UNI RATE
ITEM DESCRIPTION QTY
T USD
1 PLUMBING FIXTURE
Install ,connect ,plumbing fixtures trim and accessories complete
including mixers, faucets, water supplies connections , drainage
connections, stop angle valves, flexible connections , ablution
faucets , chrome bottle traps. All as per specified by architect and
as shown on drawings.
1.1 Lavatory No. 124 334.8
1.2 Water closet S trap No. 63 529.2
1.3 GPR TANK No. 2 1250
1.4 Booster Pump No. 4 3125
1.5 Circulation Pump No. 1 1050
Total
2 PIPING SYSTEM
2.1 DOMESTIC COLD WATER PIPING SYSTEM
Supply, install, connect, and test of(PPR) piping(inner diameter/PN
16) systems for Domestic cold water systems complete with water
hammer arrestors, including molded injected fittings , supports ,
hangers , air vent valve and fittings and all other accessories and
as shown on drawings.
2.1.1 32 mm diam . Piping M. 220 7.02
2.1.2 40 mm diam . Piping M. 411 10.53
2.1.3 50 mm diam . Piping M. 515 13.23
2.1.4 63 mm diam . Piping M. 4 17.01
2.1.5 75 mm diam . Piping M. 164 22.68
Total
2.2 DOMESTIC HOT WATER PIPING
Supply, install, connect, and test of (PPR composit layer type
/CPVC/copper/St.St(304)/HDPE) piping(inner diameter/PN20)
systems for Domestic hot water systems complete with water
hammer arrestors, including fittings , supports , hangars,
insulation , aluminium covers for outdoor installation, ,expansion
connections and fittings and all other accessories and as shown
on drawings.
2.2.1 25 mm diam . Piping M. 38 6
2.2.2 32 mm diam . Piping M. 33 7
2.2.3 40 mm diam . Piping M. 107 11
Total
3 DRAINAGE PIPING SYSTEM
Supply, install, connect and test all soil, waste and vent
(UPVC/PPR/HDPE/hub less cast iron / St.St(304)) (PN.10/inner
diameter) vertical & horizontal aboveground piping system
complete including clean outs fittings, roof vent caps, couplings,
supports, insulation and sound proof insulations for critical zones,
hangers and all other accessories as specified and as shown on
drawings.
3.1 20mm diam.Piping M. 1,000 3
3.2 25mm diam.Piping M. 114 3
3.3 40mm diam.Piping M. 65 6
3.4 75mm diam.Piping M. 530 11
3.5 100 mm diam.Piping M. 516 16.74
1
3.6 125 mm diam.Piping M. 15 31.59
Total
4 FLOOR DRAINS
4.1 75mm diam. No. 79 67.50
5 TRENCH DRAIN
Supply, install, connect and test of heavy duty (C.I) grating with
5.1 concrete trench drain body including traps ,insulation,
sedimentation buckets and floor drain all as specified and as shown
on drawings.
Length 1000 mm X Width 150mm No. 16 148.5
2
6 GULLY TRAP
Supply, install, connect and test of gully trap including ductile iron
cover and all necessary accessories and connections , traps , No. 2 94.5
sedimentation buckets and all ancillaries all as specified and as
shown on drawings.
7 GREASE INTERSEPTOR :
Supply and Installation of Grease Interceptor with a Flow Rate
Capacity of 10 Gallons Per Minute (GPM)
Includes :-
The interceptor is made of stainless steel to ensure corrosion
resistance and long service life, or from another approved material
based on project requirements.
The unit includes chambers for separating grease and oils from
wastewater before discharging into the drainage system.
7.1
The interceptor is supplied with all required connections, including
pipes, valves, and fittings, to ensure integration with the drainage
system.
Installation includes placing the unit at the designated location
according to the construction drawings, ensuring complete and
proper connection to the drainage system.and all as required to
complete the work according to the drawings and specifications.
8 CONTROL VALVES
Supply, install, connect, test of control valves including all fittings ,
connections and pressure gauges and all accessories as specified
and as shown on drawings .
8.1 25 mm diam. No. 3 60.75
8.2 32 mm diam. No. 2 75.6
8.3 - 50 mm diam. No. 1 108
Total
9 ELECTRICAL WATER HEATER
Supplying, installing, of a single electric water heater with a
capacity (to be specified, e.g., 10 or 30 liters) as per project
requirements.
The heater is made of high-quality materials to ensure heating
efficiency and long service life.The heater includes an over-
temperature protection system and a safety valve to ensure safe
usage. The heater is provided with all required connections,
including pipes, valves, and fittings, to ensure integration with the
plumbing and water system.
Installation includes placing the heater at the designated location as
per construction drawings, connecting the necessary electrical
supply, and testing the heater to ensure proper operation.
9.1 EWH 300 LIT-25KW No. 2 2500
10 Valves
3
10.1 Gate Valves (110 mm diam) No. 4 148.5
10.2 Gate Valves (75 mm diam) No. 7 126.9
10.3 Gate Valves (50 mm diam) No. 10 108
10.4 Gate Valves (40 mm diam) No. 7 94.5
10.5 Gate Valves (32 mm diam) No. 50 75.6
10.6 Gate Valves (25 mm diam) No. 7 60.75
Total
11 flow meter
11.1 flow meter (75 mm diam) No. 1 337.5
11.2 flow meter (50 mm diam) No. 15 229.5
11.3 flow meter (32 mm diam) No. 65 175.5
Total
Total
4
AMOUNT
USD
41,515
33,340
2,500
12,500
1,050
90,905
1,544
4,328
6,813
68
3,720
16,473
215
232
1,127
1,574
2,970
369
369
6,010
8,638
5
474
18,830
5,333
2,376
6
189
182
151
108
441
5,000
7
594
888
1,080
662
3,780
425
7,429
338
3,443
11,408
15,188
163,737