0% found this document useful (0 votes)
23 views104 pages

Install SCT On WinXP-WinVista-Win7 - Mauro Quadraruopolo

WinXP

Uploaded by

afmazoni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views104 pages

Install SCT On WinXP-WinVista-Win7 - Mauro Quadraruopolo

WinXP

Uploaded by

afmazoni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 104

mauro.quadraruopolo@siaemic.

com

Installing
SubnetworkCraftTerminal
on
Windows XP/Vista/7

1
Copyright Siae Microelettronica S.p.a.
How to make for XP? 1/29
 Install SCT

2
Copyright Siae Microelettronica S.p.a.
How to make for XP? 2/29

3
Copyright Siae Microelettronica S.p.a.
How to make for XP? 3/29

4
Copyright Siae Microelettronica S.p.a.
How to make for XP? 4/29

5
Copyright Siae Microelettronica S.p.a.
How to make for XP? 5/29

6
Copyright Siae Microelettronica S.p.a.
How to make for XP? 6/29

7
Copyright Siae Microelettronica S.p.a.
How to make for XP? 7/29

8
Copyright Siae Microelettronica S.p.a.
How to make for XP? 8/29

9
Copyright Siae Microelettronica S.p.a.
How to make for XP? 9/29

During the installation


is not very important to
choose serial or LAN
because the setting can
be changed any time in
SCT -> options ->
connection

10
Copyright Siae Microelettronica S.p.a.
How to make for XP? 10/29

11
Copyright Siae Microelettronica S.p.a.
How to make for XP? 11/29
 Installing connection via RS232

12
Copyright Siae Microelettronica S.p.a.
How to make for XP? 12/29

13
Copyright Siae Microelettronica S.p.a.
How to make for XP? 13/29



14
Copyright Siae Microelettronica S.p.a.
How to make for XP? 14/29

15
Copyright Siae Microelettronica S.p.a.
How to make for XP? 15/29

“C:\Program Files\sct\DRV”

16
Copyright Siae Microelettronica S.p.a.
How to make for XP? 16/29
 Select PPP- Direct connection to equipment


17
Copyright Siae Microelettronica S.p.a.
How to make for XP? 17/29
 Select port where you will connect serial cable
RS232

 If you use an adaptator usb/rs232 connect its and


select the virtual port present in the list (COM#) 18
Copyright Siae Microelettronica S.p.a.
How to make for XP? 18/29

19
Copyright Siae Microelettronica S.p.a.
How to make for XP? 19/29

20
Copyright Siae Microelettronica S.p.a.
How to make for XP? 20/29

21
Copyright Siae Microelettronica S.p.a.
How to make for XP? 21/29
1 – SCT 2
- Connection

4
3

22
Copyright Siae Microelettronica S.p.a.
How to make for XP? 22/29
 Insert cable USB in the port LCT of the
equipment

23
Copyright Siae Microelettronica S.p.a.
How to make for XP? 23/29

24
Copyright Siae Microelettronica S.p.a.
How to make for XP? 24/29


25
Copyright Siae Microelettronica S.p.a.
How to make for XP? 25/29

26
Copyright Siae Microelettronica S.p.a.
How to make for XP? 26/29

27
Copyright Siae Microelettronica S.p.a.
How to make for XP? 27/29

28
Copyright Siae Microelettronica S.p.a.
How to make for XP? 28/29

29
Copyright Siae Microelettronica S.p.a.
How to make for XP? 29/29

30
Copyright Siae Microelettronica S.p.a.
Installing
SubnetworkCraftTerminal
on
Windows Vista
(tried on version 32 bit)

31
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 1/15

 The substantial difference


between Windows XP
and Windows Vista is
that this last one does not
create automatically dial
up connection
LctDirectPPP that allows
the logon with the
equipment… and
therefore must be insert
manually.
32
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 2/15

 Start -> Connect To

1° Copyright Siae Microelettronica S.p.a. 33


How to make for Vista? 3/15

 Set up a connection or Network

34
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 4/15



35
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 5/15
 Dial-up phone number: 123
 Connection name: LctDirectPPP

36
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 6/15

37
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 7/15

38
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 8/15

39
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 9/15
 Press Start -> Control Panel (classic)-> Network
and Sharing Center -> Manage network connection

40
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 10/15

 Double click
LctDirectPPP

41
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 11/15

 Press
Properties
42
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 12/15
 General -> Configure

43
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 13/15
 Options -> Security

44
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 14/15
 Networking ->
1° Internet protocol
version 4
2° (TCP/IPv4) ->
Properties

45
Copyright Siae Microelettronica S.p.a.
How to make for Vista? 15/15
 Press Advanced … -> deselect PPP link


46
Now, you can connect using direct serial cable
Copyright Siae Microelettronica S.p.a.
Installing
SubnetworkCraftTerminal
on
Windows 7
( 32bit and 64bit )

47
Copyright Siae Microelettronica S.p.a.
Installing SCT on Win7 1/41

2
48
Installing SCT on Win7 2/41

3
49
Installing SCT on Win7 3/41

2 Insert the product key


1

50
Installing SCT on Win7 4/41

2
1

51
Installing SCT on Win7 5/41

52
Installing SCT on Win7 6/41

53
Installing SCT on Win7 7/41

2 Right button of mouse in Start -


Computer

1 54
Installing SCT on Win7 8/41

3 Device Manager
1
This information are
necessary for decide which
driver I will have to select

55
Installing SCT on Win7 9/41

Cable USB disconnect Cable USB connect


from IDU from IDU 56
Installing SCT on Win7 10/41
1 right button of the mouse

57
Installing SCT on Win7 11/41
Browse directory : C:\Program Files\sct\DRV\USB\

3
For Operation System Microsoft Windows:
-x86 (32bit): WinXp,Win 2000,WinVista,Win7; select folder Win32_XP_Win2K_vista_7
-64bit: WinVista, Win7; select Win64_Vista_7 ; select folder Win64_Vista_7

58
Installing SCT on Win7 12/41
For Operation System Microsoft Windows:
-x86 (32bit): WinXp,Win 2000,WinVista,Win7; select
folder C:\Program
Files\sct\DRV\Win32_XP_Win2K_vista_7

For Operation System Microsoft Windows:


64bit: WinVista, Win7; select Win64_Vista_7
; select folder C:\Program
Files\sct\DRV\USB\Win64_Vista_7

59
Installing SCT on Win7 13/41

1
60
Installing SCT on Win7 14/41

2
1

61
Installing SCT on Win7 15/41

1 2

62
Installing SCT on Win7 16/41

1 2

Erio Connection USB 4


ModemDirect work only with
the COM port number belong
from COM1 up to COM6
(choose one free) 63
Installing SCT on Win7 17/41

1 2

64
Installing SCT on Win7 18/41

65
Installing SCT on Win7 19/41

66
Installing SCT on Win7 20/41

67
Installing SCT on Win7 21/41

2
68
Installing SCT on Win7 22/41

3
1
2

All without flag

69
Installing SCT on Win7 23/41
1 5

4 enable extension LCP and software compression


70
Installing SCT on Win7 24/41

2
3

71
Installing SCT on Win7 25/41
1

1 Without compression

72
Installing SCT on Win7 26/41
1 3

73
Installing SCT on Win7 27/41

74
Installing SCT on Win7 28/41

75
Installing SCT on Win7 29/41

76
Installing SCT on Win7 30/41

77
Installing SCT on Win7 31/41

78
Installing SCT on Win7 32/41

79
Installing SCT on Win7 33/41

80
Installing SCT on Win7 34/41

81
Installing SCT on Win7 35/41

82
Installing SCT on Win7 36/41
1 2 3

4 83
Installing SCT on Win7 37/41

2
1

All without flag

3
4

84
Installing SCT on Win7 38/41

85
Installing SCT on Win7 39/41

86
Installing SCT on Win7 40/41

1
2
SYSTEM

SIAEMICR

SIAEMICR

3 x

4 5

87
Installing SCT on Win7 41/41

88
Issues during the installation
of SubnetworkCraftTerminal
on WinVista / Win7

89
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 1/14

 The substantial difference


between Windows XP
and Windows 7 is that
this last one couldn’t
create automatically the
dial up connection
LctDirectPPP that allows
the logon with the
equipment… and
therefore must be insert
manually.
90
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 2/14
1°Switch on the
equipment radio
and connect to PC
with usb cable.

2° Automatically Win7
adds "Erio
Connection" in the
list of modem.

91
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 3/14
Now create the
connection
dial-up Start ->
Control Panel

1° Copyright Siae Microelettronica S.p.a.


92
How to make for Win7? 4/14


Set up a connection
or a network

93
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 5/14

Set up dial-up connection



Next
94
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 6/14
 Dial-up phone number: 123
 Connection name: LctDirectPPP

Connect
95
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 7/14

Set up the connection anyway

close

96
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 8/14

Change adapter Settings

Properties

97
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 9/14

Without Hardware Check

close

98
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 10/14

close
Setting PPP

99
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 11/14

100
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 12/14

Without PPP Link

close

101
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 13/14
Execute SCT -> Options -> connection

102
Copyright Siae Microelettronica S.p.a.
How to make for Win7? 14/14

Disable Hardware
Flow control

Close SCT and


restart again

103
Copyright Siae Microelettronica S.p.a.
And …if you have problems?

contact:
[email protected]

104
Copyright Siae Microelettronica S.p.a.

You might also like