Hi-Ballast Trouble Shooting Manual (R13)
Hi-Ballast Trouble Shooting Manual (R13)
We appreciate your unwavering support and cooperation rendered to our Ballast Water
Treatment System businesses. We have revised the existing trouble shooting manual into
following 6 categories by adding system controller, ACONIS.
Elecrolysis Unit
Filter Unit
Neutralization Unit
TRO Sensor Unit
Rectifier
ACONIS
As you already know, whenever any alarm appears on the display monitor, you can just find the
same alarm tag in the Table of Alarm and turn to the corresponding page to follow the trouble
shooting instructions. We’ve also attached photos and diagrams at the later part of this booklet for
you reference and enhanced the table of contents so that you can easily find resolutions to your
problem.
If you have any suggestions, other useful information or you cannot clear the problem with this
trouble shooting manual, please don’t hesitate to contact us:
Head office
Centum Science Park, 79, Centum Jungang-ro,
Haeundae-gu, Busan 48058, Rep. of Korea
Tel +82 52 204 7600~1, Fax +82 52 204 7700
https://www.hyundai-gs.com
Thank you
How to Use This Manual (I)
1. When some alarms occur in alarm list on the Mimic(HMI), please find which alarm is
activated first by clicking th following [ALAM LIST] icon. The first alarm is important to find
what problem is.
2. Briefly the latest alarm TAG and Description will be shown in bottom side of the Mimic.
3. And look for the corresponding ALARM TAG in the TABLE OF ALARM of this manual.
② ③
- 5 -
4. Please note the information and the cause of the alarm and follow the instruction to fix it.
① 26 Page
③ ④
- 6 -
5. For detailed instrcurtion, please refer to the Trouble Shooting in the APPENDIX.
Appendix
- 7 -
How to Use This Manual (II)
1. Look for the corresponding cause of the trouble in the TABLE OF TROUBLE SHOOTING in
the APPENDIX.
Appendix
- 8 -
How to Communicate with HGS
1. When you have some problems, please check your HiBallast according to this manual at first
.
2. In case that our Trouble Shooting can’t resolve your problem, please send us your problem
and the items you checked with the results.
1) Present Trouble 2) Alarm Status
3) Presumed cause 4) Trouble shooting Check Sheet
** The format of document may be changed, but all content must be verified and recorded.
If necessary, please send us the result of reviewing the additional trouble shooting in the
Appendix.
- 9 -
3. If you send the following materials, we will be able to respond more accurately and quickly.
Especially in case that you don’t recognize what problem there is, following pictures would be
Very helpful.
3) Piping Overview Page depenging on the 4) The detailed pictures of Trouble device.
operating situation such as Main Ballasting, Example [FU_DP_HH] alarm
Main Deballasting, AP ballasting or AP
deballasting.
- 10 -
4. In special cases, the followings may be requested in addition
【END】
- 11 -
TABLE OF ALARM
3.1. TAG: [LIT-1311_LO] / [LIT-1311_LL] N.U TANK LEVEL LOW / TOO LOW ............................................................. - 28 -
3.2. TAG: [P-132(232/332)-TRIP] N.U PUMP TRIP.................................................................................................................. - 28 -
3.3. TAG: [NUPD_S(P/AP)_TO] / [NUPS_TO] / [NUPD_S(P/AP)_SP_TO] / [NUPS_SP_TO]
N.U PUMP RUN/STOP FAIL ....................................................................................................................................................... - 29 -
3.4. TAG: [DST_S/P_TO_03] /[DST_S/P_TO_03] N.U PUMP START/STOP TIME OUT ..................................... - 29 -
4.1. TAG: [TRO_LL] / [TRO_LO] TRO LOW / TOO LOW (I) .................................................................................................. - 30 -
4.2. TAG: [TRO_LL] / [TRO_LO] TRO LOW / TOO LOW (II) ................................................................................................. - 31 -
4.3. TAG: [TRO_HI] / [TRO_HH] FOR BALLASTING TRO HIGH / TOO HIGH ................................................................... - 32 -
4.4. TAG: [TRO_HI] / [TRO_HH] FOR DE-BALLASTING TRO HIGH / TOO HIGH ............................................................ - 32 -
5. ALARM LIST OF RECTIFIER .................................................................................................................. - 33 -
- 14 -
1.3. TAG: [BST_S_TO_01] / [BST_P_TO_01] / [BSP_S_TO_10] / [BSP_P_TO_10] / [BLR_BOTH_F]
BLOWER START/STOP TIME OUT / BLOWER FAIL
Description BLOWER START/STOP TIME-OUT
BOTH BLOWER FAIL ON BALLASTING
Information It will be activated when the magnetic contactor of the blower does not On/Off
after receiving blower START/STOP and blowers STOP during ballasting.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Magnetic Contactor Check the magnetic contactor is working itself or not by using T/S-BL-02
fault MANUAL operation on the HMI. If not, please replace.
2. ACONIS DI/DO Card fault See sec[6.8] HiDI16 Card & sec[6.10] HiDO16 Card T/S-ACO-GI3
T/S-ACO-GI5
- 15 -
1.5. TAG: [FIT-1131(2131)_LO] / [FIT-1131(2131)_LL] INJECTION FLOW RATE LOW / TOO LOW
Description NO.1/2 INJECTION FLOW RATE LOW
NO.1/2 INJECTION FLOW RATE TOO LOW
Information The injection flow rate is lower than the set points.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Drain valve OPEN Please check the drain valve of electrolysis unit. If it is N/A
opened, close it.
2. Incorrect position of the flow 1) Give a position command to FCV by manual T/S-FIT-01
control valve 2) Check that the FCV valve correctly works or not, where
the position of the FCV is coincided visually with
command position Calibration of positioner.
3) If not, please calibrate the valve position according to
the valve position according to T/S-FIT-01
3. Manual valve CLOSE Check that the manual valve open status from Sea water N/A
feed pump to E.U. injection point.
4. Water leakage of injection Check if there is water leakage on the pipe line. N/A
pipe
5. Malfunction of the sensor 1) Check the DC24V input power of the sensor. N/A
2) Check the analog signal connection and signal line.
For more information, please see the ref. manual.
6. Blockage of strainer of Check if the strainer is blocked or not in the seawater feed N/A
SWFU unit. If clogged, clean it.
7. Too low of main stream flow Check if the flow rate of the main ballast stream is too low, N/A
which may lead to high pressure of the main stream and
consequently it will make low injection flow.
8. Malfunction of the sensor 1) Check the DC24V input power of the sensor. N/A
2) Check the analog signal connection and signal line.
For more information, please see the ref. manual.
9. Flow unbalance of injection If the flow deviation between starboard and port side is big, N/A
lines one of two injection lines might meet the alarm.
Confirm if the pressure deviation of filters is big or not,
higher than about 1.0 bar.
10. Aconis AI card fault See sec.[6.9] HiAI16 Card T/S-ACO-GI4
- 16 -
1.6. TAG: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL] MAIN FLOW RATE LOW / TOO LOW
Description NO.1/2 MAIN FLOW RATE LOW
NO.1/2 MAIN FLOW RATE TOO LOW
Information The injection flow rate is lower than the set points.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Drain valve OPEN Please check the drain valve of electrolysis unit. If it is N/A
opened, close it.
2. Incorrect position of the flow Calibration of positioner. T/S-FIT-01
control valve T/S-FIT-02
T/S-FIT-03
T/S-FIT-04
3. Water leakage of injection Check if there is water leakage on the pipe line. N/A
pipe
4. Malfunction of the sensor 1) Check the DC24V input power of the sensor. N/A
2) Check the analog signal connection and signal line.
For more information, please see the ref. manual.
5. Blockage of filter unit 1) Do back-flushing using the ballast pump. T/S-FU-06
2) Check the filter elements are contaminated or not. If
then, please do cleaning according to the trouble shooting
manual.
6. Malfunction of the sensor 1) Check the DC24V input power of the sensor. N/A
2) Check the analog signal connection and signal line.
7. Incorrect setting of flow- Setting correctly. T/S-FIT-07
meter
8. Loosed cable connection Connect cable. T/S-FIT-08
9. Electrode damage Check resistance T/S-FIT-09
- 17 -
1.7. TAG: [BSP_S/P_TO_08] INJECTION VALVE CLOSE TIME OUT
Description INJ VALVE CLOSE TIME-OUT
Information It will be activated when it takes over 120sec to close the valve.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Incorrect position of the 1) Give a position command to FCV by manual T/S-FIT-01
flow control valve 2) Check that the FCV valve correctly works or not, where the
position of the FCV is coincided visually with command
position Calibration of positioner.
3) If not, please calibrate the valve position according to the
valve position according to T/S-FIT-01
2. Air vent of the Check if the air vent line of the positioner is blocked. N/A
positioner If blocked, please tear off some foreign materials.
3. Pressure low or fail of 1) Check if the supply pressure of the pneumatic or hydraulic N/A
the air supply for the valve is proper or not.
(Recommended Pneu. pressure: 5~7kgf/cm2)
2) Check if the air filter is filled with water/oil or not by pressing
releasing button.
4. Stuck of the Disc and 1) In case that the supply pressure and the positioner are okay, N/A
Seat please be aware of possibility of the stuck of the DISC and
SEAT.
2) Disassemble and check inside of the valve.
- 18 -
1.8. TAG: [LS-1111_LL] E.U SEPARATOR LEVEL TOO LOW
Description E.U SEPARATOR LEVEL TOO LOW
Information 1) It will be activated when the level switch(LS-1111) is OFF during ballasting
operation.
2) This level switch is very important to keep safe operation. Because the output
power of the rectifiers must be only energized while the level switch is ON.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. No feed water to 1) Check the discharge pressure of the seawater feed pump is N/A
electrolysis unit correct.
2) Check the valves on the seawater feed line to be OPEN.
Especially manual valves from the sea chest line.
3) Check the strainer on the SWFU.
4) Check the check valve at electrolysis unit inlet works correctly.
2. Injection flow Check when this alarm is occurred. If this alarm occurred right after T/S-LS-01
fluctuation due to filter filter’s back-flushing, increase injection flow control valve’s
back-flushing minimum open ratio.
4. Malfunction of the 1) Check the input power of the sensor is DC24V. N/A
sensor 2) Check the output signal cable and connector.
3) Disassemble of the sensor and check the probe visually.
4) If the level switch does not work well in a bottle, replace it.
- 19 -
1.9. TAG: [LS-1141_HI] E.U DRAIN TANK LEVEL HIGH
Description E.U DRAIN TANK LEVEL HIGH
Information 1) The alarm will be activated when the level switch(LS-1141) is ON(with Time
Delay=30sec). And then, the drain pump will be start.
2) The shutdown will be activated if the level switch(LS-1141) is still ON after the
drain pump starting.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Drain pump’s fault Check if the drain pump is working well or not. There are two type N/A
drain pumps, air driven diaphragm pump and electric driven
pump.
For air driven pump, please check the air supply line, air regulator
and filter, solenoid valve and diaphragm pump. For electric driven
pump, please check the power line, relay and the motor.
2. Contamination of level Clean fork of level switch. T/S-LS-02
switch
3. Blockage of the Check whether the tubing line of the drain pump discharge is N/A
feeding line blocked or not.
4. Blockage of the check Check if the check valve is correctly working or not at the end of N/A
valve the drain pump discharge.
5. Malfunction of the 1) Check the input power of the sensor is DC24V. N/A
sensor 2) Check the output signal cable and connector.
3) If the level switch does not work well in a bottle, replace it
- 20 -
1.10. AG: [PIT-1121_HI] BLOWER DISCHARGE PRESS HIGH
Description BLOWER DISCHARGE PRESS HIGH
Information It will be activated when the difference pressure before/after blower starting is
higher than the specific valve. It means that the H2 ventilation pipe is blocked or
other cases.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Blockage of H2 1) Firstly confirm that the blower is running and the valve is N/A
venting line OPEN.
2) Check the H2 venting pipe’s outlet is blocked or not, especially
venting head if applicable.
2. Malfunction of 1) Check the analogue output signal and connector. N/A
pressure sensor
- 21 -
1.11. TAG: [PIT-1121_LO] BLOWER DISCHARGE PRESS LOW
Description BLOWER DISCHARGE PRESS LOW
Information It will be activated when the difference pressure before/after blower starting is
lower than the specific value in the ALARM setting value.
Causes Troubleshooting/Corrective Action T/S Tag
No.
1. Malfunction of the 1) Check the input power of the sensor, DC24V. If not, please N/A
sensor check the cable, connection, and the power supply in the CC-100.
2) Check the output signal cable(4~20mA).
3) Disassemble of the sensor and check if the probe visually is
broken or not.
2. Incorrect valve Check that the valve(XV-1171 A/B) is OPEN during operation. N/A
opening
3. Incorrect blower 1) Check the blower works well. N/A
operation 2) If no working, please see Sec.[1.2] & [1.3]
4. Aconis AI card fault See Sec.[6.9] HiAI16 Card T/S-ACO-GI4
- 22 -
1.12. TAG: [TE-1111_HI] / [TE-1111_HH] FEEDING WATER TEMP HIGH
Description FEEDING WATER TEMP. HIGH
Information It will be activated when the feed water for electrolysis unit is higher than 38
deg. C for the high alarm and 55 deg. C for the shutdown, respectively.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Malfunction of the 1) Check the input power of the sensor. N/A
sensor 2) Check the output signal cable.
2. Contamination of the 1) Disassemble the measuring probe of the sensor. T/S-CIT-01
probe 2) Check the electrode of the probe and cleaning.
3) Assemble the probe and check again.
3. Abnormal valve Arrange valve correctly. Heat exchanger inlet valve(XV-1731) to T/S-TE-01
arrangement for heat be closed and heat exchanger by-pass valve(XV-1732) to be
exchanger opened.
4. Hot source water Check hot source water temperature. If it judged hotter than T/S-TE-02
temperature is too high design temperature(36 deg. C), reduce hot source water flow
rate by throttling manual butterfly valve.
5. Aconis AI card fault See Sec.[6.9] HiAI16 Card T/S-ACO-GI4
- 23 -
2. Alarm List of Filter Unit
- 25 -
2.4. TAG: [FU_DP_HH] / [FU_DP_HI] FILTER PRESS DP HIGH / TOO HIGH
Description 1) FILTER PRESS DP. TOO HIGH
2) FILTER PRESS DP. HIGH
Information It will be activated when the differential pressure between inlet and outlet
pressure is over than alarm set value, 0.7bar for alarm and 1.0bar for
shutdown, respectively.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Back-flushing valve 1) Check if the back-flushing valve is working or not by T/S-FU-05
fail pressing the “TEST” button on the filter LCP
(local control panel).
2) If not, please check the supply air and its pressure,
5~7kgf/cm2, is proper or not.
3) Check the solenoid valve and control signal.
2. Back-flushing motor 1) Check if the MCCB for motor is “OFF” in the Filter Panel. T/S-FU-06
fault If “OFF”, please turn it “ON”.
2) Check if the error lamp of KM1 contactor is on or not
inside LCP after reset. If error keeps on, please check if
there is any foreign body interrupting rotation of the back-
flushing arm inside of the filter unit
3) Check the geared motor.
3. Blockage of the air 1) Check if the air vent hole is blocked or not. If blocked, T/S-FU-07
vent please remove a foreign blocking material.
4. Blocking of the back- 1) Check if the manual valves are OPEN on the back- N/A
flushing line flushing line.
2) Check if the check valve is working or not.
5. Broken(hole) of the 1) Check if there is a broken part or a hole in the back- N/A
back-flushing line flushing line at lower part of filter unit inside.
6. Pressure sensor fail 1) Check if the inlet/outlet pressure sensors is working T/S-FU-08
properly.
2) If not, please check the cable and signal.
3) if not, please replace the sensor.
7. Clogging of the filter 1) Do backflushing using the ballast pump. T/S-FU-09
elements 2) Check the filter elements are contaminated or not. If then, T/S-FU-10
please do cleaning according to the trouble shooting
manual.
8. Aconis AI card fault See Sec.[6.9] HiAI16 Card T/S-ACO-GI4
- 26 -
2.5. TAG: [F-121(122)-F] FILTER FAULT
Description NO.1(2) FILTER (F-121/122) FAULT
Information It will be activated in case of filter fault.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Filter fault 1) Check the main switch in LCP
2) Check the terminal block with buzzer multimeter T/S-FU-11
- 27 -
3. Alarm List of Neutralization Unit
3.1. TAG: [LIT-1311_LO] / [LIT-1311_LL] N.U TANK LEVEL LOW / TOO LOW
Description 1) NU-TANK LEVEL LOW
2) NU-TANK LEVEL TOO LOW
Information It will be activated when the level of the neutralization tank goes below than
the set point.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Low level of Check the level of the neutralization tank. If low, please fill the N/A
neutralization neutralization agent.
2. Malfunction of the 1) If tank level is normal, please check the level sensor. T/S-NU-01
sensor 2) Check the input power and feedback signal.
3. Drain valve OPEN Check if the drain valve is OPEN or not. If open, please close N/A
it.
4. Leakage of the tank & Check if there is a leakage of the neutralization tank or piping. T/S-NU-02
piping
5. Damage of float Check float status. If damaged, replace it. T/S-NU-03
3. Disconnection or bad
Check and re-tight the wire connection N/A
connection of elect. cable
4. Short circuit Check insulation resistance T/S-NU-05
4. Wrong mode setting Check Auto/Manual operation mode T/S-NU-06
- 28 -
3.3. TAG: [NUPD_S(P/AP)_TO] / [NUPS_TO] / [NUPD_S(P/AP)_SP_TO] / [NUPS_SP_TO]
N.U PUMP RUN/STOP FAIL
Description [NUPD_S(P/AP)_TO] NU PUMP RUN FAIL ON DEBAL S(P/AP)
[NUPS_TO] NU PUMP RUN FAIL ON DEBAL STRIPPING
[NUPD_S(P/AP)_SP_TO]. NU PUMP STOP FAIL ON DEBAL S(P/AP)
[ NUPS_SP_TO] NU PUMP STOP FAIL ON DEBAL STRIPPING
Information It will be activated when the pump does not start or stop properly during de-
ballasting operation
Causes Troubleshooting/Corrective Action T/S Tag No.
1. No power supply Check power supply. T/S-NU-04
2. Fuse damage Check the fuse and replace it. T/S-NU-04
3. Disconnection or bad
connection of elect. Check and re-tight the wire connection N/A
cable
4. Short circuit Check insulation resistance T/S-NU-05
4. Wrong mode setting Check Auto/Manual operation mode T/S-NU-06
- 29 -
4. Alarm List of TRO Sensor Unit
- 30 -
4.2. TAG: [TRO_LL] / [TRO_LO] TRO LOW / TOO LOW (II)
Description 1) TRO LOW / TRO TOO LOW
Information 1) Too low alarm when TRO injection is lower than 5PPM for 600sec delay
time.
2) Low alarm when TRO injection is less than 5.5PPM for 600sec delay
time.
3) TRO sensor alarm code (Local)
- 31 -
4.3. TAG: [TRO_HI] / [TRO_HH] for ballasting TRO HIGH / TOO HIGH
Description 1) TRO HIGH
2) TRO TOO HIGH
Information 1) Too high alarm when TRO injection dosage is more than 10PPM for
600sec delay time.
2) High alarm when TRO injection dosage is more than 9PPM for 600sec
delay time.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Too low flow of main 1) Check the FCV-1211/2211 is working well or not. N/A
stream 2) Check the flow meter is working properly or not.
2. Too high current value of 1) Check if the output current on the rectifier during T/S-TRO-08
rectifier. operation to electrolyzer modules is within proper
range.
2) If this alarm occurs at initial startup procedure, please
reduce 10A of the initial set value of the rectifier. And
repeat.
3. Too high injection flow of 1) Check if the FCV-1131/2131 is working well or not. N/A
injection line 2) Check the flow meter is working properly or not.
4.4. TAG: [TRO_HI] / [TRO_HH] for de-ballasting TRO HIGH / TOO HIGH
Description 1) TRO HIGH
2) TRO TOO HIGH
Information 1) Too high alarm when TRO injection dosage is more than 0.1PPM for
600sec delay time.
2) High alarm when TRO injection dosage is more than 0.08PPM for 300sec
delay time.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Solenoid vale in Clean solenoid valve. T/S-TRO-09
neutralizer unit is clogged.
2. Wrong manual valve Arrange manual valve correctly. T/S-TRO-10
arrangement
3. Wrong setting of dosing Set dosing pump stroke correctly. T/S-TRO-11
pump stroke dial.
- 32 -
5. Alarm List of Rectifier
- 33 -
5.3. TAG: RF-[RF-A(B/C/D)-1002] / [REC1(2/3/4)002] RETFIER EXTERNAL E-STOP
Description RF-142A(B/C/D) EXTERNAL E-STOP
Information The external E-STOP comes from the ACONIS controller via the digital
signal or communication command.
Causes Troubleshooting/Corrective Action T/S Tag No.
1) Remove em’cy stop condition from rectifier outside.
1. External Emergency stop T/S-REC-05
2) Reset rectifier.
- 34 -
6. Alarm List of ACONIS
- 35 -
6.3. TAG : [HIMPM1M] / [HIMPM1R] / [HISCM1]
MPM / SCM CARD NO REPLY
Description HIMPM1M(R) NO REPLY / HISCM1 NO REPLY
Information It will be activated when HIMPM becomes NO REPLY.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Incorrect Please removable main(reserve) MPM from the
T/S-ACO-05
installation. baseboard and re-attach to the baseboard correctly.
2. Software problem 1) Check the LED on the front.
of MPM. 2) Please removable main(reserve) MPM from the T/S-ACO-04
baseboard and re-attach to the baseboard correctly. T/S-ACO-05
(for OS rebooting)
- 36 -
6.6. TAG : [HIMPM1_C1_ML] / [HIMPM1_C1_ML] / [HIMPM1_C1_ML] / [HIMPM1_C1_ML] / …
[HIMPM1_C1_RL] / [HIMPM1_C1_RL] / [HIMPM1_C1_RL] / [HIMPM1_C1_RL] / …
IO MODULE CARD COMMUNICATION ERROR
Description MODULE.101(102,103,104,…) (ML)/(RL) COMM ERR
Information It will be activated when the corresponding I/O CARD has LAN
communication problem.
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Disconnect LAN Check the HIMPM cable connection condition.
N/A
cable.
2. Malfunction of the 1) Check the Hub power.
hub. 2) Check the port LED of HUB.
3) Green light blinks at steady status. (Rf.1) T/S-ACO-03
4) If there is a problem with the port on the hub it should
be moved to another port.
3. Malfunction of the 1) Check power resource of the baseboard.
HIMPM baseboard 2) Check the LAN port LED of the baseboard.
3) Normal condition of LAN port’s LED is as below.(Rf.2)
T/S-ACO-06
3-1) The green light is on.
3-2) The orange light is blinking.
4) If there is problem
- 37 -
6.7. HiSCM CARD
Information Troubleshooting of HiSCM CARD itself
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Disconnect
Check the LAN cable connection condition. N/A
LAN cable
2. Malfunction of 1) Check the Hub power.
the hub 2) Check the port LED of HUB.
3) Green light blinks in normal condition. (Rf.1) T/S-ACO-03
4) If there is a problem with the port on the hub the cable
should be moved to another port.
3. CAN TX/RX error 1) Check the status of CAN communication line (main
and reserve line)
2) Check the TX operation. Green lamp blinking means
healthy status
T/S-ACO-04
3) Check the RX operation. Blue lamp blinking means
healthy status
4) Check the CAN connection line. Red lamp on means
disconnected cables.
5. Malfunction of the
1) Check power cables of the baseboard.
HISCM baseboard
2) Check the LAN port LED of the baseboard.
3) Normal condition of LAN port’s LED is as below.(Rf.2) T/S-ACO-06
3-1) The green light is on.
3-2) The orange light is blinking
- 38 -
6. To check 1) Disconnect the "LAN" cable from the LAN1 Port at
main network HiSCM.
2) Check whether "LED Indicator" at the HUB(MAIN)
is off when the "LAN" cable is disconnected.
3) Connect the "LAN" cable to the LAN1 port at
HiSCM.
4) Check whether "LED Indicator" at the HUB (MAIN)
is on when the "LAN" cable is connected.
N/A
5) Disconnect the "LAN" cable from the HUB(MAIN).
6) Check whether "LED Indicator" at HiSCM is off
when the "LAN" cable is disconnected.
7) Connect the "LAN" cable to the HUB(MAIN).
8) Check whether "LED Indicator" at HiSCM is on
when the "LAN" cable is connected.
9) ("LAN Port Numbers" are dependent on the system
cofiguration.)
7. To check 1) Disconnect the "LAN" cable from the LAN2 Port at
reserve nework HiSCM.
2) Check whether "LED Indicator" at the HUB
(RESERVE) is off when the "LAN" cable is
disconnected.
3) Connect the "LAN" cable to the LAN2 port at
HiSCM.
4) Check whether "LED Indicator" at the HUB
(RESERVE) is on when the "LAN" cable is
connected. N/A
5) Disconnect the "LAN" cable from the HUB
(RESERVE).
6) Check whether "LED Indicator" at HiSCM is off
when the "LAN" cable is disconnected.
7) Connect the "LAN" cable to the HUB (RESERVE).
8) Check whether "LED Indicator" at HiSCM is on
when the "LAN" cable is connected.
9) ("LAN Port Numbers" are dependent of system
cofiguration.)
- 39 -
6.8. HiDI16 CARD
Information Troubleshooting of HiDI16 CARD itself
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Main power 1) Check the status of power supply. If LED lamp is off,
N/A
supply error the base board connection have troubles.
2. CAN TX/RX error 1) Check the status of CAN communication line (main
and reserve line)
2) Check the TX operation. Green lamp blinking means
healthy status
T/S-ACO-04
3) Check the RX operation. Blue lamp blinking means
healthy status
4) Check the CAN connection line. Red lamp on means
disconnected line.
3. Address Number 1) Check CAN address of HiSCM. Address number
should have value between P0 - PF or S0 - SF. In
N/A
one station, every card should have a unique
address.
4. Check 16-channel 1) 3 terminals are allocated to one channel, and only 2
terminal terminals among them are used. Check the terminal
usage.
2) Check dry contact of sensor connection from LED
lamp.
3) It may be a normal state when you do short test
between applied pin no. 1 and no. 2 on the D/I
channel. and blue LED lamp is turned on. N/A
- 40 -
6.9. HiAI16 CARD
Information Troubleshooting of HiAI16 CARD itself
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Main power 1) Check the status of power supply. If LED lamp is off,
N/A
supply error the base board connection have troubles.
2. CAN TX/RX 1) Check the status of CAN communication line (main
error and reserve line)
2) Check the TX operation. Green lamp blinking means
health status
T/S-ACO-03
3) Check the RX operation. Blue lamp blinking means
health status
4) Check the CAN connection line. Red lamp on means
disconnection of line.
3. Address Number 1) Check CAN address of HiSCM. Address number
should have value between P0 - PF or S0 - SF. In
N/A
one station, every card should have a unique
address.
4. Check 16- 1) 3 terminals are allocated to one channel. Check the
channel terminal connection of field cables. Check the terminal usage.
N/A
2) LED on indicates the value is more than high limit
value(normally 21mA) or less than low limit
value(normally 3.5mA).
3) Measure the voltage between pin 1 and pin 2 with
voltage meter and verify the 24[V] voltage be shown.
4) If you connect a 2k ohrm register between pin 1 and
pin 2 and then blue led lamp turns on, Applied
channel may be a normal state.
5) When except for 3 and 4 there is abnormal.
- 41 -
6.10. HiDO16 CARD
Information Troubleshooting of HiDO16 CARD itself
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Main power 1) Check the status of power supply. If LED lamp is off,
N/A
supply error the base board connection have troubles.
2. CAN TX/RX error 1) Check the status of CAN communication line (main
and reserve line)
2) Ckeck the TX operation. Green lamp blinking means
healthy status
T/S-ACO-03
3) Ckeck the RX operation. Blue lamp blinking means
healthy status
4) Check the CAN connection line. Red lamp on means
disconnection of line.
3. Address Number 1) Check CAN address of HiSCM. Address number
should have value between P0 - PF or S0 - SF. In
N/A
one station, every card should have a unique
address.
4. Check 16-channel 1) 3 terminals are allocated to one channel. Check the
terminal connection of field cables.
N/A
- 42 -
6.11. HiAO8 CARD
Information Troubleshooting of HiAO8 CARD itself
Causes Troubleshooting/Corrective Action T/S Tag No.
1. Main power 1) Check the status of power supply. If LED lamp is off,
N/A
supply error the base board connection have troubles.
2. CAN TX/RX error 1) Check the status of CAN communication line (main
and reserve line)
2) Ckeck the TX operation. Green lamp blinking means
healthy status
T/S-ACO-03
3) Ckeck the RX operation. Blue lamp blinking means
healthy status
4) Check the CAN connection line. Red lamp on means
disconnection of line.
3. Address Number 1) Check CAN address number. Address numbers
should have numbers between 1 ~ 64 and should N/A
not be duplicated in more than one station.
4. Check 16-channel 1) 3 terminals are allocated to one channel. Check the
terminal connection of field cables.
2) Check the connection field cable. Signal type :
4~20mA
- 43 -
- 44 -
APPENDIX
- 45 -
- 46 -
TABLE OF TROUBLE SHOOTING
- 48 -
T/S-ACO-09 [ACONIS] LAN COMMUNICATION EROR ......................................................................................................................... - 186 -
T/S-ACO-10 [ACONIS] REPLACEMENT OF IO CARD ........................................................................................................................... - 187 -
T/S-ACO-11 [ACONIS] MEASURING MA SIGNAL AT HIAI CARD ...................................................................................................... - 189 -
T/S-ACO-12 [ACONIS] CHECKING DI SIGNAL ....................................................................................................................................... - 191 -
T/S-ACO-13 [ACONIS] BOOTING UP BY RECOVERY USB AT LOP ................................................................................................ - 193 -
- 49 -
T/S-H2-01 [H2 GAS DETCTOR] CALIBRATION (MODEL : DA100)
[AIT-1121(1122/1123)_HI] / [AIT-1121(1122/1123)_HH]
Alarm Tag
H2 Gas Detector Hi / Too Hi
Root Cause Incorrect reading
1. Open the detector cover by rotating it to 2. Connect all calibration devices with gas
counter clockwise as below. detector. (standard gas, regulator, nipple
and tube)
- 50 -
3-2. Press [Mode] key repeatedly until 'CA1' 3-3. When 'YES' is shown on FND, Please
is shown and then press [ENT] key to press [ENT] key to complete zero calibration.
save.
4-2. The value of FND will be increased. 4-3. Press [ENT] key over 3 seconds, Then,
'H.SC' will be shown.
- 51 -
4-4. Press [Mode] key until 'CA2' is shown 4-5. When 'ADJ' is shown, Please set the
and then press [ENT] key to save. density of standard gas by pressing
[UP] key & [DOWN] key.
4-6
a) Please press [ENT] key to save.
b) When 'YES' is shown,
then Please press [ENT] key.
c) Then, when 'HOL' is shown,
Please press [ENT] key over 3 seconds.
d) When 'END' is shown, span calibration is
completed.
【END】
- 52 -
T/S-H2-02 [H2 Gas Detector] Calibration (Model : GTD-2000EX)
[AIT-1121(1122/1123)_HI] / [AIT-1121(1122/1123)_HH]
Alarm Tag
H2 Gas Detector Hi / Too Hi
Root Cause Incorrect reading
【END】
- 53 -
T/S-BL-01 [Blower] Check EOCR setting value
[B-117A/B-F] / [B-117A/B-OFF]
Alarm Tag
E.U Blower Fault / Blower Breaker Off
Root Cause Mis-setting of EOCR
1. Find EOCR inside of motor control cabinet. 2. Check load(A) setting and if setting is
shorter than blower motor capacity,
increase it.
(ex. Motor capacity 4.5A, EOCR setting 5A)
【END】
- 54 -
T/S-BL-02 [Blower] Check the magnetic contactor status
[BST_S_TO_01] / [BST_P_TO_01] / [BSP_S_TO_10] / [BSP_P_TO_10] / [BLR_BOTH_F]
Alarm Tag
Blower Start/Stop Time Out / Blower Fail on Ballasting
Root Cause Magnetic Contactor fault
1. Find the matched equipment on MIMIC and 2. Click the START or RUN button and wait
click B-117A/B. Click the MANUAL button. for the green light on the relevant box.
3. Check magnetic contactor located inside of 4. After check, click the STOP button and
motor control cabinet. wait for the green light on the relevant
If magnetic contactor has defect, replace it. box. Then, click the AUTO button.
【END】
- 55 -
T/S-CIT-01 [Salinity Sensor] Clean sensor part
[CIT-1111_LO] / [CIT-1111_LL]
Alarm Tag
Salinity Low / Too Low
Root Cause Contamination of salinity sensor probe
3. Disconnect sensor part from the pipe. 4. Clean sensor part with a soft rag.
Caution : Before taking out transmitter, you should disconnect of transmitter at first.
Otherwise, the cable will be severely twisted or be alble to be damaged.
【END】
- 56 -
T/S-CIT-02 [Salinity Sensor] Calibration (Maker : ABB)
[CIT-1111_LO] / [CIT-1111_LL]
Alarm Tag
Salinity Low / Too Low
Root Cause Incorrect reading
Reference : . We recommend that our customers use 2.5% standard reagent for this manual. However,
in case you don’t have standard reagent, you can use the water from the condensate system with a
known salinity can be used. Or you can make salt-water by using salt and fresh-water.
3. Push the “select” button for calibration. 4. Push the “select” button for configure
calibration.
- 57 -
5. Insert the sensor into the center of 6. Push the “yes” button when the value is
container and wait until the value is stable. stable.
Please be aware that sensor shall not be
shaken. (Hands holding sensor shall not be
trembled.)
7. Set the salinity value of the seawater 8. When “SLOPE” display appear, push
(which checked at STEP1.) by using ▲ “next” button.
and ▶ button and push the “enter” button
- 58 -
9. When “OFFSET” display appear, push 10. Remove the sensor from the container and
“next” button. check the zero value.
11. Insert sensor to the center of container 12. Ensure that the value correspond to the
again and shake the sensor to remove air input value at STEP7.
during 2 seconds and wait until the value is
stable.
13. If the value is corresponded, the calibration 14. Push “Next” button if the calibrated value
is over. incorrect.
- 59 -
15. Go to “Reset Calibration” mode by using 16. When “RESET?” display appear, push
“Next” button. And push “Select” button. “yes” button.
17. Calibrated value has been reset and push 18. Please perform calibration procedure from
the “Next” button. STEP1 to STEP13.
【END】
- 60 -
T/S-FIT-01 [Positioner] Calibration (Model : YT-1000)
[FIT-1131(2131)_LO] / [FIT-1131(2131)_LL] / [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
1. a) Find the matched valve on MIMIC and 2. a) Input “0” on manual set value.
click it. :b) Push Enter button.
:b) Click the MANUAL button :c) Click “COMMAND”.
3. Press “4mA” button located at PCB of 4. a) Input “25” on manual set value.
positioner :for five(5) seconds. :b) Push Enter button.
:c) Click “COMMAND”.
- 61 -
5. Press “8mA” button located at PCB of 6. a) Input “50” on manual set value.
positioner :for five(5) seconds. :b) Push Enter button.
:c) Click “COMMAND”.
7. Press “12mA” button located at PCB of 8. a) Input “75” on manual set value.
positioner for five(5) seconds. :b) Push Enter button.
:c) Click “COMMAND”.
- 62 -
9. Press “16mA” button located at PCB of 10. a) Input “100” on manual set value.
positioner for five(5) seconds. :b) Push Enter button.
:c) Click “COMMAND”.
【END】
- 63 -
T/S-FIT-02 [Posiitoner] Calibration (Model : YT-3300 / YT-3300EX)
[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
Root Cause Incorrect position of the flow control valve
3. “AUTO CAL” will appear on display. 4. Then “AUTO 1” will appear on display.
Press the button. Press “DOWN” button.
【END】
- 64 -
T/S-FIT-03 [Posiitoner] Calibration (Model : YT-3400)
[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
Root Cause Incorrect position of the flow control valve (FCV-1131(2131))
1. Press the button for six(6) seconds. 2. “AUTO CAL” will appear on display. Then
press button.
【END】
- 65 -
T/S-FIT-04 [Posiitoner] Calibration (Model : POWER GENEX)
[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
Root Cause Incorrect position of the flow control valve (FCV-1131(2131))
【END】
- 66 -
T/S-FIT-05 [Flowmeter] Calibration (Model: DTI-200)
[FIT-3211_LO] / [FIT-3211_LL] / [FIT-3211_HI] / [FIT-3211_HH]
Alarm Tag
Flowmeter Low / High
Root Cause Incorrect reading of flow-meter
- 67 -
2. Adjust GS pump flow rate as 130% by using pump in/out pressure transmitter and pump
discharge valve. (Above performance curve is for reference. If GS pump rated capacity is
250m3/h at 85mTH, 130% means 325m3/h at 63mTH.)
- 68 -
5. Connect ampere meter to flow-meter output and adjust potentiometer slightly to meet 20mA.
6. Log in with user account on SERVER 7. Click point control window icon. And input
which is placed on ship’s office. TAG FIT-3211.
ID : aconis2000 / PW : aconis2000
- 69 -
10. Click check box as above. 11. Click OK.
【END】
- 70 -
T/S-FIT-06 [Flowmeter] Setting Correction (Maker: ABB)
[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
Root Cause Incorrect setting of flow-meter
5. Select “Advanced mode” menu by using 6. Then “Easy Setup” menu wil appear.
to confirm.
- 71 -
8. Push button until “Empty Pipe
7. Push button several times until
“Diagnostics” page appear. Detector” page appear.
9. Push button. Then Empty pipe 10. Push button. Then Empty pipe
detector on/off page will appear. Check detector on/off page will appear. Change to
setting is “off”. If setting is “on”, change to “off” by using or button.
“off”
11. Push button. Then Empty pipe 12. Push button until initial page appear.
【END】
- 72 -
T/S-FIT-07 [Flowmeter] Check Cable Connetion (Maker: ABB)
[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
Root Cause Loosed cable connection
1. Disconnect neck of flow meter. Be careful 2. Check all cable is connected well. If there
that there is cable inside of neck. is loosed connection, connect it.
【END】
- 73 -
T/S-FIT-08 [Flowmeter] Check Resitance (Maker:ABB)
[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]
Alarm Tag
Main Flow Rate Low / Too Low
Root Cause Electrode damage
5. If the measured value judged abnormal, contact Hyundai Global Service with photo of
measurement.
Hyundai Global Service: [email protected]
BWTS service team leader: [email protected]
【END】
- 74 -
T/S-LS-01 [Level Switch] If low level(LS-1111) alarm occursb at E.U separator
[LS-1111_LL]
Alarm Tag
E.U Separator Level Too Low
Root Cause Injection flow fluctuation due to filter back-flushing
If this alarm occurred right after filter’s back-flushing, increase injection flow
Trouble Shooting
control valve’s minimum open ratio.
【END】
- 75 -
T/S-LS-02 [Level Switch] If low level(LS-1141) alarm occurs at E.U drain tank
[LS-1141_HI] / [LS-1141_HH]
Alarm Tag
E.U Drain Tank Level High
Root Cause Contamination of level switch
1. Disconnect level switch from pipe line. 2. Clean fork with a soft rag.
【END】
- 76 -
T/S-TE-01 [S.W Temp Sensor] If S.W Temp high alarm (TE-1111) occurs (I)
[TE-1111_HI] / [TE-1111_HH]
Alarm Tag
Feeding Water Temp. High
Root Cause Abnormal valve arrangement for heat exchanger
3. If the valve position is not changed by 4. Turn the auto/manual switch to the auto
remote, check solenoid valve status of mode on the solenoid valve installed in
valve. pneumatic actuator.
【END】
- 77 -
T/S-TE-02 [S.W Temp Sensor] If S.W Temp high alarm (TE-1111) occurs (II)
[TE-1111_HI] / [TE-1111_HH]
Alarm Tag
Feeding Water Temp. High
Root Caus Hot source water temperature is too high
1. Check hot source temperature. Design 2. If the heat exchanger inlet hot source
temperature for heat exchanger is 36℃. temperature is higher than design
temperature, reduce flow-rate by throttling
manual inlet valve.
【END】
- 78 -
T/S-FU-01 [Filter Unit] In case that there is a problem with Bypass Valve (I)
[FUBV_OP_AL]
Alarm Tag
Filter Unit Bypass Valve Open Alarm
Root Cause Manual open
1. Check solenoid valve status of filter by- 2. Turn the auto/manual switch to the auto
pass valve. mode on the solenoid valve installed in
pneumatic actuator.
【END】
- 79 -
T/S-FU-02 [Filter Unit] In case that there is a problem with Bypass Valve (II)
[FUBV_OP_AL]
Alarm Tag
Filter Unit Bypass Valve Open Alarm
Root Cause Incorrect position of limit switch
Trouble Shooting Check the limit switch if the alarm happens without any operation.
1. Check limit switch position at local. 2. Adjust the stop bolt to rectify the incorrect
position of limit switch.
【END】
- 80 -
T/S-FU-03 [Filter Unit] In case that there is a problem with Filter Unit Valves (I)
[BST_S/P_TO_02] / [BSP_S_TO_06] / [DST_S_TO_01] / [DSP_S_TO_04]
Alarm Tag
Filter Unit Valve Open/Close Time-Out
Root Cause Pressure low or fail of the pneumatic supply for the valve
Check if the supply pressure of the pneumatic for the valve is proper.
Trouble Shooting 2
Recommended pneumatic pressure of the regulator: 5~7kgf/cm .
1. Check the air pressure for valve actuator is 2. If not, adjust regulator to supply air in range
2
in range 5~7kgf/cm . 5~7kgf/cm2.
【END】
- 81 -
T/S-FU-04 [Filter Unit] In case that there is a problem with Filter Unit Valves (II)
[BST_S/P_TO_02] / [BSP_S_TO_06] / [DST_S_TO_01] / [DSP_S_TO_04]
Alarm Tag
Filter Unit Valve Open/Close Time-Out
Root Cause Input power fail of the solenoid valve
1) Check if the input power( DC24V) is properly provided or not.
Trouble Shooting
2) If not, please check the power supply in the control cabinet.
1. Check the input power(DC24V) from the control cabinet and on the solenoid valve of filter
inlet/outlet/bypass valve with multi-meter. The diagram below is for reference only.
Please refer to your vessel’s final drawing.
- 82 -
2. Login server no.1 which is located at ship’s office or CCR.
4. Input the tag name(‘valve no.-OP (or CL’)) and click “OK”. (ex. BA046-OP)
- 83 -
5. Once PCW appear, change the mode to manual.
7. Check the LED of channel(CH) in D.O card which is installed in control cabinet. If the LED is
ON(green color), ACONIS is sending the open (or close) DO command to the valve. But if
not D.O card or ACONIS logic shall be rectified. Above card photo is just example. So
please refer to the electrical wiring diagram which had been delivered to the vessel.
- 84 -
8. If valve open(or close) command is given properly, check the valve color(green or not) on
the mimic and valve in local site.
【END】
- 85 -
T/S-FU-05 [Filter Unit] Filter Differntial press. too high (I)
[FU_DP_HH] / [FU_DP_HI]
Alarm Tag
Filter Differential Press High / Too High
Root Cause Back-flushing valve fail
1) Check if the back-flushing valve is working or not by pressing the TEST button on
the Filter local panel.
Trouble Shooting 2
2) If not, please check the supply air and its pressure, 5~7kgf/cm , is proper or not.
3) Check the solenoid valve and control signal.
1. Check if the back-flushing valve is working 2. If backflushing valve is not working well,
or not by pressing the TEST button on the please check the supply air and its
Filter local panel. pressure, 5~7kgf/cm2, is proper or not.
If pressure is low please regulate the
pressure with 5~7kgf/cm2.
- 86 -
T/S-FU-06 [Filter Unit] Filter Differntial press. too high (II)
[FU_DP_HH] / [FU_DP_HI]
Alarm Tag
Filter Differential Press High / Too High
Root Cause Back-flushing motor fault
1) Check if the MCCB for motor is “OFF” in the Filter Panel. If “OFF”, please turn it
“ON”.
2) Check if the error lamp of KM1 contactor is on or not inside LCP after reset. If
Trouble Shooting
error keeps on, please check if there is any foreign body interrupting rotation of the
back-flushing arm inside of the filter unit
3) Check the geared motor.
- 87 -
4. Check gear motor
a) Check the cable connection of motor terminal box.
b) Check the rotation direction of motor referring to the direction mark.
c) Check the output power of motor and restart motor after cooling. If motor output is lower
than the specification it may cause unstable backflushing function. It needs to be replaced
with rated capacity.
d) If above all is fine but it keeps on diffierential alarm, filter is clogging with internal particles.
It shall be required to clean the filter element.
【END】
- 88 -
T/S-FU-07 [Filter Unit] Filter Differntial press. too high (III)
[FU_DP_HH] / [FU_DP_HI]
Alarm Tag
Filter Differential Press High / Too High
Root Cause Blockage of the air vent
Check if the air vent valve is open.
Trouble Shooting
Check the valve is blocked.
【END】
- 89 -
T/S-FU-08 [Filter Unit] Filter Differntial press. too high (IV)
[FU_DP_HH] / [FU_DP_HI]
Alarm Tag
Filter Differential Press High / Too High
Root Cause Pressure sensor fail
1) Check if the inlet/outlet pressure sensors is working properly.
Trouble Shooting
2) If not, please check the cable and signal.
- 90 -
3. How to clean pressure transmitter
a) Remove sensor connector, disassemble the sensor using the spanner and clean sensor
part.
b) Close the drain valve and turn on the main switch on the LCP.
Detecting Hole
Caution : PIT Sensor is very sensetive. Therefore, please don’t use compressed air to clean.
Especially, please don’t poke detecting hole by sharpen tool.
- 91 -
T/S-FU-09 [Filter Unit] Filter Differntial press. too high (V)
[FU_DP_HH] / [FU_DP_HI]
Alarm Tag
Filter Differential Press High / Too High
Root Cause Clogging of the filter elements
1. Arrangement
:a) Arrange the valves to sea to sea mode
b) Open Sea chest valve, filter in/out valve, FCV-1211(35%) or FCV-2211(35%), Overboard
valve
2. Manual Backflushing
a) Start ballast pump without BWTS system.
b) Click “M” button and press “FLUSHING START” as like the above mimic to do backflushing
c) Back flushing will stop automatically after 30 seconds
d) Press “FLUSHING START” button every 30s for 5min to remove the particles stuck on
the filter element.
e) If the DP is still high, element of filter should be checked
【END】
- 92 -
T/S-FU-10 [Filter Unit] Filter Differntial press. too high (VI)
[FU_DP_HH] / [FU_DP_HI]
Alarm Tag
Filter Differential Press High / Too High
Root Cause Clogging of the filter elements
1) Check the filter elements are contaminated or not. If then, please do cleaning
according to the cleaning procedure.
2) It might be possible due to heavy duty over than rated flow capacity or heavy
Trouble Shooting
load including muddy and sand. In case of heavy duty, please reduce the rated flow
capacity until back-flushing becomes normal, for instance, 50% of the rated flow
capacity.
- 93 -
3. Untie earth wire on the lower part.
4. If the motor is not ATEX(not exproof-type) remove motor & sensor cable
5. If the motor is ATEX(Exproof-type), open the motor cover and untie the cable.
- 94 -
6. Use the chain block and sling belt to lift the center point of the cover plate
Caution: Lift the belt alongside the center line of the cover plate to make it easy to assemble.
- 95 -
8. a) Lift the top cover plate over the 700 mm.
b) Loosen the tefron washer using the 19mm box wrench and arrange the washer in the box
to prevent the loss
- 96 -
10. a) Clean the filter elements from outside to inside using the high pressure machine.
b) Start the cleaning of the element at a distance of the water jet about 1m
c) Slowly reduce the distance about 50cm
d) The Maximum water temperature should not exceed 60℃
e) The pressure range of the water jet should be ‘20bar<P<100bar’
(Only Fresh Water can be used)
- 97 -
12. a) Put the upper mounting plate on the filter element.
b) Tighten up tefron washer using box wrench carefully. Don’t tighten strongly, it could be
borken up.
13. a) Adjust the horizontality between the housing flange and tefron washer.
b) Match the lock-pin and lock-hole
c) Match the drive shaft and intermediate shaft.
d) Put the top cover.
14. a) Assemble the bolt & nut by the hand of ship’s crew temporarily.
b) Tighten up by air impact according to the number of the left picture(repeat 2~3 times).
c) Turn along the circle(2~3 times).
- 98 -
15. a) Reconnect the motor & earth cables
b) Close the drain valve.
c) Turn on the main switch on the LCP to power on.
【END】
- 99 -
T/S-FU-11 [Filter Unit] Filter Fault Alarm (I)
[F-121(122)-F]
Alarm Tag
Filter Fault
Root Cause Power switch off or circuit abnormal, etc,.
1. Please check whether the power switch on LCP is on or not, if switch is off, please turn on
the switch.
- 100 -
3. The no.1 lamp led of the PLC will be on when turn off the Q1 switch. If yes, the filter LCP has
no problem and it need to check other components, not filter LCP.
4. Press “ESC” button 2times and the text display will be shown. And press “ ENTER” button
then if “NO ALARMS ACTIVE” is shown on the display, it means normal condition of the filter.
【END】
- 101 -
T/S-FU-12 [Filter Unit] Filter Fault Alarm (II)
[F-121(122)-F]
Alarm Tag
Filter Fault
Root Cause CPU in stop mode alarm
1. Turn off the main switch of LCP. 2. : Pull out the cover (EEPROM connection
cover).
- 102 -
4. a) The text display shows like above photo (It will take only seconds)
b) Then turn off the main switch again
c) Remove the EEPROM, install the cover.
d) Turn on the main switch for checking and text display will show like photo below again.
☞It will take only few seconds after turning on the main switch.
5. If the message “ CPU stom in mode” shows on the display screen again after updating new
version. Change the PLC mode ” RUN→STOP→RUN”
【END】
- 103 -
T/S-FU-13 [Filter Unit] Filter Fault Alarm (III)
[F-121(122)-F]
Alarm Tag
Filter Fault
Root Cause CPU not responding
1. a) If the display shows “CPU NOT RESPONDING” message after updating program,
push the “ESC” button
b) Choice the “DIAGNOSTIC MENU” and push the “ENTER” button.
c) Choice the “BAUD RATE” and push the “ENTER” button.
d) Choice the “ TD 200 SETUP” and push the “ENTER” button.
- 104 -
2. a) Change the baud rate to 19.2K like above photo no.1
☞ Normally the default value is 19.2K.
b) Then push “ESC” button and display will show filter condition like No.4 photo.
c) But if display shows “CPU NOT RESPONDING” message again please try to change
baud rate like above photo no.2 & 3.
No.4
【END】
- 105 -
T/S-FU-14 [Filter Unit] Filter Not Ready
[F-121/221-RDY]
Alarm Tag
Filter Not Ready
Root Cause MCCB “OFF”
Trouble Shooting Check if the MCCB of filter is” OFF” or not. If “OFF”, please turn it on.
1. Check if the MCCB of filter is OFF or not. If OFF, please turn it on.
【END】
- 106 -
T/S-TRO-01 [TRO Unit] TRO Low Alarm (I)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
No water flow(Local message : WATR)
- 107 -
4. If message is “HI”, please turn regulating valve to
counter clock-wise(1/4 turn).
- 108 -
T/S-TRO-02 [TRO Unit] TRO Low Alarm (II)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
Root Cause Expired reagent life time or no reagent
DPD Powder
1. Check reagent expiration date and replacement interval.
Buffer solution to be replaced every 1 year.
Indicator & DPD powder mixture to be replaced every
90 days.
Buffer
Indicator
2. Remove the cap of small liquid indicator 3. Cap and shake it to fully dissolve the
reagent and add the contents of DPD powder.
powder bottle.
- 109 -
3. Find buffer and indicator bottle in TRO sensor.
Remove cap from each bottle and change with new one.
button.
【END】
- 110 -
T/S-TRO-03 [TRO Unit] TRO Low Alarm (III)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
Root Cause Check valve clogging
- 111 -
5. Insert end of syringe to end of each tubing. And push plunger to clean tubing and check
valve. Repeat 2~3 times. Check smooth water flow through tubing.
【END】
- 112 -
T/S-TRO-04 [TRO Unit] TRO Low Alarm (IV)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
Root Cause Dirty cuvette(Local message : GLAS)
1. Press service button. 2. Turn the knurled top on the optics system
counterclockwise until the cuvette just pops
out.
(But do not remove the top)
3. Move the retaining o-ring and push the 4. Remove the cuvette.
cuvette. The cuvette just pops out. Clean the cuvette with dry cloth and
install again.
- 113 -
6. Press SERVICE button. 7. Press PRIME button.
Then press button.
【END】
- 114 -
T/S-TRO-05 [TRO Unit] TRO Low Alarm (V)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
Root Cause No water flow(Local message : WATR)
1. Loose bolts which secure coil and valve 2. Then plunger will be come out.
body.
3. You can find plunger, spring and steel plate. Clean them.
- 115 -
T/S-TRO-06 [TRO Unit] TRO Low Alarm (VI)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
Root Cause Sample cuvette is not purged(Local Message : NPRG)
1. Press service button. This function will 2. Check sample water is drained properly
drain the water inside cuvette. through drain tube.
3. At the same time, check the purge 4. If purge solenoid valve is not turned “ON”
solenoid vlave operating lamp “ON” status. and remain “OFF” condition, check cable
connection.
5. In case abnormal is still persist, replace 6. There is possibility that drain pipe which
the purge solenoid valve. connected with TRO sensor is clogged.
Check drain pipe status from TRO sensor
to bilge well(or independent drain tank)
【END】
- 116 -
T/S-TRO-07 [TRO Unit] TRO Low Alarm (VI)
[TRO_LL] / [TRO_LO]
Alarm Tag
TRO Low / Too Low
Root Cause Analog output signal is abnormal(Local Message : MA)
3. Press button until “EXTD” display is 4. Press button until display showing
appeared. If the setting is “OFF”, change to 4MA.
“ON” by pushing “▲”or”▼” button.
5. Prepare multi-meter for signal 6. Connect multi-meter to “+” and “-“ terminal.
measurement.
- 117 -
7. If multi-meter does not indicate 4.00mA, please adjust signal by pushing “▲”or”▼” button.
- 118 -
9. If multi-meter does not indicate 20.00mA, please adjust signal by pushing “▲”or”▼” button.
【END】
- 119 -
T/S-TRO-08 [TRO Unit] TRO Low Alarm (VIII)
[TRO_HI] / [TRO_HH] for ballasting
Alarm Tag
TRO Hi / Too High
Root Cause High current of rectifier
1. In case [TRO_HI] or [TRO_HH] alarm activated within few minutes after ballasting operation,
please reduce initial current set value by 10A.(e.g. before : 500A, after : 490A)
- 120 -
2. In case [TRO_HI] or [TRO_HH] alarm activated during ballasting operation,
please increase step current reduction value. (e.g. before : 2A, after : 4A)
【END】
- 121 -
T/S-TRO-09 [TRO Unit] TRO High Alarm (I)
[TRO_HI] / [TRO_HH] for de-ballasting
Alarm Tag
TRO Hi / Too High
Root Cause Solenoid valve clogging
1. Disconnect N.U. solenoid valve from 2. Loose upper nut which secure core tube.
discharge line.
3. Remove O-ring from valve body. 4. Separate core tube from valve body by
using spanner.
5. Separate plunger from core tube. 6. Clean core tub, plunger and spring.
- 122 -
7. Reassemble in reverse order of
disassembly.
【END】
- 123 -
T/S-TRO-10 [TRO Unit] TRO High Alarm (II)
[TRO_HI] / [TRO_HH] for de-ballasting
Alarm Tag
TRO Hi / Too High
Root Cause Mis-arrangement of manual valve
【END】
- 124 -
T/S-TRO-11 [TRO Unit] TRO High Alarm (III)
[TRO_HI] / [TRO_HH] for de-ballasting
Alarm Tag
TRO Hi / Too High
Root Cause Mis-setting of N.U. pump stroke dial
1. Check N.U. pump stroke dial is set as 2. Loose dial shaft setting bolt.
100%.
【END】
- 125 -
T/S-TRO-12 [TRO Unit] Cleaning air vent of TRO purge controller
Alarm Tag TRO Communication Error
3. Pull out cap. And turn vent housing counter 4. Pull out mesh.
clockwise.
5. Pull out ball and clean it. 6. After re-assemble, shake it and check
whether the ball have movement. If there is
no stuck and normal status, ball have
movement.
【END】
- 126 -
T/S-NU-01 [NU Unit] Calibration Level Sensor
[LIT-1311_LO] / [LIT-1311_LL]
Alarm Tag
NU Tank Level Low / Too Low
Root Cause Malfunction of level transmitter
1. Disconnect level transmitter from flange. 2. Raise two floaters to the top end
(B point)
- 127 -
3-2. (Both floats position to be in B point)
Turn “SPAN1” counterclockwise slowly. If output signal indicates 20mA, stop turning of
“SPAN1”
- 128 -
3-4. (Both floats position to be in B point)
Turn “SPAN1” clockwise slowly. If output signal indicates 20mA, stop turning of “SPAN1”
4. Take down two floaters to the bottom 5. Check BWTS model. Then check minimum
end (A point). display(%) and output(mA) value on above
table.
A point B point
- 129 -
6-1. (Both floats position to be in A point)
Turn “ZERO3” counterclockwise slowly. If output signal indicates minimum display value,
stop turning of “ZERO3”
- 130 -
6-3. (Both floats position to be in A point)
Turn “ZERO3” clockwise slowly. If output signal indicates minimum display value,
stop turning of “ZERO3”
【END】
- 131 -
T/S-NU-02 [NU Unit] Reparing NU Tank
[LIT-1311_LO] / [LIT-1311_LL]
Alarm Tag
NU Tank Level Low / Too Low
Root Cause Leakage on N.U. tank
1. Prepare tool material and tool. ①PE bar 2. Grind crack part.
②Drill(small) ③Torch ④Grinder
⑤Drill(big)
3. Make V groove by using grinder. 4. Make small hole at the end of the crack
to prevent extension of crack.
- 132 -
5. Weld crack part by using torch and PE bar. 6. Make flat face by using grinder.
【END】
- 133 -
T/S-NU-03 [NU Unit] NU Tank Low Level Alarm
[LIT-1311_LO] / [LIT-1311_LL]
Alarm Tag
NU Tank Level Low / Too Low
Root Cause Damage of float
【END】
- 134 -
T/S-NU-04 [NU Unit] NU Pump Trip Alarm (I)
P-132(232/332)-TRIP
Alarm Tag
NU Pump Trip
Root Cause No power supply, fuse damage
Check power supply
Trouble Shooting
Check fuse condition and replace it, if needed.
1. Unscrew cover bolts. 2. Unscrew inner bolts.
3. Check source of electric power 4. If power source is not coming, check MCCB
(AC 380~480V). status.
【END】
- 135 -
T/S-NU-05 [NU Unit] NU Pump Trip Alarm (II)
P-132(232/332)-TRIP
Alarm Tag
NU Pump Trip
Root Cause Short circuit
5. If the measured value judged abnormal, contact Hyundai Global Service with photo of
measurement.
【END】
- 136 -
T/S-NU-06 [NU Unit] NU Pump start / stop fail
[NUPD_S(P/AP)_TO] / [ NUPS_TO] /
Alarm Tag [NUPD_S(P/AP)_SP_TO] / [ NUPS_SP_TO]
NU Pump Run/Stop Fail
Root Cause Wrong mode setting
【END】
- 137 -
T/S-NU-07 [NU Unit] Excessive Chemical Consumption
Alarm Tag Excessive neutralizer chemical consumption
1. Change the setting value of neutralizer pump according to the retention days of the treated
water in the ballast tank as referring to setting table
- 138 -
[Setting Table]
Model (Capacity) Retention days (Day) Max. Pump stroke (%) Min. Pump stroke (%)
HiB2000 ~5 60 15
(1000m3/h X 2) 5 ~ 15 50 10
15 ~ 30 5
HiB3000 ~5 60 15
(1500m3/h X 2) 5 ~ 15 40 10
15 ~ 30 5
HiB4000 ~5 60 20
(2000m3/h X 2) 5 ~ 15 50 15
15 ~ 30 5
HiB5000 ~5 60 15
(2500m3/h X 2) 5 ~ 15 40 10
15 ~ 30 5
HiB6000 ~5 50 15
(3000m3/h X 2) 5 ~ 15 40 10
15 ~ 30 5
【END】
- 139 -
T/S-REC-01 [Rectifier] Communication Error Alarm (I)
[R1(2/3)_COMM_ERR]
Alarm Tag
Rectifier Communication Error
Root Cause Cable connection fault
1. Check RS-485 cable connection is correct. This terminal is located at bottom of rectifier.
【END】
- 140 -
T/S-REC-02 [Rectifier] Communication Error Alarm (II)
[R1(2/3)_COMM_ERR]
Alarm Tag
Rectifier Communication Error
Root Cause Wrong operation mode selection
1. Check rectifier is set to “AUTO” on MIMIC. 2. Check rectifier is set to “REMOTE” on local
If not, change to “AUTO”. panel. If not, change to “REMOTE”.
【END】
- 141 -
T/S-REC-03 [Rectifier] Communication Error Alarm (III)
[R1(2/3)_COMM_ERR]
Alarm Tag
Rectifier Communication Error
Root Cause PCB malfunction
【END】
- 142 -
T/S-REC-04 [Rectifier] Communication Error Alarm (IV)
[R1(2/3)_COMM_ERR]
Alarm Tag
Rectifier Communication Error
Root Cause HiSCM card malfunction
1. Check LED status of HiSCM card. 2. HiSCM card has 8 channels for interfacing
with 3rd party system. Recitifers are
connected with each channelr. Below
photo is just for reference.
Please find channel information from final
drawing.
- 143 -
4. Push side button of HiSCM card 5. Pull HiSCM card out.
【END】
- 144 -
T/S-REC-05 [Rectifier] External E-stop
[REC1(2/3/4)002]
Alarm Tag
Rectifier Internal E-Stop
Root Cause External emergency stop
1. External emergnecy stop(Error code A16) 2. Click Reset button on rectifier MIMIC.
is come from outside of rectifier.
Remove emergency stop condition first,
then reset rectifier.
- 145 -
3. Click Reset button on MIMIC.
【END】
- 146 -
T/S-REC-06 [Rectifier] Unbalanace Current (I)
[RF-A/B/C/D-1007]
Alarm Tag.:
Rectifier Unbalance Current
Root Cause: Loosen of output cable connection, PCB malfunction
Trouble Shooting: Check output cable, compare actual value and MIMIC value
1. Check power cable connection. If loosed, 2. During ballasting operation, check actual
tighten it.(Before tightening, cut the power.) shunt value by using clamp meter.
- 147 -
4. Check shtun valve on MIMIC. 5. If there is big devaition between local and
MIMIC, PCB need to be replaced.
【END】
- 148 -
T/S-REC-07 [Rectifier] Unbalanace Current (II)
[RF-A/B/C/D-1007]
Alarm Tag.:
Rectifier Unbalance Current
Root Cause: Loosen of power feeder cable
【END】
- 149 -
T/S-REC-08 [Rectifier] Unbalanace Current (III)
[RF-A/B/C/D-1007]
Alarm Tag.:
Rectifier Unbalance Current
Root Cause: Mis-arrangement of manual valve.
【END】
- 150 -
T/S-REC-09 [Rectifier] Unbalanace Current (iV)
[RF-A(/B/C/D)-1004] / [REC-1(2/3/4)004] / [RF-A(/B/C/D)-1007] / [REC-1(2/3/4)007]
Alarm Tag.:
Rectifier Output Over Voltage
3. Close electrolyzer inlet valve(Tag No. XV-1121) and outlet valve(Tag No. MV-1111) to isolate.
MV-1111
XV-1121
- 151 -
4. For cleaning module A, please close outlet valve of module B (Tag no. : MV-1113B) and C
(Tag no. : MV-1113C).
If you want clean module B, close outlet valve of module A (Tag no. : MV-1113A) and C (Tag
no. : MV-1113C).
- 152 -
6. Prepare circulation pump and hose, connect to maintenance flange like below.
- 153 -
7. Circulate the acid solution by using 8. Repeat step 7 two times more.
cirulation pump for 2hours. And then check (Total acid cleaning time : 6 hours)
pH. If pH is above 2, add 25%(vol.) of the
acid initial filling more.
9. After cleaning, drain acid solution totally. 10. Arrange valve for normal operation.(Open
Then rinsing by fresh water circulation. electrolyzer outlet valve and inlet valve.
Close drain valve)
【END】
- 154 -
T/S-EU-01 [Electrolyzer] Electrolyzer
General Information The Arrangement of Bipolar electrode
2. Negative (-) pole’s direction should be installed to positive power source and positive (+)
pole’s direction should be installed to negative power source as below Pictures.
3. It is possible that new electrode installs to any direction because of the electrode is coated
with both side.
However, in case of reusing and reinstalling old one, you should follow our Electrode
Arrangement Guidance because negative pole side’s coating material is taken off
and electrode inside structure is changed after using.
For your information, it is normal that coating material is taken off in negative pole of
electrode and it is not effective on performance.
New Electrode
New Electrode
- 155 -
Bipolar
(+) Source
SIDE VIEW
- 156 -
T/S-ACO-GI1 [Aconis] MPM Card
General Information MPM Card
For connecting to main hub (HUB1) with main Ethernet(TCP/IP) LAN line.
LAN1
Through this port, exchange of data with server PC is possible.
For connecting to main hub (HUB2) with reserve Ethernet(TCP/IP) LAN
LAN2
line. Through this port, exchange of data with server PC is possible
HDLC Not Used
CONSOLE For debugging devices (for use bys service engineer only)
【END】
- 157 -
T/S-ACO-GI2 [Aconis] SCM Card
General Information SCM Card
2. CAN TX/RX/ERR
CAN 1 : Shows the CAN communication status of main line
When transmitting is OK : Green Lamp is blinking
When receiving is OK : Bule Lamp is blinking
When CAN communication line is disconnected : Red Lamp is solid on
CAN 2 : Same as CAN1 for reserve line
- 158 -
3. CAN Address FND
Shows CAN address of HiSCM.
4. 8-Channel LEDs
LED Indicates communication status of connected interfaces
5. Communication Port
For connecting to main hub (HUB1) with main Ethernet(TCP/IP) LAN line.
LAN1
Through this port, exchange of data with server PC is possible.
For connecting to main hub (HUB2) with reserve Ethernet(TCP/IP) LAN
LAN2
line. Through this port, exchange of data with server PC is possible
HDLC Not Used
CONSOLE For debugging devices (for use bys service engineer only)
EXL1 Extension LAN port 1
EXL2 Extension LAN port 2
【END】
- 159 -
T/S-ACO-GI3 [Aconis] HiDI Card
General Information HiDI16 Card
2. CAN TX/RX/ERR
CAN 1 : Shows the CAN communication status of main line between HiDI16 and HiMPM
When transmitting is OK : Green Lamp is blinking
When receiving is OK : Bule Lamp is blinking
When CAN communication line is disconnected : Red Lamp is solid on
CAN 2 : Same as CAN1 for reserve line
- 160 -
3. CAN Address FND
Shows CAN address of HiDI. Address has a value between 1~64. Every Card should have a
unique address.
4. 16-Channel Terminal
3 terminals are allocated to each chaennel. Only 2 terminals are used in HiDI16
5. 16-Channel LED
【END】
- 161 -
T/S-ACO-GI4 [Aconis] HiAI Card
General Information HiAI16 Card
2. CAN TX/RX/ERR
CAN 1 : Shows the CAN communication status of main line between HiAI16 and HiMPM
When transmitting is OK : Green Lamp is blinking
When receiving is OK : Bule Lamp is blinking
When CAN communication line is disconnected : Red Lamp is solid on
CAN 2 : Same as CAN1 for reserve line
- 162 -
3. CAN Address FND
Shows CAN address of HiDI. Address has a value between 1~64. Every Card should have a
unique address.
4. 16-Channel Terminal
3 terminals are allocated to each chaennel.
Siganl Type : 4~20mA
5. 16-Channel LED
LED on indicates that the received signal has a value more than the high limit (normally 21mA)
Or less than the low limit (normally 3.5mA)
【END】
- 163 -
T/S-ACO-GI5 [Aconis] HiDO Card
General Information HiDO16 Card
2. CAN TX/RX/ERR
CAN 1 : Shows the CAN communication status of main line between HiDO16 and HiMPM
When transmitting is OK : Green Lamp is blinking
When receiving is OK : Bule Lamp is blinking
When CAN communication line is disconnected : Red Lamp is solid on
CAN 2 : Same as CAN1 for reserve line
- 164 -
3. CAN Address FND
Shows CAN address of HiDI. Address has a value between 1~64. Every Card should have a
unique address.
4. 16-Channel Terminal
NO : Normally Open
C : Common
NC : Normally Closed
Max. Contact Capacity : 8A, 220VAC or 24VDC
5. 16-Channel LED
LED on indicates activated rely
【END】
- 165 -
T/S-ACO-GI6 [Aconis] HiAO Card
General Information HiAO8 Card
2. CAN TX/RX/ERR
CAN 1 : Shows the CAN communication status of main line between HiAO8 and HiMPM
When transmitting is OK : Green Lamp is blinking
When receiving is OK : Bule Lamp is blinking
When CAN communication line is disconnected : Red Lamp is solid on
CAN 2 : Same as CAN1 for reserve line
- 166 -
3. CAN Address FND
Shows CAN address of HiDI. Address has a value between 1~64. Every Card should have a
unique address.
4. 8-Channel Terminal
3 terminals are allocated to eache chennel. Only 2 terminals are used in HiAO8.
Siganl Type : Output signal with values between 4~20mA
5. 8-Channel LED
LED on indicates that the output signal has a value more than the high limit (normally 21mA)
or less than the low limit (normally 3.5mA)
【END】
- 167 -
T/S-ACO-01 [Aconis] Main source and UPS
[ACONIS1] / [ACONIS2]
Alarm Tag
Aconis No Reply
Root Cause Power fail
2-1. Check Lamp status 2-2. If necessary, the battery should be replaced
** Remark
The type of UPS may be vary depending on the vessel.
【END】
- 168 -
T/S-ACO-02 [Aconis] Recovery
[ACONIS1] / [ACONIS2]
Alarm Tag
Aconis No Reply
Root Cause There is a problem with Aconis Software
[Caution]
Before recovering your system, please contact HGS to discuss your trouble at first.
1. Plug a recovery USB device in to USB port 2. Click the “Aconis True Image Home
And turn on the computer (Full version)”
3. Click the “My Disks” of [Home→ Recover] 4. Click the “Browser: button
- 169 -
5. In case of CCR server, select the “CCR File 6.Click “Next” button
name” of Removable Drive and click the “OK”
button.
In case of MPPC server, select the “MPPC File
Name” of Removable Drive and click the “OK”
button.
7. Select the “Recover whole disks and 8. Select the “Disc2” and click the “Next”
partitions” and click the “Next” button button.
- 170 -
9. Click the “Next” button 10. Click the “Proceed” button
11. Then recovery will be proceeded 12. Click the “OK” button
13. Once click the “X” button, the computer 14. After booting of computer, check IP
will be restarted automatically. address and computer name
【END】
- 171 -
T/S-ACO-03 [Aconis] Check the IP Address
[ACONIS1] / [ACONIS2]
Alarm Tag
Aconis No Reply
Root Cause There is a problem with Aconis Software
1. Click the “Windows Start” button. 2. Click the “View network status and tasks”
Click the “Control Panel” submenu. submenu.
- 172 -
5. Select the “Internet Protocol Version 4 6.Enter “IP address”, “Subnet mask”
(TCP/IPv4)” and ”Default gateway”.
Click the “Properties” button (If you don’t know those, please contact
Hyundai Global Service)
Click the “OK” button.
- 173 -
9. Click the “Properties” button 10. Select the “Internet Protocol Version 4
(TCP/IPv4)”. Click the “Properties” button.
11. Enter “IP address”, “Subnet mask” and 12. Click the “Yes” button
“Default gateway”
(If you don’t know those, please contact
Hyundai Global Service)
Click the “OK” button.
- 174 -
T/S-ACO-04 [Aconis] Check Computer Name
[ACONIS1] / [ACONIS2]
Alarm Tag
Aconis No Reply
Root Cause There is a problem with Aconis Software
1. Click the “Windows Start” button. 2. Click the “Change settings” submenu.
Right click on “Computer” submenu.
Click the “Properties” submenu.
- 175 -
3. Click the “Change” button. 4. Enter “Computer Name”
(If you don’t know that, please contact HGS)
Click the “OK” button
- 176 -
T/S-ACO-05 [Aconis] How to Copy DB Folder & sysinfo.ini File
[ACONIS1] / [ACONIS2]
Alarm Tag
Aconis No Reply
Root Cause There is a problem with Aconis Software
1. Click the “Log In” button. 2. Enter “Supervisor ID” and “Supervisor
Password”
Click the “Ok” button.
- 177 -
5. Click the “Windows Explorer” in the Quick 6. Click the “Computer” menu.
Launch icon on No.2 Monitor. . Click the “Map network drive” submenu.
7.Input “\\10.8.1.201\d$” (No.1 Monitor which is 8. Copy DB folder from connected No.1
normal) on folder text frame. Monitor. (Z:\\ACONIS-DS\DB)
Click the “Finish” button. ▪Z:\\ACONIS-DS\DB means that connected
When “\\10.8.1.201\d$” folder is connected., Normal computer
Z:Driver shows on the Windows Explorer. ▪Copy DB folder as below.
- 178 -
9. Paste DB folder to No.2 Monitor. 10. Back the “Computer” menu.
(D:\\ACONI-DS\DB) Click the “USB DISK (l:)”.
Double click the “sysinfo” folder
11. Double click the specific folder which you 12. Copy the “sysinfo.ini” file.
triying to recover the work station.
(If you are recovering the No.1 Server, please
double click No.1 Server foler.)
- 179 -
13. Back the “Computer” menu and click the 14. Once the window appear, click the “Copy
“Local Disk (D:).” and Replace.”
Double click the “Aconis-DS” and then double
click the “INI” folder.
Paste “sysinfor.ini” file.
- 180 -
T/S-ACO-06 [Aconis] Communication Error
[ACONI_ML] / [ACONIS1_RL] / [ACONIS2_ML] / [ACONIS2_RL]
Alarm Tag
Aconis Communication Error
Root Cause LAN Hub Problem
2. Green light blinks at steady status 3. If there is a problem with the port on the hub
it should be move to another port
【END】
- 181 -
T/S-ACO-07 [Aconis] Connection Trouble
[HIMPM1M] / [HIMPM1R] / [HISCM1]
SCM & MPM Card No Reply
Alarm Tag
[HIMPM C1 ML1] / [HIMPM C1 RL1] / [HIMPM1 C3 ML1] / [HIMPM1 C4 ML]
[HIMPM1_C1] / [HIMPM1_C2] / [HIMPM1_C3] / [HIMPM1_C4] / [HIMPM1_C5] / …
IO Card Line Error
Root Cause There is a problem with connection
Green / Blue
(Flickering)
Normal Normal Communication OK
Red (Steady)
Comm. Comm.
Error Error
- 182 -
2. In case that you find communication error, check conncetion Status with base board
and push card to baseboard for tightening electrical connection and connect baseboard tightly
【END】
- 183 -
T/S-ACO-08 [Aconis] To reset Module Card
[HIMPM1M] / [HIMPM1R] / [HISCM1]
SCM & MPM Card No Reply
Alarm Tag
[HIMPM1_C1] / [HIMPM1_C2] / [HIMPM1_C3] / [HIMPM1_C4] / [HIMPM1_C5] / …
I/O Card(Module) No Reply
Root Cause Software Trouble of SCM, MPM & I/O Card
1. Push the side button of the card 2. Pull out the card out
3. Remove the card from baseboard to reset 4. Mount the card on the baseboard securely
- 184 -
5-1. Check card’s LED status. 5-2. Check card’s LED status.
▪ DOT in FND display wil lbe flickering in normal ▪ Both in CAN1 and CAN2 LED has to be flickering
condition. With Green/Blue color in normal condition,
▪ If this DOT is either off or steady, it means that
CPU is hanging up.
6. After you try to reset cards, if some alarms occur continuously or LED shows some cards are
in trouble, you should replace the relevant card with spare one.
【END】
- 185 -
T/S-ACO-09 [Aconis] LAN communication Eror
[HIMPM1_ML] / [HIMPM1_RL] / [HIMPR1_ML] / [HIMPR1_RL] / [HISCM1_ML] /
[HISCM1_RL]
LAN Communication Error of MPM Card
Alarm Tag
[HIMPM1_C1_ML] / [HIMPM1_C1_ML] / [HIMPM1_C1_ML] / [HIMPM1_C1_ML]
[HIMPM1_C1_RL] / [HIMPM1_C1_RL] / [HIMPM1_C1_RL] / [HIMPM1_C1_RL]
LAN Communication Error of I/O Card
Root Cause Baseboard Problem
1. Check power resource of the baseboard 2. Check the LAN port LED of the baseboard
3. Normal condition
3-1) The Green Light is on
3-2) The Orange Light is blinking
【END】
- 186 -
T/S-ACO-10 [Aconis] Replacement of IO card
Alarm Tag IO CARD Replacement
3. Using a small minus screw drrive, set 4. For example, adjust address 01.
address of new IO card as same as you SW2 is 0 and SW1 is 1
need to relpace one
- 187 -
5. Mount new IO to baseboard and check
status.
【END】
- 188 -
T/S-ACO-11 [Aconis] Measuring mA signal at HiAI Card
Alarm Tag Sensor Fault
1. HiAI16 is connected to sensors by wire. Each channel in HiAI16 consist of three(3) terminals.
1-1) In case DC 24V Power supplied by 1-2) In case DC 24V power supplied by HiAI16
sensor, cables should be connected with module, cables should be connected with
lower 2 terminals. upper 2 terminals.
[DC 24V power from Sensor] [DC 24V power from HiAI16 Module]
- 189 -
3. From terminal of HiAI16 module, disconnect one 4. Measure circuit current by multimeter.
cable which you need to measure.
【END】
- 190 -
T/S-ACO-12 [Aconis] Checking DI signal
Alarm Tag Communication Error
1.When pump or sensor is on, related Chanels on HiDI card and signal on Aconis should be on.
For example, when you start No.1 ballast pump, if the signal is not changed on Aconis, you
have to check HiDI card at first as follows.
2. From terminal of related DI card, disconnect signal cables like a picture below.
- 191 -
3. Make short circuit by inserting of cable into CH04 terminal, then Green LED will be On at
CH04
If you make short circuit correctly and card is normal, Green LED will be On at CH04 and
related signal will be changed on Aconis screen.
【END】
- 192 -
T/S-ACO-13 [Aconis] Booting up by Recovery USB at LOP
[ACONIS1] / [ACONIS2]
Alarm Tag
Aconis No Reply
Root Cause There is a problem with Aconis Software
LOP
- 193 -
3. Connect the keyboard to LOP server
- 194 -
6. Then LOP server screen will be changed as below.
7 Select “USB SMI USB DISK” by using an arrow button (↑or↓) and press enter key.
- 195 -
Head office
Centum Science Park, 79, Centum Jungang-ro,
Haeundae-gu, Busan 48058, Rep. of Korea
Tel +82 52 204 7600~1, Fax +82 52 204 7700