You are on page 1/ 6

D-LUX

Version: 1204

INDEX
Page 1 General safety instructions
Page 2 Installation instructions (part 1 of 3)
Page 3 Installation instructions (part 2 of 3)
Page 4 Installation instructions (part 3 of 3)
Page 5 General drain description and installation/maintenance notes and specifications
Page 6 Service chart

SAFETY and PROPER USAGE


To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed herein. Non-compliance
with instructions or improper handling of the product will void your warranty! This product is designed for use exclusively with types of
fluids or gasses as stated in its documentation. Usage of this product in conditions not specified in the product documentation or contrary to
the instructions hereby provided is considered IMPROPER. The manufacturer will not be held liable for any damages resulting from
improper use of the product.

ATTENTION
- Observe valid and generally accepted safety rules when planning, installing and using this product.
- Take proper measures to prevent unintentional operation of the product or damage to it.
- Do not attempt to disassemble this product or lines in the system while they are under pressure.
- Always turn off the voltage supply before working on the system.

It is important that personnel use safe working practices and observe all regulations and legal requirements for safety when operating this
product. When handling, operating or carrying out maintenance on this product, personnel must employ safe engineering practices and
observe all local health & safety requirements & regulations. International users refer to regulations that prevail within the country of
installation. Most accidents which occur during the operation and maintenance of machinery are the result of failure to observe basic safety
rules or precautions. An accident can often be avoided by recognising a situation that is potentially dangerous. Improper operation or
maintenance of this product could be dangerous and result in an accident causing injury or death. The manufacturer cannot anticipate every
possible circumstance which may represent a potential hazard. The WARNINGS in this manual cover the most common potential hazards
and are therefore not all- inclusive. If the user employs an operating procedure, an item of equipment or a method of working which is not
specifically recommended by the manufacturer he must ensure that the product will not be damaged or made unsafe and that there is no risk
to persons or property.
PLEASE NOTE: YOUR WARRANTY WILL BE INVALIDATED IF THE EQUIPMENT HAS NOT BEEN INSTALLED OR
MAINTAINED IN ACCORDANCE WITH THESE INSTRUCTIONS.

SAFETY

Switch off the voltage supply before Depressurise the system before installation or
installation or maintenance is carried out! maintenance is carried out!

1
INSTALLATION INSTRUCTIONS (part 1 of 3)

IMPORTANT NOTICE

Before installing this product make sure


it complies with your request and
that it suits your application!
Unpack the unit and visually inspect for
any transport damage incurred after
leaving our factory

Flat gasket gasket B Screw

Install the solenoid valve according to the


general safe engineering practices and
Remover the connector and timer observe all local health & safety requirements
from the solenoid valve & regulations

Remove the protection cap from the connector


and connect your power cable as shown
Connect the D-Lux timer back on to
the coil as illustrated and
make sure the flat gasket is securly in place

2
INSTALLATION INSTRUCTIONS (part 2 of 3)

Switch ON the power.


Note: the voltage must comply with the
Connect the DIN connector back on to voltage mentioned on the coil.
the D-Lux timer as illustrated and
make sure the gasket B is securly in place
and tighten the screw (max. 1Nm)
The unit will be IP65 when propperly installed.

The D-Lux will start with its pre-set time


setting of 10 sec ON and 30 sec OFF. When the unit is installed correctly and
The display will start counting down the ON operational, you can change the pre-set values
time (10, 9, 8, etc.) and the SEC led will be to anything ranging from 0.1 sec to 99 hrs.
flashing. When the ON time reached 0 sec it To change the ON time simply press the right
will jump to the OFF time and start counting ‘on/arrow up’ button and ‘on’will appear
down the OFF time (30, 29, etc.) briefly on the display.

If the desired ON time is set, then simply


don’t press any buttons and after a few
seconds the display will start flashing
The previously set ON time will appear on the illustrating that the new time is being saved.
display (10) and the sec led will be on.
You can now press the left ‘off/arrow down‘ Once the new time is saved, the unit will start
button for decreasing the time or the right operating with the new time setting.
‘on/arrow up’ button to increase the time.
The sec, min of hrs led will highlight the time
bracket (i.e 1-99 sec or 1-99 min or 1-99 hrs)

3
INSTALLATION INSTRUCTIONS (part 3 of 3)

The previuosly set OFF time will appear on


the display (30) and the sec led will be on.
You can now press the left ‘off/arrow down‘
button for decreasing the time or the right
To change the OFF time simply press the left ‘on/arrow up’ button to increase the time.
‘off/arrow down’ button and ‘of’will appear The sec, min of hrs led will highlight the time
briefly on the display. bracket (i.e 1-99 sec or 1-99 min or 1-99 hrs)

If the desired OFF time is set, then simply


The unit is now fully programmed
don’t press any buttons and after a few
seconds the display will start flashing
to your desired time settings and
illustrating that the new time is being saved.
will work fully automatically.
Once the new time is saved, the unit will start
operating with the new time setting.

After releasing the test button

the unit will resume normal operation.

You can press the TEST button anytime to


check the valve operation or to manually
activate the valve to discharge any
condensate. When the test (middle) button is
pressed a flowing pattern is diplayed
indicating the test function is in process.

4
DESCRIPTION OF NORMAL OPERATION
The function of the electronic drain valve is to drain condensate from air compressors, air dryers, condensate separators and air filters.

OPERATING THE DRAIN


⇒ Ensure drain is installed in accordance with this manual.
⇒ Switch on power supply. The ON LED will indicate that the valve is OPEN.
⇒ Ensure air pressure is between minimum 0 bar g (0 psi g) and maximum 16 bar g (230 psi g).
⇒ Test solenoid valve operation by pressing the test button.
⇒ Set the required ON time and OFF time.
⇒ Drain operation will now be fully automatic.

INSTALLATION NOTES
A. UNPACKING
Although the manufacturer takes every precaution with packaging, it is advisable after carefully removing the product from it's box and
packing material to carry out a thorough visual inspection for any sign of transit damage incurred after leaving our factory.

B. DIRECT CONNECTION TO THE COMPRESSED AIR SYSTEM OR PRESSURE VESSEL


· Make sure that no solid matter (e.g. sealing compound residue) gets into the unit during the installation.
· Make sure that the pipeline is thoroughly clean.
· Use quality sealing compound only!
· Use a proper tool for fixing the unit to your pipe work! Never use the unit as a lever.
. The unit can be mounted in any position (but recommended is upright).
. Ensure ALL outlet pipe work / fittings have a minimum internal diameter of 4.5 mm or greater.
. One drain is required for each pressure vessel being drained.
. Only use the correct threaded adapters.

C. POWER SUPPLY / ELECTRICAL CONNECTION


Power Supply
Please ensure voltage of drain model supplied correctly matches the supply voltage of the installation site. (Refer to the label on the coil).
The method of electrical connection and cable used should be appropriate for the regulations and conditions that prevail in the country of use.

BROWN = Neutral
BLUE = Phase
YELLOW/GREEN = Earth (Must be connected)

D. DISPOSAL OF CONDENSATE
Condensate produced by the compressed air system should be disposed of in a responsible manner and in accordance with laws and
regulations that prevail in the country of installation. We suggest you install a PURO Condensate Cleaner after each compressed air draining
point (please refer to the PURO Condensate Cleaner installation manuals for more details).

MAINTENANCE
Depressurise the unit (exhaust all compressed air from the unit) and s witch off electrical supply before carrying out any work
or maintenance on the unit!

- The electronic drain valve is maintenance free. However, we recommend replacing wearing valve parts every two years. You can
obtain service kits from your dealer. We also recommend you test the electronic drain valve every time the compressed air system
is checked, by pressing the TEST-switch on the timer.

TIMER TECHNICAL SPECIFICATIONS


Technical data Time r
Interval Time T2(1) 0.1 seconds – 99 hours
Discharge Time T1(1) 0.1 seconds – 99 hours
Manual Test Switch Yes
Supply Voltage (2) 115V - 240V± 10% 50/60Hz
Current Consumption Approx. 5.5 mA
Switching cuurent Max. 1 A
Operating Temperature -10°C to +50°C
Environmental Protection IP 65 NEMA 4
Case Material ABS Plastic FR Grade
Connection DIN 43650A ISO 4400/6952
Indicators Yellow, valve open (ON)
Yellow, time bracket indication (min, sec, hrs)

5
Service Chart:
DATE DESCRIPTION NAME/SIGNATURE REMARK