Instruction Manual
Please read the entire instruction manual (include Safety Precaution) thoroughly before operation.
Safety Precaution *Please keep this instruction manual at your side after you read.
Observe all warnings and cautions; it is extremely important and any safety serious contents are described.
Expression and meaning are as follows.
Warning When you use FGJN wrongly, it may cause serious problem, such as death or severe injury.
Caution When you use FGJN wrongly, it might cause serious problem depend on the situation.
Warning
Please be careful to the flying apart Do not use scarred hook or deformed
of the test substance. hook.
At the breakdown test or break test, you might
They might be broken or slip. Heavy test
get injury due to the flying apart of the objects.
substance might hit your hoot.
Please wear the mask for the protection, and
pay proper attention to safety.
Caution
Caution
Please use only supplied AC adapter Do not charge and use the FGJN other
for charging. than AC 100 - 230V.
If you use non-supplied AC adapter, electronic
circuit might be broken, and fire break might happen. Become the source of fire disaster and electric shock.
Please plug the AC adapter in firmly. Do not touch the AC adapter with wet
hand.
When it is loose, short out and electric shock, and
then it might be fire hazard. There is the threat of electric shock.
Do not take down, repair, and make Do not pull the code to unplug the AC
We recommend the force gauge to be checked Please operate the force gauge within
and calibrated regularly. Though it is depend on operating humidity range; 35 ~ 85RH.
the frequency of use and loading, the accuracy of
If you use the force gauge beyond the above range,
measurement will be declined with time.
it might produce improper operation.
PEAK ZERO
MEM
UNIT
MEM MEM
UNIT UNIT
PEA
K
ZE
RO
ME
UN M
IT
-3-
1.Product Features
● Nickel –hydrogen battery enable us to use long time
→ 4.1. Charge
● One touch shimple operation for changing the unit N, kg(g), Lb(oz).
→ 5.3. Change display unit
4. Measuring adapters
M6 adapters are included with other types.
-4-
3. Part names and functions
3.1.Main Unit
① Sensor shaft
② Display
③ PEAK key
⑤ZERO key
④UNIT key
⑨ Threaded hole
⑥POWER key
Model number
⑦ AC adapter port
⑧ Hanger attachment bolt
-5-
3.2.Display
3.2.1.Part names
Display of unit
3.2.2.Numeric Display
Display the measuring value with sign and 4 digits numbers. Compression force: plus, Tension force: minus.
(It’ s available to switch plus/minus with the setting of function (f01)).
Reverse display is available.
3.2.3.Unit Display
Display the units. In case of overload, “OVR” is shown. “PWR” appears to notify that there is 1 minute before power off.
Newton Kilogram Gram Pound Ounce
Display of unit
1 minut before
Overload
power off.
-6-
4.Before use
4.1.Charge
Do not charge with non- Please use AC adapter which supplied with FGJN. If you use non-attached AC
adapter, electronic circuit might be broken and fire might happen.
attached AC adapter.
Before the FGJN arrive at your hand, nickel hydride battery might discharge electricity.
Please plug attached AC adapter and charge before you use.
② The nickel hydride battery is charged automatically when it
is discharged during the usage of AC adapter.
※ If you charge the battery frequently, its lifetime will be shorten.
When you use the FGJN with AC adapter, you should not insert and
remove the AC adapter often.
Hook
Flat head Cone head Notched head Chisel
PEAK ZERO
Extension rod
4.3.Attaching hanger
Please attached the hunger according to need.
-7-
4.4.Tracking
A load cell of strain gauge is used for FGJN as a load sensing. By using this sensor, the measuring value is slightly changed due to temperature
and so on, but tracking is able to cancel this slightly change by the software. When you measure very minute forces, measuring value error
might happen due to the tracking. In this case, you may turn off the tracking function.
When the power off, while hold down the PEAK key and UNIT key simultaneously, press and release the POWER key (release the PEAK key and
UNIT key after the value is appeard in the display more than 1 second), you can switch the tracking ON/OFF.
PEAK ZERO
Tracking ON Tracking OFF
①
UNIT POWER ②
4.5.Function setting
The following setting items in function mode.
Item Unit Set contents Default factory setting
Display sign f01 -0001(minus), 0001 (plus) 0001
Display update time f02 1、 2、 3、 5、 10、 20 (times/second) 3
Auto power off f03 10 (10 minutes )、 oFF (not valid) 10
PEAK ZERO ①
J
UNIT POWER ②
PEAK ZERO
UNIT POWER
-8-
4.5.1.Sign: f01
It’ s available to set the sign (plus or minus) of measuring value for pushing the sensor shaft.
Select the sign by use of UNIT key / Press the PEAK key to move ahead.
Key operation Display
Minus Plus
PEAK ZERO
UNIT POWER
ZERO Register the all setting, and then move to the standard measuring mode.
UNIT POWER
ZERO Register the all setting, and then move to the standard measuring mode.
※ There is no key operation, RS-232C communication, USB communication, change of measuring value.
UNIT POWER
ZERO Register the all setting, and then move to the standard measuring mode.
-9-
4.5.4.Function mode-end
Press ZERO key to memorize the set value and come back from function mode to standard measuring mode.
In order to cancel the change of function mode, press POWER key, then turn the POWER off.
① ②
① Hold down UNIT key Display force gauge model Standard measuring mode
② Press POWER key.
J
UNIT POWER
Turn POWER off. Press ZERO key and hold, then press POWER key and release (release
ZERO key after the value is appeared in the display more than 1 second).
ZERO Function mode;
Function mode
POWER UNIT : Change the setting content
PEAK : Switch the function
ZERO : Register the setting content
UNIT Turn POWER off. Press UNIT key and hold, then press POWER key and release (release
Reverse display
POWER the UNIT key after the value is appeard in the display more than 1 second.)
-10-
5.2.Measuring Mode
There are standard measuring mode and peak hold mode in the measuring mode.
PEAK ZERO J
UNIT POWER
UNIT POWER
Under the plus peak hold mode and minus peak hold mode, press ZERO key to clear the peak value (Tare is not performed).
5.4.Tare
Press ZERO key to reset the measuring value. Please press the ZERO key before starting the measurement in order not to change the starting
display value because of the own weight or measuring direction or weight of measuring fixture.
Measuring range is from maximum pulling load to maximum compression load. When measuring range is over, “OVR” is displayed.
Press the ZERO key under the plus peak hold mode or minus peak hold mode, plus peak value or minus peak value is cleared. At the plus peak
hold mode and minus peak hold mode, tare does not performed even if press and release ZERO key.
When turning POWER on, tare is automatically performed (if you turn POWER on during the getting load, display becomes “0” and you cannot
measure accurate value).
5.5.Overload
”OVR” shows on the LCD when the load exceed 120% of the capacity (tare value is not included ).
Please reduce the load immediately. OVR
-11-
6.Frequently –asked questions
-12-
7.Support
7.1.Repair and Calibration
We have calibration service for value. We recommend calibrating regularly for keeping up the accuracy of force gauge. Please ask our dealers for
the price and lead time of the calibaration.
7.2.Warranty
NIDEC DRIVE TECHNOLOGY CORPORATION. warrants, to the original purchaser of new products only, that this product shall be
free from defects in workmanship and materials under normal use and proper maintenance for one year from the date of original purchase.
-13-
8.Specifications and Dimensions
Dimensions
26 26
70°
70°
φ10
φ10
M6 M6
Flat head φ 12 Cone head : 70° Chisel : 70°
(43)
26 92
12 80
70°
φ6
φ10
R4
φ10
8
φ10
M6 M6
M6
3.5
M6
Notched head : 70° Extension rod L= 92
Hook
-14-
〈Web Page Information〉 Please scan the QR code or access the URL below.