Data Sheet For DX Concealed Units
Data Sheet For DX Concealed Units
YEKE(18-60)BZL(R)3CJOW3M
Indoor Unit
• DC fan motor
• High Air flow
• Adjusted pressure by wired controller
• Wireless controller(optional)
• Blue fin
Condensing Unit
Standard
• Larger fan, slower speed to reduce noise
• DC inverter compressor and motor
• Built-in valve, 4-way pipe connection
• “888” digital test panel
• Blue fin
The YORK® line of MSP duct Air conditioners includes a wide range of sizes to
give you more flexibility in your product offering. Each model is designed to
provide comfort and efficiency, in an easy-to-operate unit and the sleek design
fits a variety of spaces, whether it’s in a home or office. Models meet the highest
energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Both the condensing and indoor units are engineered for quiet
operation. And comfort control settings are easily changed with the touch of a
button on the remote control.
2
24 Hour Timer 3 Minutes Protection
Allows programmed start times up to A 3-minute delay before the
24 hours in advance for flexible and compressor will restart helps
more convenient operation. avoid compressor damage and
24
extend compressor life.
Electrical Defrosting
Child Lock Automatic deicing of outdoor unit
If the lock button on the remote below certain temperatures helps
Features and benefits control is pressed, it must be
pressed again before use, which
ensure proper operation, saves
energy and improves efficiency.
helps prevent accidental operation. (Heat pump only)
3-Minute Protection
3 Minutes Protection
Auto Restart Low Ambient Cooling at -15°C
Auto restart The AC will run in cooling mode
p to
nd A 3-minute delay before the compressor will
A 3-minute delay before the
compressor will restart helps AUTO
Unit is automatically returned to previous
Unit is automatically returned to when outdoor temperature is
previous operating conditions after below -15°C to meet special
restart helps avoid compressor damage and
avoid compressor damage and
extend compressor life.
operating conditions after a power outage,
a power outage, for simplified for applications.
user-requested
operation. -15 C o
(Cooling only. Standard for
work time. simplified operation. Unitary Smart DC inverter types.
Optional for others.)
Electrical Defrosting
Automatic deicing of outdoor unit
24-Hour Timer
below certain temperatures helps
24 Hourproper
ensure Timeroperation, saves 3 Minutes Protection
Self Diagnosis
Allows programmed
and improves start times up to
n. Allows programmed start times up to 24
energy
24 hours
(Heat pumpin advance
only)
efficiency.
for flexible and hours
A 3-minute delay before the
compressor will restart helps
Clearly displayed failure codes allow for quicker
more convenient operation.
24 in advance for flexible and more convenient
avoid compressor damage and
extend compressor life.
troubleshooting and easier maintenance.
operation.
Low Ambient Heating at -20°C
The AC will run in heating mode
ff when outdoor temperature is below
20°C Electrical Defrosting
Childto meet special user-requested
Lock Automatic deicing of outdoor unit
-20oC applications. (Heaton
If the lock button pump only)
the remote below certain temperatures helps
control is pressed, it must be ensure proper operation, saves
pressed again before use, which energy and improves efficiency.
helps prevent accidental operation. (Heat pump only)
3
Specification
York Set Model YEKE18BZL3CJOW3M YEKE24BZL3CJOW3M YEKE36BZL3CJOW3M
York Outdoor Model YEKE18BYL3CJO-3M YEKE24BYL3CJO-3M YEKE36BYL3CJO-3M
York Indoor Model YEKE18BXL3CJ-W3M YEKE24BXL3CJ-W3M YEKE36BXL3CJ-W3M
Power supply Ph/V/Hz 1/220~240/60 1/220~240/60 1/220~240/60
Power supply at rated capacity Ph/V/Hz 1/230/60 1/230/60 1/230/60
Capacity Btu/h 18,000(6,000~22,320) 21,800(8,300~27,000) 33,000(10,000~40,000)
Capacity kW 5.28(1.76~6.45) 6.39(2.43~7.91) 9.70(2.93~11.7)
Input kW 1.45 1.76 2.66
Rated Cooling(T1)
Running current A 8.08 10.03 11.90
EER W/W 3.64 3.63 3.64
EER Btu/hW 12.40 12.40 12.40
Capacity Btu/h 16,400(5,000~18,000) 19,600(6,500~23,000) 31,000(8,000~33,000)
Capacity kW 4.80(1.46~5.27) 5.73(1.90~6.74) 9.10(2.34~9.6)
Input kW 1.89 2.25 3.56
Rated Cooling(T3)
Running current A 10.35 12.33 14.39
EER W/W 2.54 2.55 2.55
EER Btu/hW 8.70 8.70 8.70
Capacity Btu/h 18,260(6,000~22,500) 24,600(7,985~27,507) 35,636(10,000~40,270)
Capacity kW 5.35(1.76~6.59) 7.20(2.34~8.06) 10.45(2.93~11.8)
Input kW 1.50 2.02 2.94
Rated Heating(T1)
Running current A 8.14 10.02 13.01
COP W/W 3.55 3.55 3.55
COP Btu/hW 12.12 12.12 12.12
Moisture Removal l/h 0.95 1.2 1.7
Max. input consumption W 2300 2700 5100
Max. current A 12 15 22.4
Operation Control Wired Wired Wired
Input W 160 200 200
Output W / / /
Indoor fan motor Running current A 0.75 0.87 0.87
Capacitor uF / / /
Speed rpm 850/750/650/600 860/760/660/600 900/840/780/750
Indoor air flow m3/h 1480/1280/1150/950 1500/1300/1180/950 2000/1740/1500/1280
External static pressure Pa 25 (0~100) 25 (0~100) 37(0~150)
Indoor noise level (Sound pressure level) dB(A) 42/40/39/36 45/42/40/36 48/45/42/39
Unit (WxDxH) mm 1100×700×248 1100×700×248 1500×700×248
Indoor dimension
Packing (WxDxH) mm 1340×870×330 1340×870×320 1710×870×330
Indoor weight Net/Gross kg 31/35 31/35 46/55
Type rotary rotary rotary
Capacity W/h 4410 4410 7000
Input W 1335 1335 2150
Compressor
Rated current(RLA) A 8.5 8.5 8.7
Thermal protector external external external
Refrigerant oil ml 350 350 520
Input W 128 128 190
Outdoor fan motor
Speed rpm 850 850 800±40
Outdoor air flow m3/h 3300 3300 5500
Outdoor noise level (Sound pressure level) dB(A) 60 60 65
Outdoor dimension Unit/Packing (WxDxH) mm 890×340×700/1046×460×780 920×372×760/1085×487×843 950×370×1350/1090×480×1500
Outdoor weight Net/Gross kg 46.5/51.5 54/60 103/110
Type R410A R410A R410A
Refrigerant
Charge g 1850 2000 3700
Liquid side/Gas side mm 9.52/15.88 9.52/15.88 9.52/19.05
Refrigerant pipe Max. refrigerant pipe length m 25 30 50
Max. difference in level m 15 15 30
Operation temperature range ℃ 16-30 16-30 16-30
Ambient temperature range ℃ 10~52 10~52 10~52
Qty’per 20’& 40’&40HQ Set 36/75/85 31/66/76 24/52/59
4
Specification
York Set Model YEKE48BZL3CJOW3M YEKE48BZR3CJOW3M YEKE60BZR3CJOW3M
York Outdoor Model YEKE48BYL3CJO-3M YEKE48BYR3CJO-3M YEKE60BYR3CJO-3M
York Indoor Model YEKE48BXL3CJ-W3M YEKE48BXL3CJ-W3M YEKE60BXL3CJ-W3M
Power supply Ph/V/Hz 1/220~240/60 3/380~415/60 3/380~415/60
Power supply at rated capacity Ph/V/Hz 1/230/60 3/400/60 3/400/60
Capacity Btu/h 46,000(18,000~62,000) 46,000(18,000~62,000) 54,000(18,000~72,000)
Capacity kW 13.5(5.27~18.2) 13.5(5.27~18.2) 15.8(5.27~21.09)
Input kW 3.71 3.71 4.35
Rated Cooling(T1)
Running current A 17.30 6.20 7.20
EER W/W 3.63 3.63 3.63
EER Btu/hW 12.40 12.40 12.40
Capacity Btu/h 43,600(15,000~52,000) 43,600(15,000~52,000) 48,600(15,000~55,000)
Capacity kW 12.75(4.40~15.2) 12.75(4.40~15.2) 14.25(4.40~16.12)
Input kW 5.00 5.00 5.586
Rated Cooling(T3)
Running current A 23.80 8.10 8.8
EER W/W 2.55 2.55 2.55
EER Btu/hW 8.70 8.70 8.7
Capacity Btu/h 53,920(20,477~71,669) 53,920(20,477~71,669) 60,000(20,477~72,000)
Capacity kW 15.80(6.0~21.0) 15.80(6.0~21.0) 17.60(6.0~21.0)
Input kW 4.39 4.39 4.89
Rated Heating(T1)
Running current A 20.50 5.09 8.00
COP W/W 3.60 3.60 3.60
COP Btu/hW 12.30 12.30 12.30
Moisture Removal l/h 1.1 1 1
Max. input consumption W 9600 9600 10600
Max. current A 36 12 14
Operation Control Wired Wired Wired
Input W 300 300 1210
Output W 197 197 980
Indoor fan motor Running current A 1.3 1.3 5.5
Capacitor uF / / /
Speed rpm 1100/910/800/750 1100/910/800/750 950/880/850/810
Indoor air flow m3/h 3980/3300/2750/2280 3980/3300/2750/2280 3980/3300/2750/2280
External static pressure Pa 50(0~160) 50(0~160) 50(0~160)
Indoor noise level (Sound pressure level) dB(A) 50/47/45/42 50/47/45/42 51/48/46/43
Unit (WxDxH) mm 1350×490×425 1350×490×425 1336×750×500
Indoor dimension
Packing (WxDxH) mm 1565/724/510 1565/724/510 1609×946×649
Indoor weight Net/Gross kg 61/72 61/72 99/130
Type rotary rotary rotary
Capacity W/h 13780 13780 13780
Input W 4130 4060 4060
Compressor
Rated current(RLA) A 15.8 12.3 12.3
Thermal protector external external external
Refrigerant oil ml 1600 1600 1400
Input W 190 190 190
Outdoor fan motor
Speed rpm 900±40 900±40 900±40
Outdoor air flow m3/h 7500 7500 7500
Outdoor noise level (Sound pressure level) dB(A) 65 65 65
Outdoor dimension Unit/Packing (WxDxH) mm 950×370×1350/1090×480×1500 950×370×1350/1090×480×1500 950×370×1350/1090×480×1500
Outdoor weight Net/Gross kg 125/135 125/135 125/135
Type R410A R410A R410A
Refrigerant
Charge g 5000 5000 5300
Liquid side/Gas side mm 9.52/19.05 9.52/19.05 12.7/19.05
Refrigerant pipe Max. refrigerant pipe length m 75 75 75
Max. difference in level m 30 30 30
Operation temperature range ℃ 16-30 16-30 16-30
Ambient temperature range ℃ 10~52 10~52 10~52
Qty’per 20’& 40’&40HQ Set 21/41/48 21/41/48 21/41/48