MACH-ProView LCD
BACnet Controller
Elegant views of efficiency
The Reliable Controls MACH-ProView™ LCD is a powerful
and elegant BACnet Building Controller (B-BC) and
BACnet Operator Display (B-OD) that provides a plenitude
of attractive, high- resolution graphical interfaces to
access, control, and monitor the comfort and energy of any
space.
RE LI AB LE C O N T RO LS . C O M / MPV- L
MACH-ProView LCD
P RO DUCT FEATURES
Protocols Large Touchscreen Display
l BACnet l Display full-color graphics, runtime logs, trend logs,
l Supports one B/IP subnetwork and B/VPN.
alarms, and schedules.
l Ethernet or MS/TP.
l Configure display to be always on or to blank after
10-100 seconds of idle time.
l DHCP: Dynamic Host Configuration Protocol.
l SMTP: Simple Mail Transfer Protocol: Languages
l Provides standard email communications for l English.
broadcasting email alarms. l French.
l Supports TLS/SSL security. l German.
l SNTP: Simple Network Time Protocol. l Italian.
l Wi-Fi on controllers with the -W option: l Traditional Chinese.
l Supports WPA-Personal and WPA2-Personal security. l Portuguese.
l Spanish.
l SMART-Net.
32 Views 64 System Groups
l Group related objects on one display.
l Display and access related objects from the LCD.
l 320 unique objects per group.
l Customizable screens include EQUIPMENTview,
SPACEview, LISTview, and STATview. Six Inputs
l System Views include TRENDview, ALARMview, l Universal ranges.
SCHEDULEview, RUNTIMEview, CONFIGURATIONview,
l Use software to select thermistor/dry contact, 4–20 mA,
and NAVIGATIONview.
or 0–10 VDC.
Support for myControl App Six Outputs
l Display SPACEview, LISTview, and STATview using the
l First four have jumper-selectable universal ranges.
myControl app.
l Last two are binary solid-state relay only.
l The MACH-ProView allows 10 concurrent myControl app
users. 64 Loops
Optional Inputs l Standard P, PI, or PID controllers for closed loop control.
l CO2 sensor. 64 Calendars
l Humidity sensor. l Designate days of the year as holidays.
l Occupancy sensor. Single-point Trend Logs
l VOC sensor with humidity sensor.
l Record values at user-defined intervals or based on
512 Values change of value.
l Select standard and custom ranges as well as fixed l Dynamic; user assigned.
program-driven values. 129 Notification Classes
32 Schedules l Specify alarm configuration, broadcast destination, and
l 14 on/off times for each weekday or exception. email recipients.
Multipoint Trend Logs 64 Programs
l Store up to eight objects in each trend log. l Freely programmable control strategy in a readable,
BASIC-like language.
l Record values at user-defined intervals.
l 3,200 bytes per program.
l Dynamic; user assigned.
Runtime Report Onboard Temperature Sensor
l Dedicated 10 kΩ thermistor.
l Total the on time and record the on/off times of every
binary object. SMART-Net Port
l Automatically generated. l Network up to four SMART-Net devices.
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
P RO DUCT FEATURES
128 Arrays 24 Custom Units
l Up to 128 elements in a one-dimensional array. l Eight analog engineering units.
20 Tables l Eight binary units.
l Eight multistate units with eight states, 30 characters
l For creating custom scaling functions.
each.
128 User Passwords 256 Net Ins
l Protect access to the system.
l The maximum number of shares from other devices.
l Assign each user with a username and access level.
l Multiple levels of security. 128 Net Outs
l The maximum number of writes to other devices.
Warranty
l 5 years. Real-Time Clock
T ECHNICAL SPECIFICATIO NS
Processor Memory
l 147 MHz high-performance 32-bit embedded l 8 MB operating RAM.
microcontroller. l 1 MB nonvolatile RAM for trends and dynamic values.
Supply Voltages l 32 MB Flash EEPROM operating system, database, and
controller configuration.
l 24 VAC ±10% 93 VA maximum, 50/60 Hz.
l 24 VDC ±10% 9 W maximum. Communication Options
Display l One IEEE 802.3 (Ethernet 10/100BASE-T).
l One IEEE 802.3af (PoE).
l Full-color 480 x 272 pixel screen.
l One IEEE 802.11 a/b/g/n (Wi-Fi, 2.4/5.0 GHz).
l 4.3" wide-quarter VGA.
l One EIA-485 (RS-485) port that supports a baud rate up
l Thin film transistor.
to 76.8 kbps.
l Projective capacitive touch.
l One SMART-Net port that supports up to four devices
l Display area 57 x 96 mm (2 1/4" x 3 3/4"). on a SMART-Net network.
Universal Outputs Universal Inputs
l 12-bit D/A converter. l 12-bit A/D converter.
l Analog: 0–12 VDC. l Analog: 0–10 VDC 4–20 mA, thermistor.
l Binary: Software-configurable between 0–12 VDC. l Binary: Dry contact.
l Maximum 75 mA each. l Impedance:
l 24 VAC overvoltage and short protection. l 1 MΩ for 0–10 VDC range.
Solid-State Relay Outputs l 250 Ω for 4–20 mA range.
l Switch 24 VAC/VDC. l 20 kΩ pull-up for thermistor/dry contact range.
l 500 mA maximum. l Pulse counting up to 150 Hz. Supports flow meters.
Temperature Sensor l 24 VAC overvoltage protection.
l Range -20°C to 55°C. CO2 Sensor (-CO2 Option)
l 0.1°C (0.18°F) resolution. l Nondispersive infrared optical sensor.
l User calibrated to ±0.1°C (0.18°F) accuracy. l 400-2,000 ppm range.
l Accuracy ±40 ppm.
l Automatic calibration built in.
l Nonlinearity <1% of full scale.
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
T ECHNICAL SPECIFICATIO NS
VOC Sensor (-V option) Occupancy Sensor (-OC Option)
l Automatic background calibration. l Passive infrared radiation sensor.
l Heated metal oxide sensor. l 64 detection zones.
l 0-8,190 ppb range. l 94° horizontal range/82° vertical range.
l Accuracy 40% of measured value. l 5 m (16.4 ft) maximum detection distance.
l Resolution: Wiring Terminals
l 2 ppb (0 to 2,008 ppb).
l 16–24 AWG (1.31–0.21 mm2).
l 6 ppb (2009+ ppb).
l Stranded or solid core.
l Automatically includes humidity sensor (-H option). l Copper conductors only.
Humidity Sensor (-H Option) Hardware Mounting Included
l 0.1% display resolution. l Two 6-32 1" Truss head Phillips mounting screws for
l 0%-100% range. single-gang and dual-gang boxes.
l Accuracy ±2.4% maximum from 0%–90%. See plot. Weight
Dimensions l 0.28 kg (0.6 lb).
l 14.5 cm L x 12.2 cm W x 2.7 cm H Ambient Limits
(5 11/16" L x 4 13/16" W x 1 1/16" H).
l Operating: -20°C to 55°C (-4°F to 131°F).
l Compatible with single-gang, dual-gang,
4" x 4", and 4 11/16" square boxes. l Shipping: -40°C to 60°C (-40°F to 140°F).
l Minimum opening in wall 46 x 72 mm l Humidity: 10%–90%.
(1 13/16" x 2 13/16").
Real-Time Clock
l ±1 second per day.
Memory/RTC Backup
l 72-hour backup.
l 10 years for database.
Certifications
l BTL Listed (B-BC).
l BTL Listed (B-OD).
l UL 916 Listed.
l FCC CFR 47 Part 15 Class B.
l CE.
l WEEE.
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
O RDERING
Models Build Your Order
MPV-L-M To create the order number, add options to the base
l MACH-ProView LCD with MS/TP connection. model. For example, MPV-L-E-CO2-H-OC/W is the order
number for a MACH-ProView LCD with Ethernet port and
MPV-L-E
CO2, humidity, and occupancy sensors in a white enclosure.
l MACH-ProView LCD with Ethernet port.
Order limitations are as follows:
MPV-L-P l -V option must be ordered with the -H option.
l MACH-ProView LCD with Power over Ethernet port.
Accessories
MPV-L-W ACC-MPV-L-PM
l MACH-ProView LCD with Wi-Fi connection.
l MACH-ProView Panel Mount Kit. Please note: If you
Options mount the controller with this accessory kit, onboard
sensors are not functional. We recommend against
l -CO2 adds CO2 sensor.
adding optional sensors or using the onboard
l -H adds humidity sensor. thermistor with this accessory.
l -V adds VOC sensor.
CC-MPV-XP2
l -OC adds occupancy sensor.
l Cable from MACH-ProView LCD controller to X-Port-2
l /W for white enclosure. Converter for local MS/TP communications.
P RO DUCT IMAGES
MACH-ProView LCD bottom
MACH-ProView LCD MACH-ProView LCD side
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
A PPLICATIO N DIAGRAMS
Wi-Fi network
MS/TP network
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
A PPLICATIO N DIAGRAMS
Ethernet or Power over Ethernet (PoE) network
H UMIDITY SENSO R CHART
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
I NTEGRATED EQUIPMENT VIEW S
EQUIPMENTview example 1
EQUIPMENTview example 2
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
I NTEGRATED EQUIPMENT VIEW S
EQUIPMENTview example 3
EQUIPMENTview example 4
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD
I NTEGRATED EQUIPMENT VIEW S
EQUIPMENTview example 5
SPACEview showing cooling setpoint
MPV-L • 08/26/21 • SG © 2021Reliable Controls Designed and manufactured in Canada
MACH-ProView LCD