Roof Sheeting Profile:: General Notes
Roof Sheeting Profile:: General Notes
GENERAL NOTES:
333.3 333.3 333.3
Kingspan QuadCore® KS1000RW Roof Stitching screws with min
ALL DIMENSIONS AND AREA'S ARE TO BE CHECKED AND VERIFIED ON SITE ANY 27
16.1 30.5 16.1 30.5 Panel, 120mm core insulation thickness, 14mm Ø non ferrous EPDM
DISCREPANCIES ARE TO BE REPORTED BACK TO GUIDING LIGHT ARCHITECTURE FOR
55 50.5 Overall Panel thickness = 151mm, backed washer fitted at max
DRAWING AMENDMENTS.
38.
450mm ctrs and 20 x 3mm
16
5° Colour: Goosewing Grey RAL 080 70
20
ALL DIMENSIONS FOR DOOR AND WINDOW OPENINGS ARE SHOWN TO STRUCTURAL 5°
65
35
11 11 05, BS 10A05. butyl rubber sealant.
°
OPENINGS AND DO NOT INCLUDE FOR ANY EXTERNAL OR INTERNAL FINISHES SUCH 115° 110 Verge flashing, double sided
Panel Thickness
° All roofing panels fixed back to cold
AS RENDERS OR PLASTERBOARDS. plastisol with 150mm sealed Any gaps to be filled with fire
rolled secondary steel. rated canister insulation.
butt straps.
THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH ALL OTHER DRAWING NO'S
Self-drilling, self tapping
STARTING WITH THE PREFIX No: 2404-157.
75
Low profile stitching screws primary fixings witn minimum
°
and buytl sealant as required 19mm Ø non-ferrous EPDM
FOR ALL FOUNDATIONS, GROUND FLOOR SLABS & STRUCTURAL DETAILS AND DESIGN 33 32.8
by the sheeting manufacturer. backed washer @ max
1
PLEASE REFER TO DRAWINGS AND DOCUMENTS PROVIDED BY THE STRUCTURAL 12 1000mm ctrs.
ENGINEER. PLEASE NOTE DUE TO BOUNDARY CONDITIONS IN RELATION TO FIRE
SPREAD, THE FRAME MUST BE DESIGNED TO SCI PUBLICATION P313. All structural steelwork to be
Ayrshire Metals Z17020 cold specified by structural engineer. Cold rolled cleader angle
by steel sub-contractor with
FOR ALL GROUND LEVELS AND BELOW GROUND DRAINAGE PLEASE REFER TO
DRAWINGS AND DOCUMENTS PROVIDED BY THE CIVIL'S ENGINEER.
ROOF SHEETING PROFILE: (1:5) rolled purlins @1200mm ctrs
with sleeves, struts, bracing etc
Steel fabrication and erection is
to be carried out by a specialist air seal - Vapourflex
sub-contractor. sealant applied at joints.
to manufacturers specification.
FOR MECHANICAL & ELECTRICAL INFORMATION PLEASE REFER TO DRAWINGS AND
DOCUMENTS PROVIDED BY M&E CONSULTANTS, TO INCLUDE BOILER & MECHANICAL Kingspan Quadcore AWP Insulated
EXTRACT (mef) POSITIONS (I.E FLOOR OR WALL MOUNTED). wall panels, horizontally laid, 100mm
core insulation thickness.
All fixings, butyl rubber sealant and
air seals all to manufacturers details.
1 2
13/01
8700
tran tran
sluc sluc
ent e nt ro
roof oflig
light ht
5700
tran tran
sluc sluc
ent e nt ro
roof oflig
light ht
Date
Revision
Drawn
Checked
Approved
Description
Revisions
tran tran
sluc sluc
ent e nt ro 0 100
roof oflig
light ht This drawing may have been reduced original scale : 100mm
This drawing is the copyright of Guiding Light Architecture Ltd in accordance with
Section 16 of the Copyright Designs & Patents Act 1988, and cannot be reproduced
in part or whole without prior written consent and is not available for third party use.
5700
TENDER ISSUE
tran tran
sluc sluc
ent e nt ro
roof oflig
light ht Scale Drawn Checked Approved
CAD Ref -
13/01
GUIDING LIGHT ARCHITECTURE LTD
Moreton Area Centre, High Street, Moreton in Marsh, Gloucestershire, GL56 0AZ