Setaflash Small Scale
Flash Point Testing
Setaflash® Series 3
The safest choice
Approved in over 1000 international product
specifications and regulations
∞ ISO 3679; ISO 3680 (obs); ISO 9038
∞ ASTM D3278; D3828; D4206; D7236; D8174; EPA 1020 B&C; SW-846
∞ IP 523; 524; 534; 602; BS 2000-523
1 minute test ∞ 2 ml sample ∞ 0 to 300 °C ∞ Portable ∞ Precise
Stanhope-Seta, London Street, Chertsey, Surrey, KT16 8AP, UK
t: +44 (0) 1932 564391 | e: [email protected] | www.stanhope-seta.co.uk
Setaflash Small Scale
Flash Point Testing
Why use Setaflash Series 3?
∞ Conforms to international regulations
∞ 1 or 2 minutes test time
∞ 2 ml sample
∞ 10 to 135 °C or ambient to 300 °C
Key features
∞ Compact, portable and rugged design
∞ Best published precision of any flash point method
∞ Suitable for unknown samples using ramp mode
∞ Automated flash detection
∞ Automatic barometric pressure correction
∞ USB port and result storage
∞ Electric ignitor or gas (model dependant)
∞ Low cost of purchase and maintenance
Where can I find more information?
Learn more about flash point testing:
www.stanhope-seta.co.uk/flash-point-testing-explained
Operator sequence
4 easy steps:
Select test temperature Inject 2ml sample Press Dip the ignitor, flash
detection is automatic
Stanhope-Seta, London Street, Chertsey, Surrey, KT16 8AP, UK
t: +44 (0) 1932 564391 | e: [email protected] | www.stanhope-seta.co.uk
Setaflash Small Scale
Flash Point Testing
Trusted Precision and Accuracy USB Data Transfer
∞ The most precise flash point test ∞ 1 GB data capacity, holding
∞ Proven performance 100,000 results
∞ Approved in an extensive range of ∞ Results can be saved to a
specifications and regulations USB stick
5.0
4.5
4.0
3.5
Calibration and Verification
Temperature ˚ C
3.0 ASTM D7236
Reproducability (R)
2.5 ∞ Software enables the user to calibrate
2.0
temperature and barometric pressure
1.5 ASTM D7326 ∞ Verification through Seta’s Small Scale
Repeatability (r)
1.0 Certified Flash Point material (reference
0.5 99878-3)
0.0
40 60 80 1001 0120 135
Temperature ˚C
Small Sample - 2 ml Service and Maintenance
∞ Small sample size of only 2 ml ∞ Rugged design
∞ Reduces costs and waste per test ∞ Minimum maintenance
Technical Specifications:
Seta Part 30000-3 30020-0 33200-3, 33250-3 33220-0, 33270-0
Number:
Rapid Results in just 1 Cup: Closed Closed Closed Closed
or 2 Minutes Aluminium or stainless Aluminium or stainless
Material: Aluminium Aluminium steel insert steel insert
∞ Fastest method of checking Ignitor: Gas Electric Gas Electric
flash point Temperature Ambient to 300 °C Ambient to 300 °C 10 to 135 °C 10 to 135 °C
Range:
∞ Results determined in just Automatic or custom Automatic or custom Automatic or custom Automatic or custom
settings (ramp rate: up settings (ramp rate: up settings (ramp rate: up settings (ramp rate: up
one or two minutes to 6 °C/min and beep to 6 °C/min and beep to 6 °C/min and beep to 6 °C/min and beep
Temperature rate: up to 5 °C/B rate: up to 5 °C/B rate: up to 5 °C/B rate: up to 5 °C/B
Ramp Mode: intervals) Extended intervals) Extended intervals) Extended intervals) Extended
∞ Maximises operability test range, 100 °C test range, 100 °C test range, 100 °C test range, 100 °C
from start temperature from start temperature from start temperature from start temperature
Temperature °C or °F °C or °F °C or °F °C or °F
Selection:
Colour LCD display - Colour LCD display - Colour LCD display - Colour LCD display -
User Interface: touch screen sensitive touch screen sensitive touch screen sensitive touch screen sensitive
Control knob Control knob Control knob Control knob
Navigation: (rotational and push- (rotational and push- (rotational and push- (rotational and push-
down) down) down) down)
Search for the Flash 1 GB (internal memory 1 GB (internal memory 1 GB (internal memory 1 GB (internal memory
˚C/min Point Data Storage
and Download: and integrated USB and integrated USB and integrated USB and integrated USB
port) port) port) port)
Sample Size: 2 ml or 4 ml 2 ml or 4 ml 2 ml or 4 ml 2 ml or 4 ml
∞ Test unknown samples
using ramp mode Pressure
Correction:
Automatic barometric
correction
Automatic barometric
correction
Automatic barometric
correction
Automatic barometric
correction
∞ User adjustable ramp rates & Voltage Supply:
110 to 250 V
a.c~50/60 Hz
110 to 250 V
a.c~50/60 Hz
110 to 250 V
a.c~50/60 Hz
110 to 250 V
a.c~50/60 Hz
dip interval (universal) (universal) (universal) (universal)
Power: 200 W (Max.) 200 W (Max.) 200 W (Max,) 200 W (Max,)
Size (HxWxD) / 19.5 x 29.5 x 14 cm 19.5 x 29.5 x 14 cm 19.5 x 29.5 x 14 cm 19.5 x 29.5 x 14 cm
Weight: / 3 kg / 3 kg / 3 kg / 3 kg
Stanhope-Seta, London Street, Chertsey, Surrey, KT16 8AP, UK
t: +44 (0) 1932 564391 | e: [email protected] | www.stanhope-seta.co.uk
Setaflash Small Scale
Flash Point Testing
Products & Specifications
Diesel | Aviation Fuel | Marine Fuel | Biodiesel | FAME | Chemicals | Pharmaceuticals | Paints | Cosmetics | Waste
Flavours | Inks | Waxes | Adhesives | Oils - Lubricating, Hydraulic, Base, Mineral, Used/Cooking Oils | Pastes
Applications
Application: Test Method: Who Says So:
QC Transport
Regulation
Small Scale, other
Closed Cups
UN GHS; IATA; ADR;
IMDG; CLP; DOT
CFR 49-173.120
ASTM D1655; Def
Transport & Storage
Quality Control Regulations
Aviation Turbine Small Scale, Abel, Stan 91-91; IATA
Fuel Tag, Pensky-Martens Guidance Material;
ATA 103; AFQRJOS
Small Scale, Pensky-
Gas Turbine Fuel ASTM 2880
Martens
Small Scale, Pensky-
Diesel Fuel ASTM D975; D7467
Martens
Waste Disposal Kerosines Small Scale, Tag ASTM D3699
CLP Regulations Regulations EN14213; EN14214;
Biodiesel Small Scale
ASTM D6751
Small Scale, Pensky- ASTM D396;
“For us the Setaflash Tester is a valuable piece of kit Fuel Oil
Martens A&B ISO 8217
and we’d struggle without it. Our main use is to detect
Naphthas Small Scale, Tag ASTM D3734; D3735
whether a waste is hazardous or not, as this can have
knock on effects in terms of cost, safety, compliance OSHA 29 CFR
and potential processing routes. It’s very useful to Health & Safety Small Scale
1910.106 & 1200;
have it at hand as sending samples out for off site CPSC CFR 16-1500
analysis simply would not be an option at times, due 43a
to potentially lengthy turn around times.” Water Borne Paints Small Scale ISO 3679; ISO 3680
Nick Richardson,
Laboratory Supervisor, Castle Environmental EPA 1020 B; CFR40
Waste Products Small Scale 261.21; ASTM D8174;
2008/98/EC
Discover the entire Setaflash Range
Seta Model: Seta Part Temperature Ignitor: Heating/Cooling
No: Range: Method:
Ambient to 300 °C *(0 to 300 °C
Series 3 Closed Cup 30000-3 Gas Cartridge Heater
with coolant module)
Ambient to 300 °C *(0 to 300 °C
Series 3 Open Cup 31000-0 Gas Cartridge Heater
with coolant module)
Ambient to 300 °C *(0 to 300 °C
Series 3e Closed Cup 30020-0 Electric Cartridge Heater
with coolant module)
Series 3 Activecool 33200-3 10 to 135 °C Gas Peltier Cell
Series 3 Activecool
33250-3 10 to 135 °C Gas Peltier Cell
(Corrosion Resistant)
Series 3e ActiveCool 33220-0 10 to 135 °C Electric Peltier Cell
> 30000-3
Series 3e ActiveCool
33270-0 10 to 135 °C Electric Peltier Cell
(Corrosion Resistant)
Ceramic Pad, Forced Air (post-
Series 8 High Temperature 82000-2 Ambient +5 to 300 °C Electric
test cool down)
Ceramic Pad, Forced Air (post-
Series 8 High Temperature 82050-2 Ambient +5 to 300 °C Gas
test cool down)
Series 8 Activecool 82100-2 -30 to 135 °C Electric Peltier cell
Series 8 Activecool 82110-2 -30 to 135 °C Gas Peltier cell
Series 8 Activecool
82150-2 -30 to 135 °C Electric Peltier cell
(Corrosion Resistant)
Series 8 Activecool
82160-2 -30 to 135 °C Gas Peltier cell
(Corrosion Resistant)
> 82100-2
For more information please visit: www.stanhope-seta.co.uk
Stanhope-Seta, London Street, Chertsey, Surrey, KT16 8AP, UK
t: +44 (0) 1932 564391 | e: [email protected] | www.stanhope-seta.co.uk | Issue 5