximum water temperature should never exceed 90 degrees F o: warmievel._ 4, Always enter and exit the Foot Spa slowly and carefully. 5. Never operate any electrical devices into or near the Foot Spa, 6, Allof these components must be factory installed: Jet, drain pump, massage cher, ed igh Thi produ h whole sin compliance wi the applikabe UL LISTED standard, issued by Underwriters Laboratories Inc., Page 4 IDENTIFY YOUR FOOT SPA WATER FILLER HEADREST CUSHION BACK CUSHION & MASSAGE WATER CONTROL DRAIN PUMP CONTROL IDENTIFY YOUR FOOT SPA (Cont’d) 2, Reclining Back Cushion for more comfort. |. Armrest can be swang up and down easy access, 56" FOOT SPA CLEARANCE —————— — = @ SPACING oan — > 16.00" ~— 28.00" 16.00" =— ‘SEAT INSTALLATION 1. Attach tray or remote stand to armrest (hardwares provided) 2. Align seat withthe pre-driled holes on the base then install hardwares as shown in the illustration beiow). Proceed ta secure ruts and bolt tightly BOLT (ALLEN) FLAT WASHER (2) Page 8 WHIRPOOL JET INSTALLATION @ PURE JET INSTALLATION Ups (4) FIBERGLASS BOWL 4. NOTE: To avoid water leakage, itis ‘essential to align lips from electric motor perfectly with sets on housing 2. When instaling motor, frst apply moderate pressure to motor to engage moto ips (4) with housing slots (4), then twist mator conterclockwise untl secured. Page 9 WHIRPOOL JET INSTALLATION (Cont'd) | @ MAGNAJET 500 INSTALLATION FIBER “ BOWL RUBBER SEAL “T WoTOR sei Poae 10 PLUMBING CONNECTIONS 1. Discharge pump may be connected to an existing sink drain or ‘cor drain. t can also pump up to 7 fthigh, but this wil increase the length of the drain time. The drain connection is at the rear of unit by @ 1/2 fitting. 2, Graviy drain uses a standard gravity dei, A floor drain i recommended. Connection via a P-Trap is supplied, 33. Hot and Cold water supply connections are located a: ‘he rear of the unit (1/2 inch fitting). Please be advised that the hot and cold water supply lines are not fitted wih optional Back Flow Preventers unless ordered atiniial sale, ‘Water Connections: @ GRAVITY DRAIN 14/4" PVC PeTrap 11/4" PVC i (5.00” LONG) PLUMBING CONNECTIONS (Cont'd) @ POWER DRAIN AIR SWITCH TUBING — 36.00" 4. Have a qualtied licensee electrician to install the witing according to local codes. The clean jets are 1/10hp, 120V, 1.2 AMP 600 HZ. A15 AMP GFl protected circuit must ‘to supply power to the unit. The rol er back massage chair uses an 1 15V supply. 5. Spa base should be enchored securely to the floor. The base mayve anchored through ‘the opening in the back of the base wherever access is convenience for the installer. FAILURE TO ANCHOR THE BASE MAY RESULT IN PERSONAL INJURY OR DAMAGE OF THE UNIT. DAMAGE AS A RESULT WILL VOID THE WARRANTY. Paae 12 SPECIFICATIONS CHAIR sPEciFicATIONS Massage Rotot:? Moto! 4 Roler Massage Operating Volage: 115 V Electrical Input Ratings (Whole Spa Uni): 120 VAC, 6.0, 60 Hz (GFCI Protected) ‘Macimam Weight Capacity: 250 Lbs Maximum Water Terperatire: 40 Degree C (104 Degree F) Wepht: Chair220 Lbs Shipping Weight Chai -270 lbs Foct Spa Cleararce for Recining / Slicing Operation: Refer to Page 6 & 7 for dimensions Six(6) Massage Functions; Press, Kneading, Flapping, Percussion, Knocking, Kneading & Flapping Massage Head Storage: Auto stop at op ‘Automatic Timer Shuf-Of: 15 minutes Note: Due to our poly of continuous improvements, al specications are subject fo change wthcut notice Also, all dimensions and wegh's ate approximate BASIN sPEciFicATiONs Hotand cold water inet supply lines are using 0.5" diameter fittings Drainage: Refer to pege 11 & 12; bul with dain pump for wal drain ora gravity dran for oor dran Empty weight: 120 lbs Shipping weight 170 Ibs Capacity of basin: 5 US Gallons Chromo therapy Light 120V, 60 Hz, 21W with Class 2 PS: Input: 120V, BOM. 2“W: Output 12Vae, 00mA, Motorized, Massaging Chair: 120V, 60 Hz, 2.04, 180W witha hanc-held low voltage remote controler. Drain Pump Motor: 120, 60 Hz. 1.44, 851 Whitpcol Jet System: 120V, 60 Hz, 1.28, 30W One On/Off air switch for Whiripool Jet & Led Light, One On'Of lr switch for Orain Pump "Note: Due o ou policy of cont uous improvements al specifications are subject to change without ratice Caton: Pedicure spa mustbe installed by a Icensed elecirclan and 2 licensed plumber, conforming to al ‘bce! and national electrical codes. Also, the spa basin shoul be anchored securely o the foor Page 13 OPERATION AND USE (Cont'd) ("BASIC PRECAUTION SHOULD ALWAYS BE OBSERVED, INCLUDING THE | FoLLowine: 4. Read and follow ail instructions, | 2. DANGER, To reduce the risk of injury, do not allow children to use this unit | unless they are supervised at all times. | 3. Use this unit only for its imended use as described in this manval. Do not use attachments that are not recommended by manufacturer. 4. Never drop or insert any object into opening. 5. Do not block jets during whirlpoot operation, 6. The unit must be connected to an electrical supply circuit that is protected bya GFC. 7.The dean jet rotors magnetically driven and insulated twice. Therefore it does not require to be bonded | PLEASE SAVE THESE INSTRUCTIONS. @ SHIATSU REMOTE CONTROL OPERATION AND USE (Cont'd) | @ SHIATSU REMOTE CONTROL [ MASSAGE BALLS ADJUSTMENT | Jo tart or sop message ofthe uper body The button does nc werk wen the massage system is ats peston of recovery | Thee tining odes: 19 mins,20-mirs, 30 mins. i | | Adopt the varias tats tp carry on automatic | } cilerent poston a a | Srebod thy maceageportion coer he tncke | __||_ubper part the tee J To caring on autematc massage arourd the neck | shoulder many | ‘carrying on automatic massage around in| wc | | Gorynginewast ray | as DISPLAY STATUS MASSAGEBALIS ADJUSTMENT | — SS we l We ‘Speed, With, Strength | | i ee Ne eel a —-+ | vero |! vy Speed.Stengh a IL wee iI | ®) || Speed, With, Strength | f i 1 foes | | Sy Spee, Strength | © Speed, Wie, Srenath I | Page 15 CLEANING & MAINTENANCE | Please refer to the diagrams to remove jest covers for cleaning. ‘Spa Tech LLC. highly rechmmen the floving cleaning reginen You should alvayscottact your local governing agency fr their specfc Gearing and dsinfecirg requirements and regulations for pedicure spas. For your dients safely always Lse the requations as a minimum stardad for Cleaning and dsrtectnc| Combining your sates standards wih the regimen listed below wil provide your cients wth 2 safe reathy pedicure spa enironment expecence. ‘ROUTINE MAINTENANCE Powdered cleansers or abrasives at NOT RECOMMENDED A cnn towel or sponge ae a that Usvaly needed. A soft brstled brush my be used when excessive residue I present. Use a mid soap and wattr solution fo Ceanthe upholstery but donot over et Wipe cry vith a clean towel Nointernal maintenance ofthe spa components is necessary Remove lean jest caps ay spray with snfectant tier each use. For extra protectin, our recommendation shat the system be flushed daly or weekY depend on using To ush the Can jet system, fsa with hot water t just above thejests. Add disnfecant. Run wirpoo for 15 mirutes, drain an then wipe dry wth clean sot doth RECOMMENDATION: Keep the spa tub dry and clean at ll times after serving each customer, Refer to State Boards sartation regulations required on pedicure sta. Note Cleaning or sanitizing is NOT disinfecing According to the Ceniers for Disease Central and reversion (COC), ar the US Eniomental Protection Ageny (EPA), disinfecting oxzurs only hen theres 2 reducion of pathogenic microbes at 99.99 °. Saifzing is onk a reduction of 92.9%. Geaning of whirioal pedicure soas reales surfactant ard chelating that are low-foaming and have abit to remove body cls, organic ol addtives,nnefal ss, skin cels, nal dipping, ete, that can accumulate bath in the basin and the jets which may become a fertle aes for microorgarisms to gr | ‘The use of oll based products can build up the whirpoel system causing dogging inthe ets. ‘Adherence tothe above cleaning wil miniize the bud. Spa Tech LL doesnot recommend the use ‘of mineral ol based products, ‘TESTING/FLUSHING FOOT SPA ‘Aer foot spa has been stale, fl tub wit water just above the jets. Carefly check freaks at drain and over flow. Aftet checking underside for leaks, turn on system by pushing whirlpool button and watch for leaks 2s water crulates. Let tu ru ful cycle, Open crain for waler discharge. Pane 16 WARRANTY & SERVICE ‘Spa Tesh LC, warrarts to the ofgiral purchaser tht the new pedicure spa willbe free rom detect ‘durng the Standare Warranty Petod (sted be'on), The stipping date ad the uniquey-coded Seral Numberon he back of each spa cha wil us the start othe waranty perad for he roduc. The warranty snl and vod the spa is aker from ts laa place of Installation, ort 8 not instal n accordance wth federal, state oc ocl codes and orirarces ls, this warranty does not appl If the pecs Spa has been subject to mesappication, imprope™ instalation or Imahterance, regigerce, improper deaning o other ccustances beyond Spa Tech's contro, WARRANTY. 4 Lined One (1 Yeas waranty en Spa Shed 2 Lined One (1) Year wairarty cn he Wilpon pump, 3. Lites One (1) Year warraty onthe Pre lt. 4, Lied One (1) Year warranty on the Fiber Gio Bow, 5. Limited One (t) Year Parts-Only warranty which covers the Hdrauie Sytem, Dacharge Pump. Massage Syster\and all Electrical Components, 6. Linted 0 day of abor 7. Spa Tech LLC, pays thipoing charges on al replacement parte during the fist 90 days of the ‘tated Warranty Perc! Aer 90 days, the ccesumer's responsbe for al abo and ebpping T 1. Damage to pump paits andlor motor parts due to obstruction in plumbing ine, ete 2 Staining, fang or of asic urfaces due to exposure andlor he use of harafl ee 3 Stang, fang orc caused by improper or poor water adves not relate tothe Irantenance of prope: water are nt covered by this warranty 4 Stlnng, Fading or dscciortion of Set, armrests or coves, 5. Freight damage, msise,neglec, accident, natural dssster and abuse. 6 Unauthorized frais. 41. The Deal shal oryard al warrany-eated matters tour Customer Service Department. 2 Serial Numbers and DriginalInsice must scompary al warranty clams. 3. Customers are responsible or shipping defective paris beck to Spa Tech These parts must be (packaged correct in arder to protect against any further damage, 4 Apart are to be shipped by UPS Grout Service average 2-5 cays 5. Algefectve parts mist be shipped back te Spa Tech within 30 days of receving the new ‘replacement parts oc warranty wi be void. 6 Any warrany clam hat cannot be Getemineé over the phone, customer must send photos sd orignal mvcice directly to Spa Tech belore ary repars canbe performed. | Paae 17 WARRANTY & SERVICE (Cont’d)) © SERVICE (Conta) 2, Any service performed in the product without Spa Tech authorization wil algo vod the warrandy. 8 Each sere cal rom the custome wl ie assigned a Gaim Nbr. The Chim Nunber wi tay json ole sched | No desler o other person has any authori to bind Spx Tech LC, to changes or auditions to this warranty o its products. Accordingly, Spa Tech LLC, isnot | responsible for such warranties or representations. i ‘TECHNICAL SUPPORT 11081 Westminster Ave, Garden Grove, CA 92843, Tel: 1-800-866-6377, Fax, 714-584-1506 ‘obs: want. spateteorp.com Page 18

You might also like