16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

This drawing is the property of SOJITZ-L&T CONSORTIUM and must not be passed on to
any person or body not authorised by us to receive it nor be copied or otherwise made use
either in full or in part by such person or body without our prior permission in writing.

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES, LEVELS &
M CHAINAGES ARE IN METRES UNLESS OTHERWISE M
e2 * SPECIFIED.

2. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN


DIMENSIONS SHALL BE FOLLOWED.

3. DESIGN CRITERIA.
i) IRS BRIDGE RULES INCORPORATING A&C SLIP NO.42

1000 FOR TYPE-B


ii) IRS CONCRETE BRIDGE CODE INCORPORATING A&C

900 FOR TYPE-A


SLIP NO.13
iiI) IRS BRIDGE SUBSTRUCTURE & FOUNDATION CODE
INCORPORATING A&C SLIP NO.29

4d
4. BACK FILL MATERIAL CONSIST OF GRANULAR
MATERIAL OF GW, GP, SW GROUPS AS PER IS:

4d
2000
1498-1970.
L L
5. SUBWAY SHALL BE DESIGNED AS PER DFCCIL

2000
LOADING (32.5T AXLE LOAD) AS PER BRIDGE RULES
ISSUED BY RDSO (WITH LATEST CORRECTION SLIP).

6. GRADE CONCRETE FOR PRECAST BOX AND SECOND


STAGE POURING CONCRETE FOR TOP SLAB AND
RETAINING WALL SHALL BE M30.
Z
7. ALL RCC SURFACES COMING IN CONTACT WITH SOIL
SHOULD BE PAINTED WITH BITUMEN OR COAL TAR
OF APPROVED QUALITY @ 1.464 KG/SQM.
Ld
S1
8. ALL DIMENSIONS SHALL BE VERIFIED AND
X X RECONCILED BEFORE EXECUTION.

Ld

Ld
L2 L1 9. TOLERANCE SHALL BE FOLLOWED AS PER IRS
K K
CONCRETE BRIDGE CODE.
h1

10.
DESIGN DOCUMENT NO:DOC/CTP1&2/DGN/BR/0351.

Ld
PER GIR DOC NO. DOC/CTP2/DGN/GB/0203 PART 1c .
SPT N VALUE OF THE BORE LOG HAS TO BE
VERIFIED AT THE BOTTOM LEVEL OF EXCAVATION
ON THE NATURAL GROUND . IF NOT ACHIEVED,
FURTHER EXCAVATION SHOULD BE DONE TO GET
THE REQUIRED SPT N VALUE.

11. FOR TYPICAL STRUCTURAL DETAILS OF MANHOLE,


* SUMP & DUCT DRAIN REFER SEPARATE DRAWING.

12. FOR TYPICAL STRUCTURAL DETAILS OF STEEL ROOF


J ** FOR RAMP PORTION REFER SEPARATE DRAWING. J

13. THIS DRAWING SHALL BE READ IN CONJUNCTION


WITH FOLLOWING DRAWINGS.
1-2-PS-GEN-000-5252 MISCELLANEOUS DETAILS FOR
** PS1-MB-GEN-000-4900 & 4901 GENERAL NOTES.

14. ALL DIMENSIONS INCLUDING DISTANCE FROM IR


TRACK & LEVELS SHOULD BE VERIFIED WITH
ALIGNMENT DRAWING AND AT SITE BEFORE
EXECUTION.
h2

15. EMBANKMENT FILLING ON BOTH SIDES OF BOX SHALL


BE IN LAYERS AND THE SAME SHALL BE CARRIED
b e1 c 12 9 OUT SIMULTANEOUSLY ON BOTH SIDES. BACKFILL
50 SHALL NOT BE PLACED UNTIL THE TOP SLAB IS CAST
H (TYP.) IN CASE OF CAST-IN-SITU CONSTRUCTION. H

16. REFER SEPARATE DRAWING FOR DETAILS OF


U-SHAPE WALL/SECTION & RCC RETAINING WALL.
d1

17. LIGHTING SHALL BE PROVIDED AS PER ER.


d2

18. HANDRAIL SHALL TO BE PROVIDED IN RAMPS


THROUGHOUT ITS WHOLE LENGTH AT BOTH ENDS.

100 a
(TYP.)
11 10
ABBREVATIONS
G C
L - CENTER LINE INVERT LEVEL OF G
REV - REVISION MANHOLES

* TYP - TYPICAL
THK. - THICKNESS MH1 - 264.724
** MH2 - 264.582
BH - BORE HOLE

THIS DRAWING IS BASED ON PLAN & PROFILE


DRAWING NO: 2-AL-CHD-0001. REV-0

F F

FOR DESIGN DETAILS REFER DOCUMENT


NO:DOC/CTP1&2/DGN/BR/0351

VARIES

VARIES
E E

D D

VARIES

VARIES
ISSUED FOR CONSTRUCTION
0
DESIGN PACKAGE JAY 23.12.17 SKV 23.12.17 JAY 23.12.17 VR 23.12.17
REV.NO. DESCRIPTION DESIGNED DRAWN CHECKED APPROVED

C REVISIONS C
PROJECT :
WESTERN DEDICATED FREIGHT CORRIDOR
PACKAGE CT P1 & P2 – Rewari to Iqbalgadh
ORGANIZATION SEAL & SIGN.
EMPLOYER :
DEDICATED FREIGHT
CORRIDOR CORPORATION OF
INDIA LTD.

CONTRACTOR :

SOJITZ-L&T CONSORTIUM

B DESIGNER: B

L&T INFRASTRUCTURE
ENGINEERING LIMITED

TITLE: PEDESTRIAN SUBWAY AT


DFC CH.22+200.025, SECTON-11
GENERAL ARRANGEMENT DETAILS OF PEDESTRIAN
VARIES

VARIES

SUBWAY (1x6.0x3.6) (MARWAR JUNCTON)


JOB No : O13108 SIZE RELEASED FOR
A1 PRELIMINARY
NAME SIGN DATE
PROJECTION
INFORMATION
DSGN ANIL GUPTA 06.06.14

DRWN DEVANAND 06.06.14 APPROVAL


A FIRST ANGLE A
CHKD A. VAIDYA 06.06.14 SCALE CONSTRUCTION

APPD S. SHRIVASTAVA 06.06.14 AS SHOWN ASBUILT

DRG. No: REV

2 P S 1 3 - 0 0 1 0 6 7 6 0
SHEET NO.: 3 OF 3

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1