FH21391NN
Filter/Separator
Installation Instructions
Parts List
Fleetguard® Cummins
K Part Part
L
Part Description Number Number
A* Spin-On Filter FS53051NN –
M
SAE 3/4" Plug with
B M14 Diagnostic Port Not Service Replaceable
and O-Ring Seal
N
SAE #12 Flare
Adapter (Standard
O C 3968203 S 4919995
SAE J514 or
A MIL-F-18866 Fitting)
Water-In-Fuel (WIF)
D 3960826 S 4919917
Sensor
M
Q E Bottom Seal 3970958 S 4919920
F Bottom Plate 3970959 S 4919921
G Drain Valve 3954131 S 4919916
J
L
H Bottom Bolts (6) 3946704 S 4919915
I* FH21391NN See page 3
J Lift Pump Inlet Hose SP1069 4919983
K Lift Pump Outlet Hose SP1070 –
90° Fittings and
L Not Service Replaceable
B O-Ring Seals
M Vibration Isolators 3946691 S 4919914
B Lift Pump Bracket
N Not Service Replaceable
and Bolts
C O Primer Pump 3946995 S 4919922
Primer Pump Fitting
I P 3961296 S 4919918
Set for Single Units
D Delta Pressure (DP)
P E Q Gauge Kit for Single 3966456 S 4919919
Body Units
* Order this part directly from Fleetguard.
F Note: Remove plug from water drain valve prior
to operation.
CAUTION: These instructions are intended for use by professional mechanics who are trained in the proper
use of power and hand tools, using appropriate safety precautions (including eye protection).
page 2
FH21391NN Installation
WARNING: When diesel fuel is circulated Fuel Supply to
Engine Fuel
through an operating engine, Pump
it can become very hot. To Transfer Pump
prevent personal injury:
Scalding hazard! Do not allow heated
Stage 0
liquid fuel to come in contact with eyes or
unprotected skin. Always allow the engine
and fuel to cool to ambient temperature
before replacing the fuel filter or performing Fuel Tank
service operations which could result in the
spillage of fuel from the fuel system. If this is Figure 1 - FH21391NN Connections
not possible, protective clothing (face shield, 4. Outlet check valves are included with Dual/
insulated hat, gloves, apron) must be worn. Duplex and Triple/Triplex systems. Check valves
Heated diesel fuel can form combustible must be used to maintain prime and prevent
vapor mixtures in the area around the fuel drainback. The outlet check valve is necessary
source. To eliminate the potential for fire, to prime the housing properly as it prevents the
keep open flames, sparks or other potential priming pump from pumping back into the unit.
ignition sources away from the work area, 5. To minimize restrictions, observe the following
and do not smoke during filter replacement guidelines when plumbing the system.
or service operations which could result in a. Keep the fuel line routing as smooth as
the escape of diesel fuel or fuel vapors. possible with no low hanging loops which
can trap water.
Always perform engine or vessel fuel system
maintenance in a well ventilated area that is b. Use 90° elbows only when necessary.
kept free of bystanders. c. If the fuel hoses are made up to length on
the job, be sure that the inner liner of the
Installation Steps fuel hose is not cut by the fitting, creating
1. Mount the FH21391NN in the desired location, potential check valve effects. Also make
keeping the following points in mind: sure hoses are clean and free of debris
before installing.
a. Mounting the FH21391NN directly on the
engine is NOT RECOMMENDED. 6. Apply Teflon® pipe sealant to the inlet and outlet
hose threads and connect the hoses to the unit.
b. Mount vertically with the filter pointing up.
Tighten to a maximum of 50-60 ft-lb (68-81 N·m).
c. Make sure there is enough top and side
clearance for the filter to be conveniently CAUTION: To avoid damaging the aluminum fuel
removed for replacement. housing, do not overtighten fuel lines
or fuel line fittings.
2. To change the side of the inlet/outlet connection:
a. Remove the fitting from the manifold. 7. Plug the Lift Pump and the WIF sensor electrical
b. Insert plug where the fitting was removed. connectors into the on-engine harness. The
connectors on the on-engine harness are labeled
c. Apply Teflon® pipe sealant to the fitting
as shown in Figure 2.
threads and install in the manifold in the new
location.
Water-In-Fuel
d. Tighten to a maximum of 40-45 ft-lb
(54-61 N·m).
p
3. Route the fuel supply line from the outlet of the
m
Pu
ft
Stage 0 filtration device to the FH21391NN inlet
Li
(see Figure 1). (If no Stage 0 filtration device
is present, route the fuel supply line from the Figure 2 – Wiring Harness Connectors
outlet of the fuel tank.) Route a fuel line from the
FH21391NN outlet to the fuel pump inlet.
page 3
Filter Change Procedure up, the filter is considered plugged and a filter
change must be performed.
To change the filter, refer to the correct Operation
and Maintenance manual for your engine type,
as shown below and use replacement filter Suggested Preventive Maintenance
FS53051NN, NanoNet® 5 Micron Spin-On Filter.
Daily:
Table 2 - Operation and Maintenance Manuals 1. Check DP gauge indicator.
2. Drain water from each filter housing.
Engine Family Manual Number
QSK19 MCRS 5579623 Every 12 Months - Check fuel fittings for leaks.
Delta Pressure (DP) Gauge
The Cummins Filtration® Delta Pressure (DP) gauge
measures the difference in pressure across the inlet
and outlet of the fuel housing (through the filter).
The indicator stem of the gauge pops up when there
is a pressure difference greater than 6-8 in Hg
(20-27 kPa). When the red indicator stem is popped
Ordering Information
Fuel Fuel In
Housing Filter Flow & Fuel Out
Part Filter Element Micron gal/hr Primer DP1 Fuel In & Fuel In & Fuel Out Port Size2
Number Type Element Type Rating1 (L/hr) Pump Gauge WIF Drain Fuel Out Port Size (metric)
SAE #12 (37° Flare,
FH21391NN Single FS53051NN Spin-On 53 200 (757) Yes Yes Yes Yes In Right/Out Left N/A
1-1/16"-12)
1
DP = Differential Pressure
2
Metric connections require metric adapter fittings. For M26 x 1.5 fittings, use part no. 3954136 S (which includes an outlet M26 x 1.5 outlet fitting, M26 x
1.5 inlet fitting with check valve body, check valve ball, check valve retainer, and check valve spring) and install to inlet and outlet ports of housing. For M42
x 2 fittings, use part no. 3956561 S (which contains two M42 x 2 fittings) and install to inlet and outlet ports of assembly.
3
For proper protection of the Cummins High Pressure Common Rail fuel system, it is absolutely vital that the 5 micron filter be used and that no other filter
micron rating is substituted.
page 4
FH21391NN Specifications WIF Specifications
Specification Single WIF
Height Overall 22.27" (566 mm) Specification 3960826 S
(4919917)
Depth Overall 7.24" (184 mm)
Resistance Across Pins 82 kΩ ±2% (at 25° C)
Width, max 11.98" (304 mm)
Voltage Rating 5 – 50 VDC or VAC
Mt. Brkt. Centers (Horiz.) 5.20" (132 mm)
Mt. Brkt. Centers (Vert.) 4.25" (108 mm) Signal Type Analog
Weight (Dry) 22 lbs (10 kg) Thread 1/2" 20 UNF-2A
Fuel Capacity (w/o filter) 0.71 gal (2.7 L) WIF Harness Deutsch
DT04-2P
Connector
Fuel Connections SAE #12 (37° Flare, 1-1/16"-12)
Height to Water Sensing
1.21" (30.73 mm)
Water Trap Capacity 11.0 fl oz (325 ml) (Switch is in ON Position)
Filter Service Clearance Min. 1.5" (38.1 mm) Overall Length (WIF Body) 1.94" (49.28 mm)
Compatible for use with Diesel #1, Diesel Distance Between Blades
Fuel Types 0.168" (4.27mm)
#2, Kerosene, Biodiesel, and JP8 (Center to Center)
Specifications subject to change without notice. Specifications subject to change without notice.
Primer Pump Specifications
Specification Primer Pump
Voltage 24 VDC ± 0.1
Connector Deutsch DT04-2P-E004
Flow 32 gal/min @ 44 lbs/in2 (121 L/min @ 3.0 bar)
Max Current Draw 6A
Max Pressure 90 lb/in2 (6.2 bar)
Max Air Leakage 1.5 cc/min @ 80 lb/in2(3.5 x 10-4 ft3/min @ 5.5 bar)
Min Dry Vacuum 10" Hg (33.69 kPa)
Temperature Range -20 °F (-29 °C) to 250 °F (120 °C)
Specifications subject to change without notice.