ARCHITECTURAL
ARCHITECTURAL
A02
GROUND FLOOR PLAN
ROOF DECK PLAN DISTRICT / CITY / MUNICIPALITY
SCHEDULE OF DOORS AND WINDOWS
RECOMMENDING APPROVAL:
A03
FRONT ELEVATION
HEAD ARCH'L. SECTION DATE
RIGHT SIDE ELEVATION
APPROVED:
REAR ELEVATION
LEFT SIDE ELEVATION
BUILDABLE AREA SECTION THRU-A BUILDING OFFICIAL DATE
SECTION THRU-B
LAND USE AND ZONING
A04
FLOOR FINISH LAYOUT
A05
WALL FINISH LAYOUT
A06
REFLECTED CEILING PLAN
CEILING DETAIL LINE AND GRADE
A07
CEILING DETAIL
SPOT DETAILS
A08
SPOT DETAILS
ARCHITECTURAL
5
N 88° 36' E 30.00 M 6
S01
GENERAL NOTES
TYPICAL DETAILS
2
2
1
3
S02
FOUNDATION PLAN
ROOF DECK FRAMING PLAN
DETAILS
4 3
STRUCTURAL
S03
FENCE FOUNDATION PLAN
31.56 M
TYPICAL DETAILS
34.08 M
E1
S 01° 22' E
LOT 11-A-1 LIGHTING LAYOUT
TOTAL LOT AREA = 972 SQM. POWER LAYOUT
N 01° 24' W
SANITARY
SCHEDULE OF LOADS AND COMPUTATION
LINE DIAGRAM
LOT 11-A-1
POINT
1-2
BEARING
S 88° 36' W
DISTANCE
20.00 M
P1 LEGEND
2-3 S 01° 24' E 2.50 M
GENERAL NOTES
3-4 S 88° 30' W 9.98 M
4 4-5 N 01° 24' W 34.08 M
1 CLEAN-OUT DETAILS ELECTRICAL
5-6 N 88° 36' E 30.00 M
6-1 S 01° 22' E 31.56 M LEGEND
TOTAL LOT AREA = 972 SQM.
SAN MIGUEL GREASE TRAP DETAILS
MUNICIPAL HALL
SANITARY LAYOUT
AD
ECE
4
1 S 88° 36' W 20.00 M
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
RECOMMENDING APPROVAL:
DRYING AREA
LAUNDRY
DIRTY KITCHEN HEAD ARCH'L. SECTION DATE
APPROVED:
DISPLAY
MASTER' BEDROOM BUILDING OFFICIAL DATE
COUNTERTOP
T&B
WORK TABLE
LEGEND
BEDROOM 03
WALK-IN-CLOSET
150MM THICK WALL
(4" CHB)
STUDY TABLE
T&B
STUDY TABLE
DINING AREA
200MM THICK WALL
BEDROOM 04
(6" CHB)
STORAGE
LIVING AREA BEDROOM 01
SUMMARY OF AREAS:
ROOF DECK SLOPE ROOF DECK SLOPE ROOF DECK SLOPE
CARPORT = ±29.0 SQM
CARPORT
SHOE RACK
STUDY TABLE
PORCH = ±14.4 SQM
LIVING AREA = ±23.46 SQM
POWDER
ROOM DINING AREA = ±14.43 SQM
KITCHEN = ±10.92 SQM
BEDROOM 02 MASTER' BEDROOM = ±16.62 SQM
MASTER' BEDROOM T&B = ±4.50 SQM
PORCH BEDROOM 01 = ±14.65 SQM
BEDROOM 02 = ±10.40 SQM
BEDROOM 03 = ±13.96 SQM
BEDROOM 03 = ±13.96 SQM
BEDROOM 03 & 04 T&B = ±4.68 SQM
POWDER ROOM = ±1.52 SQM
STORAGE = ±4.68 SQM
DIRTY KITCHEN = ±10.44 SQM
LAUNDRY = ±3.52 SQM
COMMON AREAS = ±33.86 SQM
TOTAL FLOOR AREA = ±225.00 SQM.
RECOMMENDING APPROVAL:
APPROVED:
BEDROOM 01 DIRTY
T&B
KITCHEN
CARPORT
LIVING AREA
RECOMMENDING APPROVAL:
APPROVED:
LEGEND
T-300/600
PCR DRYING AREA
T-300/600 300X600 mm CERAMIC TILES
WALK-IN-CLOSET
FINISH
T&B
T-600
DINING AREA W T-300/600 ROUGH PLAIN CEMENT
PCR FINISH
PCR
PCR
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
RECOMMENDING APPROVAL:
APPROVED:
LEGEND
LATEX PAINT
PL (SEMI-GLOSS)
LAUNDRY
DIRTY KITCHEN
PLEXIBOND IN WALLGUARD
PPW PL PPW PPW FINISH AS TOP COAT
KITCHEN
PPW SS SYNTHETIC GREY STONE
PL MASTER' BEDROOM
T&B
NOTE:
BEDROOM 03 WT INTERIOR PAINTING:
WALK-IN-CLOSET
LATEX SYSTEM :
· Inspect all surface to be painted for defects &
T&B should be corrected before starting work.
PPW DINING AREA
PL · Allow at least 2 weeks curing time before any
WT application.
PL · Cleaning & washing of concrete surface before
PL PPW PPW applying any paint.
PPW PPW · Apply concrete neutralizer, use Boysen (Plain
BEDROOM 04 PL
STORAGE
EP H
DISTRICT / CITY / MUNICIPALITY
LAUNDRY
H RECOMMENDING APPROVAL:
H H
APPROVED:
CHANDELIER
SQUARE LIGHT
WL WALL LAMP 8W
GL GARDEN LIGHT
CEILING VENT
NOTE:
FIBER CEMENT BOARD
· Use4.5 mm thk. Fiber Cement board for
ceiling w/ metal framing 600 X 600 space
B.W.O.C
· Use Epoxy w/ joint mesh as joint sealer.
· 1 coat Boysen Acrytex Primer (Plain Roller)
· Use Skimcoat until wall becomes relatively
plain and smooth
· 2 coats Flat Latex as final paint applied
using roller.
EXPOSED W/ PAINT CONCRETE
· Exposed concrete areas w/ paint apply
Boysen concrete neutralizer, (Plain Roller),
leave the surface overnight to cure.Wash
surface using clean water.Patch all
temperature cracks, corner joints using
Epoxy.1 coat Boysen Acrytex Primer (Plain
Roller).1 coat Boysen Flat Latex (Plain
Roller).2 coats Boysen Top Coat any choice
of color (Plain Roller) to be approved by
Architect.
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
RECOMMENDING APPROVAL:
APPROVED:
LEGEND (FINISHES)
DROP LIGHT
CHANDELIER
SQUARE LIGHT
WL WALL LAMP 8W
GL GARDEN LIGHT
CEILING VENT
NOTE:
FIBER CEMENT BOARD
· Use4.5 mm thk. Fiber Cement board for
ceiling w/ metal framing 600 X 600 space
B.W.O.C
· Use Epoxy w/ joint mesh as joint sealer.
· 1 coat Boysen Acrytex Primer (Plain Roller)
· Use Skimcoat until wall becomes relatively
plain and smooth
· 2 coats Flat Latex as final paint applied
using roller.
EXPOSED W/ PAINT CONCRETE
· Exposed concrete areas w/ paint apply
Boysen concrete neutralizer, (Plain Roller),
leave the surface overnight to cure.Wash
surface using clean water.Patch all
temperature cracks, corner joints using
Epoxy.1 coat Boysen Acrytex Primer (Plain
Roller).1 coat Boysen Flat Latex (Plain
Roller).2 coats Boysen Top Coat any choice
of color (Plain Roller) to be approved by
Architect.
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
RECOMMENDING APPROVAL:
APPROVED: