Product brochure 20–200 kW
Eaton 93PM 200 kW UPS
Efficient. Scalable. Innovative.
The Eaton® 93PM UPS combines efficiency and reliability Easy management
with an eye-catching design. A space-saving, scalable and
flexible device that’s as easy to deploy as it is to manage, • Track statistics on energy savings, battery time and
it’s the perfect three-phase white or grey space solution for outages profile your load and much more with the friendly
today’s data center. graphical LCD touchscreen interface
• View system status from a distance with the green/
Lowest TCO (total cost of ownership) yellow/red LED light bars
• Conserve valuable data center floor space with the
compact footprint, internal battery back-up and optional Advanced IT integration
internal maintenance bypass • Supports optional communication cards that allow remote
• Grow effortlessly with the vertical scalability, reducing cost access via the HTTP(S), SNMP, MODBUS TCP/IP, Modbus
and unexpected future growth risks RTU and BACnet IP protcols
• Reduce power and cooling OPEX through industry-leading • Manage your power devices in your physical or virtual
energy efficiency environment with Eaton’s Power Xpert® software and
Intelligent Power™ Software Suite
– 99 percent efficiency with Energy Saver System (ESS)
• Increase uptime through 24x7 remote monitoring and
– Up to 97 percent efficiency in double-conversion mode reporting capabilities using Eaton’s PredictPulse™ service
that alerts technicians during critical events and results in
Easy deployment faster resolutions when a problem is detected; learn more
• Provides flexible configurability, maximizing deployment at Eaton.com/PredictPulse
flexibility
Eaton 93PM ESS
100
efficiency in double- Double-conversion mode
conversion and ESS Legacy UPS
UPS efficiency (%)
90
80
Typical Operating Range
70
10 20 30 40 50 60 70 80 90 100
UPS load (%)
The 93PM ESS energy cost savings pay for the UPS in less
than 3 years. Calculate your 93PM savings with ESS at
Eaton.com/ESS.
The functional core B
of the 93PM UPS C A
A Top & bottom cable entry
Standard right-mounted wireway, supporting both
top and bottom cable entry. This section contains
E
all input and output connections for the UPS
B Communications and connectivity 74"H
• Built-in device and host USB
• Five alarm inputs and dedicated EPO
• Alarm relay output
• Four communication slots
F •9
9% ESS
C efficiency
Color touchscreen LCD interface
•9
7% double-
D Serviceable redundant fan assembly conversion
efficiency
E Swappable power modules (50 kW)
with independent control and power
F Soft start controls
G
G Static switch assembly
42"D
32"W
Open front view of the unit Front view
EATON 93PM UPS TECHNICAL SPECIFICATIONS1
Power modules for 200 kW frame Output
Power offering (kW) 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, Voltage 480V 3-phase 3-wire or 4-wire (208V with IAC-D)
130, 140, 150, 160, 170, 180, 190, 200 kW
with optional internal N+1 redundancy through Regulation ±1% steady state
150 kW Voltage THD <1% (100% linear load);
<5% (non-linear load)
General characteristics Load power factor range Unity with the ability to support 0.8 leading to
Efficiency in Energy Saver System (ESS) Up to 99% 0.8 lagging without de-rating
Efficiency in double-conversion mode Up to 97%
Certification
Parallel capability Four distributed
Safety UL 1778, UL 924 Auxiliary, cULus
Height x depth x width 74" x 42" x 32"
EMC FCC Part 15 subpart B class A
Input characteristics Surge IEC 61000-4-5
Voltage 480V 3-phase 3-wire or 4-wire (208V with IAC-D)
Optional accessories
Voltage range +10% / -15% •
Integrated slim maintenance bypass
Frequency range 50/60 Hz • Integrated distribution cabinet (with output transformer options)
• Integrated power distribution cabinet
Power factor > .99 • Integrated battery cabinet (small and large)
Input current distortion < 3% @ 100% load capacity
UL 924 certification
Battery
The 93PM meets the strict standards for UL 924 compliance for emergency lighting
Battery voltage 432V, 480V2 applications when ordered with an emergency lighting SKU.
Charging method ABM® or float technology For more information, visit Eaton.com/UL924UPS
Due to continued improvements, specifications are subject to change.
1
480V battery voltage required for 480V 4-wire UPS configuration.
2
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Learn more at: Eaton.com/93PM
© 2018 Eaton Eaton, ABM, Intelligent Power, Power Xpert and
All Rights Reserved PredictPulse are registered trademarks.
Printed in USA
BR153091EN / GG All other trademarks are property of their