OPENMARK VET Specification
OPENMARK VET Specification
I. Magnet system
Magnet Parameters
Shimming
www.anke.com 1
Shenzhen Anke High-tech Co., Ltd.
Gradient performance
Resolution parameters
www.anke.com 2
Shenzhen Anke High-tech Co., Ltd.
Channels 4
• Head imaging
• Spine imaging
Clinical Applications • Abdomen imaging
• Pelvis imaging
Channels 2
• Head imaging
• Spine imaging
Clinical application
• Abdomen imaging
• Pelvis imaging
S-Vet Coil Coil type Phased array receiving coil
Channels 2
www.anke.com 3
Shenzhen Anke High-tech Co., Ltd.
Vet coil – Extra Large Coil type Phased array receiving coil
Channels 4
• Head imaging
• Spine imaging
Clinical application
• Abdomen imaging
• Pelvis imaging
Head coil Coil type Phased array receiving coil
Channels 4
Channels 2
• Neck imaging
Clinical application
• Joints imaging
9-Inch Flex Coil Coil type • Single receiving coil
Channels • 1
Neck imaging
Clinical application
• Joints imaging for large animals
Channels • 1
• Neck imaging
Clinical application
• Joints imaging for small animals
1) All the Optional coils are not included in the standard offer, please contact to ANKE for future information about technology and
price.
www.anke.com 4
Shenzhen Anke High-tech Co., Ltd.
Patient communication
www.anke.com 5
Shenzhen Anke High-tech Co., Ltd.
V. Console system
Host computer
RAM ≥ 16GB
Image storage capacity (256×256 Matrix, uncompressed) Approx. 4,000,000 (256 × 256)
www.anke.com 6
Shenzhen Anke High-tech Co., Ltd.
SSFSE (Single Shot Fast Spin Echo) 2D/3D, combined with Half-Fourier Acquisition
technology, reduce the scanning time.
IR (Inversion Recovery)
STIR (Short Time Inversion Recovery) provide a good quality fat suppression imaging.
FLAIR (Fluid Attenuated Inversion Recovery) combined with fat suppression
technology, to provide a good quality T1 and T2 FLAIR imaging.
DIXON (Water and Fat Separation) technology to provide good quality of fat, water, in-
phase and out of-phase imaging.
Gradient Echo GRE (Gradient Echo) 2D/3D combined with Spoiled technology
sequences
GRSCOUT can provide single & multi slices three-dimensional positioning imaging.
GREDE (Gradient Echo with Dual Echo) 2D/3D, GREDESP (Gradient Echo with Dual
Echo with Shared Phase) 2D/3D for in-phase/out of-phase imaging
GREME (Gradient Echo with Multi Echo) 2D/3D, for high contrast T2 weighted
imaging, can effectively suppress flow artifacts of CSF and blood
TFE (Turbo Field Echo) 2D/3D/4D for abdominal imaging during free breathing, and
fast 3D/4D dynamic contrast imaging.
IRGRE (Inversion Recovery Gradient Echo) 2D/3D, can be used for neurology imaging
to increase the contrast between white matter and gray matter.
Echo Planar EPI (Echo Planar Imaging) with Single Shot and Multi Shot technology for high definition
sequences diffusion weighted imaging.
www.anke.com 7
Shenzhen Anke High-tech Co., Ltd.
Scanning process
Flow compensation technology Can effectively compensate for image artifacts caused by
liquid flow.
PROP (Periodically Rotated Overlapping Improves image quality by rotated data filling in K-space to
Parallel) data filling technology correct the effects of motion during MR sequence
www.anke.com 8
Shenzhen Anke High-tech Co., Ltd.
acquisition.
Gating trigger technology Use the Respiratory gating to perform triggered scanning,
can accurately suppress image artifacts caused by
physiological motion.
Breath-hold scanning technology K-space share technology combined with patient breath-
holding to achieve fast breath-hold scanning, which can
effectively improve the success rate of examination.
www.anke.com 9
Shenzhen Anke High-tech Co., Ltd.
www.anke.com 10
Shenzhen Anke High-tech Co., Ltd.
• TOF 3D MR angiography
• TOF 2D MR Venography
• MTC (Magnetization Transfer Contrast) technology and TONE (Tilted
Optimized Non-saturation Excitation) pulse to improved Contrast to Noise
Ratio of images
• MIP, MinIP and MPR reconstruction software
www.anke.com 11
Shenzhen Anke High-tech Co., Ltd.
VIII. Installation
Radio frequency shielding
Magnetic shielding5)
For additional reduction of the magnetic fringe field, suitable iron shielding can be installed in the walls of
the examination room. The room shielding can be used to create a magnetic shielding enclosure
Power Requirements
Power consumption
Stand-by ≤1 kW
5) The implementation plan of magnetic shielding depends on the condition of customer’s site, for more information, please refer to
the site planning manual.
www.anke.com 12
Shenzhen Anke High-tech Co., Ltd.
Equipment room
Scanning room
Operation room
www.anke.com 13
Shenzhen Anke High-tech Co., Ltd.
Address: Block B, LingYa Industrial Zone, Tangtou No.1 Road, Bao'an Twitter: ANKE (@ankeint)
District, Shenzhen, 518108, P.R. China
Facebook: ANKE (@ankemri)
Tel: +86-755-21622518 26688889
Fax: +86-755-26695307 26685908 Instagram: ANKE (@ankemarcom)
Email: [email protected] Linkedin: Shenzhen Anke High-tech Co., Ltd.
Website: www.anke.com
Specifications and appearance of the equipment may change without prior notice. ANKE reserves the right of final interpretation.