Actuated Ball Valve Selection Guide, ISO 5211-Compliant Actuator Mounting Bracket Kits 1

www.swagelok.com

Actuated Ball Valve


Sele ction Guide
ISO 5211- Complia nt Actuator
Mounting Bracket K its

BALL VALVE
SELECTION

40 G, 40, 6 0, 83, H83, SK, a nd FK B Se r ie s Valve s ACTUATED

AFS Ball Valve s


■ Calculate valve operating torque

■ Choose actuators and related components

■ Select mounting bracket kits


2 Ball Valves and Quarter-Turn Plug Valves

Contents 40G Series Valves


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Valve Operating Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
40G Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
40 Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
60 Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
83 and H83 Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AFS Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SK Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
FKB Series Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Swagelok 43G series valve
with ISO 5211-compliant
Mounting Bracket Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 actuator.

Actuated Ball Valve Assemblies . . . . . . . . . . . . . . . . . . . . . 12


Operating Torque
Introduction Operating torque for a Swagelok 40G series ball valve is
influenced by:
BALL VALVE

This guide enables the user to:


SELECTION
ACTUATED

■ determine the operating torque for Swagelok® 40G, 40, 60, ■ packing material
83, H83, SK, and FKB series valves and AFS ball valves in a ■ system pressure
variety of operating conditions ■ system temperature
■ select and size actuators, based on valve operating torque
■ system media.
■ choose Swagelok ISO 5211 dimensionally compliant
The tables and calculations on page 3 can be used for 2-
mounting bracket kits, based on calculated operating and 3-way stainless steel 40G series valves.
torque values and actuator manufacturers’ literature.

Valve Operating Torque


Start (break) torque is the torque required to begin actuation Seat or Packing Material
of a valve. The actuator start torque must be greater than the In some ball valve designs, friction between ball and seat or
valve start torque. packing affects operating torque, which varies with material
End (run) torque is the torque required to complete the and lubricant.
actuation. The actuator end torque must be greater than the
valve end torque. System Pressure
Higher pressures cause greater contact forces and friction,
Factors that Affect Operating Torque resulting in higher operating torque.
Frequency of Use
System Temperature
Operating torque typically increases as the time interval
The values given in the tables that follow were generated at
between cycles increases.
room temperature. Lower or higher temperatures, depending
For applications in which valves are cycled less frequently on the valve design, can cause increased operating torque.
than noted in the Calculating Operating Torque
instructions, contact your authorized Swagelok sales and System Media
service representative. The values given in the tables that follow were generated with
clean, dry nitrogen gas. Different system fluids have varying
Cycle Wear
viscosities, bringing about different levels of friction and
Contacting surfaces—valve ball, seat, and body, for affecting operating torque. Some lightweight oils may reduce
example—gradually wear as valves are actuated repeatedly, operating torque. Dirty, abrasive, or highly viscous fluids may
resulting in increased friction and operating torque. Actuation increase operating torque.
speed may influence the rate of valve wear as well.
For applications in which valves are actuated rapidly or
repeatedly—more often than once per hour—contact your
authorized Swagelok representative.
Actuated Ball Valve Selection Guide, ISO 5211-Compliant Actuator Mounting Bracket Kits 3

40G Series Valves


Calculating Operating Torque Example: A 43G valve with modified Ordering Information
1. Select the base start and base end PTFE packing is operated with nitrogen 1. Select the desired 40G series valve
torque at system pressure from at 2500 psig and 70°F (20°C). and packing material. Using the
Table 1. 1. According to Table 1, the base start Calculating Operating Torque
2. Select the temperature factor from torque is 37 in.·lb and the base end instructions at left, calculate the
Table 2. torque is 11 in.·lb. valve start and end torque.
3. Select the media factor from Table 3. 2. According to Table 2, the 2. Choose an actuator based on the
temperature factor is 1.0. valve start and end torque. See the
4. Calculate the start and end
3. According to Table 3, the media actuator manufacturer’s literature
operating torque:
factor is 1.0. to specify ISO 5211 mounting
Base torque (Table 1)
dimensions, including flange and
× temperature factor (Table 2) 4. Start torque = 37 in.·lb × 1.0 × 1.0
coupling sizes.
× media factor (Table 3). = 37 in.·lb
3. Select a mounting bracket kit
End torque = 11 in.·lb × 1.0 × 1.0
ordering number based on valve
= 11 in.·lb
series, flange size, and coupling
size.
Table 1—Base Start and End Torque
Use linear interpolation to obtain torque values for system pressures not listed.

BALL VALVE
SELECTION

ACTUATED
System Pressure, psig (bar, MPa)
0 to 1000 (68.9, 6.89) 1500 (103, 10.3) 2500 (172, 17.2) 3000 (206, 20.6)
Base Torque, in.·lb (N·m, cm·kg)
Valve
Series Start End Start End Start End Start End
41G/42G 13 (1.5, 15) 7 (0.8, 8.1) 15 (1.7, 18) 7 (0.8, 8.1) 15 (1.7, 18) 8 (0.9, 9.3)
41GE/42GE 10 (1.2, 12) 7 (0.8, 8.1) 11 (1.3, 13) 7 (0.8, 8.1) 12 (1.4, 14) 8 (0.9, 9.3) — —
41G-1466/42G-1466 13 (1.5, 15) 7 (0.8, 8.1) — — — —
43G 32 (3.7, 37) 9 (1.1, 11) 33 (3.8, 39) 10 (1.2, 12) 37 (4.2, 43) 11 (1.3, 13) 40 (4.6, 47) 11 (1.3, 13)
43GE 23 (2.6, 27) 10 (1.2, 12) 25 (2.9, 29) 11 (1.3, 13) 27 (3.1, 32) 12 (1.4, 14) 30 (3.4, 35) 13 (1.5, 15)
43G-1466 28 (3.2, 33) 16 (1.9, 19) — — — — — —

Table 2—Temperature Factors Mounting Bracket Kit Ordering Numbers


Use linear interpolation to obtain factors for
Valve ISO 5211 Coupling Cap Screw Bracket Kit
system temperatures not listed. Series Flange Size Size Type Ordering Number
9 mm ISO Metric SS-MB-41G-F03-9ISO-M
Temperature, ˚F (˚C) 9 mm ISO Fractional SS-MB-41G-F03-9ISO-F
F03
Valve –65 50 to 300 9 mm DIN Metric SS-MB-41G-F03-9DIN-M
Series (–53) (10 to 148) 9 mm DIN Fractional SS-MB-41G-F03-9DIN-F
41G/42G 1.0 1.0 9 mm ISO Metric SS-MB-41G-F04-9ISO-M
41GE/42GE 1.5 1.0 41G/ 9 mm ISO Fractional SS-MB-41G-F04-9ISO-F
41G-1466/42G-1466 1.0 1.0 42G 9 mm DIN Metric SS-MB-41G-F04-9DIN-M
9 mm DIN Fractional SS-MB-41G-F04-9DIN-F
43G 1.0 1.0 F04
11 mm ISO Metric SS-MB-41G-F04-11ISO-M
43GE 1.5 1.0
11 mm ISO Fractional SS-MB-41G-F04-11ISO-F
43G-1466 1.0 1.0
11 mm DIN Metric SS-MB-41G-F04-11DIN-M
11 mm DIN Fractional SS-MB-41G-F04-11DIN-F
Table 3—Media Factors 9 mm ISO Metric SS-MB-43G-F03-9ISO-M
9 mm ISO Fractional SS-MB-43G-F03-9ISO-F
F03
Medium- Clean Nitrogen 9 mm DIN Metric SS-MB-43G-F03-9DIN-M
Weight Oil Water Gas 9 mm DIN Fractional SS-MB-43G-F03-9DIN-F
9 mm ISO Metric SS-MB-43G-F04-9ISO-M
0.85 1.0 1.0
9 mm ISO Fractional SS-MB-43G-F04-9ISO-F
9 mm DIN Metric SS-MB-43G-F04-9DIN-M
9 mm DIN Fractional SS-MB-43G-F04-9DIN-F
40G Series Valve Designators F04
11 mm ISO Metric SS-MB-43G-F04-11ISO-M
None—standard, modified PTFE packing 11 mm ISO Fractional SS-MB-43G-F04-11ISO-F
43G
E—UHMWPE packing 11 mm DIN Metric SS-MB-43G-F04-11DIN-M
-1466—modified PTFE packing, assembled 11 mm DIN Fractional SS-MB-43G-F04-11DIN-F
without lubricant and cleaned and packaged 11 mm ISO Metric SS-MB-43G-F05-11ISO-M
in accordance with Swagelok Special Cleaning 11 mm ISO Fractional SS-MB-43G-F05-11ISO-F
and Packaging (SC-11) (MS-06-63). 11 mm DIN Metric SS-MB-43G-F05-11DIN-M
11 mm DIN Fractional SS-MB-43G-F05-11DIN-F
F05
14 mm ISO Metric SS-MB-43G-F05-14ISO-M
See Mounting Instructions, ISO 5211 14 mm ISO Fractional SS-MB-43G-F05-14ISO-F
Dimensionally Compliant Bracket, Coupling, 14 mm DIN Metric SS-MB-43G-F05-14DIN-M
and Actuator, MS‑INS‑4080‑NAMUR. 14 mm DIN Fractional SS-MB-43G-F05-14DIN-F
4 Ball Valves and Quarter-Turn Plug Valves

40 Series Valves
Operating Torque Calculating Operating Torque 1. According to Table 4, the base start
Operating torque for a Swagelok 40 If the valve will be cycled at least once per torque is 33 in.·lb and the base end
series ball valve is influenced by: 3 days, but not more than once per hour: torque is 10 in.·lb.
■ cycle frequency 1. Select the base start and base end 2. According to Table 5, the
torque at system pressure from temperature factor is 1.0.
■ packing material
Table 4. 3. According to Table 6, the media
■ system pressure
2. Select the temperature factor from factor is 1.0.
■ system temperature
Table 5. 4. Start torque = 33 in.·lb × 1.0 × 1.0
■ system media. = 33 in.·lb
3. Select the media factor from Table 6.
The tables and calculations on this End torque = 10 in.·lb × 1.0 × 1.0
4. Calculate the start and end operating
page can be used for 2- and 3-way 40 = 10 in.·lb.
torque:
series valves in stainless steel, brass, If the valve will be cycled less frequently
Base torque (Table 4)
and alloy 400 materials. than once per 3 days or more frequently
× temperature factor (Table 5)
× media factor (Table 6). than once per hour, contact your
Example: A 43 series valve with PTFE authorized Swagelok representative.
packing is operated with nitrogen at
1500 psig and 70°F (20°C) and cycled
every 3 days.
BALL VALVE
SELECTION
ACTUATED

Table 4—Base Start and End Torque Table 5—Temperature Factors


Use linear interpolation to obtain torque values for system pressures not listed. Use linear interpolation to obtain factors
for temperatures from –65 to 50°F
System Pressure, psig (bar, MPa) (–53 to 10°C).
0 to 1000 (68.9, 6.89) 1500 (103, 10.3)
Valve Base Torque, in.·lb (N·m, cm·kg) Temperature, °F (°C)
Series Start End Start End Valve (–65) 50 to 150
41/42 13 (1.5, 15) 7 (0.8, 8.1) 15 (1.7, 18) 7 (0.8, 8.1) Series (–53) (10 to 65)
41T/42T 13 (1.5, 15) 7 (0.8, 8.1) 15 (1.7, 18) 7 (0.8, 8.1) 41/42 1.0 1.0
41E/42E 10 (1.2, 12) 7 (0.8, 8.1) 11 (1.3, 13) 7 (0.8, 8.1) 41T/42T 1.0 1.0
41-1466/42-1466 13 (1.5, 15) 7 (0.8, 8.1) — — 41E/42E 1.5 1.0
43 32 (3.7, 37) 9 (1.1, 11) 33 (3.8, 39) 10 (1.2, 12) 41-1466/42-1466 1.0 1.0
43T 36 (4.1, 42) 15 (1.7, 18) 38 (4.3, 44) 16 (1.9, 19) 43 1.0 1.0
43E 23 (2.6, 27) 10 (1.2, 12) 25 (2.9, 29) 11 (1.3, 13) 43T 1.0 1.0
43-1466 28 (3.2, 33) 16 (1.9, 19) — — 43E 1.5 1.0
44 37 (4.2, 43) 20 (2.3, 24) 40 (4.6, 47) 22 (2.5, 26) 43-1466 1.0 1.0
44T 48 (5.5, 56) 22 (2.5, 26) 52 (5.9, 60) 23 (2.6, 27) 44 1.0 1.0
44E 70 (8.0, 81) 33 (3.8, 39) 75 (8.5, 87) 35 (4.0, 41) 44T 1.35 1.0
44-1466 60 (6.8, 70) 40 (4.6, 47) — — 44E 1.5 1.0
45 80 (9.1, 93) 30 (3.4, 35) 85 (9.7, 98) 32 (3.7, 37) 44-1466 1.0 1.0
45T 80 (9.1, 93) 35 (4.0, 41) 85 (9.7, 98) 37 (4.2, 43) 45 1.0 1.0
45E 130 (14.7, 150) 46 (5.2, 53) 135 (15.3, 156) 50 (5.7, 58) 45T 1.35 1.0
45-1466 135 (15.3, 156) 95 (10.8, 110) — — 45E 1.5 1.0
45-1466 1.0 1.0
System Pressure, psig (bar, MPa)
2500 (172, 17.2) 3000 (206, 20.6) Table 6—Media Factors
Valve Base Torque, in.·lb (N·m, cm·kg)
Series Start End Start End Medium- Clean Nitrogen
Weight Oil Water Gas
41/42 15 (1.7, 18) 8 (0.9, 9.3)
41T/42T 15 (1.7, 18) 8 (0.9, 9.3) 0.85 1.0 1.0
— —
41E/42E 12 (1.4, 14) 8 (0.9, 9.3)
41-1466/42-1466 — —
43 37 (4.2, 43) 11 (1.3, 13) 40 (4.6, 47) 11 (1.3, 13) 40 Series Valve Designators
43T 42 (4.8, 49) 18 (2.1, 21) 45 (5.1, 52) 20 (2.3, 24) None—standard, PTFE packing
43E 27 (3.1, 32) 12 (1.4, 14) 30 (3.4, 35) 13 (1.5, 15)
43-1466 — — — — T—low-temperature, PFA packing
E—low-temperature, UHMWPE
44 44 (5.0, 51) 25 (2.9, 29)
packing
44T 57 (6.5, 66) 26 (3.0, 30)
— — -1466—modified PTFE packing,
44E 83 (9.4, 96) 40 (4.6, 47)
44-1466 — — assembled without lubricant and cleaned
and packaged in accordance with
45 95 (10.8, 110) 35 (4.0, 41) Swagelok Special Cleaning and Packaging
45T 95 (10.8, 110) 42 (4.8,49) (SC-11) (MS-06-63).
— —
45E 150 (17.0, 173) 55 (6.3, 64)
45-1466 — —
Actuated Ball Valve Selection Guide, ISO 5211-Compliant Actuator Mounting Bracket Kits 5

40 Series Valves
Ordering Information
1. Select the desired 40 series valve and packing material.
Using the Calculating Operating Torque instructions at
left, calculate the valve start and end torque.
2. Choose an actuator based on the valve start and end
torque. See the actuator manufacturer’s literature to specify
ISO 5211 mounting dimensions, including flange and
coupling sizes.
3. Select a Swagelok 40 series bracket kit ordering number.
Bracket kits can be used with stainless steel, brass, and
alloy 400 valves with K-style, double-flat stems.
K-style stems are standard for all many 44 and 45 series
valves, but are optional for 41, 42, and 43 series valves.
For more information, contact your authorized Swagelok
representative.
To order a valve with a K-style, double-flat stem and without
a handle, if they are not standard, add -K-NH to the valve
ordering number.

BALL VALVE
SELECTION

ACTUATED
Example: SS-41S1-K-NH
See Mounting Instructions, ISO 5211 Dimensionally Compliant
Swagelok 45 series valve
Bracket, Coupling, and Actuator, MS‑INS‑4080‑NAMUR. with El-O-Matic® actuator
and Westlock® limit switch.

Mounting Bracket Kit Ordering Numbers

ISO ISO
5211 5211
Valve Flange Coupling Cap Screw Bracket Kit Valve Flange Coupling Cap Screw Bracket Kit
Series Size Size Type Ordering Number Series Size Size Type Ordering Number
9 mm ISO Metric SS-MB-41-F03-9ISO-M 9 mm ISO Metric SS-MB-44-F03-9ISO-M
9 mm ISO Fractional SS-MB-41-F03-9ISO-F 9 mm ISO Fractional SS-MB-44-F03-9ISO-F
F03 F03
9 mm DIN Metric SS-MB-41-F03-9DIN-M 9 mm DIN Metric SS-MB-44-F03-9DIN-M
9 mm DIN Fractional SS-MB-41-F03-9DIN-F 9 mm DIN Fractional SS-MB-44-F03-9DIN-F
9 mm ISO Metric SS-MB-41-F04-9ISO-M 11 mm ISO Metric SS-MB-44-F04-11ISO-M
9 mm ISO Fractional SS-MB-41-F04-9ISO-F 11 mm ISO Fractional SS-MB-44-F04-11ISO-F
41/42 F04
9 mm DIN Metric SS-MB-41-F04-9DIN-M 11 mm DIN Metric SS-MB-44-F04-11DIN-M
9 mm DIN Fractional SS-MB-41-F04-9DIN-F 11 mm DIN Fractional SS-MB-44-F04-11DIN-F
F04 44
11 mm ISO Metric SS-MB-41-F04-11ISO-M 11 mm ISO Metric SS-MB-44-F05-11ISO-M
11 mm ISO Fractional SS-MB-41-F04-11ISO-F 11 mm ISO Fractional SS-MB-44-F05-11ISO-F
11 mm DIN Metric SS-MB-41-F04-11DIN-M 11 mm DIN Metric SS-MB-44-F05-11DIN-M
11 mm DIN Fractional SS-MB-41-F04-11DIN-F 11 mm DIN Fractional SS-MB-44-F05-11DIN-F
F05
9 mm ISO Metric SS-MB-43-F03-9ISO-M 14 mm ISO Metric SS-MB-44-F05-14ISO-M
9 mm ISO Fractional SS-MB-43-F03-9ISO-F 14 mm ISO Fractional SS-MB-44-F05-14ISO-F
F03
9 mm DIN Metric SS-MB-43-F03-9DIN-M 14 mm DIN Metric SS-MB-44-F05-14DIN-M
9 mm DIN Fractional SS-MB-43-F03-9DIN-F 14 mm DIN Fractional SS-MB-44-F05-14DIN-F
9 mm ISO Metric SS-MB-43-F04-9ISO-M 11 mm ISO Metric SS-MB-45-F05-11ISO-M
9 mm ISO Fractional SS-MB-43-F04-9ISO-F 11 mm ISO Fractional SS-MB-45-F05-11ISO-F
9 mm DIN Metric SS-MB-43-F04-9DIN-M 11 mm DIN Metric SS-MB-45-F05-11DIN-M
9 mm DIN Fractional SS-MB-43-F04-9DIN-F 11 mm DIN Fractional SS-MB-45-F05-11DIN-F
F04
11 mm ISO Metric SS-MB-43-F04-11ISO-M 14 mm ISO Metric SS-MB-45-F05-14ISO-M
11 mm ISO Fractional SS-MB-43-F04-11ISO-F 14 mm ISO Fractional SS-MB-45-F05-14ISO-F
43 F05
11 mm DIN Metric SS-MB-43-F04-11DIN-M 14 mm DIN Metric SS-MB-45-F05-14DIN-M
11 mm DIN Fractional SS-MB-43-F04-11DIN-F 14 mm DIN Fractional SS-MB-45-F05-14DIN-F
45
11 mm ISO Metric SS-MB-43-F05-11ISO-M 17 mm ISO Metric SS-MB-45-F05-17ISO-M
11 mm ISO Fractional SS-MB-43-F05-11ISO-F 17 mm ISO Fractional SS-MB-45-F05-17ISO-F
11 mm DIN Metric SS-MB-43-F05-11DIN-M 17 mm DIN Metric SS-MB-45-F05-17DIN-M
11 mm DIN Fractional SS-MB-43-F05-11DIN-F 17 mm DIN Fractional SS-MB-45-F05-17DIN-F
F05
14 mm ISO Metric SS-MB-43-F05-14ISO-M 17 mm ISO Metric SS-MB-45-F07-17ISO-M
14 mm ISO Fractional SS-MB-43-F05-14ISO-F 17 mm ISO Fractional SS-MB-45-F07-17ISO-F
F07
14 mm DIN Metric SS-MB-43-F05-14DIN-M 17 mm DIN Metric SS-MB-45-F07-17DIN-M
14 mm DIN Fractional SS-MB-43-F05-14DIN-F 17 mm DIN Fractional SS-MB-45-F07-17DIN-F
6 Ball Valves and Quarter-Turn Plug Valves

60 Series Valves
Operating Torque Calculating Operating Torque 1. According to Table 7, the base start
Operating torque for a Swagelok 60 If the valve will be cycled at least once per torque is 62 in.·lb and the base end
series valve is influenced by: day, but not more than once per hour: torque is 37 in.·lb.
■ cycle frequency 1. Select the base start and base end 2. According to Table 8, the
torque at system pressure from temperature factor is 1.0.
■ seat material
Table 7. 3. According to Table 9, the media
■ system pressure
2. Select the temperature factor from factor is 1.0.
■ system temperature
Table 8. 4. Start torque = 62 in.·lb × 1.0 × 1.0
■ system media. = 62 in.·lb
3. Select the media factor from Table 9.
The tables and calculations on this End torque = 37 in.·lb × 1.0 × 1.0
4. Calculate the start and end operating
page can be used for 2- and 3-way 60 = 37 in.·lb.
torque:
series valves in stainless steel, carbon If the valve will be cycled less frequently
Base torque (Table 7)
steel, and brass materials. than once per day or more frequently
× temperature factor (Table 8)
× media factor (Table 9). than once per hour, contact your
Example: A 63 series valve with authorized Swagelok representative.
reinforced PTFE seat is operated with
nitrogen at 1500 psig and 70°F (20°C)
and cycled once per day.
BALL VALVE
SELECTION
ACTUATED

Table 7—Base Start and End Torque Table 8—Temperature Factors


Use linear interpolation to obtain torque values for system pressures not listed. Use linear interpolation to obtain factors
for temperatures from 100 to 450°F
System Pressure, psig (bar, MPa) (37 to 232°C).
0 1000 (68.9, 6.89) 1500 (103, 10.3)
Temperature, °F (°C)
Base Torque, in.·lb (N·m, cm·kg)
Valve Valve –20 to 100 450
Series Start End Start End Start End Series (–28 to 37) (232)
62T 18 (2.1, 21) 16 (1.9, 19) 22 (2.5, 26) 20 (2.3, 24) 25 (2.9, 29) 22 (2.5, 26) 62T 1.0 1.9
62P 25 (2.9, 29) 16 (1.9, 19) 25 (2.9, 29) 16 (1.9, 19) 30 (3.4, 35) 20 (2.3, 24) 62P 1.0 1.0
63T 52 (5.9, 60) 28 (3.2, 33) 58 (6.6, 67) 35 (4.0, 41) 62 (7.1, 72) 37 (4.2, 43) 63T 1.0 3.0
63P 50 (5.7, 58) 40 (4.6, 47) 50 (5.7, 58) 40 (4.6, 47) 65 (7.4, 75) 50 (5.7, 58) 63P 1.0 1.0
65T 125 (14.2, 144) 60 (6.8, 70) 160 (18.1, 185) 100 (11.3, 116) 180 (20.4, 208) 120 (13.6, 139) 65T 1.0 2.3
65P 90 (10.2, 104) 75 (8.5, 87) 90 (10.2, 104) 75 (8.5, 87) 150 (17.0, 173) 125 (14.2, 144) 65P 1.0 1.2
67T 250 (28.3, 288) 120 (13.6, 139) 290 (32.8, 335) 140 (15.9, 162) 310 (35.1, 358) 145 (16.4, 168) 67T 1.0 2.0
67P 190 (21.5, 219) 160 (18.1, 185) 190 (21.5, 219) 160 (18.1, 185) 275 (31.1, 317) 230 (26.0, 265) 67P 1.0 1.0
68T 290 (32.8, 335) 135 (15.3, 156) 370 (41.9, 427) 200 (22.6, 231) 500 (56.5, 576) 235 (26.6, 271) 68T 1.0 2.8
68P 280 (31.7, 323) 230 (26.0, 265) 280 (31.7, 323) 230 (26.0, 265) 360 (40.7, 415) 295 (33.4, 340) 68P 1.0 1.0

System Pressure, psig (bar, MPa)


2200 (151, 15.1) 2500 (172, 17.2) 3000 (206, 20.6) Table 9—Media Factors
Base Torque, in.·lb (N·m, cm·kg)
Valve Medium-
Series Start End Start End Start End Seat Weight Clean Nitrogen
62T 26 (3.0, 30) 23 (2.6, 27) — — — — Material Oil Water Gas
62P 37 (4.2, 43) 23 (2.6, 27) 40 (4.6, 47) 25 (2.9, 29) 45 (5.1, 52) 30 (3.4, 35) PTFE 0.9 1.0 1.0
63T 67 (7.6, 78) 42 (4.8, 49) — — PEEK 1.0 1.0 1.0
— —
63P 100 (11.3, 116) 75 (8.5, 85) 110 (12.5, 127) 85 (9.7, 98)
65T 205 (23.2, 237) 150 (17.0, 173) — —
— —
65P 230 (26.0, 265) 190 (21.5, 219) 260 (29.4, 300) 215 (24.3, 248)
67T 335 (37.9, 386) 160 (18.1, 185)
— — — —
60 Series Valve Designators
67P 405 (45.8, 467) 340 (38.5, 392) T—reinforced PTFE seat and packing
68T 500 (56.5, 576) 280 (31.7, 323)
— — — — P—PEEK seat and packing
68P 485 (54.9, 559) 400 (45.2, 461)
Actuated Ball Valve Selection Guide, ISO 5211-Compliant Actuator Mounting Bracket Kits 7

60 Series Valves
Ordering Information
1. Select the desired 4-bolt 60 series valve and seat material.
Using the Calculating Operating Torque instructions at
left, calculate the valve start and end operating torque.
For 60 series valves with encased 8-bolt construction,
contact your authorized Swagelok representative.
2. Choose an actuator based on the valve start and end
torque. See the actuator manufacturer’s literature to specify
ISO 5211 mounting dimensions, including flange and
coupling sizes.
3. Select a Swagelok 60 series bracket kit ordering number.
Bracket kits can be used with stainless steel, carbon steel,
and alloy 400 valves.
To order bracket kits for brass valves, insert -B into the
bracket kit ordering number.
Example: SS-MB-62-B-F03-9ISO-M
Swagelok 63 series valve
See Mounting Instructions, ISO 5211 Dimensionally Compliant with ISO 5211-compliant
Bracket, Coupling, and Actuator to 4-Bolt 60 Series Valves, actuator, ASCO® solenoid, and

BALL VALVE
SELECTION

ACTUATED
Pepperl+Fuchs proximity sensor.
MS-INS-4B60NM.

Mounting Bracket Kit Ordering Numbers

ISO ISO
5211 5211
Valve Flange Coupling Cap Screw Bracket Kit Valve Flange Coupling Cap Screw Bracket Kit
Series Size Size Type Ordering Number Series Size Size Type Ordering Number
9 mm ISO Metric SS-MB-62-F03-9ISO-M 14 mm ISO Metric SS-MB-65-F05-14ISO-M
9 mm ISO Fractional SS-MB-62-F03-9ISO-F 14 mm ISO Fractional SS-MB-65-F05-14ISO-F
9 mm DIN Metric SS-MB-62-F03-9DIN-M 14 mm DIN Metric SS-MB-65-F05-14DIN-M
9 mm DIN Fractional SS-MB-62-F03-9DIN-F 14 mm DIN Fractional SS-MB-65-F05-14DIN-F
F05
11 mm ISO Metric SS-MB-62-F03-11ISO-M 17 mm ISO Metric SS-MB-65-F05-17ISO-M
11 mm ISO Fractional SS-MB-62-F03-11ISO-F 17 mm ISO Fractional SS-MB-65-F05-17ISO-F
F03
11 mm DIN Metric SS-MB-62-F03-11DIN-M 17 mm DIN Metric SS-MB-65-F05-17DIN-M
11 mm DIN Fractional SS-MB-62-F03-11DIN-F 17 mm DIN Fractional SS-MB-65-F05-17DIN-F
65
14 mm ISO Metric SS-MB-62-F03-14ISO-M 14 mm ISO Metric SS-MB-65-F07-14ISO-M
14 mm ISO Fractional SS-MB-62-F03-14ISO-F 14 mm ISO Fractional SS-MB-65-F07-14ISO-F
14 mm DIN Metric SS-MB-62-F03-14DIN-M 14 mm DIN Metric SS-MB-65-F07-14DIN-M
14 mm DIN Fractional SS-MB-62-F03-14DIN-F 14 mm DIN Fractional SS-MB-65-F07-14DIN-F
62 F07
9 mm ISO Metric SS-MB-62-F04-9ISO-M 17 mm ISO Metric SS-MB-65-F07-17ISO-M
9 mm ISO Fractional SS-MB-62-F04-9ISO-F 17 mm ISO Fractional SS-MB-65-F07-17ISO-F
9 mm DIN Metric SS-MB-62-F04-9DIN-M 17 mm DIN Metric SS-MB-65-F07-17DIN-M
9 mm DIN Fractional SS-MB-62-F04-9DIN-F 17 mm DIN Fractional SS-MB-65-F07-17DIN-F
11 mm ISO Metric SS-MB-62-F04-11ISO-M 14 mm ISO Metric SS-MB-67-F07-14ISO-M
11 mm ISO Fractional SS-MB-62-F04-11ISO-F 14 mm ISO Fractional SS-MB-67-F07-14ISO-F
F04
11 mm DIN Metric SS-MB-62-F04-11DIN-M 14 mm DIN Metric SS-MB-67-F07-14DIN-M
11 mm DIN Fractional SS-MB-62-F04-11DIN-F 14 mm DIN Fractional SS-MB-67-F07-14DIN-F
67 F07
14 mm ISO Metric SS-MB-62-F04-14ISO-M 17 mm ISO Metric SS-MB-67-F07-17ISO-M
14 mm ISO Fractional SS-MB-62-F04-14ISO-F 17 mm ISO Fractional SS-MB-67-F07-17ISO-F
14 mm DIN Metric SS-MB-62-F04-14DIN-M 17 mm DIN Metric SS-MB-67-F07-17DIN-M
14 mm DIN Fractional SS-MB-62-F04-14DIN-F 17 mm DIN Fractional SS-MB-67-F07-17DIN-F
11 mm ISO Metric SS-MB-63-F05-11ISO-M 14 mm ISO Metric SS-MB-68-F07-14ISO-M
11 mm ISO Fractional SS-MB-63-F05-11ISO-F 14 mm ISO Fractional SS-MB-68-F07-14ISO-F
11 mm DIN Metric SS-MB-63-F05-11DIN-M 14 mm DIN Metric SS-MB-68-F07-14DIN-M
11 mm DIN Fractional SS-MB-63-F05-11DIN-F 14 mm DIN Fractional SS-MB-68-F07-14DIN-F
68 F07
14 mm ISO Metric SS-MB-63-F05-14ISO-M 17 mm ISO Metric SS-MB-68-F07-17ISO-M
14 mm ISO Fractional SS-MB-63-F05-14ISO-F 17 mm ISO Fractional SS-MB-68-F07-17ISO-F
63 F05
14 mm DIN Metric SS-MB-63-F05-14DIN-M 17 mm DIN Metric SS-MB-68-F07-17DIN-M
14 mm DIN Fractional SS-MB-63-F05-14DIN-F 17 mm DIN Fractional SS-MB-68-F07-17DIN-F
17 mm ISO Metric SS-MB-63-F05-17ISO-M
17 mm ISO Fractional SS-MB-63-F05-17ISO-F
17 mm DIN Metric SS-MB-63-F05-17DIN-M
17 mm DIN Fractional SS-MB-63-F05-17DIN-F
8 Ball Valves and Quarter-Turn Plug Valves

83 and H83 Series Valves


Operating Torque Calculating Operating Torque 1. According to Table 10, the base start
Operating torque for a Swagelok 83 or If the valve will be cycled no more than torque is 25 in.·lb and the base end
H83 series valve is influenced by: once per hour: torque is 15 in.·lb.
■ system pressure 1. Select the base start and base end 2. According to Table 11, the media
torque at system pressure from factor is 0.9.
■ cycle frequency
Table 10. 3. Start torque = 25 in.·lb × 0.9
■ system media.
2. Select the media factor from = 22.5 in.·lb
The tables and calculations on this End torque = 15 in.·lb × 0.9
Table 11.
page can be used for 83 and H83 = 13.5 in.·lb.
series valves of stainless steel and alloy 3. Calculate the start and end operating
400 with any seat material. torque: If the valve will be cycled more
Base torque (Table 10) frequently than once per hour,
× media factor (Table 11). contact your authorized Swagelok
Example: An 83 series 3-way valve is representative.
operated with medium-weight oil at
1500 psig and cycled once per day.

Table 10—Base Start and End Torque


Use linear interpolation to obtain torque values for system pressures not listed.
BALL VALVE
SELECTION
ACTUATED

System Pressure, psig (bar, MPa)


0 1500 (103, 10.3) 3000 (206, 20.6) 6000 (413, 41.3) 10 000 (689, 68.9)
Base Torque, in.·lb (N·m, cm·kg)
Valve
Series Start End Start End Start End Start End Start End
83 2-way 15 (1.7, 18) 15 (1.7, 18) 15 (1.7, 18) 15 (1.7, 18) 17 (2.0, 20) 17 (2.0, 20) 20 (2.3, 24) 20 (2.3, 24) — —
83 3-way 25 (2.9, 29) 15 (1.7, 18) 25 (2.9, 29) 15 (1.7, 18) 27 (3.1, 32) 17 (2.0, 20) 30 (3.4, 35) 20 (2.3, 24) — —
All H83 25 (2.9, 29) 15 (1.7, 18) 25 (2.9, 29) 15 (1.7, 18) 27 (3.1, 32) 17 (2.0, 20) 30 (3.4, 35) 20 (2.3, 24) 35 (4.0, 41) 20 (2.3, 24)

Ordering Information Table 11—Media Factors

Medium- Clean Nitrogen


Weight Oil Water Gas
0.9 1.0 1.0

Mounting Bracket Kit Ordering Numbers


ISO 5211
Flange Coupling Cap Screw Bracket Kit
Size Size Type Ordering Number
9 mm ISO Metric SS-MB-83-F03-9ISO-M
9 mm ISO Fractional SS-MB-83-F03-9ISO-F
F03
9 mm DIN Metric SS-MB-83-F03-9DIN-M
9 mm DIN Fractional SS-MB-83-F03-9DIN-F
Swagelok 83 series valve 9 mm ISO Metric SS-MB-83-F04-9ISO-M
with ISO 5211-compliant 9 mm ISO Fractional SS-MB-83-F04-9ISO-F
actuator. 9 mm DIN Metric SS-MB-83-F04-9DIN-M
9 mm DIN Fractional SS-MB-83-F04-9DIN-F
F04
1. Select the desired 83 or H83 series valve. Using the 11 mm ISO Metric SS-MB-83-F04-11ISO-M
Calculating Operating Torque instructions above, 11 mm ISO Fractional SS-MB-83-F04-11ISO-F
11 mm DIN Metric SS-MB-83-F04-11DIN-M
calculate the valve start and end operating torque.
11 mm DIN Fractional SS-MB-83-F04-11DIN-F
2. Choose an actuator based on the valve start and end 11 mm ISO Metric SS-MB-83-F05-11ISO-M
torque. See the actuator manufacturer’s literature to specify 11 mm ISO Fractional SS-MB-83-F05-11ISO-F
ISO 5211 mounting dimensions, including flange and 11 mm DIN Metric SS-MB-83-F05-11DIN-M
coupling sizes. 11 mm DIN Fractional SS-MB-83-F05-11DIN-F
F05
3. Select a Swagelok 83 series bracket kit ordering number. 14 mm ISO Metric SS-MB-83-F05-14ISO-M
14 mm ISO Fractional SS-MB-83-F05-14ISO-F
Bracket kits can be used with stainless steel and alloy 400 14 mm DIN Metric SS-MB-83-F05-14DIN-M
valves. 14 mm DIN Fractional SS-MB-83-F05-14DIN-F
See Mounting Instructions, ISO 5211 Dimensionally Compliant
Bracket, Coupling, and Actuator, MS‑INS‑4080‑NAMUR.
Actuated Ball Valve Selection Guide, ISO 5211-Compliant Actuator Mounting Bracket Kits 9

AFS Ball Valves


Operating Torque Calculating Operating Torque 1. According to Table 12, the base start
Operating torque for a Swagelok AFS If the valve will be cycled at least once per torque is 61 in.·lb and the base end
ball valve is influenced by: day, but not more than once per hour: torque is 36 in.·lb.
■ system pressure 1. Select the base start and base end 2. According to Table 13, the
torque at system pressure from temperature factor is 1.0.
■ system temperature.
Table 12. 3. Start torque = 61 in.·lb × 1.0
2. Select the temperature factor from = 61 in.·lb
Table 13. End torque = 36 in.·lb × 1.0
3. Calculate the start and end operating = 36 in.·lb.
torque: If the valve will be cycled less frequently
Base torque (Table 12) than once per day or more frequently
× temperature factor (Table 13). than once per hour, contact your
authorized Swagelok representative.
Example: AFS valve is operated with
nitrogen at 4500 psig and 70°F (20°C).

Table 12—Base Start and End Torque Table 13—Temperature Factors


Torque values based on the valve’s remaining closed for one Temperature factors based 6000 psig (413 bar) system

BALL VALVE
SELECTION

ACTUATED
day at pressure. Use linear interpolation to obtain torque pressure and on the valve’s remaining closed for one day at
values for system pressures not listed. pressure. Use linear interpolation to obtain factors for system
temperatures not listed.
System Pressure, psig (bar, MPa)
1000 4500 6000 Temperature, °F (°C)
0 (68.9, 6.89) (310, 31.0) (413, 41.3) –40 (–40) 70 (20) 185 (85) 250 (121)
Valve
Torque Base Torque, in.·lb (N·m, cm·kg) 2.9 1.0 1.0 1.0
Start 13 (1.5, 15) 23 (2.6, 27) 61 (6.9, 71) 76 (8.6, 88)
End 12 (1.4, 14) 18 (2.1, 21) 36 (4.1, 42) 41 (4.7, 48)

Ordering Information Mounting Bracket Kit Ordering Numbers


ISO 5211
Flange Coupling Cap Screw Bracket Kit
Size Size Type Ordering Number
11 mm ISO Metric SS-MB-AFS-F05-11ISO-M
11 mm ISO Fractional SS-MB-AFS-F05-11ISO-F
11 mm DIN Metric SS-MB-AFS-F05-11DIN-M
11 mm DIN Fractional SS-MB-AFS-F05-11DIN-F
14 mm ISO Metric SS-MB-AFS-F05-14ISO-M
14 mm ISO Fractional SS-MB-AFS-F05-14ISO-F
F05
14 mm DIN Metric SS-MB-AFS-F05-14DIN-M
14 mm DIN Fractional SS-MB-AFS-F05-14DIN-F
17 mm ISO Metric SS-MB-AFS-F05-17ISO-M
17 mm ISO Fractional SS-MB-AFS-F05-17ISO-F
17 mm DIN Metric SS-MB-AFS-F05-17DIN-M
Swagelok AFS 17 mm DIN Fractional SS-MB-AFS-F05-17DIN-F
ball valve with 17 mm ISO Metric SS-MB-AFS-F07-17ISO-M
ISO 5211-compliant 17 mm ISO Fractional SS-MB-AFS-F07-17ISO-F
actuator. F07
17 mm DIN Metric SS-MB-AFS-F07-17DIN-M
17 mm DIN Fractional SS-MB-AFS-F07-17DIN-F

1. Select the desired AFS valve. Using the Calculating


Operating Torque instructions at right, calculate the valve
start and end torque.
2. Choose an actuator based on the valve start and end
torque. See the actuator manufacturer’s literature to specify
ISO 5211 mounting dimensions, including flange and
coupling sizes.
3. Select a mounting bracket kit ordering number.
See Mounting Instructions, ISO 5211 Dimensionally Compliant
Bracket, Coupling, and Actuator, MS‑INS‑4080‑NAMUR.
10 Ball Valves and Quarter-Turn Plug Valves

SK Series Valves
Operating Torque Calculating Operating Torque 1. According to Table 14, the base start
Operating torque for a Swagelok SK 1. Determine the base start and base torque is 21 in.·lb and the base end
series valve is influenced by: end torque at system pressure from torque is 10 in.·lb.
■ cycle frequency Table 14. 2. According to Table 15, the
2. Determine the temperature factor temperature factor is 1.0.
■ system pressure
from Table 15. 3. Start torque = 21 in.·lb × 1.0
■ system temperature.
3. Calculate the start and end operating = 21 in.·lb
torque: End torque = 10 in.·lb × 1.0
Base torque (Table 14) = 10 in.·lb.
× temperature factor (Table 15). If the valve will be cycled less frequently
Example: SK series valve is operated than once per day or more frequently
with nitrogen at 3000 psig and 70°F than once per hour, contact your
(20°C). authorized Swagelok representative.

Table 14—Base Start and End Torque Table 15—Temperature Factors


Use linear interpolation to obtain torque values for system Use linear interpolation to obtain factors for system
pressures not listed. temperatures not listed.
BALL VALVE
SELECTION
ACTUATED

System Pressure, psig (bar, MPa) Temperature, °F (°C)


0 3000 (206, 20.6) 6000 (413, 41.3) –40 (–40) 0 (–17) 70 (20) 250 (121) 302 (150)
Valve
Torque Base Torque, in.·lb (N·m, cm·kg) 2.0 2.0 1.0 1.0 1.0
Start 14 (1.6, 17) 21 (2.4, 25) 26 (3.0, 30)
End 10 (1.2, 12) 10 (1.2. 12) 10 (1.2. 12)

Ordering Information Mounting Bracket Kit Ordering Numbers


ISO 5211
Flange Coupling Cap Screw Bracket Kit
Size Size Type Ordering Number
11 mm ISO Metric SS-MB-4SK-F04-11ISO-M
11 mm ISO Fractional SS-MB-4SK-F04-11ISO-F
F04
11 mm DIN Metric SS-MB-4SK-F04-11DIN-M
11 mm DIN Fractional SS-MB-4SK-F04-11DIN-F

Swagelok SK
series valve with
ISO 5211-compliant
actuator.

1. Choose an actuator based on the valve start and end


torque. See the actuator manufacturer’s literature to specify
ISO 5211 mounting dimensions, including flange and
coupling sizes.
2. Select a mounting bracket kit ordering number.
See Mounting Instructions, ISO 5211 Dimensionally Compliant
Bracket, Coupling, and Actuator, MS‑INS‑4080‑NAMUR.
Actuated Ball Valve Selection Guide, ISO 5211-Compliant Actuator Mounting Bracket Kits 11

FKB Series Valves


Operating Torque Calculating Operating Torque 1. According to Table 16, the base start
Operating torque for a Swagelok FKB If the valve will be cycled at least once per torque is 256 in.·lb and the base end
series valve is influenced by: day, but not more than once per hour: torque is 63 in.·lb.
■ system pressure 1. Select the base start and base end 2. According to Table 17, the
torque at system pressure from temperature factor is 1.0.
■ system temperature.
Table 16. 3. Start torque = 256 in.·lb × 1.0
2. Select the temperature factor from = 256 in.·lb
Table 17. End torque = 63 in.·lb × 1.0
3. Calculate the start and end operating = 63 in.·lb.
torque: If the valve will be cycled less frequently
Base torque (Table 16) than once per day or more frequently
× temperature factor (Table 17). than once per hour, contact your
authorized Swagelok representative.
Example: 8FKB valve is operated with
nitrogen at 7500 psig and 70°F (20°C).

Table 16—Base Start and End Torque


Torque values based on the valve’s remaining closed for one day at pressure. Use linear interpolation to obtain torque values for

BALL VALVE
system pressures not listed.

SELECTION

ACTUATED
System Pressure, psig (bar, MPa)
0 3750 (258, 25.83) 7500 (516, 51.6) 11 250 (775, 77.5) 15 000 (1034, 103)
Base Torque, in.·lb (N·m, cm·kg)
Valve
Series Start End Start End Start End Start End Start End
6FKB 30 (3.4, 35) 30 (3.4, 35) 51 (5.8, 59) 33 (3.8, 39) 71 (8.1, 82) 35 (4.0, 41) 85 (9.7, 98) 47 (5.4, 55) 102 (12, 118) 49 (5.6, 57)
8FKB 84 (9.5, 97) 71 (8.1, 82) 166 (19, 192) 72 (8.2, 83) 256 (29, 295) 63 (7.2, 73) 322 (37, 371) 64 (7.3, 74) 375 (43, 432) 76 (8.6, 88)
12FKB 288 (33, 332) 184 (21, 212) 308 (35, 355) 140 (16, 162) 396 (45, 257) 145 (17, 168) 443 (51, 511) 121 (14, 140) 543 (62, 626) 116 (14, 134)

Ordering Information Table 17—Temperature Factors


Temperature factors based 6000 psig (413 bar) system
pressure and on the valve’s remaining closed for one day at
pressure. Use linear interpolation to obtain factors for system
temperatures not listed.

Temperature, °F (°C)
Valve
Series 0 (–17) 70 (20) 250 (121)
6FKB 1.5 1.0 1.0
8FKB 1.2 1.0 1.0
12FKB 1.0 1.0 0.6

Swagelok 6FKB Mounting Bracket Kit Ordering Numbers


series valve with
ISO 5211-compliant ISO
actuator.
5211 Cap
Valve Flange Coupling Screw Bracket Kit
1. Select the desired FKB series valve. Using the Calculating Series Size Size Type Ordering Number
Operating Torque instructions above, calculate the valve 6FKB F05 14 mm DIN Metric SS-MB-6FKB-F05-14DIN-M
start and end torque. 8FKB F07 17 mm DIN Metric SS-MB-8FKB-F07-17DIN-M
2. Choose an actuator based on the valve start and end 12FKB F07 17 mm DIN Metric SS-MB-12FKB-F07-17DIN-M
torque. See the actuator manufacturer’s literature for
ISO 5211 mounting dimensions, including flange and
coupling sizes.
3. Select a mounting bracket kit ordering number.
See Medium-Pressure Ball Valve, Mounting Instructions
for FKB Series Medium-Pressure Ball Valves to
ISO 5211-Compliant Actuators, MS‑CRD‑0124.
12 Ball Valves and Quarter-Turn Plug Valves

Mounting Bracket Kits


Kits for Swagelok 40G, 40, 83, H83, SK, and FKB series and Kits for Swagelok 60 series valves contain:
AFS ball valves contain: ■ 316 stainless steel mounting bracket that meets ISO 5211
■ 316 stainless steel mounting bracket that meets ISO 5211 dimensional specifications
dimensional specifications ■ four 316 stainless steel socket head cap screws for
■ four (eight for FKB series valves) 316 stainless steel socket fractional sizes, or A4 stainless steel for metric sizes
head cap screws for fractional sizes, or A4 stainless steel (A4 is approximately equivalent to AISI 316.)
for metric sizes (A4 is approximately equivalent to AISI 316.) ■ 316 stainless steel coupling
■ Coupling ■ 316 stainless steel wall mounting bracket
■ 40G, SK, and FKB series—powdered metal 300 series ■ two 316 stainless steel lock washers
stainless steel
■ 302 stainless steel upper and lower grounding springs
■ 40, 83, and H83 series and AFS ball valves—316
■ 316 stainless steel lock tab
stainless steel
■ two 316 stainless steel hex nuts and bolts
■ A4 stainless steel set screw (316 stainless steel for FKB
series valves) ■ lubricant and MSDS

■ instructions. ■ instructions.
BALL VALVE
SELECTION
ACTUATED

Actuated Ball Valve Assemblies


In addition to bracket kits, Swagelok can provide complete
actuated ball valve assemblies—including valves, actuators, Swagelok-Stocked Components
sensors, and solenoids—with interfaces that meet ISO 5211, Actuators Sensors Solenoids
NAMUR, and VDI/VDE 3845 standards. Swagelok Pepperl+Fuchs ASCO®
Assemblies are based on: (proximity sensors)
■ maximum valve pressure Westlock
■ ambient temperature (50 to 100°F [10 to 37°C]) (limit switches)
■ a design margin of 20 % for calculated operating torque Additional components and manufacturers available on request.

Contact your authorized Swagelok representative for


assemblies built for other system conditions.
See the Swagelok Actuation Options for Swagelok Ball Valves
catalog (MS‑02‑343) for more information.

• Caution: Actuated assemblies must be properly


aligned and supported. Improper alignment or
inadequate support of the actuated assembly may
result in leakage or premature valve failure.

Caution: Do not mix or interchange valve components


with those of other manufacturers.
MS-02-136, R6, October 2017
About this document
Thank you for downloading this electronic catalog, which is part of General Product
catalog Swagelok published in print. This type of electronic catalog is updated as new
information arises or revisions, which may be more current than the printed version.
Swagelok Company is a major developer and provider of fluid system solutions,
including products, integration solutions and services for industry research,
instrumentation, pharmaceutical, oil and gas, power, petrochemical, alternative fuels,
and semiconductor. Our manufacturing facilities, research, service and distribution
facilities support a global network of more than 200 authorized sales and service
centers in 57 countries.
Visit www.swagelok.com to locate your Swagelok representative and obtain any
information on features, technical information and product references, or to learn about
the variety of services available only through authorized sales centers and service
Swagelok.

Safe Product Selection


Warranty Information
When selecting a product, the total system design must be Swagelok products are backed by The Swagelok Limited
considered to ensure safe, trouble-free performance. Function, Lifetime Warranty. For a copy, visit your Swagelok Web site or
material compatibility, adequate ratings, proper installation, contact your authorized Swagelok representative.
operation, and maintenance are the responsibilities of the system
designer and user.

Swagelok, Ferrule-Pak, Goop, Hinging-Colleting, IGC, Kenmac,


Micro-Fit, Nupro, Snoop, Sno-Trik, SWAK, VCO, VCR, Ultra-
Torr, Whitey—TM Swagelok Company
Aflas—TM Asahi Glass Co. Ltd.
AL-6XN—TM Allegheny Ludlum Corporation
AutoCAD—TM Autodesk, Inc.
CSA—TM Canadian Standards Association
DeviceNet—TM ODVA
Kalrez, Krytox—TM DuPont
Elgiloy—TM Elgiloy Specialty Metals
FM —TM FM Global
Grafoil—TM GrafTech International Holdings, Inc.
MAC—TM MAC Valves Inc.
Microsoft, Windows—TM Microsoft Corp.
NACE—TM NACE International
Nitronic—TM AK Steel Corporation
picofast—TM HansTurck KG
Pillar—TM Nippon Pillar Packing Company, Ltd.
Rapid Tap—TM Relton Corporation
15-7 PH, 17-7 PH—TM AK Steel Corp.
Sandvik—TM SandvikAB
Silconert—TM Silcotek Corporation
Simriz—TM Freudenberg-NOK
SolidWorks—TM SolidWorks Corporation
© 2017 Swagelok Company

You might also like