Data sheet for SINAMICS S120
Article No. : 6SL3300-7TE32-6AA1
Client order no. : Item no. : Figure similar
Order no. : Consignment no. :
Offer no. : Project :
Remarks :
Electrical data General technical specifications
Input Power loss (50 Hz 400 V)2) 2.2 kW
Number of phases 3 AC Power loss (60 Hz 460 V)2) 2.2 kW
Line voltage 380 - 480 V
Ambient conditions
Bypass contactor included Yes
Type of cooling air cooled
Rated data Cooling air throughput 0.24 m³/s (8.48 ft³/s)
Power requirement (DC 24 V) 0.17 A
Connections
Control current (when switching on
1.25 A Line side
230 V AC)
Switching current (when operating 230 Design Flat connector for M10 screw
0.6 A
V AC)
Number of connections 2
Short-circuit strength1) 10,500 A
Conductor cross-section 185 mm² (AWG -5)
DC link capacitance 41,600 µF
PE conductor
Mechanical data Design M10 nut
Degree of protection IP20 / UL open type Number of connections 2
Type of construction Chassis Conductor cross-section 185 mm² (AWG -5)
Frame size FI
Net weight 135 kg (297.62 lb)
Dimensions
Width 325 mm (12.8 in)
Height 1,400 mm (55.12 in)
Depth 355 mm (13.98 in)
1)
Current required for reliably triggering protective devices.
2) The specified power loss represents the maximum value at 100% utilization. The value is lower under normal operating conditions.
Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 1 Generated Mon Oct 14 04:19:58 CET 2024