Quiz [ FS 9500 L2 ]

You must receive a score of 75 % or higher on the quiz to corr Back Next
the course.
Started on Tuesday, September 3 , 2024, 11:31 PM
State Finished
Completed on Tuesday, September 3, 2024, 11:47 PM
Time taken 15 mins 37 secs
Feedback Congratulations, you passed the quiz!

Question1

Correct

Points out of 1.00

A client states that despite the technological advantages of


FlashCore Modules, they are required to use industry standard
serial-attach SCSI (SAS) and / or non -volatile memory express
(NVMe) solid - state drives (SSDs). They are trying to calculate
how much capacity they can put in the control enclosure. They
ask, “What is the largest drive capacity, and interface, they can
use? ” What is the correct response?

15.36TB SAS
15.36TB NVMe

30.72TB SAS
30.72TB NVMe V

©
Question 2

Correct

Points out of 1.00

Back Next

Clients have started asking a lot of questions about hardware -


based capabilities that are embedded in the hardware of each
IBM FlashCore Module 4 (FCM 4). What are three impressive
hardware- based capabilities that sellers can talk about?

Encryption, Compression, and Ransomware Threat


Detection
Deduplication, Compression, and Encryption
Compression, Ransomware Threat Detection, and
Safeguarded Copies
Ransomware Threat Detection, Safeguarded Copies,
Synchronous Replication

Question 3

Correct

Points out of 1.00

During meetings it has become clear that many clients are


confused about the differences between the 2 U FlashSystem
9200 and the 4U FlashSystem 9500. The confusion appears to
be related to the belief that there might be many controllers in
the 9500. Which comment below accurately reflects the
FlashSystem 9500?

Four,1U node canisters (controllers), with oneI/ O Group

Four, 1U node canisters (controllers), with twoI/ O Groups


Two, 2U node canisters (controllers), with twoI/ O Groups

Two, 2U node canisters (controllers), with oneI/ O v


Group

e
Question 4

Correct

Points out of 1.00

Back Next

In an effort to provide clients with greater flexibility, IBM


continually increases the number of snapshots that the
FlashSystem 9500 supports. What is the number of snapshots
that are supported on FlashSystem 9500 with Storage
Virtualize 8.6.0 or greater?

72,000

32,000
48,000

64,000

Question 5

Correct

Points out of 1.00

Flow many fibre channel (FC) switches are included with a


FlashSystem 9500 R ?

2
*

e
Question 6

Correct

Points out of 1.00

Back Next

A client is trying to understand why Safeguarded Copy (SGC) is


so useful. They seem to think the it is just a snapshot. What
can a well- informed seller tell them to help them appreciate
the value of SGC?

Immutable Safeguarded Copies of business- critical data


reside on tape for recovery but remain hidden from view,
therefore bad actors are unable to get to them.
Immutable Safeguarded Copies of business- critical V
data reside on the primary storage but remain hidden
from view, therefore bad actors are unable to get to
them. They can be used to recover very quickly.
Immutable Safeguarded Copies of business- critical data
reside on Ready Nodes for recovery but remain hidden
from view, therefore bad actors are unable to get to them.
Immutable Safeguarded Copies of business- critical data
reside on secondary storage for somewhat slow recovery
but remain hidden from view, therefore bad actors are
unable to get to them.

Question 7

Correct

Points out of 1.00

A client is planning on purchasing a FlashSystem 9500. They


wish to minimize their capital expenditure. What is the
smallest amount of cache they can purchase that will deliver
100 % memory bandwidth?

3072GB

4096GB
1024GB

2048GBV

O
Question 8

Correct

Points out of 1.00

Back Next

The FlashSystem 9500 and 9500 R have gained Secure and


Trusted Boot abilities as part of the enhancements to
enterprise robustness. How does Trusted Boot keep client ’s
data safe?

IBM uses Unified Extensible Firmware Interface (UEFI)


secure boot. UEFI secure boot is relatively simple
compared to trusted boot. The UEFI firmware has a
private key embedded in it.
The CPU is a root of trust. We have to trust that the Power
CPU itself has not been compromised.

Trusted boot uses functionality provided by the Intel


CPU, and the Trusted Platform Module (TPM) to verify
that the firmware, bootloader, and early boot
environment, are safe.
Trusted boot uses functionality provided by the Power
CPU, and the Trusted Platform Module (TPM) to verify that
the firmware, bootloader, and early boot environment, are
safe.

Question 9

Correct

Points out of 1.00

The FlashSystem 9500 comes with removable host bus


adapter (HBA) cages. What should sellers know, and make
sure clients are aware of, with respect to adding HBAs into the
cages?

They are able to be dissimilarly configured between


controllers
They take advantage of the PCIe Gen3 buses
They are Hot Pluggable
They are Cold Pluggable V

©
Question 10

Correct

Points out of 1.00

Back Next

IBM’s Policy - based high availability (PBHA) introduces a new


methodology. The methodology employs a feature that
contains a set of hosts, volume groups and volumes - and the
mappings between hosts and volumes. What is this called?

Storage partitions v»

Virtual partitions
vVols
VASA

Question 11

Correct

Points out of 1.00

A client asks what does the “R ” in FlashSystem 9500 R stand


for ? What is the correct answer?

RAID

Response Time

Rack
Replication

e
Question 12

Correct

Points out of 1.00

Back Next

A client is fascinated with the numerous software and


hardware data resilience abilities in the FlashSystem 9500.
They seem particularly interested in knowing which hardware
features are hot - pluggable. Which two items should a seller
indicate are hot - pluggable?

Batteries and Fans


Fans and Power Supplies

Boot Drives and Batteries

Boot Drives and Flost Bus Adapter (HBA) cages

Question 13

Incorrect

Points out of 1.00

During a client meeting, the seller is asked about the onboard


Ethernet ports in the FlashSystem 9500. Which statement
below is correct?

They are lOOGbE and are usable for both management


and Flost I/ O
They are lGbE and are for management only
They are lGbE and are usable for both management x
and Flost I/ O
They are lOGbE and are for management only

e
Question 14

Correct

Points out of 1.00

Back Next

IBM is beginning to promote a high -availability solution to help


improve performance, scaling, management and more. What is
the name of the feature?

SVC Stretched Cluster

HyperSwap

GlobalMirror
Policy - based HA

Question 15

Correct

Points out of 1.00

Clients seem fascinated by IBM’s Ransomware Threat


Detection in FlashCore Module 4s. It is important they realize
that to take advantage of the detection they must use IBM’s
powerful cloud software that provides AI based predictive
analytics and proactive health monitoring to handle alerts.
What is the name of the software they must use?

IBM Storage Insights Pro


IBM Storage Control

IBM Multicloud Manager


IBM Storage Connect

e
Question 16

Correct

Points out of 1.00

Back Next

A client is interested in using 64Gbs FC host ports in a


FlashSystem 9500. What is the maximum numbers of 64Gb
FC ports that can be configured in a 9500?

24

48 >/
32

64

Question 17

Correct

Points out of 1.00

What is the primary recommended RAID level for FlashSystem


9500 and FlashSystem 9500 R ?

Distributed RAID 1
Distributed RAID 5
Distributed RAID 6
Traditional RAID 6

e
Question 18

Incorrect

Points out of 1.00

Back Next

In a competitive situation a prospective client indicates they


will be consolidating numerous workloads and are concerned
about the maximum performance of the FlashSystem 9500.
Dell has provided them with PowerMax “ Hero Numbers ”
(maximum performance) and the client is now asking what is
the maximum performance “Hero Numbers ” for the
FlashSystem 9500?

6 M Input / Output operations per second (IOPS) and


lOOGB/ s bandwidth
8 M Input / Output operations per second (IOPS) and
lOOGB/ s bandwidth
6 M Input / Output operations per second (IOPS) and x
150GB/ s bandwidth
4M Input / Output operations per second (IOPS) and
200GB/ s bandwidth

Question 19

Correct

Points out of 1.00

In late February of 2024 an article in Forbes stated “IBM’s


storage solutions remain among the most technologically
advanced on the market, making them ideal to protect critical
enterprise data.” What new feature should sellers tell clients
about, that caused the publication to make that comment ?

IBM Storage Virtualize

IBM Storage Defender


IBM Data Reduction Pools

Ransomware Threat Detection

©
Question 20

Correct

Points out of 1.00

Back Next

Assuming a client achieves 3 :1data reduction with FlashCore


Module 4s (FCM 4s), what is the maximum raw effective
capacity that is possible in the FlashSystem 9500 control
enclosure?

3.0PB

4.5 PB
*
3.5 PB

4.0PB

Question 21

Correct

Points out of 1.00

A client is interested in using lOOGbE host ports in a


FlashSystem 9500. What is the maximum number of lOOGbE
ports that can be configured in a 9500?

12
*
16

O
Question 22

Incorrect

Points out of 1.00

Back Next

A client has just acquired a new company and they are looking
to consolidate many new workloads. They currently have a
FlashSystem 5200 and are asking how much of a change will
they see with respect to performance, capacity, ports and
more if they acquire a FlashSystem 9500. What is an easy
number to use to represent the change?

4x

3x

3.5 x
2.5 x X

Question 23

Correct

Points out of 1.00

What is the maximum number of Fibre Channel (FC) host bus


adapter (HBA) cards that the FlashSystem 9500 supports ?

10
16

12 V
8

e
Question 24

Correct

Points out of 1.00

Back Next

The FlashSystem 9500 and FlashSystem 9500 R support


numerous media types between the control enclosure and
expansion enclosures. Which of the following media types is
NOT supported?

Non - Volatile Memory express (NVMe) solid - state drives


(SSDs)

FlashCore Modules
SAS SSDs

Serial- attach SCSI (SAS) hard disk drives (FIDDs)

Question 25

Correct

Points out of 1.00

What is the number of central processing unit (CPU) cores in a


single FlashSystem 9500?

Two 24- core CPUs per controller, for a total of 96 -


cores per system
Two 28 - core CPUs per controller, for a total of 112 - cores
per system
Two 20 - core CPUs per controller, for a total of 80 - cores
per system
Two 16 - core CPUs per controller, for a total of 64 - cores
per system