Project
Proposal
System Size
6 KW On Grid System with net metering
Prepared For
Mr. Sheraz
Prepared By Quotation Number Submission Date Valid Until
Engr. Abdul Hadi 4754 Oct 22 ,2024 Nov 10 ,2024
Quotation: 4520
About Us
Pantera Energy is one of the pioneer solar energy solution providers in Pakistan. Innovation and intelligence are
the core essence of our solar energy management systems for residential, commercial, industrial and
agricultural sectors. We have a diverse range of products and services with proven expertise in providing state-
of-the-art solar energy systems. With a network of regional teams and partners, Pantera Energy enjoys a
nationwide presence.
Mission
We strive to build an Eco Friendly and sustainable world using technology and innovation to build communities
that are responsible about environmental protection.
Vision
To make reliable and high quality renewable energy systems affordable and accessible for everyone
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
Certifications & Licences
SECP Certification
Securities Exchange Comission of Pakistan
Certificate of Incorporation
Pantera Energy Pvt. Ltd.
PEC License
C3 Category
Pakistan Engineering Council
EE04 - EE06 - EE09 - EE11(Solar) - EE11(Solar Energy System) -
EE11(General Electrical Works)
Pantera Energy Pvt. Ltd. (Licensee)
AEDB Certification
V1 Certification
Alternative Energy Development Board
Ministry of Energy (Power Division)
Vendor | Installer | Service Provider
Pantera Energy Pvt. Ltd.
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
S u p p ly & Installatio n o f P an tera E n erg y
Intelligent Solar Energy Management System
Date: 2024-10-22
Dear Sir,
T hank you for giving P antera E nergy an opportunity to subm it financial and engineering proposal.
T h e c o s t o f e le c tric ity fro m n a tio n a l p o w e r g rid s k e e p s g o in g u p , a n d th e im p o rta n c e o f m a in ta in in g
e n v iro n m e n t g ro w s e v e ry d a y. In s ta llin g a s o la r e n e rg y s y s te m is a c o s t-e ffe c tiv e , s u s ta in a b le , a n d s
t o re d u c e y o u r e n v iro n m e n ta l fo o tp rin t a n d y o u r e n e rg y bgut edW . e k n o w y o u c a r e a b o u t th e n a tu
e n v iro n m e n t a s m u c h a s w e d o . S o la r e n e rg y is n o n -p o llu tin g a n d re n e w a b le . In a d d itio n , y o u r n e w s
o ffs e t y o u r c a rb o n fo o tp rin t b y 2 0 to n s o f C O 2 , e q u a l to p la n tin g 3 5 A c re s o f tre e s .
W e w ant to save e lectricity b ills a n d m an a g e yo u r en e rg y resource s so yo u alw ays h a ve th e h ig h est ava
o f ene rg y a t the lo w est p ossib le co st. W ith th e in te llig e nt so la r en e rg y m a nag e m e n t system , yo u can g e
n o isy g enera tors, inefficie n t U P S a n d e n joy a n u n inte rrup te d p ow e r sup ply d a y a n d n ig h t.
The Intelligent E nergy M anagem ent System has IntelliSEN SE Intelligent E nergy S oftw are, w hich allow s
system to further reduce the electricity bill to ZER O . W ith the net m easurem ent package, IntelliS EN SE
you to sell the netw ork’s surplus.
The Pantera Energy Intelligent Solar Energy M anagem ent com es with a 5-year warranty on the entire syste
including inverters com pared to othe r conventiona l sola r system s tha t has only 1-yea r warranty fo r thei
inverters.
W e hope to help you get m ore energy independence by providing a good investm ent for the com ing years an
helping you m ake a m ore positive im pact on the environm ent.
Thanks & Regards,
Engr. Abdul Hadi
Technical Sales Engineer
0301-8420442
[email protected]Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
Executive Summary
6kW
Total PV Capacity propose
600 ft2
Require total unshaded area:
Canadian Solar 580/585W - BIFACIAL N TYPE TOPCON Module
Maintenance free, IP65 rating for Inverter
Pantera IntelliHUB System for remote monitoring
Aluminium Standard Type Structure with Stainless Steel Nut Bolts XLPE/
PVC Tin coated copper wire for PV strings
Disconnect Switch with 4mm 2 wire
AC SPD for Surge Protection
Special Emphasis on reducing the ohmic losses
Annual average energy yield will be 7300 kWh
Annual savings: PKR 2,92,000/- @ PKR 40/kWh
Payback period of the system is 4 years
Installation time: 18-20 Days after advance payment.
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
6
Quotation: 4520
Single Line Diagram
Mdule Specifications
11 x 580W
580W
STC Rating
Vmp 36.76V
Voc 48.5V
Imp 11.59A
Isc 11.59A
Wire Schedule
DC 4mm2
AC As per design
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
Financial
Proposal
6kw On-Grid system without Inverter and with net metering
System
Sr No. Description Qty Unit
1 Solar Panels 11 No.
T
Canadian Solar 580W - BIFACIAL N TYPE TOPCON
2 Inverter 0 No.
3 Distribution Box 1 No.
AC and DC Breakers with AC SPD's
4 Structure Type 11 No.
Aluminium Structure for standard
5 DC wire 1 No.
4mm2 XLPE/PVC, Tin coated wire to interconnect the Inverters and Solar Strings
6 AC wire 1 No.
AC wire from inverter to Distribution Box
7 Transportation 1 No.
Delivery of equipment from warehouse to site
8 Installation 1 No.
Labour, Civil works, and Etc.
9 Earthing 1 No.
Grounding Bore, Grounding wire
1
10 Net-Metering No.
Net Meter Installation & All Dealings with respective DISCO
PKR 650,000/-
Total Amount for cash only(PKR) after discount
Note:This Quotation is quoted with standard Structure.
Any Customizations will changethe price.
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
Warranty
Item Description
ASTRO ENERGY/Canadian Solar/Jinko Solar/Longi Solar * 12/25 Years
Goodwe (Excluded) ** 5 Years
Comprehensive Warranty with Structure and Distribution Box 1 Years
* 10 years 90% output and 25 years 80% output Linear Warranty
** 5 Years Warranty according to the warranty sheet of Goodwe
Terms and Conditions
Prices are valid until Nov 10, 2024
Price Validity
Payment Terms 80% advance and 20% after installation
Delivery 18-22 working days after confirmation of order
2 years of free O&M from Intellihub
O&M
Up to 10 site visits will be free during O&M period
Complete Installation
Transportation
Scope of Work Included
Loading and Unloading of equipment
Civil Works & mounting structures
Scope of work not Increase of sanctioned load on Electricity Bill
Name change on Electricity Bill
included Purchase of MDI Meter (if required)
License fee of Nepra
Net Metering Scope Purchase of Whole Current Meter
Documentation and all DISCO related dealings
This offer shall be subjected to standard force majeure conditions such as the
supplier will not be held responsible for any damage due to Acts of God, War,
Force Majeure
riots, Civil Commotion/s strikes lookout or disturbance directly affecting the
supply over which supplier has no control.
Customer Signature
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
Payback Period
Average daily unit generated by 1kW: 4.0 kWh
Average daily unit generated by 5 kW: 20 kWh
Average annually unit generated by 5.1 kW: 7,300 kWh
Unit rate as calculated from bill: PKR 40/kWh
Annual Saving in electricity bill: PKR 2,92,000/-
Payback Period comes at approximately 3.2 Years
Increase in electricity tariff will result in even lower payback period
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
10
Technical Proposal
Pantera Energy IntelliPHONE
Salient Features Details
Brand Pantera Energy
Connects through Pantera Energy Cloud
Real time system monitoring
Alerts, faults and warning data display
Features
Integrated to your smart home applications and can act as a
hub of your smart home environment by communicating and
controlling all of your smart appliances and System
Statistics - System Parameters, PV predicted values,
forecasted values, load data, net-metering and data control
Pantera Energy INTELLIHUB
Salient Features Details
Brand Pantera Energy
All systems are cloud connected
Remote diagnostic and repair
24/7 continuously monitored and controlled by technical
staff
Features
Our dedicated team is available at all times to ensure that
your system keeps operating properly and provides you with
any assistance you might need
String Level Monitoring
Troubleshooting Mechanism
By using our remote monitoring system, we are able to see each and every parameter of our system i.e. PV
Power Generation, AC Output Power, System Effciency, and etc. Our Intellihub system gives us notification
about the faults like Lower Effciency, Grid Loss Failure, Wi-Fi Disconnectivity, etc. Our dedicated team analyze
the nature of fault and report it to the Aftersales Services Department, where a team of technical staff visit site
and clear the fault as soon as possible within 24 Hours
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
11
Component Specification
Product Description Brand Specification
Canadian Solar
PV Modules 580/585W - BIFACIAL N type
Structure Local
AC Cables Newage/Fast/Equivalent 4C, 450/750V AC 4mm 2
4mm Single Core, XLPE/PVC, Tin
DC Cables Newage/Equivalent
Coated 1000V DC
AC Breakers Chint/Equivalent 3 Pole, As per design
DC Breakers Chint/Equivalent 4 Pole, 16A
Nut Bolts Imported Stainless Steel, Grade 304
Distribution Box Local Polycarbonate
Residual Current
Built-In Integrated
Monitoring
Surge Protection Device Built-In Integrated, Type II
MC4 Connectors QC Solar/Equivalent IP 68
Ducts, PVC Bends & Adam
UPVC/PVC
Pipes, U Clamps Jee/Popular/Equivalent
Black, Nylon, UV Resistant, 310 x 4.8
Cable Ties KSS/Equivalent
mm
Civil Work Local As per design
Disconnect Switch Chint/Equivalent 4 Pole, 100A
Net Meter DISCO Approved Whole Current
Earthing Wire Local 16 mm2 Cu bare conductor
Bentonite powder, Gypsum & Sodium
Earthing Powder Local
Sulphate
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]
Quotation: 4520
12
Clients
Head Office: 12A-XX, Khayaban-e-Iqbal, Islamabad Office: EOBI House, Mauve Area, UAN: 042-111-112-886 | 051-111-112-886
DHA Phase 3, Lahore G-10/4, Sirinagar Highway, Islamabad [email protected]